Technical Guide DESCRIPTION SPLIT-SYSTEM EVAPORATOR BLOWER L4EU NOMINAL TONS FEATURES YTG-A-0307

Similar documents
VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

INDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

DESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System

MAC-120HE-01 Air-Cooled Chiller

INDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

INDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

TWE+TTA TWE+TWA T.R.

INDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES

Cooling/Heat Pump Convertible Air Handlers

Cased/Uncased Coils For Gas And Oil Furnaces

Element D Services Heating, Ventilating, and Air Conditioning

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

Commercial Gas Furnace Upflow

ENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical

Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO

SPLIT-SYSTEM CONDENSING UNITS SEER HRA018 thru 060 (1.5 thru 5 Nominal Tons) DESCRIPTION FEATURES

ROOF TOP MOUNTED Air Handler Specification

Installation Manual CLIFC Fan & Coil Variable Speed

Installation Instructions

Cooling Capacity CFM in. w.c. (125 Pa)

Cooling Capacity CFM in. w.c. (125 Pa)

ARMSTRONG AIR HEAT PUMPS

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Greensource iseries HY Model Unitary Air Handler/Fan Coil

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

catalog Single Package Vertical Air Conditioners and Heat Pumps

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

COIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.

Split System Heat Pump Product Data

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

How To Install An Evaporator Coil

Low Profile Unit Cooler

F9MXE. Product Specifications

Packaged Cooling with Electric Heat Rooftop Units

DESIGN STANDARDS SECTION

Split System Heat Pump Product Data

University of Houston Master Construction Specifications Insert Project Name

Split System Cooling Product Data

SECTION MORTUARY REFRIGERATORS

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

WMSLW / WMBLWH Series Hydronic Upflow/Horizontal Left or Right, Heating and Cooling Air Handler

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

Split System Cooling Product Data

Installer s Guide 18-AH39D1-13

AIR-COOLED CONDENSERS Technical Guide

CE6500 Energy Recovery Ventilator

SECTION AIR CONDITIONING UNIT

Cooling Capacity CFM in. w.c. (125 Pa)

RHF High Efficiency Remote Heat Pumps and Matching Blower Coils

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

G9MXE. Product Specifications

CB29M Bulletin # February 1996

Packaged Gas/Electric Rooftop Units

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Product Data. Split System Cooling F-EN. March 2015

Installation Instructions

Product Data. FV4C Performancet Series Fan Coil Sizes 002 Thru 006 PREMIUM ENVIRONMENTALLY SOUND FAN COIL

GCS16 GCS20 WARNING CAUTION

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Heating Ventilation and Air Conditioning Diagnostics for Single Family Homes

E2 Series Electric Furnaces

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

WATER-COOLED VERTICAL PACKAGED AIR CONDITIONERS 5-Ton through 30-Ton Capacity

LOBOY 16 AIR CONDITIONERS

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Glossary of Heating, Ventilation and Air Conditioning Terms

Evaporator Coil Installation Instructions

TECHNICAL MANUAL GDS8 & GHS8

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

Split System Cooling Product Data

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

1932 Lexington Houston, Texas (713) Recommendations for installation of cooling systems

Chilled Water HVAC Systems

INSTALLATION INSTRUCTIONS Fan Coil Replacement Coil Kit EBX & EBXX

Horizontal Jet Pumps 1/3-1-1/2 HP

Air-Cooled Condensers

SECTION A. Horsepower: Do not increase or decrease fan motor horsepower without written approval from Engineer.

Johnson Air-Rotation Systems

Fan Applications & System Guide

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

Defining Quality. Building Comfort. Heating and Cooling Coils

Centrifugal Fans and Pumps are sized to meet the maximum

AABC Specifications for Testing and Balancing HVAC Systems

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

"EC" Series Electric Humidifier

PRODUCT CATALOG. Indoor Units

Chilled Water Fan Coil Unit

300 Series PA Pump and Cooler Assemblies

LSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS

HVAC Simplified Approach Option

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

REGULATORS 175/153 Series

Transcription:

DESCRIPTION Technical Guide SPLIT-SYSTEM EVAPORATOR BLOWER L4EU240 20 NOMINAL TONS This 20 ton evaporator blower is designed with two distinct modules to provide maximum application flexibility. The units are shipped as single packages with the blower module mounted on top of the coil module, but the blower module can be repositioned in the field to meet almost any installation requirement. The blower module includes the blower wheels and room for a fieldmounted motor and drive. The coil module includes direct expansion coils, one-inch throwaway filters, 1 liquid line solenoid valve for 50% capacity reduction, thermal expansion valves, distributors and a condensate drain pan. Each evaporator coil is pressurized with air to 325 psig and leak tested under water. After the headers are brazed onto the coil and the coil is installed in the unit, the coil will be pressurized with a combination of refrigerant-22 and nitrogen to 150 psig for pressure testing and additional leak testing. After the coil is evacuated and dehydrated, it will be pressurized with a holding charge of Refrigerant-22 for storage and/or shipping. A supply air plenum, return air grille, steam coil, hot water coil, base section, suspension hardware, blower motors and drive accessories are available for field-installation to provide additional application flexibility. This evaporator blower, applied with a matching condensing unit, will provide years of quiet, efficient and dependable operation. FEATURES APPLICATION FLEXIBILITY - This evaporator blower can be arranged for a variety of air discharge patterns in either the horizontal or the vertical position. The following illustration shows three of the more common installation arrangements. Refer to the unit installation instruction for other possibilities. The unit can be bottom-supported or ceiling-suspended and can be arranged to meet almost any space or duct requirements. Each unit is available with a choice of blower motors, drive packages plus other accessories to make them suitable for most applications. PART LOAD OPERATION - The unit requires no field modifications for part load operation. Capacity reduction not only provides economical operation but also maintains more even temperature and humidity levels in the conditioned space. FOR DISTRIBUTION USE ONLY - NOT TO BE USED AT POINT OF RETAIL SALE

TABLE OF CONTENTS DESCRIPTION................................... 1 FEATURES..................................... 1 ACCESSORIES.................................. 3 ACCESSORY DIMENSIONS........................ 8 LIST OF FIGURES Fig. # Pg. # 1 AIR FLOW PERFORMANCE................... 5 2 UNIT DIMENSIONS.......................... 7 3 SUPPLY AIR PLENUM - MODEL 1SP0405........ 8 4 RETURN AIR GRILLE - MODEL 1RG0405........ 8 5 BASE SECTION* - MODEL 1BS0405............. 8 6 HOT WATER COIL* - MODEL 1HW0405.......... 9 7 STEAM COIL* - MODEL 1NF0453............... 9 8 SUSPENSION KIT - MODEL 1HH0451........... 9 LIST OF TABLES Tbl. # Pg. # 1 PHYSICAL DATA - UNIT AND ACCESSORIES.... 4 2 ELECTRICAL DATA.......................... 4 3 SUPPLY AIR BLOWER PERFORMANCE......... 5 4 BLOWER MOTOR AND DRIVE DATA............ 6 5 HOT WATER CAPACITY, MBH................. 6 6 STEAM COIL CAPACITY, MBH @ 2 PSIG........ 6 7 ACCESSORY STATIC RESISTANCE (IWG)....... 6 8 PLENUM PERFORMANCE.................... 6 PRODUCT NOMENCLATURE L 4 E U 2 4 0 A PRODUCT CATEGORY L = Split-system Evaporator Blower FACTORY INSTALLED HEAT A = Cooling Only PRODUCT GENERATION 4 = 4TH Generation PRODUCT IDENTIFIER NOMINAL COOLING CAPACITY 240 = 20 Tons EU = Evaporator Blower Unit 2 Unitary Products Group

ACCESSORIES RETURN AIR GRILLE - This decorative, expanded metal grille will enhance the appearance of any unit that has no return air ductwork and is especially recommended for units located within the conditioned space. SUPPLY AIR PLENUM - This decorative, horizontal discharge plenum will enhance the appearance and performance of any unit that does not have supply air ductwork. It has the same durable finish as the evaporator blower, is fully insulated, is shipped ready for mounting on horizontal or vertical units and has grilles which may be adjusted to meet the throw and spread requirements of the conditioned space. BASE SECTION - The base section can be used to elevate units off the floor. If desired, outdoor air may be introduced thru these sections by cutting an access opening to accommodate the outdoor air duct connection. The base has a durable finish to match the evaporator blower unit. It may have to be insulated for certain applications. SUSPENSION PACKAGE - This accessory can be used to suspend horizontal units from above without interfering with access to the unit. It can also be used for elevating a floormounted unit (either horizontal or vertical) to provide additional height for the installation of a trap at the condensate drain connection. A suspension package can be used with vibration isolators. HOT WATER COIL - A drainable water coil is available for field installation between the blower and the coil modules of both horizontal and vertical units. Since their casings match the dimensions and the finish of the basic units, they become an integral part of the unit after installation. The coil slides out of its casing for easy installation. The coil has copper tubes that have been mechanically expanded into aluminum fins. Both headers are located on the same end of the coil. Each coil is leak-tested at 325 psig under water and dried before their connections are capped for storage and shipping. STEAM COIL - A steam coil is available for field installation between the blower and coil modules of both horizontal and vertical units. Since their casings match the dimensions and the finish of the basic units, they become an integral part of the unit after installation. The coil slides out of its casing for easy installation and is pitched in its casing to facilitate condensate drainage. The coil has copper tubes that have been mechanically expanded into aluminum fins. Both headers are located on the same end of the coil. Each coil is leak-tested at 325 psig and dried before their connections are capped for storage and shipping. BLOWER MOTORS - Different HP motors are available to meet almost any air delivery requirement. All motors are UL approved, have inherent protection, permanently lubricated ball bearings and get field-mounted within the insulated cabinet of the unit to minimize the transmission of sound to the surrounding space. Power wiring for the blower motor is field supplied. DRIVE PACKAGES - Different size pulleys and belts are available to provide a blower RPM range to meet almost any air delivery requirement. Variable pitch motor pulleys can be adjusted to provide the proper blower RPM. All drive packages are rated at least 25% above the nominal HP rating of the blower motor. Two-groove pulleys and two belts are provided on every drive package rated at 5 HP. Unitary Products Group 3

TABLE 1: PHYSICAL DATA - UNIT AND ACCESSORIES Model Component Description 240 Rows Deep 3 Rows High 32 Evaporator Coil Finned Length (in.) 82.7 Fins / Inch 13 Tube OD (in.) 3/8 Face Area (sq. ft.) 18.4 Centrifugal Blowers Wheel Dia. x Width (in.) (2 Per Unit) 15 x 12 Filters (Throwaway) Size (in.) 20 x 22 x 1 (8 Req d) Face Area (sq. ft.) 24.1 Operating Charge Refrigerant-22 Lbs.-Oz. 7.4 Drainable, Hot Water Coil Accessory Non-Freeze, Steam Distributing Coil Accessory Weight (Lbs.) Accessory Operating Weight (Lbs.) 1. Less Motor and Drive. Rows Deep 2 Fins / Inch 8 Tube OD (in.) 1/2 Face Area (sq. ft.) 14.5 Supply/Return (Copper) OD (in.) 1-3/8 Rows Deep 1 Fins / Inch 8 Tube OD x ID (in.) 1 x 5/8 Face Area (sq. ft.) 13.5 Inlet/Outlet (Brass) NPTE (in.) 1-1/2 Shipping 1 690 Operating 800 Motor & Drive 3 HP 90 5 HP 120 Supply Air Plenum 150 Base 120 Return Air Grille 15 Steam Coil 150 Hot Water Coil 150 3 TABLE 2: ELECTRICAL DATA Motor Rating 3 HP 5 HP Power Supply Nameplate Amps MCA Max. Fuse 1 / Breaker 2 Size (Amps) 208-3-60 10.6 13.3 20 230-3-60 9.2 11.5 15 460-3-60 4.6 5.8 8 208-3-60 13.6 17 25 230-3-60 13.4 16.8 25 460-3-60 6.7 8.4 12 1. Dual element, time delay fuses. 2. HACR type per NEC. 4 Unitary Products Group

TABLE 3: SUPPLY AIR BLOWER PERFORMANCE* CFM RPM 6400 7200 8000 8800 9600 ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW ESP BHP KW 600 0.15 1.49 1.42 - - - - - - - - - - - - 650 0.31 1.71 1.63 0.14 2.00 1.90 - - - - - - - - - 700 0.49 1.95 1.86 0.32 2.27 2.16 0.12 2.63 2.50 - - - - - - 750 0.67 2.21 2.10 0.51 2.56 2.44 0.32 2.92 2.78 0.10 3.35 3.19 - - - 800 0.85 2.50 2.38 0.70 2.85 2.71 0.52 3.25 3.09 0.31 3.70 3.52 0.07 4.20 4.00 850 1.05 2.80 2.66 0.91 3.19 3.04 0.74 3.61 3.44 0.53 4.07 3.87 0.29 4.62 4.40 900 1.25 3.11 2.96 1.12 3.55 3.38 0.96 3.99 3.80 0.76 4.51 4.29 0.53 5.07 4.82 950 1.46 3.46 3.29 1.34 3.92 3.73 1.18 4.43 4.22 1.00 4.97 4.73 0.78 5.53 5.26 1000 1.67 3.82 3.64 1.56 4.33 4.12 1.42 4.88 4.64 1.24 5.44 5.18 - - - Total External Static Pressure WC" 2 1.8 1.6 1.4 1.2 1 0.8 0.6 0.4 0.2 0 FIGURE 1 - AIR FLOW PERFORMANCE LEU 240 AIR FLOW PERFORMANCE 600RPM 1000RPM 950RPM 900RPM 850RPM 800RPM 750RPM 700RPM 650RPM 2 HP * When determining required brake horsepower, select nearest HP to the right of selected CFM. Horsepower ratings on the Airflow Chart are approximate values. To assure correct BHP, please refer to Supply air Blower Performance chart. 3 HP 4 HP 5 HP 6400 7200 8000 8800 9600 Cubic Feet Per Minute (CFM) Unitary Products Group 5

TABLE 4: BLOWER MOTOR AND DRIVE DATA Drive Accessory Model No. Motor Blower Pulley Motor Pulley Belt RPM Range HP 1 Frame Shaft Size Mfgs. No. Size Mfgs. No. Size 1LD0404 600-775 3 56 7/8 A55 AK104 10 x 1-3/16 1VM50 3.4-4.4 x 7/8 1LD0406 775-970 5 184 1-1/8 A57 2 AK114 11 x 1-3/16 2VP71 5.2-6.2 x 1-1/8 1. All motors are 1750 RPM and have a 1.15 service factor. 2. Two matched belts. TABLE 5: HOT WATER CAPACITY 1, MBH Hot Water Coil Accessory Unit Model GPM CFM 1HW0405 240 35 1. These capacities do no include any blower motor heat. NOTE: Water Temperature Drop ( F) = 2 x MBH / GPM. Entering Water Temp. Minus Entering Air Temp., F 70 90 110 130 150 6400 179 229 280 331 382 8000 199 255 312 369 425 9600 220 282 344 407 469 Hot Water Coil Accessory 1HW0405 GPM Pressure Drop 1 PSI Capacity Correction Factory 15 0.2 0.74 35 0.8 1.00 55 1.5 1.04 75 2.5 1.06 1. For pressure drop in feet (water), multiply these values by 2.31. CAUTION: Do NOT operate a supply air blower motor above its nominal HP rating when a unit is equipped with a hot water coil accessory. Do NOT use steam in these hot water coils. TABLE 6: STEAM COIL CAPACITY 1, MBH @ 2 PSIG 2 Steam Coil Model Unit Model CFM 1NF0453 240 1. These capacities do not include any blower motor heat. 2. Multiply these capacities by the following factors to correct for higher steam pressures. Steam pressure, psig 5 10 15 20 25 Capacity correction factor 1.05 1.12 1.19 1.25 1.30 Dry Bulb Temperature Of Air Entering Coil, ºf 10 30 50 70 6400 402 364 325 286 8000 464 419 374 330 9600 481 435 388 342 NOTE: Steam rate (lbs./hr) = 1.025 x MBH CAUTION: Do NOT operate a motor above its nominal HP rating when a unit is equipped with a hot water coil accessory. Although these coils are suitable for much higher pressures, steam above 25 psig will provide too much heat and could damage the blower motor. TABLE 7: ACCESSORY STATIC RESISTANCE (IWG) CFM Supply Air Plenum Return Air Grille Non Freeze Steam Coil Hot Water Coil 6400.03.04.14.07 7200.03.05.17.08 8000.04.06.21.10 8800.05.07.25.12 9600.06.08.29.14 TABLE 8: PLENUM PERFORMANCE CFM Throw, Feet Minimum Maximum 6400 80 145 8000 98 165 9600 115 185 6 Unitary Products Group

All dimensions are in inches. They are subject to change without notice. Certified dimensions will be provided upon request. FIGURE 2 - UNIT DIMENSIONS A B C D E F G H J K L M N P 89-1/2 85 26-1/8 29-1/2 59 2-7/16 15-7/8 12-7/16 20-3/4 16 16 20-3/4 1 1-5/8 ACCESSORIES Heating Coil - Add 6 inches to overall unit height when used. Plenum - Add 24-5/8 inches to overall unit height when used. Base - Add 23-3/8 inches to overall unit height when used. CLEARANCES 24 inches on one side for piping connection and access to blower motor. One inch on opposite side. One inch on rear. Unitary Products Group 7

ACCESSORY DIMENSIONS SHIPPED KNOCKED DOWN FOR FIELD ASSEMBLY FIGURE 3 - SUPPLY AIR PLENUM - MODEL 1SP0405 FIGURE 4 - RETURN AIR GRILLE - MODEL 1RG0405 SHIPPED KNOCKED DOWN FOR FIELD ASSEMBLY *Ventilation air can be brought into the unit through the base section providing the base section is fully insulated in the field. FIGURE 5 - BASE SECTION* - MODEL 1BS0405 8 Unitary Products Group

*Coil is field-installed between the evaporator coil and the blower section of the unit. FIGURE 6 - HOT WATER COIL* - MODEL 1HW0405 *Coil is field-installed between the evaporator coil and the blower section of the unit. FIGURE 7 - STEAM COIL* - MODEL 1NF0453 BASE UNIT SUSPENSION WEIGHTS (Lbs.) Suspension Point w/3 HP Motor 1 A 142 B 132 C 152 D 162 E 132 F 127 Total Weight 847 1. Motor location at suspension point F. FIGURE 8 - SUSPENSION KIT - MODEL 1HH0451 Unitary Products Group 9

10 Unitary Products Group

Unitary Products Group 11

Subject to change without notice. Printed in U.S.A. 293760-YTG-A-0307 Copyright by Unitary Products Group 2007. All rights reserved. Supersedes: 246654/036-21096-001-C-0206 Unitary 5005 Norman Products York OK Group Drive 73069