LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.
|
|
- Isaac Holland
- 8 years ago
- Views:
Transcription
1 LH and GH/GL Series UNIT COOLERS Technical Bulletin: LHGH_001_07101 Products that provide lasting solutions.
2 LH Series Unit Coolers Dual Discharge Low Hite Series At 9 1/ maximum height, the LH Series is perfect for low clearance walk-in applications in convenience stores, restaurants, food service or wherever more useable storage space is needed in DRY spaces -0 F and up. Standard Features n Compact design with flush ceiling mount takes up less space, allows more product to be stored on the shelf. n EC motors are standard for 11/1 and 0/1. n Two-way air discharge provides smooth air movement, keeps product fresh longer with less drying and weight loss. n High efficiency coil with staggered copper tubes for optimum heat transfer and proper system balance. n These coils can be used for fluid and CO circuiting. n All controls are factory wired to a terminal strip for easy installation. Optional Features and Accessories n PSC fan motors. n TEV (Thermostatic Expansion Valve) shipped loose or factory mounted. n LLSV (Liquid Line Solenoid Valve) loose. n SLHX (Suction Liquid Heat Exchanger) loose. n Defrost Time Clock (loose). Defrost Methods n Air or Off-Cycle for rooms above + F. n Electric for rooms -0 F and above. Specify When Ordering All Models n Complete model number. n Refrigerant R, R0A, or R07. n Room temperature. n Optional features. n Saturated suction temperature. n Optional accessories. Common Replacement Parts AFTERMARKET PART PART # EC MOTOR 11V (standard) 1091 EC MOTOR 0V (standard) 109 PSC MOTOR 11V (optional) 1080 PSC MOTOR 0V (optional) 1080 GL FAN GH/LH FAN FAN GUARD AIR FILTER Model Key Dimensional Data LH A B B A Unit Type LH = Low Hite Number of Fans Fin Spacing FPI FPI Type of Defrost A = Air Defrost B = Brine E = Electric with Electric Pan R = Heat Reclaim Heater Voltage A = 0/1/0 Motor Voltage A = 08-0/1/0 B = 11/1/0 Motor Type B = PSC Motors (Optional) E = EC Motors (Standard) BTU/h in Hundreds (00) 1
3 LH Series Unit Coolers Defrost Standard Velocity Specifications Fins per Inch LH1A-7 LHA-9 LHA-10 LHA-187 Fins per Inch LH1A- LHA-7 LHA-109 LHA-1 CAP. 10 TD,700 9,00 1,000 18,700,00 7,00 10,900 1,00 CAP. 10 TD SST SST Fins per Inch LH1E- LHE-8 LHE-19 LHE-171,00,700 8,00 9,00 1,9001,000 17,10018,700 Fins per Inch LH1E- LHE-7 LHE-100 LHE-1,00,00 7,00 7,00 10,900 10,900 1,001,00 AIR FLOW (CFM) 0 1,00 1,90,00 8 1,,08,70 AIR FLOW (CFM) 0 1,00 1,90,00 8 1,,08,70 AIR DEFROST - MEDIUM TEMPERATURE CHARGE EC MOTORS STANDARD PSC MOTORS OPTIONAL LBS OF 11/1/0 0/1/0 11/1/0 0/1/0 REFRIG AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS *ELECTRIC DEFROST - LOW TEMPERATURE CHARGE LBS OF REFRIG L W H EC MOTORS STANDARD PSC MOTORS OPTIONAL HEATERS 11/1/0 0/1/0 11/1/0 0/1/0 0/1 AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS *Note: Refer to Air Defrost chart above for Electric Defrost dimensions. Wiring Diagrams Air Defrost Wiring Electric Defrost Wiring 08-0/1/0-0 FAN MOTORS FACTORY WIRING FIELD WIRING
4 GH/GL Series Unit Coolers Standard Features Ideal for medium temperature low air circulation applications in spaces above +0 F. Standard Features n Ten inch diameter aluminum fans, direct driven at 10 RPM, blow air uniformly through twin coils creating a low velocity umbrella air distribution. n EC motors are standard for 11/1 and 0/1. n Low and high silhouette models may be installed level and tight to ceiling. Hanger rods and TEV are internal resulting in a clean appearance. n High efficiency coils, four rows deep with /8 diameter staggered copper tubes are mechanically expanded into corrugated aluminum fins spaced by tube collars. Direct expansion circuiting for halocarbon refrigerants is standard. n Serviceable, textured aluminum housing features hinged orifice drain pan, pitched to drain condensate at end of unit. n Low sound levels range from decibels generated by one fan units to 0 decibels for six fan units, as measured on the A scale, six feet horizontally from the center of the unit. n These coils can be used for fluid and CO circuiting. n Capacity ratings are sensible heat removal with externally equalized TEV fed medium frosted coil. Fan motor heat is not included in rating. Add 8 BTUH per fan to room load. Derate 1% for 0 HERTZ (BTUH x.088) or increase TD to compensate for lower fan RPM. Optional Features n Insulated drain pan construction. n Copper fins or vinyl coated aluminum fins. n Epoxy coating of entire tube and fin surface. n Coils circuited for water or glycol fluids. n PSC fan motors. Model Key Optional Accessories n TEV (Thermostatic Expansion Valve) shipped loose or factory mounted. n LLSV (Liquid Line Solenoid Valve) loose. n SLHX (Suction Liquid Heat Exchanger) loose. n Defrost Time Clock shipped loose. n Washable Air Inlet Filters (Air Defrost only). Defrost Methods n AIR or OFF-CYCLE for rooms above + F. n ELECTRIC for rooms +0 F and above (coil only not available with vinyl coated fins or epoxy coated coil) n GAS (KG- pipe) or (HG- pipe) for rooms above + F. n GAS (KGE or HGE) with electric drain pan booster heat for rooms +0 to + F. Specify When Ordering All Models n Complete model number. n Refrigerant R, R0A, or R07. n Room temperature. n Optional features. n Saturated suction temperature. n Optional accessories. Common Replacement Parts AFTERMARKET PART PART # EC MOTOR 11V (standard) 1091 EC MOTOR 0V (standard) 109 PSC MOTOR 11V (optional) 1080 PSC MOTOR 0V (optional) 1080 GL FAN GH/LH FAN FAN GUARD AIR FILTER GL A B A K Unit Type GH & GL = Gentle Air Number of Fans Fin Spacing FPI FPI Type of Defrost A = Air Defrost B = Brine D = Electric with No Pan Heat F = Pipe Hot Gas with No Pan Heat H = Pipe Hot Gas with Electric Drain Pan M = Pipe Kool Gas with No Pan Heat P = Pipe Kool Gas with Electric Drain Pan R = Heat Reclaim Heater Voltage A=08-0/1/0 B=11/1/0 K=08-0//0 Motor Voltage A=08-0/1/0 B=11/1/0 Motor Type B=PSC Motors (Optional) E = EC Motors (Standard) BTU/h in Hundreds (00)
5 GH/GL Series Unit Coolers Air Defrost Low Velocity Specifications Fins per Inch GH1A-0 GHA-10 GHA-1 GHA-70 GHA-0 GHA-10 Fins per Inch GH1A-0 GHA-100 GHA-10 GHA-00 GHA-0 GHA-00 Fins per Inch GL1A- GLA-90 GLA-1 GLA-180 GLA- GLA-8 Fins per Inch GL1A- GLA-70 GLA-10 GLA-10 GLA-17 GLA-10 GENTLE AIR - 18" HIGH SILHOUETTE - MEDIUM TEMPERATURE PSC MOTORS OPTIONAL CAPACITY AIR CHARGE EC MOTORS STANDARD (BTUH) FLOW LBS OF 11/1/0 0/1/0 11/1/0 10 TD (CFM) R0A AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS L W H,000 1,000 19,800 7,000,000 1,000,000 10,000 1,000 0,000,000 0, ,800,700,00,00, ,880,80,70,700, GENTLE AIR - 1" LOW SILHOUETTE - MEDIUM TEMPERATURE CAPACITY AIR EC MOTORS STANDARD PSC MOTORS OPTIONAL CHARGE (BTUH) FLOW LBS OF 11/1/0 0/1/0 11/1/0 10 TD (CFM) R0A AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS L W H,00 9,000 1,00 18,000,00,800,00 7,000 10,00 1,000 17,00 1, ,00 1,800,00,000,00 0 1,0 1,890,0,10,
6 GH/GL Series Unit Coolers Electric Defrost Low Velocity Specifications Fins per Inch GH1D-0 GHD-10 GHD-1 GHD-70 GHD-0 GHD-10 Fins per Inch GH1D-0 GHD-100 GHD-10 GHD-00 GHD-0 GHD-00 Fins per Inch GL1D- GLD-90 GLD-1 GLD-180 GLD- GLD-8 Fins per Inch GL1D- GLD-70 GLD-10 GLD-10 GLD-17 GLD-10 GENTLE AIR - 18" HIGH SILHOUETTE - MEDIUM TEMPERATURE CAPACITY AIR CHARGE EC MOTORS STANDARD PSC MOTORS OPTIONAL HEATERS (BTUH) FLOW LBS OF 11/1/0 0/1/0 11/1/0 0/1/0 10 TD (CFM) R0A AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS L W H,000 1,000 19,800 7,000,000 1,000,000 10,000 1,000 0,000,000 0, ,800,700,00,00, ,880,80,70,700, GENTLE AIR - 1" LOW SILHOUETTE - MEDIUM TEMPERATURE CAPACITY AIR CHARGE EC MOTORS STANDARD PSC MOTORS OPTIONAL HEATERS (BTUH) FLOW LBS OF 11/1/0 0/1/0 11/1/0 0/1/0 10 TD (CFM) R0A AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS AMPS WATTS L W H,00 9,000 1,00 18,000,00,800,00 7,000 10,00 1,000 17,00 1, ,00 1,800,00,000,00 0 1,0 1,890,0,10, Phase Only Phase Only
7 GH/GL Series Unit Coolers Dimensional Data UNIT DIMENSIONS SIZE A B C D E F GH-1 FAN GH- FAN GH- FAN GH- FAN GH- FAN GH- FAN GL-1 FAN GL- FAN GL- FAN GL- FAN GL- FAN GL- FAN Note: Dimensions in inches. Wiring Diagrams Electric Defrost Wiring 08-0/1/0-0 Electric Defrost Wiring 08-0//0-0 Air Defrost Wiring FAN MOTORS FACTORY WIRING FIELD WIRING
8 Use your QR reader to reference current document version on Krack, a Hussmann Corporation brand 890 Remington Boulevard Bolingbrook, Illinois 00 Ph: Printed in U.S.A. 01 Krack. a Hussmann Corporation brand LHGH_001_07101
Low Profile Unit Cooler
Super-Flo Now available with EC Motors High Efficiency / High Reliability Low Profile Unit Cooler Publication No. 411.4 November, 2008 S A N I T A T I O N F O U N D A T I O N A L N A T I O N Air Defrost
More informationFan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain Ship. Wt. Lbs.
COMPACT UNIT FOR CEILING OR WALL MOUNT Fan Dia. Motor Amps Connections Approx. 115 V 10 O TD 15 O TD H W D CFM (Quantity) 115 V 230 V Inlet Suction Drain. MJ-40 400 600 7 13 5/8 8 125 5 1/4" 0.65 0.35
More informationCARRIER REFRIGERATION EQUIPMENT AND PARTS
EVAPORATOR COILS CONDENSING UNITS 1/2 Through 80 HP COMPLETE REFRIGERATION PACKAGES AIR DEFROST ELECTRIC DEFROST HOT GAS DEFROST Ceiling Temp Low Height Unit Coolers SW Series Literature No. C 230.0 January,
More informationSECTION 15750 PACKAGED ROOFTOP AIR CONDITIONING UNITS
SECTION 15750 PART 1 - GENERAL 1.01 DESCRIPTION A. Section includes requirements for roof mounted, self-contained units, with electric cooling, and electric or reverse refrigeration cycle (heat pump) heating
More informationKRAMER ELECTRIC DEFROST EVAPORATORS LPE - LVE - MSE - CSE - HSE - CED - KED INSTALLATION, START-UP AND MAINTENANCE INSTRUCTIONS
BULLETIN EDEI-812 SEPTEMBER, 1999 NEW KRAMER ELECTRIC DEFROST EVAPORATORS LPE - LVE - MSE - CSE - HSE - CED - KED INSTALLATION, START-UP AND MAINTENANCE INSTRUCTIONS 14230 Lochridge Blvd - Covington, Georgia
More informationPRE-ASSEMBLED REMOTE REFRIGERATION SYSTEMS
NOR-LAKE, INCORPORATED 727 Second Street P.O. Box 248 Hudson, Wisconsin 54016 800-955-5253 715-386-2323 866-961-5253 Parts 800-388-5253 Service 715-386-4291 FAX www.norlake.com Split-Pak Pre-Assembled
More informationHow To Understand Evaporator
SECTION 5 COMMERCIAL REFRIGERATION UNIT 21 EVAPORATORS AND THE REFRIGERATION SYSTEM UNIT OBJECTIVES After studying this unit, the reader should be able to Define high-, medium-, and low-temperature refrigeration.
More informationLSA LSE, LSR & LST LPA LPE, LPG & LPH LAA LAE, LAG & LAH COMMERCIAL WALK-IN COOLERS AND FREEZERS
FOR COOLERS ABOVE +34ºF Low silhouette, draw through, high velocity units Capacity from 4,500 to 39,000 BTU/HR./10ºF TD LSA LSE, LSR & LST FOR COOLERS AND FREEZERS FROM -20ºF TO +34ºF Low silhouette, draw
More informationSlim Line KUC Unit Coolers 60Hz
Slim Line KUC Unit Coolers 60Hz PRODUCT DATA & INSTALLATION Bulletin K30KUCPDI10 1043681 We are on the Internet www.keepriterefrigeration.com High, Medium and Low Temperature Applications 40 F (40 C) and
More informationM SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A
Bulletin 20-20.2 / July 2012 M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A ➀ ➁ ➂ Model Number Key M 2430 C L 1 - A - ➀ Unit Type M=Modular Nominal Capacity 2430=24000 to 30000
More informationhore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &
hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS
More informationCold Room & Refrigeration System (Casserole Assembly) No of units: 1
Technical Specifications Cold Room & Refrigeration System (Casserole Assembly) No of units: 1 For chiller storage of all sorts of items Chiller storage temperature: 2-5 C Provides excellent thermal efficiency
More informationMAC-120HE-01 Air-Cooled Chiller
MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01
More informationInstallation Manual CLIFC Fan & Coil Variable Speed
Installation Manual CLIFC Fan & Coil Variable Speed General Description GENERAL DESCRIPTION FANS EQUIPMENT Totally Factory assembled within the unit all piping, wiring, and required controls for operation
More informationAluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03
Aluminum Cased Cooling Coils 2-5 Ton 4CXC PUB. NO. 22-1839-03 Aluminum Cooling Coil Nomenclature 4 C X C B 0 3 6 C C 3 C U A A Refrigerant Type 4 - R410A Product Family T-Premium (Heat Pump or Convertible
More informationARMSTRONG AIR HEAT PUMPS www.armstrongair.com
INDEX ELECTRIC FURNACE MODULAR AIR SYSTEM EFC/EFV... 5-10 electric Heat Kits... 5-11 evaporator coils EC1P / EM1P UPFLOW / COUNTERFLOW APPLICATIONS and upflow / horizontal applications (CASED)... 5-6 5-7
More informationSECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM
SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2
More informationAIR-COOLED CONDENSERS Technical Guide
BN-ACCTB0306 March, 2006 AIR-COOLED CONDENSERS Technical Guide Monarch and Ambassador Series TABLE OF CONTENTS Overview... 2, 3 Features & Options... 3, 4 Three Solutions...5 Nomenclature...6 Condenser
More informationSlim Contour Unit Cooler
Slim Contour Unit Cooler with Modular Cassette Design ULA Models Questions & Answers Table of Contents What is the Slim Contour unit cooler?... 2 Why was this product developed?... 2 What are the key benefits
More informationDefining Quality. Building Comfort. Heating and Cooling Coils
Defining Quality. Building Comfort. Heating and Cooling Coils Heating and Cooling Coils Heating and Cooling Coils For over 20 years, AAON has supplied the coil needs of industrial and commercial HVAC customers.
More information1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None
1-Way Chilled Water Cassettes KCO 60, 90 & 120 Technical Brochure TM KCO-W.1GB Date : November 2005 Supersedes : None General Features Control valve (optional) Air vent In-tube electric heating elements
More informationSECTION 11 78 13 MORTUARY REFRIGERATORS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 11 78 13 MORTUARY REFRIGERATORS SPEC WRITER NOTE: Delete between //---// if not applicable to project. Also delete any other item or paragraph not applicable in
More informationSECTION 23 81 43 HEAT PUMPS
SECTION 23 81 43 HEAT PUMPS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop heat pumps. 1.2 REFERENCES A. American Society of Heating, Refrigerating and Air-Conditioning Engineers:
More informationVertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water
2 to 15 tons Water-Cooled and Chilled Water Unique Solutions for Challenging HVAC Projects Your Choice for Limited Space Applications Water-Cooled Chilled Water The VertiCool Space Saver allows installation
More informationCB29M Bulletin #490071 February 1996
ENGINEERING DT MTCHED REMOTE SYSTEMS 50hz S LOWER UNITS 50hz ELITE 10 MULTI POSITION LOWER UNITS 20 100 to 49 00 tuh (5.9 to 14.4 kw) Cooling Capacity 19 700 to 49 100 tuh (5.8 to 14.4 kw) Heat Pump Heating
More informationCharacteristics of Evaporators
Characteristics of Evaporators Roger D. Holder, CM, MSME 10-28-2003 Heat or Energy In this paper, we will discuss the characteristics of an evaporator coil. The variance of the operational condenses of
More informationContents and Nomenclature
DX Coils Contents and Nomenclature Nomenclature... 1 Evaporator Coil Types EN... 2 EF... 2 ER... 2 EJ... 3 EK... 3 Evaporator Construction Connections... 4 Tubing... 4 Headers... 5 Tube Supports... 5 Coil
More informationTable Z. Troubleshooting Chart for Air Conditioners. Cause
Troubleshooting Chart for Air Conditioners Type of Unit Complaint Cause With open-type compressor Electric motor will not start Power failure Check circuit for power source Compressor stuck Locate cause
More informationDEFROSTING. Service Engineers Section Technical Bulletin No 3
Service Engineers Section Technical Bulletin No 3 DEFROSTING 1. INTRODUCTION This bulletin is presented to cover the methods used and problems experienced with defrosting of coils for chill and frozen
More informationXV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE
UPF/HORIZONTAL 2-, VARIABLE SPEED GAS-FIRED FURNACE XV80 MODELS TUD2B060A9V3VB, TUD2B080A9V3VB TUD2C080A9V4VB, TUD2C080B9V4VB TUD2B00A9V3VB, TUD2C00A9V5VB TUD2C00B9V5VB, TUD2DA9V5VB TUD2DB9V5VB, TUD2DA9V5VB
More informationtechnical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air
technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t
More informationNew Deluxe Wall Mounted Heat Pump Series EXTERIOS
New Deluxe Wall Mounted Heat Pump Series EXTERIOS May 2013 New Deluxe Wall Mounted Heat Pump Series Panasonic Adding New Air Conditioner Lineup Setting Another Mile Stone in the US Ductless Split History
More informationAIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency
FORM NO. H11-52 REV. 3 Supersedes Form H11-52 Rev. 2 AIR HANDLERS AIR HANDLERS RHLA- Efficiency featuring R-22 Refrigerant RHLL- Efficiency featuring Earth-Friendly R-10A Refrigerant earth friendly refrigerant
More informationDESIGN STANDARDS SECTION 23 60 00
PART 1 - GENERAL 1.01 Work included: A. Piping, tubing and fittings. B. Piping specialties. C. Special duty valves. D. Refrigerants. E. Chillers. F. Refrigerant monitors. 1.02 General requirements: A.
More informationUR...3 URX CF...7 URHE CF...11. Heat recovery unit. Heat recovery unit with refrigerant circuit(442-1947 cfm)
UR...3 Heat recovery unit URX CF...7 Heat recovery unit with refrigerant circuit(442-1947 cfm) URHE CF...11 High efficiency heat recovery unit with refrigeration circuit(588-1942 cfm) UR Heat recovery
More informationDUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS
DUCTLESS MINI-SPLITS SINGLE & MULTI-ZONE HORIZONTAL AIR CONDITIONERS PORTABLE UNITS FREE MATCH COMPONENTS AN EXCELLENT CHOICE IN COOLING, COMFORT AND CONVENIENCE Why choose a Mini-Split system? Installing
More informationCEILING CASSETTE FAN COIL UNIT
CEILING CASSETTE FAN COIL UNIT Operation and Installation Manual MHCFC4W-04, 08, 12, 16 Four way ceiling cassette fan coil unit Please read this manual before using the fan coil unit. Installation and
More informationGlossary of Heating, Ventilation and Air Conditioning Terms
Glossary of Heating, Ventilation and Air Conditioning Terms Air Change: Unlike re-circulated air, this is the total air required to completely replace the air in a room or building. Air Conditioner: Equipment
More informationmarine/bespoke split applications
split applications marine/bespoke evaporators, condensers and split air conditioning systems suitable for a multitude of applications such as coastal, extreme high and low ambients, harsh dusty environments
More informationAuxiliary HVAC RAM ProMaster. Standard Tie-in Extreme Climate System
Auxiliary HVAC RAM ProMaster Standard Tie-in Extreme Climate System Auxiliary HVAC High performance aftermarket heating and cooling systems engineered for vehicle specific platforms that minimize install
More informationSINGLE PACKAGE VERTICAL AIR CONDITIONERS
SINGLE PACKAGE VERTICAL AIR CONDITIONERS AIR CONDITIONERS l HEAT PUMPS l ELECTRIC HEAT QUIETER BY DESIGN SIMPLE TO INSTALL CONCEALED INSTALLATION www.friedrich.com VERT-I-PAK ideal for extended stay properties,
More informationHeating, Ventilation, Air Conditioning and Refrigeration (HVACR)
Heating, Ventilation, Air Conditioning and Refrigeration (HVACR) I. Demonstrate safety skills in typical HVACR work situations to NATE Core Installer Knowledge Areas for Technician Excellence for Safety
More informationControlled Environment Products & Commercial Refrigeration Price List
Effective 1/01/2015 Controlled Environment Products & Commercial Refrigeration Price List Controlled Environment Equipment - Pages 2-8 Cabinet and wine wall installations (CTI) Ducted units (HS) Controlled
More informationSECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS
SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES After studying this unit, the reader should be able to explain the purpose of the condenser in a refrigeration system. describe differences
More informationChilled Water HVAC Systems
Chilled Water HVAC Systems By Ron Prager, Brinco Mechanical Services, Inc. Types of water based systems: There are three types of HVAC systems that utilize water as a heat transfer medium. The first system,
More informationNSN 4120-01-21 4-3692
*TM 9-4120-388-14 TECHNICAL MANUAL Operator s, Unit, Direct Support, And General Support Maintenance Manual AIR CONDITIONER, VERTICAL, COMPACT, 18,000 BTU/HR 208 VOLT, 3 PHASE, 50/60 HERTZ NSN 4120-01-21
More informationSWIMMING POOL HEAT PUMP
SWIMMING POOL HEAT PUMP Installation & User Manual Model HP40B HP50B HP65B Hayward Pool Products Canada, Inc. T: 1-888-238-7665 www.haywardpool.ca CONTENT I. Application 4 II. Features 4 III. Technical
More informationECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
More informationCOIL INPUT SCREENS. ITEM NUMBER: Always use a 1 through? In this field you might also use a dash and place quantity of coils here.
COIL INPUT SCREENS Example of a Water Coil Input Screen: (*please see the appendix for an example of an Evaporator, Steam or Condenser Coil input screen) PHYSICAL DATA ITEM NUMBER: Always use a 1 through?
More informationDESCRIPTION FEATURES HORIZONTAL DUCT HD. ISO 9001 Certified Quality Management System
TECHNICAL GUIDE ADD - ON COILS FOR USE WITH SPLIT-SYSTEM COOLING & HEAT PUMPS MODELS: MC, PC, FC, HD, UC 600-2000 CFM 1.5-5 TON COILS UPFLOW/DOWNFLOW FULL CASED FC UPFLOW PARTIAL CASED PC UPFLOW UNCASED
More informationChilled Water Fan Coil Unit. Model:HFCA Size 03~14
Chilled Water Fan Coil Unit Model:HFCA Size 03~4 The Best Choice for Comfort =The Best Results Quiet Comfort Slope coil avoid air flow perpendicular impact Low noise permanent split capacitor motor Metal
More informationTWE+TTA TWE+TWA 6.25-20 T.R.
TWE+TTA TWE+TWA 6.25-20 T.R. Main features : TWE indoor unit : Convertible cabinet, vertical or horizontal. Adjustable speed pulley-belt drive centrifugal fan motor. Aluminium fin coil with copper-tubes.
More informationRefrigeration System Installation & Operation Manual
Refrigeration System Installation & Operation Manual Manitowoc Foodservice Walk-In Division 2915 Tennessee Avenue North P.O. Box 550 Parsons, TN 38363 Phone: 800-225-9916 www.manitowocfsusa.com 550001058-3
More informationTECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL 387030095 AW64AL 0.8180.463.0 07/05
TECHNICAL DATA & SERVICE MANUAL INDOOR UNIT: AW52AL AW64AL SPLIT SYSTEM AIR CONDITIONER Model No. Product Code No. AW52AL 387030095 AW64AL 387030096 0.8180.463.0 07/05 IMPORTANT! Please read before installation
More informationINDOOR COILS. RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-213 REV. 4 Supersedes Form No. C11-213 Rev. 3 INDOOR COILS RCFN- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More informationGCS16-024-030-036-048-060
Packaged Unit & Gas Heat 2-5 Ton Capacity 50,000-120,000 Btuh Input Heating Capacity GCS16-024-030-036-048-060 FEATURES Designed for outdoor rooftop or ground level installations Down-flow or horizontal
More informationXV 95. Upflow/ Horizontal Left, Downflow/ Horizontal Right Variable Speed Two Stage Condensing Gas-Fired Furnace PUB. NO.
Upflow/ Horizontal Left, Downflow/ Horizontal Right Speed Two Stage Condensing Gas-Fired Furnace XV 95 TUH2B060A9V3VB TUH2B080A9V3VB TUH2B080A9V4VB TUH2C100A9V4VB TUH2C100A9V5VB TUH2D120A9V5VB Direct Vent
More informationCA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:
CA SERIES T he CA Aquarius Series Console Units offer the answer to providing heating and cooling to areas where space and access is limited. Office buildings, hotel/motels, schools and assisted living
More informationcatalog Single Package Vertical Air Conditioners and Heat Pumps
catalog Single Package Vertical Air Conditioners and Heat Pumps Catalog: SK145.00-EG1 (1008) TABLE OF CONTENTS Single Package Vertical Units Introduction...............................................................................
More informationTable V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.
Table V Troubleshooting Checklist for Refrigeration Systems TROUBLE POSSIBLE CAUSE CORRECTIVE MEASURE High condensing pressure. Low condensing pressure. Air or non-condensable gas in system. Inlet water
More informationCooling/Heat Pump Convertible Air Handlers
Cooling/Heat Pump Convertible Air Handlers 2/4TEC3F18-60A1000A 1½ 5 Ton PUB. NO. 22-1774-01-0905 (EN) Features and Benefits 13.0 SEER Ships horizontal converts to vertical by standing unit on end. Six-way
More informationRefrigeration Basics 101. By: Eric Nelson
Refrigeration Basics 101 By: Eric Nelson Basics Refrigeration is the removal of heat from a material or space, so that it s temperature is lower than that of it s surroundings. When refrigerant absorbs
More informationINDOOR COILS. RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 7 Supersedes Form No. C11-211 Rev. 6 INDOOR COILS RCFL- featuring Industry Standard R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES 600-1,900 CFM
More information26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS.
T H R U - T H E - W A L L A I R C O N D I T I O N E R S 26 AND 27 SLEEVES. IDEAL for NEW CONSTRUCTION, RETROFITS and REMODELS. W A L L M A S T E R T H R U - T H E - W A L L A I R C O N D I T I O N E R
More informationTHE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM
THE CASE FOR A REFRIGERATION PREVENTATIVE MAINTENACE PROGRAM Prepared and Presented By: Don Langston President & CEO, Aire Rite Air Conditioning & Refrigeration Inc Setting the Foundation The Refrigeration
More informationNew Trends in the Field of Automobile Air Conditioning
New Trends in the Field of Automobile Air Conditioning E. Janotkova and M. Pavelek Department of Thermomechanics and Environmental Engineering Brno University of Technology, 61669 Brno, Czech Republic
More informationINDOOR COILS. RCFM- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-212 REV. 1 Supersedes Form No. C11-212 INDOOR COILS RCFM- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES AIRFLOW CAPACITIES
More informationGas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF24-100-400 (10/2011) LF24 Standard
LF Standard Features Horizontal unit heaters are compact in design and easy to install. Steady State Efficiencies of up to 80.%. Ideal for economical commercial heating systems. Shipped completely assembled
More informationSolenoid Valves and Their Importance in Refrigeration Systems. October 2007
Solenoid Valves and Their Importance in Refrigeration Systems October 2007 Overview Introduction Solenoid valves play an important role within refrigeration and air conditioning systems, controlling the
More informationDERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description
Description Compact air/water heat pump for outside installation. With suction gas cooled rotary compressor. With extensive aluminium/cu lamellar tube evaporator and PVC Titanium condenser. Axial fan Refrigerant
More informationTroubleshooting an Air Conditioning system. R D Holder Eng. Roger D Holder MSME
Troubleshooting an Air Conditioning system R D Holder Eng. Roger D Holder MSME Troubleshooting of an air conditioning system is a step by step procedure. I have found that a 4 step procedure is the best
More informationElegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner
Elegant ECM Ceiling Air Conditioner ELEGANT ECM air conditioners allow to heat and cool very economically small and medium areas, like shops, show rooms, workshops, supermarkets. The range is made up of
More informationModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60
ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA12-20-24-30-36-42-48-60 General Description The Marvair ModPac II air conditioner is a vertical, wall mounted, cost effective air conditioner
More informationAccumulators and Receivers
aerospace climate control electromechanical filtration fluid & gas handling hydraulics pneumatics process control sealing & shielding Accumulators and Receivers Catalog C-1, October 2007 Page 2 / Catalog
More informationSWIMMING POOL AIR-HANDLING UNITS KU-DB Series
SWIMMING POOL AIR-HANDLING UNITS KU-DB Series ME20 proklima 2 SWIMMING POOL AIR-HANDLING UNITS - KU-DB Series proklima 3 TABLE OF CONTENTS 1 Introduction page 3 2 Features page 4 SWIMMING POOL AREA t =
More informationHEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:
HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER: It is normal for a heat pump to have a build up of white frost on the outside coil during cold damp weather. The
More informationAppendix - Controllers 179
Version: 200703 Appendix - Controllers 179 -3- -4- -5- -6- -7- -8- 2. Specifications 2.1 Specifications for inverter units item Model AB182ACERA Function cooling heating Capacity kw 5.01.8--5.8 5.22.0---6.2
More informationTroubleshooting HVAC/R systems using refrigerant superheat and subcooling
Troubleshooting HVAC/R systems using refrigerant superheat and subcooling Application Note Troubleshooting and servicing refrigeration and air conditioning systems can be a challenging process for both
More informationREFRIGERATED TYPE COMPRESSED AIR DRYERS INSTRUCTION MANUAL. For Sales & Service please contact:
7610.478.16 8/99 INSTRUCTION MANUAL Models 8005, 8010, 8015 For Sales & Service please contact: CENTRAIR Air Systems & Supplies Phone: 705-722-5747 Fax: 705-722-5458 Email: sales@centrair.ca Website: www.centrair.ca
More informationINDOOR COILS. RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant CASED/UNCASED COILS FOR GAS AND OIL FURNACES
FORM NO. C11-211 REV. 3 Supersedes Form No. C11-211 Rev. 2 INDOOR COILS RCFA- featuring R-22 Refrigerant RCFL- featuring Earth-Friendly R-410A Refrigerant earth friendly refrigerant CASED/UNCASED COILS
More informationENGINEERING GUIDE. Water-Cooled Self-Contained Units C-Series, Vertical
ENGINEERING GUIDE Water-Cooled Self-Contained Units C-Series, Vertical TABLE OF CONTENTS Introduction...2 Product Overview...3 Nomenclature...4 General Data...5 Cooling Performance Data....6 Evaporator
More informationSteam Coil Installation, Operation and Maintenance
Steam Coil Installation, Operation and Maintenance Guidelines for the installation, operation and maintenance of the Heatcraft brand of steam heating coils manufactured by Luvata in Grenada, MS have been
More informationCAB LCAB HACAB RMP/AMP CC CY/YY RVP CUSTOM CU
GENERAL PURPOSE (ORDINARY) LOCATION Custom Controls provides the petro-chemical and offshore industries with HVAC equipment of the highest quality and reliability on the market at an economical price.
More informationCeiling Mount Air Handler Manual
www.surna.com 303.993.5271 Ceiling Mount Air Handler Manual Models: CMAH12, CMAH18, CMAH24, CMAH30, CMAH36, CMAH48, CMAH60 Revised: September 2014 Table of Contents Warranty Information 4 Limited Warranty
More informationCPX/HT Series. REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM. High-performance products. Designed for you!
CPX/HT Series REFRIGERATED AND HIGH TEMPERATURE DRYER 12 to 2400 CFM High-performance products. Designed for you! COMPRESSED AIR WATER CONTAMINATION Atmospheric air contains water in vapor form in different
More informationCRAC Precision climate control units for data centres
CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have
More informationSECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION
SECTION 23 05 93 TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION The purpose of this guide specification is to assist the specifier in correctly specifying Mechanical System Testing
More informationOil and Coolant Circulating Heating System. Model - OCSM
Oil and Coolant Circulating Heating System Model - OCSM Installation & Operation Manual 216280-000 REV 2 Identifying Your System The HOTSTART heating system is designed to heat fluids for use in marine
More informationCADB and CADT-D / DI / DC Series
HEAT RECOVERY UNITS CADB and CADT-D / DI / DC Series NEW The CADB, CADT heat recovery range consists of: - Self-supporting casing with extruded aluminium profile structure and beige plastic coated galvanised
More informationLight Duty Commercial Electric Water Heater
Features Heavy Duty Construction Hydrastone cement lining provides longer tank life Copper-silicon tappings cannot rust or corrode High impact composite jacket eliminates damage during installation and
More informationWhy is my air conditioner dripping on my customers?
De-Mystifying HVAC Why is my air conditioner dripping on my customers? By Ron Prager One of the most frequent emergency service requests is a call for an air conditioner leaking water into the store. These
More informationRefrigeration Installation 101
Refrigeration Installation 101 Hundreds of Installations Refrigerated Cases 2 Compressor Racks 3 Condensing Units 4 Walk-in Boxes 5 Some were done very well 6 Some had some issues... 7 8 Some seemingly
More informationHow Ground/Water Source Heat Pumps Work
How Ground/Water Source s Work Steve Kavanaugh, Professor Emeritus of Mechanical Engineering, University of Alabama Ground Source s (a.k.a. Geothermal s) are becoming more common as the costs of energy
More informationyork air-conditioning products Residential & VRF News 2015
york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter
More informationSplit System Heat Pump Product Data
Split System Heat Pump Product Silver 14 4A6H4 1 1 /2-5 Tons PUB. NO. 12-1175-07 Contents Features and Benefits 2 Model Nomenclature 3 General 4 Product Specifications 4 A-weighted Sound Power Level [db(a)]
More informationTroubleshooting Your Refrigerator
Troubleshooting Your Refrigerator With conscientious care, a refrigerator will perform for years with little or no repairs. Refrigerators are categorized according to the way frost is removed from them.
More informationCONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM 11 5. EXPLOSION VIEW 12 6.
TCL WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS SERVICE MANUAL No.TE051220 Models TAC-09CHSA/GI TAC-12CHSA/GI CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM
More informationCased/Uncased Coils For Gas And Oil Furnaces
Indoor Coils Cased/Uncased Coils For Gas And Oil Furnaces RCFL- Series featuring Industry Standard R-410A Refrigerant Airflow Capacity 600-1,900 CFM [283-897 L/s] Rheem Indoor Coils are designed for use
More informationEngineering Recommendation on: Accumulators Revised 6-17-99 Issued January 10, 1979 Page 1 of 7
Issued January 10, 1979 Page 1 of 7 Accumulators have long been recognized by the industry as an effective means of maintaining good system balance by storing excess refrigerant as the condenser or evaporator
More informationLocal Dealer: www.cebrands.com
Local Dealer: C.E. LLC - Miami, FL USA www.cebrands.com Res2012-Rev2 QUALITY YOU CAN FEEL Residential Product Line >TCA7,9 Tempstar SmartComfort TXT + Air Conditioner Featuring The Observer Communication