Manual motor starter MS116

Similar documents
Manual motor starter MS116

Electronic overload relay EF19 and EF45

Electronic overload relay EF65, EF96 and EF146

Three-phase monitoring relay CM-PFE

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Catalog. Modular DIN rail components Installation contactors

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Analog signal converters CC-E I/I Current / current isolators

Type: DILM32 10(24V50HZ) Article No.:

Manual Motor Starter MS 116 up to 16 A Technical Data

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Type: DILM50(230V50HZ,240V60HZ) Article No.:

Type: DILM9 10(24VDC) Article No.:

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Technical catalogue. Modular DIN rail components Installation contactors

Thermistor motor protection relays CM-MSS.22 and CM-MSS.23

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

Technicaldata General

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

Molded Case Circuit Breaker Specifications Bulletin Number 140U-D

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

System pro M compact Miniature Circuit Breaker S 200/S 200 M

Micro Contactors. Micro Contactor Relays. Micro Contactors With Solder Pins. Coil voltages. Micro Reversing Contactor. Technical Data.

ZS4-S-T Screw Clamp Terminal Blocks Disconnect with blade - with test socket

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

ZS25 Screw Clamp Terminal Blocks Feed-through

Bimetallic Overload Relay Specifications

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.43

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

R.C.C.B. s two-pole LEXIC

RM4TG20 three-phase network control relay RM4-T - range V

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Pluggable interface relays CR-P Pcb relays

Thermistor motor protection

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

PSR The compact range Description

Series 8146/5-V37 and Series 8150/5-V37

Relés e Contatores de Estado Sólido SIRIUS

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

5SV Residual Current Protective Devices

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

SIRCOVER. Manual changeover switches from 125 to 3200 A. Changeover switches. Function. Advantages. The solution for.

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Soft Starter. Product Description. Ordering Code. Type Selection. Selection Guide RSG D E 0 VD00

Safety automation solutions

Bulletin 150 SMC Flex Smart Motor Controller Specifications

Redundancy Module QUINT-DIODE/40

MNS is Switchgear System Technical Overview

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Plug and Socket Devices CES 63 A Series 8579

Application Switchgear for industrial and commercial applications. U e V AC 230/ (per pole)

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ZS10 Screw Clamp Terminal Block

38 Series - Relay interface modules A

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

PHOENIX CONTACT Features

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

38 Series - Relay interface modules A

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Catalog Edition DIN-Rail components for rolling stock applications

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

Safety technique. Emergency stop module BO 5988 safemaster

48 SERIES Relay interface modules 10 A

Quick Connect. quick - simple - efficient.

The complete range of consumer switchboards and switchgear

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

CQM1-SF200/CS1W-SF200

Low Voltage Fuses For Motor Protection

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

MasterINTERFACE 39 Series - Relay interface modules

D-Line Contactors, Overload Relays and Accessories

MasterINTERFACE 39 Series - Relay interface modules

Low Voltage Products. Switches Automatic Transfer Switches

Solid State Timers Type F

Breakers and Switches. Switches Switch-disconnectors OT, OETL, OTDC and OTM

Thermal-Magnetic Circuit Breaker M1-..

THERMAL RELAYS, MOTORSTARTERS

CompactLogix Power Supplies Specifications

IEC style contactors - long electrical and mechanical life Complete range from mini-contactors to 630 Amp i n d u c t i ve AC3 ra t i n g s Wide

Transcription:

Data sheet Manual motor starter MS116 Manual motor starters are electromechanical protection devices for the main circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less against short-circuit, overload and phase failures. Fuse less protection with a manual motor starter saves costs, space and ensures a quick reaction under shortcircuit condition, by switching off the motor within milliseconds. Fuse less starter combinations are setup together with contactors. 2CDC241001V0013 Description Overload protection trip class 10 Phase loss sensitivity Disconnect function Temperature compensation from -25 +55 C djustable current setting for overload protection Suitable for three- and single-phase application Trip-free mechanism Clear switch position indication ON/OFF Order data MS116 screw terminal Setting range Type Trip class Order code Packing unit Weight per PCE PCE kg 0.10...0.16 MS116-0.16 10 1SM250000R1001 1 0.225 0.16...0.25 MS116-0.25 10 1SM250000R1002 1 0.225 0.25...0.40 MS116-0.4 10 1SM250000R1003 1 0.225 0.40...0.63 MS116-0.63 10 1SM250000R1004 1 0.225 0.63...1.00 MS116-1.0 10 1SM250000R1005 1 0.225 1.00...1.60 MS116-1.6 10 1SM250000R1006 1 0.265 1.60...2.50 MS116-2.5 10 1SM250000R1007 1 0.265 2.50...4.00 MS116-4.0 10 1SM250000R1008 1 0.265 4.00...6.30 MS116-6.3 10 1SM250000R1009 1 0.265 6.30...10.0 MS116-10 10 1SM250000R1010 1 0.265 8.00...12.0 MS116-12 10 1SM250000R1012 1 0.265 10.0...16.0 MS116-16 10 1SM250000R1011 1 0.265 16.0...20.0 MS116-20 10 1SM250000R1013 1 0.310 20.0...25.0 MS116-25 10 1SM250000R1014 1 0.310 25.0...32.0 MS116-32 10 1SM250000R1015 1 0.310 Note: MS116 with pre-assembled auxiliary contact HKF1-11, please order as follow 1SM250005Rxxxx

Functional description 1 Terminals 1L1, 3L2, 5L3 1 2 Test function 3 Current setting range / djustable current setting for overload protection 4 Terminals 2T1, 4T2, 6T3 2CDC242032F0013 2 3 4 pplication The manual motor starters protect the load and the installation against short-circuit and overload. They are three pole protection devices with thermal tripping elements for overload protection and electromagnetic tripping elements for shortcircuit protection. Furthermore, they provide a disconnect function for safely isolation of the installation and the supply and can be used for the manual switching of loads. The manual motor starters have a setting scale in amperes, which allows the direct adjusting of the device without any additional calculation. In compliance with international and national standards, the setting current is the rated current of the motor and not the tripping current (no tripping at 1.05 x I, tripping at 1.2 x I; I = setting current). Operation mode 2CDC242023F0009 2CDC242028F0013 2CDC242024F0009 Single-phase operation Single-phase operation Three-phase operation Wiring diagram 1L1 3L2 5L3 2T1 4T2 6T3 2CDC242025F0009 2-2CDC131025D0202

a Resistance and power loss per pole Type Setting range Resistance per pole Power loss per pole lower value upper value Ω at lower value W at upper value W MS116-0.16 0.10 0.16 66.00 0.7 1.7 MS116-0.25 0.16 0.25 25.50 0.7 1.7 MS116-0.4 0.25 0.40 10.38 0.7 1.7 MS116-0.63 0.40 0.63 4.36 0.7 1.7 MS116-1.0 0.63 1.00 1.605 0.7 1.7 MS116-1.6 1.00 1.60 0.648 0.7 1.7 MS116-2.5 1.60 2.50 0.292 0.7 1.8 MS116-4.0 2.50 4.00 0.114 0.7 1.8 MS116-6.3 4.00 6.30 0.046 0.7 1.8 MS116-10 6.30 10.0 0.024 0.9 2.4 MS116-12 8.00 12.0 0.016 1.0 2.3 MS116-16 10.0 16.0 0.011 1.1 2.8 MS116-20 16.0 20.0 0.0057 1.5 2.3 MS116-25 20.0 25.0 0.0045 1.8 2.8 MS116-32 25.0 32.0 0.0030 1.9 3.1 Technical diagram (Op/h) 140 120 100 switching frequency 80 60 40 20 t a = 3 s t a = 1.5 s t a = 5 s t a = 1 s t = 0.5 s 0 0 20 40 60 80 100 (%) duty ratio 2CDC232005F0211 Intermittent periodic duty, t a : Motor starting time 2CDC131025D0202-3

Dimensions in mm / inches 1.5 0.06" 5.5 0.22" 80.1 3.15" 70 2.76" 43.5 1.71" 1.5 0.06" 5.5 0.22" 79.9 3.15" 69.8 2.75" 43.3 1.7" 90 3.54" 1.7 0.07" 27.5 1.1" 75 2.95" 35 1.38" 45 1.77" 57.8 2.3" 97.8 3.85" 1.7 0.07" 27.5 1.1" 75 2.95" 35 1.38" 45 1.77" 57.8 2.3" 14 0.55" 14 45 1.77" 0.55" 2CDC242002F0010 14 0.55" 14 0.55" 45 1.77" 2CDC242001F0011 MS116 16 MS116 20 Ø 4.5 Ø 0.18" 9 0.35" 5.4 0.21" Ø 4.5 Ø 0.18" 9 0.35" 5.4 0.21" 122 110 122 110 4.8" 4.33" 4.8" 4.33" 17.5 0.69" 2CDC242003F0010 17.5 0.69" 2CDC242002F0011 MS116 16 with screw fixing kit FS116 (accessory) MS116 20 with screw fixing kit FS116 (accessory) 4-2CDC131025D0202

Main accessories for manual motor starter S1-M2-25 PS1-..-65 3-phase busbar up to 65 S1-M1-25 PS1-..-65 BS1-3 S1-M1-25 3-phase busbar up to 100 PS1-..-100 HK1 SK1 BS1-3 HK1 HK1 SK1 S1 CK1 MS116 1 HK1 CK1 U1 MS132 HKF1-11 1SBC500341F0000 2CDC131025D0202-5

Technical data IEC/EN Data at T = 40 C and at rated values, if nothing else indicated Main circuit 1L1-3L2-5L3 2T1-4T2-6T3 Rated operational voltage U e 690 V C - V DC Setting range - thermal overload protection see table Order data on page 1 Rated operational current I e see table below Rated instantaneous short-circuit current setting I i see table below Rated service short-circuit breaking capacity I cs see table Short-circuit breaking capacity and backup Rated ultimate short-circuit breaking capacity I cu fuses on page 8 Trip class see table Order data on page 1 Rated frequency 50/60 Hz Number of poles 3 Resistance per pole see table Resistance and power loss per pole on Power loss per pole page 3 Isolation data Rated impulse withstand voltage U imp 6 kv Rated insulation voltage U i 690 V Pollution degree 3 Electrical connection MS116 16 MS116 20 Connecting capacity solid 1/2 x 1... 4 mm² 1/2 x 1... 2.5 mm² 1/2 x 2.5 6 mm² stranded 1/2 x 1... 4 mm² 1/2 x 1... 2.5 mm² 1/2 x 2.5 6 mm² flexible with ferrule 1/2 x 0.75... 2.5 mm² 1/2 x 0.75 6 mm² flexible with insulated ferrule 1/2 x 0.75... 2.5 mm² 1/2 x 0.75 6 mm² flexible without ferrule 1/2 x 0.75... 2.5 mm² 1/2 x 1... 2.5 mm² 1/2 x 2.5 6 mm² Stripping length 9 mm 10 mm Tightening torque 0.8 1.2 Nm 2 Nm Recommended screw driver M3.5 M4 Type Rated instantaneous Rated operational current l e short-circuit current setting l i MS116-0.16 2.00 0.16 MS116-0.25 3.13 0.25 MS116-0.4 5.00 0.40 MS116-0.63 7.88 0.63 MS116-1.0 12.50 1.0 MS116-1.6 20.00 1.6 MS116-2.5 31.25 2.5 MS116-4.0 50.00 4.0 MS116-6.3 78.75 6.3 MS116-10 150 10 MS116-12 180 12 MS116-16 240 16 MS116-20 300 20 MS116-25 375 25 MS116-32 480 32 6-2CDC131025D0202

General data Mechanical durability 100000 Electrical durability MS116 16 100000 MS116 20 50000 Duty time 100 % Operating frequency without early tripping up to 15 operations/h or 60 operations/h with Dimensions (W x H x D) see drawing on page 6 40 % duty ratio, if the motor breaking current 6 x I n and the motor starting time does not exceed 1 s Weight see table Order data on page 1 Mounting DIN-rail (EN 60715) Mounting position Group mounting position 1-6 (optional for single mounting) on request Minimum distance to other units same type horizontal 0 mm vertical 150 mm Minimum distance to electrical conductive board horizontal, up to 400 V 0 mm horizontal, up to 690 V vertical Degree of protection housing IP20 Utilization category Maximum operating altitude permissible Maximum operating frequency main circuit terminals > 1.5 mm 75 mm IP10 2000 m 170 cycles/h Electromagnetic compatibility Electromagnetic compatibility not applicable Environmental data mbient air temperature Operation open - compensated -25... +55 C open -25... +70 C enclosed (IB132) 0... +40 C Storage -50... +80 C mbient air temperature compensation acc. to IEC/EN 60947-4-1 Resistance to vibrations acc. to IEC 60068-2-6 5g / 3... 150 Hz Resistance to shock acc. to IEC 60068-2-27 25g / 11 ms Standards / directives Standards IEC/EN 60947-1 IEC/EN 60947-2 IEC/EN 60947-4-1 UL 60947-1 UL 60947-4-1 Low Voltage Directive 2006/95/EC EMC Directive 2004/108/EC RoHS Directive 2002/95/EC 2CDC131025D0202-7

Short-circuit breaking capacity and back-up fuses l CS Rated service short-circuit breaking capacity l CU I CC Rated ultimate short-circuit breaking capacity Prospective short-circuit current at installation location Note: Maximum rated current of the back-up fuses if I CC > I CS Type 230 V C 400 V C 440 V C 500 V C 690 V C I CS I CU gg, am I CS I CU gg, am I CS I CU gg, am I CS I CU gg, am I CS I CU gg, am MS116-0.16 MS116-0.25 MS116-0.4 MS116-0.63 No back-up fuse required up to I CC = 30 MS116-1.0 MS116-1.6 No back-up fuse required up to I CC = 50 MS116-2.5 10 10 25 10 10 25 5 5 25 MS116-4.0 6 6 25 6 6 25 2 2 25 MS116-6.3 6 6 63 6 6 63 2 2 40 MS116-10 6 6 63 6 6 63 2 2 50 MS116-12 25 25 80 25 25 80 6 6 63 6 6 63 2 2 50 MS116-16 16 16 80 16 16 80 6 6 63 4 4 63 2 2 63 MS116-20 10 15 125 10 15 125 3 6 125 3 4 125 2 2 80 MS116-25 10 15 125 10 15 125 3 6 125 3 4 125 2 2 100 MS116-32 10 10 125 10 10 125 3 6 125 3 4 125 2 2 100 8-2CDC131025D0202

Technical data UL/CS Main circuit Maximum operational voltage 600 V Manual Motor Controller ratings see table UL 508 Manual Motor Controller on page 10 Motor ratings Horse power see table below Full load amps (FL) see table below Locked rotor amps (LR) see table below Electrical connection MS116 16 MS116 20 Connecting capacity stranded 1/2 x WG 16... 12 1/2 x WG 16... 8 flexible without ferrule 1/2 x WG 16... 12 1/2 x WG 16... 8 Stripping length 9 mm 10 mm Tightening torque 10... 12 lb-in 18 lb-in Recommended screw driver M3.5 M4 Motor rating, single phase hp Horse power FL Full load amps LR Locked rotor amps Type 120 VC 220-240 VC hp FL LR hp FL LR MS116-0.16-0.16 0.96-0.16 0.96 MS116-0.25-0.25 1.5-0.25 1.5 MS116-0.4-0.4 2.4-0.4 2.4 MS116-0.63-0.63 3.78-0.63 3.78 MS116-1.0-1 6-1.0 6.0 MS116-1.6-1.6 9.6 1/10 1.5 - MS116-2.5-2.5 15 1/6 2.2 - MS116-4.0 1/8 4 24 1/3 3.6 - MS116-6.3 1/4 6.3 37.8 1/2 4.9 - MS116-10 1/2 9.8 58.8 1-1/2 10 - MS116-12 1/2 9.8 58.8 2 12 - MS116-16 1 16 96 2 12 - MS116-20 1-1/2 20 120 3 17 92 MS116-25 2 24 144 3 17 127 MS116-32 2 24 144 5 28 162 Motor rating, three phase hp Horse power FL Full load amps LR Locked rotor amps Type 220-240 VC 440-480 VC 550-600 VC hp FL LR hp FL LR hp FL LR MS116-0.16-0.16 0.96-0.16 0.96-0.16 0.96 MS116-0.25-0.25 1.5-0.25 1.5-0.25 1.5 MS116-0.4-0.4 2.4-0.4 2.4-0.4 2.4 MS116-0.63-0.63 3.78-0.63 3.78-0.63 3.78 MS116-1.0-1.0 6.0 1.0 6.0 1/2 0.9 8 MS116-1.6-1.6 9.6 3/4 1.6 12.5 3/4 1.3 10 MS116-2.5 1/2 2.2 20 1 2.1 15 1-1/2 2.4 16 MS116-4.0 1 4.2 30 2 3.4 25 3 3.9 25.6 MS116-6.3 1-1/2 6.4 40 3 4.8 32 5 6.1 36.8 MS116-10 3 9.6 64 5 7.6 46 7-1/2 9 50.8 MS116-12 3 9.6 64 7-1/2 11 63.5 10 11 64.8 MS116-16 5 15.2 92 10 20 81 10 11 64.8 MS116-20 5 15.2 92 10 14 81 15 17 93 MS116-25 7-1/2 22 127 15 21 116 20 22 116 MS116-32 10 28 162 20 27 145 25 27 146 2CDC131025D0202-9

UL 508 Manual Motor Controller Type Maximum fuse type Maximum short-circuit current K5 o. RK5 per UL/NEC for motor disconnect 1) for group installation 480 V / 600 V 480 V 600 V 480 V 600 V MS116-0.16 100 30 5 18 5 MS116-0.25 100 30 5 18 5 MS116-0.4 100 30 5 18 5 MS116-0.63 100 30 5 18 5 MS116-1.0 100 30 5 18 5 MS116-1.6 100 30 5 18 5 MS116-2.5 100 30 5 18 5 MS116-4.0 100 18 5 18 5 MS116-6.3 100 18 5 18 5 MS116-10 100 18 5 18 5 MS116-12 100 18 5 18 5 MS116-16 100 18 5 18 5 MS116-20 100 18 5 18 5 MS116-25 100 18 5 18 5 MS116-32 100 18 5 18 5 1) Suitable as motor disconnect only when provided with padlock S1 or S3... 10-2CDC131025D0202

Contact us BB STOTZ-KONTKT GmbH Eppelheimer Straße 82 69123 Heidelberg, Germany Phone: +49 (0) 6221 7 01-0 Fax: +49 (0) 6221 7 01-13 25 E-Mail: info.desto@de.abb.com You can find the address of your local sales organization on the BB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. BB G does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. ny reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of BB G. Document number 2CDC131025D0202 (04.2016) Copyright 2016 BB ll rights reserved