technical data air conditioning systems RXS20-25-35E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air



Similar documents
Air Conditioners Technical Data

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

HP switch LP switch Discharge thermo Comp. Surface thermo

SERVICE MANUAL MUZ-GE09NA MUZ-GE12NA MUZ-GE15NA MUZ-GE18NA MUZ-GE24NA MUY-GE09NA MUY-GE12NA MUY-GE15NA MUY-GE18NA MUY-GE24NA OUTDOOR UNIT

Air Conditioners Technical Data

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

Appendix - Controllers 179

TECHNICAL & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER + SAP C181MA + SAP C181GA + SAP C181BA + SAP C241MA + SAP C241BA FILE NO.

Cooling kw Heating kw

SERVICE MANUAL SPLIT SYSTEM ROOM AIR CONDITIONER SHARP CORPORATION SHARP CORPORATION CONTENTS

SERVICE MANUAL OUTDOOR UNIT MUZ-A09NA,- 1,- U1,- U2 MUZ-A12NA,- U1 MUZ-A15NA,- U1 MUZ-A17NA,- U1 MUY-A15NA MUY-A17NA MUY-A24NA,- 1,- U1,- U2

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

Europe Inverter Single 50Hz(R410A) 5RMI0-04B(Replace : 5RMI0-04A)

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

ECOCIAT. Domestic hot water heat recovery unit

DESIGN & TECHNICAL MANUAL

york air-conditioning products Residential & VRF News 2015

DESIGN & TECHNICAL MANUAL

TECHNICAL & SERVICE MANUAL WINDOW TYPE AIR CONDITIONER SA 79G SA 99G FILE NO. SA 79G SA 99G REFERENCE NO. SM700402

SiUS Service Manual. Inverter Pair Wall Mounted Type K-Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Indoor coil is too warm in cooling mode or too cold in heating mode. Reversing valve or coil thermistor is faulty

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

MAC-120HE-01 Air-Cooled Chiller

Daikin Altherma hybrid heat pump. The natural combination

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

SiUS Service Manual. Inverter Pair FTXS-L Series FDXS-L Series. [Applied Models] Inverter Pair : Cooling Only Inverter Pair : Heat Pump

AquaFREE system. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE

Unico Inverter. Unique and efficient.

CU-2E15LBE CU-2E18LBE CU-3E18LBE CU-4E23LBE

SERVICE MANUAL MUZ-FE09NA MUZ-FE12NA MUZ-FE18NA OUTDOOR UNIT. No. OBH543 REVISED EDITION-A. Models HFC

AIR-CONDITIONER SPLIT TYPE

SiBE D-Series / E-Series. [Applied Models] Inverter Multi : Cooling Only Inverter Multi : Heat Pump

AIR-COOLED CHILLERS APPLIED SYSTEMS. EUWA*5-24KAZW - EUWY*5-24KAZW -

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

Air Conditioners Technical Data

AquaFREE System. Technical Catalogue. Outdoor units: RAS-(3~5)HVRNE RAS-(4/5)HRNE. Indoor units: RWM-(3~5)FSN1E RWM-(3~5)FSN1E-(4.

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

Si10-417_C. Pocket Manual. Service Diagnosis SPLIT & MULTI

SERVICE MANUAL. Room Air Conditioner Multi Split type Outdoor unit /R410A DC Inverter/

DC INVERTER SPLIT SYSTEM AIR CONDITIONER

Versati Air to Water Heat Pump

Air Conditioning For Large Buildings

Earth can hardly wait for a change in the atmosphere. Nor can we. By making air conditioning supremely energy-efficient, quiet, easy to install, and

SERVICE MANUAL MXZ-2A20NA MXZ-2A20NA - MXZ-3A30NA MXZ-3A30NA - MXZ-4A36NA OUTDOOR UNIT. No. OB444. Models HFC. Inverter-controlled multi system type

SERVICE MANUAL MU-A09WA MU-A12WA MU-A12WA- 1 OUTDOOR UNIT. No. OB449. Wireless type Models HFC. Revision : A SPLIT-TYPE AIR CONDITIONERS

emura Form. redefined.

URURU SARARA: THE AIR CONDITIONER THAT COOLS, HEATS, HUMIDIFIES, DEHUMIDIFIES, PURIFIES AND VENTILATES;

TEST REPORT #44. System Drop-in Tests of Refrigerant R-32 in Single Packaged Vertical Heat Pump (SPVH)

DC INVERTER MULTI-SYSTEM AIR CONDITIONER

How To Power A Car With A Fan And A Fan (Power)

LG Air Conditioning - Universal Split Fault Codes Sheet. Universal Split Systems

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Hot Water. Heat pump water heaters. Residential and Commercial R410a

14. Troubleshooting Guide

AIR CONDITIONER SERVICE MANUAL. Please read this manual carefully before operating your set and retain it for future reference. System.

Technical Service Manual. Version One

Failure code manual. content

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. ELECTRICAL SCHEMATIC DIAGRAM EXPLOSION VIEW 16 6

PANASONIC TROUBLE SHOOTING GUIDE

Inverter Air Conditioning for Light Commercial Use

The natural ombination

Daikin Altherma. hybrid heat pump. The natural combination

DM en. Service manual MIV V5 HEAT PUMP DC INVERTER R410A MVUH252B-VA3 MVUH280B-VA3 MVUH335B-VA3 MVUH400B-VA3 MVUH450B-VA3 MVUH500B-VA3

Operating Instructions Split System Air Conditioner

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

Split Type Inverter Room Air Conditioner OPERATION MANUAL

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

CLOSE CONTROL SYSTEM. PFD series provide you with highly reliable computer room cooling system. High Reliability

Models Utopia ES Utopia IVX Utopia DC Inverter Utopia Fixed Speed Utopia Centrifugal

FTQ. Daikin Inverter Ducted Heat Pump

NEW 3-PIPE ECOi MF2 SERIES

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

Submitted to Reference Approval Construction Unit Designation Schedule #

CRAC Precision climate control units for data centres

Split System Air Conditioners SkyAir Inverter

Air conditioners Heating & Cooling

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

How To Measure Temperature On A Thermostat

Conlift1, Conlift2, Conlift2 ph+

SWIMMING POOL HEAT PUMP

LOBOY 16 AIR CONDITIONERS

Multi Air Conditioner SVC MANUAL(Exploded View)

TWE+TTA TWE+TWA T.R.

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

CA SERIES. Available in sizes from 3/4 through 1-1/4 tons the CA Series offers a wide range of features such as:

MDT5N25 & MTD5N40 SERVICE PARTS

AIR-TO-WATER HEAT PUMP (50Hz/R410A) 5BPU0-03C(Replace:5BPU0-03B)

ASHRAE Boston Chapter Meeting Designing AC Refrigeration Systems Lessons Learned February 11, 2014

U-MATCH Air Conditioners. Service Manual. T1/R410a/50Hz

INVERTER WALL MOUNTED TYPE ROOM AIR-CONDITIONER ( Split system, air to air heat pump type )

Schedule 3(A) Room Air Conditioners

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Split System Heat Pump Product Data

Air Conditioning for Small and Medium-size Buildings

Transcription:

technical data RXS20-25-35E FBQ-B8V-B8V3B (single phase) Split Heat Pump Condensing Units air conditioning systems Split Sky Air

Outdoor Units R-40A RXS-E2VB Split Sky Air Outdoor Units Features O u t d o o r U n i S p l i t S k y R X S - E 2 V B R - 4 0 A Outdoor units for pair application Daikin outdoor units are neat and sturdy and can be mounted easily on a roof or terrace or simply placed against an outside wall. Outdoor units are fitted with a swing compressor, renowned for its low noise and high energy efficiency

2 Specifications Outdoor Units R-40A RXS-E2VB 2- NOMINAL CAPACITY AND NOMINAL INPUT RXS20E2VB RXS25E2VB RXS35E2VB For combination indoor units + outdoor units Cooling capacity Heating capacity Units FTXS20D3VMW FTXS25D3VMW FTXS35D3VMW Minimum kw.2.2.2 Standard kw 2.0 2.5 3.4 Maximum kw 2.6 3.0 3.8 Minimum kw.2.2.2 Standard kw 2.7 3.4 4.0 Maximum kw 4. 4.5 5.0 Nominal input Cooling Minimum kw 0.30 0.3 0.30 For combination indoor units + outdoor units Cooling capacity Heating capacity Standard kw 0.48 0.6.00 Maximum kw 0.82 0.8.22 Heating Minimum kw 0.29 0.29 0.29 Standard kw 0.65 0.83.08 Maximum kw.29.34.55 EER Nominal 4.7 4.7 3.40 COP Nominal 4.5 4.0 3.70 Energy Labeling Directive Cooling A A Heating A A Annual energy consumption kwh 240 300 500 Units FTXS20D3VML FTXS25D3VML FTXS35D3VML Minimum kw.2.2.2 Standard kw 2.0 2.5 3.4 Maximum kw 2.6 3.0 3.8 Minimum kw.2.2.2 Standard kw 2.7 3.4 4.0 Maximum kw 4. 4.5 5.0 Nominal input Cooling Minimum kw 0.30 0.3 0.30 For combination indoor units + outdoor units Cooling capacity Heating capacity Standard kw 0.48 0.6.00 Maximum kw 0.82 0.8.22 Heating Minimum kw 0.29 0.29 0.29 Standard kw 0.65 0.83.08 Maximum kw.29.34.55 EER Nominal 4.7 4.7 3.40 COP Nominal 4.5 4.0 3.70 Energy Labeling Directive Cooling A A Heating A A Annual energy consumption kwh 240 300 500 Units FDXS25EAVMB FDXS35EAVMB Minimum kw.3.4 Standard kw 2.4 3.4 Maximum kw 3.0 3.8 Minimum kw.3.4 Standard kw 3.2 4.0 Maximum kw 4.5 5.0 Nominal input Cooling Standard kw 0.69.09 For combination indoor units + outdoor units Heating Standard kw 0.9.8 EER Nominal 3.48 3.2 COP Nominal 3.52 3.39 Energy Labeling Directive Cooling A B Heating B C Annual energy consumption kwh 345 545 Units FLXS25BAVMB FLXS35BAVMB 3 2 Split Sky Air Outdoor Units 2

2 Specifications Outdoor Units R-40A RXS-E2VB 2 2- NOMINAL CAPACITY AND NOMINAL INPUT RXS20E2VB RXS25E2VB RXS35E2VB Cooling capacity Heating capacity Minimum kw.2.2 Standard kw 2.5 3.5 Maximum kw 3.0 3.8 Minimum kw.2.4 Standard kw 3.4 4.0 Maximum kw 4.5 5.0 Nominal input Cooling Minimum kw 0.30 0.30 For combination indoor units + outdoor units Cooling capacity Heating capacity Standard kw 0.65.3 Maximum kw 0.86.26 Heating Minimum kw 0.29 0.29 Standard kw 0.98.23 Maximum kw.49.85 EER Nominal 3.85 3.0 COP Nominal 3.47 3.25 Energy Labeling Directive Cooling A B Heating B C Annual energy consumption kwh 325 565 Units FFQ25B8VB FFQ35B8VB Standard kw 2.5 3.4 Standard kw 3.2 4.0 Nominal input Cooling Standard kw 0.73.0 For combination indoor units + outdoor units Cooling capacity Heating capacity Heating Standard kw 0.92.20 EER Nominal 3.42 3.09 COP Nominal 3.48 3.33 Energy Labeling Directive Cooling A B Heating B C Annual energy consumption kwh 365 550 Units FBQ35B8V Standard kw 3.4 Standard kw 4.0 Nominal input Cooling Standard kw.7 For combination indoor units + outdoor units Cooling capacity Heating capacity Heating Standard kw.22 EER Nominal 2.9 COP Nominal 3.28 Energy Labeling Directive Cooling Heating Annual energy consumption kwh 585 Units C C FHQ35BVVB Minimum kw.4 Standard kw 3.4 Maximum kw 3.7 Minimum kw.2 Standard kw 4.0 Maximum kw 5.0 Nominal input Cooling Standard kw.05 For combination indoor units + outdoor units Heating Standard kw. EER Nominal 3.24 COP Nominal 3.60 Energy Labeling Directive Cooling Heating Annual energy consumption kwh 525 A B 3 Split Sky Air Outdoor Units

2 Specifications Outdoor Units R-40A RXS-E2VB 2-2 TECHNICAL SPECIFICATIONS RXS20E2VB RXS25E2VB RXS35E2VB Casing Colour Ivory White Dimensions Unit Height mm 550 550 550 Width mm 765 765 765 Depth mm 285 285 285 Packing Height mm 589 67 67 Width mm 882 882 882 Depth mm 363 363 363 Weight Unit kg 30 32 32 Heat Exchanger Packed Unit kg 35 38 38 Dimensions Length mm 828 805 805 Tube type Nr of Rows 2 2 Fin Pitch mm.4.4.4 Nr of Stages 24 24 24 Hi-Xa(7) Fin Type Waffle fin Treatment Anti-corrosion treatment (PE) Fan Type Propeller Motor Quantity Air Flow Rate (nominal at 230V) Cooling m³/min 36.2(H) - 25.7(L) 33.5(H) - 23.4(L) 33.5(H) - 23.4(L) Heating m³/min 32.6(H) - 30.6(L) 30.2(H) - 28.3(L) 30.2(H) - 28.3(L) Motor Quantity Speed (nominal) Model D238-28 Cooling rpm 860(H) - 620(L) 860(H) - 620(L) Heating rpm 860(H) - 80(L) 860(H) - 80(L) Fan Motor Output W 50 50 50 Compressor Quantity Operation Range Sound Level (nominal) Sound Level (Night quiet) Motor Model YC23NXD#C Type Motor Output Hermetically sealed swing compressor W 600 600 600 Cooling Min CDB -0-0 -0 Max CDB +46 +46 +46 Heating Min CWB -5-5 -5 Cooling Heating Max CWB +20 +20 +20 Sound Power Sound Pressure Sound Pressure dba 6(H) 6(H) 62(H) dba 46(H) - 43(L) 46(H)- 43(L) 47(H) - 44(L) dba 47(H) - 44(L) 62(H) 48(H) - 45(L) Sound Pressure dba 47(H) - 44(L) Refrigerant Type R-40A Charge kg 0.8.0.0 Refrigerant Oil Type FVC50K Charged Volume l 0.375 0.375 0.375 3 2 Split Sky Air Outdoor Units 4

2 Specifications Outdoor Units R-40A RXS-E2VB 2 2-2 TECHNICAL SPECIFICATIONS RXS20E2VB RXS25E2VB RXS35E2VB Piping connections Standard Accessories Notes Liquid (OD) Gas Drain Diameter (OD) Diameter (OD) Diameter (OD) mm 6.35 6.35 6.35 mm 9.5 9.5 9.5 mm 8 8 8 Piping Length Maximum m 20 20 20 Additional Refrigerant Charge Installation height difference Chargele ss m 0 0 kg/m 0.02/>0m Maximum m 5 5 5 Heat Insulation Both liquid and gas pipes Both liquid and gas pipes Item Installation manual Quantity Item Drain plug Drain plug Quantity Nominal cooling capacities are based on : indoor temperature : 270CDB, 90CWB, outdoor temperature : 350CDB, equivalent refrigerant piping : 7.5m, level difference : 0m. 2-3 ELECTRICAL SPECIFICATIONS RXS20E2VB RXS25E2VB RXS35E2VB Power Supply Name V Current Wiring connections Phase Frequency Hz 50 50 50 Voltage V 220-240 Nominal running current (RLA) Cooling (A) Heating (A) Starting current (cooling/ heating) A 2.44 3.4 4.42 A 3.34 3.94 4.72 A 3.7 4.3 5. Z-max List No requirements Maximum Running Current A 3.33/4.3 4.6/4.9 For Power Supply For connection with indoor Quantity 3 3 3 Quantity 4 4 4 Remark (including earth wiring) 5 Split Sky Air Outdoor Units

4 Electrical data Outdoor Units R-40A RXS-E2VB 4 Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 2.3 Max. 50Hz 264V FTXS20D3VMW/L RXS20E2VB 50-230 9.75 0 40 2. 23 0.20 40 0.4 Min. 50Hz 98V 50-240 2.0 MCA MFA RHz RLA OFM IFM FLA W : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W) 3D055006. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 3.0 Max. 50Hz 264V FTXS25D3VMW/L RXS25E2VB 50-230 9.75 0 48.5 2.8 23 0.22 40 0.4 Min. 50Hz 98V 50-240 2.7 3D055008 MCA MFA RHz RLA OFM IFM FLA W : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W). RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. 7 Split Sky Air Outdoor Units

4 Electrical data Outdoor Units R-40A RXS-E2VB Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 3.2 Max. 50Hz 264V FLXS25BAVMB RXS25E2VB 50-230 9.75 0 50 3. 23 0.6 34 0.34 Min. 50Hz 98V 50-240 2.9 MCA MFA RHz RLA OFM IFM FLA W : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W) 3D05500B. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. 3 4 Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 3.5 Max. 50Hz 264V FDXS25EAVMB RXS25E2VB 50-230 9.75 0 54.5 3.3 23 0.6 62 0.5 Min. 50Hz 98V 50-240 3.2 3D05500B MCA MFA RHz RLA OFM IFM FLA W : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W). RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 8

4 Electrical data Outdoor Units R-40A RXS-E2VB 4 MCA MFA RHz RLA OFM IFM FLA W Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 3.7 Max. 50Hz 264V FFQ25B8VB RXS25E2VB 50-230 9.75 0 55 3.5 23 0.6 55 0.6 Min. 50Hz 98V 50-240 3.4 : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W) 3D05500B. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 4.3 Max. 50Hz 264V FTXS35D3VMW/L RXS35E2VB 50-230 9.75 0 75 4. 23 0.22 40 0.4 Min. 50Hz 98V 50-240 3.9 3D055009 MCA MFA RHz RLA OFM IFM FLA W : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W). RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. 9 Split Sky Air Outdoor Units

4 Electrical data Outdoor Units R-40A RXS-E2VB Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 4.8 Max. 50Hz 264V FLXS35BAVMB RXS35E2VB 50-230 9.75 0 82 4.6 23 0.22 34 0.38 Min. 50Hz 98V 50-240 4.4 MCA MFA RHz RLA OFM IFM FLA W : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W) 3D0550B. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. 3 4 Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 4.7 Max. 50Hz 264V FDXS35EAVMB RXS35E2VB 50-230 9.75 0 78 4.5 23 0.22 62 0.5 Min. 50Hz 98V 50-240 4.3 3D0550B MCA MFA RHz RLA OFM IFM FLA W : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W). RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 0

4 Electrical data Outdoor Units R-40A RXS-E2VB 4 MCA MFA RHz RLA OFM IFM FLA W Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 5. Max. 50Hz 264V FBQ35B8V RXS35E2V2B 50-230 9.75 0 80 4.9 23 0.6 65 0.5 Min. 50Hz 98V 50-240 4.7 : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W) 3D0550B. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 4.8 Max. 50Hz 264V FCQ35B8V RXS35E2V2B 50-230 9.75 0 78 4.5 23 0.6 45 0.6 Min. 50Hz 98V 50-240 4.3 3D0550B MCA MFA RHz RLA OFM IFM FLA W : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W). RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units

4 Electrical data Outdoor Units R-40A RXS-E2VB MCA MFA RHz RLA OFM IFM FLA W Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 4.8 Max. 50Hz 264V FFQ35B8VB RXS35E2V2B 50-230 9.75 0 79 4.6 23 0.6 55 0.6 Min. 50Hz 98V 50-240 4.4 : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W) 3D0550B. RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. 3 4 Representative unit combination Power supply Comp. OFM IFM unit Outdoor unit Hz-volts Voltage range MCA MFA RHz RLA W FLA W FLA 50-220 4.5 Max. 50Hz 264V FHQ35BVVB RXS35E2VB 50-230 9.75 0 76 4.3 23 0.22 62 0.6 Min. 50Hz 98V 50-240 4. 3D0550B MCA MFA RHz RLA OFM IFM FLA W : Min. Circuit Amps (A) : Max. Fuse Amps (A) : Rated operating frequency (Hz) : Rated Load Amps (A) : Outdoor Fan Motor : Fan Motor : Full Load Amps (A) : Rated motor output (W). RLA is based on the following conditions: temp.: 27 CDB/9.0 CWB Outdoor temp. : 35 CDB 2. Maximum allowable voltage unbalance between phases is 2% 3. Select wire size based on the larger value of MCA. 4. Instead of fuse, use circuit breaker. 5. For more details concerning conditional connections, see http://extranet.daikineurope.com, select E-Data Books. Finally, click on the document title of your choice. Split Sky Air Outdoor Units 2

Outdoor Units R-40A RXS-E2VB 5 5 Capacity tables 5 - Cooling/Heating capacity tables FTXS20D3VMW/L+RXS20E2VB Cooling 50Hz 220-240V AFR 8.7 BF 0.2 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50Hz 220-240V AFR 9.4 EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D055032 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. 3 Split Sky Air Outdoor Units

Outdoor Units R-40A RXS-E2VB 5 Capacity tables 5 - Cooling/Heating capacity tables FTXS25D3VMW/L+RXS25E2VB Cooling 50Hz 220-240V AFR 8.7 BF 0.24 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 3 5 Heating 50Hz 220-240V AFR 9.4 EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D055033 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. Split Sky Air Outdoor Units 4

Outdoor Units R-40A RXS-E2VB 5 5 Capacity tables 5 - Cooling/Heating capacity tables FLXS25BAVMB+RXS25E2VB Cooling 50Hz 220-240V AFR 7.6 BF 0.32 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50Hz 220-240V AFR 9.2 EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D055037 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. 5 Split Sky Air Outdoor Units

Outdoor Units R-40A RXS-E2VB 5 Capacity tables 5 - Cooling/Heating capacity tables FDXS25EAVMB+RXS25E2VB Cooling 50Hz 220-240V AFR 8.7 BF 0.7 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 3 5 Heating 50Hz 220-240V AFR 8.7 EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D055042 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. Split Sky Air Outdoor Units 6

Outdoor Units R-40A RXS-E2VB 5 5 Capacity tables 5 - Cooling/Heating capacity tables FFQ25B8VB+RXS25E2VB Cooling 50Hz 220-240V AFR 9 BF 0.24 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50Hz 220-240V AFR 9 Outdoor temperature ( CWB) EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D055487 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. 7 Split Sky Air Outdoor Units

Outdoor Units R-40A RXS-E2VB 5 Capacity tables 5 - Cooling/Heating capacity tables FTXS35D3VMW/L+RXS35E2VB Cooling 50Hz 220-240V AFR 8.9 BF 0.24 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 3 5 Heating 50Hz 220-240V AFR 9.7 EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D055034 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. Split Sky Air Outdoor Units 8

Outdoor Units R-40A RXS-E2VB 5 5 Capacity tables 5 - Cooling/Heating capacity tables FLXS35BAVMB+RXS35E2VB Cooling 50Hz 220-240V AFR 8.6 BF 0.35 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50Hz 220-240V AFR 9.8 EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D055039 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. 9 Split Sky Air Outdoor Units

Outdoor Units R-40A RXS-E2VB 5 Capacity tables 5 - Cooling/Heating capacity tables FDXS35EAVMB+RXS35E2VB Cooling 50Hz 220-240V AFR 8.7 BF 0.7 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 3 5 Heating 50Hz 220-240V AFR 8.7 EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D055043 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. Split Sky Air Outdoor Units 20

Outdoor Units R-40A RXS-E2VB 5 5 Capacity tables 5 - Cooling/Heating capacity tables FBQ35B8V+RXS35E2VB Cooling 50Hz 220-240V AFR.5 BF 0.5 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50Hz 220-240V AFR.5 Outdoor temperature ( CWB) EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D055493 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. 2 Split Sky Air Outdoor Units

Outdoor Units R-40A RXS-E2VB 5 Capacity tables 5 - Cooling/Heating capacity tables FCQ35B8V+RXS35E2VB Cooling 50Hz 220-240V AFR 4 BF 0.6 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 3 5 Heating 50Hz 220-240V AFR 4 Outdoor temperature ( CWB) EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D05549 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. Split Sky Air Outdoor Units 22

Outdoor Units R-40A RXS-E2VB 5 5 Capacity tables 5 - Cooling/Heating capacity tables FHQ35BVVB+RXS35E2VB Cooling 50Hz 220-240V AFR 0 BF 0.25 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI Heating 50Hz 220-240V AFR 0 Outdoor temperature ( CWB) EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D055489 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. 23 Split Sky Air Outdoor Units

Outdoor Units R-40A RXS-E2VB 5 Capacity tables 5 - Cooling/Heating capacity tables FHQ35BVVB+RXS35E2VB Cooling 50Hz 220-240V AFR 3 BF 0.20 EWB EDB 20 25 30 32 35 40 ( C) ( C) TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI TC SHC PI 3 5 Heating 50Hz 220-240V AFR 3 EDB -0-5 0 6 0 ( C) TC PI TC PI TC PI TC PI TC PI 3D055046 AFR: Air flow rate (m 3 /min) BF: Bypass factor EWB: Entering wet bulb temp. ( C) EDB: Entering dry bulb temp. ( C) TC: Total capacity (kw) SHC: Sensible heating capacity (kw) PI: Power input (kw). Capacities are based on the following conditions: () Corresponding refrigerant piping length: 7.5 m (2) Level difference: 0 m 2. shows nominal (rated) capacities and power input. Split Sky Air Outdoor Units 24

Outdoor Units R-40A RXS-E2VB 6 Dimensional drawing & centre of gravity 6 - Dimensional drawing RXS20-35E2VB unit (mm) 6 Drain outlet (I.D. J 5.9 hose for connection) 4 x holes for anchor bolts (M8 or M0) Minimum space for air passage Wall height on air outlet side = less than 200 Handle Brand name label Outdoor air thermistor Name plate Wiring inlet Liquid stop valve (J 6.4 CuT) Service port In case of removing stop valve cover Gas stop valve (J 2.7 CuT) 3D04800H 25 Split Sky Air Outdoor Units

Outdoor Units R-40A RXS-E2VB 6 Dimensional drawing & centre of gravity 6-2 Centre of gravity RXS20-35E2VB 3 6 4D04407M Split Sky Air Outdoor Units 26

7 Piping diagram Outdoor Units R-40A RXS-E2VB RXS20E2VB Outdoor unit 7 Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Motor operated valve Muffler with filter Muffler with filter Propeller fan Muffler with filter Four way valve normally: OFF Field piping Muffler Liquid stop valve Discharge pipe thermistor Compressor Accumulator Muffler Gas stop valve Field piping Refrigerant flow Cooling Heating 3D04735D RXS25-35E2VB Outdoor unit Heat exchanger Outdoor temperature thermistor Heat exchanger thermistor Motor operated valve Muffler with filter Muffler with filter Propeller fan Muffler with filter Four way valve normally: OFF Field piping Muffler Liquid stop valve Discharge pipe thermistor Compressor Accumulator Muffler Gas stop valve Field piping Refrigerant flow Cooling Heating 3D04736E 27 Split Sky Air Outdoor Units

Outdoor Units R-40A RXS-E2VB 8 Wiring diagram 8 - Wiring diagram RXS20-35E2VB 3 g Field wiring 8 NOTE. Refer to the nameplate for the power requirements. Outdoor R : Protective earth C74,C75 C94,C95,C00 : Capacitor DB,DB2 : Diode bridge FU,FU2,FU3 : Fuse IC : Solid state relay IPM : Intelligent power module L : Live L : Coil LR : Reactor MC : Compressor motor MF : Fan motor MRCW,MRM0,MRM20 : Magnetic relay In case of cooling only type N : Neutral PCB,PCB2 : Printed circuit board QL : Overload protector RT,R2T,R3T,R2T : Thermistor S0,S,S20 S30,S40,S70 S80,S90,S9 HC3,HC4,HL3,HN3: Connector In case of heat pump type SA V,V2,V3 XM YE YR ZC,Z2C (outdoor) (discharge) (Condenser) : Surge arrester : Varistor : Terminal strip : Electronic expansion valve coil : Reversing solenoide valve coil : Ferrite core 3D04707H Split Sky Air Outdoor Units 28

Outdoor Units R-40A RXS-E2VB 9 Sound data 9 - Sound pressure spectrum RXS20-25E2VB (Cooling) RXS20-25E2VB (Heating) 9 Octave band sound pressure level Octave band sound pressure level approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D05297C Octave band center frequency (Hz) 3D05297C Octave band center frequency (Hz) Measure in anechoic room 2 Operation noise differs with operation and ambient conditions. 3 The operation noise measuring method is in accordance with JISC962 Location of microphone Measure in anechoic room 2 Operation noise differs with operation and ambient conditions. 3 The operation noise measuring method is in accordance with JISC962 Location of microphone Legend Legend 50Hz, 220-240V 50Hz, 220-240V RXS35E2VB (Cooling) RXS35E2VB (Heating) Octave band sound pressure level Octave band sound pressure level approximate threshold hearing for continuous noise approximate threshold hearing for continuous noise 4D052972C Octave band center frequency (Hz) 3D052972C Octave band center frequency (Hz) Measure in anechoic room 2 Operation noise differs with operation and ambient conditions. 3 The operation noise measuring method is in accordance with JISC962 Location of microphone Measure in anechoic room 2 Operation noise differs with operation and ambient conditions. 3 The operation noise measuring method is in accordance with JISC962 Location of microphone Legend Legend 50Hz, 220-240V 50Hz, 220-240V 29 Split Sky Air Outdoor Units

0 Operation range Outdoor Units R-40A RXS-E2VB RXS20-35E2VB 3 Cooling Heating 0 Outdoor temp. ( CDB) Continuous operation Pull-down period Outdoor temp. ( CWB) Continuous operation (-5 CDB) temp. ( CWB) temp. ( CDB) Notes: The graphs are based on the following conditions: + Equivalent piping length 7.5 m + Level difference 0 m + Air flow rate high 3D039536J Split Sky Air Outdoor Units 30