Fire Alarm Panel (Conventional) CONVENTIONAL FIRE ALARM SYSTEM a. 2, 4,8 to 16 zones b. Minimum 20 detectors per zone c. Compatibility with virtually all known conventional, ionization, optical & heat detector range d. LCD & LED indication for open, short, sounder fault, power supply fault, battery low etc. e. Fault buzzer mute facility f. Potential free contacts for both fire and fault g. Space for SMF batteries h. Connectivity with auto dialer (PSTN/GSM) as well with CMS i. Auxiliary relay contacts j. Walk test facility k. Compliance to IS 2189:1999 and approved by UL/LPCB/ERTL Certifications Required: UL/LPCB/ERTL. Make: Ravel. System Sensor, Jay, Bentel. Ionisation Smoke Detector(Conventional) a. Adjustable/programmable sensitivity b. Bi- colour LED light for status monitoring c. Operating voltage 8 to 33 VDC d. Flashing LED e. Magnetic test switch f. Addressable feature g. Response time 52 ms h. Sensitivity as per EN i. Low voltage operated Certifications Required: UL/LPCB approved Make: Apollo. System Sensor,. Optical Smoke Detector(Conventional) a. Adjustable/programmable sensitivity b. Bi- colour LED light for status monitoring c. Operating voltage 8 to 33 VDC d. Flashing LED e. Magnetic test switch f. Addressable feature g. Response time 52 ms h. Sensitivity as per EN i. Low voltage operated Certifications Required: UL/LPCB approved. Approve Make: Apollo. System Sensor,
Heat Detector (Conventional) a. Flashing LED b. Rate of rise cum fixed temperature c. Bi colour LED detector status indicator d. Programmable sensitivity through detector also e. Magnetic test switch f. Advance maintenance feature via remote hand held test unit g. UL/LPCB/EN approved h. Application temp. Range- -30 degree Celsius to +70 degree celcius Certifications Required: UL/LPCB approved Approve Make: Apollo. System Sensor,. Flame Detector (conventional) a. Using excellent UV sensor b. High sensitivity, reliable performance, dust proof, damp proofand corrosion proof c. Maximum response distance 25 m away from fire source d. Prolonged ambient temp. above 60 degree Celsius Certifications Required: UL/LPCB approved Make: Apollo. System Sensor, GST. Manual Call point(conventional) a. Anti- tamper facility b. Unique plug & play installation concept c. Backward compatibility d. Total flexi-ability in the choice of operating element e. Enhanced aesthetics f. Two part plug-in construction with base mounted termination allows easy installation and connection Certifications Required: ERTL Approved
SEMI ADDRESSABLE FIRE ALARM SYSTEM Fire Alarm Panel (Semi Addressable) a. 02, 04, 08 zone fire panel b. Digital display address of each device c. Maximum 32 device in each zone d. Minimum 50 event history with print facility e. Programmable through Keypad only f. Provision of separate Relay output for Fire and Panel fault g. Connectivity with auto dialer h. Compatible with all type & make of smoke detectors, heat detectors, flame detectors and manual call point i. Walk test j. Compatibility with CMS Certifications Required: UL/LPCB/ERTL. Make: Ravel. System Sensor, Jay, Bentel. Optical Smoke Detector(Semi Addressable) j. Adjustable/programmable sensitivity k. Bi- colour LED light for status monitoring l. Operating voltage 8 to 33 VDC m. Flashing LED n. Magnetic test switch o. Addressable feature p. Response time 52 ms q. Sensitivity as per EN r. Low voltage operated Certifications Required: UL/LPCB approved. Approve Make: Apollo. System Sensor,. Heat Detector (Semi Addressable) i. Flashing LED j. Rate of rise cum fixed temperature k. Bi colour LED detector status indicator l. Programmable sensitivity through detector also m. Magnetic test switch n. Advance maintenance feature via remote hand held test unit o. Application temp. Range- -30 degree Celsius to +70 degree celcius Approve Make: Apollo. System Sensor,.
Manual Call point (Semi Addressable) g. Anti- tamper facility h. Unique plug & play installation concept i. Backward compatibility j. Total flexi-ability in the choice of operating element k. Enhanced aesthetics l. Two part plug-in construction with base mounted termination allows easy installation and connection Make: Apollo. System Sensor. Hand Held Remote Device Tester a. To check optical detector physically b. To check the system health c. To reduce & increase the sensitivity of detector d. Operate from Minimum 10 feet distance Make: Apollo. System Sensor,. Fire Hooter (Semi addressable & Conventional) a. High sound output, low current consumption b. 02 tone sounder c. High Reliability and stable performance Make: Apollo. System Sensor,.
ADDRESSABLE FIRE ALARM SYSTEM Fire Alarm Panel (Addressable) a. Intelligent addressable panel of loop 1,2,3,..6 micro- processor expandable up to 300 loop based 02 wire fault tolerant loop for closed loop b. Each loop having maximum 99 detectors and 99 modules networking capacity c. Supervise & monitor all intelligent addressable detector and modules to the system for normal, trouble and alarm condition d. Compatible with Public addressable system e. All device manufactured supported f. Provision for signal silence switch, drill switch, system reset switch, lamp test, scroll display keys and print screen in panels g. Minimum 1000 history event with optional, local or remote print facility h. Minimum 20 zones with individual LED indicator. i. Panel programming facility both by computer and keypad j. Give location of all fire/fault conditions of addressable unit via the address code. k. Panel shall have rectifier, loop cards, minimum 80 character LCD unit to indicate fire/fault signal with address and analog output l. In built power supply and battery charger along with SMF batteries of 7 AH, 2x12 volt with 24 hour running back up. m. Minimum three 03 relay output for fire/fault/supervisory Addressable Smoke Detector (Addressable) a. Intelligent analog addressable inbuilt isolator photoelectric (light scattering) type with dual LED b. Hard addressable having rotary decade address switches from 01-99 or soft addressable facility through computer also c. Provision for bifurcation of dust and smoke for rejection of false fire alarm d. Adjustable sensitivity through Detector e. Bi- colour LED light for status monitoring f. Detectors ceiling mount and shall include a separate twist-lock base which includes a tamper proof feature g. In built short circuit isolator
Addressable Heat Detector (Addressable) a. Intelligent Analog addressable inbuilt isolator rate of rise/fixed heat detector complete with dual LED b. Hard Addressable with rotary decade switches from 01-99 or soft addressable facility through computer also c. 100% mechanical & electrical backwards compatibility d. In built short circuit isolator Laser Detector (Addressable) a. Intelligent analog addressable type high sensitivity laser based smoke detector having 9 sensitivity levels (from0.07-6.56%/m) complete with dual LED b. Hard addressable having rotary multi rotary decades switches from 01-99 or soft addressable facility through computer also c. 9 sensitivity levels(0.07-6.56%/m) d. Twin LEDs for 360 degree visibility Multi Sensor Detector (Addressable) a. Functional both through smoke and heat sensitivity b. Intelligent analog addressable inbuilt isolator multi criteria type detector with dual LED c. Hard addressable having rotary decade address switches or soft addressing facility through computer also d. Bi color LED light for status monitoring e. Adjustable sensitivity through detector also f. In built short circuit isolator Certifications Required: UL/LPCB approved. Beam Sensor Detector (Addressable) e. Intelligent analog addressable type high sensitivity laser based smoke detector having 9 sensitivity levels (from0.07-6.56%/m) complete with dual LED f. Hard addressable having rotary multi rotary decades switches from 01-99 or soft addressable facility through computer also g. 9 sensitivity levels(0.07-6.56%/m) h. Twin LEDs for 360 degree visibility
Certifications Required: UL/LPCB Manual Call point (Addressable) a. Unique plug & play installation concept b. In built short circuit isolator c. Integral loop isolation option d. Hard addressing facility and communicate with fire panels e. Backward compatibility f. Re-settable (non- breaking glass) via special key also g. Two part plug-in construction with base mounted termination allows easy installation and connection Certifications Required: UL/LPCB, Fire Hooter (Addressable) a. Storm and sounder facility b. Adjustable volume control by panel and device also. c. Simple familiar rotary wheel address control(hard integration) or soft integration by PC also d. Operate on 25 VRMS or with field selectable output taps from 0.5 to 2.0 watts e. Have at least 02 audibility options f. Low electric consumption Certifications Required: UL/LPCB Fire Repeater Panel (Addressable) a. Compatible with main fire alarm panel b. Back lit adjustable alphanumeric LCD displaying for all information like fire/fault etc. c. Local sounder mute and scroll alarm buttons d. Active or passive options e. Access Enable key- switch on active Certifications Required: UL/LPCB
Control Module (Addressable) a. Tri- colour Led status b. In built short circuit isolator c. Visible address selector switches or soft address through PC d. Minimum double output for control the device like fire damper, AHU tripping etc. e. In built additional provision of 24 VDC for power supply f. Compatible with IBMS of all platform g. Two part plug-in construction with base mounted termination for easy installation or surface mounting option Monitor Module (Addressable) a. Minimum two input for monitoring b. Tri colour LED status monitoring c. In built short circuit insulator d. Visible address selector switches or soft address through PC e. Status monitoring and compatible with IBMS of all platform f. Two part plug-in construction with base mounted termination for easy installation or surface mounting option g. In built additional provision of 24 VDC for power supply h. Provision for conventional item monitoring with address Response Indicator (Semi addressable, Conventional & Addressable) a. Single LED in red color b. Front cover marked FIRE c. Fabricated 16 SWG MS sheet d. Wide viewing angle e. Operating voltage 7 V DC to 26 V DC f. Suitable with all product g. Wide viewing angle ( at least 120 degree) Certifications Required: ERTL approved
Armored Cable (Semi addressable, Conventional & Addressable) a. 02 core 1.5 Sq.mm. armored cable with aluminum conductor b. Minimum 01 hr. fire retardant c. Armored & PVC schedules cables confirming to IS 1554 d. Fire Retardant Low toxic smoke (FRLS) cables e. Low HCL contents Certifications Required: ISI (IS 1554). Make: Polycab, R.R KABEL, Finolex. Battery (Semi addressable, conventional & Addressable) a. Sealed maintenance free b. Low self- discharge c. Eco- Friendly d. Excellent charge retention and recovering ability e. Minimum 20 hr back up at discharge 1.75V/cell f. Long service life g. Free from orientation constraints h. Approved by electric regulatory committee Make: EXIDE, AMARON GSM / PSTN Module (Semi Addressable & conventional) a. 03, 06, 09 input control facility b. Programmable I/O summary for software Connectivity with CMS c. Remote activation of outputs through caller recognition (zero charge) or by sending an SMS d. Can be installed inside panel cabinet ( no extra battery required) e. Can be used as a primary, backup or standalone communicator compatible with all control panels like security alarm, fire alarm & CCTV DVR Certifications Required: UL/LPCB approved Make: DSC, HONEYWELL, TEXECOM.