Method for Dual High Energy X-ray Imaging with Flat Panel Detectors

Similar documents
Appendix A. An Overview of Monte Carlo N-Particle Software

Atomic and Nuclear Physics Laboratory (Physics 4780)

90 degrees Bremsstrahlung Source Term Produced in Thick Targets by 50 MeV to 10 GeV Electrons

EDXRF of Used Automotive Catalytic Converters

Cargo Container X-ray Inspection Systems

ACCELERATORS AND MEDICAL PHYSICS 2

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

Chapter NP-5. Nuclear Physics. Nuclear Reactions TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 NUCLEAR REACTIONS 2.0 NEUTRON INTERACTIONS

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

2 Absorbing Solar Energy

ON-STREAM XRF ANALYSIS OF HEAVY METALS AT PPM CONCENTRATIONS

GAMMA-RAY SPECTRA REFERENCES

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

Production of X-rays and Interactions of X-rays with Matter

Spectroscopy. Biogeochemical Methods OCN 633. Rebecca Briggs

Introduction to the Monte Carlo method

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Tutorial 4.6 Gamma Spectrum Analysis

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

Introduction to Geiger Counters

Lecture 2 Macroscopic Interactions Neutron Interactions and Applications Spring 2010

Coating Thickness and Composition Analysis by Micro-EDXRF

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

CALCULATION METHODS OF X-RAY SPECTRA: A COMPARATIVE STUDY

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Diagnostic x-ray imaging relies on the attenuation of

A VERSATILE COUNTER FOR CONVERSION MÖSSBAUER SPECTROSCOPY

PHYA5/1. General Certificate of Education Advanced Level Examination June Unit 5 Nuclear and Thermal Physics Section A

Project 2B Building a Solar Cell (2): Solar Cell Performance

Radiation Detection and Measurement

Application Note # EDS-10 Advanced light element and low energy X-ray analysis of a TiB 2 TiC SiC ceramic material using EDS spectrum imaging

ENERGY LOSS OF ALPHA PARTICLES IN GASES

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

1. Orthovoltage vs. megavoltage x-rays. (AL) External beam radiation sources: Orthovoltage radiotherapy: kv range

ABSORPTION OF BETA AND GAMMA RADIATION

Gamma Rays OBJECT: READINGS: APPARATUS: BACKGROUND:

ALGORITHM TO DETERMINE THE CALIBRATION PARAMETERS FOR A NDA METHOD OF INVENTORY VERIFICATION IN A DIFFUSION ENRICHMENT CASCADE

Scanners more rapidly and accurately identify radioactive materials at US borders, events 22 June 2016, by Rob Matheson

Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center

1090 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 50, NO. 4, AUGUST Intelligent Gamma-Ray Spectroscopy Using 3-D Position-Sensitive Detectors

Page: 1 of 6 Page: 1 of 6

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

Lectures about XRF (X-Ray Fluorescence)

Medical Applications of radiation physics. Riccardo Faccini Universita di Roma La Sapienza

Clinical Photon Beams

Determination of the Effective Energy in X-rays Standard Beams, Mammography Level

Experimental study of beam hardening artefacts in photon counting breast computed tomography

X- and Gamma Ray Imaging Systems based on CdTe-CMOS Detector Technology

Cross section, Flux, Luminosity, Scattering Rates

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

Lab 4: Magnetic Force on Electrons

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

Variance reduction techniques used in BEAMnrc

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

Radiation Strip Thickness Measurement Systems

How To Understand Light And Color

Using Monte Carlo method for simulation of electromagnetic radiation penetration in body ' s tissues

Blackbody Radiation References INTRODUCTION

Clinical Physics. Dr/Aida Radwan Assistant Professor of Medical Physics Umm El-Qura University

Ultrasonic Wave Propagation Review

CHAPTER 7 SCINTILLATION COUNTING

Application Note: Absorbance

Lecture 14. Point Spread Function (PSF)

Jorge E. Fernández Laboratory of Montecuccolino (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli, 16, Bologna, Italy

Cone Beam Reconstruction Jiang Hsieh, Ph.D.

Lateral Resolution of EDX Analysis with Low Acceleration Voltage SEM

University of California at Santa Cruz Electrical Engineering Department EE-145L: Properties of Materials Laboratory

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Acquiring molecular interference functions of X-ray coherent scattering for breast tissues by combination of simulation and experimental methods

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

Calorimetry in particle physics experiments

Spectral distribution from end window X-ray tubes

The accurate calibration of all detectors is crucial for the subsequent data

ORTEC AN34 Experiment 7 High-Resolution Gamma-Ray Spectroscopy

Signal to Noise Instrumental Excel Assignment

Characteristics of an Integrated Germanium Detector Based Gamma-Ray Spectrometer for Monitoring Systems

Reflectance Measurements of Materials Used in the Solar Industry. Selecting the Appropriate Accessories for UV/Vis/NIR Measurements.

Quantitative Analysis Software for X-Ray Fluorescence. XRF-FP is a full-featured quantitative analysis package for XRF

Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission

Advanced Physics Laboratory. XRF X-Ray Fluorescence: Energy-Dispersive analysis (EDXRF)

Physics 441/2: Transmission Electron Microscope

Manual for simulation of EB processing. Software ModeRTL

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Tutorial on Using Excel Solver to Analyze Spin-Lattice Relaxation Time Data

Development of on line monitor detectors used for clinical routine in proton and ion therapy

Confocal μ-xrf for 3D analysis of elements distribution in hot environmental particles

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

Tuesday 20 May 2014 Morning

X-ray thin-film measurement techniques

Electron Microscopy 3. SEM. Image formation, detection, resolution, signal to noise ratio, interaction volume, contrasts

Performance of the Vidar Red LED Dosimetry Pro Advantage : A scanner optimized for use with GAFCHROMIC EBT Dosimetry Film.

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

Possibilities and Limits of Digital Industrial Radiology: - The new high contrast sensitivity technique - Examples and system theoretical analysis

Automation of a CT Acquisition: A System-based User-Support. 1. Introduction. Bärbel KRATZ 1, Frank HEROLD 1, Malte KURFISS 1

- thus, the total number of atoms per second that absorb a photon is

Recording the Instrument Response Function of a Multiphoton FLIM System

Advanced variance reduction techniques applied to Monte Carlo simulation of linacs

Transcription:

18th World Conference on Nondestructive Testing, 16-20 April 2012, Durban, South Africa Method for Dual High Energy X-ray Imaging with Flat Panel Detectors Markus FIRSCHING 1, Frank NACHTRAB 1, Theobald FUCHS 1, Norman UHLMANN 1 1 Fraunhofer IIS/EZRT Development Center X-Ray Technology, Dr.-Mack-Str. 81, 90762 Fürth, Germany Phone: +49 911 58061 7500, Fax: +49 911 58061 7599, email: markus.firsching@iis.fraunhofer.de Abstract Dual-energy X-ray imaging in the kev range is a well-known technique e.g. used in baggage scanning. It requires two measurements at different energies and/or detector efficiencies and allows displaying material properties as the effective atomic number and mass density. The method thus provides the information allowing identifying illicit materials such as explosives and contraband or high-z material used for shielding of radioactive or fissile material. Baggage scanners typically operate with 160 kvp X-ray sources, providing photons of energies between approximately 10 kev and 160 kev. For large objects as complete cars or sea freight containers for example, much higher photon energies are required to penetrate the object, i.e. in the range of a few MeV. The kev-dual-energy imaging exploits the energy dependence of the attenuation due to photoelectric and Compton effects. MeV-dual-energy imaging relies on pair production and Compton effect, which is more challenging since the energy dependence differs less between these effects. Due to the higher proportion of scattered radiation and the lower efficiency of flat panels, usually line detectors combined with a heavily collimated fan beam are used. However flat panel detectors offer a higher resolution and cover a twodimensional area which allows for shorter scan times. We employed a method using a ratio of the intensities in both images of different X-ray energies, and could show that materials differing in Z can be distinguished. We introduce the principles of the method and present first measurements from our 9 MV linear accelerator (LINAC) test facility. Keywords: dual energy, high energy, MeV, X-ray, imaging, Linac 1. Introduction Dual Energy X-ray imaging in the kev range is an established technique in both security and medical imaging. A well-known application is the non-intrusive scanning of the carry-on baggage at airports. It allows the identification of effective atomic numbers and densities of the materials under examination and thus can indicate high-z material used for shielding of radioactive or fissile material or other banned materials such as explosives and contraband. Baggage scanners typically operate with 160 kvp x-ray sources, providing photons of energies between approximately 10 kev and 160 kev. If an object as large as a sea freight container or a complete car needs to be scanned, much higher photon energies are required to penetrate the object, i.e. in the range of few MeV. The kev-dual-energy imaging exploits the energy dependence of the attenuation due to photo-electric and Compton Effect. MeV-dualenergy imaging relies on pair production and Compton Effect, which is more challenging since the energy dependence differs less between these effects. Due to higher proportion of scattered radiation and the lower efficiency of flat panels, usually line detectors combined with a heavily collimated fan beam have been used. While this is advantageous for very large objects, flat panel detectors allow faster 2D data acquisition for small and medium sized objects. As mentioned above, the kev-range dual energy techniques exploit the energy dependence of photo-electric effect and Compton scattering. While the change in cross section for Compton scattering is marginal over a wide range and the cross section for photo-electric absorption is decreasing approximately as the inverse cube of the Energy (E -3 ), i.e. it gets negligibly small at higher energies. However at energies above 1.022 MeV pair production can occur with an

increasing cross section at increasing photon energies. As the energy dependence of the attenuation due to pair production and Compton scattering is smaller than between photoelectric effect and Compton scattering, it is more challenging to apply a dual energy technique in the MeV range. The total mass attenuation coefficient is proportional to the sum of the cross section of all effects contributing to the attenuation process. Figure 1 shows a log-log plot of the total mass attenuation coefficient for carbon, iron and lead over the photon energy range from 10 kev to 10 MeV. With atomic numbers Z being 6, 26 and 82 respectively, these example materials cover the relevant range of atomic numbers very well. At lower energies, i.e. 25 kev for carbon, 120 kev for iron and 600 kev for lead, photoelectric absorption dominates. At medium energies, Compton scattering with its slowly decreasing cross section contributes most. At higher energies, i.e. 28 MeV for carbon, 10 MeV for iron and 5 MeV for lead, pair production in the nuclear field eventually becomes the dominating factor of the attenuation. Figure 1 also shows that the attenuation coefficient differs very little for light materials (in this case carbon and iron) for energies between 300 kev and 3 MeV and therefore and this part cannot contribute to the dual energy method. Unfortunately this energy range accounts for a large part of the spectrum of a typical MeV Linac source spectrum. Figure 1. Mass attenuation coefficient for selected materials between 10 kev and 10 MeV 2. Methods The signal of a detector working in energy integrating regime is exp μ where I(E) is the incident X-ray spectrum, D(E) the detector efficiency, µ i (E) the mass attenuation coefficient of material i, and d i the thickness of the respective material. The distinction between different materials is based on the differences of the attenuation

coefficients. But, as the above equation shows, the attenuation coefficient is not accessible directly. To retrieve information on the type of material a combination of two measurements of the object with different incident source spectra and/or detector efficiencies needs to be done. These two imaging situations will be called low and high energy (LE and HE). The ratio of the logarithmized HE and LE (Q-values) plotted images over the intensity of the unchanged intensity yields a characteristic line for each material: log log For a given detector efficiency and source spectra, this value can be calculated for materials with known attenuation coefficient. The so called Q-plots (see Fig. 2) are element specific; at least for an interval of atomic numbers, i.e. multiple groups of elements can be distinguished. Its performance is strongly impacted by the filtering of the incident spectra. Figure 2. Q-plot for a selection of materials for areal densities from 1 to 200 g/cm 2 in steps of 1 g/cm 2. The right end of the curve corresponds to 1 g/cm 2 the left end to 200 g/cm 2 Using such a set of curves, every pixel can be associated not only with an intensity value (brightness) but also a type of material (effective atomic number). In the example of Figure 2 the Q-values are calculated for a pencil beam geometry neglecting the scattered radiation. The low and mid-z materials can be separated, while tungsten and lead show very similar Q- values for most areal densities. 3. First measurements and preliminary results The first measurements were done using a linear accelerator (Linac) with tungsten target and voltages up to 9 MV as an x-ray source. The detector is a flat panel Perkin Elmer XRD 1640 AL1 with 0.4 mm pixel pitch. Figure 3 shows an image of a lead step wedge with thicknesses

from 14.4 mm to 5.4 mm in steps of 1.8 mm (from left to right) using a 5 MV; the second energy for the dual energy measurement was 9 MV. Furthermore an Aluminum step wedge with thicknesses from 40 mm to 100 mm in steps of 20 mm was used. The resulting Q-plot for the aluminum and lead step wedges can be seen in Figure 4. Figure 3 Image of a lead step wedge imaged with the flat panel detector using a 5 MV spectrum from the Linac. Figure 4. Q-plot of the aluminium and lead step wedge measurement imaged with the flat panel detector at 5 and 9 MeV.

Figure 4 shows that these two materials can be separated clearly over the considered thicknesses/intensities. We expect at least four Z-intervals (intervals of atomic numbers) to be distinguishable. 4. Conclusion We introduced a method for dual energy imaging in the MeV range. Despite expected problems due to the low efficiency of the flat panel detector and large amounts of scattered radiation due to cone beam acquisition geometry, first results indicate the method is still applicable. Flat panel detectors have very high (sub-millimeter) resolution compared to line detectors typically used in high energy X-ray imaging (approximately 5 mm). 2-D data acquisition allows faster scans, as it utilizes a larger part of the radiation field of the source. Assignment of colors corresponding to atomic number as in kev-dual energy is also feasible to generate colorized images to help the inspecting personnel to identify defined materials. Based on these features of flat panel detectors and dual energy capabilities, new areas of deployment arise.