INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

Diesel Engine Driven Generators Page 1 of 6

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

Annex-A TECHNICAL SPECIFICATION

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Magnum Mobile Generator MMG55 Specifications

Medical Air Systems: Scroll

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1

Gas Turbine Power COMPACT, EFFICIENT, RELIABLE

Fire Pump Plan Review March 2010

ECOCIAT. Domestic hot water heat recovery unit

Rotary screw compressors kw 5,5 7, , bar MODULO

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

Competency Framework for Marine Engineer Class 6. Competency Framework for Marine Engineer Class 6

AIR CONDITIONING SYSTEM 1. FFH SPECIFICATION AIR CONDITIONING SYSTEM RODIUS

Evaluate, Clean, and Tune Guidance

Marine Generating Sets 3.7 to 50 kva

Oil and Coolant Circulating Heating System. Model - OCSM

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

Technical Specification. Generating Set with Waukesha engine burning natural gas

Commercial Gas Furnace Upflow

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

BIOPOWER 5 CEX. 1 Wärtsilä 10 January 2012 Presentation name / Author

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

Factory owners must ensure the boiler is:

Titan Makina Ltd. Şti Sok. No: 9 Ostim Ankara Tel: Fax: Web:

Energy Savings through Electric-assist Turbocharger for Marine Diesel Engines

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

CENTAUR 40 Gas Turbine Generator Set

Emergency Response Guide

Cooking at the Speed of light!

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

COMMISSIONING OF HVAC SYSTEMS

Element D Services Plumbing

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

REMOVAL AND INSTALLATION

Maintaining Fire Protection Systems

4000 Series 4008TAG2A Diesel Engine ElectropaK rpm

USER S MANUAL HSC-24A

POWER PLANT GAS CONVERSIONS WÄRTSILÄ SPARK IGNITED GAS ENGINE (SG) CONCEPT

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

Trouble Shooting. Pump

Prime Power Services, Inc. Georgia, Carolinas NFPA 110 Standards for Emergency & Stand by Generators June 1, 2010

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Kobelco Extended Warranty Program.

Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

D Youville College July 31, 2008 New Academic Building Cannon Design Project No

National Competency Based Skill Training Refrigeration and Air-conditioning Mechanic Logbook

DIESEL GENERATOR SETS

ANCILLARY EQUIPMENT AND ELECTRICAL EQUIPMENT Power Supply Systems and Electrical Equipment for Desalination Plants - Y.M. Hamud and A.H.

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

SECTION FIRE AND SMOKE ALARM SYSTEM. City of San Diego, CWP Guidelines

C18 ACERT Fire Pump Tier bkw/ rpm

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

WHOLESALE DIRECT INC WEST 65TH STREET

vacon ac drives for mining & minerals

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

WINDOW ROOM AIR CONDITIONER

REMOTE MONITORING AND CONTROL OF THE KAKKONDA GEOTHERMAL POWER PLANTS

Diagnostic Fault Codes For Cummins Engines

In addition, a number of auxiliary options are available (para 2.7) as well as optional slices for special requirements (para 2.8).

FAIRBANKS NIJHUIS FIRE PUMPS.

Conventional Fire Detection and Extinguishant Control System Specification

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

RESIDENTIAL HEATING OIL SERVICE CONTRACT ANNUAL COST $276.00

Note: This information obtained from internet sources and not verified- use at your own risk!!!!

OASIS SERVICE & TROUBLESHOOTING MANUAL (WITH DM10 OR DM12)

Important Ontario Fire Code Information for Building Owners in the City of Windsor

Bulk Storage the OIL SAFE Way. Three System Types. Establish Best Practice

Element D Services Plumbing

Transformer oil cooler ALFA A02

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

Your safety and the safety of others are very important.

FOXAIR 60/50 ALL MODELS

Top Technology for Industry, Agriculture, Business and Communities


Recommended Practice for Installation of Transit Vehicle Fire Protection Systems

Installation and maintenance instructions. Danfoss Vent

Diesel Generating Set

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

Model 1210C Battery Powered Pump Shown. Description

SECTION MORTUARY REFRIGERATORS

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT kva / ekw

RPV - RP - RA air handling units

HVAC Processes. Lecture 7

Fossil fuel heating equipment

Frequently Asked Questions. Air Top Diesel Heaters. 2000STC, Evo 40 & Evo 55

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

Signature and ISX CM870 Electronics

1/11 CO2 DOSAGE SYSTEMS. CO2 dosage system consists of following parts;

Transcription:

D & S Turbine International LLC 281-333-5652 MOBILE POWER GENERATION EQUIPMENT Nomad 5 3.8 MW / 4875 KVA 50Hz 11KV Mobile Power Station

MOBILE POWER GENERATION EQUIPMENT Nomad 5 3.8 MW / 4875 KVA 50Hz 11KV Mobile Power Station PURCHASE OPTIONS The equipment is currently undergoing refurbishment. Based entirely on the purchaser s needs, location and regulatory compliance, it will be possible to choose between several refurbishment options. EQUIPMENT OVERVIEW The Nomad 5 is a complete, single-trailer power package, capable of generating up to 3.8MW ISO. It can easily and quickly be moved on a standard flatbed truck unit, transferring from one location to another as changing circumstances dictate and made operational less than 48 hours after arrival on site. Proven Reliability Liquid Fuel (Dual Fuel Capability, as an option) Black Station Start Capability Generator 3.8 MW, 4875 KVA 50HZ, 11KV Robust Design Operational in Extreme Climatic Conditions Acoustic Treatment

A B C D E POWER STATION TRAILER EQUIPMENT PLAN COMPRISING On Board Control Room A The air-conditioned control room houses the generator control and protection system, auxiliary and control batteries, system battery charger, motor control center and a selectable 400 VAC distribution board. The distribution board inputs provide the facility for external customer supply, on board diesel generator supply for Power Station Black Start Capability and auto transfer to auxiliary transformer supply derived from the trailer alternator once the turbine driver is running. Alternator Compartment D In this compartment is the GEC-Unipac alternator rated at 4875KVA and auxiliary transformer 11KV to 415VAC for trailer internal power distribution. Cooler and Switchgear Compartment E The 11KV generator circuit breaker, the HV terminal chamber for connection to the customer s load, the turbine lubrication system air blast cooler and firefighting equipment are housed in this compartment. Diesel Compartment B A 500 liter diesel fuel tank is integrated to the trailer chassis, housing a turbo charged diesel engine. Thus providing starting capability for the turbine and auxiliary power generation to provide power to the trailer 400VAC distribution board. Turbine Compartment C This compartment houses a TB5000 model gas turbine prime mover, turbine fuel and fluid systems, control devices, instrumentation, turbine lubrication oil tank and Allen type speed reduction gearbox.

TECHNICAL AND PERFORMANCE FEATURES OF THE NOMAD 5 MOBILE POWER STATION STANDARD NOMAD 5 CONFIGURATION Turbine Engine Core Model TB5000 (5000 BHP ISO Base Load rating on gas fuel), twin shaft, heavy duty industrial gas turbine complete with: Air inlet casing phased upwards air inlet flexible joint Gas generator assembly Combustor assembly incorporating 4 combustion chambers Power turbine assembly Exhaust outlet casing phased vertically upwards Exhaust outlet flexible joint Under Base Turbine underbase of fabricated carbon steel construction, designed for four-point mounting on full automatic hydraulic installation support jacks Hydraulic jacks designed for quick installation and easy moving of unit without crane work Mobile Unit can be placed on an uneven surface due to the adjustable hydraulic support jacks Turbine mounting, allowing thermal expansion Retractable lifting tubes to facilitate heavy lift handling Lubricating oil and auxiliary diesel fuel tanks integral to underbase Acoustic Enclosure Fitted over the turbine, gearbox and alternator and bolted to the turbine under base. Reduce package noise to an acceptable level. Enclosure incorporating: Internal lighting steel construction Access doors for personnel maintenance access Removable panels for maintenance access Acoustic enclosure ventilation inlet damper Acoustic enclosure ventilation outlet damper Acoustic enclosure ventilation air flow detector Acoustic enclosure ventilation system Ventilation Filter High efficiency cleanable pad type combustion air filter Ventilation Fan AC electric motor-driven ventilation outlet fan to Zone 1 classification, duct-mounted (Ex d type) Combustion Air Inlet System Standard 2 stage combustion air inlet filter with particle extraction louver integral to trailer housing Combustion Exhaust System Exhaust diffuser with flexible joint and transition ducting to enclosure roof. (Exhaust stack as an option) Lubricating Oil System Integral lubricating oil system, including all pipe work, serving the gas turbine, gearbox and driven unit Lubricating oil tank integral to trailer underbase Lube oil pressure and temperature transmitters Main pump, gearbox-driven Auxiliary pump, AC electric motor driven (pre start and post shutdown lubrication) Emergency pump, DC electric motor driven (emergency cooling) Lubricating oil supply piping in stainless steel downstream of filters Duplex filters with manual changeover valve; differential pressure gauge and differential pressure transmitter Lubricating oil pressure gauge and transmitter oil tank temperature transmitter Oil tank level gauge Oil tank low oil level transmitter Lubricating Oil Cooler Air blast simplex vertical matrix lubricating oil cooler, suitable for high ambient temperature range

Standard Nomad 5 Configuration Lubricating Oil Breather Breather system internal to Acoustic Enclosure (including a carbon steel Sand Trap) Lube oil breather piping external vent Stainless steel flame trap for mounting in the external breather piping Starting System Diesel engine driven hydraulic start system Ignition System High tension igniters (4) Fully piped ignition system utilizing propane gas fuel supply Gearbox and Coupling Direct coupled Epicyclic type gearbox manufactured by Allen Gears giving an output shaft speed of 1,500 RPM. Low maintenance output coupling between gearbox and AC generator. Gas Fuel System Only Gas fuel piping in stainless steel Gas fuel pressure gauges for fuel valve and burners Gas fuel pressure relief valve Gas fuel pressure transmitter Gas fuel shutoff valve, emergency, rapid acting Gas fuel shutoff valve, manually operated Gas Fuel Valve Liquid Fuel System Only Liquid fuel piping in stainless steel On trailer Duplex fuel filter permitting on line duty filter replacement AC motor driven liquid fuel boost pump, gearbox driven main fuel pump Governor-actuated fuel valve Solenoid-operated fuel shut-off valve Manual emergency shut-off valve Burner pressure gauge Gas ignition system Combustion chamber auto-drain valves Fire Protection and Gas Detection System The old firefighting system is upgraded by installing a new high quality fire fighting system, incorporating: DBI approved control panel. Detection, operation and surveillance are operated by the control panel The system is provided with emergency power for 30min operation, and change automatically to emergency power when power failure appears. 2 Ultra-violet flame detectors in the turbine section 2 Heat detectors in the engine starter section 2 Heat detectors in the generator section 2 Smoke detector in the control room 3 Gas detectors Energen fire protection system, approved for use in crew area Automatic extinguisher release and visible alarms Turbine Compressor Cleaning System Cold turbine compressor wash system Mobile wash trolley, incorporating cleaning fluid/rinse tank fitted with integral pressure relief valve, air pressure control solenoid valve, air/ wash fluid flexible hose with quick release connections, and electrical cable Drain system incorporating automatic drain valve Pressure transmitter to monitor intermediate stage blow-off valves closing air pressure AC Generator Brushless AC generator, voltage 11kv and frequency to 50Hz, to sound attenuation of 85dba Generator cooling type CACA Generator bearing temperature detectors Class F insulation / F total temperatures AC generator lube oil system provided by the gas turbine Underbase of fabricated steel construction Generator alignment jacking screws. The generator is suitable for a non-hazardous area.

STANDARD NOMAD 5 CONFIGURATION HV Generator Circuit Breaker New Schneider Electric 630A 11KV Generator breaker and outgoing feeder Generator Control Panel New Automatic voltage regulator New Generator metering equipment New Generator electrical protection relays New Automatic and manual synchronizing facility with check synch Emergency Stop push-buttons externally mounted on turbine under base Local stop push-buttons on turbine AC motors Motor Control Centre New Motor control center for supply to AC and DC motors and solenoids Electrical Equipment New On-package AC and DC interface cabling Integral earth protection bonding

Standard Nomad 5 Configuration UPS System/Batteries New UPS is running online with double conversion technology with the following operation: AC input is filtered and then converted into DC that is used to recharge the batteries. Should a power failure occur on the AC system, the UPS design maintains emergency DC-power to the DC-controller that controls the turbine DC supply New Batteries 150 AH and 120 AH. Maintenance free batteries are mounted within a carbon steel battery storage cabinet located externally adjacent to control room English language on front panels 17 monitor, SCADA system Remote control and troubleshooting via VPN router (Requires Acces to internet) Warranty The Contractor shall be liable for defects in the goods in accordance with the contract conditions for a period of 12 months from first use. Instrumentation Air inlet temperature thermocouples Exhaust outlet and power turbine exit temperature thermocouples Gas generator speed probe Power turbine speed probe Mechanical overspeed protection trip Casing mounted seismic sensor to turbine, gearbox and driven unit Control system/sequencer New PLC system of Siemens or Alan Bradley origin with local I/O chassis PLC Controller for sequencing and turbine control and supervision Overspeed protection unit Emergency stop relay Industrial Ethernet switch Watchdog relay Hours run indicator Fired starts counter Operator control panel Fault Monitoring Temperature Monitoring Turbine Casing Vibration Monitoring Turbine Gearbox Casing Vibration Monitoring Driven Unit Vibration Monitoring Driven Unit Bearing Temperature Monitoring Control for standard Gas Detection Monitor

OPTIONS Turbine Engine Core Model TB5400, twin shaft heavy duty industrial gas turbine. This is the latest TB engine variant with air cooled first stage turbine, upgraded 5400 BHP power unit. Starting System An upgraded system with AC-start replaces the old hydraulic starting system. The upgraded system comes with a suitably sized AC generator driven by a Perkins diesel engine. Upgraded starter system, incorporating: Standard 2/4 pole electric starter motor Revised drive coupling Starter gear box arrangement AC starting is a simple and reliable start system Generator data: Olympian model LL3014H, 165 KVA, 132 KW Engine data: Perkins model - 1106C-E66TAG3, 6cyl 3 Phase, 400V AC, 50HZ Dual Fuel Capability The engine can be fitted with duplex fuel system so that either gas or liquid fuel may be used. Capability: The changeover from one fuel to the other is automatic during operation and is initiated by pressing the appropriate push button Provision is also made for when the engine is running on gas, for an automatic changeover to liquid fuel if the supply gas pressure falls below a site determined figure Ventilation silencing For average sound attenuation to 85dB (A) SPL at 1m distance measured at 1.2m above ground level. Special made enclosure incorporating: Ventilation for oil cooler, intake and blowers Generator ventilation, intake and blowers Enclosure ventilation, intake and blowers Diesel engine, intake and blower

OPTIONS Acoustic Enclosure Fitted over the turbine, gearbox and alternator and bolted to the turbine underbase, for average sound attenuation to 85dB (A) SPL at 1m distance measured at 1.2m above ground level. Special made enclosure, incorporating: The enclosure has been enlarged from 2.40m to 3.50m wide Extra silencing of the enclosure makes it easy to get authority approval in western countries Comfortable and easy servicing, also in bad weather conditions, due to the enlarged enclosure Removable sections for maintenance access Access doors provide for personnel maintenance access Internal lighting steel construction Acoustic enclosure ventilation inlet damper Acoustic enclosure ventilation outlet damper Acoustic enclosure ventilation air flow detector Acoustic enclosure ventilation system Note: The enclosure is specially made and can be made to order on the basis of the customers request. Combustion Air Inlet System Multi-stage offskid 20 container combustion air inlet filter, for average sound attenuation to 85dB (A) SPL at 1m distance measured at 1.2m above ground level. Special made combustion air inlet filter system incorporating: Sand filter made of corrosion-resistant material Turbine filter elements, type F7 with pre-filter type CAM GT, EN 779 Multi-stage silencer Inspection manhole for filter change Compensator and steel spacer from turbine to 20 container Extra silencing of the combustion air inlet filter system makes it easy to get authority approval in western countries Easy to relocate and a quick set up solution. Note: The Inlet container is specially made and can be made to order on the basis of the customers request.

OPTIONS Combustion Exhaust System Exhaust system is built on a 40 offskid container with exhaust ducting stack to elevation of approximately 4m above ground level, for average sound attenuation to 85dB (A) SPL at 1m distance measured at 1.2m above ground level. Special made exhaust system incorporating: Silencer for an overall 85dB (A) rating Silencer mounting allowing for thermal expansion Compensator and steel spacer from turbine to 40 container Two-piece exhaust stack for easy transport Easy to relocate and a quick set up solution Extra silencing of the exhaust system makes it easy to get authority approval in western countries Exhaust diffuser mounted sideways with flexible joint and transition ducting to enclosure side Prepared for installation with permanent exhaust ducting stack. (foundation necessary) Note: The Exhaust system is special made and can be made to order on the basis of the customers request. For compliance with local grid code: Grid Code Compliance UCTE/ENTSO-E Block diagrams and dynamic system documentation according to IEEE Specification

D & S Turbine International LLC 281-333-5652 Houston, Texas HKJ Gas Turbine Services A/S Haandvaerkervej 19, DK-6710 Esbjerg V, Telephone: (+45) 7546 8030, Fax: (+45) 7546 8077