CENTAUR 40 Gas Turbine Generator Set

Size: px
Start display at page:

Download "CENTAUR 40 Gas Turbine Generator Set"

Transcription

1 CENTAUR 40 Industrial/Utility Grade Features Industrial Gas Turbine Package Compact, Integrated Package Providing Ease of Installation Factory Tested Dry, Low Emission (SoLoNOx ) Combustion Available Onskid Microprocessor-Control with Auto Sync Capability Multiple Fuel Capability Package Arrangement Gas Turbine Centaur 40 Industrial, Single-Shaft Axial Compressor 11 Stages Annular Combustion Chamber 10 Fuel Injectors Coatings Compressor: Inorganic Aluminum Turbine and Nozzle Blades: Precious Metal Diffusion Aluminide Proximity Probe Vibration Transducers Main Reduction Drive Epicyclic 1800 or 1500 rpm Acceleration Vibration Transducers Generator Salient Pole, 3 Phase, 6 Wire, Wye Connected, Synchronous with Brushless Exciter Open Drip-Proof Construction Sleeve Bearings Velocity Vibration Transducers Solid-State Voltage Regulation with Permanent Magnet Generator NEMA Class F Insulation with F Rise Continuous Duty Rating Package Steel Base Frame with Drip Pans Direct-Drive AC Start System Natural Gas Fuel System Microprocessor-Based PLC Generator Control Vibration and Temperature Monitoring Auto Synchronizing Integrated Lube Oil System Turbine-Driven Lube Pump AC Pre/Post Lube Pump Backup Lube Pump Air/Oil Cooler Integral Lube Oil Tank Lube Oil Tank Heater Lube Oil Filter Documentation Drawings Quality Control Data Book Inspection and Test Plan Test Reports O&M Manuals Factory Testing of Turbine and Package Optional Equipment/Services Generator Options: WPII, TEWAC Standby Duty Rating Standard Voltages: 3300, 6600, 11, Hz; 4160, 6900, 12,470, 13, Hz Fuel Systems Liquid Dual (Gas/Liquid) SoLoNOx, Dry, Low Emission Alternate Fuels (such as naphtha, propane, low Btu) Lube Oil System Water/Oil Lube Cooler Electrostatic Demister Duplex Lube Oil Filters Remote Display/Control Terminal Heat Recovery Application Interface Serial Link Supervisory Interface KW Control KVAR/Power Factor Control Turbine Performance Map Historical Displays Printer/Logger Predictive Emissions Monitoring Field Programming Terminal Accessory Equipment 24-VDC Battery/Charger System Turbine Cleaning System: On-Crank and On-line Package Lifting Kit Weatherproof Acoustic Enclosure Ancillary Equipment: Various Air Inlet and Exhaust Systems Inlet and Exhaust Silencers Self-Cleaning or Prefilter/Barrier Air Inlet Filter Inlet Evaporative Cooler Inlet Chiller Coils Ancillary Support Frame

2 CENTAUR 40 Nominal Performance* Available Performance Output Power, kwe ISO: 15 C (59 F), sea level 3515 Heat Rate, kj/kwe-hr (Btu/kWe-hr) (12,240) Exhaust Flow, kg/hr (lb/hr) (147,718) Exhaust Temperature, C 437 ( F) (819) * No inlet or exhaust losses Relative humidity 60% Natural gas fuel with LHV = 31.5 to 43.3 MJ/nm 3 (800 to 1100 Btu/scf) OUTPUT POWER AT GENERATOR TERMINAL, MWe (61) Full Load Output 14 (48) 16 (55) 12 (41) Fuel Flow, MW (MM Btu/hr) 10 (34) 8 (27) 250 (482) 300 (572) Exhaust Temperature, C ( F) Exhaust Flow, Thousands kg/hr (lb/hr) 400 (752) 350 (662) 500 (932) 450 (842) (168) -30 (-22) 74 (163) 72 (159) -10 (14) 70 (154) 68 (150) 10 (50) 66 (146) 64 (141) 62 (137) 30 (86) 50 (122) INLET AIR TEMPERATURE, C ( F) DS40IPG-002M Typical Service Connections Forward End Turbine Control Box Length: 9754 mm (32 0 ) Width: 2438 mm (8 0 ) Height: 2591 mm (8 6 ) Approx. Weight: Forward End kg (57,350 lb) Left Side Lube Oil: Drain, Vent, Cooler Generator Control Box, Power Generator Drip Pan Drain AC Power Lube Tank Heater Pre/Post Lube Pump Backup Lube Pump Right Side Left Side AC Power - Start Motor Generator Monitor Box Aft End Aft End DS40IPG-003M Fuel Inlet Turbine Cleaning Fuel Filter, Combustor and Exhaust Collector Drains Auxiliary Air (optional) for: Liquid Fuel Atomizing Self-Cleaning Filter AC Power Liquid Fuel Pump (optional) Package Ground Solar Turbines Incorporated P.O. Box San Diego, CA Caterpillar is a trademark of Caterpillar Inc. Solar, Centaur and SoLoNOx are trademarks of Solar Turbines Incorporated. Specifications subject to change without notice. Printed in U.S.A Solar Turbines Incorporated. All rights reserved. DS40IPG/1198/5M FOR MORE INFORMATION Telephone: (+1) Telefax: (+1) Telex: Internet:

3 CENTAUR 50 Industrial/Utility Grade Features Industrial Gas Turbine Package Compact, Integrated Package Providing Ease of Installation Factory Tested Dry, Low Emission (SoLoNOx ) Combustion Available Onskid Microprocessor-Control with Auto Sync Capability Multiple Fuel Capability Package Arrangement Gas Turbine Centaur 50 Industrial, Single-Shaft Axial Compressor 11 Stages Annular Combustion Chamber 12 Fuel Injectors Coatings Compressor: Inorganic Aluminum Turbine and Nozzle Blades: Precious Metal Diffusion Aluminide Proximity Probe Vibration Transducers Main Reduction Drive Epicyclic 1800 or 1500 rpm Acceleration Vibration Transducers Generator Salient Pole, 3 Phase, 6 Wire, Wye Connected, Synchronous with Brushless Exciter Open Drip-Proof Construction Sleeve Bearings Velocity Vibration Transducers Solid-State Voltage Regulation with Permanent Magnet Generator NEMA Class F Insulation with F Rise Continuous Duty Rating Package Steel Base Frame with Drip Pans Direct-Drive AC Start System Natural Gas Fuel System Microprocessor-Based PLC Generator Control Vibration and Temperature Monitoring Auto Synchronizing Integrated Lube Oil System Turbine-Driven Lube Pump AC Pre/Post Lube Pump Backup Lube Pump Air/Oil Cooler Integral Lube Oil Tank Lube Oil Tank Heater Lube Oil Filter Documentation Drawings Quality Control Data Book Inspection and Test Plan Test Reports O&M Manuals Factory Testing of Turbine and Package Optional Equipment/Services Generator Options: WPII, TEWAC Standby Duty Rating Standard Voltages: 3300, 6600, 11, Hz; 4160, 6900, 12,470, 13, Hz Fuel Systems Liquid Dual (Gas/Liquid) SoLoNOx, Dry, Low Emission Alternate Fuels (such as naphtha, propane, low Btu) Lube Oil System Water/Oil Lube Cooler Electrostatic Demister Duplex Lube Oil Filters Remote Display/Control Terminal Heat Recovery Application Interface Serial Link Supervisory Interface KW Control KVAR/Power Factor Control Turbine Performance Map Historical Displays Printer/Logger Predictive Emissions Monitoring Field Programming Terminal Accessory Equipment 24-VDC Battery/Charger System Turbine Cleaning System: On-Crank and On-line Package Lifting Kit Weatherproof Acoustic Enclosure Ancillary Equipment: Various Air Inlet and Exhaust Systems Inlet and Exhaust Silencers Self-Cleaning or Prefilter/Barrier Air Inlet Filter Inlet Evaporative Cooler Inlet Chiller Coils Ancillary Support Frame

4 CENTAUR 50 Nominal Performance* Output Power, kwe ISO: 15 C (59 F), sea level 4600 Heat Rate, kj/kwe-hr (Btu/kWe-hr) (11,628) Exhaust Flow, kg/hr (lb/hr) (151,410) Exhaust Temperature, C 509 ( F) (949) * No inlet or exhaust losses Relative humidity 60% Natural gas fuel with LHV = 31.5 to 43.3 MJ/nm 3 (800 to 1100 Btu/scf) Available Performance OUTPUT POWER AT GENERATOR TERMINAL, MWE (172) 20 (68) 18 (61) 250 (482) 200 (392) 450 (842) 400 (752) 350 (662) 300 (572) Full Load Output 16 (55) 14 (48) 12 (41) 10 (34) 8 (27) 550 (1022) Fuel Flow, MW (MM Btu/hr) Exhaust Temperature, C ( F) 74 (163) 70 (154) 66 (146) 62 (137) 500 (932) -40 (-40) -20 (-4) 0 (32) 20 (68) 40 (104) 58 (129) Exhaust Flow, Thousands kg/hr (lb/hr) INLET AIR TEMPERATURE, C ( F) DS50IPG-002M Typical Service Connections Forward End Turbine Control Box Length: 9754 mm (32 0 ) Width: 2438 mm (8 0 ) Height: 2591 mm (8 6 ) Approx. Weight: Forward End kg (60,470 lb) Left Side Lube Oil: Drain, Vent, Cooler Generator Control Box, Power Generator Drip Pan Drain AC Power Lube Tank Heater Pre/Post Lube Pump Backup Lube Pump Right Side Left Side AC Power - Start Motor Generator Monitor Box Aft End Aft End DS50IPG-003M Fuel Inlet Turbine Cleaning Fuel Filter, Combustor and Exhaust Collector Drains Auxiliary Air (optional) for: Liquid Fuel Atomizing Self-Cleaning Filter AC Power Liquid Fuel Pump (optional) Package Ground Solar Turbines Incorporated P.O. Box San Diego, CA Caterpillar is a trademark of Caterpillar Inc. Solar, Centaur and SoLoNOx are trademarks of Solar Turbines Incorporated. Specifications subject to change without notice. Printed in U.S.A Solar Turbines Incorporated. All rights reserved. DS50IPG/1198/5M FOR MORE INFORMATION Telephone: (+1) Telefax: (+1) Telex: Internet:

5 MARS 100 Gas Turbine Compressor Set General Specifications Mars 100 Gas Turbine Industrial, Two-Shaft Axial Compressor 15-Stage Variable Inlet Guide Vanes Compression Ratio: 17.4:1 Inlet Airflow: 41.3 kg/sec (91.0 lb/sec) Max. Speed: 11,168 rpm Vertically Split Case Combustion Chamber Annular-Type Conventional or Lean-Premixed, Dry, Low Emission (SoLoNO x ) 21 Fuel Injectors (Conventional) 14 Fuel Injectors (SoLoNO x ) Torch Ignitor System Gas Producer Turbine 2-Stage, Reaction Max. Speed: 11,168 rpm Power Turbine 2-Stage, Reaction Max. Speed: 9500 rpm Bearings Journal: Tilting-Pad Thrust, Active: Tilting-Pad Thrust, Inactive: Fixed Tapered Land Coatings Compressor Stators and Drum: Inorganic Aluminum Turbine and Nozzle Blades: Precious Metal Diffusion Aluminide Vibration Transducer Type Proximity Probes Key Package Features Driver Skid with Drip Pans Driven Equipment Skid Compressor Compressor Auxiliary Systems 316L Stainless Steel Piping <4" Compression-Type Tube Fittings Gauge Panel Options Fluid Gauges Digital Display Electrical System Options NEC, Class I, Group D, Div 1 or 2 CENELEC, Zone 1 Turbotronic Microprocessor Control System Freestanding Control Console Color Video Display Vibration Monitoring Control Options 24-VDC Control Battery/ Charger System 120-VDC Accessory Battery/ Charger System Gas Turbine and Package Temperature Monitoring Serial Link Supervisory Interface Turbine Performance Map Compressor Performance Map Historical Displays Printer/Logger Predictive Emissions Monitoring Process Controls Compressor Anti-Surge Control Field Programming Start Systems Pneumatic Direct Drive AC Fuel Systems Natural Gas Dual (Gas/Liquid) Integrated Lube Oil System Turbine-Driven Accessories AC Motor-Driven Accessories Oil System Options Oil Cooler Oil Heater Tank Vent Separator Flame Trap Axial Compressor Cleaning Systems On-Crank On-Crank/On-Line Portable Cleaning Tank Gearbox (if applicable) Speed Increaser Speed Decreaser Air Inlet and Exhaust System Options Enclosure and Associated Options Factory Testing of Turbine and Package Documentation Drawings Quality Control Data Book Inspection and Test Plan Test Reports Operation and Maintenance Manuals

6 MARS 100 Gas Turbine Compressor Set Performance No Inlet/Exhaust Losses, Relative Humidity 60%, Natural Gas Fuel with LHV = 31.5 to 43.3 MJ/nm 3 (800 to 1100 Btu/scf) Optimum Power Turbine Speed AC-Driven Accessories Engine Efficiency: 34.0% Nominal Rating ISO At 15 C (59 F), Sea Level Output Power kw (15,000 hp) Heat Rate kj/kw-hr (7490 Btu/hp-hr) Exhaust Flow kg/hr (331,500 lb/hr) Exhaust Temp 486 C (906 F) 15 C (59 F) Turbine Rating Match. Other Turbine Rating Match Points Are Available. Available Power OUTPUT POWER PARAMETER, kw (hp) (20,115) (17,433) (14,751) 9000 (12,069) 7000 (9387) 5000 (6705) 170 (375) 160 (353) Full Load Output 150 (331) 140 (309) 40 (136) 325 (617) 130 (287) 120 (265) 110 (243) 425 (797) 35 (119) 475 (887) Fuel Flow, MW (MM Btu/hr) 375 (707) 525 (977) 30 (102) Exhaust Temperature, C ( F) Exhaust Flow, Thousands kg/hr (lb/hr) 25 (85) 20 (68) 3000 (4023) 275 (527) 100 (220) 90 (198) 80 (176) 70 (154) 15 (51) 10 (34) 1000 (1341) (-40) (-22) (-4) (14) (32) (50) (68) (86) (104) (122) INLET AIR TEMPERATURE, C ( F) DS100CS-002M Package Dimensions TURBINE AIR INLET TURBINE EXHAUST 3563 mm (11' 8-1/4") 8611 mm (29' 6") 5512 mm (18' 1") Typical Weight: kg (161,616 lb) Width: 2794 mm (9' 2") DS100CS-003M Solar Turbines Incorporated P.O. Box San Diego, CA U.S.A. Caterpillar is a trademark of Caterpillar Inc. Solar, Mars, SoLoNO x, and Turbotronic are trademarks of Solar Turbines Incorporated. Specifications subject to change without notice. Printed in U.S.A Solar Turbines Incorporated. All rights reserved. DS100CS/699/2M FOR MORE INFORMATION Telephone: (+1) Telefax: (+1) Internet:

7 SATURN 20 Industrial/Utility Grade Features Industrial Gas Turbine Package Compact, Integrated Package Providing Ease of Installation Factory Tested Multiple Fuel Capability Onskid Microprocessor-Control with Auto Sync Capability Package Arrangement Gas Turbine Saturn 20 Industrial, Single-Shaft Axial Compressor 8 Stages Annular Combustion Chamber 12 Fuel Injectors Coatings Compressor: Inorganic Aluminum Turbine and Nozzle Blades: Precious Metal Diffusion Aluminide Velocity Vibration Transducers Main Reduction Drive Epicyclic 1800 or 1500 rpm Acceleration Vibration Transducers Generator Salient Pole, 3 Phase, 6 Wire, Wye Connected, Synchronous with Brushless Exciter Open Drip-Proof Construction Sleeve Bearings Velocity Vibration Transducers Solid-State Voltage Regulation with Permanent Magnet Generator NEMA Class H Insulation with H Rise Continuous Duty Rating Package Steel Base Frame with Drip Pans Direct-Drive AC or Pneumatic Start System Natural Gas Fuel System Microprocessor-Based PLC Generator Control Vibration and Temperature Monitoring Auto Synchronizing Integrated Lube Oil System Turbine-Driven Lube Pump AC Pre/Post Lube Pump Air/Oil Cooler Integral Lube Oil Tank Lube Oil Filter Documentation Drawings Quality Control Data Book Inspection and Test Plan Test Reports O&M Manuals Factory Testing of Turbine and Package Weatherproof Acoustic Enclosure Optional Equipment/Services Generator Options: Standby Duty Rating Standard Voltages: 380, 415, Hz; 240, , Hz Fuel Systems Liquid Dual (Gas/Liquid) Water Injection for NOx Control Alternate Fuels (such as naphtha, propane, low Btu) Lube Oil System Water/Oil Lube Cooler Electrostatic Demister Lube Oil Tank Heater Remote Display/Control Terminal Heat Recovery Application Interface Serial Link Supervisory Interface KW Control KVAR/Power Factor Control Accessory Equipment Turbine Cleaning System: On-Crank and On-line Package Lifting Kit Ancillary Equipment: Various Air Inlet and Exhaust Systems Inlet and Exhaust Silencers Self-Cleaning or Prefilter/Barrier Air Inlet Filter Inlet Evaporative Cooler Inlet Chiller Coils Ancillary Support Frame

8 22 (50) 21 (48) SATURN 20 Nominal Performance* Output Power, kwe ISO: 15 C (59 F), sea level 1210 Available Performance (18.8) Heat Rate, kj/kwe-hr (Btu/kWe-hr) (13,972) Exhaust Flow, kg/hr (lb/hr) (51,240) Exhaust Temperature, C 516 ( F) (960) * No inlet or exhaust losses Relative humidity 60% Natural gas fuel with LHV = 31.5 to 43.3 MJ/nm 3 (800 to 1100 Btu/scf) OUTPUT POWER AT GENERATOR TERMINAL, kwe (13.6) 3.5 (12) 3.0 (10.2) 2.5 (8.5) 5.0 (17.1) 4.5 (15.4) Exhaust Temperature, C ( F) Fuel Flow, MW (MMBtu/hr) 300 (572) Full Load Output Exhaust Flow, Thousands kg/hr (lb/hr) 350 (662) 550 (1022) 500 (932) 450 (842) 400 (752) (58) 25 (56) 250 (482) 2.0 (6.8) 24 (54) 23 (52) (-22) -10 (14) 10 (50) 30 (86) 50 (122) INLET AIR TEMPERATURE, C ( F) DS20IPG-002M Typical Package Configuration PACKAGE GAUGE PANEL ENCLOSURE VENT FAN (Inside) VENT SILENCER ENCLOSURE VENT AIR INLET PACKAGE CONTROL CONSOLE LUBE OIL COOLER TURBINE AIR INLET CLEANER ENCLOSURE VENT AIR EXHAUST TURBINE EXHAUST 2134 mm (7' 0") TURBINE AIR INLET TURBINE AIR INLET ENCLOSURE VENT AIR EXHAUST 813 mm (2' 8") LUBE OIL TANK HEATER (Inside) 5982 mm(19' 7-1/2") Weight: 8980 kg (19,800 lb) 1727 mm (5' 8") DS20IPG-003M Solar Turbines Incorporated P.O. Box San Diego, CA Caterpillar is a trademark of Caterpillar Inc. Solar and Saturn are trademarks of Solar Turbines Incorporated. Specifications subject to change without notice. Printed in U.S.A Solar Turbines Incorporated. All rights reserved. DS20IPG/1198/5M FOR MORE INFORMATION Telephone: (+1) Telefax: (+1) Telex: Internet:

9 TAURUS 60 Industrial/Utility Grade Features Industrial Gas Turbine Package Compact, Integrated Package Providing Ease of Installation Factory Tested Dry, Low Emission (SoLoNOx ) Combustion Available Onskid Microprocessor-Control with Auto Sync Capability Multiple Fuel Capability Package Arrangement Gas Turbine Taurus 60 Industrial, Single-Shaft Axial Compressor 12 Stages Annular Combustion Chamber 12 Fuel Injectors Coatings Compressor: Inorganic Aluminum Turbine and Nozzle Blades: Precious Metal Diffusion Aluminide Proximity Probe Vibration Transducers Main Reduction Drive Epicyclic 1800 or 1500 rpm Acceleration Vibration Transducers Generator Salient Pole, 3 Phase, 6 Wire, Wye Connected, Synchronous with Brushless Exciter Open Drip-Proof Construction Sleeve Bearings Velocity Vibration Transducers Solid-State Voltage Regulation with Permanent Magnet Generator NEMA Class F Insulation with F Rise Continuous Duty Rating Package Steel Base Frame with Drip Pans Direct-Drive AC Start System Natural Gas Fuel System Microprocessor-Based PLC Generator Control Vibration and Temperature Monitoring Auto Synchronizing Integrated Lube Oil System Turbine-Driven Lube Pump AC Pre/Post Lube Pump Backup Lube Pump Air/Oil Cooler Integral Lube Oil Tank Lube Oil Tank Heater Lube Oil Filter Documentation Drawings Quality Control Data Book Inspection and Test Plan Test Reports O&M Manuals Factory Testing of Turbine and Package Optional Equipment/Services Generator Options: WPII, TEWAC Standby Duty Rating Standard Voltages: 3300, 6600, 11, Hz; 4160, 6900, 12,470, 13, Hz Fuel Systems Liquid Dual (Gas/Liquid) SoLoNOx, Dry, Low Emission Alternate Fuels (such as naphtha, propane, low Btu) Lube Oil System Water/Oil Lube Cooler Electrostatic Demister Duplex Lube Oil Filters Remote Display/Control Terminal Heat Recovery Application Interface Serial Link Supervisory Interface KW Control KVAR/Power Factor Control Turbine Performance Map Historical Displays Printer/Logger Predictive Emissions Monitoring Field Programming Terminal Accessory Equipment 24-VDC Battery/Charger System Turbine Cleaning System: On-Crank and On-line Package Lifting Kit Weatherproof Acoustic Enclosure Ancillary Equipment: Various Air Inlet and Exhaust Systems Inlet and Exhaust Silencers Self-Cleaning or Prefilter/Barrier Air Inlet Filter Inlet Evaporative Cooler Inlet Chiller Coils Ancillary Support Frame

10 TAURUS 60 Nominal Performance* Available Performance Output Power, kwe ISO: 15 C (59 F), sea level (72) Heat Rate, kj/kwe-hr (Btu/kWe-hr) (11,263) Exhaust Flow, kg/hr (lb/hr) (174,798) Exhaust Temperature, C 486 ( F) (906) * No inlet or exhaust losses Relative humidity 60% Natural gas fuel with LHV = 31.5 to 43.3 MJ/nm 3 (800 to 1100 Btu/scf) OUTPUT POWER AT GENERATOR TERMINAL, MWe (65) Full Load Output 17 (58) Fuel Flow, MW (MM Btu/hr) 15 (51) 13 (44) Exhaust Temperature, C ( F) 11 (38) 9 (31) 300 (572) 550 (1022) 500 (932) 450 (842) 400 (752) 350 (662) Exhaust Flow, Thousands kg/hr (lb/hr) (392) 89 (196) 86 (190) 250 (482) 83 (183) 80 (176) 7 (24) 77 (170) 74 (163) 71 (157) 68 (150) -40 (-40) -20 (-4) 0 (32) 20 (68) 40 (104) INLET AIR TEMPERATURE, C ( F) DS60IPG-002M Typical Service Connections Forward End Turbine Control Box Length: 9754 mm (32 0 ) Width: 2438 mm (8 0 ) Height: 2591 mm (8 6 ) Approx. Weight: Forward End kg (64,590 lb) Left Side Lube Oil: Drain, Vent, Cooler Generator Control Box, Power Generator Drip Pan Drain AC Power Lube Tank Heater Pre/Post Lube Pump Backup Lube Pump Right Side Left Side AC Power - Start Motor Generator Monitor Box Aft End Aft End DS60IPG-003M Fuel Inlet Turbine Cleaning Fuel Filter, Combustor and Exhaust Collector Drains Auxiliary Air (optional) for: Liquid Fuel Atomizing Self-Cleaning Filter AC Power Liquid Fuel Pump (optional) Package Ground Solar Turbines Incorporated P.O. Box San Diego, CA Caterpillar is a trademark of Caterpillar Inc. Solar, Taurus and SoLoNOx are trademarks of Solar Turbines Incorporated. Specifications subject to change without notice. Printed in U.S.A Solar Turbines Incorporated. All rights reserved. DS60IPG(5200)/1198/5M FOR MORE INFORMATION Telephone: (+1) Telefax: (+1) Telex: Internet:

11 TAURUS 60 Mobile Power Unit Mobile Power - When and Where You Need It The Taurus 60 Mobile Power Unit is the prime choice if you re looking to produce reliable, low-cost, onsite peaking power. Designed as an onsite generator system to optimize service for seasonal or cyclical loads, the Taurus 60 Mobile Generator System includes these key features: Easy to Install and Relocate Highway Transportable Modular Design for Quick Set-Up and Connection No Concrete Foundation Required Compact Footprint to Minimize Space Requirements Ideal for Rental Fleets and Utility Equipment Pools Environmentally Friendly Low Emissions State-of-the-Art SoLoNOx Dry Low NOx Combustion System No Visible Emissions Sound Attenuation Package for Quiet Operation Low Profile Design to Minimize Installed Height Easy to Permit Flexible Solution Leasing and Rental Options Available 5-MW Size for Highly Flexible Capacity Addition and Operation Fuel Flexibility, Gas or Diesel with Dual Fuel Option Complete Systems Solution Set-Up and Commissioning Site Preparation (if needed) Ancillary Support Systems (if needed) Wide Range of Product Support Programs Operational Features Dispatchable to be On Line in Six Minutes (from cold start) Range of Control System Options for Remote Operation and SCADA Integration Utility Grade Switchgear and Protective Relay Module KVAR Control for Excellent Reactive Power Capability

12 TAURUS 60 Mobile Power Unit Nominal Generator Set Performance At the core of the Mobile Power Unit is the 5.5 MW Taurus 60 industrial gas turbine, with a population of more than 1085 units in the field. The Mobile Power Unit combines the features and benefits of the proven Taurus 60 industrial gas turbine with a mobile system that is easy to relocate and connect. OUTPUT POWER, KWe OUTPUT POWER Output Power, kwe ISO: 15 C (59 F), sea level 5,500 Heat Rate, Btu/kWe-hr 11, (5) (32) (59) (86) INLET AIR TEMPERATURE, C ( F) 45 (113) Typical Dimensions TURBINE INLET AIR FILTER OIL MIST ELIMINATOR GAS FUEL FILTER EXHAUST STACK AND SILENCER GAS FUEL METER ATOMIZING AIR COMPRESSOR TURBINE INLET AIR FILTER EXHAUST STACK TRAILER UP TAURUS 60 GEN SET ACCESS PLATFORM LIQUID FUEL FILTER SKID 8' 6" 4' 0" 25' 0" OIL MIST ELIMINATOR EXHAUST SILENCER PREFABRICATED POWER CONTROL ROOM TRAILER AUXILIARY LUBE OIL TRANSFORMER UP COOLER 27' 0" 6' 10" 12' 1" GROUND RESISTOR 5' 3" 5' 1/4" 3' 6" INSTALLATION PLAN VIEW GENERATOR MODULE AUXILIARY TRANSFORMER LUBE OIL COOLER GROUND RESISTOR PREFABRICATED POWER CONTROL ROOM 13' 10" 10' 0" 8' 6" 23' 7" 14' 7/8" LIQUID FUEL FILTER SKID 8' 7" ATOMIZING AIR COMPRESSOR 5' 4-1/2" POWER CONTROL MODULE Mobile Power - When and Where You Need It For information on price, delivery and how the Taurus 60 Mobile Power Unit can meet your needs for short-term capacity and reduce your exposure to market spikes, powergen@solarturbines.com or call (858) Sited Configuration of Taurus 60 Mobile Power Unit Solar Turbines Incorporated P.O. Box MZ SP3-Q San Diego, CA U.S.A. Caterpillar is a trademark of Caterpillar Inc. Solar, Taurus and SoLoNO x are trademarks of Solar Turbines Incorporated. Specifications subject to change without notice. Printed in U.S.A Solar Turbines Incorporated. All rights reserved. DS60MPU/702/4M FOR MORE INFORMATION Telephone: (+1) Telefax: (+1) powergen@solarturbines.com Internet:

13 TAURUS 70 Industrial/Utility Grade Standard Package Configurations Optional Equipment Gas Turbine Taurus 70 Industrial, Single-Shaft Axial Compressor 14-Stage Variable Inlet Guide Vanes and Stators Compression Ratio 16:1 Inlet Airflow: 26.2 kg/sec (57.7 lb/sec) Speed: 15,200 rpm Vertically Split Case Annular Combustion Chamber Conventional or Lean-Premixed, Dry, Low Emission (SoLoNO x) 12 Fuel Injectors Torch Ignitor System Proximity Probe Vibration Transducers Turbine 3-Stage, Axial Flow Speed: 15,200 rpm Main Reduction Drive Epicyclic 1500 or 1800 rpm (50 or 60 Hz) Acceleration Vibration Transducer Generator Continuous Duty Rating Salient Pole, 3 Phase, 6 Wire, Wye Connected, Synchronous with Brushless Exciter Permanent Magnet Generator Open Drip-Proof Construction Sleeve Bearings Velocity Vibration Transducers NEMA Class F Insulation with F Rise Package Steel Base Frame with Drip Pans Direct-Drive AC Start System Natural Gas Fuel System Turbotronic 4 Control System ControlLogix Processor Standard Display with Discrete Event Log, Strip Chart, Historical Trend, Maintenance Screen Gas Turbine and Generator Control Vibration and Temperature Monitoring Auto Synchronizing KW Control CGCM Module KVAR/Power Factor Control (Optional) Combination Generator Control Module with Load Share, Synchronization, Voltage Control, Reactive Power Control, Generator Protection Integrated Lube Oil System Turbine-Driven Lube Pump Pre/Post Lube Pump Backup Lube Pump Air/Oil Cooler Integral Lube Oil Tank Lube Oil Tank Heater Simplex Lube Oil Filter Oil Mist Eliminator Documentation Drawings Quality Control Data Book Inspection and Test Plan Test Reports Operation and Maintenance Manuals Turbine Cleaning System: On-Crank and On-Line Factory Testing of Turbine and Package Generator Options: Totally Enclosed Water/Air Cooled Standard Voltages: 6600, 11,000 V (50 Hz); 4160, 12,470, 13,800 V (60 Hz) Fuel Systems Liquid Dual (Gas/Liquid) Alternate Fuels (such as naphtha, propane, low Btu gas) ElectricFuel Control Lube Oil System Water/Oil Lube Oil Cooler Duplex Lube Oil Filters Vent Flame Trap Auxillary and Remote Display/ Control Terminal Heat Recovery Application Interface Serial Link Supervisory Interface Turbine Performance Map Historical Displays Printer/Logger Field Programming Terminal Accessory Equipment 120-VDC Battery/Charger System Package Lifting Kit Weatherproof Acoustic Enclosure Ancillary Equipment: Inlet and Exhaust Silencers Self-Cleaning or Prefilter/Barrier Air Inlet Filter Inlet Evaporative Cooler Inlet Chiller Coils Ancillary Support Frame

14 F1 F9 F2 F10 F3 F11 F4 F12 F5 F F6 F14 F7 F15 F8 F TAURUS 70 Nominal Performance* Available Performance Output Power, kwe 7520 ISO: 15 C (59 F), sea level (238) Exhaust Flow, Thousands kg/hr (lb/hr) Heat Rate, kj/kwe-hr (Btu/kWe-hr) (10,100) Exhaust Flow, kg/hr (lb/hr) (213,840) Exhaust Temperature, C 490 ( F) (910) * No inlet or exhaust losses Relative humidity 60% Natural gas fuel with LHV = 31.5 to 43.3 MJ/nm 3 (800 to 1100 Btu/scf) OUTPUT POWER AT GENERATOR TERMINAL, MWe (89) 24 (82) 22 (75) 20 (68) 18 (61) 16 (55) 14 (48) 12 (41) 500 (932) 104 (229) 100 (220) Full Load Output 300 (572) 450 (842) Exhaust Temperature, C ( F) Fuel Flow, MW (MM Btu/hr) 350 (662) 96 (212) 92 (203) 88 (194) 84 (185) 400 (752) 10 (34) 250 (482) 1-40 (-40) -20 (-4) 0 (32) 20 (68) 40 (104) INLET AIR TEMPERATURE, C ( F) DS70IPG-002M Typical Service Connections Forward End Left Side Aft End DS70IPG-003M Right Side Lube Oil Tank Vent Package Dimensions Length: mm (37 0 ) Width: 2932 mm (9 7-7/16 ) Height: 2743 mm (9 0 ) Approximate Weight (dry): kg (110,923 lb) Left Side Lube Oil: Cooler, Drain, Vent AC Power Starter Motor Liquid Fuel Pump Pre/Post Lube Pump Oil Tank Heater Package Ground DC Power, Backup Lube Pump Lube Oil Tank Drain Forward End Turbine Control Box Generator Drip Pan Drain Package Ground Generator Control Box Generator Terminal Box Aft End Combustor and Exhaust Diffuser Drains Fuel: Inlet, Filter, Drain, Vent Auxiliary Air (optional) for: Liquid Fuel Atomizing Self-Cleaning Filter Turbine Cleaning Turbine Drip Pan Drain Solar Turbines Incorporated P.O. Box San Diego, CA U.S.A. Caterpillar is a trademark of Caterpillar Inc. Solar, Taurus, SoLoNOx and Turbotronic are trademarks of Solar Turbines Incorporated All other trademarks are the intellectual property of their respective companies.. Specifications subject to change without notice. Printed in U.S.A Solar Turbines Incorporated. All rights reserved. DS70PG/103/1M FOR MORE INFORMATION Telephone: (+1) Telefax: (+1) Internet:

www.opraturbines.com Gas Turbine Power COMPACT, EFFICIENT, RELIABLE

www.opraturbines.com Gas Turbine Power COMPACT, EFFICIENT, RELIABLE www.opraturbines.com Gas Turbine Power COMPACT, EFFICIENT, RELIABLE T U R B I N E S About OPRA Turbines King Olav V of Norway with Jan Mowill and the KG2 in 1969 Production of OP16 generating sets in Hengelo,

More information

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT-100 4.9 MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station

INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT-100 4.9 MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station D & S Turbine International LLC INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT-100 4.9 MW / 5340 KVA 50Hz 11KV Duel Fuel Power Station INDUSTRIAL POWER GENERATION EQUIPMENT Typhoon SGT-100 4.9 MW /

More information

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001. This generator set has been designed to meet ISO 88 regulation. This generator set is manufactured in facilities certified to ISO 900. This generator set is available with CE certification. Enclosed product

More information

Turbomachinery Systems

Turbomachinery Systems P O W E R I N G T H E G L O B A L E N E R G Y D E M A N D Turbomachinery Systems For Oil and Gas Applications Compressor Sets Mechanical Drive Sets Generator Sets Centrifugal Gas Compressors Performance

More information

Annex-A TECHNICAL SPECIFICATION

Annex-A TECHNICAL SPECIFICATION Annex-A TECHNICAL SPECIFICATION FOR SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF 0.4kV (2,000kVA) DIESEL GENERATOR 1 1.0 SCOPE This specification covers the requirements of design, manufacture, delivery

More information

Shared Technologies in the Development of the Titan 250 TM Gas Turbine System

Shared Technologies in the Development of the Titan 250 TM Gas Turbine System Paper No: 09-IAGT-102 INDUSTRIAL APPLICATION OF GAS TURBINES COMMITTEE Shared Technologies in the Development of the Titan 250 TM Gas Turbine System by Mark S. Knodle Program Manager Titan 250 Gas Turbine

More information

Introduction of the Solar Turbines Titan 250 Gas Turbine System

Introduction of the Solar Turbines Titan 250 Gas Turbine System Introduction of the Solar Turbines Titan 250 Gas Turbine System Design, Development and Validation Testing a New 22.4 MW Gas Turbine VGB Fachtagung 24-JUN-2009 Mannheim, Germany Ulrich Stang Manager Turbine

More information

Magnum Mobile Generator MMG55 Specifications

Magnum Mobile Generator MMG55 Specifications Empowering Real People Magnum Mobile Generator MMG55 Specifications ENGINE John Deere PE5030TF270 - turbocharged, diesel engine o Prime - 72 hp @ 1800 rpm o Standby - 80 hp @ 1800 rpm o 4 cylinder o 3.0

More information

Technical Specification. Generating Set with Waukesha engine burning natural gas

Technical Specification. Generating Set with Waukesha engine burning natural gas Technical Specification Generating Set with Waukesha engine burning natural gas The following presents the Gas Engine Generating Set (GEGS) APG1000 type, based on Waukesha gas engine 16V150LTD. Using the

More information

26 3213.13 Diesel Engine Driven Generators Page 1 of 6

26 3213.13 Diesel Engine Driven Generators Page 1 of 6 Last Update: December 8, 2014 A. Description of System Consultant s Handbook Page 1 of 6 1. Provide a diesel engine driven electric generating unit, factory assembled, tested and certified to operate at

More information

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET STANDBY 320 ekw 400 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm

4000 Series 4008TAG2A Diesel Engine ElectropaK 947 kwm @ 1500 rpm The Perkins 4000 Series family of 6, 8, 12 and 16 cylinder diesel engines was designed in advance of today s uncompromising demands within the power generation industry and includes superior performance

More information

DIESEL GENERATOR SETS

DIESEL GENERATOR SETS DIESEL SETS STANDBY Standby Prime Model kw (kva) kw (kva) D175-2* 175 (218.8) 157.5 (196.9) *Tier 3 EPA Approved, Emissions Certified Picture shown may not reflect actual package FEATURES SET Complete

More information

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer

GEP550 (3-Phase) 50 HZ. 500 kva / 400 kw FEATURES. Exclusively from your Caterpillar dealer D I E S E L G E N E R A T O R S E T GEP550 (3-Phase) 50 HZ STANDBY PRIME 550 kva / 440 kw 500 kva / 400 kw FEATURES GENERATOR SET Complete system designed and built at ISO9001 certified facility Factory

More information

Diesel Generating Set

Diesel Generating Set MODEL Standby Power(50Hz) Prime Power(50Hz) 44KW /55KVA 40KW /50KVA Standard Features General Features: Engine( DCEC Cummins 4BTA3.9 -G) Radiator 40 O C max,fans are driven by belt, with safety guard 24V

More information

Micro-Turbine Combined Heat & Power Generators (CHP) Cold Climate Applications 2014 Polar Technology Conference Richard S.

Micro-Turbine Combined Heat & Power Generators (CHP) Cold Climate Applications 2014 Polar Technology Conference Richard S. Micro-Turbine Combined Heat & Power Generators (CHP) Cold Climate Applications 2014 Polar Technology Conference Richard S. Armstrong, PE DISTRIBUTED CO-GENERATION DEFINED Electricity and Heat production

More information

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET

DIESEL GENERATOR SET. 60 Hz FEATURES GENERATOR SET DIESEL SET STANDBY Model Standby Prime kw (kva) kw (kva) D40-4 40 (50) 36 (45) D40-4S 40 (40) 36 (36) D50-4 50 (62.5) 45 (56.3) D50-4S 50 (50) 45 (45) D60-4 60 (75) 54.6 (68.2) All models are Tier II EPA

More information

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014

III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III. Roof Mount AC Mobile Climate Control 19 MCC Reference Manual 2014 III.1. Large Roof Mount PN: 89-3037 Roof Mount Unit Eco 136 Parallel roof mount Air-conditioning and ventilation systems The Eco 136

More information

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw

DLW 8. POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw DLW 8 POWER RATING 1500 rpm/50 Hz 1800 rpm/60 Hz Prime 7.5 kva, 6 kw 9.1 kva, 7.3 kw Standby 8.5 kva, 6.8 kw 10.1 kva, 8.1 kw Generator set consisting of engine and alternator mounted on a fabricated steel

More information

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ

AGP15 Perkins Series Gen Set Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ Stand-by Specification Sheet Stand by Rating - 15KW (20KVA) Continuous Rating 13KW(18KVA) 60HZ Standard Features 3 Cylinder Diesel Engine for maximum durability, reliability and efficiency. Brushless alternator

More information

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts

STANDBY 800 ekw 1000kVA 60 Hz 1800rpm 480Volts DIESEL GENERATOR SET Image shown may not reflect actual package. STANDBY 800 ekw 1000kVA Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility,

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw ,1'8675,$/#*(16(7 6HULHV#'9#448 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 113 kva, 90 kw 124 kva, 99 kw 6WDQGE\ 114 kva, 91 kw 125 kva, 100 kw Generator set consisting of engine and alternator mounted

More information

C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm

C18 ACERT Fire Pump Tier 3 448 bkw/600 bhp @ 1750 rpm CATERPILLAR ENGINE SPECIFICATIONS I-6, 4-Stroke-Cycle Diesel Bore...145.0 mm (5.71 in) Stroke...183.0 mm (7.2 in) Displacement... 18.1 L (1,104.53 in3) Aspiration...Turbocharged Aftercooled Compression

More information

SIOUX HYBRID WATER HEATER

SIOUX HYBRID WATER HEATER SIOUX Hybrid Water Heater for the Concrete Industry SIOUX HYBRID WATER HEATER Patent Pending Maximizing the Benefits of Coil and Direct-Fired Heating Technologies Higher Discharge Temperature True High-Efficiency

More information

Medical Air Systems: Scroll

Medical Air Systems: Scroll GENERAL The Chemetron skid mount scroll medical air system is designed to provide medical breathing air for hospital and medical institutions. This system meets NFPA 99 requirements for Level 1 breathing

More information

IV. Rear Mount System

IV. Rear Mount System Mobile Climate Control 45 MCC Reference Manual 2014 PN: 89-3069 Rearmount Air Conditioning System Eco RM Capacity, Reliability, and Serviceability MCC Eco RM unit, selected as preferred equipment by leading

More information

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) 100 mhp @ 1200 rpm

3304B. Marine Auxiliary Engine SPECIFICATIONS STANDARD EQUIPMENT ACCESSORY EQUIPMENT PERFORMANCE DATA. 56 bkw (75 bhp) 100 mhp @ 1200 rpm Marine Auxiliary Engine SPECIFICATIONS 3304B 56 bkw (75 bhp) 100 mhp @ 1200 rpm Shown with Accessory Equipment I-4, 4-Stroke-Cycle-Diesel Emissions...IMO compliant Displacement... 7.0 L (425 cu. in.) Bore...

More information

ECOCIAT. Domestic hot water heat recovery unit

ECOCIAT. Domestic hot water heat recovery unit Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY

More information

European Aviation Safety Agency

European Aviation Safety Agency European Aviation Safety Agency EASA TYPE CERTIFICATE DATA SHEET Number : IM.E.026 Issue : 04 Date : 04 April 2014 Type : Engine Alliance LLC GP7200 series engines Models: GP7270 GP7272 GP7277 List of

More information

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw

CAT NEXT GENERATION DIESEL GENERATOR SETS. C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw CAT NEXT GENERATION DIESEL GENERATOR SETS C15 ACERT and C18 ACERT 410-700 kva / 365-600 ekw THE NEXT GENERATION CAT DIESEL GENERATOR SET FEATURES SEVERAL KEY DESIGN AND PERFORMANCE ENHANCEMENTS TO ITS

More information

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 50HZ MP Series MPS180S 1 / MPS180 1 MPS180S 1 / MPS180 1 MP Series Features Compact structure with high strength chassis; Easy operation and maintenance,

More information

Load Bank Buyers Guide 60 hz models

Load Bank Buyers Guide 60 hz models Load Bank Buyers Guide 60 hz models Quality System Certified to ISO 9001 www.avtronloadbank.com power test solutions Avtron LoadBank, Inc. Since 1953, Avtron has been a leader in the design and manufacture

More information

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw

32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw ,QGXVWULDO#*HQHUDWRU 32:(5#5$7,1* 4833#USP283#+] 4;33#USP293#+] 3ULPH 10.4 kva, 8.3 kw 12.9 kva, 10.3 kw 6WDQGE\ 11.3 kva, 9 kw 14.4 kva, 11.5 kw Generator set consisting of engine and alternator mounted

More information

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK CL - CH - CK Direct driven solution for industry Proven technology, solid construction The CL - CH - CK units are directly driven air-cooled, single

More information

300 Series PA Pump and Cooler Assemblies

300 Series PA Pump and Cooler Assemblies Type 300 Series PA Sizes 300 thru 370 (Page 1 of 9) 300 Series PA Pump and Cooler Assemblies Pump and Cooler Assemblies with Air/Oil Heat Exchanger When compact gear drives require assistance to dissipate

More information

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer

GEP150 (3-Phase) 50 HZ 60 HZ. 150 kva / 120 kw FEATURES. Exclusively from your Caterpillar dealer D I E S E L G E N E R A T I N G S E T GEP150 (3-Phase) 50 HZ STANDBY PRIME 60 HZ STANDBY PRIME 150 kva / 120 kw 135 kva / 108 kw 165 kva / 132 kw 150 kva / 120 kw FEATURES GENERATING SET Complete system

More information

MAC-120HE-01 Air-Cooled Chiller

MAC-120HE-01 Air-Cooled Chiller MAC-120HE-01 Air-Cooled Chiller 10 Ton / 120,000 BTUH Air-Cooled Chiller 208/230-1-50/60 1 HVAC Guide Specifications Air-Cooled Liquid Chiller Nominal Size: 10 Tons Multiaqua Model Number: MAC-120HE-01

More information

Nirvana. Cycling Refrigerated Dryers

Nirvana. Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Nirvana Cycling Refrigerated Dryers Reliability Is Our Design Ingersoll Rand's Nirvana Cycling Refrigerated Dryer provides reliability like no other dryer in its class:

More information

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors

POLARIS AIR COMPRESSOR SERIES. engineering. excellence. stellar. performance. A World Leader for Centrifugal Compressors POLARIS AIR COMPRESSOR SERIES engineering excellence stellar performance P - 3 0 0 RELIABLE 100% OIL-FREE ENGINEERED AIR A World Leader for Centrifugal Compressors It s simple: The Polaris Air Compressor

More information

How To Use A Cat Diesel Engine

How To Use A Cat Diesel Engine DIESEL GENERATOR SET STANDBY 440 ekw 550 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Visions become real. Temperature control and cooling systems. The innovative and reliable solution

Visions become real. Temperature control and cooling systems. The innovative and reliable solution Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature

More information

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours:

Current state of plant Functioning as a peak and emergency centre. Statistics Accumulated operating hours: Current state of plant Functioning as a peak and emergency centre Statistics Accumulated operating hours: D1-2-3-6-7: 43000 to 48000 hrs D4-5: 53000 to 57000 hrs D8: 33000 hrs Layout of the plant Index:

More information

With Rolls-Royce Aero Engine Technology. The Industrial 501-K Gas Turbine. siemens.com

With Rolls-Royce Aero Engine Technology. The Industrial 501-K Gas Turbine. siemens.com With Rolls-Royce Aero Engine Technology The Industrial 501-K Gas Turbine siemens.com 2 / Industrial 501-K Gas Turbines Industrial 501-K gas turbine Dependable, flexible design for onshore and offshore

More information

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com.

Titan Makina Ltd. Şti. 1160. Sok. No: 9 Ostim 06370 Ankara Tel: + 90 312 354 9977 Fax: + 90 312 385 5611 Web: www.titanltd.com. IS26 Concrete Spraying Machine IS26 Concrete Spraying Machine TECHNICAL SPECIFICATIONS Manipulator Max. vertical spraying reach : Max. horizontal spraying reach : Working lights : Spraying Head Rotation

More information

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM SECTION 23 81 03 - PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Packaged rooftop air conditioning unit (5 tons and smaller). 2. Roof curb. 1.2

More information

Industrial Power. SGT-800 Gas Turbine. Power Generation: (ISO) 47.5 MW(e) / 50.5 MW(e) www.siemens.com / energy

Industrial Power. SGT-800 Gas Turbine. Power Generation: (ISO) 47.5 MW(e) / 50.5 MW(e) www.siemens.com / energy Industrial Power SGT-800 Gas Turbine Power Generation: Simple Cycle Combined Cycle 2x1 (ISO) 47.5 MW(e) / 50.5 MW(e) (ISO) 135.4 MW(e) / 143.6 MW(e) www.siemens.com / energy Nomenclature SC: CC: SCC: DLE:

More information

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16)

XQ20 RENTAL. 60 Hz. Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16) RENTAL Standby Prime Voltage kw (kva) kw (kva) 208/120V 3 PH 20 (25) 18 (22.5) 480/277V 3 PH 20 (25) 18 (22.5) 240/120V 1 PH 17 (17) 16 (16) Shown with optional trailer FEATURES EPA TIER 4 AND CARB CERTIFIED

More information

Design and Test Operation Performance of 1,500 C Class Gas Turbine Combined-Cycle Power Plant:

Design and Test Operation Performance of 1,500 C Class Gas Turbine Combined-Cycle Power Plant: 31 Design and Test Operation Performance of 1,500 C Class Gas Turbine Combined-Cycle Power Plant: Construction of Group 1 of the Tokyo Electric Power Company s Kawasaki Thermal Power Station KIYOSHI KAWAKAMI

More information

Spark-ignited generator set

Spark-ignited generator set Specification sheet Spark-ignited generator set 30 60 kw standby EPA emissions Description Cummins Power Generation commercial generator sets are fully integrated power generation systems providing optimum

More information

Micro cogeneration. Affordable, efficient and innovative

Micro cogeneration. Affordable, efficient and innovative Micro cogeneration Affordable, efficient and innovative A compact and efficient solution A compact and efficient solution Organisations are increasingly looking for environmentally friendly systems to

More information

Marine Generating Sets 3.7 to 50 kva

Marine Generating Sets 3.7 to 50 kva Marine Generating Sets 3.7 to 50 kva The Marine Engineer s Preference BetaSet - Standard Marine Generators Beta Marine has considerable experience from over twenty years of manufacturing marine generating

More information

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption

DIESEL FEATURES GENERATOR SET. FUEL/EMISSIONS STRATEGY Low fuel consumption IE DIESEL FEATURES GENERATOR SET PRIME 2000 ekw 2500 kva Caterpillar is leading the power generation Market place with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability,

More information

WINDOW ROOM AIR CONDITIONER

WINDOW ROOM AIR CONDITIONER WINDOW ROOM AIR CONDITIONER Installation and Operation Manual Electromechanical Remote Control CAPACITIES 220V - 60 HZ. 12,000; 18,000; 24000 BTU/HR 220V-240V - 50 HZ. 12,000; 18,000; 24000 BTU/HR Please

More information

york air-conditioning products Residential & VRF News 2015

york air-conditioning products Residential & VRF News 2015 york air-conditioning products Residential & VRF News 2015 york air-conditioning products Catalogue Content Split Systems Pag. High wall High Efficiency Inverter YWHJZH 09 to 24 K 6 High wall Inverter

More information

The 26 200 kva RAnge

The 26 200 kva RAnge The 26 200 kva Range The new 26 200 kva range...designed to Deliver More. We understand the unique needs of generating set customers around the world. Forty years experience combined with the latest technology

More information

Half the cost Half the carbon

Half the cost Half the carbon Half the cost Half the carbon the world s most efficient micro-chp What is BlueGEN? The most efficient small-scale electricity generator BlueGEN uses natural gas from the grid to generate electricity within

More information

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE Fujitsu General realizes considerable energy saving operations by the Heat pump heating system using the ambient

More information

RPV - RP - RA air handling units

RPV - RP - RA air handling units APPLICATIONS Heating, ventilation, cooling >> FACTORIES >> WAREHOUSES >> HALLS >> DISTRIBUTION CENTRES >> COMMERCIAL PREMISES >> PLACES OF WORSHIP RPV - RP - RA air handling units www.reznor.eu RPV - RP

More information

Commercial Gas Furnace Upflow

Commercial Gas Furnace Upflow Commercial Gas Furnace Upflow Model G24-200 80% A.F.U.E. 200,000 Btuh Input Heating Cap. 7.5 or 10 Tons Nominal Add-On Cooling GUK FEATURES Certified by A.G.A./C.G.A. Laboratories. Heavy gauge painted

More information

Guidelines for Preparing for a Temporary Steam Plant

Guidelines for Preparing for a Temporary Steam Plant Guidelines for Preparing for a Temporary Steam Plant Trailer-Mounted Boilers Skid Mounted Boilers Mobile Boiler Rooms Mobile Feedwater Vans Mobile Steam Plants Emergency Preparedness Plan Table of Contents

More information

GE Energy LMS100. Flexible Power

GE Energy LMS100. Flexible Power GE Energy LMS100 Flexible Power GE Energy is a leading supplier of aeroderivative gas turbines and packaged generator sets for industrial and marine applications. We provide power-generating equipment

More information

Gas Turbine Generator Systems

Gas Turbine Generator Systems Gas Turbine Generator Systems Complete Solutions for Your Power Needs Global Experience A leading supplier in mid-range industrial gas turbines and gas turbine-driven generator sets from 1 to 20 MW, Solar

More information

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years

Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years Ingersoll Rand Type-30 Air Ingersoll Rand Providing Customer-Driven Air System Solutions for More Than 100 Years Back then, we called it serving the customer. Today, we call it Solutionizing because your

More information

THM Gas Turbines Heavy duty gas turbines for industrial applications

THM Gas Turbines Heavy duty gas turbines for industrial applications THM Gas Turbines THM Gas Turbines Heavy duty gas turbines for industrial applications Combined advantages The THM 1304 heavy duty gas turbine family consists of two members with ISO power outputs of 10,500

More information

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET

TECHNICAL DATA 60HZ MPMC POWERTECH CORP. DIESEL GENERATING SET TECHNICAL DATA DIESEL GENERATING SET MPMC POWERTECH CORP. 60HZ MC Series MCS600S-2 / MCS600-2 MCS600S-2/ MCS600-2 MC Series Features Reference images, the actual shall prevail Compact structure with high-strength

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Snow Enclosure and Subbase Fuel Tank Package Applicable to the following: 80/100/150REOZJF 125REOZJG Enclosure with Standard Subbase Fuel Tank Enclosure with State

More information

Cooling Capacity CFM range @.5 in. w.c. (125 Pa)

Cooling Capacity CFM range @.5 in. w.c. (125 Pa) N8MXL Product Specifications 80% ECM Single Stage Heating Furnace EASIER TO SELL 80% AFUE Flame roll out sensors standard Category I venting Blocked vent switch 24 VAC humidifier terminal Electronic air

More information

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva

STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 150 ekw 188 kva PRIME 135 ekw 169 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered

More information

Atlas Copco Generators

Atlas Copco Generators Atlas Copco Generators QIX 15 - QIX 540 16 kva LTP to 549 kva LTP at 50 & 60 Hz The QIX options include Earth leakage relay Qc generating set control panels for all standby and/or paralleling applications

More information

CRAC Precision climate control units for data centres

CRAC Precision climate control units for data centres CRAC Precision climate control units for data centres 2 Rittal Computer Room Air Conditioner The whole is more than the sum of its parts The same is true of Rittal The System. With this in mind, we have

More information

UDSA - UDSBD unit heater

UDSA - UDSBD unit heater APPLICATIONS Heating >> FACTORIES >> WAREHOUSES >> HALLS >> SHOWROOMS >> GREENHOUSES >> RETAIL >>... UDSA - UDSBD unit heater www.reznor.eu V3 gas fired unit heater Reznor V3 unit heaters are one of the

More information

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT MAXIMATOR GmbH 2 MAXIMATOR has an extensive know-how concerning concept, development, construction and manufacturing of test benches and

More information

PREVENTIVE MAINTENANCE PROGRAM AND NOVEL TECHNIQUES TO REDUCE DOWNTIME AND INCREASE OPERATING EFFICIENCY AT DISTRIBUTED COGENERATION FACILITIES

PREVENTIVE MAINTENANCE PROGRAM AND NOVEL TECHNIQUES TO REDUCE DOWNTIME AND INCREASE OPERATING EFFICIENCY AT DISTRIBUTED COGENERATION FACILITIES IDEA 2013 February, San Diego PREVENTIVE MAINTENANCE PROGRAM AND NOVEL TECHNIQUES TO REDUCE DOWNTIME AND INCREASE OPERATING EFFICIENCY AT DISTRIBUTED COGENERATION FACILITIES Dorin Scheianu and Tom Le Wood

More information

Natural geothermal energy.

Natural geothermal energy. ROTEX ground source heat pump Natural geothermal energy. ROTEX HPU ground the ground source heat pump that heats with free geothermal energy. Compact, environmentally responsible and uniquely efficient.

More information

industry revolves around

industry revolves around revolves around innovation Throughout its 50 year history Hydrovane has been the market leader in rotary vane compression technology, building an enviable reputation for quality and reliability. As part

More information

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS

NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS GAS GENERATOR SET NATURAL GAS CONTINUOUS 725 ekw 906 kva 745 ekw 931 kva 770 ekw 963 kva 50 HZ 1500 RPM 400 VOLTS Image shown may not reflect actual package Caterpillar is leading the power generation

More information

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

HVAC Preventative Maintenance Basics. Presented by Mike Crawley HVAC Preventative Maintenance Basics Presented by Mike Crawley Air Handlers/Package Units: Coils have to be clean! The main purpose of any coil is to absorb or reject heat If coils are dirty; air flow

More information

Adsorption air dryers ADS 1 215

Adsorption air dryers ADS 1 215 Adsorption air dryers ADS 25 INDUSTRY CUSTOMER SERVICE COMPRESSED AIR AIR INTAKE 20 C 70% UR 760 mm Hg 2 grh 2 O/m 3 AIR PRESSURE 0 bar COOLING SYSTEM 30 C 00% UR 0 bar 2,8 grh 2 O/m 3 A compressor that

More information

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva

STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva DIESEL GENERATOR SET FEATURES Image shown may not reflect actual package. STANDBY 40 ekw 40 kva PRIME 36 ekw 36 kva Caterpillar is leading the power generation marketplace with Power Solutions engineered

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather/Sound and Subbase Package Applicable to the following: 700-1000REOZDE 750-1000REOZMD Weather Standard Features D Internal-mounted, exhaust silencer with rain

More information

GE s TM2500+ solution offers fast, mobile and flexible power

GE s TM2500+ solution offers fast, mobile and flexible power GE Power & Water Distributed Power GE s TM2500+ solution offers fast, mobile and flexible power Power whenever and wherever it s needed GE Power & Water Distributed Power 31 69 ~1 MW power potential on

More information

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pump Eurovacuum EV Series Single Stage Oil Sealed Rotary Vane Pumps Eurovacuum Company is offering its various products to meet industrial vacuum

More information

Commercial Gas Water Heater

Commercial Gas Water Heater Commercial Gas Water Heater 3-Year Limited Tank/1-Year Limited Parts Warranty* The Polaris has a high grade 444 stainless steel tank with brass connections for years of dependable, trouble-free service

More information

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC Technical Concept Filter Fan Unit COMPACT Type COMPACT AC Type COMPACT EC Ultra Filter Fan Unit COMPACT Technical Concept Product Description Filter Fan Units (FFUs) from M+W Products are designed to provide

More information

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO

Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and

More information

Evaluate, Clean, and Tune Guidance

Evaluate, Clean, and Tune Guidance Evaluate, Clean, and Tune Guidance The Evaluate, Clean and Tune (ECT) process serves three essential purposes in the Weatherization Assistance Program (WAP). The first is to evaluate the existing system

More information

Heavy Duty Industrial Air Compressors

Heavy Duty Industrial Air Compressors HEAVY DUTY SERIES - VERTICAL TANK MOUNTED All units mounted on air receivers rated at 200 psi and CRN approved for Canada. All units may be ordered with magnetic starter (Starter supplied loose). All units

More information

Backup Fuel Oil System Decommissioning & Restoration Plan

Backup Fuel Oil System Decommissioning & Restoration Plan Backup Fuel Oil System Page 1 of 19 Overview of Physical Fuel Oil System and Decommissioning Steps The fuel oil system at Milford Power consists of a number of subsystems. These include the following:

More information

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption

DIESEL GENERATOR SET FEATURES. FUEL/EMISSIONS STRATEGY Low Fuel consumption DIESEL GENERATOR SET STANDBY 560 ekw 700 kva Caterpillar is leading the power generation market place with power solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

More information

Frequently Asked Questions Generators

Frequently Asked Questions Generators Frequently Asked Questions Generators Fuel Related How much fuel do the generators use during normal operation? At exercise? The generator fuel consumption is given in each of the product knowledge books

More information

GE Power Conversion. Motors. Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP

GE Power Conversion. Motors. Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP GE Power Conversion Motors Medium / High Voltage and High Speed 190 to 100,000 kw 250 to 134,000 HP 2 GE I Power Conversion GE has been setting the standard in manufacturing motors for over 125 years.

More information

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC & hore nd Offsh arine an ms for Ma geration System & Refrig HV VAC & PRODUCT CATALOGUE AUTONOMOUS AIR CONDITIONERS O ! "# $ % & " ' (! ) * +,+( -../01..2 PRODUCT CATALOGUE 72-17 AUTONOMOUS AIR CONDITIONERS

More information

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES:

Standby Generators FEATURES. Standby Generators Liquid-Cooled Gas Engine. Standby Generators INCLUDES: Standby Generators Liquid-Cooled Gas Engine 1 of 9 INCLUDES: Two Line LCD Tri-Lingual Digital Nexus Controller Isochronous Electronic Governor Sound Attenuated Enclosure Closed Coolant Recovery System

More information

Propane-Fueled Microturbine: Case Study

Propane-Fueled Microturbine: Case Study Propane-Fueled Microturbine: Case Study Potential of Propane as a Microturbine Fuel Microturbine generators are small turbine generators targeted for the distributed generation marketplace and located

More information

Industrial Generator Set Accessories

Industrial Generator Set Accessories Industrial Generator Set Accessories Weather/Sound Enclosure and Subbase Fuel Tank Package Applicable to the following: 40REOZJC 50/60REOZJD 80/100/150/200REOZJF 125/180REOZJG 230-275REOZJE 300REOZJ Enclosure

More information

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE Hot Water Boilers and Controls Why Condensing Boilers are Different Presented Oct. 14, 2008 Long Island Chapter, ASHRAE H.W. Boilers and Controls Major types of boilers Advantages and disadvantages Resistance

More information

Top Technology for Industry, Agriculture, Business and Communities

Top Technology for Industry, Agriculture, Business and Communities Top Technology for Industry, Agriculture, Business and Communities CHP The Technology with a Potential for Saving Energy Combined Heat and Power (CHP) is a highly efficient technology for the conversion

More information

Refrigeration Compressed Air Dryer Buran Ultrapulse

Refrigeration Compressed Air Dryer Buran Ultrapulse Refrigeration Compressed Air Dryer Buran Ultrapulse There is more to compressed air than just compressing air Compressed air is an indispensable source of operating and processing power in all areas of

More information

Offshore Platform Powered With New Electrical Motor Drive System

Offshore Platform Powered With New Electrical Motor Drive System Offshore Platform Powered With New Electrical Motor Drive System Authors: Jan O. Lamell, M.Sc E.E. ABB Automation Technologies Presenters: Thomas Johansson, M.Sc E.E. ABB Automation Technologies Timothy

More information

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping GE Oil & Gas Texsteam * Pumps: precise chemical injection pumping 2 With a wide range of capacities and operating pressures, GE s versatile Texsteam pumps can handle challenging chemical pumping requirements

More information