PARTS & SERVICE MANUAL

Similar documents
Service Manual. 30 Insert. Model Number: EF3003/SF3003/DF3003. UL Part Number (Canadian and Chinese Built) DFB6016 (DFB6016)

Service Manual 33 Wide Screen Fireplace with Full Feature Remote Control

Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

Installation Instructions

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

Service Manual 30 Self Trimming Fireplace Purifire and Mid-line Remote

Table of Contents. What to Expect with. Preparation. Tools Needed. Wiring. Hanging the Fan. Blades. Motor Housing.

Service Manual 32 Purifire Fireplace

OVEN PARTS For Models:GMC305PDB07, GMC305PDQ07, GMC305PDT07, GMC305PDS07 (Black) (White) (Biscuit) (S.Steel)

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

WARNING! REQUIRED TOOLS & SUPPLIES: HIGH VOLTAGE


PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129

Guide for Modified Assembly: Lightning McQueen. By: Collin Patterson, University of Delaware. Materials and Tools:

Bathroom Cabinet. Installation & User Guide. Illuminated Mirrors.

OVEN PARTS For Models:RBS305PDB16, RBS305PDQ16, RBS305PDT16, RBS305PDS16 (Black) (Designer White) (Biscuit) (S.Steel)

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

INSTALL/REMOVAL INSTRUCTIONS: WINDOW REGULATOR

Owners & Installation Manual for the Sheridan, Mountainair, Pine Valley and Old Forge Ceiling Fan Family

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

HP Laser Jet 4200/4240/4250/4300/4350 Swing Plate

Owner s Manual DF3215 DF3215NH. Model Numbers:

SERVICE PARTS LIST PAGE 1 OF 6 BASE ASSEMBLY SPECIFY CATALOG NO. AND SERIAL NO. WHEN ORDERING PARTS 12" DUAL BEVEL COMPOUND MITER SAW B27A

KEYLESS ENTRY UPGRADE SECURITY SYSTEM for 2004 TOYOTA HIGHLANDER

TOYOTA Tundra BACK-UP CAMERA SYSTEM Preparation

Fan, Cypress / GreenField Installation Instructions (sku )

1969 DODGE CORONET Two panel Sequential LED Taillight kit installation guide

INSTALLATION INSTRUCTIONS

Parts Required: Remove the Falcon Wiper Motor:

IMPORTANT SAFETY INFORMATION:

TOYOTA TUNDRA 2015 Billet Grille w/led DRL

PWC-500/1000/1010/1500

P150SC15. Designed for 2015 Ford F150 Super-Cab and Super-Crew vehicles without Sony System Stillwater Designs P150SC15-A

GENUINE PARTS INSTALLATION INSTRUCTIONS

GENUINE PARTS INSTALLATION INSTRUCTIONS

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

TEMPERATURE CONTROLS/ THERMOMETER/TIMERS

GE Wireless Devices Battery Replacement

Owner s Guide and Installation Manual. Vancouver Model Name , Model No. English Español

Operating Instructions

Installation instructions, accessories - Handsfree for cellular phone, system B, entry level

specializing in AIR CONDITIONING, PARTS AND SYSTEMS for your classic vehicle PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST CHEVROLET PICKUP

Instructions for: TTW 1 Universal Service Replacement Blower Kit P/N

MODEL E-AF. Drain Cleaning Machine. Operator s Manual

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

Trouble shooting for fiber Units only

PERFECT FIT SERIES IN-DASH HEAT/ COOL/ DEFROST 1967 CHEVROLET IMPALA

Arctic Leash Instruction Manual Alaskan Products Company LLC.

EXPLORE 4-Leg Teaming Table with Screen Share Assembly Instructions

430 Power/Electronics Replacement

JANUS INTERNATIONAL CORPORATION INSTALLATION INSTRUCTIONS Pantheon Mini Operator

CONTENTS TOOLS REQUIRED: Ratchet 13mm Socket 10mm Socket Phillips Screwdriver Pliers Panel Removal Tool. Amp Installation

Step 1. Item 6. Item 1

6 inch A-Arm Lift Kit WARNING: / installation instructions. will fit CLUB CAR DS. included:

Model 2300DR Installation Guide

FPU SYSTEMS OPERATION MANUAL BOH OFFICE MODULE (INCLUDING REPAIR PARTS & SPECIAL TOOL LIST) BOH FPU Field Pack/up Units CHAPTER 5

4.3-inch Back-Up Camera

IMPORTANT SAFETY RULES TO FOLLOW

D I G I T A L C L A M

Operating Instructions

LS-1 Series Tungsten Halogen Light Sources Installation and Operation Instructions

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Fading Red Tones on Color LaserJet 2600s

5800 Temperature Sensor Cable Assembly

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

Original Assembly Guide

User Manual. Instructions for installing the Sure Stitch on the Next Generation Quilting Frame. Parts Included:

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Inch PowerVent LED Indicator Explanations & Troubleshooting Table

1. SAFETY RULES. 8. Avoid placing objects in the path of the blades.

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

POWER LOCK KIT GENERAL INSTALLATION -J04427 REV Kit Number. Models. Additional Parts Required. Kit Contents

Carpet Washer. vax.co.uk VRS5W. Vax Careline: (UK) (ROI) Vax model number: Version 1.0

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Installing Your 960 or 980 Server into a Rackmount Cabinet

Left Hand Limit Switch. Housing. Left Hand. Connections. Motor Connector BROWN PURPLE GRAY BLACK DARK BLUE BLACK BROWN BROWN LIGHT BLUE.

OWNER S GUIDE OPERATION & INSTALLATION

POWER WAVE 455M/STT & (CE)

PORTABLE PA SYSTEM #1 LAST UPDATED: FEBRUARY 2011

Installation Instructions

WIRELESS REMOTE ASSEMBLY, 24VDC, 1 TRANS,1 REC

DN1600 MEGA SPIN Installation Guide INNOVATIVE CONCEPTS IN ENTERTAINMENT INC MAIN STREET, CLARENCE, NY SERVICE: FAX:

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

UNIVERSAL LUMBAR INSTALLATION INSTRUCTIONS

Before installation it is important to know what parts you have and what the capabilities of these parts are.

Fleck Service Manual INSTALLATION AND START-UP PROCEDURE TABLE OF CONTENTS JOB SPECIFICATION SHEET

Replacing Redundant AC Power Supplies in an EX4500 Ethernet Switch Without Disrupting Service

Quickie Rhapsody Service Manual

SC 7000 and SC 9000XL Patient Monitors SC 9000XL Monitor 12in (30.5cm) Display Service Manual Supplement Two

Rollator Cane and Brake Replacement SAFETY SUMMARY (CONTINUED)

Instruction Manual. Fun Pop 8oz. Popper


Rack installation instructions

Installation Instructions For Slider Casement Air Conditioners

Mazda CX

WE-350 Series ¼ Turn Electric Actuator

Manual for GlobePharma Mini-Press II Rotary Tablet Press

VOYAGER 570G. 744A Sprayer Control

Digi-Motor Installation Guide

Transcription:

PARTS & SERVICE MANUAL FOR THE CORNER WALL MOUNT FIREPLACE MODEL NUMBER: EWMC-CC-SS

TABLE OF CONTENTS OPERATION PAGE 1 PARTS LIST DRAWING PAGE 3 PARTS LIST PAGE 4 WIRING DIAGRAM PAGE 5 LIGHT BULB REPLACEMENT PAGE 6 MAIN ON/OFF SWITCH REPLACEMENT PAGE 7 MANUAL SELECTION SWITCH REPLACEMENT PAGE 8 THERMOSTAT CONTROL REPLACEMENT PAGE 9 FLAME MOTOR/FLAME ROD REPLACEMENT PAGE 10 HEATER ASSEMBLY REPLACEMENT PAGE 12 CIRCUIT BOARD REPLACEMENT PAGE 14 POWER CORD REPLACEMENT PAGE 16 MIRROR REPLACEMENT PAGE 18

OPERATION MANUAL CONTROLS The controls are located inside the door panel on the lower right hand side of the corner wall mounted electric fireplace. (FIGURE 1) A. MAIN POWER SWITCH The MAIN on/off switch supplies power to the circuit board. When the Main ON/OFF switch is switched to the ON position the Level 1 indictor light will flash. C FIGURE 1 FIGURE 2 Manual Selection Switch Main Power Switch B A Level 3 Indicator Level 2 Indicator Level 1 Indicator B. MANUAL SELECTION SWITCH Pressing the left side of the switch activates the following functions: 1. Pressing once on the MANUAL SELECTION SWITCH activates the Level 1 function. Level 1: The flame effect is turned on and the first red indicator light is activated. 2. Pressing twice on the MANUAL SELECTION SWITCH activates the Level 2 function. Level 2: The flame effect remains on, the heater is activated to the low setting, and the first and second red indicator lights are activated. 3. Pressing three times on the MAIN SELECTION SWITCH activates the Level 3 function. Level 3: The flame effect remains on, the heater is set to the high heat setting, and all three red indicator lights are activated. Pressing the right side of the switch once will turn the unit OFF. NOTE: The blower speed does not change when switching from low heat to high heat. C. HEATER THERMOSTAT CONTROL To adjust the temperature to your individual requirements, turn the thermostat control clockwise all the way to turn on the heater. When the room reaches the desired temperature, turn the thermostat knob counter clockwise until you hear a click. Leave in this position to maintain the room temperature at this setting. For additional heat, turn clockwise until you hear the click again and the heater will turn on. RESETTING THE TEMPERATURE CUTOUT SWITCH Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset. It can be reset by switching the MAIN ON/OFF SWITCH to OFF and waiting 5 minutes before switching the unit back on. 1

FIGURE 3 Frequency Code REMOTE CONTROL The corner wall mounted electric fireplace is supplied with a radio frequency remote control. This remote control has a range of approximately 50 feet (15.25m), it does not have to be pointed at the fireplace and can pass through most obstacles (including walls). It is supplied with one of 243 independent frequencies to prevent interference with other units. The frequency designation is indicated on the back of the transmitter (FIGURE 3). Remote Control Initialization This procedure is required every time there is a loss of power to the remote control in the fireplace. (i.e. power failure, breaker tripped, main power switch is turned off) 1. Ensure that the unit is plugged in wall outlet and that power is supplied through the main service panel. 2. Locate manual controls refer to FIGURE 4. 3. Activate main power switch, ( position is ON, position is OFF ) red indicator light 1 will flash (FIGURE 5). 4. Press and hold the MANUAL SELECTION SWITCH marked for five seconds. The second red indicator light will flash. 5. Press the ON button located on the remote control transmitter (FIGURE 3). This will synchronize the remote control transmitter and receiver. Remote Control Usage The remote control operates the fireplace levels sequentially. The level is increased every time the ON button on the transmitter is pressed. The fireplace can be turned off at any point by pressing the OFF button on the remote control transmitter. Level 1: The flame effect is turned on and the first red indicator light is activated. Level 2: The flame effect remains on, the heater is activated to the low heat setting, and the first and second red indicator lights are activated. Level 3: The flame effect remains on, the heater is set to the high heat setting, and all three red indicator lights are activated. NOTE: The blower speed does not change when switching from low heat to high heat. Manual Selection Switch Main Power Switch B C FIGURE 4 A 2 Level 3 Indicator Level 2 Indicator Level 1 Indicator FIGURE 5

18 2 15 1 16 8 17 12 5 14 6 7 13 11 10 4 3 9 3

REPLACEMENT PARTS CORNER WALL MOUNT FIREPLACE MOD. LEVEL NONE REPLACEMENT PART 1. LOGSET ASSEMBLY 0439040100RP 2. TOP ASSEMBLY 1106860183RP 3. BASE ASSEMBLY 1106890183RP 4. HEATER ASSEMBLY 2000230100RP 5. THERMOSTAT 2300150100RP* 6. MANUAL SELECTION SWITCH 2800070500RP 7. MAIN POWER SWITCH 2800070700RP 8. WIRE ASSY LAMPHOLDER 2500170100RP 9. REMOTE CONTROL 3000200100RP 10. CIRCUIT BOARD 3000200800RP 11. CORD SET 4100010100RP 12. REFLECTOR ASSEMBLY 5900080600RP 13. FLICKER MOTOR 2000140300RP 14. FRONT GLASS 5900460100RP 15. MIRROR 5900470100RP 16. THERMOSTAT KNOB 8800000300RP 17. LATCH DOOR ASSEMBLY 8800520100RP 18. WALL BRACKET HARDWARE KIT 1010950100RP 4

WIRING DIAGRAM THERMOSTAT WHITE ELEMENT MOTOR BLOWER RED BLACK BLACK RL3 RL2 RL1 CIRCUIT BOARD AC120V N BLACK WHITE FLICKER MOTOR WHITE LIGHT HARNESS WHITE WHITE BLACK BLACK BLACK MARR MARR BLACK POWER CORD WHITE ROUGH GREEN BLACK BLUE RED ORANGE YELLOW WHITE SMOOTH I 0 MAIN SWITCH HEATER SWITCH I 0 II LEDs 5

Light bulbs need to be replaced when you notice a dark section of the flame. There are two bulbs under the log set which generate the flames and embers. It is a good idea to replace all of the light bulbs at one time if they are close to the end of their rated life. Group replacement will reduce the number of times you need to open the unit to replace the light bulbs. TO REPLACE LIGHT BULBS 1. Unplug the unit from the outlet. 2. Open latched door. 3. Remove the 3 mounting bracket screws. 4. Set aside mounting bracket. 5. Remove 2 log set screws. 6. Set log set assembly aside. MOUNTING BRACKET LOGSET 7. Unscrew the bulb(s) counter clockwise. 8. Insert new bulb(s) screwing clockwise. 9. Assemble in the reverse order as above. NOTE: When placing log set back into unit ensure the log set sits in between the 2 vertical mounting flanges. Quantity 2 clear chandelier or candelabra bulbs with an E-12 (small) socket base, 60 watt rating. Example GE 60BC or Philips 60CTC CAUTION DO NOT EXCEED 60 WATTS PER BULB 6

TO REPLACE THE MAIN POWER SWITCH 1. Open latched door. 2. Remove the 3 mounting bracket screws and set aside mounting bracket. 3. Remove the 2 log set screws and remove the log set. 4. Locate the Main on/off switch and disconnect the wiring connections noting their original locations. 5. Depress the retainer clips on the rear of the switch and push the switch out of the log support bracket. 6. Properly orientate the new switch and connect all of the wiring connections. 7. Reassemble in the reverse order as above. NOTE: When placing log set back into unit ensure the log sits in between the 2 vertical mounting flanges. MOUNTING BRACKET LOGSET MAIN POWER SWITCH 7

TO REPLACE THE MANUAL SELECTION SWITCH 1. Open latched door. 2. Remove the 3 mounting bracket screws and set aside mounting bracket. 3. Remove the 2 log set screws and remove the log set. 4. Locate the manual selection switch and depress the retainer clips on the rear of the switch and push the switch out of the log support bracket. 5. Disconnect the wiring connections noting their original locations. 6. Properly orientate the new switch and connect all of the wiring connections. 7. Reassemble in the reverse order as above. NOTE: When placing log set back into unit ensure the log sits in between the 2 vertical mounting flanges. MOUNTING BRACKET LOGSET MANUAL SELECTION SWITCH 8

TO REPLACE THE THERMOSTAT CONTROL 1. Remove unit from corner and lay unit on its side. 2. Open latched door. 3. Remove the 3 mounting bracket screws and set aside mounting bracket. 4. Remove the 2 log set screws and remove the log set. 5. Locate the thermostat control switch and pull off the thermostat control knob to expose the mounting screws. 6. Remove the mounting screws. 7. Disconnect the wiring connections noting their original locations and remove the thermostat control switch. 8. Properly orientate the new thermostat control switch and connect all of the wiring connections. 9. Reassemble in the reverse order as above. NOTE: When placing log set back into unit ensure the log sits in between the 2 vertical mounting flanges. THERMOSTAT MOUNTING BRACKET LOGSET 9

TO REPLACE THE FLAME MOTOR/FLAME ROD 1. Open latched door. 2. Remove the 3 mounting bracket screws and set aside mounting bracket. 3. Remove the 2 log set screws and remove the log set. 4. Remove the wall mounted unit from corner and lay unit on its side. 5. Remove 4 screws from bottom heater pan and remove 2 screws from the front face of the heater pan. NOTE: Front face of bottom heater pan is located inside unit behind the latched door. 6. Disconnect the 3 heater assembly wires going to the circuit board and the thermostat. 7. Set aside bottom heater pan assembly. 8. Remove the 4 screws along the inner edge of the top heater pan and separate the top heater pan assembly from the light box assembly. NOTE: It may be necessary to remove the cord wire from the main on/off switch and the thermostat wire from the thermostat control in order to fully separate the heater pan top from the light box assembly. 9. Locate the flame motor and flame rod assembly and remove the wiring clips and connections noting their original locations. 10. Remove the 2 mounting bracket screws on the flame motor and pull the assembly partially out of the light box. NOTE: When removing the flame motor some damage may occur to the flame rod. If flame rod is damaged replace to insure proper operation. 11. To remove the flame rod attach needle nose pliers to the spring on the motor shaft and pull while rotating in the opposite direction of the spring winding. 12. Properly orientate the new flame motor and connect all of the wiring clips and connections. 10

TO REPLACE THE FLAME MOTOR/FLAME ROD WARNING: Ensure wires do not come in contact with moving parts by securing wires in wiring tie wraps. NOTE: When securing the bottom heater pan assembly to the top heater pan ensure that the 3 heater assembly wires are clear of the blower wheel. Additional wiring tie wraps may be required. 13. Reassemble in the reverse order as above. NOTE: When placing log set back into unit ensure the log sits in between the 2 vertical mounting flanges. LOGSET LIGHT BOX ASSEMBLY MOUNTING BRACKET FLAME ROD FLAME MOTOR TOP HEATER PAN BOTTOM HEATER PAN 11

TO REPLACE THE HEATER ASSEMBLY 1. Remove the wall mounted unit from corner and lay unit on its side. 2. Open latched door. 3. Remove the 3 mounting bracket screws and set aside mounting bracket. 4. Remove 4 screws from bottom heater pan and remove 2 screws from the front face of the heater pan. NOTE: Front face of heater pan is located inside unit behind the latched door. 5. Disconnect the 3 heater assembly wires going to the circuit board and the thermostat. 6. Remove 4 screws from bottom heater pan and remove heater assembly from bottom heater pan. 7. Remove 4 screws from heater plate. 8. Disconnect heater assembly wires noting their original locations. 9. Properly orientate the new heater assembly and connect all of the wiring connections. WARNING: Ensure wires do not come in contact with moving parts by securing wires in wiring tie wraps. NOTE: When securing the bottom heater pan assembly to the top heater pan ensure that the 3 heater assembly wires are clear of the blower wheel. Additional wiring tie wraps may be required. 10. Reassemble in the reverse order as above. 12

LOGSET MOUNTING BRACKET TOP HEATER PAN HEATER ASSEMBLY HEATER PLATE BOTTOM HEATER PAN 13

TO REPLACE THE CIRCUIT BOARD 1. Remove wall mounted unit from corner and lay unit on its side. 2. Open latched door. 3. Remove the 3 mounting bracket screws and set aside mounting bracket. 4. Remove 4 screws from bottom heater pan and remove 2 screws from the front face of the heater pan. NOTE: Front face of heater pan is located inside unit behind the latched door. 5. Disconnect the 3 heater assembly wires going to the circuit board and the thermostat. 6. Remove the red indicator lights out through the bottom of the log support bracket noting their original locations. 7. Locate the manual selection switch and depress the retainer clips on the rear of the switch and push the switch out of the log support bracket. 8. Disconnect the wiring connections noting their original locations. 9. Locate the remote control circuit board mounted to the back of the top heater pan and remove the wiring connections noting their original locations. 10. Depress the ends of the four plastic mounting posts with pliers. 11. Remove the circuit board from unit. 12. Properly orientate the replacement circuit board and connect all of the wiring connections. WARNING: Ensure wires do not come in contact with moving parts by securing wires in wiring tie wraps. NOTE: When securing the bottom heater pan assembly to the top heater pan ensure that the 3 heater assembly wires are clear of the blower wheel. Additional wiring tie wraps may be required. 13. Reassemble in the reverse order as above. 14

TO REPLACE THE CIRCUIT BOARD NOTE: When installing the replacement circuit board ensure the red heat indicator lights are installed into their original mounting locations. LOGSET MOUNTING BRACKET TOP HEATER PAN CIRCUIT BOARD BOTTOM HEATER PAN 15

TO REPLACE THE POWER CORD 1. Remove wall mounted unit from corner and lay unit on its side. 2. Open latched door. 3. Remove the 3 mounting bracket screws and set aside mounting bracket. 4. Remove 4 screws from bottom heater pan and remove 2 screws from the front face of the heater pan. NOTE: Front face of heater pan is located inside unit behind the latched door. 5. Disconnect the 3 heater assembly wires going to the circuit board and the thermostat. 6. Locate and disconnect the power cord wiring connections noting their original locations. 7. With needle nose pliers grasp the power cord strain relief grommet from inside the rear of the heater pan top and push while twisting to remove. 8. Pull the power cord out through the hole in the rear of the top heater pan. 9. Install the new power cord through the hole in the rear of the top heater pan and connect all of the wiring connections in their original locations. 10. Install the power cord strain relief grommet on the replacement power cord and insert into the mounting hole in the rear of the top heater pan. WARNING: Ensure wires do not come in contact with moving parts by securing wires in wiring tie wraps. NOTE: When securing the bottom heater pan assembly to the top heater pan ensure that the 3 heater assembly wires are clear of the blower wheel. Additional wiring tie wraps may be required. 11. Reassemble in the reverse order as above. 16

TO REPLACE THE POWER CORD LOGSET MOUNTING BRACKET POWER CORD TOP HEATER PAN BOTTOM HEATER PAN 17

TO REPLACE THE MIRROR 1. Remove wall mounted unit from corner and lay unit on its side. 2. Open latched door. 3. Remove door chain bolt and nut from back panel assembly. 4. Remove top mirror bracket from back panel and set aside. 5. Remove mirror from unit and remove black rubber channels from mirror. 6. Install black rubber channels to replacement mirror. 7. Reassemble in the reverse order as above. 18