Philips MicroDose. Photon counting technology +100V. holes

Similar documents
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Digital Mammography Update: Design and Characteristics of Current Systems

The Fundamentals of MTF, Wiener Spectra, and DQE. Motivation

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

College on Medical Physics. Digital Imaging Science and Technology to Enhance Healthcare in the Developing Countries

Page: 1 of 6 Page: 1 of 6

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

2 Absorbing Solar Energy

Physics testing of image detectors

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

TOF FUNDAMENTALS TUTORIAL

EDXRF of Used Automotive Catalytic Converters

Radiographic Grid. Principles of Imaging Science II (RAD 120) Image-Forming X-Rays. Radiographic Grids

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

Radiation Detection and Measurement

CHAPTER 3: DIGITAL IMAGING IN DIAGNOSTIC RADIOLOGY. 3.1 Basic Concepts of Digital Imaging

Atomic and Nuclear Physics Laboratory (Physics 4780)

Digital radiography conquers the veterinary world

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

EDS system. CRF Oxford Instruments INCA CRF EDAX Genesis EVEX- NanoAnalysis Table top system

Introduction to Geiger Counters

Fundamentals of Cone-Beam CT Imaging

Lectures about XRF (X-Ray Fluorescence)

CONTENT SPECIFICATIONS FOR THE FLUOROSCOPY EXAMINATION

SECTION 1: REQUIREMENTS FOR CERTIFICATES OF COMPLIANCE FOR CLASSES OF RADIATION APPARATUS

Vacuum Evaporation Recap

Information about the T9 beam line and experimental facilities

PHOTOELECTRIC EFFECT AND DUAL NATURE OF MATTER AND RADIATIONS

ON-STREAM XRF ANALYSIS OF HEAVY METALS AT PPM CONCENTRATIONS

Avalanche Photodiodes: A User's Guide

Comparing Digital and Analogue X-ray Inspection for BGA, Flip Chip and CSP Analysis

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

ACCELERATORS AND MEDICAL PHYSICS 2

Quality Control of Full Field Digital Mammography Units

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Choosing a digital camera for your microscope John C. Russ, Materials Science and Engineering Dept., North Carolina State Univ.

E/M Experiment: Electrons in a Magnetic Field.

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

Solid State Detectors = Semi-Conductor based Detectors

Running head: COMPARISON OF AMORPHOUS SELENIUM AND AMORPHOUS 1

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

GAMMA-RAY SPECTRA REFERENCES

Radiography: 2D and 3D Metrics of Performance Towards Quality Index

Appendix A: Science Practices for AP Physics 1 and 2

X-RAY IMAGING Emerging Digital Technology - CMOS Detectors

INTRODUCTION. A. Purpose

Calorimetry in particle physics experiments

Diagnostic x-ray imaging relies on the attenuation of

Improving digital image quality for larger patient sizes without compromises

X- and Gamma Ray Imaging Systems based on CdTe-CMOS Detector Technology

Introduction to CCDs and CCD Data Calibration

Introduction to the Monte Carlo method

Using the Spectrophotometer

Appendix A. An Overview of Monte Carlo N-Particle Software

Fundamentals of Digital Mammography: Physics, Technology and Practical Considerations Andrew P. Smith, Ph.D.

Experiment 5. Lasers and laser mode structure

Truly digital PET imaging

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Application Note # EDS-10 Advanced light element and low energy X-ray analysis of a TiB 2 TiC SiC ceramic material using EDS spectrum imaging

Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL

Problem Set 6 UV-Vis Absorption Spectroscopy Express the following absorbances in terms of percent transmittance:

13C NMR Spectroscopy

Proton tracking for medical imaging and dosimetry

- thus, the total number of atoms per second that absorb a photon is

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

Production of X-rays and Interactions of X-rays with Matter

How To Understand Light And Color

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

GAFCHROMIC DOSIMETRY MEDIA, TYPE HD-V2

Physics 441/2: Transmission Electron Microscope

CONCEPT OF DETERMINISTIC ION IMPLANTATION AT THE NANOSCALE

CHAPTER 5 QC Test For Radiographic Equipment. Prepared by:- Kamarul Amin bin Abu Bakar School of Medical Imaging KLMUC

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

Radiation Strip Thickness Measurement Systems

1090 IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 50, NO. 4, AUGUST Intelligent Gamma-Ray Spectroscopy Using 3-D Position-Sensitive Detectors

FXA UNIT G485 Module Ultrasound. Candidates should be able to :

5.2 ASSESSMENT OF X-RAY TUBE LEAKAGE RADIATION AND X-RAY TUBE OUTPUT TOTAL FILTRATION

High Resolution Spatial Electroluminescence Imaging of Photovoltaic Modules

Signal to Noise Instrumental Excel Assignment

1. Oscilloscope is basically a graph-displaying device-it draws a graph of an electrical signal.

GE Medical Systems Training in Partnership. Module 8: IQ: Acquisition Time

Measurement of Charge-to-Mass (e/m) Ratio for the Electron

Radiographic Image Production. Radiographic Image Production. Principles of Imaging Science I (RAD 119) Film, Screens, and Cassettes

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

(Amplifying) Photo Detectors: Avalanche Photodiodes Silicon Photomultiplier

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

How to calibrate an RTD or Platinum Resistance Thermometer (PRT)

Sound absorption and acoustic surface impedance

Truly digital PET imaging

Characterizing Digital Cameras with the Photon Transfer Curve

EXPERIMENT 11 UV/VIS Spectroscopy and Spectrophotometry: Spectrophotometric Analysis of Potassium Permanganate Solutions.

ELECTRON SPIN RESONANCE Last Revised: July 2007

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Gamma and X-Ray Detection

X Ray Flourescence (XRF)

Transcription:

Philips MicroDose Photon counting technology +100V holes

Index Requirements for detectors.... 3 Available detector technologies.... 4 Photon counting technology.... 5 Detector design.... 5 Readout electronics.... 6 Noise rejection.................................... 7 Weighting of X-ray photons with different energies.... 8 Anti-scatter grids.... 9 Scanning technology and scatter rejection.... 10 System DQE.... 11 Summary of characteristics for Philips MicroDose.... 12 References.... 12 2

Requirements for detectors Of all medical X-ray applications, mammography puts the highest demands on the imaging system. As a result, mammography is the last X-ray-based imaging technology to convert from film-screen to digital detector techniques. For the image quality to be optimized and the radiation dose to be reduced, all the links in the imaging chain have to be considered; no imaging system is stronger than its weakest link. For a digital mammography system, the following requirements have to be met: High image quality High-spatial resolution is needed to visualize and characterize the small structures in breast tissue. The detector element size and spacing define the maximum spatial resolution in an image. In mammography, a spatial resolution of 50 µm to 100 µm is required. This results in a limiting spatial resolution of 10 line pairs per mm to 5 line pairs per mm respectively. High-contrast resolution is needed for differentiation of breast tissues that have very similar X-ray absorption. Wide dynamic range is important, as the image has to include information from both dense regions of glandular tissue, regions of fatty tissue, and all the way out to the skin line. Low noise facilitates accurate diagnosis. Noise reduces the contrast resolution. Absence of artifacts. Artifacts can for example be caused by electronic noise in the detector, or ghost images. No dead pixels. Dead pixels can be interpolated from neighboring pixels; this will improve the appearance of the image but not retrieve the lost information. Low radiation dose High quantum efficiency allows the detector to record every incident X-ray photon, maximizing dose efficiency of the system. Efficient rejection of scattered radiation. Scatter adds noise and reduces the contrast resolution in the image, which has to be compensated by increasing the exposure. 3

Available detector technologies Conceptually, what differentiates the different detector technologies is the number of intermediate conversion steps before a digital signal is formed. This is shown schematically in Figure 1, which indicates the stages at which the signals from individual photons are added (enclosed in green boxes). Each conversion step has the potential to deteriorate image quality. For systems that use techniques other than photon counting, the initial digital signal from the X-rays is converted into an analog signal, and after the exposure one attempts to retrieve the original digital signal through an analog-todigital converter. Decreasing number of noise sources Image acquisition cycle 1985 Time for introduction 1999 CR plates 2002 X-ray excitation of electron states Accumulation of trapped charge Conversion to light with laser beam Light conversion into electrical analog signal a-si / CCD X-ray conversion to light Light conversion to electrical charge Charge accumulation in pixel Readout of total charge in pixel a-se X-ray conversion to electrical charge Charge accumulation in pixel Readout of total charge in pixel 2003 Photon counting X-ray conversion to electrical pulse A/D conversion of signal A/D conversion of signal A/D conversion of signal Incrementation of counter if charge above threshold Digital output Digital output Digital output Digital output Figure 1 Schematic representation of different digital detector technologies for mammography. Analog steps are above the red line; digital steps are below the red line. The green boxes indicate the stages at which the signals from individual photons are added. 4

Photon counting technology X-rays are often perceived as a continuous fluid of energy. In reality this fluid consists of individual particles, so called X-ray photons, which react one-by-one in an X-ray detector. The X-rays are thus digital by nature. The Philips MicroDose detector is built to match this digital nature of X-rays. The Philips MicroDose detector increments the photon counter directly as each individual X-ray is detected. This means that there are no intermediate steps that can add noise from the detection of the photon to the pixel value in the mammogram as indicated in Figure 2. Since there is a risk in every conversion step of adding noise and losing signal, significant effort by several companies has been focused on reducing the number of conversion steps. X-ray photon MicroDose detector Photon counter The Philips MicroDose detector is a spin-off from high-energy physics research. It is an integrated result from thousands of researchers working from 1960 to the discovery of the top quark in 1996. 1 In highenergy physics, e.g. the search for the top quark, the requirements have been very high for detection efficiency and for extracting maximum information from every detected particle, such as X-ray photons. Detector Design The detector system consists of a large number of crystalline silicon strip detectors, with the strips tapered to point back to the X-ray source. Silicon has excellent electronic properties and very good energy resolution. A drawback is the relatively weak attenuation due to the low atomic number (Z=14). This is overcome by placing the strip detectors in edge-on geometry with their long axis parallel to the direction of the X-ray beam. In this way, a sufficient absorption length is created, resulting in high quantum efficiency for the full energy spectrum used in mammography. Digital signal Figure 2 Philips MicroDose photon counting detector. X-ray photons X-ray photon Figure 3 Crystalline Silicon strip detectors with edge-on geometry. 5

The X-ray interaction in the Si transfers energy to either a photo-electron or Compton electron that subsequently excites electron hole pairs. Since only 3.6 ev is required to create an electron hole pair, several thousand pairs are created for one incident X-ray photon and there is no need for further amplification. A bias voltage is applied across the Si-detector, which generates a bias field. This electrical field causes the charge cloud to be swept towards electrodes with positive voltage and the charge cloud of holes to be swept to electrodes on the opposite side. This drift induces a short electrical signal on the electrodes. The signal is transferred from the aluminum strip to the pulse-shaping electronics through wire-bonds. X-ray photons +100V electrons holes Figure 4 X-ray generates a cloud of electron-hole pairs that create a short electrical signal. Due to the large market for microelectronics that has emerged during the last 50 years, crystalline silicon is by far the purest detector material available. The existing production facilities are huge and standard batch processing of excellent quality and high yield are routine in a reliable production process that has been optimized over the last 4-5 decades. Readout Electronics The custom-designed ASIC (Application Specific Integrated Circuit) contains pre-amplifier, shaper, comparator and a digital counter. All channels in the ASIC work in parallel. The shaper creates a signal around a few hundred nanoseconds in duration. The comparator discriminates pulses above a certain threshold level from the detector noise and counts these pulses. The counter has 15 bits to enable wide dynamic range. Each ASIC read-out channel can handle count rates up to 2 MHz, allowing acquisition of images with sufficient statistics in a few seconds. The number of counted photons in each channel is accumulated during a single sampling interval before being sent to the workstation for image reconstruction and display. 6

Noise rejection The pulses created in the Philips MicroDose detector by the incident photons are easily detected, since the pulse height (5000 electrons) is an order of magnitude higher than the electronic noise in the detector (200 electrons rms). Thus the detector counts the number of peak pulses and nothing else. With no conversion steps from X-ray photons to a digital signal; Swank noise, electronic noise and noise from the quantification of the electrical signal from the detector can be removed almost entirely. If all external noise sources are eliminated, the system is said to work at the quantum limit. This is the ultimate limit for information provided by the laws of physics. Ideally the X-ray photons in all pixels should be distributed according to the mathematical Poisson distribution. These fluctuations are sometimes referred to as quantum mottle or (wrongly) as quantum noise. For film-screen systems and scintillator-based digital systems, Swank noise can be a serious cause of image degradation. This noise is introduced by the statistical variation of released light after the conversion of the photon. 2 Hence, two photons of the same energy can have different responses in the detector, which translates to an overall uncertainty in the integrated signal. This effect is to some extent present in integrating detectors such as amorphous silicon detectors. The absence of Swank noise and the significant removal of electronic noise is a major advantage of the photon counting technology. Energy Lowest photon energy Threshold Electronic noise X-ray photon X-ray photon X-ray photon Time Figure 5 The threshold is set to an optimum level for the energy of the X-ray photons used in mammography, which results in a quantum efficiency of more than 90%. 7

Weighting of X-ray photons with different energies To date, all mammography systems available on the market, except for the Philips MicroDose system, have been integrating systems, i.e. the signal is formed by a sum of liberated electric charge or light from X-ray photon interactions. The amount of charge, or light, is proportional to the photon energy. Therefore, with an integrating technique a higher energy photon will gain a higher statistical weight compared to less energetic photons. However, the attenuation in the breast, as well as the contrast, is strongly dependent on energy. It is the low-energy photons that carry more contrast information and should be given a higher statistical weight. This subject was first discussed two decades ago 3 but has not generated much attention. The contrast is proportional to the linear attenuation coefficient of the object being imaged. The subject contrast is roughly proportional to E-3 (photon energy), practically independent of tissue type and the size of the abnormality being detected. For integrating systems the signal is proportional to energy, and hence the statistical weight function is incorrect by four powers. Contrast 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 5 cm thick breast 0.1 mm micro-calcification 5 mm mass 0 10 15 20 25 30 35 E (kev) Figure 6 Low energy photons carry more contrast information. A photon counting system with the same weight for all photons is an improvement over current integration, but does not provide the level of contrast sensitivity afforded by optimal energy weighting. The numerical example to the right is exaggerated to demonstrate the principle. Detailed calculations show that a photon counting system improves the dose efficiency by more than 10%. 4 8

Anti-scatter grids The conventional way of reducing the scatter-to-primary (S/P) ratio is to insert a Bucky grid between the breast and the detector. The anti-scatter grids are comprised of high aspect-ratio lamellae that absorb the rays that have been scattered at angles beyond acceptance. Depending on the geometry, discrimination between scattered photons and primary photons is more or less efficient. However, for mammography energies, the grids will also remove a significant fraction of the direct photons and are mechanically very difficult to manufacture. The Bucky factor expresses the increase in patient dosage that is needed to maintain the exposure to the detector when a grid is inserted. It is typically 2-3, and contrast improvements exceeding 80% can be achieved. 5 The grid usually moves during the exposure to prevent it from appearing in the image, but there are also high strip density, stationary grids. Grids are usually linear, unable to reject photons scattered along the absorbing strips. In recent years, high transmission cellular grids with air interspaces have exhibited improved performance and become more widespread. However, studies show that the use of a grid in conventional mammography provides far from ideal scatter rejection. To quantify, we introduce the scatter DQE as the ratio of squared SNR s between actual scatter rejection and perfect scatter rejection. This can be calculated through: Scattered radiation Radiation scattered in the breast is a common source of image degradation in mammography. Scattered radiation will reduce the contrast and increase the noise, which must be compensated by increasing the dose to the patient. This effect is particularly pronounced for thick breasts. It is quantified by the (S/P), which is ideally zero but can be of the order of unity in practice. T p S R E = 1 +S / P where Tp is the transmission of primary photons. 6 Using values from Ref., 7 we find that SRE is in the range 0.5 0.6 for a standard grid. 9

Scanning technology and scatter rejection Achieving efficient scatter rejection is much easier for a scanning system in which a small detector is moved across the object to acquire the full-field image. The main principle is, the smaller the detector used, the lower the risk that a scattered photon will interact. That means no grid is needed in a scanning system and thus a major mechanical simplification is attained since the mechanical construction to achieve a linear translation of a slit is much simpler compared to the complicated mechanics of a Bucky. Systems are divided into slot and slit scanning systems. For the former, a 2D detector is used, while the latter has a linear detector covering only one pixel row. A multi-slit system has several of these linear slits to create better photon economy, i.e. using a larger portion of the output from the X-ray tube. In this way, the image acquisition time and/or tube load can be reduced. The load for the X-ray tube will be higher for a scanning system and this is compensated for by increasing the diameter of the anode disc from 3 inches (standard in mammography) to 4 inches, which is a minor modification of the relatively simple X-ray tubes used in mammography. X-ray tube Collimator 1 Object Collimator 2 Detector Moving parts Scan motion Figure 7 Multi-slit scanning technology used in Philips MicroDose. Philips MicroDose is of the multi-slit type. Photons that are not initially directed towards the detector are removed from the beam by a pre-collimator. These photons are useless and would otherwise only contribute to patient dose. The post-collimator absorbs the photons scattered in the breast and not directed towards the detector. During the continuous scan motion, the detector is read every 2 ms. Besides the cost advantages of using a smaller detector, the main advantage of this technique is the efficient rejection of scattered radiation. The S/P-ratio is only about 3% without any loss of primary radiation. 8 This inherent scatter rejection is another reason why Philips MicroDose can reduce the radiation dose significantly compared to that used on conventional systems. 10

System DQE Scatter DQE Scatter DQE shows how well the system rejects scattered radiation from the breast. Detection of scattered X-rays decreases the contrast and degrades image quality. Conventional Bucky grids are far from perfect and have a scatter DQE of roughly 50%. The scanning multi-slit geometry of Philips MicroDose provides an excellent scatter rejection and a scatter DQE of 96%. 8 Detector DQE Detector DQE is the conventional measure of how a regular pattern is imaged by the system and especially shows how this is degraded by noise in the system. Degradation by scattered radiation is not included here. Neither does this measure show how contrasts in actual breast tissue are imaged. 9 Energy weighting Energy weighting describes how the information in the X-ray beam is captured by the detector. The low energy photons contain more information than the high energy ones, and should thus be weighted higher by the detector. Energy-integrating systems do the opposite, while photon counting detectors put equal weight on each photon. The energy weighting factor shows how much efficiency is lost compared to a photon counting system. 4 Traditionally, X-ray detectors have been compared through the detective quantum efficiency (DQE). With the advent of new technologies, such as photon counting and multi-slit-scanning, detector DQE is an inadequate measure of the complete imaging system s performance. A better figure-of-merit is the system DQE, in which several additional properties have been taken into account. The system DQE is composed of three factors: Detector DQE Scatter DQE Energy weighting 11

Summary of characteristics for Philips MicroDose Matches the digital nature of X-rays; each X-ray is processed individually and external noise is almost entirely eliminated High Quantum Efficiency Almost perfect scatter rejection 50 µm pixel size Field of view 24 x 26 cm Scan time 3-15 seconds Tungsten anode, 0.5 mm Al filter All radiation hits active detector area, no radiation spill Maximum count rate 2 MHz per pixel and no ghost images No dead pixels References 1 Abe, F. et al., 1994. Evidence for Top Quark Production in pp Collisions at sqrt(s) = 1.8 TeV. Fermilab-PUB-94/116-E. May 16, pp.1-19 2 Swank, R., 1973. Absorption and noise in X-ray phosphors. Journal of Applied Physics, 44, pp.4199 203. 3 Tapiovaara, M., Wagner, R., 1985. SNR and DQE analysis of broad spectrum X-ray imaging. Physics in Medicine and Biology, 30, pp.519 29. 4 Cahn, R.N., Cederström, B., Danielsson, M., Hall, A., Lundqvist, M., Nygrenn, D., 1999. Detective Quantum Efficiency dependence on X-ray energy weighting in Mammography. Medical Physics, 26(12), pp.2680-3. 5 Rezentes, P., de Almeida, A., Barnes, G., 1999. Mammography grid performance. Radiology, 210(1), pp. 227 32. 6 Wagner, R., Barnes, G.T., Askins, B.S., 1980. Effect of reduced scatter on radiographic information content and patient exposure: A quantitative demonstration. Medical Physics, 7(1), pp.13-8. 7 Dance, D.R., Persliden, J., Carlson, G.A., 1992. Calculation of dose and contrast for two mammography grids. Physics in Medicine and Biology, 37(1), pp.235-48. 8 Åslund, M., Cederström, B., Lundqvist, M., Danielsson, M., 2006. Scatter rejection in multi-slit digital Mammography. Medical Physics, 33(4), pp.933-40. 9 Dobbins III, J.T., 2000. Image Quality Metrics for Digital Systems. In: J. Beutel, H.L. Kundel, R.L. van Metter, ed. 2000. Handbook of Medical Imaging, Volume 1. Physics and Psychophysics. Bellingham WA, USA: SPIE Press. pp.161-219 Please visit www.philips.com/microdose 2011 Koninklijke Philips Electronics N.V. All rights are reserved. Philips Healthcare reserves the right to make changes in specifications and/ or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Philips Healthcare is part of Royal Philips Electronics www.philips.com/healthcare healthcare@philips.com Printed in The Netherlands 4522 962 79741 * OCT 2011