Advanced Amperometic Oxygen Sensors

Similar documents
VISIFERM DO. Optical Oxygen Sensors with Integrated Transmitter THE MEASURE OF EXCELLENCE

Dissolved Oxygen Sensors

Stainless Steel Dissolved Oxygen Electrodes

OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

ORBISPHERE M1100: CUSTOMER SUCCESS STORY - CARLSBERG

DISSOLVED OXYGEN PROBE

Trace Dissolved Oxygen Sensor

DissolvedOxygenMonitor

ABB PSPS Erich Steinmann; Generator control-2013

Resolution selectable from 0.01 and ph. Range ph. Accuracy ± ph

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors

NEULOG HEART RATE AND PULSE LOGGER SENSOR GUIDE

For additional information, please visit our website at

Inferred ph in Steam Plant Water Chemistry Monitoring

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

Hand-held thermometer Model CTH7000

EDI Distributor Control Interface Wiring and Setup Instructions

Milwaukee USER MANUAL

OxyGuard. Dissolved Oxygen Probe

Conductivity and TDS Meters

OEM Optical Competences. Solutions for Optical OEM Applications in Liquid Analysis.

Ion Selective Electrodes

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

The photoionization detector (PID) utilizes ultraviolet

User Guide Dissolved Oxygen Probes

User's Guide. ExStik DO600. Dissolved Oxygen Meter RECALL. Dissolved Oxygen DO600

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

Digital and Analog I/O

Application Requirement

API Marine. BMS Presentation. Ballast Measurement Systems

Direct Measurement Method Method to 20.0 mg/l (or 0 to 200% saturation) O 2 Clark-type Amperometric Sensor

Chicago Process Solution Summit: Liquid Analysis Made Easy

DDX 7000 & Digital Partial Discharge Detectors FEATURES APPLICATIONS

Experiment 5. Lasers and laser mode structure

Vacuum drying oven for non-flammable solvents

PROFIBUS/PROFINET System design

Gas sensors for greenhouse measurements

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Digital input modules

Compact ph Measuring Instruments

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

Product Information Fire alarm panel 8000 C

INTREPID Perimeter Intrusion Detection System

Perimeter Security System

How Sensors Work. How Oxygen, Electrochemical Toxic, and Metal Oxide Semiconductor Sensors Work *

Galvanic Parts Per Million Dissolved Oxygen Systems

Relative Humidity Sensors, Transmitters and Calibration Products Relative Humidity Measurement and Calibration

LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer

System Wiring Design Guide

Transmitter Interface Program

Dew-Point Measurement Solutions

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

Operation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family

JUMO BlackLine CR-GT/-EC/-GS Conductive 2-Electrode Conductivity Sensor

Enzyme Action: Testing Catalase Activity

Introduction to PROFIBUS and PROFINET

PortaSens ll G AS DETECTOR

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

Physical Specifications (Custom design available.)

Experiment HE-6: Breath by Breath Measurement of Respiratory Exchange Ratio (RER)

Product Information Sheet UH36 Hi Pot Tester

Modular I/O System Analog and Digital Interface Modules

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry

6 H2O + 6 CO 2 (g) + energy

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Spectrophotometry and the Beer-Lambert Law: An Important Analytical Technique in Chemistry

Gas Custody Transfer Calibration

Why a torque measuring system?

Austin Peay State University Department of Chemistry Chem The Use of the Spectrophotometer and Beer's Law

Continuous Monitoring of Flue and Combustible or Hazardous Gases and Vapors

Digital inductive conductivity transmitter

Atlas Copco. On-site Industrial Gases Nitrogen & Oxygen Generators

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

LED DIMMING A HELPFUL GUIDE...

white paper reviews why the chlor-alkali process is so damaging to ph electrodes and discusses a sensor design that has

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Introducing: BioXpert. Supervisory Control and Data Acquisition Software

Lead Testing and On Site Calibration for Water Testing Detection Range: 2 100ppb

Engineering Specifications XNX Universal Transmitter

PROCESS AUTOMATION. OPERATING AND MONITORING IN HAzARDOUS AREAS AND INDUSTRIAL ENVIRONMENTS PRODUCT OVERVIEW

XBee USB Adapter Board (#32400)

MINIMAT-EC-Servo Screwdriver Spindles

G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method

PCS0100en Persy Control Services B.V. Netherlands

Ozone Sensor. Model 499A OZ CAUTION CAUTION. Instruction Sheet PN 51A-499AOZ/rev.F January 2007

RAEGuard EC FGM-13XX

Contamination Control and Environmental Monitoring Systems

the importance of ph in water purification the importance of ph in water purification Water Purification Systems UK

Transcription:

Advanced Amperometic Oxygen Sensors Replacement Membranes and Polarization Modules OXYGOLD Membrane Kit 3 OXYGOLD membranes, spare o-ring, pipette. Electrolyte must be ordered separately. OXYFERM Membrane Kit 3 membrane bodies, Oxylyte, pipette, spare o-ring, polishing strip Membrane Kit CIP As above, but with a special membrane for intensive CIP cleaning Membrane Kit FDA FDA membrane material and rounded design to prevent accumulation of gas bubbles Polarization modules These prepare replacement sensors not connected to an amplifier for immediate use OXYGOLD G Dissolved oxygen sensor for general use in trace measurement : 1 ppb to saturation or 0-130 C, max. 1 bar TC: NTC kohm power plants, chemical, pharmaceutical and semiconductor industries temperatures, high pressures, during sterilization and CIP user certificate VP plug OXYGOLD B Dissolved oxygen sensor for measurements in media containing acidic gases CO, in beer : 8 ppb to saturation or 0-100 C, max. 1 bar TC: NTC kohm to C Cola, fruit-juice, sparkling wine and special chemical processes user market from air to pure C certificate voltages in calibration and measurement. So you don t get false measurement values when measuring in samples like beer. Name Order No. Name Order No. Name Order No. OXYFERM MEMBRANE KIT MEMBRANE KIT CIP MEMBRANE KIT FDA POLARIZATION MODULE T for OXYFERM /~FDA/~XL POLARIZATION MODULE G for OXYFERM VP, OXYGOLD G POLARIZATION MODULE B for OXYGOLD B OXYGOLD OXYLYTE G 50 ml OXYGOLD OXYLYTE B 50 ml OXYFERM OXYLYTE 50 ml OXYLYTE USD 50 ml 37 135 37 13 37 16 37 140 37 370 37 350 37 360 37 139 37 138 37 118 37 136 OXYGOLD G 10 OXYGOLD G 5 OXYLYTE G 50 ml POLARIZATION MODULE G Replacement Cathode OxyGold G HYGIENIC SOCKET (page 38) RETRACTEX (page 46) Connecting cable (page 37) 37 395 37 396 37 135 37 139 37 350 37 47 OXYGOLD B 10 OXYGOLD B 5 OXYLYTE B 50 ml POLARIZATION MODULE B Replacement Cathode OxyGold B HYGIENIC SOCKET (page 38) RETRACTEX (page 46) Connecting cable (page 37) 37 180 37 185 37 135 37 138 37 360 37 437 31

HAMILTON VISIFERM DO Sensors Optical oxygen measurement with built-in analyzer, in 1 mm format With VISIFERM DO, HAMILTON is the first company to offer self-contained oxygen measurement in the popular 1 mm format similar to standard process ph electrodes. Combined in the VISIFERM sensor shaft are: high-temperature-resistant optical electronics, microprocessor, 4 to 0 ma analog output, digital RS 485 interface with ModBus protocol, and ECS interface. ECS stands for Electro-Chemical Sensor. Use of the 4 to 0 ma analog output or the digital RS 485 interface (both integrated into the 1 mm shaft) makes an external measurement amplifier unnecessary, allowing measurement signals to be fed directly into a process control system. VISIFERM DO measurement principles The unique design of VISIFERM DO enables HAMILTON to monitor the status of the sensor s blue LED using one of the photodiodes. The other photodiode with the red filter measures the oxygendependent red light generated on the luminophore through luminescence (fluorescence) caused after exitation by the blue light. Electrons are excited to a higher energy level, and return to their original level after emission of red light. Absorption of blue light Exited state Emission of light When the luminophore comes into contact with elemental oxygen, the molecules absorb the increased energy, thus preventing the emission of red light. Therefore, the amount of Oxygen is inversely proportional to the intensity and duration of the luminescence. Exited state Energy transfer by collision Absorption of blue light No light emission -channel optics for optimal function and diagnostics HAMILTON chose a mechanically- and thermally-stable symmetrical design directly in the sensor casing. O O O O O Sensor shaft Two identical light detectors Color filters Blue LED Robust carrier Luminophore FDA silicone Process media with dissolved oxygen High precision measuremet of the optical phase shift between the blue and red light pulses provides accurate indication of oxygen concentration. The difference in intensity is analyzed by the instrument s self-monitoring system to pinpoint photobleaching (bleaching of the luminophore). Measurement, calculation, and output of the measured value occur entirely inside the sensor. 80 Phase shift 0 Air saturation Notice that VISIFERM DO sensors measure the partial pressure of oxygen (p ) just like classical sensors. This concentration in mg/l, ppm, or even as ppb. Application fields VISIFERM DO sensors have been evaluated in a variety of applications: Biotechnology. VISIFERM DO sensors are developed to be steamsterilized, autoclaved and cleaned in place (CIP) without difficulty. Therefore VISIFERM DO is ideal for use in fermenters and similar demanding applications. Waste water treatment. Ground water monitoring. River water monitoring. Breweries. With the standard design form of a classical 1 mm sensor with PG 13.5 thread VISIFERM DO can be used with existing armatures. Comparison of VISIFERM DO (top) and a classical DO sensor (bottom) 3

Optical, Sterilizable Oxygen Sensor Operational reliability is paramount A comparison with classical measurement technology The most common malfunction of classical Clark Cells is caused by damage to the mechanically sensitive oxygen membrane. VISIFERM DO does not suffer from this problem, because it has no fragile membrane and no electrol yte; instead, it has a robust, solid Sensor Cap. Cable transmission of very low Clark Cell currents to amplifiers represents a further problem. Measurement results of VISIFERM DO can be sent from the sensor as robust 4 to 0 ma analog, or digital signals. Both are far more tolerant of difficult process conditions than the sensitive (na) signals of a classical electrochemical dissolved oxygen sensor. Blue light: A decisive part of the VISIFERM measurement principle. Technology that sets new standards Intelligent Sensor VISIFERM DO gives the designation intelligent sensor new meaning, with respect to its integrated funcionality: Precise measurement optics, stable up to 130 C, built into a 1 mm shaft. Easily replaceable Sensor Cap containing the sensing element. Monitoring of all sensor functions, status of the replaceable Sensor Cap. Configurable using the RS 485 interface with notebook, PC or by using the Modbus RTU connection from the process control system. Saving of all process relevant information: Sensor and calibration data, operating hours, cleaning and sterilization cycles, etc. Compatible with new ARC System products: - ARC View Handheld - ARC Wi Sensor Adapter - ARC Sensor Configurator VISIFERM with different shaft lengths. 33

VISIFERM DO All-in-One Sensor Three options to connect Fieldbus: VISIFERM DO offers the widelyused Modbus RTU interface, enabling up to 3 sensors or other devices to be wired onto the same bus, in a highly cost-effective installation. The Modbus interface offers users comprehensive information, including input from the sensor s diagnostics and health indicator. Numerous gateways are available to interface Modbus to Foundation Fieldbus, Profibus, and others. Robust 4 to 0 ma current: Connects VISIFERM DO directly to a PLC or PCS, with no transmitter. ECS: The Electro-Chemical Sensor interface connects VISIFERM DO to traditional transmitters/analyzers for electrochemical oxygen sensors. ECS option can be selected using the ARC Sensor Configurator. Safe trace measurements Trace measurements with classical sensors are not considered particularly accurate or safe, since in the absence of oxygen, no molecules are reduced, so no electrical current can flow. The same happens when a cable breaks. VISIFERM DO does not suffer from these problems because it is at low oxygen concentrations that the greatest amount of red light is emitted, and the measured phase shift is at its greatest. Operational reliability and simple maintenance User friendliness is a critical quality in a sensor. Every procedure made redundant signifies an increase in operational reliability. Achieving simple maintenance is of particular value. When a problem occurs during the night shift, with only limited personnel available to perform maintenance and calibration, VISIFERM DO really helps. All you have to replace is a Sensor Cap, and it is as quick and easy as opening and closing a bottle of soda: the Sensor Cap twists off, and the new one twists on. Job done. You need only perform calibration in air, although ideally, also in nitrogen or carbon dioxide. The sensor can be conveniently calibrated in the laboratory and remains calibrated for the next process run. 34

Optical, Sterilizable Oxygen Sensor VISIFERM DO accessories Sensor Cap VISICAL calibration tool USB-RS485 Modbus converter With VISIFERM, there is only one consumable. Under normal conditions, even with frequent steam sterilizing, autoclaving, and CIPs, the Sensor Cap has a lifetime of more than one year. Sensor cable VP 8.0 Simplifies air and zero point calibration when using the 4 to 0 ma interface, or when precalibrating the sensor in a laboratory. It also displays overall sensor status, and indicates when a Sensor Cap needs to be replaced soon. VISIFERM-D4 power adapter Connects the VISIFERM DO to a PC with USB port. Power Supply ModBus (RS 485) ModBus RTU Master Device # 01 Device # 0 The PC acts as a Master, using ARC Sensor Configurator freeware or any other Modbus terminal software. ARC Sensor Configurator freeware Device # 3 Various lengths available, see page 37. Connects VISIFERM DO in ECS mode to the cable of classical sterilizable oxygen sensor with four-pole plug (D4, T8) such as HAMILTON s OXYFERM FDA. Includes a wall plug power supply. Why users are excited about VISIFERM DO: Application: S or C effect Maintenance: Sensor Cap is stored in the sensor time and costs Installation: Backwards compatible with classical oxygen sensors, operates with traditional transmitters and SOPs, or - Can be connected directly to a PLC or PCS using a 4 to 0 ma or Modbus RTU interface Name VISIFERM DO 10 VISIFERM DO 160 VISIFERM D5 VISIFERM DO 35 VISIFERM DO 45 0X: 01: Mode 4-0mA 0: Mode ECS VISICAL calibration tool USB-RS485 Modbus converter 4-0 ma galvanic isolation amplifier VISIFERM -D4 power adapter VISIFERM replacement sensor cap Connecting cables: Demo cable (1m, open end) Demo cable (1m, BNC plug, e.g. for Applikon) Demo cable (1m, for New Brunswick-Fermenter) Sensor cable VP 8.0, various lengths Order No. 4 450-0X 4 451-0X 4 45-0X 4 453-0X 4 454-0X 4 410 4 411 4 41 4 413 4 47 355 194 38999-767 38999-768 View page 37 35