1 VISIFERM DO Optical Oxygen Sensors with Integrated Transmitter R THE MEASURE OF EXCELLENCE TM
2 VISIFERM DO: intelligent, optical, dissolved-oxyg Optical oxygen measurement with built-in analyzer, in 12 mm format With VISIFERM DO, HAMILTON is the first company to offer a self-contained oxygen measurement in the popular 12 mm format similar to standard process ph electrodes and classical sterilizable oxygen sensors. Combined in the VISIFERM sensor shaft are: high-temperatureresistant optical electronics, microprocessor, 4 to 20 ma analog output, digital RS 485 interface with ModBus protocol, and ECS interface. The Electro-Chemical Sensor (ECS) interface allows VISIFERM DO to be connected to existing classical measurement amplifiers designed for sterilizable oxygen sensors, such as the HAMILTON OXYFERM. Use of the 4 to 20 ma analog output or the digital RS 485 interface (both integrated into the 12 mm shaft) makes an external measurement amplifier unnecessary, allowing measurement signals to be fed directly into a process control system. Clear favorite in comparison HAMILTON has successfully manufactured steam-sterilizable, autoclavable, CIP-compatible sensors for ph, oxidation/ reduction, conductivity, and oxygen measurement for many years. These classical oxygen sensors are based, as is common in the industry, on Clark Cell technology, in which oxygen diffuses through a membrane and is reduced electrochemically on a precious metal. The electrons involved in this process generate a very small current (nanoamperes) which is converted to an oxygen measurement signal by a measurement amplifier. Sensors such as these have served well for decades, but have their limitations. VISIFERM DO optical sensors demonstrate a number of substantial advantages. This is because users of the VISIFERM DO receive more than just a sensor based on a new measurement principle. VISIFERM DO is a symbiosis of sensor and measurement amplifier an intelligent sensor. Application fields VISIFERM DO sensors have been evaluated in a variety of applications: Biotechnology. VISIFERM DO sensors are developed to be steamsterilized and autoclaved without difficulty. CIP cleaning is also tolerated very well. These properties, along with the standard design form of a classical 12 mm sensor with PG 13.5 thread, make VISIFERM DO superior for use in fermenters and similar demanding applications. Waste water treatment. Ground water monitoring. River water monitoring. Breweries. VISIFERM DO is already being used to monitor carbon dioxide recovery, and is finding further application in the wort tank. Installations in the area of beer and beverage bottle filling are still in various test runs. Cooling water cycles, found in power plants and other applications for trace measurements, are also performing reliably and well. Gas monitoring applications depend on the composition of specific samples. All installations are satisfactory. Comparison of optical dissolved oxygen (top) and a classical (bottom) Clark Cell sensor Lightning bright optics While other suppliers of optical oxygen sensors utilize fragile optical fibers, a single light channel, or two different LEDs, HAMILTON prefers a mechanically- and thermally-stable symmetrical design. O 2 O O O 2 O O O O 2 O 2 2 O 2 O 2 2 O 2 O 2 Sensor shaft Two identical light detectors Color filters Blue LED Robust carrier Luminophore FDA silicone Process media with dissolved oxygen O 2 Symmetrical dual channel optics for perfect function and diagnostics VISIFERM DO measurement principles The unique design of the VISIFERM DO enables HAMILTON to monitor the status of the sensor s blue LED using one of the photodiodes. The photodiode with the red filter measures the oxygen-dependent red light generated on the luminophore through luminescence (fluorescence) caused after exitation by the blue light. Electrons are excited to a higher energy level, and return to their original level after emission of red light.
3 en sensor with integrated transmitter functions Absorption of blue light When the luminophore comes into contact with elemental oxygen, the O 2 molecules absorb the energy, resulting in reduced intensity of red light emission. Absorption of blue light Exited state Exited state Emission of light Energy transfer by collision No light emission This difference in intensity is analyzed by the instrument s self-monitoring system to pinpoint photobleaching (bleaching of the luminophore). High precision measuremet of the optical phase shift between the blue and red light pulses provides accurate indication of oxygen concentration. Normally, the luminophore s excited electrons remain in this state for some time. However, in the presence of oxygen they return to their ground state more quickly. Between the pulsed excitation of the luminophore with blue light and the emission of red light, there is an oxygen-dependent time shift which can be measured as an angle of phase. Measurement, calculation, and output of the measured value occur entirely inside the sensor. Notice that VISIFERM DO sensors measure the partial pressure of oxygen (po 2 ) just as classical sensors do. This can be displayed as % air saturation, concentration in mg/l, ppm, or even as ppb. The measurement range is currently limited to 0.05% to 300% air saturation (4 ppb to 25 ppm). For most applications this measurement range is more than adequate. When calibrating the sensor well, the limit is even below 1 ppb. Operational reliability is paramount A comparison with classical measurement technology The most common malfunction of classical Clark Cells is caused by damage to the mechanically sensitive oxygen membrane. If a membrane is seriously damaged, the chances are good that a visual check will catch the problem. However, if a small, unnoticeable defect develops on the membrane, this becomes apparent only when the electrolyte starts to leak, and the sensor stops working. VISIFERM DO does not suffer from this problem, because it has no fragile membrane and no electrolyte; instead, it has a robust, solid Sensor Cap. Cable transmission of very low Clark Cell currents to amplifiers represents a further problem in demanding industrial environments, because of the risk of chaotic or non-reproducible signals caused by dirty or moist contacts from perspiration on fingers. In addition, vibrations and small fluctuations in temperature can alter cable resistance noticeably. Damp cables and especially, damp connections are often the cause of problems in oxygen and other measurements, such as ph. Measurement results of VISIFERM DO can be sent from the sensor as robust 4 to 20 ma analog, or digital signals. Both are far more tolerant of difficult process conditions than the sensitive (na) signals of a classical electrochemical dissolved oxygen sensor. Signal availability A measuring point that delivers no signal can cause great damage. The signal for process control depends on all the components necessary for that signal. For classical oxygen measurement these are: sensor, sensor cable, measurement amplifier, its power source, and the cable from the measurement amplifier to process control. The weakest link contributes the most to Technology that sets new standards Intelligent Sensor VISIFERM DO gives the designation intelligent sensor new significance: Innovative measurement optics, stable to 130 C, with symmetrically-oriented diagnostic and measurement design. Temperature-resistant electronics built into a 12 mm shaft. Replaceable Sensor Cap containing the sensing element. Digital or analog communication by proven VP 8.0 connector head, complete with PG 13.5 process thread connection. Monitoring of all sensor functions, including status diagnosis of the replaceable Sensor Cap, with corresponding signals to the 4 to 20 ma and digital interfaces. A history of self-monitoring is recorded in the sensor. Configurable using the RS 485 interface with notebook, PC or by using the ModBus RTU connection from the process control system, or with HAMILTON VISICAL. system failure. In classical systems this is clearly the membrane-covered sensor first, and the cable to the measurement amplifier second. With VISIFERM DO, critical small currents are dispensed with, and a robust (milliamperes, not nanoamperes) analog or digital signal is supplied to the measurement amplifier in the sensor. Instead of a disturbance-vulnerable membrane, VISIFERM DO has a robust, replaceable Sensor Cap that is both sensitive and highly selective.
4 VISIFERM DO: intelligent, optical, dissolved-oxyg VISIFERM DO all-in-one sensor: function blocks Cap Optics Processor Memory Interfaces Replaceable Robust, sensing Luminophore FDA conform materials only Dual channel Self diagnostics Diagnostics for luminophore Calibration Sensor health Password check Watch dog Calibration data Cap wear CIP & SIP counter Alarm history TAG#, Serial#, Modbus Fieldbus 4-20 ma (Namur) ECS (Clark cell simulation) Power supply Users love the VISIFERM DO: Application: Maintenance: Installation: No fragile membrane solid Sensor Cap, instead Just one single, simple, replaceable spare part the robust Sensor Cap Backwards compatible with classical oxygen sensors, operates with traditional transmitters and SOP s, or... Instantly stable values Low drift, quick response Flow-independent Electrolyte-free, so no leakage No H2S or CO2 effect THE MEASURE OF EXCELLENCE TM Convenient calibration in the laboratory, because calibration data are stored in the sensor Precalibrated, ready-to-use sensors from stock minimize service time and costs Can be connected directly to a PLC or PCS using a 4 to 20 ma or Modbus RTU interface
5 en sensor with integrated transmitter functions Safe trace measurements Trace measurements with classical sensors are not considered particularly accurate or safe, since in the absence of oxygen, no O 2 molecules are reduced, so no electrical current can flow. The same happens when a cable breaks. VISIFERM DO does not suffer from these problems because it is at low oxygen concentrations that the greatest amount of red light is emitted, and the measured phase shift is at its greatest. 80 phase shift 0 0% 300% air saturation Operational reliability and simple maintenance User friendliness is a critical quality in a sensor. Every procedure made redundant signifies an increase in operational reliability. Achieving simple maintenance is of particular value. So when a problem occurs during the night shift, with only limited personnel available to perform maintenance and calibration, VISIFERM DO really helps. All you have to replace is a Sensor Cap, and it is as quick and easy as opening and closing a bottle of soda: the Sensor Cap twists off, and the new one twists on. Job done. You need only perform calibration in air, although ideally, also in nitrogen or carbon dioxide. The sensor can be conveniently calibrated in the laboratory and remains calibrated for the next process run. Three options to connect Fieldbus: VISIFERM DO offers the widely-used Modbus RTU interface, enabling up to 32 sensors or other devices to be wired onto the same bus, in a highly cost-effective installation. The Modbus interface offers users comprehensive information, including input from the sensor s diagnostics and health indicator. Numerous gateways are available to interface Modbus to Foundation Fieldbus, Profibus, and others. Robust 4 to 20 ma current: Connects VISIFERM DO directly to a PLC or PCS, with no transmitter. ECS: The Electro-Chemical Sensor interface connects VISIFERM DO to traditional transmitters/analyzers for electrochemical oxygen sensors. ECS option can be selected using the VisiConfigurator. VISIFERM DO accessories Sensor Cap VISICAL calibration tool USB-RS485 Modbus converter With VISIFERM, there is only one consumable. Under normal conditions, even with frequent steam sterilizing, autoclaving, and CIPs, the Sensor Cap has a lifetime of more than one year. Furthermore, lifetime is seldom dramatically reduced even in enviromental applications, the Sensor Cap lasts for 3 years and longer. Sensor cable VP 8.0 Simplifies air and zero point calibration when using the 4 to 20 ma interface, or when precalibrating the sensor in a laboratory. It also displays overall sensor status, and indicates when a Sensor Cap needs to be replaced soon. VISIFERM-D4 power adapter Connects VISIFERM DO in ECS mode to the cable of classical sterilizable oxygen sensor with four-pole plug (D4, T82) such as HAMILTON s OXYFERM FDA. Includes a wall plug power supply. Connects a PC with a USB port to the world of Modbus. Power Supply ModBus (RS 485) ModBus RTU Master Device # 01 VISIFERM DO Device # 02 VISIFERM DO The PC acts as a Master, using VisiConfigurator freeware or any other Modbus terminal software. VisiConfigurator freeware Device # 32 VISIFERM DO
6 VISIFERM DO: intelligent, optical, dissolved-oxyg oxyge Technical data Optical oxygen sensor with integrated optoelectronics, measuring-devices functionality, and self-diagnosis. Steam-sterilizable, autoclavable, and CIP-resistant (tested with 1.0 M NaOH, 90 C, 60 minutes). Measurement principle: oxygen-dependent change of phase-angle of FDA silicone-protected luminophore. No minimum flow required, because sensor does not consume oxygen. Always immediately ready for measurement. Shaft diameter: 12 mm, PG 13.5 thread. Different lengths of shaft, from 120 mm (see part description: VISIFERM DO 120 where 120 indicates the shaft length). Replaceable Sensor Caps. Various modes of operation, adjustable by means of software. For example: 4 to 20 ma interface. ECS interface. Device address and transmission rate for operation with Modbus RTU fieldbus. Several sensors can be read by the same two RS-485 interface conductors, for a process control system or a personal system. Cross sensitivities and resistances: Not sensitive to: CO, ethylene oxide, and gamma sterilization Not harmed by: ethanol, methanol, H 2 2 Not resistant to: chlorine gas and other organic solvents such as chloroform, toluene, acetone. Specific data Storage temperature: -10 to 50 C. Operational temperature: -10 to 30 C; disconnection of optical oxygen measurement above 80 C as standard (others on request); electrical interfaces and temperature measurement active up to 130 C. Process pressure: -1 to 12 bar (174 psi); pressure impulses up to 80 bar. Range of measurement: 4 ppb, 0.05% to 300% oxygen/air saturation; measurement unit can be configured by software according to: % oxygen/air saturation (% saturation). Volume-% oxygen (Vol-%). mg/l or ppm. µg/l or ppb. Resolution: 0.1 ppb Response time at 25 C, air to nitrogen: t < 30 s. 98% Detection limit: 0.01 Vol-%. Drift: lower than 0.2 Vol-% oxygen per week in air at 30 C and constant conditions. Electrical connection with VP 8.0 socket head: Operating voltage: 7 to 30 VDC, maximum 1000 mw. Continuous power: approximately 0.6 W. Start-up power: maximum 1 W (as of Firmware Modbus_031 ). Freely scalable, 4 to 20 ma current interface (current sink) for a temperature-compensated oxygen-measurement signal. Fed by external 24 VDC supply (for example), allowing a standard 4 to 20 ma current signal to be used for process control or recording. In the sensor, the current flows towards the ground of the operating voltage. ECS interface for the simulation of a classical, electrochemical sensor (cathode, anode, NTC 22 kω temperature sensor) for operation with classical measuring devices. Fieldbus interface: digital, serial, 2-wire, RS-485 interface, with Modbus RTU protocol. Modbus: Modbus RTU; 2-wire RS-485; maximum of 32 addresses. Transmission / baud rate: 4800 to (factory standard: Bd). Wetted parts materials: SS 316L / DIN , EPDM (FDA), silicone (FDA).
7 n en sensor with integrated transmitter functions VISIFERM DO ordering information Order number Description VISIFERM DO VISIFERM DO VISIFERM DO VISIFERM DO VISIFERM DO VISIFERM DO replacement Sensor Cap (spare part) VISICAL calibration tool USB-RS-485 Modbus converter ma galvanic isolating amplifier M VISIFERM -D4 power adapter Demo cable (1m, open end, power pack) Demo cable (1m, for Sartorius fermenter, power pack) Demo cable (1m, e.g. for Applikon fermenter, BNC plug, power pack) Demo cable (1m, for New Brunswick fermenter, power pack) Sensor cable VP 8.0, 1m Sensor cable VP 8.0, 3m Sensor cable VP 8.0, 5m Sensor cable VP 8.0, 10m Sensor cable VP 8.0, 15m Sensor cable VP 8.0, 20m For armatures, ph and conductivity sensors, patented and certified DURACAL ph buffers, and conductivity standards, please check the HAMILTON website, or consult your HAMILTON process sensors distributor.
8 Website: Support: R HAMILTON Bonaduz AG Via Crusch 8 CH-7402 Bonaduz, Switzerland Toll-Free: Telephone: Fax: [email protected] Your HAMILTON representative: HAMILTON Company 4970 Energy Way Reno, Nevada 89520, USA Toll-Free: Telephone: Fax: Quality HAMILTON Products: Laboratory Electrodes DURACAL ph Buffer Process ph Sensors Conductivity Sensors Conductivity Standards Dissolved Oxygen Sensors Armatures MICROLITER Syringes GASTIGHT Syringes Instrument Syringes SoftGrip Pipettes Miniature Valves Laboratory Automation for: Drug Discovery Genomics Proteomics Forensics In Vitro Diagnostics E/691068/01 11/2008
Stainless Steel Dissolved Oxygen Electrodes
Stainless Steel Dissolved Oxygen Electrodes DISSOLVED OXYGEN ELECTRODES The steam sterilizable family of dissolved oxygen electrodes from the phoenix Electrode Company is specifically designed for fermentation
Dissolved Oxygen Sensors
Instruction Sheet PN 51A-HxDO/rev.F June 2008 Models Hx438 and Gx448 Dissolved Oxygen Sensors For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit
ORBISPHERE M1100: CUSTOMER SUCCESS STORY - CARLSBERG
PRACTICE REPORT PROCESS ANALYSIS OXYGEN MEASUREMENT BREWING ORBISPHERE M1100 CUSTOMER SUCCESS STORY - CARLSBERG Authors: Stephen Bell, Global Product Line Manager, HACH LANGE S.A. Frank Dunand. Senior
OXIGENO DISUELTO. Dissolved Oxygen. Install & forget. Sistema autolimpiable. Autoclean system
Sistema autolimpiable Dissolved Oxygen Autoclean system Applications: - water treatment - activated sludge - de-nitrification - fish pond Install & forget For special applications, the D.O monitor can
Chicago Process Solution Summit: Liquid Analysis Made Easy
Chicago Process Solution Summit: Liquid Analysis Made Easy Contents Memosens Design Capabilities Advantages Transmitters CM44X Series CM44XR series Automated Services TopClean TopCal EtherNet/IP Memosens:
LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring
LNG Monitoring Fiber-Optic Leakage Detection System Pipeline leakage detection Regasification and liquefaction monitoring Tank annulus and base slab monitoring Spill containment control Intelligent Solutions
Vibration analysis and monitoring Compact. Powerful. Modern technology.
Vibration analysis and monitoring Compact. Powerful. Modern technology. Maximum performance Vibration measurement with state of the art processor technology Expert Vibro is Delphin Technology's new device
OEM Optical Competences. Solutions for Optical OEM Applications in Liquid Analysis.
OEM Optical Competences Solutions for Optical OEM Applications in Liquid Analysis. Process Analytical Measurement Solutions Endress+Hauser Conducta Inc. offers a wide range of precision in-line measuring
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and Controllers for Gases Reliable and accurate: Thermal Mass Flow Meters and Controllers Reliable technology and industry standard interfaces
Galvanic Parts Per Million Dissolved Oxygen Systems
Galvanic Parts Per Million Dissolved Oxygen Systems Model 900 Portable s Model 9100 Model 9200 Model 9300 The Royce line of PPM level dissolved oxygen (DO) analyzers is the largest, most varied line in
MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter
Thermal Mass meter and Temperature Transmitter Description The MTI10 insertion thermal mass flowmeter and the MTL10 in-line thermal mass flowmeter provide accurate mass flow measurement of clean, dry gases
RI-215A Operator s Manual. Part Number: 71-0045RK Revision 0 Released: 10/3/05
RI-215A Operator s Manual Part Number: 71-0045RK Revision 0 Released: 10/3/05 Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by us to be free from defects in materials and workmanship,
Short Form Catalogue. Alarm Systems. Reliable Supervision and Control
Short Form Catalogue Alarm Systems Reliable Supervision and Control Alarm Monitors and Indicators The SELCO product range includes a number of alarm monitors and indicator panels for use in numerous applications.
Digital Single Axis Controller
Digital Single Axis Controller The concept of intelligent hydraulic drive a vision? DSAC (Digital Single Axis Controller) Do you need hydraulic servo drive for your machine/system? What would it be like
User Guide. Heavy Duty Dissolved Oxygen Meter. Model 407510
User Guide Heavy Duty Dissolved Oxygen Meter Model 407510 Introduction Congratulations on your purchase of Extech's Heavy Duty Dissolved Oxygen / Temperature Meter which simultaneously displays Dissolved
How To Use A Ds340 (Dsp)
Ideal for monitoring dust levels in the exhaust gas of industrial combustion or air filtration processes. Innovative Dynamic Detection Principle (DDP) measurement technique Immune to gradual reductions
JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410
The INTEG is an Ethernet I/O (digital, analog) device that monitors and controls a small set of process signals. functions as both basic I/O for integration with another application or system AND as a
Documentation. M-Bus 130-mbx
Documentation M-Bus 130-mbx Introduction The mx M-Bus module is part of the mx Smart Slot communications family. With the integrated SmartSlot technology, mx systems ag offers automatic consumer data read-out
Automation System TROVIS 6400 TROVIS 6493 Compact Controller
Automation System TROVIS 6400 TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and process plants for general
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110
PolyGard Carbon Monoxide CO Transmitter ADTX3 1110 DESCRIPTION CO transmitter including digital measurement value processing and temperature compensation for the continuous monitoring of the ambient air
EDI Distributor Control Interface Wiring and Setup Instructions
Universal I/O EDI Distributor Control Interface Wiring and Setup Instructions EDI UNIVERSAL I/O INTERFACE MODULE The only interface needed for EDI-V5 controls Network compatible with all older EDI controls
DissolvedOxygenMonitor
Call 800.959.0299 to speak with a sales representative or visit us on the web at www.analyticaltechnology.com DissolvedOxygenMonitor Model Q46D Dissolved Oxygen Monitoring is critical to stable operation
Single-Use Flow-Through Cell ph FTC-SU-HP8
Single-Use Flow-Through Cell ph FTC-SU-HP8 SENSOR PROBES Instruction Manual Single-Use Flow-Through Cell ph FTC-SU-HP8 Specification: ph sensor stick integrated in a single-use flow-through cell Document
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com
DAM Series DAM124 4DIN+8AI+4DO Module Model No.:DAM124 WebSite: www.gsm-m2m.com This handbook has been designed as a guide to the installation and operation of King Pigeon Hi-Tech.Co.,Ltd DAM series. Statements
IntesisBox Modbus Server SAMSUNG Air Conditioners
IntesisBox Modbus Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung NASA compatible Air Conditioning Systems from any Modbus master device TCP or RTU (BMS, PLC, SCADA, HMI,
Flow-Through Cell ph SENSOR PROBES. Instruction Manual
Flow-Through Cell ph SENSOR PROBES Instruction Manual Flow-Through Cell ph Specification: ph sensor integrated in a flow-through cell Document filename: IM_FTC_pH_dv1 All rights reserved. No parts of
LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER
LLB-OCMFM 2000 PORTABLE DOPPLER AREA-VELOCITY FLOWMETER System for flow measurement, data acquisition and transmission for wastewater with long battery life With Long Life Battery Open Channel Flow Meter
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System
RTM X42 Multi-Channel Radio Transmission Tension Monitoring and Control System RTM X42 is an innovative system that utilizes force measuring rollers to capture the tension of individual wires or strands,
OxyGuard. Dissolved Oxygen Probe
OxyGuard Dissolved Oxygen Probe Standard type USER MANUAL D02 Standard Probe manual gb 0903 CONTENTS 1. DESCRIPTION 1.1 The OxyGuard Probe... 1 1.3 Which kind of transmitter can be used with the OxyGuard
TP32MTT.03 TP32MTT.03.1. [ GB ] Probes for soil thermal profile measurement
TP32MTT.03 [ GB ] Probes for soil thermal profile measurement [ GB ] [ GB ] Description Temperature measurement at 7 levels (TP32MTT.03) or 6 levels () In accordance with the requirements of the World
ngenieros Ingenieros Asociados De Control S.L.
ngenieros sociados de ontrol 1 Company founded in 1985 to serve commercial and technical assistance in the fields of instrumentation, control and installation for all types of industries. We offer top
WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK
WEA-Base User manual for load cell transmitters 1 Contents 1. Technical data... 3 2. Assembly... 4 2.1 Power supply... 4 2.2 Load cells... 4 2.3 RS-485... 4 2.4 Relays... 5 2.5 Digital input... 5 2.6 Analogue
Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry
Optical or Acoustic Process measurement of liquids Turbidity Colour Oil in Water Water in Oil Oil on Water Process UV- Photometry Models UVS-1, MoniSpec-UV & MoniSpec-UVd Model UVS-1 general information
Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION
Modular, Customizable Wire Replacement 128 / 256 Bit AES Encryption Software Selectable RF Transmit Power Software Selectable Over-the-air Data Rate Modbus ASCII /RTU Compatible Wide Operating Temperature
G8 GALILEO. Innovation with Integrity. High-End Melt-extraction Analyzer. Inert Gas Method
G8 GALILEO High-End Melt-extraction Analyzer Innovation with Integrity Inert Gas Method Determination of O, N and H The market demands Metals, minerals, and inorganic compound markets demand high-quality
Perimeter Security System
TM Perimeter Security System The Next Generation Perimeter Security System ICRONET combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience. It is a sophisticated
INTREPID Perimeter Intrusion Detection System
TM INTREPID Perimeter Intrusion Detection System Next Generation Perimeter Protection icropoint Cable combines patented Southwest Microwave technology with microprocessor power and laptop computer convenience.
Regards from the Team at Rheology Solutions.
Rheology Solutions is the sole Australian distributor of this product range and we welcome the opportunity of discussing your application requirements. We hope the information you are seeking is contained
WIRELESS INSTRUMENTATION TECHNOLOGY
BS&B WIRELESS, L.L.C. BS&B WIRELESS, L.L.C. WIRELESS INSTRUMENTATION TECHNOLOGY Printed February 2004 BS&B WIRELESS, L.L.C. 7422-B East 46th Place, Tulsa, OK74145 Phone: 918-622-5950 Fax: 918-665-3904
Resolution selectable from 0.01 and 0.001 ph. Range -2.000 16.000 ph. Accuracy ± 0.002 ph
ph EC DO ph Resolution selectable from 0.01 and 0.001 ph Range -2.000 16.000 ph Accuracy ± 0.002 ph Data logging Manual log on demand manual log on stability Interval logging Temperature readout ( C or
Trace Dissolved Oxygen Sensor
Instruction Sheet PN 51A-499ATRDO/rev.G September 2010 Model 499A TrDO Trace Dissolved Oxygen Sensor For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. CAUTION
Intelligent Mould Flow Monitoring
Intelligent Mould Flow Monitoring The Mouldflo Flow Monitoring System 1 2 The Mouldflo Flow Monitoring System Mouldflo Flow Monitoring System For the first time Mouldflo offers Injection Moulders an affordable
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification
P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification 1.0 This specification details the attributes and operating characteristics of the MSA Ultima X Series sensors/transmitters.
DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors
DrägerSensor EC Electrochemical Sensors Sensor for Fixed Gas Detectors Faster response higher accuracy greater stability longer life. Dräger electrochemical sensors offer all these benefits. The robust
API Marine. BMS Presentation. Ballast Measurement Systems
API Marine BMS Presentation Ballast Measurement Systems BMS4 Typical Configuration BMS4 Typical Configuration BMS4 Extended Configuration BMS4 System (24 tanks) Air regulator Terminal block Drain/Air Filter
S4000TH HART. HART Communication Manual
HART Communication Manual The information and technical data disclosed in this document may be used and disseminated only for the purposes and to the extent specifically authorized in writing by General
Digital inductive conductivity transmitter
Digital inductive conductivity transmitter Optimal solution for conductivity measurements in difficult fluids (polluted, dirty,...) PEEK/PPA version for CIP applications Large range of process connections
COMBIMASS. Technical Data COMBIMASS eco-bio +
COMBIMASS Technical Data THE SYSTEM COMBIMASS The field transmitters of the COMBIMASS eco series are suitable for gas flow measurement and cover a wide range of different applications. The instruments
Thermal Mass Flow Meters and Controllers for Gases
red-y smart series product information Thermal Mass Flow Meters and ontrollers for Gases Reliable and accurate: Thermal Mass Flow Meters and ontrollers Reliable technology and standardized interfaces make
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
Hand-held thermometer Model CTH7000
Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference
LI-7000 CO /H O Analyzer. High Speed, High Precision Differential Analyzer
LI-7000 CO /H O Analyzer 2 2 High Speed, High Precision Differential Analyzer LI-7000 CO 2 /H 2 O Analyzer - Advantages... Page 1 The LI-7000 CO 2 /H 2 O Analyzer The LI-7000 is a high performance, dual
Smart. Scalable. Simple.
Thermo Scientific Wireless Monitoring Solution Smart. Scalable. Simple. providing the protection you need with the simplicity you deserve Thermo Scientific Wireless Monitoring Solution Optimized Sample
Physical Specifications (Custom design available.)
Helmholtz Coils A useful laboratory technique for getting a fairly uniform magnetic field, is to use a pair of circular coils on a common axis with equal currents flowing in the same sense. For a given
SWISS MADE. Series 320 XB MASTER. Analytical. Precision
SWISS MADE MASTER Series Analytical Precision MASTER Series The Precisa 320 high performance series combines precision and quality, and offers the highest metrological performance and advanced integrated
DISSOLVED OXYGEN PROBE
51970-88 DISSOLVED OXYGEN PROBE Introduction This instruction sheet provides information on the Hach Dissolved Oxygen Probe for use with the sension 6 Dissolved Oxygen Meter. The Dissolved Oxygen Probe
Modbus Server SAMSUNG Air Conditioners
IntesisBox Server SAMSUNG Air Conditioners Gateway for monitoring and control of Samsung Air Conditioning Systems from any master device TCP or RTU (BMS, PLC, SCADA, HMI, TouchPanel ) Master TCP Master
Digital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
Series 7500 Torque Sensor
Properties PTO (Power Take-Off) shaft with integrated torque and angle measurement Non-contact measurement system, high robustness Plug & Play solution, no additional electronics required Performance Measurement
Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD
INGOLD Leading Process Analytics Retractable Housings InTrac Retractable Sensor Housings for Harsh Applications Wide Range of Options Intelligent Sensor Locking System Highly Efficient Sensor Cleaning
Option field bus: without bus with profibus DP. Design-Index (Subject to change)
Amplifier / controller cards ED1 Digital amplifier / controller card ED1 for 1 or 2 proportional solenoids 4 analogue inputs, of which 2 for differential inputs 8 digital inputs Card setting via PC, multi-function
The Sievers 900 Series TOC Analyzers
GE Water & Process Technologies Analytical Instruments The Sievers 900 Series TOC Analyzers imagination at work Delivering Next-Generation Ease of Use, Productivity, and Reliability The Sievers* 900 Series
Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8
CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100 Mbps LEDs for display of supply voltage, group and bus errors as well as status and diagnostics Connection
ABB PSPS Erich Steinmann; Generator control-2013
ABB PSPS Erich Steinmann; Generator control-2013 GENERATOR CONTROL THE MODULAR SOLUTION FOR GENERATORS To make sure that power is efficiently converted into electric energy, it is necessary to supervise
kajaanipolarox Measure and Control Active Bleaching Chemicals kajaani
kajaanipolarox Measure and Control Active Bleaching Chemicals kajaani Measured Chemical Meas.range [g/l] Cl 2 (chlorine) 0...4 (chlorine dioxide) 0...1.5 ClO - 2 (chlorite) 0...1.5 / SO 2 or NaHSO 3 (chlorine
T a b l e o f C o n t e n t s
w w w. g e n t e c h e a l t h c a r e. c o m M E D I C A L M O N I T O R I N G, A L A R M A N D C O N T R O L S Y S T E M S I n t e r n a t i o n a l E d i t i o n Technology for a Better Future Company
s!nus-elektrotechnikai bt. Industrial IT & Automation
USB/PPI+ Optoelectronic isolated USB/PPI adapter Optoelectronic isolated USB/PPI adapter, can replace Siemens 6ES7 901-3DB30-0XA0, the largest communication distance of up to 2 kilometers. Not support
TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM
TAC I/NETTM TM TAC s TM has an extensive range ofpre-engineered VAV control sequences, which combined with a fully integrated actuator and airflow transducer, makes it a low Total Installed Cost solution
Measurement Solutions for Refrigeration Technology.
Measurement Solutions for Refrigeration Technology. Digital manifold, leak detection, vacuum measurement, and lots more. Testo refrigeration technology Digital is better: Refrigeration technology expertise
DUST EMISSION MONITORING SYSTEM
Applications Measurement of dust concentration in dry or moist, steamsaturated and corrosive stack gases Monitoring of municipal and hazardous waste and sewage sludge incinerators Monitoring of power plants
Triple Waveband Infra-Red Flame Detection
Minerva S200PLUS Ex ia Intrinsically Safe & Ex d Flameproof Solar Blind Flame Detectors Triple Waveband Infra-Red Flame Detection Key Features Unrivalled black body rejection over a wide range of source
Digital Controllers ACTUATOR COMPATABILITY
Product Specification 36502B DESCRIPTION APECS DPG-21XX-00X Digital Controllers The DPG-21XX-00X digital controller is used primarily to govern diesel or gas fueled engines of generator sets. This microprocessor-based,
The photoionization detector (PID) utilizes ultraviolet
Chapter 6 Photoionization Detectors The photoionization detector (PID) utilizes ultraviolet light to ionize gas molecules, and is commonly employed in the detection of volatile organic compounds (VOCs).
Series 6000 Torque measured metal bellow coupling
Properties Free of float metal bellow coupling with integrated torque measurement Non-contact measurement system, high robustness High torsional stiffness Limited torque of inertia Performance Measurement
Gas sensors for greenhouse measurements
HTG 2020 Fresh Valley Installation Dr. Martin Paplewski Gas sensors for greenhouse measurements Agenda 1. Applications for Gas sensors Which gases should be measured? Which sensor technology should be
Process Alarm Solutions
Process Alarm Solutions Reliable Supervision and Control www.selco.com SELCO flexible alarm panels for supervision and control SELCO provides efficient and reliable solutions for alarm monitoring of electrical
Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:
GE Measurement & Control Ventostat Wall Mount Telaire Wall Mount, Humidity and Temperature Transmitters Features: Patented, Absorption Infrared Gas sensing engine provides high accuracy in a compact low
Global Water Instrumentation, Inc.
Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 Temperature Sensor: WQ101 ph Sensor: WQ201 Conductivity Sensor: WQ301
L-LAS-TB-CL serie. laser light curtains for inline measuring tasks
L-LAS-TB-CL serie laser light curtains for inline measuring tasks Maximum distance 2.000 mm Measurement range 6 up to 98 mm Resolution up to 4 µm up to 1,5 khz scan rate 0-10 V or 4-20 ma analogue output
How To Use Safety System Software (S3)
SPECIFICATION DATA Safety System Software (S3) APPLICATION Safety System Software (S 3 ) is a robust, full featured configuration, diagnostic, programming and real-time monitoring package for integrators
NEW. EVEN MORE data acquisition and test stand automation
NEW EVEN MORE data acquisition and test stand automation the new class of data The plug&play complete package User benefits Expert Series is the latest generation of data acquisition Complete hardware
Set for PROFINET IO in IP20 TI-BL20-EN-PN-4
Cable max. 50 m between interface and read/write head Connection of up to 4 read/write heads via BL ident extension cables Mixed operation of HF and UHF read/ write heads Connectors /S2500 Type code Ident
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series
Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series Special features long life 100 x 10 6 movements outstanding linearity up to ±0.075% choice of plug or cable connection DIN
Operation & Maintenance Manual. Electrochemical (EC) Gas Sensor Family
Operation & Maintenance Manual Electrochemical (EC) Gas Sensor Family For Detection of Oxygen and Toxic Gases Important: Read and understand contents prior to first use. Improper use or operation could
IntesisBox Modbus Server Fidelio IP
IntesisBox Server Fidelio IP Gateway for integration of Micros Fidelio Ho management system into (RTU and TCP) enabled control systems. Integrate your Micros Fidelio Ho management system into your master
German engineering under high pressure
German engineering under high pressure Over 25 years of experience as a manufacturer of sterilizers, autoclaves and lyophilization systems for laboratories, production and research Production-scale autoclaves
psens Pressure Measurement
Mobile Machine Control Solutions psens Pressure Measurement Reliable Compact Versatile Unique Measurement Accuracy psens. Pressure Sensors from Hirschmann MCS Hirschmann pressure transducers are an ideal
PortaSens ll G AS DETECTOR
PortaSens ll G AS DETECTOR ONE DETECTOR... FOR MANY GASES! Sensors can be exchanged quickly and easily without the need for calibration. Sensors are maintained in ready condition in the optional sensor
User Guide. 9708 Dissolved Oxygen Probes
User Guide 9708 Dissolved Oxygen Probes Introduction The Thermo Scientific Orion 9708 dissolved oxygen probe simplifies measurements of dissolved oxygen, particularly Biochemical Oxygen Demand (BOD).
Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care
Sensors / Modules / Monitors Breath Gas Sensing and Monitoring For life supporting systems in intensive, emergency and ambulant care Your competent partner for breath gas sensing and monitoring EnviteC
4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type code. TBPN-L1-FDIO1-2IOL Ident no. 6814053.
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass-fiber reinforced housing Shock and vibration tested Potted module electronics Protection
Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/219
Siemens AG 2010 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters
FMA 3100/3100ST/3300/3300ST Series Thermal Mass Flow Sensors and Meters M-4270/0707, pg. 2 of 29 READ THIS MANUAL COMPLETELY BEFORE ATTEMPTING TO CONNECT OR OPERATE YOUR FLOW SENSOR. FAILURE TO DO SO MAY
DDX 7000 & 8003. Digital Partial Discharge Detectors FEATURES APPLICATIONS
DDX 7000 & 8003 Digital Partial Discharge Detectors The HAEFELY HIPOTRONICS DDX Digital Partial Discharge Detector offers the high accuracy and flexibility of digital technology, plus the real-time display
OT 40L / 90L. Laboratory Steam Sterilizers
OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture
SITRANS F flowmeters SITRANS F M
Overview Integration The complete flowmeter consists of a flow sensor and an associated transmitter MAG 5000, 6000 or 6000 I. The flexible communication concept USM II simplifies integration and update
Common Problems with Online Water Quality Analyzers. Greg Macy Director AquatiPro LLC
Common Problems with Online Water Quality Analyzers Greg Macy Director AquatiPro LLC Objectives Diagnosing Colorimetric Analyzers Identifying Common Problems with Sodium Analyzers Troubleshooting ph Analyzers
Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm
Electronic pressure measurement Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm WIKA data sheet PE 81.67 Applications Machine tools Hydraulics
Fiessler Programmable Safety Center. Flexible Hard- and Software concept. Available with a safe bus system or/and two counter inputs
E L E K T R O N I K Appliance Description Programmable safety center FPSC Fiessler Programmable Safety Center Flexible Hard- and Software concept Available with a safe bus system or/and two counter inputs
Certificate: 0000038506 / 20 August 2013
Test report: 936/21219899/B of 28 March 2013 Initial certification: 23 July 2013 Expiry date: 22 July 2018 Publication: BAnz AT 23 July 2013 B4, chapter II, No. 1.1 Approved application The tested AMS