PET/CT QC/QA. Learning Objectives. Outline

Similar documents
PET/CT QC/QA. Quality Control in PET. Magnus Dahlbom, Ph.D. Verify the operational integrity of the system. PET Detectors

QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET

Rb 82 Cardiac PET Scanning Protocols and Dosimetry. Deborah Tout Nuclear Medicine Department Central Manchester University Hospitals

INTRODUCTION. A. Purpose

Performance Comparison of Four Commercial GE Discovery PET/CT Scanners: A Monte Carlo Study Using GATE

Improvements in quality and quantification of 3D PET images

Quantitative Imaging In Clinical Trials Using PET/CT: Update

Prepublication Requirements

Physics testing of image detectors

Performance testing for Precision 500D Classical R/F System

Quality Control and Maintenance Programs

Truly digital PET imaging

Truly digital PET imaging

CT scanning. By Mikael Jensen & Jens E. Wilhjelm Risø National laboratory Ørsted DTU. (Ver /9/07) by M. Jensen and J. E.

SUBCHAPTER 22 QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS

X- and Gamma Ray Imaging Systems based on CdTe-CMOS Detector Technology

Performance Characteristics of PET Scanners

How To Improve Your Ct Image Quality

CT RADIATION DOSE REPORT FROM DICOM. Frank Dong, PhD, DABR Diagnostic Physicist Imaging Institute Cleveland Clinic Foundation Cleveland, OH

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Spiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

kv-& MV-CBCT Imaging for Daily Localization: Commissioning, QA, Clinical Use, & Limitations

REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22

AN INVESTIGATION INTO THE USEFULNESS OF THE ISOCS MATHEMATICAL EFFICIENCY CALIBRATION FOR LARGE RECTANGULAR 3 x5 x16 NAI DETECTORS

WHERE IN THE WORLD JILL LIPOTI?

Amptek Application Note XRF-1: XRF Spectra and Spectra Analysis Software By R.Redus, Chief Scientist, Amptek Inc, 2008.

Laue lens for Nuclear Medicine

Purchasing a cardiac CT scanner: What the radiologist needs to know

Quality Control of Full Field Digital Mammography Units

Cone Beam Reconstruction Jiang Hsieh, Ph.D.

Fundamentals of Cone-Beam CT Imaging

Breast MRI Quality Control

CT Protocol Optimization over the Range of CT Scanner Types: Recommendations & Misconceptions

CT: Size Specific Dose Estimate (SSDE): Why We Need Another CT Dose Index. Acknowledgements

RapidArc QA Program in Prince of Wales Hospital. Michael L. M. Cheung, Physicist Prince of Wales Hospital Hong Kong

PET and PET/CT in Clinical Trials

Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission

Next Generation Small Animal PET Technology

Personal Identity Verification (PIV) IMAGE QUALITY SPECIFICATIONS FOR SINGLE FINGER CAPTURE DEVICES

Turnkey Solutions for Radiation Protection in PET Laboratories R A D I A T I O N P R O T E C T I O N

Ultrasound Phantoms: B-Mode, Doppler and Others. Heather M. Pierce, B.S. Norfolk, VA

American College of Radiology CT Accreditation Program. Testing Instructions

State-of-the-Art Technology in Cardiac CT

R/F. Efforts to Reduce Exposure Dose in Chest Tomosynthesis Targeting Lung Cancer Screening. 3. Utility of Chest Tomosynthesis. 1.

Contents. X-ray and Computed Tomography. Characterization of X-rays. Production of X-rays

An Overview of Digital Imaging Systems for Radiography and Fluoroscopy

Surveying and QC of Stereotactic Breast Biopsy Units for ACR Accreditation

Evaluation Tools for the Performance of a NESTOR Test Detector

TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-

Q.A. Collectible. Sponsored by CRCPD s Committee on Quality Assurance in Diagnostic X-Ray (H-7)

Proton tracking for medical imaging and dosimetry

Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis

Experimental study of beam hardening artefacts in photon counting breast computed tomography

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

Recognition. Radiation Survey Objectives. Objectives. Part 1 Documentation Radiation Source Survey Objectives Radiation Detectors Techniques

TOF-PET DETECTOR CONCEPT BASED ON ORGANIC SCINTILLATORS

Optimization of image quality through online motion correction

Routine Ultrasound Equipment Tests for Quality Assurance. Contents

Cynthia H. McCollough b) and Michael R. Bruesewitz Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota 55905

CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems

Overview. Creation of 3D printed phantoms for clinical radiation therapy 7/7/2015. Eric Ehler, PhD Assistant Professor University of Minnesota

A software tool for Quality Assurance of Computed / Digital Radiography (CR/DR) systems

M D Anderson Cancer Center Orlando TomoTherapy s Implementation of Image-guided Adaptive Radiation Therapy

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

The accurate calibration of all detectors is crucial for the subsequent data

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

CMS Tracking Performance Results from early LHC Running

Digital Breast Tomosynthesis QC Requirements

Atomic and Nuclear Physics Laboratory (Physics 4780)

2/28/2011. MIPPA overview and CMS requirements. CT accreditation. Today s agenda. About MIPPA. Computed Tomography

Data. microcat +SPECT

How To Use An Ionsonic Microscope

Protocol Management and Review Strategies The MD Anderson Experience

The Importance of Following the PROTOCOL in Clinical Trials

(Amplifying) Photo Detectors: Avalanche Photodiodes Silicon Photomultiplier

Moving Forward What does this mean for the Medical Physicist and the Imaging Community?

Positron Emission Tomography: Principles, Technology, and Recent Developments

Computed Tomography Resolution Enhancement by Integrating High-Resolution 2D X-Ray Images into the CT reconstruction

Radiation Monitoring System DLMon

Avizo Inspect New software for industrial inspection and materials R&D

Power Amplifier Gain Compression Measurements

Clinic. ED Trauma Trauma Stroke. OR Neuro/Spine. Critical Care. Neuro ENT. Diagnostic. Pediatric. Radiology. Plastics Thoracic. Neuro.

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

Tumor. An Brief Introduction to 4D CT Scanning. Outline. Three Types of Motion Artifacts. CT Artifacts in Free Breathing 3D Scan

MEDICAL IMAGING 2nd Part Computed Tomography

Laboratory Technologies, Inc. Multi-Wiper. Time Saving Multiple Detector Wipe Counter

Ultrasonic Load Monitoring

Robot Perception Continued

Description: Multiparameter System (4 or 8 channels)

IAC Ch 41, p.1. Procedure means a stereotactically guided breast biopsy performed on a patient for diagnostic purposes.

Introduction to Geiger Counters

Performance of the Vidar Red LED Dosimetry Pro Advantage : A scanner optimized for use with GAFCHROMIC EBT Dosimetry Film.

DICOM Correction Item

Transcription:

PET/CT QC/QA Magnus Dahlbom, Ph.D. Division of Nuclear Medicine Ahmanson Biological Imaging Center& Ahmanson Translational Imaging Division David Geffen School of Medicine at UCLA Los Angeles 1 Learning Objectives Summarize the signal processing steps for coincidence detection Understand the components of a daily QA procedure Identify and trouble shoot possible sources of failure in daily QA List the recommended frequency of QA/QC tests Describe the process of scanner calibration Name the different components of the NEMA test used for PET acceptance testing Understand the meaning of the results of the NEMA tests. 2 Outline PET Basics PET Detectors and data flow Daily QC Procedures QC Evaluation Techniques Examples of Common Problems Quarterly and Annual QC Procedures 3 1

Quality Control in PET Verify the operational integrity of the system Ensure Stability of the Detectors Ensure Stability of the Acquisition Electronics Maintain consistent and high image quality Minimize chances for image artifacts Catch potential problems early Maintain quantitative accuracy Eliminate unnecessary repeat scans 4 Coincidence Detection Coincidence Detection Amp. Amp. PHA 511 kev? 511 kev? PHA Coinc. Counter Time Resolution: 2-3 ns 2

Coincidence Detection Data Flow in a PET System 8 Time-of-flight PET R R Det 2 Det 1 x R - x R + x s = v t R + x = vt 1 R x = vt 2 2 x = v( t2 t1) x = c t Time Resolution: ~300 ps 2 3

PET Detectors PMT B D << : < ~100% PMT B PMT D : ~0% PET Detectors To identify the detector elements, X- and Y- positions are calculated for each event: Element (4,4) Element (5,3) Pixelated Detector System Continuous-pixelated detector 4

PET Detector Calibration Balancing of PMTs Identification of Peaks/Detectors in Flood Histogram Acquire Energy Spectra / Set Energy Thresholds Time Alignment Challenge: Large number of detector blocks (~200) Large number of detector elements (>30,000) 13 Daily QC Detect small drifts in the system Detector Gain Drifts (Efficiency, Scatter Fraction, Randoms) Timing Quantification Challenges: Large number of detector blocks (~200) Large number of detector elements (>30,000) Time constraint (< 1 hr) 15 5

Daily QC Scan Transmission/Rotating Rod Sources Uniform cylinder phantom (20 cm Ø) Also used for calibration (Counts Bq/ml) Water Phantom Calibrated w. Dose Calibrator Solid 68 Ge Phantom Pre-calibrated 16 Sinogram θ All coincidence lines that are parallel at a given angle form a projection in the sinogram. ρ Sinogram θ All coincidence lines (or lines of response) for a given detector form a diagonal trace in the sinogram. ρ 6

Daily QC / Blank Scan Visually Inspect the sinograms for: Apparent streaks (hot or cold) Consistency Comparison to a reference scan PET Daily QA Scan O. Mawlawi MDACC 7

Normalization θ = z ρ Normalization After Detector Tuning Before PM Normalization After Detector Tuning w. norm Before PM w. norm 8

When things go wrong Normal Detector Failure Detector Controller Failure Sorting Memory Failure Detector Block Failure Detector Block Failure 9

Buchert et. al. JNM 40, 1999 PET Daily QA Scan O. Mawlawi MDACC 30 10

31 System Calibration Calculates Conversion Factor : Image A.U. Bq/ml Scan uniform 20 cm Ø 68 Ge or 18 F Cylinder Calibrated Activity, Time & Volume Emission & Transmission / CT Reconstruct: All corrections applied Standard reconstruction parameters Calibration Factor : Calibrated Act. Conc. / ROI of Image (A.U.) 32 Daily QC Scan / Siemens mct Acquire 68 Ge Cylinder Scan (100-200Mcts) Generation of Normalization Factors Evaluation of Daily QC Components Centered! Block Noise Block Efficiency Measured Randoms Scanner Efficiency Scatter Ratio Calibration Factor) & Image Plane Efficiency Timing Offset, Width and Time Alignment Fit 33 11

Daily QC Scan / Siemens mct 34 Scatter Fraction / Energy Threshold 35 36 12

CT Daily QA Scan Normal operations include the following 3 tasks (in order): Tube Warmup- A built-in prep scan that gradually increases heat loading in the X-ray tube in order to prevent thermal cracking and eliminate the potential for an arc to occur. It includes a series of exposures made at incrementing kvp Daily Air Cals- A built-in prep scan that performs a series of exposures at varying techniques in order to normalize the detector response using air as the attenuating media. These scans essentially adjust the detector gains to achieve a uniform response Daily QA Phantom scan - Provides data for 3 areas of concern in daily quality assurance O. Mawlawi MDACC Quality Control CT daily regimen Scan water layer Measure water HU CTAC Check for artifacts Ring artifacts Redo conditioning Redo Air Cal Austin Health Courtesy: Stefan Eberl, RPA Quarterly QC Procedures Quantification Check Gantry alignment (for PET/CT) Other cross calibrations (well counter, etc) 39 13

Quantification Scan Scan uniform 20 cm Ø 68 Ge or 18 F Cylinder Emission & Transmission / CT Reconstruct: All corrections applied Standard reconstruction parameters Visual inspection Compare image ROI activity to calibrated activity Always perform after any service or detector adjustments 40 Quantification Scan 18 F Cylinder 0.0299 µci/ml FBP OSEM Calculated Atten. Corr. 0.0296-1.1% 0.0295-1.5% Meas. Atten. Corr. CT 0.0285-4.7% 0.0284-4.0% Meas. Atten. Corr. Rods 0.0242-19.2% 0.0239-20.2% 14

PET/CT Gantry Alignment CT PET 15