CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems
|
|
- Tyler Banks
- 8 years ago
- Views:
Transcription
1 CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems GE s Industrial X-ray and CT Forum, Cologne July 7 th 2015 Oliver Brunke GE Sensing & Inspection Technologies GmbH, Wunstorf, Germany Oliver.Brunke@ge.com Imagination at work Copyright 2014 General Electric Company Inspection Technologies 1
2 After more than one decade of CT application in Labs, industrial CT is now moving to drive productivity directly on the factory floor 1. The solution has to cover failure analysis/ndt & Metrology applications 2. Target applications: Cylinder heads & crank cases & turbine blades & fan blades & The system should be capable of fast, automated and reliable pass/fail decisions 4. The inspection solution should drive productivity, cost and reduce Cost of Quality x 2
3 Overview 1. v tome x c: The 450kV CT solution for production applications now with scatter correct for groundbreaking 3D CT data quality 2. 3D Metrology with CT: applications and challenges 3. speed scan CT: ultrafast helix Computed Tomography for casting process productivity and quality improvements Copyright 2014 General Electric Company 3 Inspection Technologies 3
4 GE s phoenix v tome x c: The 450kV CT solution for production applications scatter correct for groundbreaking 3D CT data quality Imagination at work. Inspection Technologies 4
5 scatter correct: fundamentals Cone beam CT (3D) is fast but scattered radiation can affect the image quality Fan beam CT is not affected by scattered radiation but is slow GE s scatter correct utilizes the advantages of both methods
6 scatter correct: the result 1. 9 min 3D-Cone beam CT with imaging artefacts caused by scatter min 2D-Fan beam CT without imaging artfacts 3. scatter correct: speed of 3D-CT with combined with quality of 2D-CT
7 scatter correct process flow First CT scan All further scans of the same sample type Step 1 Acquire projection data Step 1 Acquire projection data Step 2a Acquire correction data (only once per part type) Step 2 Reconstruction of corrected dataset Step 2b Apply correction Step 3 Reconstruction of corrected dataset
8 scatter correct application examples, Turbine blade CT slice without scatter correct CT slice with scatter correct 8 GE Title or job number 7/8/2015
9 scatter correct application examples, Al die casting uncorrected CT scan scatter correct 9 GE Title or job number 7/8/2015
10 scatter correct application examples: Al die casting CT histogram without scatter correct CT histogram with scatter correct 10 GE Title or job number 7/8/2015
11 Das Bild kann zurzeit nicht angezeigt werden. Das Bild kann zurzeit nicht angezeigt werden. scatter correct application examples: phone from 1962 uncorrected CT scan scatter correct 11 GE Title or job number 7/8/2015
12 scatter correct: Performance and productivity improvements CT Quality scatter correct 3D CT Fan beam 2D CT conventional 3D CT Acquisition speed 2D fan beam CT data quality is superior regarding scattering artifacts 3D cone beam CT is 100 x faster than 2D fan beam CT scatter correct combines the productivity of 3D CT with the data quality of 2D CT
13 phoenix v tome x c 450 HS Das Bild kann zurzeit nicht angezeigt werden.
14 Das Bild kann zurzeit nicht angezeigt werden. Das Bild kann zurzeit nicht angezeigt werden. Das Bild kann zurzeit nicht angezeigt werden. v tome x c 450 HS: scatter correct & quick pick 450 kv minifocus X-ray source scatter correct for DXR 16 flat panel detector 4 axis granite based manipulator (X b,y s,z s,r s ) quick pick part exchange system (optional) for automated processing of up to 25 parts Gripper & box design can be adopted to customer parts
15 Overview 1. v tome x c: The 450kV CT solution for production applications now with scatter correct for groundbreaking 3D CT data quality 2. 3D Metrology with CT: applications and challenges 3. speed scan CT: ultrafast helix Computed Tomography for casting process productivity and quality improvements Copyright 2014 General Electric Company 15 Inspection Technologies 15
16 Das Bild kann zurzeit nicht angezeigt werden. GE s v tome x m metrology edition: Precise 3D measurements referring to VDI 2630 guideline Imagination at work. Copyright 2014 General Electric Company Inspection Technologies 16
17 Das Bild kann zurzeit nicht angezeigt werden. phoenix v tome x m 3D metrology Industrial CT process control with extremely high accuracy and reproducibility for Dimensional measurements / wall thickness analyses Nominal-actual CAD comparison Reverse engineering / tool compensation
18 Das Bild kann zurzeit nicht angezeigt werden. phoenix v tome x m metrology edition: System features to ensure measurement precision Designed to ensure long term stability Granite based precision manipulator Temperature stabilized tube and detector Direct measuring system Automatic voxel calibration tool Test phantoms and automatic procedures to determine the specific system values
19 Das Bild kann zurzeit nicht angezeigt werden. Influence of CT system components on measurement accuracy X-Ray tube: Focal spot position: - Focal-object and - Focal-detector-Distance Manipulator: Linearity of magnification axis Detector: Is the detector ideal regarding its geometry? May 12 th 3:30 pm: System requirements for Metrology CT
20 Das Bild kann zurzeit nicht angezeigt werden. Das Bild kann zurzeit nicht angezeigt werden. Das Bild kann zurzeit nicht angezeigt werden. Das Bild kann zurzeit nicht angezeigt werden. Compensation of residual errors to reach < 4 µm accuracy 1. Optimize global geometry: Focal- Object- and Focal-Detector- Distance 2. Adjust remaining non - linearity of manipulator 3. Identify and compensate local geometry: measurement of detector (non) - flatness
21 Compensated Measurement Results Distance error of sphere centers, SD [mm] Non compensated Incl. compensation 0,004 0,004 0,002 0,002 Distance error SD, mm 0,000-0,002-0,004-0,006-0,008-0,010-0, ,000-0,002-0,004-0,006-0,008-0,010-0, ,014-0,014-0,016 Calibrated sphere distance, mm -0,016 Calibrated sphere distance, mm Sphere distance error - v tome x m metrology edition : SD MPE = 4µm +L/100
22 Overview 1. v tome x c: The 450kV CT solution for production applications now with scatter correct for groundbreaking 3D CT data quality 2. 3D Metrology with CT: applications and challenges 3. speed scan CT: ultrafast helix Computed Tomography for casting process productivity and quality improvements 22
23 GE s speed scan CT technology: Das Bild kann zurzeit nicht angezeigt werden. Automated high-speed CT for 3D mass production process control Imagination at work. Copyright 2014 General Electric Company Inspection Technologies 23
24 speed scan CT 64 Das Bild kann zurzeit nicht angezeigt werden.
25 Das Bild kann zurzeit nicht angezeigt werden. speed scan CT 64 Several hundred times faster than conventional industrial fan beam CT Down to 1 minute cycle time with highly automated workflow Ideal for casting process optimization based on statistics Reduced reject rates in serial inspection GE speed ADR integrated in VGInline for optimized 3D defects detection Scanning volume up to 500 x 900 mm Robust design for harsh industrial environments July 8 th 12:00: F. Hansen et al.: speed scan at VW foundry 25
26
On an equal level: CT measurements reach the accuracy of conventional tactile metrology
Comparison of CMM with different sensors On an equal level: CT measurements reach the accuracy of conventional tactile metrology 08.07.2015 Dienste industrielle Messtechnik GmbH; Im Klauenfuß 9, 74172
More informationProper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster. Jesse Garant, JG&A Metrology Center
Proper Implementation of Industrial CT Scanning to Reduce Inspection Costs & Get to Production Faster Jesse Garant, JG&A Metrology Center Traditional Metrology and Inspection Tactile Devices (Touch Probe)
More informationMODERN VOXEL BASED DATA AND GEOMETRY ANALYSIS SOFTWARE TOOLS FOR INDUSTRIAL CT
MODERN VOXEL BASED DATA AND GEOMETRY ANALYSIS SOFTWARE TOOLS FOR INDUSTRIAL CT C. Reinhart, C. Poliwoda, T. Guenther, W. Roemer, S. Maass, C. Gosch all Volume Graphics GmbH, Heidelberg, Germany Abstract:
More informationMethods for analysis and visualization of industrial XCT data of fibre reinforced composites
Methods for analysis and visualization of industrial XCT data of fibre reinforced composites Christoph Heinzl Team DI(FH) Michael Reiter Software development, simulation, dimensional measurement Andreas
More informationCT Traceability - Prof. Wim Dewulf, Group T - KU Leuven
CT Traceability - Calibration and Accuracy Prof. Wim Dewulf, Group T - KU Leuven Outline Introduction: terminology and procedures Voxel size calibration Edge offset calibration Conclusions Outline Introduction:
More informationThinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL
Thinking ahead. Focused on life. REALIZED: GROUNDBREAKING RESOLUTION OF 80 µm VOXEL X-ray ZOOM RECONSTRUCTION Flat Panel Detector (FPD) Automatic Positioning Function For ø 40 x H 40 mm, ø 60 x H 60 mm,
More informationIndustrial X-ray for Nondestructive Testing Unrestricted Siemens AG 2014. All rights reserved
Overview of X-ray Technology and Competence offered by Corporate Technology Industrial X-ray for Nondestructive Testing Nondestructive Testing (NDT) with X-rays: Our offer at a glance High-tech X-ray lab
More informationExperimental study of beam hardening artefacts in photon counting breast computed tomography
Experimental study of beam hardening artefacts in photon counting breast computed tomography M.G. Bisogni a, A. Del Guerra a,n. Lanconelli b, A. Lauria c, G. Mettivier c, M.C. Montesi c, D. Panetta a,
More informationSolder joint inspection and analysis
GE Inspection Technologies Solder joint inspection and analysis with GE s phoenix x-ray microfocus and nanofocus X-ray systems FAQs about X-ray source How X-ray inspection small FOD large FOD works object
More informationAutomotive Applications of 3D Laser Scanning Introduction
Automotive Applications of 3D Laser Scanning Kyle Johnston, Ph.D., Metron Systems, Inc. 34935 SE Douglas Street, Suite 110, Snoqualmie, WA 98065 425-396-5577, www.metronsys.com 2002 Metron Systems, Inc
More informationDevelopment of High Speed Oblique X-ray CT System for Printed Circuit Board
計 測 自 動 制 御 学 会 産 業 論 文 集 Vol. 6, No. 9, 72/77 (2007) Development of High Speed Oblique X-ray CT System for Printed Circuit Board Atsushi TERAMOTO*, Takayuki MURAKOSHI*, Masatoshi TSUZAKA**, and Hiroshi
More informationAvizo Inspect New software for industrial inspection and materials R&D
Avizo Inspect New software for industrial inspection and materials R&D Reduce your design cycle, inspection times, and meet higher-level quality standards at a lower cost. Avizo Inspect software streamlines
More informationReach Higher with Inspection Academy GE s Inspection Technologies Global Knowledge Center. www.geinspectionacademy.com
Reach Higher with Inspection Academy GE s Inspection Technologies Global Knowledge Center www.geinspectionacademy.com Sharing knowledge. Shaping technology. At GE, we know the value of investing in your
More informationDENTAL Cone beam 3D X-RAY SYSTEM with
VERSATILE INTUITIVE efficient DENTAL Cone beam 3D X-RAY SYSTEM with dedicated panoramic imaging With thirty years of experience in designing and manufacturing state-of-the-art dental panoramic and tomographic
More informationEASILY AUTOMATE CT INSPECTIONS AND ANALYSES
VG InLine EASILY AUTOMATE CT INSPECTIONS AND ANALYSES SCAN ANALYZE EVALUATE REPEAT... View the status of your jobs at a glance. With VG InLine, Volume Graphics brings non-destructive testing (NDT) with
More informationCone Beam Reconstruction Jiang Hsieh, Ph.D.
Cone Beam Reconstruction Jiang Hsieh, Ph.D. Applied Science Laboratory, GE Healthcare Technologies 1 Image Generation Reconstruction of images from projections. textbook reconstruction advanced acquisition
More informationHögupplöst Röntgen-tomografi för materialforskning, felsökning och metrologi (mätteknik)
GE Measurement & Control Högupplöst Röntgen-tomografi för materialforskning, felsökning och metrologi (mätteknik) William Gren Sales Manager GE Inspection Technologies GE: A company with global reach 2009
More informationWenzel America Ltd. Andy Woodward
Wenzel America Ltd. Andy Woodward The History of Wenzel 3D Metrology Gear Metrology Optical High Speed Scanning Computed Tomography WENZEL Group Precision on Success Largest family enterprise in this branch
More informationPurchasing a cardiac CT scanner: What the radiologist needs to know
Purchasing a cardiac CT scanner: What the radiologist needs to know Maria Lewis ImPACT St George s Hospital, London maria.lewis@stgeorges.nhs.uk CT scanner development Slice wars 1998 Increased z-coverage
More informationGE Sensing & Inspection Technologies
GE Sensing & Inspection Technologies SOLDER JOINT INSPECTION AND ANALYSIS with phoenix x-ray microfocus and nanofocus X-ray systems FAQs about X-ray source small FOD large FOD object FDD detector high
More informationFundamentals of Cone-Beam CT Imaging
Fundamentals of Cone-Beam CT Imaging Marc Kachelrieß German Cancer Research Center (DKFZ) Heidelberg, Germany www.dkfz.de Learning Objectives To understand the principles of volumetric image formation
More informationQUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET
Centers for Quantitative Imaging Excellence (CQIE) LEARNING MODULE QUANTITATIVE IMAGING IN MULTICENTER CLINICAL TRIALS: PET American College of Radiology Clinical Research Center v.1 Centers for Quantitative
More informationAutomation of a CT Acquisition: A System-based User-Support. 1. Introduction. Bärbel KRATZ 1, Frank HEROLD 1, Malte KURFISS 1
11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Automation of a CT Acquisition: A System-based User-Support More Info at Open Access Database
More informationX-Mind. Instinct for perfection
X-Mind Instinct for perfection X-Mind tubes are located at the back of the head which gives the patient better protection because the distance between the focal spot and the skin is 50% greater than in
More informationWho are we. Engineering & Quality. Elements & Moulds. Verification. Approx. 800 employees. Approx.330 employees. Approx. 26 employees.
Who are we Engineering & Quality Elements & Moulds Verification Approx. 800 employees Approx.330 employees Approx. 26 employees Management Zeiss Manual Calibration Specialists 2012 The LEGO Group Page
More informationApplication Example: Reverse Engineering
Application Example: Reverse Engineering Use of optical measuring technology in the ceramics industry Measuring system: ATOS Keywords: Reverse Engineering, Tool and Moldmaking, Quality Assurance, Ceramic
More informationImage Analysis for Volumetric Industrial Inspection and Interaction
Image Analysis for Volumetric Industrial Inspection and Interaction Rasmus Larsen Mads F. Hansen, Hildur Olafsdottir, Thomas H. Mosbech, Lasse F. Laursen DTU Informatics (CT) reconstruction from few projections
More informationPerformance testing for Precision 500D Classical R/F System
Performance testing for Precision 500D Classical R/F System John M. Boudry, Ph.D. Image Quality Systems Engineer GE Healthcare Technologies Outline System background Image Quality Signature Test (IQST)
More informationDigital panoramic X-ray for practical diagnostics
ORTHOPHOS XG 3 instruments treatment centers Imaging systems cad/cam systems ORTHOPHOS XG 3 Digital panoramic X-ray for practical diagnostics System concept Standard panoramic X-ray with proven technology.
More informationApplication Report. Propeller Blade Inspection Station
34935 SE Douglas Street, Suite, Snoqualmie, WA 9874 Ph: 425-396-5577 Fax: 425-396-586 Application Report Propeller Blade Inspection Station Prepared By Kyle Johnston, Ph. D. Metron Systems Inc.5.5 3 2.5
More informationMicro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity
Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Innovation with Integrity Micro-CT 3D Microscopy Using Micro-CT for SEM Micro-CT for SEM
More informationZEISS T-SCAN Automated / COMET Automated 3D Digitizing - Laserscanning / Fringe Projection Automated solutions for efficient 3D data capture
ZEISS T-SCAN Automated / COMET Automated 3D Digitizing - Laserscanning / Fringe Projection Automated solutions for efficient 3D data capture ZEISS 3D Digitizing Automated solutions for efficient 3D data
More informationVGStudio MAX 2.2 THE MARKET S LEADING APPLICATION SOFTWARE FOR ANALYSIS AND VISUALIZATION OF INDUSTRIAL COMPUTER TOMOGRAPHY / VOXEL DATA
VGStudio MAX 2.2 THE MARKET S LEADING APPLICATION SOFTWARE FOR ANALYSIS AND VISUALIZATION OF INDUSTRIAL COMPUTER TOMOGRAPHY / VOXEL DATA INDUSTRIAL CT MANAGEABLE, AFFORDABLE, PRECISE VOLUME GRAPHICS Volume
More informationOptical Digitizing by ATOS for Press Parts and Tools
Optical Digitizing by ATOS for Press Parts and Tools Konstantin Galanulis, Carsten Reich, Jan Thesing, Detlef Winter GOM Gesellschaft für Optische Messtechnik mbh, Mittelweg 7, 38106 Braunschweig, Germany
More information3-D Printing Artificial Reservoir Rocks to Test Their Petrophysical Properties*
3-D Printing Artificial Reservoir Rocks to Test Their Petrophysical Properties* Sergey Ishutov 1 and Franciszek Hasiuk 1 Search and Discovery Article #41427 (2014) Posted August 29, 2014 *Adapted from
More information3D/4D acquisition. 3D acquisition taxonomy 22.10.2014. Computer Vision. Computer Vision. 3D acquisition methods. passive. active.
Das Bild kann zurzeit nicht angezeigt werden. 22.10.2014 3D/4D acquisition 3D acquisition taxonomy 3D acquisition methods passive active uni-directional multi-directional uni-directional multi-directional
More informationVeraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.
Veraview IC5 HD High definition, digital imaging excellence Thinking ahead. Focused on life. Thinking ahead. Focused on life. 2 3 IC5 HD Super High-Speed with High Definition Clarity For dental radiology
More informationMDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington
MDCT Technology Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington ACMP Annual Meeting 2008 - Seattle, WA Educational Objectives Historical
More information4D Scanning. Image Guided Radiation Therapy. Outline. A Simplified View of the RT Process. Outline. Steve B. Jiang, Ph.D.
4D Scanning Steve B. Jiang, Ph.D. Department of Radiation Oncology jiang.steve@mgh.harvard.edu http://gray.mgh.harvard.edu/ Outline Problems with free breathing 3D scanning What is 4D CT? How does it work?
More informationWe bring quality to light. MAS 40 Mini-Array Spectrometer. light measurement
MAS 40 Mini-Array Spectrometer light measurement Features at a glance Cost-effective and robust CCD spectrometer technology Standard USB interface Compatible with all Instrument Systems measuring adapters
More informationHIGH RESOLUTION X-RAY MICRO-CT OF ULTRA-THIN WALL SPACE COMPONENTS
HIGH RESOLUTION X-RAY MICRO-CT OF ULTRA-THIN WALL SPACE COMPONENTS D. J. Roth 1, R. W. Rauser 2, R. R. Bowman, 1 P. J. Bonacuse, 1 R. E. Martin 3, I. E. Locci, 2 and M. Kelley 4 1 NASA Glenn Research Center,
More informationPipeline External Corrosion Analysis Using a 3D Laser Scanner
Pipeline Technology Conference 2013 Pipeline External Corrosion Analysis Using a 3D Laser Scanner Pierre-Hugues ALLARD, Charles MONY Creaform, www.creaform3d.com 5825 rue St-Georges, Lévis (QC), Canada,
More informationI-Max Touch Range. PAN / CEPH / 3D digital panoramic unit. Evolutive 3 in 1 panoramic unit
I-Max Touch Range PAN / CEPH / 3D digital panoramic unit Evolutive 3 in 1 panoramic unit 3D A new dimension for a complete diagnosis I-Max Touch 3D Evolutive, simple, fast The panoramic unit realizes complete
More informationMODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM
MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM João Antônio Palma Setti, j.setti@pucpr.br Pontifícia Universidade Católica do Paraná / Rua Imaculada
More informationRole of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis
Role of the Medical Physicist in Clinical Implementation of Breast Tomosynthesis Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School Digital Breast Tomosynthesis
More informationAPPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS
APPLICATION OF X-RAY COMPUTED TOMOGRAPHY IN SILICON SOLAR CELLS V.A. Popovich 1, W. Verwaal 2, M. Janssen 1, I. J. Bennett 3, I.M.Richardson 1, 1. Delft University of Technology, Department of Materials
More informationInspection of diffusely reflecting surfaces
surfacecontrol Inspection of diffusely reflecting surfaces 2 Surface control with fringe projection 3 Industrial surface inspection Requirements High quality finished surfaces are a challenge for many
More informationX-ray Tomography in Industrial Metrology
verlag moderne industrie X-ray Tomography in Industrial Metrology Precise, Economical and Universal Ralf Christoph and Hans Joachim Neumann This book was produced with technical collaboration of Werth
More informationScan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13
Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis Tushita Patel 4/2/13 Breast Cancer Statistics Second most common cancer after skin cancer Second leading cause of cancer
More informationTumor. An Brief Introduction to 4D CT Scanning. Outline. Three Types of Motion Artifacts. CT Artifacts in Free Breathing 3D Scan
An Brief Introduction to 4D CT Scanning Steve B. Jiang, Ph.D. Dept of Radiation Oncology Univ of California San Diego Outline Problems with free breathing 3D scanning What is 4D CT? How does it work? Acknowledgements
More informationTHE DOSIMETRIC EFFECTS OF
THE DOSIMETRIC EFFECTS OF OPTIMIZATION TECHNIQUES IN IMRT/IGRT PLANNING 1 Multiple PTV Head and Neck Treatment Planning, Contouring, Data, Tips, Optimization Techniques, and algorithms AAMD 2013, San Antonio,
More informationRenishaw 2008. apply innovation TM. Calibrating 5-axis machines to improve part accuracy. 5Align
Calibrating 5-axis machines to improve part accuracy 5Align Productive Process Pyramid TM Understanding and tracking machine behaviour Process verification Thermal compensation In-cycle process control
More information3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage
3D SCANNERTM 3D Scanning Comes Full Circle Relative 3D Dosimetry offering the easiest setup, most objectivity, and best consistency available The 3D SCANNER Advantage Advanced Design Ring and diameter
More informationStudy of porosity measurement using the computer tomograph
Study of porosity measurement using the computer tomograph Tomasz Kowaluk, Adam Woźniak Institute of Metrology and Biomedical Engineering, Warsaw University of Technology Abstract: This paper is concerned
More informationQUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES. (a) Applicability. (b) Definitions
QUALITY ASSURANCE PROGRAMS FOR DIAGNOSTIC RADIOLOGY FACILITIES (a) Applicability Quality assurance programs as described in paragraph (c) of this section are recommended for all diagnostic radiology facilities.
More informationMachine Tool Inspection & Analyzer solutions
Machine Tool Inspection & Analyzer solutions Introduction IBS Precision Engineering machine tool inspection series offers a range of products to provide peace of mind and control to machine operators by
More informationPreciTrack3D GmbH. PRECI 3D TRACK PRECI 3D GUN PRECI 3D SCAN PRECI 3D ROBOGUN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRODUCTS
HIGHLIGHTS 3D Real Time Tracking Quality Control & Inspection Reverse Engineering ID 2D 3D Scanning PRODUCTS PRECI 3D TRACK PRECI 3D SCAN PRECI 3D CONFOCAL PRECI 3D REF Tube Inspection & Measurements PRECI
More informationCalibration of AFM with virtual standards; robust, versatile and accurate. Richard Koops VSL Dutch Metrology Institute Delft
Calibration of AFM with virtual standards; robust, versatile and accurate Richard Koops VSL Dutch Metrology Institute Delft 19-11-2015 VSL Dutch Metrology Institute VSL is the national metrology institute
More informationMelting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION
M A N U A L M E L - T E M P THE LOWEST COST MELTING POINT APPARATUS FOUND ANYWHERE! Low cost unit Temperature range to 500 C Aluminum casting conducts and radiates heat uniformly to capillaries and thermometer.
More informationGOM Optical Measuring Techniques. Deformation Systems and Applications
GOM Optical Measuring Techniques Deformation Systems and Applications ARGUS Forming Analysis ARGUS Deformation analysis in sheet metal and forming industry Forming Characteristics of Sheet Metals Material
More information3/12/2014. Disclosures. Understanding IAC CT Accreditation. Outline. Learning Objectives. Who is the IAC?
Disclosures Understanding IAC CT Accreditation Serve as one of two AAPM representatives to IAC CT Board of Directors, Serve as IAC representative to AAPM for focus group on accreditations Provide 3-hour
More informationOR Technology. Non Destructive Testing (RT) Strong Workmate for
OR Technology Strong Workmate for Non Destructive Testing (RT) Who We Are What We Do OR Technology Digital X-ray and Imaging Solutions producing digital X-ray technology and developing image management
More informationMEASURING MACHINES. Pratt & Whitney METROLOGY LABORATORY. Measurement Systems, Inc.
METROLOGY LABORATORY Pratt & Whitney Measurement s, Inc. METROLOGY LABORATORY The Standard of Accuracy Pratt & Whitney Metrology Laboratory Machines are the standard of accuracy to which all other gages
More informationOPTICAL MEASURING MACHINES
OPTICAL MEASURIN MACHINES SYLVAC SCAN Dedicated to the fast and contactless measuring of cylindrical parts, our new SCAN machines are based on the principle of the scanner. This technique allows to reproduce
More informationProMetal Rapid Manufacturing
ProMetal Rapid Manufacturing Rapid Metal Casting for Defense Applications CTMA 2005 Jeffrey McDaniel ProMetal Rapid Casting Technology Introduction Technology Applications In the News: ProMetal A Division
More informationQuality Control and Maintenance Programs
Quality Control and Maintenance Programs Cari Borrás, D.Sc., FACR, FAAPM Visiting Professor DOIN-DEN / UFPE Recife, Pernambuco, Brazil Co-Chair, IUPESM Health Technology Task Group 1 Medical Imaging Equipment
More informationCS Solutions. Introducing the CS Solutions portfolio for streamlined CAD/CAM restorations
CS Solutions Introducing the CS Solutions portfolio for streamlined CAD/CAM restorations Discover the products that make restorative treatment in one appointment a reality CS 9300 / 9000 3D CS 3500 SCAN
More informationDICOM Correction Item
Correction Number DICOM Correction Item CP-626 Log Summary: Type of Modification Clarification Rationale for Correction Name of Standard PS 3.3 2004 + Sup 83 The description of pixel spacing related attributes
More informationBIG data big problems big opportunities Rudolf Dimper Head of Technical Infrastructure Division ESRF
BIG data big problems big opportunities Rudolf Dimper Head of Technical Infrastructure Division ESRF Slide: 1 ! 6 GeV, 850m circonference Storage Ring! 42 public and CRG beamlines! 6000+ user visits/y!
More informationData. microcat +SPECT
Data microcat +SPECT microcat at a Glance Designed to meet the throughput, resolution and image quality requirements of academic and pharmaceutical research, the Siemens microcat sets the standard for
More informationInternational Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters
www.led-professional.com ISSN 1993-890X Trends & Technologies for Future Lighting Solutions ReviewJan/Feb 2015 Issue LpR 47 International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in
More informationSpiral CT: Single and Multiple Detector Systems. AAPM Refresher Course Nashville, TN July 28,1999
Spiral CT: Single and Multiple Detector Systems AAPM Refresher Course Nashville, TN July 28,1999 Mike McNitt-Gray, PhD, DABR Assistant Professor UCLA Radiological Sciences mmcnittgray@mednet.ucla.edu X-Ray
More informationHow To Program A Laser Cutting Robot
Robotics ABB Robotics Laser Cutting Software High precision laser cutting made easy - Greater manufacturing flexibility at lower capital investment Robotic laser cutting Overview Allows for the increased
More informationChecklist for the Qualification of Digital Detector Array Systems
Paper No. 010-12 Checklist for the Qualification of Digital Detector Array Systems 1 February 2012 This document was created by the Federal Working Group on Industrial Digital Radiography. Reproduction
More information* This work is an official contribution of the National Institute of Standards and Technology and
Variability in the Geometric Accuracy of Additively Manufactured Test Parts A.L. Cooke and J.A. Soons National Institute of Standards and Technology * Gaithersburg, MD, USA Abstract This paper describes
More informationTISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-
QUALITY Tissue Benefits Mimicking of s RMI recognized RMI as the ultrasound standard phantoms for quality are performance the ultrasound labs ofand hospitals, manufacturers. clinics Sophisticated and ultrasound
More informationGated Radiotherapy for Lung Cancer
Gated Radiotherapy for Lung Cancer Steve B. Jiang, Ph.D. Depart Of Radiation Oncology University of California San Diego sbjiang@ucsd.edu radonc.ucsd.edu/research/cart Two Types of Gating Internal gating
More informationAutomatisierte, hochpräzise Optikmontage Lösungen für die Industrie
Automatisierte, hochpräzise Optikmontage Lösungen für die Industrie Alexander Steinecker, CSEM Trends in Micro Nano, HSLU, Horw, 5. Dezember 2013 High power laser sources Motivation Laser manufacturing
More informationRadiation Protection in Radiotherapy
Radiation Protection in Radiotherapy Albert Lisbona Medical Physics Department CLCC Nantes Atlantique 44805 Saint-Herblain France a-lisbona@nantes.fnclcc.fr Radiation therapy The lecture is oriented to
More informationp h a s e d - a r r a y t e c h n o l o g i e s w w w. m 2 m - n d t. c o m M2M today c o n t a c t @ m 2 m - n d t. c o m
M2M today Overview M2M was created in November 2003 after a 3-year R&D program aiming for the development of an innovative ultrasonic phased array device M2M develops, produces and sells Ultrasonic systems
More informationPRODUCT BROCHURE 7.10.7 SF. Shop-Floor Coordinate Measuring Machine
PRODUCT BROCHURE 7.10.7 SF Shop-Floor Coordinate Measuring Machine HEXAGON METROLOGY 7.10.7 SF Quality Insight at the Point of Production The Hexagon Metrology 7.10.7 SF is like a machine tool for quality
More informationCutting Edge Digital Radiography Technology in Daily NDT Use
Cutting Edge Digital Radiography Technology in Daily NDT Use Ron PINCU, Eli DAYAN, Ofra KLEINBERGER Vidisco Ltd. Or-Yehuda, Israel 60375 Tel: +972 (3) 533-3001 Email: ndt@vidisco.com ABSTRACT Digital Radiography
More informationSmart moulds intelligente Formen
1 Positioning Factory Automation Enterprise Layer SOLVE IT! Control Layer I/O-Layer BUS IT! Connectivity Layer CONNECT IT! Sensor Layer SENSE IT! 2 What is an intelligent chocolate mould? Data can be written
More informationTwo years ANR Post Doctorate fellowship Mathematics and Numerics of Dynamic Cone Beam CT and ROI Reconstructions
Two years ANR Post Doctorate fellowship Mathematics and Numerics of Dynamic Cone Beam CT and ROI Reconstructions Laurent Desbat TIMC-IMAG, UMR 5525, Grenoble University, France Laurent.Desbat@imag.fr Rolf
More informationDESIGN & PROJECT MANAGEMENT
AIM recognises that the success of any project depends upon the presence of a robust project management process and structure. In recent years the company has made considerable investment in personnel,
More informationNational Performance Evaluation Facility for LADARs
National Performance Evaluation Facility for LADARs Kamel S. Saidi (presenter) Geraldine S. Cheok William C. Stone The National Institute of Standards and Technology Construction Metrology and Automation
More informationStudy the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter
Study the Quality Assurance of Conventional X-ray Machines Using Non Invasive KV meter T.M.Taha Radiation Protection Department, Nuclear Research Center, Atomic Energy Authority, Cairo.P.O.13759 Egypt.
More informationView of ΣIGMA TM (Ref. 1)
Overview of the FESEM system 1. Electron optical column 2. Specimen chamber 3. EDS detector [Electron Dispersive Spectroscopy] 4. Monitors 5. BSD (Back scatter detector) 6. Personal Computer 7. ON/STANDBY/OFF
More informationCT for non-destructive testing of plastic joints
CT for non-destructive testing of plastic joints B. Baudrit, S. Horlemann, E. Kraus 24. October 2013 German-Austrian-Danish Workshop on Industrial CT Scanning, TUM, Munich List of contents Introduction
More informationRadiation Safety Characteristics of the NOMAD Portable X-ray System
Radiation Safety Characteristics of the NOMAD Portable X-ray System D. Clark Turner 1, Donald K. Kloos 1, Robert Morton 2 1 Aribex, Inc., 754 South 400 East, Orem, UT 84097 USA, www.aribex.com 2 Quality
More informationEasy Quality Control with - PTW Equipment. Code of Practice - Quality control of X-ray equipment in diagnostic radiology
Easy Quality Control with - PTW Equipment Code of Practice - Quality control of X-ray equipment in diagnostic radiology Revised edition October 2010 Code of Practice- Quality control of X-ray equipment
More informationUnmatched Metal Hardness Testing
Unmatched Metal Hardness Testing The Equostat 3 hardness tester can be connected both to the portable Equotip 3 platform and directly to a PC, with graphic user guidance Hardness Measurements made easy
More informationThe Basics of Scanning Electron Microscopy
The Basics of Scanning Electron Microscopy The small scanning electron microscope is easy to use because almost every variable is pre-set: the acceleration voltage is always 15kV, it has only a single
More informationDigital Dental X-ray. Midmark Animal Health Products
Digital Dental X-ray Midmark Animal Health Products Disease you can't see... 60% of periodontal disease lies below the gum line, and many issues aren't detectable via probing or visual inspection.* Don't
More informationCopyright 2003 T. A. Grimm & Associates, Inc. All rights reserved.
Complete report available at www.tagrimm.com To purchase the full Rapid Prototyping Benchmark of 3D Printers, visit www.tagrimm.com/benchmark/. The 55-page benchmark report includes 34 charts, 5 tables
More informationREGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22
REGULATION: QUALITY ASSURANCE PROGRAMS FOR MEDICAL DIAGNOSTIC X-RAY INSTALLATIONS N.J.A.C. 7:28-22 New Jersey Department of Environmental Protection Bureau of Radiological Health PO Box 415 Trenton NJ
More informationChapter 3 SYSTEM SCANNING HARDWARE OVERVIEW
Qiang Lu Chapter 3. System Scanning Hardware Overview 79 Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW Since all the image data need in this research were collected from the highly modified AS&E 101ZZ system,
More informationApplication Example: Rapid Manufacturing. Toolmaking: Milling on digitized data, Casted Blanks
Application Example: Rapid Manufacturing Toolmaking: Milling on digitized data, Casted Blanks Measuring Systems: ATOS Keywords: casted blanks, stamping process, cutter path, toolmaking Big tools or dies
More informationStandard Test Method for Classification of Film Systems for Industrial Radiography 1
Designation: E 1815 96 (Reapproved 2001) Standard Test Method for Classification of Film Systems for Industrial Radiography 1 This standard is issued under the fixed designation E 1815; the number immediately
More information