TABLE OF CONTENT

Similar documents
TABLE OF CONTENT

STREETLIGHT SYSTEM GROUNDING AND BONDING

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Hyperlinks are Inactive

800 Communications Circuits

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

TABLE OF CONTENT

GROWTH MANAGEMENT DEPARTMENT 201 SE 3 rd ST, (Second Floor), Ocala, FL (352) ; FAX: (352)

Grounding & Bonding Why it is done And How to Install Properly

Specifications for Lightning Protection. ASAE Engineering Practice

Electrical Grounding. Appendix C

TABLE OF CONTENT

GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

ELECTRICAL SAFETY Information Bulletin

Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

SECTION 22 LIGHTNING PROTECTION SYSTEM

Grounding of Electrical Systems NEW CODE: Grounding and Bonding

Application Bulletin NEC Reference Guide for SolarBridge-Enabled AC Module Installers

SAES-P January, 2004 Grounding. Electrical Systems Designs & Automation Standards Committee Members

MOBILE HOME SERVICE REQUIREMENTS GAS

Ontario Electrical Safety Code - Info Sheet

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

TABLE OF CONTENT

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Lightning Protection Introduction

RESIDENTIAL ELECTRICAL REQUIREMENTS (REVISED 3/28/2008) PERMIT REQUIREMENTS:

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

1. Division 26 Section "Underground Ducts and Utility Structures" for ground test wells. 2. Division 26 Section Electrical General Requirements.

Chapter 9. Bonding and Grounding

Title: Grounding and Bonding Rev-01

Electrical Code Regulation

GroundRod AC Substation Earthing Tutorial

STORAGE TANK SELECTION AND SIZING (ENGINEERING DESIGN GUIDELINE)

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Requirements for Electrical Installations

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

TABLE OF CONTENT

LEAD FREE FIREX. Interlock Armored Cables TECK90 and MC Industrial Cables. w w w. n e x a n s e n e r g y. c o m

CONFLEX ELECTRIC CABLE

SPECIFICATIONS FOR THE INSTALLATION OF FIRE ALARM SYSTEMS, SPRINKLER SYSTEMS, AND MASTER BOXES IN THE POQUONNOCK BRIDGE FIRE DISTRICT

Substation Grounding Study Specification

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

TC Grounding and Bonding for Telecommunications Systems

GUIDELINES HAS/PDC/DESIGN DIVISION TITLE

TABLE OF CONTENT

1. Franklin Rod Performance 2. LEC/DAS Performance

KNOW YOUR OPTIONS: 230 KV POWER CABLES

AT&T Specifications Trenching Conduit Boxes and M anholes Aerial Entrance Masts Service Cabinets Bonding and Grounding

Homeowner Information Guide Electrical Safety. British Columbia Safety Authority

SYSTEM 1850-SE SERVICE ENTRANCE CABLE SYSTEM

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

Unified requirements for systems with voltages above 1 kv up to 15 kv

Please check with your local inspection authority for any additional requirements before installation.

GENERAL ELECTRICAL REQUIREMENTS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

Section kv Power Cables

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

Utility Marking Trace Wire Guide

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

KNOW YOUR OPTIONS: 69 KV XLPE POWER CABLE

MEDIUM VOLTAGE CE-BF SWITCHBOARDS. UP TO 40.5 kv. CE - BF - C - en - REV

Session 14 Cable Support Systems

Underground Service Requirements and Instructions

GUIDELINES FOR WIRING SINGLE FAMILY DWELLING UNITS

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Errors Related to Cable Resistance Imbalance in Three Wire RTDs

International Electrotechnical Commission Standards

4 Installation Requirements

Lightning Arresters P KVA P KVA. Description & Installation

Customer Substation Manual 08/05/02

FIREFINDER XLS ADDRESSABLE FIRE ALARM SYSTEM SECTION 13851

GAS INSTALLERS MANUAL CINERGY AND SUBSIDIARY COMPANIES CUSTOMER PROCEDURE FOR INSTALLING 3", 4", 6", AND 8" IPS PLASTIC GAS SERVICE PIPING

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

CHAPTER 2 EXAMPLES AND TABLES

Assessment of Soil Resistivity on Grounding of Electrical Systems: A Case Study of North-East Zone, Nigeria

Residential Electrical Inspection. Checklist

Grounding Practice at Data and Communications Centers. David Brender, P.E., CPQ National Program Manager Copper Development Association Inc.

Carlon Expansion Fittings for PVC Rigid Nonmetallic Conduit

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

PLEASE NOTE. For more information concerning the history of these regulations, please see the Table of Regulations.

CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE

TABLE OF CONTENT

How To Get A Power Line Extension

Cable Selection for Medium Voltage Capacitor Banks and Harmonic Filter Banks

DEPARTMENT OF LICENSING AND REGULATORY AFFAIRS DIRECTOR S OFFICE CONSTRUCTION SAFETY STANDARDS

INSPECTION GUDELINES

AC and DC Drive System Installation Information

North Carolina FFA Association Agricultural Mechanics Career Development Event

Tri-Rated Flexible PVC Equipment Wire

Underground Commercial Electric Service

IRRIGATION PUMPING Table of Contents - Section 900

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

Residential Electrical Inspection. Checklist

Transcription:

Page : 1 of 23 Project Engineering Standard www.klmtechgroup.com KLM Technology #03-12 Block Aronia, Jalan Sri Perkasa 2 Taman Tampoi Utama 81200 Johor Bahru Malaysia TABLE OF CONTENT SCOPE 2 REFERENCES 2 DEFINITIONS AND TERMINOLOGY 2 BONDING AND GROUNDING MATERIALS AND METHODS 3 Bonding and Grounding Conductors 3 Bonding and Grounding Connections 4 Grounds 5 Substation and Generating Station Grounds 6 SYSTEM NEUTRAL GROUNDS 6 Ground Resistance 6 Grounding Conductor Size 6 Grounding Conductor Insulation 7 ENCLOSURE GROUNDING 7 Wiring Systems 7 Wiring Systems 8 Equipment 8 Ground Returns 9 Conduit Ground Returns 9 Ground Return Through Flexible Conduit 10 FOR POWER SYSTEMS 11 STRUCTURE LIGHTNING PROTECTION 13 BONDING AT LOADING STATIONS 14

Page 2 of 23 SCOPE This Project Standard and Specification covers requirements governing the grounding, over voltage protection, and lighting protection facilities for electrical power system and equipment, structures and buildings. This Project Standard and Specification does not cover process instrumentation system. REFERENCES Lighting protection for structures without metallic frames or siding shall be in accordance with ANSI Standard C5.1, Lighting Protection Code, or equivalent national standard. DEFINITIONS AND TERMINOLOGY Acceptable and preferred practices - Where this Project Standard and Specification list more than one type of equipment or method as acceptable, the Contractor shall make the selection based on the installed cost. Where one particular type of equipment or method is listed as preferred, it shall be selected, provided it is lower or equivalent in installed cost than other acceptable type or methods. Bonding - Two or more objects are considered to be bonded if connected together through a conducting path. Objects which are not inherently in contact with each other through a conducting path may be bonded by connecting them together with a bonding conductor. Equipment - The term equipment as used in this Project Standard and Specification applies to all electrical distribution, control and utilization components and includes such as transformers, panel boards, lighting fixtures, receptacles, switching devices, and motors. Ground return path - A metallic connection between the metal enclosure of electrical equipment and the system neutral ground of the power supply to the equipment. If the system neutral is grounded through impedance, the ground return path must connect on the ground side of the impedance. Grounding - An object is considered to be grounded when connected by a conducting connection, either inherently or by a grounding conductor, to the earth.

Page 3 of 23 Grounds - Grounding electrodes, buried grounding conductors, or underground metallic water piping. Liquids - Are classified as accumulators if their conductivity is 50 picomhos/meter or less. Distilled petroleum products including petroleum solvents, are generally accumulators. Crude oil, residual fuel oil, asphalt (both penetration or cutback), Bunker C, residual products with Conradson carbon above 1% and water soluble products such as alcohol have high conductivity and are classified as non-accumulators. Switch loading - Loading a high flash cargo into a shipping vessel previously containing a low flash cargo, without cleaning or gas freeing the vessel. The high flash cargo must be treated as low flash during loading in such cases. The zone of lighting protection - The space enclosed by a cone with its apex at the highest point of a properly grounded rod, wire, or metal structure and has a radius at its base of twice the height of the rod. BONDING AND GROUNDING MATERIALS AND METHODS Bonding shall be provided where necessary to insure the electrical continuity of grounding circuits and where necessary to provide a path for the dissipation of static charges. Bonds provided for the dissipation of static charges shall have a resistance of one meg ohm or less. Bonding and Grounding Conductors 1. Bonding, grounding, and buried ground return conductors shall be bare stranded medium-hard-drawn copper. Minimum sizes shall be 2 Awg. (32 mm2, 0.05 in 2 ) for underground conductors and 6 Awg. (13 mm 2, 0.02 in 2 ) for aboveground conductors. 2. Ground return conductors located within cable assemblies may be uninsulated and shall be of the same material and stranding as the cable line conductors. 3. Conductors sizes shall be increased above the minimum sizes if required to: - Insure adequate mechanical strength. - Withstand the thermal stresses of ground fault currents. 4. Grounding conductor burial depths shall be at least 18 inches. Burial depths in switch or transformer yards graded with stone shall be at least 12 inches below the stone.

Page 4 of 23 5. If the wiring method is buried cable, grounding conductors shall be laid in the cable trenches as far as routing permits. 6. If the wiring method is underground conduit, grounding conductors shall be laid along a formed side of the duct banks as far as routing permits. 7. Where grounding cables cross under railroads, main roads, paved roads, or concrete paved areas, they shall be run in rigid metal conduit, pipe sleeves, or duct banks as required for wiring and cable systems. 8. Where grounding cables cross secondary roads which are not paved, burial depth or design of cable protective covering or both shall prevent damage either to the cables or to the covering from anticipated heavy loads such as mobile cranes or equipment transport vehicles. A safety factor of 1.5 shall be applied to the total loads. 9. Grounding conductors leaving the ground at grade shall be protected as follows: a. Conductors except those used for lightning protection shall be protected by rigid metal conduit or pipe sleeves where they are extended above grace. Lightning protection conductors shall be protection conductors shall be protected by non-metallic conduit sleeves. b. Sleeves shall extend a minimum of 6 in. below grade and 10 in. above grade. c. Metal sleeves shall be encased in concrete 3 in. thick all around. d. Concrete encasement shall extend 6 in. above grade. e. Non-metallic sleeves shall be rigidly heavy wall polyvinyl chloride or high density polyethylene conduit. f. Sleeves not required within switch or transformer yards or under elevated substations. Bonding and Grounding Connections All conductors connection to structures and equipment shall be made above ground as follows: a. Conductors shall be installed in one length between aboveground connection points. b. Single cable lengths shall also be installed between aboveground connection points and grounding electrodes or taps on common ground return cables. c. If splices or taps are required on underground runs, they shall be made with tool-installed compression connectors or by brazing or welding. d. Screw-type solderless connectors shall not be used underground. e. Splices or taps in underground runs shall be buried.

Page 5 of 23 On equipment, conductor connections which are regularly disconnected for maintenance of the equipment shall be made with screw type solderless connectors. Other connections shall be made solderless connectors or by brazing or welding. All welded connections shall be made by a welding process equivalent to Cadweld or Thermoweld. Grounds 1. Grounds shall meet the resistances to earth specified herein throughout the year considering seasonal variation in soil conditions. 2. Buried grounding conductors serving as grounds shall have a length of not less than 25 ft. 3. Grounding Electrodes. If permanently installed and located within a reasonable distance of the equipment or structure to be grounded, the following may be used as grounding electrodes: - Underground metallic water piping if buried portion is greater than 10 ft. length. - Large underground metallic objects in intimate contact with earth such as pile casings or building frames. 4. Artificial grounding electrodes shall consist of driven rods and shall be as follows: a. Rods shall be copper clad steel 1 equivalent to Copperweld and shall have a minimum diameter of 5.8 in. b. Top of rods shall be at least 18 inches below grade. c. A grounding conductor shall connect the top of each rod to an accessible aboveground connection point. The connection point may be located on the structure or equipment to be grounded or on a nearby permanent structure to serve as a tie-in point for other grounding conductors. At tie-in points, conductors from rods shall be identified with corrosion resistant metal bands to facilitate their removal for test purposes. d. The grounding conductor shall be connected to the rod by brazing or welding and to the connection points by a screw type solderless connector. e. Rod top and its grounding conductor shall be buried. f. If more than one artificial electrode is connected to a ground system, the electrodes shall be spaced at least 10 ft. apart.

Page 6 of 23 Substation and Generating Station Grounds All grounding electrodes at substations and generating stations shall be interconnected by grounding conductors. If grounding conductors are used in lieu of electrodes, all conductors shall be interconnected. SYSTEM NEUTRAL GROUNDS Ground Resistance Grounds for system neutrals shall have a resistance to earth as follows: For impedance-grounded system (such as low resistance, high resistance, and reactance), the values above apply to the resistance to earth from the grounded side of the impedance, and do not include the impedance which is specified separately. Grounding Conductor Size 1. Grounding conductors used to ground power transmitter or generator neutrals shall have a cross sectional size not less than 32 mm 2 (0.05 in 2, 2-Awg.). In addition, the size shall limit temperature reached by the conductor, when carrying maximum ground fault current for the time allowed by the slowest responsive relay, to the following: a. For insulated conductors, to within the transient temperature for no damage to the insulation. b. For bare conductors: to 250 C if connections to cable are made with pressure connectors; to 450 C rise if connections to cable are brazed or welded. For copper conductor and 26 C ambient, required size is