CARLYLE REFRIGERATION COMPRESSORS

Similar documents
Compressors, Chillers & Condensers

AE R6 December Digital Capacity Control for Copeland Scroll Refrigeration Compressors AE R6

Application Engineering

MDT5N25 & MTD5N40 SERVICE PARTS

WON0502-B INSTALLATION INSTRUCTIONS FOR ELECTRIC FURNACES. Bulletin / March 2013

AFE424 SERVICE PARTS

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

A/C refrigerant system, overview

Diesel Engine Driven Generators Page 1 of 6

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Application Feature Valve Nominal Liquid Capacity R-22 (in tons)*

Air Vantage 500 Kubota

Why and How we Use Capacity Control

300 Series PA Pump and Cooler Assemblies

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

CARRIER REFRIGERATION EQUIPMENT AND PARTS

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

ECOCIAT. Domestic hot water heat recovery unit

PANASONIC TROUBLE SHOOTING GUIDE

TECHNICAL SUPPORT MANUAL 3 Phase Air Conditioner Component R2A3**GHR

INDUSTRIAL DIRECT DRIVEN PISTON COMPRESSORS CL - CH - CK

OPL BASIC. Dosing System for Professional Laundry machines. Contents

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

Panel Mounted Air Conditioners by Dantherm, Inc.

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Accumulators and Receivers

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

Explosion-Proof Electric Unit Heaters

INSTALLATION INSTRUCTIONS

MAYTAG MFD2560HEB NACIONAL E IMPORTACIÓN CABINET BACK

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

4 Posiflow Proportional Solenoid Valves

10ACC WARNING WARNING. Service Literature 10ACC SERIES UNITS

GCS16 GCS20 WARNING CAUTION

HP switch LP switch Discharge thermo Comp. Surface thermo

ILLUSTRATED PARTS LIST XTREME ICE MAKER (1230 SERIES) MODEL NO.

GROENEVELD AUTOMATIC GREASING SYSTEMS

Volkswagen New Beetle 2.0 Liter 4-cyl General, Engine (Engine Code AEG) 17 Engine-Lubrication system (Page GR-17)

PVH131/141 Variable Displacement Piston Pump - 11 Design

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

ELECTRIC MOTOR TEFC OPERATION & MAINTENANCE. meps Approved

Inverter Compressor Technology for Refrigerator. Reciprocating

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

The prevailing force in the field. AIR CONDITIONING SOLUTIONS FOR THE PULP AND PAPER INDUSTRY

MAC-120HE-01 Air-Cooled Chiller

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

PROAIR Water-Cooled Air Conditioner. CR43WC Model INSTRUCTION MANUAL. Rev. E 2013 Pentair Technical Products P/N

Low Profile Unit Cooler

Solenoid valves Type EVU

REMOTE AIR-COOLED CONDENSERS. Installation and Maintenance Data. Models Bulletin H-IM-73A June 2000 Part Number

LOBOY 16 AIR CONDITIONERS

Oil and Coolant Circulating Heating System. Model - OCSM

Installation Instructions

Section M POWER LIFTS

Remote Power Panels with Breakers

T-SERIES Air Conditioners. T70, 3 Ton and 5 Ton Models INSTRUCTION MANUAL. Rev. H 2013 Pentair Equipment Protection P/N

Rotary Screw Compressor. MSM MINI 2, ,5 kw

THERMO KING TRUCK & TRAILER UNIT ALARM CODES THIS DOCUMENT SHOWS ALL CURRENT ALARM CODES FOR THERMO KING TRUCK AND TRAILER UNITS.

Selection & Application Guidelines Performer scroll compressors Single 20 to 110 kw Hz

Electronic, Digital and Mechanical Vibration Switches

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

Valve systems Base plates, according to standard ISO Brochure

Italvibras USA. Operator s Manual

Skills Canada National Competition Instructions and Competition Details 38 Refrigeration and Air Conditioning / Post - Secondary May 27-30,

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

DESIGN STANDARDS SECTION

Series Hose Reels

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

CRN A-F-G-E-HQQE 3x400D 50 HZ

Eurovacuum EV Series. Single Stage Oil Sealed Rotary Vane Pump

Repair Parts List REFRIGERATOR MODEL NUMBER MFI2067AES. When requesting service or ordering parts, always provide the following information:

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

PARTS LIST T30 MODEL 2545 TWO STAGE INDUSTRIAL AIR COMPRESSOR

SSB*H4. Service Literature. SSB*H4 Commercial Air Conditioner

DANGER DANGER. General Information. Safety Is Your Responsibility. Ordering Parts. Contact Information

Flextec 450 PARTS LIST FOR RETURN TO MAIN INDEX

E2 Series Electric Furnaces

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

Circuit Breakers. NRC Series. NRC Series

CRN5-5 A-FGJ-G-E-HQQE 3x230/400 50HZ

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Cooling Capacity CFM in. w.c. (125 Pa)

Line-Mounted Valves L Series

Models: WA182, WA242. Contents. Cabinet Components. Functional Components " Exploded View... 3 " Usage List Control Panel.

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

Assisted lift operated 2/2-way solenoid valves Type EV250B

Drive Technology \ Drive Automation \ System Integration \ Services. DR Motor Common Connection Diagrams

4" SUBMERSIBLE PUMPS

Rotary screw compressors kw 5,5 7, , bar MODULO

OUTDOOR UNIT MODEL NUMBER IDENTIFICATION GUIDE (single phase) ACCESSORIES PART NUMBER IDENTIFICATION GUIDE

Split System Cooling Product Data

TECHNICAL DATA & SERVICE MANUAL SPLIT SYSTEM AIR CONDITIONER INDOOR UNIT: AW52AL AW64AL AW52AL AW64AL /05

AIR-COOLED CONDENSERS Technical Guide

TECHNICAL BROCHURE B5-33GB 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Power Cube Open Source Ecology Page 1. Power Cube. Version 4

Transcription:

GENERAL NOTES on Refrigeration Screw Compressors 05T & 06T Compressors are shipped with service valves attached to the compressor pallet and have blankoff pads bolted over service valve openings. Alternate suction and discharge service valves are available. All 06T screw compressors are suitable for across-the-line or part winding start. Customer is required to hook up terminal plate for applicable voltage. Wiring diagrams and jumpers are included in the compressor terminal box. Compressor part number on nameplate is the same as the package ordering number. All 05T and 06T compressors: a. Are dehydrated and have a dry air holding charge. b. Have no oil charge. Oil must be added to fill the entire oil system from the oil solenoid at compressor back to the oil separator. Carlyle requires the following accessories to protect both 05T and 06T compressors: oil separator oil level switch oil filter housing reverse rotation protection switch oil pressure differential switch Carlyle Electronic Module high pressure switch low pressure switch The 05T Compressor further requires: C-Flange coupling 06T screw compressors provided WITHOUT motor overcurrent protection, which MUST be supplied by the customer. Heinemann calibrated circuit breakers specifically selected for each motor and voltage are a required accessory. All 06T compressor models are UL and CSA approved. The use of authorized overcurrent protection is part of UL recognition. All 06T compressors are provided with a 5K thermistor installed in the compressor motor to monitor the motor temperature. The CEM is required with each 06T to monitor this thermistor. All compressors are painted green. 37

05T (7 mm) SCREW COMPRESSOR Design Duty: Qualified For: Capacities: Economizer: Vi: Configuration: Check Valve: Oil Filter: Motor Type: Commercial Refrigeration HCFC Refrigeration Duty HFC Refrigeration Duty R-/07C Water Cooled Duty R-3a Air Cooled Duty cfm @ 60 Hz 33 39 9 5 65 78 88 m3 /hr @ 50 Hz Optional on all models Dual Vi Option Open Drive Integral External External 38

OPEN DRIVE MODELS - For All Temperature Ranges With Service Valves DISPLACEMENT (CFM) MODEL NO 750 RPM ( pole) 3500 RPM ( pole) MOTOR HP APPROX SHIP WEIGHT (kg) 05TRQ033Z3EA-A00 33 65 N/A 9 05TRQ039Z3EA-A00 39 78 N/A 9 05TRQ0Z3EA-A00 88 N/A 9 05TRQ08Z3EA-A00 8 N/A N/A 9 05TRQ05Z3EA-A00 5 N/A N/A 9 NOTE: APPLICATION LIMITS. R-3a - Medium temperature - Air Conditioning R- - Low temperature - Medium temperature - Air Conditioning R-0A/R-507 - Low temperature - Medium temperature ACCESSORIES FOR 05T MODELS 05T COUPLING PACKAGE COUPLING PKG MOTOR SHAFT DIAMETER (in.) POLE MOTOR 750 Rpm @ 60 Hz 50 Rpm @ 50 Hz NEMA Frame Hp Size Hp POLE MOTOR 3500 Rpm @ 60 Hz 3000 Rpm @ 50 Hz NEMA Frame Size APPROX. SHIP. WT (kg) 8TA0868B 5/8 5, 0 5TC, 56TC 30 86TC 5 8TA0869B 7/8 5, 30 8TC, 86TC 0, 50 60, 75 3TSC, 36TSC, 36TSC, 365TSC 8TA0870B /8 0, 50 3TC, 36TC N/A N/A 5 5 05T C-FLANGE PACKAGE C-FLANGE PKG POLE MOTOR 750 Rpm @ 60 Hz 50 Rpm @ 50 Hz NEMA Frame Hp Size Hp POLE MOTOR 3500 Rpm @ 60 Hz 3000 Rpm @ 50 Hz NEMA Frame Size APPROX. SHIP. WT (kg) 0TA099 5, 0, 35, 30 5TC, 56TC, 8TC, 86TC N/A N/A 5 0TA0930 5, 30 8TC, 86TC N/A 60, 75 N/A 5 0TA093 N/A N/A 0, 50 60, 75 86TC, 3TSC, 6TSC, 36TSC, 365TSC 5 39

06T SCREW COMPRESSOR 06T Model Number Significance CAPACITY (Btu/Hr) @ 60 Hz Refrigerant R- R-507/0A R- R-507/0A R-3a Conditions -5/0/65-5/0/65 0/0/65 0/0/65 5/30/65 06T**033 5,000 70,900 3,500 3,00 7,900 06T**039 6,700 86,00 6,000 75,000 56,800 06T**0 7,00 98,900 8,800 99,000 77,700 06T**08 80,00,000 03,00,00 9,300 06T**05 9,900 6,00 33,00 53,700,800 06T**065 3,900 56,00 9,500 38,00 8,00 06T**078 0,00 9,000 35,300 385,700 3,00 06T**088 59,800 8,700 00,900 36,300 387,500 Economized ( F). 0

COMPRESSOR PHYSICAL DIMENSIONS

LOW TEMPERATURE DUTY - Semi-Hermetic With Service Valves MODEL NO. VOLTAGE MOTOR 3 PHASE HP 60 HZ 50 HZ 06TRC033BEA-A00 60 00 FEA-A00 08/30 00 5 66 CEA-A00 575-06TRD039BEA-A00 60 00 FEA-A00 08/30 00 0 7 CEA-A00 575-06TRD0BEA-A00 60 00 FEA-A00 08/30 00 0 7 CEA-A00 575-06TRE08BEA-A00 60 00 FEA-A00 08/30 00 5 77 CEA-A00 575-06TRE05BEA-A00 60 00 FEA-A00 08/30 00 5 77 CEA-A00 575-06TRF065BEA-A00 60 00 FEA-A00 08/30 00 30 8 CEA-A00 575-06TRG078BEA-A00 60 00 FEA-A00 08/30 00 35 8 CEA-A00 575-06TRH088BEA-A00 60 00 FEA-A00 08/30 00 0 8 CEA-A00 575-06TRK08BEA-A00 NOTE: 50Hz Applications Only APPROX. SHIP. WEIGHT (kg) n/a 00 50 86 NOTE: APPLICATION LIMITS. R-3a - Medium temperature - Air Conditioning R- - Low temperature R-0A/R-507 - Low temperature 06TRK model satisfactory for use on high temp, medium temp and low temp applications.

MEDIUM/HIGH TEMPERATURE DUTY - Semi-Hermetic With Service Valves MODEL NO. VOLTAGE 3 PHASE 60 HZ 50 HZ MOTOR HP APPROX. SHIP. WEIGHT (kg) 06TAD033BEA-A00 60 00 FEA-A00 08/30 00 0 6 CEA-A00 575-06TAE039BEA-A00 60 00 FEA-A00 08/30 00 5 7 CEA-A00 575-06TAF0BEA-A00 60 00 FEA-A00 08/30 00 30 7 CEA-A00 575-06TAF08BEA-A00 60 00 FEA-A00 08/30 00 30 76 CEA-A00 575-06TAG05BEA- A00 60 00 FEA-A00 08/30 00 35 76 CEA-A00 575-06TAG065BEA- A00 60 00 FEA-A00 08/30 00 35 80 CEA-A00 575-06TAH078BEA-A00 60 00 FEA-A00 08/30 00 0 8 CEA-A00 575-06TAK088BEA-A00 60 00 FEA-A00 08/30 00 50 87 CEA-A00 575 - NOTE: APPLICATION LIMITS. R- - Medium temperature - Air Conditioning (High Temperature) R-0A/R-507 - Medium temperature 3

05T/06T REFRIGERATION COMPRESSOR ACCESSORIES ELECTRONIC PHASE MONITOR (REVERSE ROTATION PROTECTION) ( Package Per Compressor Recommended) PART NO QTY/PKG WEIGHT (kg) USAGE P5-0090.5 ALL 05/6T compressors. Protects screw compressor from reverse rotation by monitoring 3-phase input power to compressor motor. Will not let compressor start if sequence is incorrect.. This phase monitor will not operate with a variable speed drive inverter. 3. May be used in place of reverse rotation switch; () per compressor. RUBBER ISOLATION MOUNTS ( Package Per Compressor Recommended) PART NO QTY/PKG WEIGHT (kg) USAGE KA75KR00 0.5 ALL 05/6T compressors MUFFLERS ( Per Compressor Required) PART NO QTY/PKG WEIGHT (kg) INLET/OUT LENGTH USAGE LM0HH6 3-5/8" 9-3/" All 05/6T compressor OIL SEPARATORS ( Per Rack Required) PART NO MOUNTING LINE SIZE WEIGHT (kg) DIA USAGE KH3ZZ30 VERTICAL -/8" 66 " Single Comp. KH3ZZ VERTICAL -5/8" 0 " Multiple Comp.. Oil Separators supplied with multiple sight glasses to view oil level.. Oil Separators has adapter fitting at bottom to connect KH3LB00 Oil Level Float Switch.

05T/06T REFRIGERATION COMPRESSOR ACCESSORIES OIL LEVEL SWITCH ( Per Oil Separator Required) PART NO QTY/PKG WEIGHT (kg) USAGE HK3LB00 0.5 On vertical oil separators NOTE:. Protects compressor against loss of oil in Oil Separator. Screws into bottom. HEATER FOR OIL SEPARATOR / OIL RESERVOIR ( Per Oil Separator Recommended) ELECTRICAL CHARACTERISTICS PART NO QTY/PKG WEIGHT (kg) VOLTS WATTS HK38KN007 0.5 5/30 500 NOTE:. Heater applied to oil separator to keep refrigerant from accumulating in it during off cycles. See application guide for application requirements. AIR-COOLED OIL COOLERS (See Application Guide for Requirements) ELECTRICAL CHARACTERISTICS PART NO NO OF COMPS@ LOAD WEIGHT (kg) VOLTS - PH HZ KH5ZZ8 3 5/30 V - PH 60/50 HZ KH5ZZ8 3 57 5/30 V - PH 60/50 HZ KH5ZZ83 9 5/30 V - PH 60/50 HZ KH5ZZ8 5 98 5/30 V - PH 60/50 HZ OIL FILTER HOUSING ASSEMBLY ( Per Rack Required) PART NO QTY/PKG WEIGHT (kg) CONNECTION TYPE USAGE KH8MG00 7/8" Sweat All 05/6T Compressors. Oil Housing which allows replacement of filter cartridge.. Filter Housing assembly includes () 3 micron filter cartridge. 3. () per rack recommended. 5

05T/06T REFRIGERATION COMPRESSOR ACCESSORIES OIL FILTER CARTRIDGE PART NO QTY/PKG WEIGHT (kg) USAGE KH39MG00 0.5 Replacement Cartridge for KH8MG00 housing NOTE:. Carlyle recommends (3) cartridges be left at the job site per oil filter housing. Several changeouts will be necessary before the system is free of contaminant. If the job is a remodel, more changeouts may be necessary.. Each cartridge is supplied with () filter housing O ring. DESUPERHEATING VALVES ( Per Compressor for R- <-3 C & R-0A/R507 <-3 C SST Systems) PART NO QTY/PKG WEIGHT (kg) SIZE USAGE EA0ZD00 ton All 05/6T Compressors EA0ZD00.5 ton All 05/6T Compressors EA0ZD030 ton All 05/6T Compressors EA0ZD050 3 ton All 05/6T Compressors EA0ZD00 5 ton All 05/6T Compressors SOLENOID COILS - FOR UNLOADING AND Vi CONTROL ( Per 06TA Compressor Required) ( Per 05TR/6TR Compressor Required) PART NO QTY/PKG WEIGHT (kg) ELECTRICAL USAGE EF9ZE0 0.5 0--50/60 All 05/6T Compressors EF9ZE0 0.5 08/0--50/60 All 05/6T Compressors EF9ZE0 0.5 --50/60 All 05/6T Compressors. Solenoid Coil operates either capacity control unloading mechanism or variable volume (Vi) control.. 06TR Models require () per compressor, 06TA models require () per compressor. CARLYLE ELECTRONIC MODULE (CEM) ( Per Compressor Required) PART NO QTY/PKG WEIGHT (kg) ELECTRICAL USAGE 3TA0796B 0.5 0/0--60, 00/00--50 All 05/6T Compressors. Module uses () 5K Thermistors, () embedded in motor windings and () strapped on discharge line (thermistor purchased separately.). The modules control motors and discharge cooling and acts as a safety for overheating protection. 6

05T/06T REFRIGERATION COMPRESSOR ACCESSORIES 5K THERMISTOR ( Per Compressor Required) PART NO QTY/PKG WEIGHT (kg) ELECTRICAL USAGE HH79NZ065 0.5 5/0--60 All 05/6T Compressors NOTE: One required per compressor for use with CEM to monitor discharge temperature. MOTOR COOLING VALVES ( Per Compressor Required) PART NO QTY/PKG WEIGHT (kg) EVAP SIZE USAGE EF8BZ007 0.5. All 05/6T Compressors NOTE: Used for motor and discharge gas cooling of screw compressors. SOLENOID COILS FOR MOTOR COOLING VALVES ( Per Compressor Required) PART NO QTY/PKG WEIGHT (kg) ELECTRICAL USAGE P50-XV0D 0.5 0--50/60 All 05/6T Compressors P50-XV08D 0.5 08/0--50/60 All 05/6T Compressors P50-XV0D 0.5 --50/60 All 05/6T Compressors REVERSE ROTATION PROTECTION SWITCH ( Per Compressor Required) PART NO QTY/PKG WEIGHT (kg) USAGE HK0CB00 All 05/6T Compressors NOTE: Protects screw compressor from reverse rotation. 7

05T/06T REFRIGERATION COMPRESSOR ACCESSORIES OIL PRESSURE DIFFERENTIAL SWITCH ( Per Compressor Required) PART NO QTY/PKG WEIGHT (kg) CONNECTION TYPE VOLTAGE INPUT USAGE HH79NZ065 0.5 /" FLARE 5 or 30 ALL 05/6T compressors. Senses oil differential between discharge pressure and oil feed to the compressor.. Switch setting is for cutout when differential pressure above (5 psid) and has a 30 second time delay. OIL FILTER DIFFERENTIAL SWITCH PART NO QTY/PKG WEIGHT (kg) CONNECTION TYPE VOLTAGE INPUT USAGE HK06CA05 /" FLARE 5 or 30 ALL 05/6T compressors ( Per Oil System Recommended). Senses oil differential across filters.. Switch setting is for cutout when differential pressure exceeds 5 psid and has a 30 second time delay. SUCTION AND DISCHARGE SERVICE VALVE PACKAGES PART NO QTY/PKG WEIGHT (kg) SIZE ODF USAGE 06TA66000-5/8" ALL 05/6T compressors 05T/06T 33, 39,, 8, 5 CFM 06TA66000-3/8" ALL 05/6T compressors 05T/06T 33, 39,, 8, 5 CFM 06TA660003 -/8" ALL 05/6T compressors 05T/06T 33, 39,, 8, 5 CFM 06TA680008-5/8" ALL 05/6T compressors 05T/06T 65, 78, 88 CFM. All service Valves are bolt, -/ square bolt spacing. Service Valve Package contains () service valve, () gasket, and () metric hex head cap screws (M x.75 x 60mm).. These Service Valve packages (except 06TA68008) are the same as the respective 06D/E packages except the mounting bolts have metric threads. ECONOMIZER SERVICE VALVE PART NO QTY/PKG WEIGHT (kg) SIZE ODF USAGE 06TA66000 7/8 ALL 05/6T compressors. () 06TA66000 package is supplied with each compressor.. All Economizer Service Valve contain () Rotalock * valve, () O-ring, () seal, and () connection fitting. 8

06T REFRIGERATION COMPRESSOR ACCESSORIES CALIBRATED CIRCUIT BREAKERS ( Per 06T Compressor) COMPRESSOR MODEL USAGE 06TRC033BEA-A00 FEA-A00 CEA-A00 06TRD039BEA-A00 FEA-A00 CEA-A00 06TRD0BEA-A00 FEA-A00 CEA-A00 06TRE08BEA-A00 FEA-A00 CEA-A00 06TRE05BEA-A00 FEA-A00 CEA-A00 06TRF065BEA-A00 FEA-A00 CEA-A00 06TRG078BEA-A00 FEA-A00 CEA-A00 06TRH088BEA-A00 FEA-A00 CEA-A00 VOLTAGE 3 PHASE QTY/PKG WEIGHT (kg) CIRCUIT BREAKER 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 3 3 3 3 3 HH83XA63 HH83XB356 HH83XA60 HH83XA HH83XB336 HH83XA6 HH83XA HH83XB336 HH83XA6 HH83XA6 HH83XC509 HH83XA69 HH83XA6 HH83XC509 HH83XA69 HH83XA7 HH83XC573 HH83XB67 HH83XA76 HH83XC57 HH83XB68 HH83XA76 HH83XC575 HH83XB69 06TRK08BEA-A00 00-3-50 HH83XA77. Circuit breaker selections are based on across-the-line start.. Over current protection required per General Note. 3. Heinemann circuit breaker not required with 05T compressor. 9

06T REFRIGERATION COMPRESSOR ACCESSORIES CALIBRATED CIRCUIT BREAKERS COMPRESSOR MODEL USAGE VOLTS-PH-HZ QTY/PKG WEIGHT (kg) CIRCUIT BREAKER 06TAD033BEA-A00 FEA-A00 CEA-A00 06TAE039BEA-A00 FEA-A00 CEA-A00 06TAF0BEA-A00 FEA-A00 CEA-A00 06TAF08BEA-A00 FEA-A00 CEA-A00 06TAG05BEA-A00 FEA-A00 CEA-A00 06TAG065BEA-A00 FEA-A00 CEA-A00 06TAH078BEA-A00 FEA-A00 CEA-A00 06TAK088BEA-A00 FEA-A00 CEA-A00 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 60-3-60 & 00-3-50 30-3-60 & 00-3-50 6 6 6 HH83XA HH83XB336* or HH83XB65 HH83XA6 HH83XA6 HH83XC509 HH83XA69 HH83XA5 HH83XC539 HH83XA30 HH83XA5 HH83XC539 HH83XA30 HH83XA57 HH83XC53 HH83XA53 HH83XA75 HH83XC57 HH83XB68 HH83XA76 HH83XC575 HH83XB69 HH83XA77 HH83XC576 HH83XB60 *These breakers are supplied without compression lugs. Customer must provide connectors or use our Power Terminal Parts Connectors for HH83XB Circuit Breakers shown below.. Circuit breaker selections are based on across-the-line start.. Overcurrent protection required per General Note. 3. Heinemann circuit breaker not required with 05T compressor. POWER TERMINAL PARTS CONNECTORS FOR HH83XB CIRCUIT BREAKER PART NO APPROX SHIP WEIGHT (kg) USAGE 06EA6605 0.5 # - # Wire 06EA66053 0.5 # Wire HH83XB series circuit breakers require customer supplied power wire connections at circuit breaker. Kit includes ring terminal, cap screws and lock washers. Not required for XA, XC, C or B series circuit breakers. TERMINAL PARTS PACKAGES PART NO QTY/PKG WEIGHT (kg) USE WITH USAGE 06EA9003 0.5 #6 Wire All 06T Compressors 06EA9000 0.5 # Wire All 06T Compressors 06EA900 0.5 # Wire All 06T Compressors 06EA900 0.5 #/0 Wire All 06T Compressors Package Contents: (6) Ring Terminal to connect power wiring to compressor terminal studs, plus (3) spare (-hole) jumper bars. 50