1 Drive Technology \ Drive Automation \ System Integration \ Services DR Motor Common Connection Diagrams Edition 06/2010 9PD0058 / US

2 SEW-EURODRIVE Driving the world

3 Table of Contents Overview... 5 Important notes... 6 Safety notes... 6 Motor nameplate... 6 Connecting the brake from the terminal block... 7 /... 7 BSR (R76 only)... 7 R Brake Voltage Supplied from the Motor... 9 / - Motor = 230V; Brake = 230V... 9 / - Motor = 460V; Brake = 230V / - Motor = 460V; Brake = 460V BSR - Motor = 230V; Brake = 230V BSR - Motor = 460V; Brake = 230V BSR - Motor = 460V; Brake = 460V R Brake Voltage Supplied from the Motor / - Motor = 460V; Brake = 230V / - Motor = 460V; Brake = 460V BSR - Motor = 460V; Brake = 230V BSR - Motor = 460V; Brake = 460V R Brake Voltage Supplied from the Motor / - Motor = low ( ) voltage; Brake = low ( ) voltage / - Motor = high ( ) voltage; Brake = low ( ) voltage / - Motor = high ( ) voltage; Brake = high ( ) voltage BSR - Motor = low ( ) voltage; Brake = low ( ) voltage BSR - Motor = high ( ) voltage; Brake = low ( ) voltage BSR - Motor = high ( ) voltage; Brake = high ( ) voltage BSG and R brake connection DR Motor common connection diagrams 3

4 DR Motor common connection diagrams

5 Overview 1 Overview This document details common connection diagrams for DR motor. This is not a replacement for the Operating Instructions. Always refer to the Operating Instructions for safety and installation information. Additional resources and information for DR motor BE brakes can be found at under the Technical Notes tab. There are specific instances when the brake voltage can be tapped directly from the motor's terminal block. The advantage of brake systems wired in this way is when power is applied to the motor, the brake releases (requiring no additional brake supply wiring). The brake can be wired to the motor terminal block under the following conditions: a single speed motor, the motor is started and run across the line, and the brake voltage is equal to either the low or high motor voltage. The brake must be powered separately if the brake voltage does not equal the low or high motor voltage, the motor is powered by an inverter, or electronic soft start DR Motor common connection diagrams 5

6 Important notes 2 Important notes 2.1 Safety notes Refer to the Operating Instructions for safety and installation information. The latest version can be found at Installation, startup and service work may only be performed by trained personnel observing applicable accident prevention regulations and operating instructions. 2.2 Motor nameplate Refer to the motor nameplate for information that describes the motor data. Some of the important fields related to the connection are listed below. â Type S.O. HP rpm V DRE80M4BE05/FF V / 460V HZ 60 NEMA Conn A 2.9 / 1.44 Code 82.5 Nom Eff % Dia R S.F. 1.0 Duty CONT Design Letter Ins Maximum 1740 Class B Ambient 40 C Brake V Torque lb-in Control E TEFC 3PH Motor Voltage - Lists the motor voltage and configuration. Example: 230V / 460V. Connection Type - Lists the basic type of connection indicating the type of internal motor windings,,,, etc. Example: R76. This value may also be followed by a series of letters and/or numbers. Brake Voltage - Lists the brake voltage required to operate the brake. Example: 460V. Brake Control - Lists the brake control type. Example:,, BSR, etc. These maybe followed by additional characters DR Motor common connection diagrams

7 Important notes 2.3 Connecting the brake from the terminal block / When connecting the supply power from the motor terminal block to the brake rectifier, follow the specifications below. Connecting wire is to be AWG14, MTW, 600V, 105 C temperature rating and black color. The recommended ring terminals are manufactured by Thomas & Betts or equivalent. Follow the manufacturer s recommendations for installation procedures. DR Motor Frame Size Wire Length Thomas & Betts Ring Terminal Thomas & Betts Crimp Tool DR RB14-8 DR RB14-10 DR RB WT2000 DR RB BSR (R76 only) When connecting the jumper wire between the 2-pole terminal block for the SR relay and the motor terminal block, follow the specifications below. Connecting wire is to be MTW, 600V, 105 C temperature rating and black color. Maximum length 8", trimmed to fit. The recommended ring terminals are manufactured by Thomas & Betts or equivalent. Follow the manufacturers recommendations for installation procedures. DR Motor Frame Size AWG Thomas & Betts Ring Terminal Thomas & Betts Crimp Tool DR RB14-8 DR RB14-10 WT2000 DR RB DR Motor common connection diagrams 7

8 R76 3 R76 Connection Type R76 Single Speed, Dual Voltage Example: 230V / 460V Low Voltage High Voltage W2 (T6) U2 (T4) V2 (T5) W3 (T9) W2 (T6) U3 (T7) U2 (T4) V3 (T8) V2 (T5) U3 (T7) U1 (T1) V3 (T8) V1 (T2) W3 (T9) W1 (T3) U1 (T1) V1 (T2) W1 (T3) [5] L1 L2 L3 Example: 230V [5] L1 L2 L3 Example: 460V Arrangement of terminal links for connection No terminal links required for connection W2 U2 V2 T6 T4 T5 U1 U3 V1 V3 W1 W3 T1 T7 T2 T8 T3 T9 U1 V1 T1 T2 W2/W3 U2/U3 T6/T9 T4/ T5/T8 T7 W1 T3 V2/V3 [5] [5] Terminal link Terminal board Terminal stud [5] Voltage supply (Customer connection) Flange nut VOLTAGE CHANGE Three wires must be relocated and terminal links added to change from high to low voltage. The wires designated U3 (T7), V3 (T8) and W3 (T9) must be reconnected and terminal links added as shown in the diagram. Changing from low to high voltage is carried out in reverse order. In both cases, the supply voltage is connected to U1 (T1), V1 (T2) and W1 (T3). The direction of rotation is changed by exchanging two wires DR Motor common connection diagrams

9 R Brake Voltage Supplied from the Motor / - Motor = 230V; Brake = 230V Brake Control: /. Motor configured for low voltage. Brake voltage matches the low motor voltage. Example: 230V / 460V motor configured for 230V ( ) supply voltage Brake voltage is 230V (normal reaction time)* W2 (T6) U2 (T4) V2 (T5) U3 (T7) U1 (T1) V3 (T8) V1 (T2) W3 (T9) W1 (T3) L1 L2 L3 Example: 230V _ R76H US * / Rapid Reaction Time DC AC V AC XX Motor terminal board Customer supplied contacts Brake coil Brake supply voltage - blue - red - white 2010 DR Motor common connection diagrams 9

10 R / - Motor = 460V; Brake = 230V Brake Control: /. Motor configured for high voltage. Brake voltage matches the low motor voltage. Example: 230V / 460V motor configured for 460V ( ) supply voltage Brake voltage is 230V (normal reaction time)* W2 (T6) W3 (T9) U2 (T4) U3 (T7) V2 (T5) V3 (T8) U1 (T1) V1 (T2) W1 (T3) L1 L2 L3 Example: 460V _ R76I US * / Rapid Reaction Time DC AC V AC XX Motor terminal board Customer supplied contacts Brake coil Brake supply voltage - blue - red - white DR Motor common connection diagrams

11 R / - Motor = 460V; Brake = 460V Brake Control: /. Motor configured for high voltage. Brake voltage matches the high motor voltage. Example: 230V / 460V motor configured for 460V ( ) supply voltage Brake voltage is 460V (normal reaction time)* W2 (T6) W3 (T9) U2 (T4) U3 (T7) V2 (T5) V3 (T8) U1 (T1) V1 (T2) W1 (T3) L1 L2 L3 Example: 460V _ R76J US * / Rapid Reaction Time DC AC V AC XX Motor terminal board Customer supplied contacts Brake coil Brake supply voltage - blue - red - white 2010 DR Motor common connection diagrams 11

12 R BSR - Motor = 230V; Brake = 230V Brake Control: BSR. Motor configured for low voltage. Brake voltage matches the low motor voltage. Example: 230V / 460V motor configured for 230V ( ) Brake voltage is 230V [5] U2 (T4) V2 (T5) U3 (T7) V3 (T8) W3 (T9) U1 (T1) V1 (T2) W1 (T3) [6] W2 (T6) * L1 L2 L3 Example: 230V *refer to section _ R76C US Motor terminal board SR current relay Supply leads [5] Terminal strip Brake coil [6] Wire end from stator winding - blue - red - white DR Motor common connection diagrams

13 R BSR - Motor = 460V; Brake = 230V Brake Control: BSR. Motor configured for high voltage. Brake voltage matches the low motor voltage. Example: 230V / 460V motor configured for 460V ( ) Brake voltage is 230V U2 (T4) V2 (T5) W3 (T9) U3 (T7) V3 (T8) [5] U1 (T1) V1 (T2) W1 (T3) [6] W2 (T6) * L1 L2 L3 Example: 460V *refer to section _ R76D US Motor terminal board SR current relay Supply leads [5] Terminal strip Brake coil [6] Wire end from stator winding - blue - red - white 2010 DR Motor common connection diagrams 13

14 R BSR - Motor = 460V; Brake = 460V Brake Control: BSR. Motor configured for high voltage. Brake voltage matches the high motor voltage. Example: 230V / 460V motor configured for 460V ( ) Brake voltage is 460V U2 (T4) V2 (T5) W3 (T9) U3 (T7) V3 (T8) [5] U1 (T1) V1 (T2) W1 (T3) [6] W2 (T6) * L1 L2 L3 Example: 460V *refer to section _ R76E US Motor terminal board SR current relay Supply leads [5] Terminal strip Brake coil [6] Wire end from stator winding - blue - red - white DR Motor common connection diagrams

15 V3/T8 W3/T9 V3/T8 W3/T9 R72 4 R72 Connection Type R72 Single Speed, Dual Voltage Example Voltage: 230V / 460V Low voltage High voltage V3 (T8) V2 (T5) W3 (T9) W2 (T6) U3 (T7) U2 (T4) V3 (T8) V2 (T5) W3 (T9) W2 (T6) U3 (T7) U2 (T4) V4 (T11) W4 (T12) U4 (T10) V4 (T11) W4 (T12) U4 (T10) U1 (T1) V1 (T2) W1 (T3) U1 (T1) V1 (T2) W1 (T3) [5] L1 L2 L3 [5] L1 L2 L3 Example: 230V Example: 460V Arrangement of terminal links for connection Arrangement of terminal links for connection V2/T5 U3/T7 V2/T5 U3/T7 T1 U2/T4 V4/T11 V1/T1 U4/T10 U2/T4 [6] V4/T11 V1/T1 V1/T2 W1/T3 U4/T10 [6] V1/T2 W1/T3 [5] [5] Terminal link Terminal board Terminal stud [5] Voltage supply (Customer connection) Flange nut [6] Wiring designation plate 2010 DR Motor common connection diagrams 15

16 R Brake Voltage Supplied from the Motor / - Motor = 460V; Brake = 230V Brake Control: /. Motor configured for high voltage. Brake voltage matches the low motor voltage. Example: 230V / 460V motor configured for 460V ( ) Brake voltage is 230V (normal reaction time)* V3 (T8) V2 (T5) V4 (T11) U1 (T1) W3 (T9) W2 (T6) W4 (T12) V1 (T2) U3 (T7) U2 (T4) U4 (T10) W1 (T3) L1 L2 L3 Example: 460V * / Rapid Reaction Time DC AC V AC XX Motor terminal board Customer supplied contacts Supply leads Brake supply voltage - blue - red - white DR Motor common connection diagrams

17 R / - Motor = 460V; Brake = 460V Brake Control: /. Motor configured for high voltage. Brake voltage matches the high motor voltage. Example: 230V / 460V motor configured for 460V ( ) Brake voltage is 460V (normal reaction time)* V3 (T8) V2 (T5) V4 (T11) U1 (T1) W3 (T9) W2 (T6) W4 (T12) V1 (T2) U3 (T7) U2 (T4) U4 (T10) W1 (T3) L1 L2 L3 Example: 460V * / Rapid Reaction Time DC AC V AC XX Motor terminal board Customer supplied contacts Supply leads Brake supply voltage - blue - red - white 2010 DR Motor common connection diagrams 17

18 R BSR - Motor = 460V; Brake = 230V Brake Control: BSR. Motor configured for high voltage. Brake voltage matches the low motor voltage. Example: 230V / 460V motor configured for 460V ( ) Brake voltage is 230V V3 (T8) W3 (T9) U3 (T7) V2 (T5) W2 (T6) U2 (T4) V4 (T11) W4 (T12) U4 (T10) U1 (T1) V1 (T2) W1 (T3) L1 L2 L3 Example: 460V _ R72-1D US Motor terminal board SR current relay Supply leads Brake coil - blue - red - white DR Motor common connection diagrams

19 R BSR - Motor = 460V; Brake = 460V Brake Control: BSR. Motor configured for high voltage. Brake voltage matches the high motor voltage. Example: 230V / 460V motor configured for 460V ( ) Brake voltage is 460V V3 (T8) W3 (T9) U3 (T7) V2 (T5) W2 (T6) U2 (T4) V4 (T11) W4 (T12) U4 (T10) U1 (T1) V1 (T2) W1 (T3) L1 L2 L3 Example: 460V _ R72-2 US Motor terminal board Supply leads SR current relay - blue - red - white 2010 DR Motor common connection diagrams 19

20 R13 5 R13 Connection Type R13 Single Speed, Dual Voltage Example voltages: Low voltage 208V 220V 230V 266V 330V High voltage 360V 380V 400V 460V 575V Low voltage High voltage W2 (T6) U2 (T4) V2 (T5) W2 (T6) U2 (T4) V2 (T5) U1 (T1) V1 (T2) W1 (T3) U1 (T1) V1 (T2) W1 (T3) [5] L1 L2 L3 [5] L1 L2 L3 Arrangement of terminal links with connection Arrangement of terminal links with connection Motor size DR.71-DR.225: W2 (T6) (T4) U2 V2 (T5) U1 U1 V1 (T1) (T2) V1 W1 (T1) (T2) W1 (T3) (T3) [5] [5] Terminal link Terminal board Terminal stud [5] Voltage supply (Customer connection) Flange nut DR Motor common connection diagrams

21 R Brake Voltage Supplied from the Motor / - Motor = low ( ) voltage; Brake = low ( ) voltage Brake Control: /. Motor configured for low voltage. Brake voltage matches the low motor voltage. Example: 230V / 400V motor configured for 230V ( ) Brake voltage is 230V (normal reaction time) W2 (T6) U2 (T4) V2 (T5) U1 (T1) V1 (T2) W1 (T3) L1 L2 L _ R13G US * / Rapid Reaction Time DC AC V AC XX Brake coil Customer supplied contacts Terminal board Brake supply voltage - blue - red - white 2010 DR Motor common connection diagrams 21

22 R / - Motor = high ( ) voltage; Brake = low ( ) voltage Brake Control: /. Motor configured for high voltage. Brake voltage matches the low motor voltage. Example: 330V / 575V motor configured for 575V ( ) Brake voltage is 330V (normal reaction time) W2 (T6) U2 (T4) V2 (T5) U1 (T1) V1 (T2) W1 (T3) L1 L2 L _ R13J US * / Rapid Reaction Time DC AC V AC XX Brake coil Customer supplied contacts Terminal board Brake supply voltage - blue - red - white DR Motor common connection diagrams

23 R / - Motor = high ( ) voltage; Brake = high ( ) voltage Brake Control: /. Motor configured for high voltage. Brake voltage matches the high motor voltage. Example: 266V / 460V motor configured for 460V ( ) Brake voltage is 460V (normal reaction time) W2 (T6) U2 (T4) V2 (T5) U1 (T1) V1 (T2) W1 (T3) L1 L2 L _ R13H US * / Rapid Reaction Time DC AC V AC XX Brake coil Customer supplied contacts Terminal board Brake supply voltage - blue - red - white 2010 DR Motor common connection diagrams 23

24 R BSR - Motor = low ( ) voltage; Brake = low ( ) voltage Brake Control: BSR. Motor configured for low voltage. Brake voltage matches the low motor voltage. Example: 230V / 400V motor configured for 230V ( ) Brake voltage is 230V W2 (T6) U2 (T4) V2 (T5) U1 (T1) V1 (T2) W1 (T3) L1 L2 L _ R13B US Brake coil SR Current relay Terminal board - blue - red - white DR Motor common connection diagrams

25 R BSR - Motor = high ( ) voltage; Brake = low ( ) voltage Brake Control: BSR. Motor configured for high voltage. Brake voltage matches the low motor voltage. Example: 330V / 575V motor configured for 575V ( ) Brake voltage is 330V W2 (T6) U2 (T4) V2 (T5) U1 (T1) V1 (T2) W1 (T3) L1 L2 L _ R13E US Brake coil SR Current relay Terminal board - blue - red - white 2010 DR Motor common connection diagrams 25

26 R BSR - Motor = high ( ) voltage; Brake = high ( ) voltage Brake Control: BSR. Motor configured for high voltage. Brake voltage matches the high motor voltage. Example: 266V / 460V motor configured for 460V ( ) Brake voltage is 460V W2 (T6) U2 (T4) V2 (T5) U1 (T1) V1 (T2) W1 (T3) L1 L2 L _ R13C US Brake coil SR Current relay Terminal board - blue - red - white DR Motor common connection diagrams

27 BSG and R brake connection 6 BSG and R brake connection Brake control system BSG BSG Brake control system R Connecting to the terminal board of the motor is not permitted. V AC V DC XX BN / BK BN / BK XX Brake coil Voltage relay UR 11/15 UR11 (42-150V) = BN UR15 ( V) = BK Brake voltage supply - blue - red - white BK - black BN - brown 2010 DR Motor common connection diagrams 27

28 DR Motor common connection diagrams

29

30 SEW-EURODRIVE Driving the world With a global presence that offers responsive and reliable solutions. Anywhere. With drives and controls that automatically improve your productivity. With comprehensive knowledge in virtually every branch of industry today. With industry-leading training and 24-hour technical support, nationwide. SEW-EURODRIVE Driving the world With a worldwide service network that is always close at hand. With uncompromising quality that reduces the cost and complexity of daily operations. With innovative technology that solves problems today. With online information and software updates, via the Internet, available around the clock. SEW-EURODRIVE... Wherever you are, we are North America: Midwest Region Assembly Center SEW-EURODRIVE, Inc. Troy, OH Tel. (937) Fax (937) [email protected] Northeast Region Assembly Center SEW-EURODRIVE, Inc. Bridgeport, NJ Tel. (856) FAX (856) [email protected] Southeast Region Assembly Center SEW-EURODRIVE, Inc. Lyman, SC Tel. (864) Fax (864) [email protected] Southwest Region Assembly Center SEW-EURODRIVE, Inc. Dallas, TX Tel. (214) Fax (214) [email protected] Western Region Assembly Center SEW-EURODRIVE, Inc. Hayward, CA Tel. (510) Fax (510) [email protected] Mexico SEW-EURODRIVE Sales and Distribution SA de CV Queretaro, Mexico Tel. (011) Fax (011) [email protected] Canada SEW-EURODRIVE Co. of Canada Ltd. Bramalea, Ontario Tel. (905) Fax (905) [email protected] SEW-EURODRIVE Co. of Canada Ltd. Delta, B.C. Tel. (604) Fax (604) [email protected] SEW-EURODRIVE Co. of Canada Ltd. LaSalle, Quebec Tel. (514) Fax (514) [email protected] (U.S.) (Canada)

Drive Technology \ Drive Automation \ System Integration \ Service. Introducing the New DR Motor

Drive Technology \ Drive Automation \ System Integration \ Service. Introducing the New DR Motor Drive Technology \ Drive Automation \ System Integration \ Service 1 Introducing the New DR Motor 2 Modular motor system The new motor modular system: Proven technology in new housing one single series

More information

BG or BGE Brake Rectifier

BG or BGE Brake Rectifier Brake Voltage Supplied from the otor There are specific instances when the brake voltage can be tapped from the motor's terminal block. The advantage of brake systems wi in this way is when power is applied

More information

Addendum to the Operating Instructions

Addendum to the Operating Instructions Drive Technology \ Drive Automation \ System Integration \ Services Addendum to the Operating Instructions MOVIMOT with AS-Interface and AC Motor DT/DV Unit Replacement MOVIMOT MM..C -> MM..D with MLK3A

More information

AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing. This document was prepared by Advanced Energy.

AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing. This document was prepared by Advanced Energy. AC Kinetics Variable Frequency Drive Comparative Transient Inertial Testing This document was prepared by Advanced Energy. December 12 th, 2014 Introduction In June of this year, AC Kinetics contacted

More information

Unit 33 Three-Phase Motors

Unit 33 Three-Phase Motors Unit 33 Three-Phase Motors Objectives: Discuss the operation of wound rotor motors. Discuss the operation of selsyn motors. Discuss the operation of synchronous motors. Determine the direction of rotation

More information

C Standard AC Motors

C Standard AC Motors C Standard AC Standard AC C-1 Overview, Product Series... C-2 Constant... C-9 C-21 C-113 Reversible C-147 Overview, Product Series Constant Reversible Electromagnetic Brake C-155 Electromagnetic Brake

More information

Service and Maintenance. SEW-EURODRIVE Driving the world

Service and Maintenance. SEW-EURODRIVE Driving the world SEW Brakes Service and Maintenance 2 Objectives Upon completion of this session, you will be able to do the following: - Identify the components of an SEW brakemotor - Explain the operation of the SEW

More information

Gearmotors and Gear Reducers

Gearmotors and Gear Reducers mors and Reducers OPERATING INSTRUCTIONS 01 805 52 US GENERAL These operationg instructions are intended help you install and operate the drive. For trouble free service, proper installation and operation

More information

Understanding the Alternator

Understanding the Alternator http://www.autoshop101.com THIS AUTOMOTIVE SERIES ON ALTERNATORS HAS BEEN DEVELOPED BY KEVIN R. SULLIVAN PROFESSOR OF AUTOMOTIVE TECHNOLOGY AT SKYLINE COLLEGE SAN BRUNO, CALIFORNIA ALL RIGHTS RESERVED

More information

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS. Redi-Flo2, 2 Environmental Submersible Pumps MP1 Submittal Data QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS Technical Data Motor Type: Water-Filled, variable speed submersible Maximum Fluid

More information

49 Series - Relay interface modules 8-10 - 16 A. Features

49 Series - Relay interface modules 8-10 - 16 A. Features Features 1 & 2 Pole relay interface modules 5 µm Gold plate contacts for low level switching capability 49.31-50x0-1 Pole 10 A (screw terminal) 49.52-50x0-2 Pole 8 A (screw terminal) 49.72-50x0-2 Pole

More information

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X15 mm M O D E L : KD0506PHS2 APPROVED NO : APPROVED BY : (AUTHORIZED) SPEC.NO D600023 ISSUE DATE 08.06.1998 DAWN.

More information

SPEED CONTROL SYSTEM

SPEED CONTROL SYSTEM SPEED CONTROL SYSTEM INDEX SPEED CONTROL MOTOR FEATURES 144 6W ( 70mm) 153 10W ( 70mm) 155 15W ( 80mm) 157 25W ( 80mm) 159 40W ( 90mm) 161 SPEED CONTROL W ( 90mm) 163 90W ( 90mm) 165 120W ( 90mm) 168 180W

More information

TERMINAL MARKINGS AND INTERNAL WIRING DIAGRAMS SINGLE PHASE AND POLYPHASE MOTORS MEETING NEMA STANDARDS

TERMINAL MARKINGS AND INTERNAL WIRING DIAGRAMS SINGLE PHASE AND POLYPHASE MOTORS MEETING NEMA STANDARDS INTRODUCTION The following represents the most up-to-date information on motor terminal marking for proper connection to power source for all alternating current motors manufactured in accordance with

More information

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 55 Series - General purpose relays 7-10 A Features 55.12 55.13 55.14 Printed circuit mount, general purpose 2, 3 & 4 Pole relays 55.12-2 Pole 10 A 55.13-3 Pole 10 A 55.14-4 Pole 7 A AC coils & DC coils

More information

Digi-Motor Installation Guide

Digi-Motor Installation Guide Digi-Motor Installation Guide Installation Video...located at marsdelivers.com Digi-Motor Installation Guide Digi-Motor For technical assistance with your Azure Digi-Motor, call the MARS technical support

More information

TorqPlus TM Electric Valve Actuators and Controls

TorqPlus TM Electric Valve Actuators and Controls TorqPlus TM Electric Valve Actuators and Controls Torque 150 IN/LB 600 IN/LB The Engineered Solution Bettis TorqPlus quality line of electric actuators are designed for quarter turn applications ball,

More information

SUNON SPECIFICATION FOR APPROVAL

SUNON SPECIFICATION FOR APPROVAL SPECIFICATION FOR APPROVAL CUSTOMER : DESCRIPTION : DC BRUSHLESS FAN DIMENSIONS : 60X60X25 mm M O D E L : KDE2406PTB2 APPROVED NO : APPROVED BY : (AUTHORZIED) SPEC.NO D600732 ISSUE DATE 10.01.1998 DAWN.

More information

48 SERIES Relay interface modules 10 A

48 SERIES Relay interface modules 10 A 48 Relay interface modules 10 A 1 CO relay interface modules, mm wide Ideal interface for PLC and electronic systems Type 48.P3 1 CO 10 A s Type 48.31 1 CO 10 A s AC coils or DC sensitive coils Supply

More information

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES After studying this unit, the reader should be able to Describe the different types of open single-phase motors used to drive

More information

8 coil stator 11 coil stator

8 coil stator 11 coil stator Below is a schematic of a typical scooter electrical set up as far as the stator, CDI, rectifier/regulator go along with the other items running on the electrical system; This is the 6 coil stator common

More information

Three-Phase Electric Power Distribution for Computer Data Centers

Three-Phase Electric Power Distribution for Computer Data Centers Three-hase Electric ower Distribution for Computer Data Centers WHITE AER E901 Geist January 008 Summary This paper will describe the characteristics of three-phase power and outline the advantages of

More information

Specifying a Variable Frequency Drive s

Specifying a Variable Frequency Drive s Specifying a Variable Frequency Drive s Put on by Bruce Reeves and Jeremy Gonzales Dykman Electrical Covering the Western US For all of your VFD and Soft Start and Motor Needs How To Specify a Variable

More information

Features and Benefits. Product Overview. Installation Overview. Sales Strategy Overview FPO

Features and Benefits. Product Overview. Installation Overview. Sales Strategy Overview FPO RESCUE EcoTech Direct Drive Blower Motor The High Efficiency ECM/BPM Drop-in Replacement Blower Motor Agenda Features and Benefits Product Overview Installation Overview Sales Strategy Overview FPO High

More information

4 LEAD DEDICATED SINGLE PHASE LIMA MAC GENERATOR MODELS 250MSL1185 AND 250MSL1152

4 LEAD DEDICATED SINGLE PHASE LIMA MAC GENERATOR MODELS 250MSL1185 AND 250MSL1152 4 LEAD DEDICATED SINGLE PHASE LIMA MAC GENERATOR MODELS 250MSL1185 AND 250MSL1152 SERVICE PROCEDURE ELECTRICAL COMPONENT TESTING HI POTENTIAL TETS None of the windings, either rotating or stationary should

More information

WIND TURBINE TECHNOLOGY

WIND TURBINE TECHNOLOGY Module 2.2-2 WIND TURBINE TECHNOLOGY Electrical System Gerhard J. Gerdes Workshop on Renewable Energies November 14-25, 2005 Nadi, Republic of the Fiji Islands Contents Module 2.2 Types of generator systems

More information

KTM AC to DC Stator Conversion Instructions (Floating the ground)

KTM AC to DC Stator Conversion Instructions (Floating the ground) KTM AC to DC Stator Conversion Instructions (Floating the ground) Overview: The following procedure is intended to convert AC (Alternating Current) electrical systems to DC (Direct Current). A qualified

More information

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters www.mbesi.com

Rotating Machinery Diagnostics & Instrumentation Solutions for Maintenance That Matters www.mbesi.com 13 Aberdeen Way Elgin, SC 29045 Cell (803) 427-0791 VFD Fundamentals & Troubleshooting 19-Feb-2010 By: Timothy S. Irwin, P.E. Sr. Engineer [email protected] Rotating Machinery Diagnostics & Instrumentation

More information

09 793 67 US. Operating Instructions Motors and Brakemotors Type BM (G) Brakes

09 793 67 US. Operating Instructions Motors and Brakemotors Type BM (G) Brakes 09 793 67 US sheet 1 (7) General Every SEW-Eurodrive motor is thoroughly tested, checked, and properly packed prior to shipment. However, please check immediately upon arrival for shortage of parts or

More information

Rotary Disconnect Switch Specifications

Rotary Disconnect Switch Specifications Technical Data Rotary Disconnect Switch Specifications Bulletin Number 194R Topic Page Product Line Overview 2 General Specifications Fuse Description 12 Approximate Dimensions 14 Additional Resources

More information

ELECTRIC MOTOR TEFC OPERATION & MAINTENANCE. meps Approved

ELECTRIC MOTOR TEFC OPERATION & MAINTENANCE. meps Approved SOUTH AUSTRALIA HEAD OFFICE (Accounts / Payments) 34-36 Kinkaid Avenue NORTH PLYMPTON SA 5037 Ph: (08) 8295 5566 Fax: (08) 8295 5533 VICTORIA 23 James Street CLAYTON SOUTH VIC 3169 Ph: (03) 9544 2324 Fax:

More information

The Ultimate Truck Stock Motor

The Ultimate Truck Stock Motor The Ultimate Truck Stock Motor What is a Rescue Motor? Universal Replacement Motor for Condenser Fan and Direct Drive Blower Applications Multi-Horsepower PSC Motors Flexible Mounting Options Permanent

More information

Model 201 Wiegand Touchpad Reader Installation Guide

Model 201 Wiegand Touchpad Reader Installation Guide Model 201 Wiegand Touchpad Reader Installation Guide P/N 460353001C 15AUG11 2011 UTC Fire & Security. All rights reserved. This document may not be copied in whole or in part or otherwise reproduced without

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SF-2C-115A-35 S-1AY-12D-35 SD-2C-12D-35 Features High Flow/ High Pressure: Up to 40 gpm / 5000 psi working pressure*.

More information

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves INDUSTRIAL FLUID POWER COMPONENTS AND SYSTEMS SERIES 35 Solenoid Operated Directional Valves SD-2B-115A-35 SDS-2H-12D-35 S-2B-115A-35 Features High Flow/ High Pressure: Up to 25 gpm / 5000 psi working

More information

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A

38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Series - Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 SERIES Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit EMR Electromechanical

More information

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR

DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR 1 DHANALAKSHMI COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING Constructional details Types of rotors EE2302 - ELECTRICAL MACHINES II UNIT-I SYNCHRONOUS GENERATOR PART A 1.

More information

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors

Motor Accessories. C-Face Kits for Field Conversion NEMA AC Motors C-Face Kits for Field Conversion NEMA AC s Features: Complete kits with all hardware necessary for converting Baldor 56 though 449T frame ridgid base motors to C-Face mounting with base. For Baldor conversion,

More information

UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL

UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL UL guidelines, chapter 6.2 / 6.3 Motor Branch Circuits acc. to UL Definition of Terms / Explanations Overview of Basic Devices Construction Types acc. to UL 508 Self-Protected Combination Motor Controller

More information

AC Induction Motor Slip What It Is And How To Minimize It

AC Induction Motor Slip What It Is And How To Minimize It AC Induction Motor Slip What It Is And How To Minimize It Mauri Peltola, ABB Oy, Helsinki, Finland The alternating current (AC) induction motor is often referred to as the workhorse of the industry because

More information

The Energy Independence and Security Act of 2007. The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010

The Energy Independence and Security Act of 2007. The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010 The Energy Independence and Security Act of 2007 The law s requirements for 1 to 500 horsepower AC motors Effective December 19, 2010 January 23, 2009 To Our Customers, Baldor Electric Company 5711 R.S.

More information

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit

PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit PowerFlex 700S and 700H Frame 12 DC Bus Connector Kit Installation Instructions This document provides instructions for the installation of a DC bus connector kit for PowerFlex 700S and 700H frame 12 drives

More information

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE Scaletron Industries, Ltd. Bedminster Industrial Park 53 Apple Tree Lane P.O. Box 365 Plumsteadville, PA 18949 USA Toll Free: 1-800-257-5911 (USA &

More information

Softstarters Type PSR

Softstarters Type PSR Catalog Softstarters Softstarters ABB Softstarters General To the left: A combination with PSR and a manual Motor Starter MS116 Above: PSR16, PSR30 and PSR 45 1 ABB Automation Products serve customers

More information

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products

ECM Motors Manufactured By Regal Beloit. Products and Applications- What s an ECM? GEXPRO Regal Beloit s distribution arm for all ECM motor products ECM Motors Manufactured By Regal Beloit Products and Applications- What s an ECM? ECM 2.3 series ECM 142 Arktic ECM 58mm Arktic ECM 59 Arktic SSC2 Arktic 51 GEXPRO Regal Beloit s distribution arm for all

More information

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC

D7 Series Standard and Full Featured. Standard DPDT 24V AC 120V AC 240V AC 12V DC 24V DC 120V AC 110V DC 240V AC 6V AC 6V DC 12V AC 12V DC 24V AC April 00 D Series Standard and Full Featured - Catalogue Number Structure Table -. D Series Catalogue Numbering System Family Type DPR = Standard Relay DPF = Full Featured Relay Contact Configuration =

More information

Principles of Adjustable Frequency Drives

Principles of Adjustable Frequency Drives What is an Adjustable Frequency Drive? An adjustable frequency drive is a system for controlling the speed of an AC motor by controlling the frequency of the power supplied to the motor. A basic adjustable

More information

Architectural Specifications MODEL HDXL 9. 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8

Architectural Specifications MODEL HDXL 9. 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 MODEL HDXL 9 200 Fairview Road, Unit #2, Barrie, Ontario L4N 8Z8 Tel: 866-792-9968 or 705-792-9968 Fax: 705-735-9564 www.tnrdoors.com email: [email protected] Model HDXL 9 Tech Specs September 4, 2012

More information

Type SA-1 Generator Differential Relay

Type SA-1 Generator Differential Relay ABB Automation Inc. Substation Automation and Protection Division Coral Springs, FL 33065 Instruction Leaflet 41-348.11C Effective: November 1999 Supersedes I.L. 41-348.11B, Dated August 1986 ( ) Denotes

More information

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles

AC Motor Speed. n s = synchronous speed (in RPM), f = frequency (in Hz), and p = the number of poles AC Induction Motors Simplest and most rugged electric motor Consists of wound stator and rotor assembly AC in the primary member (stator) induces current in the secondary member (rotor) Combined electromagnetic

More information

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION Chromalox Installation, Operation RENEWAL PARTS IDENTIFICATION Portable Industrial Unit Blower Air Type DRA and DIVISION SALES REFERENCE DATE SECTION (Supersedes P-) PF-) NOVEMBER, 00 DRA PF- -0-00 Specifications

More information

Xenon HID Lighting System

Xenon HID Lighting System Automotive Safety Systems User Installation Manual Preface Specifications Thank you for purchasing NOVABLUE Xenon H.I.D. (High Intensity Discharge) vehicle lighting systems. Before installing this product,

More information

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0.

48.12. 2 pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2,000 500 0.37 8/0.65/0. 48 Series - Relay interface modules 8 A Features 48.12 2 Pole Safety relay interface modules, 15.8 mm wide 48.12-2 Pole 8 A (screw terminal) DC sensitive coils Relay with forcibly guided contacts according

More information

IV. Three-Phase Induction Machines. Induction Machines

IV. Three-Phase Induction Machines. Induction Machines IV. Three-Phase Induction Machines Induction Machines 1 2 3 4 5 6 7 8 9 10 11 12 13 Example 1: A 480V, 60 Hz, 6-pole, three-phase, delta-connected induction motor has the following parameters: R 1 =0.461

More information

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS

INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS INSTALLATION AND MAINTENANCE INSTRUCTIONS FOR THREE PHASE INDUCTION MOTORS Frames 143T - 449TZ 5100 North IH 35 Round Rock, Texas 78681 Phone: 800-451-8798 512-255-4141 Fax: 512-244-5512 RECEIVING 1. Check

More information

A1000 Cheat Sheet (Open Loop Vector)

A1000 Cheat Sheet (Open Loop Vector) A1000 Cheat Sheet (Open Loop Vector) The following procedure is a supplement to supplied with this equipment and will guide the user in properly wiring the A1000 and. It will also show the user how to

More information

Drive Engineering Practical Implementation. SEW Disk Brakes. Edition 11/2008 16668413 / EN

Drive Engineering Practical Implementation. SEW Disk Brakes. Edition 11/2008 16668413 / EN Drive Technology \ Drive Automation \ System Integration \ Services SEW Disk Brakes Edition /008 6668 / EN Drive Engineering Practical Implementation SEW-EURODRIVE Driving the world Contents Important

More information

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions: The Charging System Charging System The charging system has two essential functions: Generate electrical power to run the vehicle s electrical systems Generate current to recharge the vehicle s battery

More information

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 INSTALLATION GUIDE Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930 Card Reader and Controller Model 3.5 with KIM Swipe Reader Table of Contents 1. Features..................................

More information

Enterphone Solo. User/Installation Manual Part No. 421-2001

Enterphone Solo. User/Installation Manual Part No. 421-2001 Enterphone Solo User/Installation Manual Viscount Communication and Control Systems Inc. 4585 Tillicum Street, Burnaby, B.C., Canada V5J 5K9 Phone: (604) 327-9446 Toll Free: 1-800-476-3774 Fax: (604) 327-3859

More information

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

38 SERIES. Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6. 38 Relay interface modules 0.1-2 - 3-5 - 6-8 - 16 A 38 Common features Instant ejection of relay by plastic retaining clip Integral coil indication and protection circuit 6.2 mm wide EMR - DC, AC or AC/DC

More information

Motor Protection Voltage Unbalance and Single-Phasing

Motor Protection Voltage Unbalance and Single-Phasing Motor Protection Voltage Unbalance and Single-Phasing Cooper Bussmann contributes the following information, which is an excerpt from their 190-page handbook SPD Selecting Protective Devices Based on the

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 4 AND 8 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information

Product Information. HMC 6 Hybrid Motor Cable

Product Information. HMC 6 Hybrid Motor Cable Product Information HMC 6 Hybrid Motor Cable November 2014 HMC 6 Single-cable solution for servo drives Motors normally need two separate cables: One cable for the motor encoder One cable for the motor

More information

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW ADS8 IP54 Direct-On-Line Starter Technical Focus Replaces ADS7 Rated up to 9kW New ADS8 Motor Starter The new ADS8 range of motor starters replaces the successful ADS7 range which was introduced 20 years

More information

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit

PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit Installation Instructions PowerFlex 700H and 700S AC Drives Frame 11 Main Fan Capacitor Replacement Kit ATTENTION: The sheet metal cover and mounting screws on the ASIC Board located on the power structure

More information

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig Through hollow shaft Ø 5 bis 4 mm Outside diameter only 76 mm Easy installation by means of clamping ring front or rear Operating temperature up to 00 C Applications: motors, printing machines, lifts NUMBER

More information

Motor Fundamentals. DC Motor

Motor Fundamentals. DC Motor Motor Fundamentals Before we can examine the function of a drive, we must understand the basic operation of the motor. It is used to convert the electrical energy, supplied by the controller, to mechanical

More information

Cable Plug acc. to DIN EN 175301-803, Form A

Cable Plug acc. to DIN EN 175301-803, Form A Cable Plug acc. to DIN EN 175301-803, Form A Complete program Contact form 18 mm Also available with LED indicator Optional 4-pin version for pressure switch or impulse valves respectively Versions with

More information

Buck - Boost Transformers

Buck - Boost Transformers Buck - Boost Transformers Contents Buck - Boost Transformers - Terms & Definitions... 48 Buck - Boost Transformers - Sizing... 50 Quick Reference Chart - 08, 0, 40 Volts Single & Three Phase... 5 Single

More information

NC-12 Modbus Application

NC-12 Modbus Application NC-12 Modbus Application NC-12 1 Table of Contents 1 Table of Contents... 2 2 Glossary... 3 SCADA...3 3 NC-12 Modbus in general... 3 4 Entire system... 4 4.1 PFC to PC connection alternatives...4 4.1.1

More information

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.: 2964050 Extract from the online catalog DEK-REL- 24/1/SEN Order No.: 2964050 Relay terminal block for sensor, with soldered-in miniature relays, contact (AgNi+Au): small to medium loads, 1 N/O contact, input voltage

More information

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet

ABB ! CAUTION. Type COQ Negative Sequence Generator Relay. (50/60 Hertz) 41-161J. Instruction Leaflet ABB Instruction Leaflet 41-161J Effective: May 1997 Supersedes I.L. 41-161H Dated July 1984 ( ) Denotes Change Since Previous Issue Type COQ Negative Sequence Generator Relay (50/60 Hertz)! CAUTION Before

More information

Application Information Fully Integrated Hall Effect Motor Driver for Brushless DC Vibration Motor Applications

Application Information Fully Integrated Hall Effect Motor Driver for Brushless DC Vibration Motor Applications Application Information Fully Integrated Hall Effect Motor Driver for Brushless DC Vibration Motor Applications By Shaun Milano Vibration motors are used in a variety of applications including mobile phone

More information

Equipment: Power Supply, DAI, Universal motor (8254), Electrodynamometer (8960), timing belt.

Equipment: Power Supply, DAI, Universal motor (8254), Electrodynamometer (8960), timing belt. Lab 12: The universal motor. Objective: to examine the construction of the universal motor; to determine its no-load and full-load characteristics while operating on AC; to determine its no-load and full-load

More information

Model RC Armature-Slot- Insulation Folder

Model RC Armature-Slot- Insulation Folder Model RC Armature-Slot- Insulation Folder 21 Model RC will handle insulation material up to 8 wide between its guides. Creasing rollers are adjustable sideways to make troughs up to 6 wide. A fixed ruler-guide

More information

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA

Speed Control Methods of Various Types of Speed Control Motors. Kazuya SHIRAHATA Speed Control Methods of Various Types of Speed Control Motors Kazuya SHIRAHATA Oriental Motor Co., Ltd. offers a wide variety of speed control motors. Our speed control motor packages include the motor,

More information

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal

93.68/93.69. Time scale: from 0.1s to 6h Multi-function For use with 34.51 (EMR) and 34.81 (SSR) relays. Screw terminal and push-in terminal Series - Timed socket for 34 series Features.68/.69 Slim timed sockets for 34 series, 6.2 mm wide Timer adjustment via top mounted rotary knob accessible after assembly Control signal terminal DIP-switch

More information

Italvibras USA. Operator s Manual

Italvibras USA. Operator s Manual Italvibras USA Industrial Electric Vibrators Model Operator s Manual Table of Contents Section Title Page Tables and Figures Index.................................Below Introduction.................................................1

More information

Windshield Wiper Motors

Windshield Wiper Motors Windshield Wiper Motors Originally posted by Dan Masters, [email protected] Also see http://www.advanceautowire.com/ WIPER OPERATION: There are three major components to a wiper motor: Motor Rotary to linear

More information

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL Rev. D PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL 10 BORIGHT AVENUE, KENILWORTH NEW JERSEY 07033 TELEPHONE: 800-524-0273 FAX: 908-686-9317 TABLE OF CONTENTS Page

More information

DIRECTIONAL CONTROL VALVES

DIRECTIONAL CONTROL VALVES Series 35 High Flow High Pressure Directional Valves D05SD DIN Type D05S Electrical Box Type D03SD DIN Type D03S Electrical Box Type D03SL Lead Wire Type (D05SL Lead Wire Type Also available) FEATURES

More information

Catalog DRS Gearmotors

Catalog DRS Gearmotors Drive Technology \ Drive Automation \ System Integration \ Services Catalog DRS Gearmotors Edition 06/2009 68400 / EN SEW-EURODRIVE Driving the world Content Preface... 6 2 Product Description... 0 2 3

More information

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original A motor starter is a combination of devices to allow an induction motor to start, run and stop according

More information

Overload Relay Heater Tables

Overload Relay Heater Tables Overload Relay Tables of Elements for Overload Relays Use only when motor full load current is not known. Motor amps will vary depending on the type and manufacturer of the motor. These average values,

More information

Electric Motor Brake Horsepower Calculations

Electric Motor Brake Horsepower Calculations Electric Motor Brake Horsepower Calculations By Norm Christopherson These motor calculations are contained here as they apply to the changing conditions of the blower motor when pulley adjustments are

More information

Number 1 in efficiency

Number 1 in efficiency PowerXL DE1 Variable Speed Starter www.eaton.eu/de1 Number 1 in efficiency The easiest way of variable motor speed NEW Variation DE11 The new device category! The PowerXL DE1 Variable Speed Starter Why

More information

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE.

EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. EVER EFFICIENT. EVER RELIABLE. EVER PROFITABLE. A Regal Brand EVERGREEN SOLUTIONS Powered by ECM Technology Upgrade/Replace PSC motors with Evergreen IM Residential/Light Commercial HVAC Systems Reduce

More information

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research):

AC generator theory. Resources and methods for learning about these subjects (list a few here, in preparation for your research): AC generator theory This worksheet and all related files are licensed under the Creative Commons Attribution License, version 1.0. To view a copy of this license, visit http://creativecommons.org/licenses/by/1.0/,

More information

Installation and Operation Guide PD4600 Series Converter Replacement

Installation and Operation Guide PD4600 Series Converter Replacement Installation and Operation Guide PD4600 Series Converter Replacement Extended warranties are available for purchase at www.progressivedyn.com Member Thank you for selecting Progressive Dynamics as your

More information

ENGINE ALTERNATOR REPOWER GUIDE

ENGINE ALTERNATOR REPOWER GUIDE ENGINE ALTERNATOR REPOWER GUIDE ThePowerPortal.com Your One Your Stop One Information Stop Source Information Source Briggs & Stratton has developed a powerful and flexible private web-based portal for

More information

Data Sheet. AC Industrial Electric Motors

Data Sheet. AC Industrial Electric Motors Data Pack B Issued ovember 2005 1502325812 Data Sheet AC Industrial Electric Motors Standards organisations The RS-ABB range of ac induction motors is produced to common European standards, these being

More information

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color) Innovative indicators in a slim & stylish design. uces installation space. LH Series Surface Mount Indicators Key features of the LH series include: Direct mounting on surfaces such as panels, aluminum

More information

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060

Service Facts. WARNING: HAZARDOUS VOLTAGE - DISCONNECT POWER and DISCHARGE 4TTM3-SF-1. Split System Cooling 4TTM3018-4TTM3060 4TTM3-SF-1 Service Facts Split System Cooling 4TTM3018-4TTM3060! CAUTION UNIT CONTAINS R-410A REFRIGERANT! R-410A OPERATING PRESSURE EXCEEDS THE LIMIT OF R-22. PROPER SERVICE EQUIPMENT IS REQUIRED. FAILURE

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Electric Vacuum Pump Kit 28146 Thank you for choosing STAINLESS STEEL BRAKES CORPORATION for your braking needs. Pleases take the time to read and carefully follow these instructions

More information

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C DESCRIPTION FEATURES PRODUCT DATA Very low operating trip points LED status indication Integral DIN rail mounting

More information

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE.

BOWL ASSEMBLY SELECTION Select impeller in exactly the same manner as for lineshaft type pump. Note comments under WELL SIZE. SUBMERSIBLE PUMP selection A submersible pump consists of the following basic elements: < Bowl Assembly < Motor < Cable < Drop Pipe < Surface Plate (with)(without) discharge elbow DATA REQUIRED FOR SELECTION

More information