MGE TM Galaxy TM 7000

Similar documents
MGE Galaxy /200/250/300/400/500 kva Power efficiency for business continuity

Galaxy VM. Three-phase power protection. schneider-electric.com

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

RIELLO ELETTRONICA. Master HP

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

Phase Modular Finally the benefits of Modular ups are for all

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

SG Series UPS kva three phase 400 Vac

4.0 UPS dedicated to ICT for unmatched energy savings

Chloride 80-NET from 60 to 500 kw. Secure Power for Mission Critical Applications

GE Digital Energy. SG-CE Series UPS kva three phase 400 Vac Uninterruptible Power Supply (UPS) imagination at work

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

Technical Specifications

LAP ENERGIA PARA DATACENTERS

415V DISTRIBUTION FOR GREEN DATA CENTERS

Liebert APM from kw. The Compact Row-Based UPS With FlexPower Technology TM

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

PowerGem Pro Uninterruptible Power Supply

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

Thyristor-controlled power supplies and battery chargers

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

415V DISTRIBUTION FOR GREEN DATA CENTERS

CEMEP UPS. The high environmental performance solution for power supply to high-availability data centers

GE Consumer & Industrial Power Protection. Digital Energy LP Series UPS. Uninterruptible Power Supply 3-30 kva. GE imagination at work

Uninterruptible Power Supply

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

UPS system for emergency lighting and smoke extraction

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

Schneider Electric GALAXY VM Data Center Grade Three Phase Uninterruptible Power Supply Guide Specifications kva UPS

User Manual 1K/2K/3K Online UPS

Power Meter Series 700

TX OPEN RS232/485 module

Eaton 93PM UPS Where aesthetics meet intelligence.

Technical Specification Kohler PW 5000/TP

Yam Hong 施 耐 德 電 機 亞 太 日 本 區 (APJ) 三 相 關 鍵 電 源 市 場 開 發 經 理. Schneider Electric - Division - Name Date

Low Voltage Products

ABB central inverters PVS to 1000 kw

User s Manual Before using the inverter, you need to read and save the safety instructions.

Liebert 80-eXL from 100 to 1200 kw. Enhanced Design and Improved Efficiency

Trinergy from 200 to 1600 kw. High Power Modular Scalable UPS With Three Dynamic Functioning Modes

Protect. UPS Solutions for large Data centers

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

PowerValue TM. Compact protection for power supply For Continous Power Protection Availability

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

The Quest for Energy Efficiency. A White Paper from the experts in Business-Critical Continuity

Smart-UPS 3 Phase And MGE Galaxy 3500

TLE Series. Product Description kva / 400Vac / S1 KEY BENEFIT APPLICATIONS FEATURES

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

Permissible ambient temperature Operation Storage, transport

The Different Types of UPS Systems

How To Make A Fronius Cl Power Inverter

Digital input modules

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Online UPS. PowerWalker VFI 1000R/1U

Technical Data. back-up time in minutes 100% load % load

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

Technical data UNIBLOCK UBSF

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

ECOCIAT. Domestic hot water heat recovery unit

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

Data Sheet FUJITSU Storage ETERNUS LT260 Tape System

Photovoltaic Solar Energy Unit EESFB

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

Powerline 1200 User Manual

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

EMC VMAX3 FAMILY VMAX 100K, 200K, 400K

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

Liebert NXC from 10 to 200 kva

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

ELEKTROTEHNI KO PODJETJE Leskoπkova cesta 12, 1000 Ljubljana, SLOVENIA

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Data Centre Services. JT First Tower Lane Data Centre Facility Product Description

TLE Series UPS kw for best-in-class multi-mode operating efficiency

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

APC by Schneider Electric MGE GALAXY 3500 Uninterruptible Power Supply Guide Specifications 10 kva to 40 kva in / V Solution

INVERTER SYSTEM PRODUCT BROCHURE

UPS Topologies & Architectures. Don Lemmon Tubbesing Solutions (214) don@tubbesing.com

The UPS for the highest security in industry and data centres

Smart-UPS 120 V. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Cisco Nexus 7000 Series Power Supply Modules

Smart-UPS On-Line 230 V

Transcription:

MGE TM Galaxy TM 7000 Power efficiency for business continuity 160/200/250/300/400/500 kva > Performance 3 Phase Power Protection with High Adaptability to Meet the Unique Requirements of Medium to Large Datacenters, Buildings and Mission Critical Environment > Flexible and Very Adaptable > Advance Electrical Features > Parallel Capable > High Efficiency > Output Synchronization to External Source > High Availability Architectures Component

An innovative solution to make life simple Easy to choose Compatible with all load types > Output power factor = 0.9, in line with the latest generation of IT applications > No derating for leading power factors > High short-circuit and overload capacities for motor loads Compatible with all battery types > Lead-acid batteries (vented, sealed) > Ni-Cad Compatible with all backup time > The high power charger rapidly charges batteries for backup times up to four hours Harmonic free rectifier > No additional harmonic filtering is required MGE Galaxy 7000 can operate at different frequencies and voltages, i.e. 50 / 60 Hz and 380 to 440 V. It also displays all information in 19 languages. Easy integration into electrical networks Schneider Electric, a leader in harmonic management, has built a true IGBT rectifier into the MGE TM Galaxy TM 7000. Upstream THDI is less than 5% and the input power factor is greater than 0.99. > Less reactive power > Fewer harmonics injected upstream > Savings in network component ratings such as circuit breakers, cables, etc. > Fully compatible with generator sets. In addition to its high input power factor, Galaxy 7000 features a soft start capability. A 400 kva UPS only requires a 440 kva generator set. Easy to install > Small footprint > No need for rear or side access. All connections are made through the front > Integration of all switches requiring connection > Ready for all system earthing arrangements Phase sequence detection prevents start-up if the phase order is incorrect. Easy to operate Locally > The MGE Galaxy 7000 intuitive user interface provides clear, relevant information for easy operation. With its 5000 timestamped events, statistical analysis and energy flow pictograms, system management could not be simpler. Remotely > The MGE Galaxy 7000 provides valuable information to supervision systems on: The UPS and its environment, Controlled shutdown of operating systems. > A number of different communication protocols are available for remote operation: Ethernet 10/100 Mbps with HTTPS encryption for browser and NMS supervision, J-Bus/Mod-Bus for BMS systems, Modem for teleservice, Simple programmable current loop contacts. Any screen may be selected as the standard display. For example, if output measurements are a critical parameter, select the output measurement screen as the default display. Easy to upgrade Power and redundancy upgrades > Power requirements can change over time. MGE Galaxy 7000 output can be multiplied by a factor of eight. Redundancy can also be added or upgraded as needed, e.g. 2N, N+1 or N+2.

Efficient product: power availability and energy savings Up to 94.5% efficiency means significant savings The innovative technology built into the MGE Galaxy 7000, including digital electronics for better and faster regulation, an IGBT rectifier and transformer less design, results in high efficiency. Benefits > Energy savings to cut costs > Reduced air conditioning and ventilation in the UPS room Sized for harsh environments Robust electrical performance The sizing and quality of power components result in unsurpassed output performance for MGE Galaxy 7000: High fault-clearing capabilities, High load crest factor > 3:1, Excellent voltage stability, even for stepped load switching or unbalanced loads, No derating, even for loads with a leading power factor, No problems with industrial loads. Benefits > High fault-clearing capacity for better discrimination in the electrical network > Compatibility with all types of loads, including computer loads and loads with high crest factors Clean, stable output waveform The digitally controlled IGBTs and high technology output filter provide a very clean, stable output voltage waveform with less than 2% total harmonic distortion (THDU), even for: Stepped load switching, Unbalanced loads. Benefits > Optimum supply for loads > Increased life expectancy for the protected equipment Flexible architecture High availability results not only from UPS reliability, but also from innovative and resilient architectures providing: Source redundancy, Power-distribution redundancy. Parallel connection for increased power with a centralized bypass unit and up to 8 UPS units Live standby redundancy Distributed parallel connection for increased power and redundancy. Distribution redundancy with the Static Transfer Switch (Upsilon STS) Digital electronics offer additional features. The available output power is automatically adapted to the temperature, e.g. a 500 kva UPS delivers 538 kva at 20 C ambient temperature.

The most comprehensive range of services Commissioning Schneider Electric Critical Power and Cooling Services can commission all new equipment and provides the necessary support services to meet your specific requirements. Maintenance contracts UPS s must be managed and monitored to keep them in optimum working order. Schneider Electric Critical Power and Cooling Services offers three levels of maintenance contract: ULTRA : For end to end service, all-inclusive for guaranteed peace of mind. PREMIER : For effective, basic preventive Maintenance. SELECT : Pick and mix. Upgradeable Installations must remain up-to-date, that is why Schneider Electric Critical Power and Cooling Services provides upgradeable solutions : Technical upgrades, Upgrading of battery functions, Site audits, studies and analysis of the UPS environment, Harmonic audits, Swap-Pac upgrading of the UPS function to anticipate and adapt to changes in your needs, and to provide end of life cycle environmental management. The MGE TM Galaxy TM 7000 Life Cycle Monitoring system has built-in sensors for components such as batteries and capacitors that require preventive maintenance. The diagnostics software warns of impending deadlines. Timely preventive replacement keeps critical loads up and running. Teleservice monitoring services Teleservice continuously monitors the installation 24/365 and sends alerts to you and the service centre. Powerful diagnostic systems and the largest network of UPS experts worldwide help maintain system availability.

Reducing environmental impact for sustainable development Beyond international environmental regulations The data centre and critical power industry must commit to environmental issues. Schneider Electric systematically attempts to exceed current and future requirements imposed by standards. That includes: ISO 14001 certification of sites and R&D, Eco-design based on ISO 14040 &14060 standards & eco-production, a true commitment to sustainable development. MGE TM Galaxy TM 7000 takes the environmental issue into account at each stage of the product s life. Design Reducing the number of parts improves reliability and reduces impact on the environment. The MGE TM Galaxy TM 7000 design team used advanced digital electronics to achieve savings: fewer electronic boards, software updates via downloading instead of changing boards. Raw materials Thanks to its compact size and low weight, the MGE TM Galaxy TM 7000 requires fewer raw materials and the types used are more environmentally friendly. > Power efficient components: specific choke coils, smaller output filters. > New design for a transformerless UPS: more silicon, less copper, more powerful IGBTs. The weight of the MGE TM Galaxy TM 7000 has been halved compared to the previous generation. Manufacturing according to environmental standards MGE TM Galaxy TM 7000 is produced in factories that comply with the ISO 14001 standard to reduce: energy consumption, packaging waste for supplier parts, amounts of materials used in the process. End of Life recycling > End of product life: Safety instructions, list of parts containing regulated substances and their position in the UPS. Energy efficiency thanks to quality power solutions > Reduced consumption thanks to the green IGBT rectifier (low harmonics), which in turn reduces sizing of the electrical distribution system (breakers, cables, generator). > High efficiency UPS solutions to reduce heat losses: up to 94,5% efficiency in on-line mode,

Technical characteristics Rated power (kva) 160 200 250 300 400 500 Normal AC input Input voltage range 250 V(1) to 470 V, three phase Normal and bypass AC inputs Separate Frequency 45 Hz to 66 Hz Input current distortion (THDI) < 5 % Input power factor > 0.99 Phase sequence detection Yes Bypass AC input Input voltage range (380 V, 400 V, 415 V, 440 V) +/- 10% Frequency 50 Hz / 60 HZ +/- 10% Output Power factor 0.9 Phase-to-phase voltage setting 380/400/415/440 V, three-phase + neutral Voltage regulation -1% Frequency 50 or 60 Hz +/- 0.1% Permissible overloads 150% for 30 s, 125% for 10 minutes Voltage distortion (THDU) < 2% Ph/Ph and Ph/N for non-linear loads Battery Number of battery chains managed Up to 2 circuit breakers Type Sealed lead-acid, vented, Ni-Cd Overall efficiency Double conversion Up to 94.5% Environmental conditions Operating temperature Up to 40 C (2) Humidity Up to 95% (non-condensing) Operating altitude Up to 1000 m, without derating Color RAL 9023 IP degree of protection IP20 Standard, IP32 Optional Parallel configurations Integrated parallel units Up to 8 units Parallel modules with remote centralized static bypass Up to 8 units switch (3) Standards Construction and safety IEC/EN 62040-1, IEC/EN 60950 Performance and topology IEC 62040-3 Design and manufacture ISO 14001, ISO 9001, IEC 60146 EMC immunity IEC61000-4 EMC emissions IEC 62040-2 C3 Approvals LCIE - CE Mark UPS dimensions (depth 855 mm, height 1900 mm) Rated power (kva) 160 200 250 300 400 500 Width (without battery, in mm) 1412 1812 Weight (in kg)-note 5 840 990 1140 1500 (1). Depending on load level. (2). 8 hours max., 35 C continuous. (3). 160 and 200kVA not included