STAND-ALONE CLC SYSTEMS SUBMITTALS FOR RELEASE



Similar documents
GLPHASE System. System Components GLPHASE - KP- KP- KP- KP- OS- DS SpaceBuild Specification Worksheet. Touch Screens

GLPAC-DIMFLV Crestron Green Light Integrated Lighting System

INSTALLATION INSTRUCTIONS

BACnet Automation Interface Module (Network Version)

GRAFIK 5000TM/6000 /7000TM System Onsite Startup

Crestron C2N-ANLZ Cresnet Analyzer Operations Guide

MechoNet TM Network Interface (MNI) Specification Submittal

SECTION LOW VOLTAGE LIGHTING CONTROLS

Reference Design. conference rooms

T7560A,B,C Digital Wall Module

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

Applied Electronics. Commercial Dimming System UPDATE NOTICE

SECTION INTEGRATED AUTOMATION SOFTWARE FOR CONTROL OF MONITORING NETWORKS

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

LiteKeeper 4 & 8 Programming Guide and User Manual

Application/Connection Examples

Switching Power Module

Advantium 2 Plus Alarm

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

TrueAlarm Fire Alarm Systems

Electronic Control Devices The European Product Catalogue 2007

ilux Lighting Systems

EMBEDDED ACCESS CONTROL Hardware Installation Guide

FIRE ALARM SYSTEM. A. Shop drawings shall be submitted as follows: 1. Manufacturer's published literature. for aspproval.

High Bay Occupancy Sensor Selection Guide

NX-591NE-GSM NetworX GSM 3G HSPA+ Module Installation Sheet

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

LDG DTS-4/4R Desktop Coaxial Switch / Remote

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

LP Dimming Panels. GRAFIK Systems. Power Equipment. LP Dimming Panels

QSE-CI-NWK-E Control Interface

Lighting Management solutions

Phase-Adaptive Power Module

Installation Guide Solar Connect-11

EDI Distributor Control Interface Wiring and Setup Instructions

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Vision Engravers and Routers PRE-Installation Guide Vision Engraving & Routing Systems

Lighting Controls ! WARNING RISK OF ELECTRIC SHOCK. Installation Instructions DESCRIPTION

HomeWorks QS Processor

IP DSLAM IDL Quick Installation Guide

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Disclaimers. Important Notice

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

SECTION ( ) FIRE DETECTION AND ALARM SYSTEM

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

How To Power A Power Control On An Ip40 (Ipl) With A Power Supply (Iplug) With An Ip20 Controller (Iphones) With Power Control (Power Control) With No Antenna) With The Ip20 (Power)

GPD 506/P5 Start-up Procedure and Checklist

DALI Power Module (LQSE-2DAL-D) DALI Bus 1. DALI Bus 2. HomeWorks. Wallstation. Power. Eye QS Control Power Up to 100. Module.

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

How To Use A Lutron Power Supply

SECTION POWER MONITOR FOR ELECTRICAL, STEAM CONDENSATE, AND WATER PART I - GENERAL

LOS 2500 SUPER CEILING SENSOR. Installation Manual

FIRE ALARM AND DETECTION SYSTEMS SECTION 16721

SECTION WEB-BASED POWER MONITORING COMMUNICATIONS SYSTEM

SECTION OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section

* DISCLAIMER: Contents. How to Use This Guide: COMMERCIAL INSTALL GUIDE 2

Y7230A CO 2 Alarm System

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

SECTION INTERIOR LIGHTING FIXTURES, LAMPS, AND BALLASTS

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

NELSON VOLTAGE MONITOR INSTALLATION & PROGRAMMING MANUAL

EQUIPMENT SPECIFICATIONS

LIEBERT VNSA Installation Sheet

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Perle 10/100 Ethernet Media Converters

On/Off Relay Switch and 3-Way Switch Kit

ColorDial Pro Easily configure and control LED light shows

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

HP UPS R1500 Generation 3

Operation and Installation Manual

DIVISION 28 ELECTRONIC SAFETY AND SECURITY SECTION SECURITY AND ACCESS CONTROL SYSTEM

Provides one channel for Ethernet over existing

VX 2400 Dimmer User's Manual

XPanel V2. Remote Control Panel. User Manual. XILICA Audio Design

SLIM LINE FUME HOOD MONITOR

LANTANA LUMINAIRE HI-LUME 1% ECOSYSTEM LED DRIVER L3DA4U1UMN-XXXXX

User manual Rev 1.3 Contents

WxGoos-1 Climate Monitor Installation Instructions Page 1. Connections. Setting an IP Address

Cisco Unified IP Conference Phone 8831 Installation

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Master Time Clock MTC-200 MTC-400 MTC-600. Users Manual

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

SECTION ACCESS CONTROL SYSTEM. CONDITIONS OF THE CONTRACT AND DIVISION 1, as applicable, apply to this Section.

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

ZC-24DO CANopen I/O Module: 24 Digital Outputs

RAY-MAX Integrated Solar Power Strip

Provides one channel for Ethernet over existing

Installation and User Guide

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

How to read this guide

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

Energy Communication Unit (ECU)

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

LocoNet, the Digitrax Difference

Transcription:

L:\Lighting\00 - Templates\AutoCAD Blocks\000 - Submittal CAD Blocks\Cover Page and LOT\Crestron-QR.png L:\Lighting\00 - Templates\AutoCAD Blocks\000 - Submittal CAD Blocks\Cover Page and LOT\Crestron-QR.png STAND-ALONE CLC SYSTEMS SUBMITTALS FOR RELEASE ELECTRICAL DISTRIBUTOR / DEALER RELEASE RELEASE SIGNATURE DATE TYPED / PRINTED NAME COMPANY PLEASE ENSURE THAT YOU HAVE THE LATEST VERSION OF DRAWINGS FOR THIS PROJECT SCAN THE QR CODE ABOVE TO DOWNLOAD THE CURRENT CRESTRON DRAWING SET SIGNING HERE INDICATES RESPONSIBILITY FOR THE FOLLOWING:. THE PIECES PARTS AND SERVICES REQUI TO MEET THIS PROJECTS LIGHTING CONTROL INTENT.. LUMINAIRE LOAD TYPES ARE COMPATIBLE WITH WITH THE CONTROLS SHOWN AND ARE ACCURATELY CAPTU IN THE LOAD SCHEDULE.. COLORS AND FINISHES ARE ACCURATE ON THE ATTACHED PURCHASE ORDER. ITEMS REQUI FOR EQUIPMENT SHIPMENT:. ELECTRICAL DISTRIBUTOR / DEALER RELEASE INTENT BY SIGNING THIS FORM. DISTRIBUTOR RELEASE PO. CRESTRON SALES REPRESENTATIVE PO. CRESTRON SALES REPRESENTATIVE STAND-ALONE SERVICES WORK SHEET THESE FOUR DOCUMENTS SHOULD BE SENT TO CLCORDERS@CRESTRON.COM. UPON RECEIPT THE PROJECT WILL BE CHECKED FOR COMPLETENESS AND PROCESSED FOR RELEASE. WARNING THIS DOCUMENT SET DOES NOT DESCRIBE AN INSTALLABLE SYSTEM UNTIL IT HAS BEEN REVIEWED FOR CODE COMPLIANCE BY THE PROJECT ELECTRICAL ENGINEER. ALTHOUGH EVERY EFFORT HAS BEEN MADE TO PRODUCE A COMPLETE AND CODE-COMPLIANT DESIGN, CRESTRON INC. SPECIFICALLY DISCLAIMS ANY RESPONSIBILITY FOR CODE COMPLIANCE, WHICH IS THE RESPONSIBILITY OF THE PROJECT ELECTRICAL ENGINEER. Crestron General System Notes Not all notes will be pertinent to all projects. The installing contractor should review these notes and determine their applicability to the project. System Wiring & Electrical All installation and termination labor is furnished by the project electrical contractor. All Ethernet wiring must be terminated to the appropriate ANSI/EIA wiring specification. All other control wiring must be terminated per the Crestron wiring specification shown in this document. All line voltage conductors of the same circuit shall be contained in the same conduit, raceway, auxiliary gutter, cable tray, or cable. All low voltage control wire shall be separated appropriately to eliminate any possibility of secondary induced voltage due to line voltage wires in close proximity. Load circuit wiring shall have individual neutrals for any circuit with line-voltage dimming. Line feeds are to be determined by others. Phase-balancing of loads is to be determined by others. If this requires modification of Crestron panels, Crestron must be notified immediately and submittals shall be revised to ensure accurate programming of system. Replacement hardware shall be re-installed by licensed Electrical Contractor only. All Crestron control devices have an associated serial number. The Electrical Contractor must identify each SN for each device, and their location of installation on the plans. This information is required to program the system. System Start-up Three weeks prior to needing commissioning, the electrical contractor must fill out and submit the System Commissioning Forms on the following pages. In order to accomplish the system commissioning, the Crestron field engineer must have full access to the jobsite during normal business hours, 8am-5pm local time. An additional premium rate will apply if work must be performed outside of normal business hours or at night, on weekends, or on nationally-recognized holidays. In order to commission the system, the Crestron field engineer must be able to access all equipment. If this access is only available via ladder or lift, it is the contractor's responsibility to provide such equipment and all related safety gear required for proper access. Control System Power It is recommended that the system processor and all control signal distribution equipment be supplied by a dedicated, backed up, clean power source with surge & spike protection, furnished by others unless specifically noted otherwise in this submittal. Fluorescent Lamps If fluorescent lamps are being dimmed, we recommend that all lamps, including a stock of spares, should be burned in at full intensity for 00 hours prior to dimming. This will improve lamp life and dimming performance. Please also review any manufacturer recommendations. Ethernet Ethernet infrastructure to support and troubleshoot operation of the equipment in this submittal, except where specifically shown as "BY CRESTRON", shall be furnished & configured by others. An Ethernet connection to allow contact between the processor and an Internet time server is the most reliable way to update the system astronomical time clocks to keep the system time accurate in a multiple processor system. Even when not specifically required by the project, Crestron strongly recommends providing an Ethernet connection to the Crestron processor(s) to allow for remote system updates and troubleshooting. If an Ethernet connection cannot be provided Crestron will request a signed waiver noting the understanding that remote access is not being given and additional troubleshooting trips may be required. Static IP addresses or other system-specific configuration that must be implemented on Crestron-provided equipment must be provided to Crestron prior to the technician's arrival onsite. Color Choices Please carefully examine these submittals for notations regarding the color or finish of devices and confirm that all choices are correct. Restocking fees will apply for changing device colors after shipment. System Programming Programming charges include 'Standard' & 'Modified' default keypad and touch screen templates. Additional design fees are required for certain custom graphics. Contact your Crestron Project MANAGER for details and charges. DRAWING SET REVISION HISTORY REV DATE ENG REVISION DESCRIPTION 0 INITIAL SUBMITTAL THIS DRAWING SET IS FORMATTED FOR PRINTING AT "X7" (B-SIZE/TABLOID). IF THIS DRAWING SET HAS BEEN PRINTED AT A SMALLER SIZE AND IS ILLEGIBLE, CONTACT YOUR PROJECT MANAGER. PROJECT: ORDER #: PROJECT LOCATION: PO #: DATE: QUOTE #: REVISION #: SALES REP: 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 TITLE: COVER PAGE AND DRAWING INDEX DRAWING: 0.0 REV: 00 DATE: 0-JUN-0 DISTRIBUTOR:

L:\Lighting\00 - Templates\AutoCAD Blocks\000 - Submittal CAD Blocks\Cover Page and LOT\Crestron-QR.png Crestron Commercial Lighting Control Systems Electronic System Commissioning Request CLCS Commissioning Requests must be received three weeks prior to the time Crestron is to arrive on site. The week lead time is necessary to review all system documentation, ensure that documentation is complete and accurate, obtain any missing information, as well as program the system, prior to arriving on-site. Crestron will not schedule on-site visits, until all information below is verified as being complete by a Crestron Project MANAGER. Please contact your CLCS Project MANAGER to help you complete these forms if you have ANY questions. CANCELLATION POLICY: If a Start-Up Request Form has been submitted and confirmed, and appropriate travel arrangements have been made (ie. flight, train, car rental, hotel, etc.) requestee will be held responsible for all associated cancellation fees. Crestron will invoice purchasee all associated cancellation fees. Failure of back-charge payment will void all system warranty. All Start-Up requests are now completed electronically. Follow the instructions below to download the "Canvas Plus" application for your ios and Droid devices. STEP: Download the Canvas Plus App Instructions For iphone & ipad users, Click on this link: https://itunes.apple.com/us/app/canvas-plus/id80?mt=8 Or scan this QR Code: For Android users, open the Android Marketplace, search for canvas, click and download the canvas plus app created by Canvas Solutions Inc. Or scan this QR Code: For other PC & Mobile Operating Systems: go to this link http://www.gocanvas.com/m and select the mobile operation system you are using. Or scan this QR Code: STEP : Log on User Name: electrical.contractor@crestron.com Password: CrestronEC STEP : Select "Commissioning Form" and click START 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 TITLE: SYSTEM ELECTRONIC COMMISSIONING REQUEST FORM DRAWING: 0.0 REV: 00 DATE: 0-JUN-0.

L:\Lighting\00 - Templates\AutoCAD Blocks\000 - Submittal CAD Blocks\Cover Page and LOT\Crestron-QR.png Crestron Commercial Lighting Control Systems System Commissioning Checklists Hardware Pre-Commissioning Checklist Lighting Control Panel Installation Complete All lighting control cabinets are installed & wired per the project submittals. All required line voltage, low voltage, and control wires are connected to the panel(s). Lighting Fixture/Load Installation Complete All lighting fixtures and loads (motors, shades, fans, etc.) are installed, wired, and checked for short circuits. All loads are capable of being turned on and off at the Crestron Electrical Panel or Crestron Control Module. Any changes to the 'Crestron Load Schedule with Panel Terminations ' (such as load type changes) have been noted and provided to Crestron. If Electrical Contractor changes are not conveyed to Crestron, in-house system programming will not match the site conditions and additional on-site programming will be required. This additional programming will delay the project and may also require additional site visits and applicable fees. Electrical Contractor will be responsible for these fees. Control System 'Load Schedule with Electrical Panel Terminations' Matches on-site Conditions Crestron builds and programs all equipment according to the Crestron ' Load Schedule with Panel Terminations' included in this submittal. If Electrical Contractor determines it is necessary to modify this load schedule, all changes must be provided to Crestron with or no later than your On-Site Commissioning Request. If Electrical Contractor changes are not conveyed to Crestron, in-house system programming will not match the site conditions and additional on-site programming will be required. This additional programming will delay the project and may also require additional site visits and applicable fees. Electrical Contractor will be responsible for these fees. Control System Power Complete There is power to the Crestron Control Processor over appropriate cable as shown in this submittal. Cresnet Device Installation Complete All Crestron devices shown on this submittal's riser are installed and wired per the project submittal, ensuring Crestron Voltage Drop calculations have been adhered to & standard wiring terminations have been finalized. Each Cresnet Device has an associated Serial Number on it. Electrical Contractor is responsible for identifying EACH serial number and its installation location on the project. It is suggested that the Serial Numbers be written on a project plan and sent to Crestron. This information is required in order to program the system. Other Device Installation Complete Third-party manufacturers devices, i.e. Shades, Occupancy Sensors, Photo Sensors, BMS, DMX, etc. that are to be controlled by Crestron are properly installed, wired, commissioned and programmed. Ethernet/IT Network If applicable, the IT network must be functional & configured to allow for traffic to and from Crestron devices, prior to On-Site Field Commissioning Request. Remote System Troubleshooting Access Provided Electrical Contractors installing Crestron systems may be required, per the submittals, to provide VPN or Direct system access for remote diagnostics and testing. This has been provided per the submittals. Wiring per the Latest Addendum If equipment has been added or changed after signed submittals have been received, Electrical Contractor shall verify all wiring with Crestron prior to any installation on site. If you need revised risers, please contact your CLCS Project MANAGER. Notes Compliance All appropriate notes on this submittal package's ' General Notes Page' and individual drawings have been reviewed, addressed, and complied with. Crestron Commercial Lighting Control Systems System Commissioning Checklists Programming Pre-Commissioning Checklist Standard Lighting Control Programming Design Guide All Crestron submittals include a copy of the Crestron ' Standard' Lighting Control Programming Design Guide for the devices on the project. Your project will be designed with these standards unless the Crestron Modified Lighting Control programming Design Guide has been submitted prior to your Start-Up Request. Modified Lighting Control Programming Design Guide All submittals also include a copy of the Crestron ' Modified' Lighting Control Programming Design Guide. If you wish to modify the Crestron programming standards for the project, (create scenes, create multi-function buttons, etc.) simply complete and submit the Modified Lighting Control Programming Design Guide prior to Start-Up Request to CLCService@crestron.com and it will be programmed accordingly. Modified Programming Submission Deadline Any 'Modified' Lighting Control Programming requests received after the On-Site Visit is scheduled will be subject to additional service fees and may delay your On-Site commissioning. Custom Lighting Control Design Templates Crestron touchpanels utilize standard graphic design templates. Please refer to the Crestron website to view these designs. Customization of these touchpanel graphicsare available upon requests for additional design fees. Please send your request in writing to CLCService@crestron.com for an additional quote. Crestron Commercial Lighting Contacts In most situations, the contacts shown on the cover page of this submittal and repeated below will be the best resources for information over the course of this project. If you have any problems getting in touch with them, or for questions that don't seem best directed to those staff members, below are some additional resources for contacting Crestron. CLCQuotes@Crestron.com CLCSubs@Crestron.com CLCOrders@Crestron.com CLCLighting@Crestron.com CLCService@Crestron.com All quote requests, revisions, or general sales questions Engineering questions or questions & comments about submittal documents All NEW orders Business Address: Corporate Offices: 6 Volvo Drive 5 Volvo Drive Rockleigh, NJ 0767 Rockleigh, NJ 0767 General lighting, customer service or order status question, & RMA requests Post-install service issues, tech support, programming, & start-up requests Telephone: Commercial Lighting: 855.6.76 Crestron Main Switchboard: 800.7.0 Fax: 0.767.09 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 TITLE: SYSTEM COMMISSIONING CHECKLISTS & CONTACT INFO DRAWING: 0. REV: 00 DATE: 0-JUN-0.

L:\Lighting\00 - Templates\AutoCAD Blocks\000 - Submittal CAD Blocks\Cover Page and LOT\Crestron-QR.png CRESNET WIRING DETAILS CAUTION: POSSIBLE EQUIPMENT DAMAGE IF MISWI #8 AWG DC GROUND TO PINOUT REFERENCE CONNECTION TO CONTROL PROCESSOR SHIELD / DRAIN (TERMINATE AT CONTROL/ PROCESSOR END ONLY) DRAIN WIRES MUST BE SPLICED AT ALL CONNECTIONS TO EACH NETWORK DEVICE ALONG THE CABLE Y Z G Y Z G () () (WHITE) () G Z Y Y Z G () (WHITE) () () TWISTED PAIR A (/ WHITE) # AWG DATA Z WHITE # AWG DATA Y PARALLEL PAIR B (/) #8 AWG +VDC CRESNET CABLE COLOR CODE - CRESNET CABLE GND Z Y = = = = WHITE DATA PAIR (# AWG TWISTED) POWER PAIR (#8 AWG PARALLEL-STANDARD CABLE) (# AWG PARALLEL-HIGH POWER CABLE) SHIELD / DRAIN CAP-OFF AT END POINT OF CABLE TO LAST NETWORK DEVICE AT END-OF-LINE Y Z G () (WHITE) () () WIRING NOTES DO THIS: DO NOT DO THIS: GENUINE CRESNET CONTROL CABLE IS RECOMMENDED FOR CONNECTION OF CRESTRON COMMERCIAL LIGHTING SYSTEMS. STRIP ONLY THE MINIMUM AMOUNT OF JACKETING FROM THE WIRES, AND INSULATE ANY EXPOSED CONDUCTORS/ DRAIN WIRES WITH HEAT SHRINK TUBING, OR AT A MINIMUM PVC ELECTRICAL TAPE. GROUND SHIELD/DRAIN AT CONTROL PROCESSOR END ONLY. SHIELD/DRAIN MUST BE SPLICED TOGETHER AT EVERY CONNECTION AND CAPPED-OFF AT END OF CONTROL RUN. SHIELD/DRAIN SHOULD NOT CONNECT TO ANY DISTRIBUTION DEVICES (DIN-HUB, DIN-BLOCK, CNTBLOCK) BUT SHOULD BYPASS THE DISTRIBUTION DEVICE, SPLICING ALL REQUI DRAINS TOGETHER AS DONE AT ALL CONNECTIONS ALONG CONTROL CABLE RUNS. WHEN DAISY CHAINING NETWORK UNITS, ALWAYS TWIST THE ENDS OF THE INCOMING WIRE AND THE OUTGOING WIRE THAT SHARE A PIN ON THE NETWORK CONNECTOR. IF NECESSARY USE A PIGTAIL SPLICE WHEN LANDING MORE THAN TWO CONDUCTORS ON A SMALL GREEN PHOENIX CONNECTOR. A PIGTAIL WILL ALWAYS BE REQUI WHEN TERMINATING MULTIPLE "HP" (HIGH-POWER) CABLES INTO ONE CONNECTOR DUE TO THE LARGER POWER CONDUCTORS. MODEL "CNTBLOCK" NETWORK DISTRIBUTION/ TERMINAL BLOCKS ARE RECOMMENDED FOR TESTING PURPOSES AND CONVENIENCE OF WIRING. DO NOT POWER UP SYSTEM UNTIL ALL WIRING IS VERIFIED. CARE SHOULD BE TAKEN TO ENSURE DATA (Y,Z) AND POWER (,G) CONNECTIONS ARE NOT CROSSED. DO NOT CONNECT THE SHIELD/DRAIN WIRE OF ANY CRESNET CABLE TO GROUND AT ANY CONNECTION POINT EXCEPT THE CONTROL PROCESSOR. DO NOT ALLOW ANY EXPOSED SHIELD/DRAIN WIRE TO MAKE CONTACT WITH ANY ELECTRICAL GROUND. IF ANY WIRE IS EXPOSED, IT MUST BE INSULATED- HEAT SHRINK TUBE IS RECOMMENDED, BUT AT A MINIMUM PVC ELECTRICAL TAPE CAN BE USED. DO NOT EXCEED THE "MAXIMUM LENGTH" SHOWN IN THE CABLE IDENTIFICATION BLOCK OF ANY CABLE. 000' IS THE NORMAL MAXIMUM LENGTH THAT WILL BE INDICATED. IN MOST SITUATIONS 500' WILL BE POSSIBLE, BUT IS NOT RECOMMENDED DUE TO POSSIBLE INTERFERENCE & INDUCED VOLTAGE. LONGER CABLE RUNS WILL REQUIRE SIGNAL HUBS OR REPEATERS TO ENSURE SIGNAL RELIABILITY. (SEE NEXT SHEET FOR MORE INFO ON CRESNET POWER.) DO NOT EXCEED 0 CRESNET "DEVICES" ON ANY ONE NETWORK SEGMENT WITHOUT DISCUSSING THE POSSIBLE IMPLICATIONS WITH YOUR CRESTRON PROJECT ENGINEER. (SEE NEXT SHEET FOR MORE INFO ON CRESNET DEVICES.) 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 TITLE: CRESNET WIRING INSTRUCTIONS DRAWING: 0. REV: 00 DATE: 0-JUN-0

UP DOWN NET NET Y Z G Y Z G CN-SDC UP DOWN PWR NET SETUP LOAD SCHEDULE LOAD LOAD TYPE: -WIRE 0-0V DIMMING BALLAST: -WIRE 0-0V DIMMING LOAD LOAD TYPE: -WIRE 0-0V DIMMING BALLAST: -WIRE 0-0V DIMMING LOAD LOAD TYPE: SWITCHED BALLAST: -WIRE SWITCHED LOAD LOAD TYPE: SWITCHED BALLAST: -WIRE SWITCHED + - N SW H + - N SW H TO BUILDING LAN (F.B.O) FOR INTERSYSTEM ETHERNET COMMUNICATIONS REMOTE & LOCAL PROGRAM UPLOADS N H N H LOADS SHOWN ON THIS RISER ARE FOR WIRING REFERENCE ONLY SEE LOAD SCHEDULE ABOVE FOR ACTUAL LOADS NOTE THAT NEUTRAL CONNECTORS FOR ALL CIRCUITS EXCEPT CIRCUIT DO NOT TERMINATE INSIDE GLPAC. CIRCUIT PROVIDES A SMALL AMOUNT OF CONTROL POWER FOR INTERNAL USE IN THE GLPAC AND REQUIRES A NEUTRAL CONNECTION. GLPAC-DIMFLVx SCHEMATIC LINE VOLTAGE SWITCH TERMINALS - 0 VAC OR 77 VAC CRESNET CTRL SYS INPUT CRESNET LOCAL NET OUTPUT 0-0V CURRENT SINK DIMMING TERMINALS USB CONN. RJ5 NET CONN. SETUP CONTROLS OCCUPANCY SENSORS PHOTOCELLS LINE VOLTAGE SWITCH TERMINALS 5-8 0 VAC OR 77 VAC + - N SW H + - N SW H N H N H LOAD LOAD TYPE: -WIRE 0-0V DIMMING BALLAST: NA LOAD LOAD TYPE: -WIRE 0-0V DIMMING BALLAST: NA LOAD LOAD TYPE: SWITCHED BALLAST: -WIRE SWITCHED LOAD LOAD TYPE: SWITCHED BALLAST: -WIRE SWITCHED GLS-LOL PHOTOCELLS OPTIONAL- INDEPENDENT PHOTOCELL INPUTS GLS-LOL GLS-LOL GLS-LCL GLS-LEXT GLS-LOL GLS-LOL GLS-ODT-C-000 OCCUPANCY SENSORS OPTIONAL- INDEPENDENT OCCUPANCY INPUTS SENSORS MAY DAISY-CHAIN GLS-ODT-C-000 FROM ONE INPUT GLS-ODT-C-000 GLS-ODT-C-000 ANY CRESTRON OCCUPANCY SENSOR EXCEPT GLS-ODT-C-CN MAY BE USED STANDARD NOTES:. THIS DOCUMENT SHOWS TYPICAL GLPAC SYSTEM CONNECTIONS. PLEASE SEE YOUR PROJECT BILL OF MATERIALS TO SEE THE EXACT PRODUCTS ON THE ORDER.. LOAD SCHEDULE IS TO BE VERIFIED BY THE ELECTRICAL CONTRACTOR UPON COMPLETION OF INSTALLATION.. AS BUILT LINE MARKUPS OF THE LOAD SCHEDULE MUST BE PROVIDED TO CRESTRON BEFORE SYSTEM PROGRAMMING CAN BE COMPLETED.. THE ELECTRICAL CONTRACTOR, DISTRIBUTOR, OR ELECTRICAL ENGINEER MUST CONFIRM THAT THE FIXTURES SHOWN ARE COMPATIBLE WITH THE TYPE OF SWITCHING OR DIMMING SHOWN ON THIS SCHEDULE. DIMMING A FIXTURE WITH AN INCOMPATIBLE BALLAST MAY CAUSE DAMAGE THAT IS NOT COVE BY WARRANTY. 5. ADDITIONAL TERMINALS- CONTACT CLOSURES AND SIGNAL RELAYS (-PM UNITS ONLY)- ARE NOT NORMALLY USED IN STANDALONE "OUT-OF-BOX" SYSTEMS AND ARE NOT SHOWN HERE. 7. ETHERNET CONNECTIONS TO GLPAC DEVICES ARE NOT REQUI FOR NORMAL SYSTEM OPERATION. IT IS STILL SUGGESTED THAT ETHERNET CABLING BE INSTALLED TO AN EASILY ACCESSIBLE JACK OR ETHERNET PATCH PANEL, AS WITHOUT SUCH A CONNECTION ANY PROGRAM UPDATES OR SYSTEM TROUBLESHOOTING WILL REQUIRE PHYSICAL ACCESS TO THE LOCATION IN WHICH THE GLPAC IS INSTALLED. REGARDLESS OF THE INSTALLATION OF SUCH CABLES, PHYSICAL ACCESS TO EACH GLPAC WILL BE REQUI FOR THE INITIAL SYSTEM COMMISSIONING. GLPAC TYPES GLPAC UNITS ARE AVAILABLE IN THE FOLLOWING SIZES & TYPES GLPAC-DIMFLV GLPAC-DIMFLV-CP GLPAC-DIMFLV-PM GLPAC-DIMFLV-PM-CP GLPAC-DIMFLV8 GLPAC-DIMFLV8-CP GLPAC-DIMFLV8-PM GLPAC-DIMFLV8-PM-CP -CHANNEL SWITCHING OR 0-0V DIMMING SAME AS GLPAC-DIMFLV, BUT IN CHICAGO PLENUM ENCLOSURE SAME AS GLPAC-DIMFLV, ADDS POWER MONITORING & LOW-VOLTAGE RELAY OUTPUTS SAME AS GLPAC-DIMFLV-PM, BUT IN CHICAGO PLENUM ENCLOSURE 8-CHANNEL SWITCHING OR 0-0V DIMMING SAME AS GLPAC-DIMFLV8, BUT IN CHICAGO PLENUM ENCLOSURE SAME AS GLPAC-DIMFLV8, ADDS POWER MONITORING & LOW-VOLTAGE RELAY OUTPUTS SAME AS GLPAC-DIMFLV8-PM, BUT IN CHICAGO PLENUM ENCLOSURE DEVICE POWER A GLPAC CONTROLLER MAY SUPPLY UP TO 0 WATTS OF CRESNET POWER FOR CONSUMPTION BY DEVICES CONNECTED TO LOCAL NET PORT OR SENSOR INPUTS. IF MORE THAN 0 WATTS IS REQUI, AN ADDITIONAL POWER SUPPLY (GLA-PWS50) WILL BE REQUI. CONSULT THE LIST BELOW FOR POWER DRAW OF COMMON DEVICES. PROJECT: ORDER #: PROJECT LOCATION: PO #: DATE: QUOTE #: REVISION #: SALES REP: DISTRIBUTOR: PROJECT NOTES: 0V POWER FEED GLA-PWS50 STATION ID: PS- LOCATION: TBD BY SPECIFIER DWG #: SEE SPEC SHEET 50W POWER SUPPLY OPTIONAL- MAY BE ADDED AS NEEDED ONLY CONNECT CRESNET & GROUND (Y, Z & G) WIRES ONLY CONNECT POWER ( & G) WIRES CN-CBD-P -8 BUTTONS STATION ID: CKP- LOCATION: TBD BY SPECIFIER DWG. #: CN-CBD-P CONTROL KEYPADS OPTIONAL- UP TO 8 PER GLPAC (CN-CBD-P "CAMEO" OR CNX-B "DESIGNER" STYLES) CN-CBD-P CN-SDC -8 BUTTONS STATION ID: SDC- STATION ID: CKP- LOCATION: TBD BY SPECIFIER LOCATION: TBD BY SPECIFIER DWG. #: CN-SDC DWG. #: CN-CBD-P WIRE TYPES: FEED: 0VAC SHADE/DRAPE/SCREEN CONTROLLER OPTIONAL- UP TO 8 PER ILUX "CRESNET" CABLE: () PAIR #8AWG, () TWISTED PAIR AWG W/SHIELD (BY E.C.) NON-PLENUM PN: CRESNET-NP-TL PLENUM PN: CRESNET-P-TL RS- CABLE: () TWISTED PAIR AWG () SHIELD DB-9 CONNECTOR (BY E.C.) TO DEVICES SHADE/DRAPE/SCREEN # SHADE/DRAPE/SCREEN # (NOT ALL TYPES ARE USED ON ALL PROJECTS) 5 TO ADDITIONAL DEVICES AS REQUI CABLE: () TWISTED PAIR 8AWG () SHIELD (BY E.C.) CABLE: CAT5E ETHERNET SUITABLE GAUGE WIRE TO MEET LOAD REQUIREMENTS ALL WIRE RUNS ARE TYPE, CRESNET, UNLESS OTHERWISE NOTED. MAXIMUM CABLE LENGTH EQUATION: L < 0,000 R x P CN-CBD-P CAMEO KEYPAD CNX-B DESIGNER KEYPAD CN-SDC SHADE CONTROL GLS-SIM SENSOR INTERFACE GLS-LOL or LCL PHOTOCELL GLS-ODT or OIR* OCC. SENSOR WATT WATTS WATTS WATT + WATT PER SENSOR CONNECTED TO CRESNET WATT CONNECTED DIRECT WATT CONNECTED DIRECT *GLS-ODT-C-CN CRESNET OCCUPANCY SENSOR IS NOT CURRENTLY SUPPORTED OUT-OF-BOX BUT MAY BE USED IN CUSTOM PROGRAMS. ALL OCCUPANCY SENSORS THAT CONNECT TO CRESNET VIA GLS-SIM INTERFACES ARE COMPATIBLE DIRECTLY CONNECTING TO OCCUPANCY SENSOR TERMINALS WITHOUT A GLS-SIM. Where L = Maximum Length of run in feet from power source R = 6 Ohms for Cresnet Certified wire or.6 Ohms for Cresnet High Power Certified wire P = Cresnet Power usage of entire run SEE CRESNET WIRING INSTRUCTIONS, DWG. 0., FOR FULL DETAILS. LENGTH OF CRESNET WIRING RUNS ARE LIMITED TO # OF DEVICES AND CRESNET POWER DRAW. DAISY CHAIN AND OR STAR TOPOLOGIES ARE PERMITTED TO SUIT INSTALLATION NEEDS. EACH HOME RUN NOT TO EXCEED 0 CRESNET DEVICES. USE THE CALCULATOR SHOWN TO DETERMINE MAXIMUM WIRE RUN LENGTH. POWER SUPPLIES CAN BE ADDED TO INCREASE LENGTH OF HOME RUNS. ALL PHYSICAL DEVICE LOCATIONS TO BE COORDINATED WITH ARCHITECT. 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 TITLE: STANDALONE GLPAC RISER REV: 00 DATE: 0-JUN-0

GLPAC-DIMFLV DIMMING MODULE NOTES KEY N L + - TO LOADS CIRCUIT BREAKER (0A MAX) - BREAKER IS FURNISHED BY ELECTRICAL CONTRACTOR. NEUTRAL BUS BAR - BUS BAR IS INTEGRAL TO CIRCUIT BREAKER PANEL BOARD. () LINE AND () LOAD TERMINAL FOR EACH OF () CIRCUITS. (SCREWS TO BE TORQUED TO 8 IN-LB) NEUTRAL BUS MASTER CRESNET NETWORK CONNECTOR FOR COMMUNICATION TO BUILDING PROCESSOR. 5 EMERGENCY OVERRIDE INPUT FOR UL 9 COMPLIANCE CIRCUIT BREAKER (0A MAX) L Y Z G O G Y Z G 5 6 7 8 5 6 7 8 G G G 0" /8" 6 7 9 LOCAL CRESNET NETWORK CONNECTOR FOR COMMUNICATION LOCAL DEVICES. SIGNAL RELAYS TO HVAC SYSTEMS (PM VERSION ONLY). 8 CONTACT CLOSURES. 0 () OCCUPANCY SENSOR INPUTS. V LOW VOLTAGE POWER PROVIDED. () PHOTO SENSOR INPUTS. V LOW VOLTAGE POWER PROVIDED. ETHERNET CONNECTION FOR SYSTEM CONFIGURATION. 0-0V OUTPUT FOR DIMMING OF FIXTURES. USE CLASS OR CLASS WIRE. 0-0V OUTPUTS MUST CORRESPOND TO LINE OUTPUTS. MINIMUM GAUGE WIRE IS 8AWG. GENERAL NOTES. DO NOT POWER UP SYSTEM UNTIL ALL WIRING IS VERIFIED. CARE SHOULD BE TAKEN TO ENSURE DATA (Y,Z) AND POWER (,G) CONNECTIONS ARE NOT CROSSED. GLPAC-DIMFLV GLPAC-DIMFLV DESCRIPTION: 000 DATE: //0 REVISION: NOTES:. MODULE SHIPS FROM WITH FACTORY INSTALLED JUMPERS ON EACH CIRCUIT. JUMPERS MUST BE REMOVED AT COMMISSIONING. SPECIFICATION INPUT VOLTAGE DIMMER CHANNELS SUPPORTED LOAD TYPES MAXIMUM LOAD LOAD RELAY RATING SIGNAL RELAY RATING ENVIRONMENTAL TEMPERATURE HUMIDITY AVAILABLE CRESNET POWER SPECIFICATIONS DETAILS 00-77 VAC 50/60 Hz FLUORESCENT BALLAST, INCANDESCENT, MAGNETIC LOW VOLTAGE, ELECTRONIC LOW VOLTAGE, NEON/COLD CATHODE, HIGH-INTENSITY DISCHARGE, MOTOR 6A PER OUTPUT 77 VAC, 50A A, 0 VOLTS DC TO 0 F (0 TO 0 C) 0% TO 90% RH, NON-CONDENSING 0 WATTS AT V DC, SHA WITH OCCUPANCY AND PHOTOCELL SENSOR PORTS 5 6 7 8 9 0 " /8" 5. PANEL REQUIRES OVERCURRENT PROTECTION FROM AN EXTERNAL BREAKER PANEL (F.B.O.). TO LAST CONTROL STATION, PROCESSOR, OR CRESNET DEVICE. (SEE CONTROL RISER) CRESNET CONTROL WIRING WHITE Y Z G TO NEXT CONTROL STATION, PROCESSOR, OR CRESNET DEVICE. (SEE CONTROL RISER) 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 GLPAC-DIMFLV DRAWING: OF

INSTALLATION OBSERVE THE FOLLOWING WHEN INSTALLING THE CABINET: NEUTRAL BUS N L + - TO LOADS - THE CABINET MUST BE MOUNTED BY A LICENSED ELECTRICIAN IN ACCORDANCE WITH ALL NATIONAL AND LOCAL CODES. - ALLOW ADEQUATE CLEARANCE (' MINIMUM) IN FRONT OF CABINET FOR SERVICING. - THE CABINET IS DESIGNED FOR SURFACE MOUNTING ON A WALL. - CABINETS ARE INTENDED FOR INDOOR USE ONLY. TORQUE CIRCUIT BREAKER (0A MAX) L LAN: TO CRESNET ETHERNET DEVICES, OTHER CONTROL PROCESSORS, ETC. USB: TO PC TO COMMUNICATE WITH TOOLBOX WHITE PURPLE GRAY TERMINAL LN INPUTS SW INPUTS N, N NEUTRAL BUS 0-0V OUTPUTS* GROUND LUG LV CONNECTORS * LOAD WIRING: CONN. WIRE RANGE -0 AWG -0 AWG -0 AWG 8- AWG - AWG * MAY BE WI AS CLASS OR CLASS TORQUE. LB-IN (0.5Nm). LB-IN (0.5Nm). LB-IN (0.5Nm). LB-IN (0.5Nm) 5-5 LB-IN (.8-5.Nm) STRIP LENGTH 5/6" (8MM) 5/6" (8MM) 5/6" (8MM) 5/6" (8MM) /" (9MM). TURN OFF ALL CIRCUIT BREAKERS. CONNECT THE NEUTRAL BUS AND GROUND LUGS. CONNECT THE INCOMING FEED CONNECTORS TO THE 'LINE' AND 'N' INPUT TERMINALS (REFER TO DIAGRAM) NOTE: WHEN FEEDING FROM A SINGLE BRANCH CIRCUIT, ADDITIONAL LINE TERMINALS ARE PROVIDED TO ALLOW FOR DAISY-CHAINING OF CHANNELS. CONNECT 0-0V CONTROL WIRES FOR THE DIMMED LOADS TO THE APPROPRIATE OUTPUT TERMINALS (-8) 5. TEST THE CIRCUIT FOR ELECTRICAL FAULTS BY TURNING ON EACH CIRCUIT BREAKER, CHECKING THAT THE BREAKERS DO NOT TRIP, AND THAT POWER IS DELIVE TO THE PROPER LOADS NOTE: UNIT REQUIRES 'LINE' AND NEUTRAL TO BE CONNECTED TO POWER UP INPUT WIRING: 6- AWG. LB-IN (0.5Nm) /" (6MM) USE CRESTRON CERTIFIED WIRE SUCH AS CRESNET-NP OR CRESNET-P. TO ENSURE OPTIMUM PERFORMANCE OVER THE FULL RANGE OF YOUR INSTALLATION TOPOLOGY, USE CRESTRON CERTIFIED WIRE. FAILURE TO DO SO MAY INCUR ADDITIONAL CHARGES IF SUPPORT IS REQUI TO IDENTIFY PERFORMANCE DEFICIENCIES BECAUSE OF USING IMPROPER WIRE. GLPAC-DIMFLV GLPAC-DIMFLV DESCRIPTION: 000 DATE: //0 REVISION: NOTES: Y Z G O G Y Z G -- -- -- -- 5 6 7 8 G G G TO CTRL SYS OVRD LOCAL NET SIGNAL RELAYS CONTACT CLOSURES OCC SENSORS PHOTOCELLS SEE DIAGRAM TO THE LEFT FOR WIRING OF REPRESENTATIVE DEVICES. TESTING: MANUAL CONTROL LIGHTING LOADS CAN BE MANUALLY CONTROLLED FROM THE FRONT PANEL WHITE TO CTRL SYS: TO CONTROL SYSTEM CENTRAL CONTROL PROCESSOR OVRD: FROM OTHER CABINET, FROM ALARM, ETC. (OPTIONAL); TO OTHER CABINETS IN NECESSARY WHITE LOCAL NET: TO CRESTRON DEVICES (KEYPADES, TOUCHPANELS, SHADE CONTROLS, ETC.) SIGNAL RELAYS: VAV BOX ( OF ) (PM ONLY) CONTACT CLOSURES: GENERAL PURPOSE INPUT ( OF 8) ROOM OCCUPANCY SENSOR ( OF ) ANALOG PHOTOCELL INPUT ( OF ) OVERRIDE MODE THE OVERRIDE MODE OVERRIDES THE CONTROL SYSTEM PROGRAM AND SETS ALL OF THE OUTPUT STATES TO THE STO OVERRIDE VALUES (SEE BELOW) TO ENABLE OVERRIDE, PRESS AND RELEASE THE 'OVR' BUTTON. THE 'OVR' LED FLASHES SLOWLY NOTE: IF OVERRIDE MODE WAS ENABLED FROM AN EXTERNAL DEVICE (I.E. A CONTACT CLOSURE ON THE 'OVRD' TERMINALS, THE OVR LED WILL FLASH QUICKLY. PRESSING THE OVR BUTTON HAS NO EFFECT. TO DISABLE OVERRIDE MODE, PRES THE OVR BUTTON AGAIN. THE OVR LED EXTINGUISHES AND THE OUTPUTS RETURN TO THE STATES SET BY THE CONTROL PROGRAM. NOTE: IF OVERRIDE STATES HAVE NOT BEEN STO, THE FACTORY DEFAULT IS "ALL ON" SAVE OVERRIDE SETTINGS THE STATE OF ALL OUTPUTS CAN BE SAVED AS AN OVERRIDE SETTING, WHICH IS AUTOMATICALLY RECALLED BY OVERRIDE MODE 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 GLPAC-DIMFLV NOTE: THE CONTROL SYSTEM PROGRAM CAN BE SET TO PREVENT LOCALLY CHANGING THE OVERRIDE STATE. IF THIS SETTING IS ENABLED, THE DISPLAY WILL SHOW "ERR" WHEN TRYING TO SAVE OVERRIDE STATES. TO SAVE THE CURRENT STATE OF ALL OUTPUTS AS THE OVERRIDE SETTING, PRESS AND HOLD THE OVR BUTTON FOR SECONDS, UNTIL THE LED BLINKS ONCE. DRAWING: OF

GLPAC-DIMFLV8 DIMMING MODULE NOTES KEY CIRCUIT BREAKER (0A MAX) - BREAKER IS FURNISHED BY ELECTRICAL CONTRACTOR. N L + - TO LOADS NEUTRAL BUS BAR - BUS BAR IS INTEGRAL TO CIRCUIT BREAKER PANEL BOARD. () LINE AND () LOAD TERMINAL FOR EACH OF (8) CIRCUITS. (SCREWS TO BE TORQUED TO 8 IN-LB) NEUTRAL BUS 5 MASTER CRESNET NETWORK CONNECTOR FOR COMMUNICATION TO BUILDING PROCESSOR. EMERGENCY OVERRIDE INPUT FOR UL 9 COMPLIANCE CIRCUIT BREAKER (0A MAX) L 0" /8" 6 7 9 LOCAL CRESNET NETWORK CONNECTOR FOR COMMUNICATION LOCAL DEVICES. SIGNAL RELAYS TO HVAC SYSTEMS (PM VERSION ONLY). 8 CONTACT CLOSURES. 0 () OCCUPANCY SENSOR INPUTS. V LOW VOLTAGE POWER PROVIDED. () PHOTO SENSOR INPUTS. V LOW VOLTAGE POWER PROVIDED. ETHERNET CONNECTION FOR SYSTEM CONFIGURATION. 0-0V OUTPUT FOR DIMMING OF FIXTURES. USE CLASS OR CLASS WIRE. 0-0V OUTPUTS MUST CORRESPOND TO LINE OUTPUTS. MINIMUM GAUGE WIRE IS 8AWG. GENERAL NOTES. DO NOT POWER UP SYSTEM UNTIL ALL WIRING IS VERIFIED. CARE SHOULD BE TAKEN TO ENSURE DATA (Y,Z) AND POWER (,G) CONNECTIONS ARE NOT CROSSED. GLPAC-DIMFLV8 GLPAC-DIMFLV8 DESCRIPTION: 000 DATE: //0 REVISION: NOTES:. MODULE SHIPS FROM WITH FACTORY INSTALLED JUMPERS ON EACH CIRCUIT. JUMPERS MUST BE REMOVED AT COMMISSIONING. 5 6 7 8 9 0. PANEL REQUIRES OVERCURRENT PROTECTION FROM AN EXTERNAL BREAKER PANEL (F.B.O.). SPECIFICATION INPUT VOLTAGE DIMMER CHANNELS 8 SPECIFICATIONS DETAILS 00-77 VAC 50/60 Hz " /8" TO LAST CONTROL STATION, PROCESSOR, OR CRESNET DEVICE. (SEE CONTROL RISER) CRESNET CONTROL WIRING WHITE TO NEXT CONTROL STATION, PROCESSOR, OR CRESNET DEVICE. (SEE CONTROL RISER) 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 SUPPORTED LOAD TYPES MAXIMUM LOAD LOAD RELAY RATING FLUORESCENT BALLAST, INCANDESCENT, MAGNETIC LOW VOLTAGE, ELECTRONIC LOW VOLTAGE, NEON/COLD CATHODE, HIGH-INTENSITY DISCHARGE, MOTOR 6A PER OUTPUT 77 VAC, 50A Y Z G GLPAC-DIMFLV8 SIGNAL RELAY RATING A, 0 VOLTS DC ENVIRONMENTAL TEMPERATURE HUMIDITY AVAILABLE CRESNET POWER TO 0 F (0 TO 0 C) 0% TO 90% RH, NON-CONDENSING 0 WATTS AT V DC, SHA WITH OCCUPANCY AND PHOTOCELL SENSOR PORTS DRAWING: OF

INSTALLATION OBSERVE THE FOLLOWING WHEN INSTALLING THE CABINET: NEUTRAL BUS N L + - TO LOADS - THE CABINET MUST BE MOUNTED BY A LICENSED ELECTRICIAN IN ACCORDANCE WITH ALL NATIONAL AND LOCAL CODES. - ALLOW ADEQUATE CLEARANCE (' MINIMUM) IN FRONT OF CABINET FOR SERVICING. - THE CABINET IS DESIGNED FOR SURFACE MOUNTING ON A WALL. - CABINETS ARE INTENDED FOR INDOOR USE ONLY. TORQUE CIRCUIT BREAKER (0A MAX) L LAN: TO CRESNET ETHERNET DEVICES, OTHER CONTROL PROCESSORS, ETC. USB: TO PC TO COMMUNICATE WITH TOOLBOX WHITE PURPLE GRAY TERMINAL LN INPUTS SW INPUTS N, N NEUTRAL BUS 0-0V OUTPUTS* GROUND LUG LV CONNECTORS * LOAD WIRING: CONN. WIRE RANGE -0 AWG -0 AWG -0 AWG 8- AWG - AWG * MAY BE WI AS CLASS OR CLASS TORQUE. LB-IN (0.5Nm). LB-IN (0.5Nm). LB-IN (0.5Nm). LB-IN (0.5Nm) 5-5 LB-IN (.8-5.Nm) STRIP LENGTH 5/6" (8MM) 5/6" (8MM) 5/6" (8MM) 5/6" (8MM) /" (9MM). TURN OFF ALL CIRCUIT BREAKERS. CONNECT THE NEUTRAL BUS AND GROUND LUGS. CONNECT THE INCOMING FEED CONNECTORS TO THE 'LINE' AND 'N' INPUT TERMINALS (REFER TO DIAGRAM) NOTE: WHEN FEEDING FROM A SINGLE BRANCH CIRCUIT, ADDITIONAL LINE TERMINALS ARE PROVIDED TO ALLOW FOR DAISY-CHAINING OF CHANNELS. CONNECT 0-0V CONTROL WIRES FOR THE DIMMED LOADS TO THE APPROPRIATE OUTPUT TERMINALS (-8) 5. TEST THE CIRCUIT FOR ELECTRICAL FAULTS BY TURNING ON EACH CIRCUIT BREAKER, CHECKING THAT THE BREAKERS DO NOT TRIP, AND THAT POWER IS DELIVE TO THE PROPER LOADS NOTE: UNIT REQUIRES 'LINE' AND NEUTRAL TO BE CONNECTED TO POWER UP INPUT WIRING: 6- AWG. LB-IN (0.5Nm) /" (6MM) USE CRESTRON CERTIFIED WIRE SUCH AS CRESNET-NP OR CRESNET-P. TO ENSURE OPTIMUM PERFORMANCE OVER THE FULL RANGE OF YOUR INSTALLATION TOPOLOGY, USE CRESTRON CERTIFIED WIRE. FAILURE TO DO SO MAY INCUR ADDITIONAL CHARGES IF SUPPORT IS REQUI TO IDENTIFY PERFORMANCE DEFICIENCIES BECAUSE OF USING IMPROPER WIRE. GLPAC-DIMFLV8 GLPAC-DIMFLV8 DESCRIPTION: 00 DATE: /9/0 REVISION: NOTES: Y Z G O G Y Z G -- -- -- -- 5 6 7 8 G G G TO CTRL SYS OVRD LOCAL NET SIGNAL RELAYS CONTACT CLOSURES OCC SENSORS PHOTOCELLS SEE DIAGRAM TO THE LEFT FOR WIRING OF REPRESENTATIVE DEVICES. TESTING: MANUAL CONTROL LIGHTING LOADS CAN BE MANUALLY CONTROLLED FROM THE FRONT PANEL WHITE TO CTRL SYS: TO CONTROL SYSTEM CENTRAL CONTROL PROCESSOR OVRD: FROM OTHER CABINET, FROM ALARM, ETC. (OPTIONAL); TO OTHER CABINETS IN NECESSARY WHITE LOCAL NET: TO CRESTRON DEVICES (KEYPADES, TOUCHPANELS, SHADE CONTROLS, ETC.) SIGNAL RELAYS: VAV BOX ( OF ) (PM ONLY) CONTACT CLOSURES: GENERAL PURPOSE INPUT ( OF 8) ROOM OCCUPANCY SENSOR ( OF ) ANALOG PHOTOCELL INPUT ( OF ) OVERRIDE MODE THE OVERRIDE MODE OVERRIDES THE CONTROL SYSTEM PROGRAM AND SETS ALL OF THE OUTPUT STATES TO THE STO OVERRIDE VALUES (SEE BELOW) TO ENABLE OVERRIDE, PRESS AND RELEASE THE 'OVR' BUTTON. THE 'OVR' LED FLASHES SLOWLY NOTE: IF OVERRIDE MODE WAS ENABLED FROM AN EXTERNAL DEVICE (I.E. A CONTACT CLOSURE ON THE 'OVRD' TERMINALS, THE OVR LED WILL FLASH QUICKLY. PRESSING THE OVR BUTTON HAS NO EFFECT. TO DISABLE OVERRIDE MODE, PRES THE OVR BUTTON AGAIN. THE OVR LED EXTINGUISHES AND THE OUTPUTS RETURN TO THE STATES SET BY THE CONTROL PROGRAM. NOTE: IF OVERRIDE STATES HAVE NOT BEEN STO, THE FACTORY DEFAULT IS "ALL ON" SAVE OVERRIDE SETTINGS THE STATE OF ALL OUTPUTS CAN BE SAVED AS AN OVERRIDE SETTING, WHICH IS AUTOMATICALLY RECALLED BY OVERRIDE MODE 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 GLPAC-DIMFLV8 NOTE: THE CONTROL SYSTEM PROGRAM CAN BE SET TO PREVENT LOCALLY CHANGING THE OVERRIDE STATE. IF THIS SETTING IS ENABLED, THE DISPLAY WILL SHOW "ERR" WHEN TRYING TO SAVE OVERRIDE STATES. TO SAVE THE CURRENT STATE OF ALL OUTPUTS AS THE OVERRIDE SETTING, PRESS AND HOLD THE OVR BUTTON FOR SECONDS, UNTIL THE LED BLINKS ONCE. DRAWING: OF

NOTES KEY #CN-CBD-P CAMEO SERIES CONTROL STATION WITH LED INDICATORS. SINGLE GANG ELECTRICAL BOX WITH NECESSARY ACCESSORIES,.5" DEEP MINIMUM (NOT BY CRESTRON). 0. IN PAN HEAD SCREW (TYP OF () PER STATION). PROVIDED WITH CONTROL STATION BY CRESTRON. TOP VIEW 5 6 CUSTOM ENGRAVEABLE AND CONFIGURABLE KEYPAD BUTTONS. SEE MANUAL FOR ASSEMBLY INSTRUCTIONS. CRESNET CONNECTION PORT FOR CONTROL VIA -SERIES CONTROL SYSTEM. GROUNDING WIRE FOR KEYPAD TO ELECTRICAL ENCLOSURE. 7 NOT SHOWN: TO BE USED WITH ANY DECORA STYLE FACEPLATE. FURNISHED BY OTHERS. 0 6 8 LED INDICATORS - INDICATE SELECTED SCENE 8 FRONT VIEW SIDE VIEW BACK VIEW 5 9 9 0 -PIN.5MM DETACHABLE TERMINAL BLOCK. COMPRISES OF () VERSIPORT INPUTS. PHOTOSENSOR FOR CONTROL OF AUTO-DIMMING FUNCTION. CAN BE CONFIGU TO REPORT AMBIENT LIGHT LEVEL TO CONTROL SYSTEM. NOTE: KEYPAD IS COMPATIBLE WITH STANDARD DECORA-STYLE FACEPLATE, NOT PROVIDED BY CRESTRON. WIRING NOTES: CAUTION: POSSIBLE EQUIPMENT DAMAGE IF MISWI. DO NOT POWER UP SYSTEM UNTIL ALL WIRING IS VERIFIED. CARE SHOULD BE TAKEN TO ENSURE DATA (Y,Z) AND POWER (,G) CONNECTIONS ARE NOT CROSSED.. GROUND SHIELD AT CONTROL SYSTEM END ONLY.. STRIP ONLY THE MINIMUM AMOUNT OF JACKETING FROM THE WIRES, AND INSULATE EXPOSED CONDUCTORS/ DRAIN WIRES WITH HEAT SHRINK TUBING.. GENUINE CRESNET CONTROL CABLE IS RECOMMENDED FOR CONNECTION OF CRESTRON COMMERCIAL LIGHTING SYSTEMS. CN-CBD-P CN-CBD-P KEYPAD DESCRIPTION: 006 DATE: 7//0 REVISION: NOTES: 5. WHEN DAISY CHAINING NETWORK UNITS, ALWAYS TWIST THE ENDS OF THE INCOMING WIRE AND THE OUTGOING WIRE THAT SHARE A PIN ON THE NETWORK CONNECTOR. IF NECESSARY USE A PIGTAIL WHEN LANDING MORE THAN TWO CONDUCTORS ON A SMALL CONNECTOR. IMPORTANT: SEE INSTALLATION AND OPERATION MANUAL FOR KEYPAD ASSEMBLY INSTRUCTIONS AND BUTTON CONFIGURATION INSTRUCTIONS. IMPORTANT: KEYPADS WILL SHIP FROM THE FACTORY WITH NO BUTTONS INSTALLED. ALL KEYPADS SHIP WITH A COMPLETE SET OF BUTTONS TO FORM ANY OF THE LAYOUTS SHOWN ON THE "MODIFIED" DETAIL PAGE. ANY INFORMATION PROVIDED FOR ENGRAVING OR PROGRAMMING INFORMATION WILL NOT BE IMPLEMENTED UNTIL AFTER SYSTEM COMMISSIONING IS COMPLETE, AT WHICH TIME REPLACEMENT BUTTONS WITH THE SPECIFIED ENGRAVING WILL BE PROVIDED. TO LAST CONTROL STATION, PROCESSOR, OR CRESNET DEVICE. (SEE CONTROL RISER) CRESNET CONTROL WIRING WHITE TO NEXT CONTROL STATION, PROCESSOR, OR CRESNET DEVICE. (SEE CONTROL RISER) 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 CN-CBD-P KEYPAD Y Z G DEVICE: CN-CBD-P CAMEO KEYPAD PHYSICAL DETAILS DRAWING: OF 5

WIRING FOR OPTIONAL VERSIPORT SENSOR INPUTS WHERE CONVENIENT AND APPROPRIATE, VERSIPORT INPUTS MAY BE USED TO CONNECT OCCUPANCY SENSORS OR PHOTOCELLS TO CRESNET NETWORK RATHER THAN USING GLS-SIM INTERFACE MODULE. VDC G VDC G SENSOR SENSOR DEVICE: CN-CBD-P CAMEO KEYPAD VERSIPORT WIRING DRAWING: OF 5 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 CN-CBD-P DESCRIPTION: CN-CBD-P VERSIPORT WIRING REVISION: 00 DATE: /6/ NOTES:

CN-CBD-P KEYPAD ENGRAVING & CONTROL DETAIL SHEET. STANDARD KEYPAD LAYOUTS 5 6 7 7 BUTTON CONFIGURATION ENGRAVING SCHEDULE BUTTON ID ENGRAVING ON SCENE SCENE SCENE 5 OFF 6 7 STATION ID(s): LOCATION(s): COLOR: CONTROL ZONES TO BE CONTROLLED RAISE LOWER TEXTURE OR SMOOTH (CIRCLE ONE) CONTROL ZONES TO BE CONTROLLED STATION ID(s): LOCATION(s): COLOR: CONTROL ZONES TO BE CONTROLLED RAISE LOWER TEXTURE OR SMOOTH (CIRCLE ONE) CONTROL ZONES TO BE CONTROLLED STATION ID(s): LOCATION(s): COLOR: CONTROL ZONES TO BE CONTROLLED RAISE LOWER TEXTURE OR SMOOTH (CIRCLE ONE) CONTROL ZONES TO BE CONTROLLED STATION ID(s): LOCATION(s): COLOR: CONTROL ZONES TO BE CONTROLLED RAISE LOWER TEXTURE OR SMOOTH (CIRCLE ONE) CONTROL ZONES TO BE CONTROLLED PLEASE NOTE: THIS SHEET AND THE SHEETS FOR "MODIFIED" LAYOUTS THAT FOLLOW DO NOT NEED TO BE RETURNED COMPLETED WITH THE SUBMITTAL PACKAGE FOR THIS PROJECT. THESE SHEETS MUST BE RETURNED NOT LATER THAN YOUR REQUEST FOR SYSTEM COMMISSIONING. KEYPADS SHIP WITH NO BUTTONS INSTALLED. SEE NOTE ON CN-CBD-P SHEET OF 5 FOR DETAILS. INSTRUCTIONS IF THESE STANDARD LAYOUTS ARE ACCEPTABLE FOR YOUR PROJECT, PLEASE FOLLOW THE INSTRUCTIONS BELOW. IF YOU NEED TO MODIFY THESE LAYOUTS, PLEASE GO TO THE NEXT SHEET "MODIFIED KEYPAD LAYOUTS". MAKE AS MANY COPIES AS YOU NEED OF THIS SHEET TO BE ABLE TO CREATE AS MANY DIFFERENT CONTROL TYPES AS YOU REQUIRE. NOTE THAT IF YOU HAVE SEVERAL STATIONS THAT ARE THE SAME, YOU MAY LIST MULTIPLE STATION ID NUMBERS IN THE APPROPRIATE SPACE, YOU DON'T NEED A SEPARATE SHEET FOR EACH STATION.. LOOK AT THE SINGLE-LINE RISER DIAGRAMS EARLIER IN THIS SUBMITTAL PACKAGE. EACH KEYPAD WILL HAVE A "STATION ID". NOTE THAT STATION ID IN THE APPROPRIATE SPACE, AS WELL AS THE DEVICE LOCATION. IF THE DEVICE LOCATION ISN'T SPECIFIED, PLEASE TRY TO UPDATE IT.. ON THIS SUBMITTAL'S BILL OF MATERIALS PAGE YOU WILL SEE A LISTING OF ALL KEYPADS, AS WELL AS THEIR COLOR AND FINISH.. IF THE KEYPADS HAVE NOT YET BEEN SHIPPED, YOU MAY CHANGE TO COLOR/FINISH FOR NO ADDITIONAL FEE. NOTE THE COLOR YOU WOULD LIKE THE KEYPAD TO BE ON THE "COLOR" LINE, WITH EITHER "SMOOTH" (GLOSS) OR "TEXTU" (MATTE) ON THE LINE BELOW COLOR. 5. BE AWARE THAT IF THE KEYPADS HAVE SHIPPED AND THE COLOR NEEDS TO CHANGE, RESTOCKING FEES WILL BE APPLIED. CN-CBD-P CN-CBD-P KEYPAD STANDARD LAYOUT & ENGRAVING DESCRIPTION: 00 DATE: /6/ REVISION: NOTES: ENGRAVING SCHEDULE 6. IN THE CONTROL TABLE, ENTER THE INFORMATION REQUI FOR ZONES TO BE CONTROLLED BY THE BUTTONS. BUTTON CONFIGURATION BUTTON ID ENGRAVING ON OFF STATION ID(s): LOCATION(s): COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) CONTROL ZONES TO BE CONTROLLED STATION ID(s): LOCATION(s): COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) CONTROL ZONES TO BE CONTROLLED STATION ID(s): LOCATION(s): COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) CONTROL ZONES TO BE CONTROLLED STATION ID(s): LOCATION(s): COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) CONTROL ZONES TO BE CONTROLLED 7. ONCE YOU ARE FINISHED WITH ALL DETAILS, PLEASE SEND THE SHEET(S) TO LIGHTINGCOMMISSIONING@CRESTRON.COM AVAILABLE COLORS & FINISHES WHITE ALMOND GRAY IVORY DARK ALMOND BROWN LATTE DUSK SMOOTH OR TEXTU SMOOTH OR TEXTU SMOOTH OR TEXTU SMOOTH SMOOTH SMOOTH SMOOTH TEXTU TEXTU PLEASE GO TO WWW.CRESTRON.COM FOR PHOTOS OF THESE COLORS, OR CONTACT YOUR CRESTRON PROJECT COORDINATOR FOR SAMPLES 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 STATION ID(s): LOCATION(s): COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) STATION ID(s): LOCATION(s): COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) STATION ID(s): LOCATION(s): COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) STATION ID(s): LOCATION(s): COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) DEVICE: CN-CBD-P CAMEO KEYPAD "STANDARD" LAYOUTS DRAWING: OF 5

CN-CBD-P KEYPAD ENGRAVING SHEET MODIFIED KEYPAD LAYOUTS 5 6 7 8 8 BUTTON STYLE 5 6 6 BUTTON STYLE 5 5 6 7 7 BUTTON STYLE 5 6 6 BUTTON STYLE 6 5 6 7 7 BUTTON STYLE 5 6 6 BUTTON STYLE 7 5 6 7 7 BUTTON STYLE 5 5 5 BUTTON STYLE 5 6 7 7 BUTTON STYLE 6 5 5 BUTTON STYLE 5 6 6 BUTTON STYLE 8 5 5 BUTTON STYLE 5 6 6 BUTTON STYLE 9 5 5 BUTTON STYLE 5 5 6 6 BUTTON STYLE 0 5 5 BUTTON STYLE 9 5 6 6 BUTTON STYLE 5 5 BUTTON STYLE 0 CN-CBD-P CN-CBD-P MODIFIED LAYOUT & ENGRAVING DESCRIPTION: 007 DATE: /0/0 REVISION: UPDATE AVAILABLE STYLES- OTHER STYLES NOT RENUMBE NOTES: 5 5 BUTTON STYLE BUTTON STYLE BUTTON STYLE 5 BUTTON STYLE BUTTON STYLE BUTTON STYLE BUTTON STYLE BUTTON STYLE 6 BUTTON STYLE 8 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 PLEASE USE THESE STYLES AS A GUIDE TO FILL OUT THE MODIFIED KEYPAD LAYOUT & ENGRAVING FORMS ON THE NEXT PAGE NOTE THAT SEVERAL STYLES HAVE BEEN REMOVED FROM THIS SHEET, BUT STYLE NUMBERS ARE UNCHAINED TO MAINTAIN COMPATIBILITY WITH OLDER SHEETS. DEVICE: CN-CBD-P CAMEO KEYPAD "MODIFIED" LAYOUT DRAWING: OF 5

CN-CBD-P KEYPAD ENGRAVING & CONTROL DETAIL SHEET. MODIFIED KEYPAD LAYOUTS KEYPAD STYLE: STATION ID: LOCATION: COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) SEE PREVIOUS SHEET FOR STYLE NUMBERS BUTTONS ARE CLASSED AS HALF, SINGLE, DOUBLE, OR TRIPLE SPACE. DOUBLE AND TRIPLE SPACE BUTTONS CAN HAVE LINES OF TEXT AND EACH LINE CAN HAVE A MAXIMUM OF 7 CHARACTERS. (SEPARATE LINES WITH /) STANDARD RAISE AND LOWER BUTTONS ARE SHIPPED WITH EACH KEYPAD FOR USE IN THE SPLIT BUTTONS (HALF-WIDTH BUTTONS AT THE BOTTOM). IF YOU WISH ENGRAVING ON THESE BUTTONS ONLY - CHARACTERS, DEPENDING ON CHARACTER WIDTH, WILL FIT ON THESE BUTTONS. KEYPAD STYLE: STATION ID: LOCATION: COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) SEE PREVIOUS SHEET FOR STYLE NUMBERS BUTTONS ARE CLASSED AS HALF, SINGLE, DOUBLE, OR TRIPLE SPACE. DOUBLE AND TRIPLE SPACE BUTTONS CAN HAVE LINES OF TEXT AND EACH LINE CAN HAVE A MAXIMUM OF 7 CHARACTERS. (SEPARATE LINES WITH /) STANDARD RAISE AND LOWER BUTTONS ARE SHIPPED WITH EACH KEYPAD FOR USE IN THE SPLIT BUTTONS (HALF-WIDTH BUTTONS AT THE BOTTOM). IF YOU WISH ENGRAVING ON THESE BUTTONS ONLY - CHARACTERS, DEPENDING ON CHARACTER WIDTH, WILL FIT ON THESE BUTTONS. ENGRAVING SCHEDULE BUTTON ID ENGRAVING 5 6 7 8 ENGRAVING SCHEDULE BUTTON ID ENGRAVING 5 6 7 8 CONTROL ZONES TO BE CONTROLLED CONTROL ZONES TO BE CONTROLLED KEYPAD STYLE: STATION ID: LOCATION: COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) SEE PREVIOUS SHEET FOR STYLE NUMBERS BUTTONS ARE CLASSED AS HALF, SINGLE, DOUBLE, OR TRIPLE SPACE. DOUBLE AND TRIPLE SPACE BUTTONS CAN HAVE LINES OF TEXT AND EACH LINE CAN HAVE A MAXIMUM OF 7 CHARACTERS. (SEPARATE LINES WITH /) STANDARD RAISE AND LOWER BUTTONS ARE SHIPPED WITH EACH KEYPAD FOR USE IN THE SPLIT BUTTONS (HALF-WIDTH BUTTONS AT THE BOTTOM). IF YOU WISH ENGRAVING ON THESE BUTTONS ONLY - CHARACTERS, DEPENDING ON CHARACTER WIDTH, WILL FIT ON THESE BUTTONS. KEYPAD STYLE: STATION ID: LOCATION: COLOR: TEXTURE OR SMOOTH (CIRCLE ONE) SEE PREVIOUS SHEET FOR STYLE NUMBERS BUTTONS ARE CLASSED AS HALF, SINGLE, DOUBLE, OR TRIPLE SPACE. DOUBLE AND TRIPLE SPACE BUTTONS CAN HAVE LINES OF TEXT AND EACH LINE CAN HAVE A MAXIMUM OF 7 CHARACTERS. (SEPARATE LINES WITH /) STANDARD RAISE AND LOWER BUTTONS ARE SHIPPED WITH EACH KEYPAD FOR USE IN THE SPLIT BUTTONS (HALF-WIDTH BUTTONS AT THE BOTTOM). IF YOU WISH ENGRAVING ON THESE BUTTONS ONLY - CHARACTERS, DEPENDING ON CHARACTER WIDTH, WILL FIT ON THESE BUTTONS. ENGRAVING SCHEDULE BUTTON ID ENGRAVING 5 6 7 8 ENGRAVING SCHEDULE BUTTON ID ENGRAVING 5 6 7 8 CONTROL ZONES TO BE CONTROLLED CONTROL ZONES TO BE CONTROLLED PLEASE NOTE: THIS SHEET AND THE SHEETS FOR "STANDARD" LAYOUTS THAT PRECEDE IT DO NOT NEED TO BE RETURNED COMPLETED WITH THE SUBMITTAL PACKAGE FOR THIS PROJECT. THESE SHEETS MUST BE RETURNED NOT LATER THAN YOUR REQUEST FOR SYSTEM COMMISSIONING. KEYPADS SHIP WITH NO BUTTONS INSTALLED. SEE NOTE ON CN-CBD-P SHEET OF 5 FOR DETAILS. INSTRUCTIONS IF YOU WISH TO USE ANY MODIFIED LAYOUTS FOR YOUR PROJECT, PLEASE FOLLOW THE INSTRUCTIONS BELOW. IF YOU WISH STANDARD LAYOUTS ONLY, PLEASE GO TO THE PRIOR SHEET "STANDARD KEYPAD LAYOUTS". MAKE AS MANY COPIES AS YOU NEED OF THIS SHEET TO BE ABLE TO CREATE AS MANY DIFFERENT STATION ENGRAVINGS AS YOU REQUIRE. NOTE THAT IF YOU HAVE SEVERAL STATIONS THAT ARE THE SAME, YOU MAY LIST MULTIPLE STATION ID NUMBERS IN THE APPROPRIATE SPACE, YOU DON'T NEED A SEPARATE SHEET FOR EACH STATION.. ENTER THE STYLE NUMBER (SEE PREVIOUS SHEET FOR STYLES) THAT YOU WOULD LIKE FOR A STATION OR TYPE OF STATION.. LOOK AT THE SINGLE-LINE RISER DIAGRAMS EARLIER IN THIS SUBMITTAL PACKAGE. EACH KEYPAD WILL HAVE A "STATION ID". NOTE THAT STATION ID IN THE APPROPRIATE SPACE, AS WELL AS THE DEVICE LOCATION. IF THE DEVICE LOCATION ISN'T SPECIFIED, PLEASE TRY TO UPDATE IT.. ON THIS SUBMITTAL'S BILL OF MATERIALS PAGE YOU WILL SEE A LISTING OF ALL KEYPADS, AS WELL AS THEIR COLOR AND FINISH. 5. IF THE KEYPADS HAVE NOT YET BEEN SHIPPED, YOU MAY CHANGE TO COLOR/FINISH FOR NO ADDITIONAL FEE. NOTE THE COLOR YOU WOULD LIKE THE KEYPAD TO BE ON THE "COLOR" LINE, WITH EITHER "SMOOTH" (GLOSS) OR "TEXTU" (MATTE) ON THE LINE BELOW COLOR. 6. BE AWARE THAT IF THE KEYPADS HAVE SHIPPED AND THE COLOR NEEDS TO CHANGE, RESTOCKING FEES WILL BE APPLIED. 7. 5. IN THE ENGRAVING TABLE, ENTER THE TEXT YOU WOULD LIKE TO HAVE ENGRAVED ON THE BUTTONS. 8. ONCE YOU ARE FINISHED WITH ALL ENGRAVING DETAILS, PLEASE SEND THE SHEET(S) TO LIGHTINGCOMMISSIONING@CRESTRON.COM 9. PLEASE ENTER PROGRAMMING INFORMATION FOR EACH STATION- ZONES TO BE CONTROLLED BY EACH BUTTON. CONTROLS LIKE "PROJECTION SCREEN UP" OR OTHER NON-ZONE RELATED ACTIONS MAY ALSO BE NOTED. AVAILABLE COLORS & FINISHES WHITE ALMOND GRAY IVORY DARK ALMOND BROWN LATTE DUSK SMOOTH OR TEXTU SMOOTH OR TEXTU SMOOTH OR TEXTU SMOOTH SMOOTH SMOOTH SMOOTH TEXTU TEXTU PLEASE GO TO WWW.CRESTRON.COM FOR PHOTOS OF THESE COLORS, OR CONTACT YOUR CRESTRON PROJECT COORDINATOR FOR SAMPLES CN-CBD-P CN-CBD-P MODIFIED LAYOUT & ENGRAVING DESCRIPTION: 005 DATE: // REVISION: NOTES: 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 DEVICE: CN-CBD-P CAMEO KEYPAD "MODIFIED" LAYOUT INSTRUCTIONS DRAWING: 5 OF 5

FEATURES & INSTALLATION BASICS " AN INSTALLATION GUIDE SHIPS WITH EACH SENSOR. PLEASE SEE THAT DOCUMENT FOR FULL INSTRUCTIONS. THIS SHEET IS INTENDED AS AN OVERVIEW OF CAPABILITIES ONLY. DESCRIPTIONS: THE GLS-LOL IS A PHOTOCELL SENSOR DESIGNED FOR DAYLIGHT HARVESTING APPLICATIONS TO PROVIDE CONTROL OF ROOM LIGHTING BASED ON THE PRESENCE OF NATURAL DAYLIGHT. INTENDED FOR USE WITH AN OPEN-LOOP TYPE SYSTEM, THE GLS-LOL CONTINUALLY MONITORS THE AMOUNT OF DAYLIGHT COMING THROUGH A WINDOW OR SKYLIGHT, ALLOWING ROOM LIGHTING TO BE DIMMED OR SWITCHED OFF WHEN THERE IS SUFFICIENT DAYLIGHT AVAILABLE. THE GLS-LOL CAN BE MOUNTED TO A DRYWALL OR DROP-TILE SURFACE. ITS SIMPLE -WIRE INTERFACE ALLOWS FOR CONNECTION TO A CRESTRON CONTROL SYSTEM VIA A SINGLE VERSIPORT I/O (AVAILABLE ON GLS-SIM INTERFACES, CN-CBD-P "CAMEO" KEYPADS, AS WELL AS CERTAIN PROCESSORS AND OTHER INTERFACE MODULES) OR DIRECT CONNECTION TO GLPAC-DIMFLV OR GLPP INTEGRATED CONTROL DEVICES. 6 " GENERAL NOTES & SPECIFICATIONS. SENSING: FIELD OF VIEW: CENTER OF AXIS: LIGHT SENSITIVITY: 60 DEGREE CONE 5 DEGREES FROM MOUNTING SURFACE TO 6000 FOOT-CANDLES. CONNECTIONS: PLUS: () CAPTIVE SCREW TERMINAL, +VDC INPUT MINUS: () CAPTIVE SCREW TERMINAL, POWER & CONTROL COMMON ARROW: () CAPTIVE SCREW TERMINAL, 0-0VDC CONTROL OUTPUT. CONTROLS: (BEHIND COVER) LIGHT LEVEL RANGE: JUMPER-SELECTABLE -00M 0-000, OR 60-6000 FC. POWER: CURRENT CONSUMPTION: ma @ VOLTS DC CRESNET POWER USAGE: WATT (CRESNET BUS MAY BE USED REGARDLESS OF INTERFACE METHOD) GLS-LOL OPEN LOOP PHOTOCELL DESCRIPTION: 000 DATE: 7/0/0 REVISION: NOTES: 5. HOUSING: CONSTRUCTION: MOUNTING: 6. DIMENSIONS: HEIGHT: DIAMTETER: HIGH-IMPACT INJECTION-MOLDED PLASTIC, WHITE SURFACE MOUNT TO DRYWALL OR DROP-TILE.0 IN. (.05 cm).0 IN, (5.08cm) 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 PHYSICAL DETAILS GLS-LOL OPEN-LOOP PHOTOCELL DRAWING: of

5 GLS-LOL PHOTOCELL PLACEMENT BEFORE INSTALLING THE PHOTOCELL, VERIFY THE DAYLIGHT LEVELS ON A SUNNY DAY AT THE PROPOSED LOCATION OF THE PHOTOCELL. WITH THE LIGHTS SWITCHED OFF, USE A LIGHT METER TO READ THE DAYLIGHT LEVEL. ORIENT THE LIGHT METER IN THE SAME DIRECTION THE PHOTOCELL WILL VIEW. THE LIGHT LEVELS UNDER SUNNY CONDITIONS MUST BE AT LEAST 5FC. IF THE LIGHT LEVELS ARE LESS, YOU SHOULD SELECT ANOTHER LOCATION OR REORIENT THE PHOTOCELL. 5 CABLE TO GLS-SIM OR OTHER INTERFACE PHOTOCELL DISTANCE LIGHT FIXTURE DISTANCE LIGHT FIXTURE THE PHOTOCELL IS DESIGNED FOR MOUNTING IN A DRY LOCATION THAT IS EXPOSED TO DAYLIGHT. THE PHOTOCELL SHOULD NOT BE EXPOSED TO DIRECT ILLUMINATION FROM AN ELECTRIC LIGHT SOURCE. WHERE WINDOWS ARE THE PRIMARY SOURCE OF DAYLIGHT, THE PHOTOCELL TYPICALLY MOUNTS ON THE CEILING BETWEEN THE WINDOW AND THE FIRST ROW OF FIXTURES. THE PHOTOCELL POINTS TOWARD THE WINDOW AT APPROXIMATELY A 5 ANGLE. FOR THE BEST RESULTS, THE DISTANCE FROM THE PHOTOCELL TO THE WINDOW SHOULD BE ABOUT / TO / OF THE DISTANCE FROM THE FIRST LIGHT FIXTURES TO THE WINDOW. 0 0 FOR SKYLIGHT APPLICATIONS, THE PHOTOCELL MOUNTS IN THE LIGHTWELL OF THE SKYLIGHT, ORIENTED TOWARD THE INCOMING DAYLIGHT. TYPICALLY, THE PHOTOCELL IS AIMED TOWARD THE SKYLIGHT. THE LIGHT LEVEL RANGE ADJUSTMENT MAY NEED TO BE CHANGED TO 60-6000 FC FOR SKYLIGHT APPLICATIONS. 60 FIELD OF VIEW SENSOR G WHITE OR ( ) (-) (+) GLS-LOL WITH GLS-SIM THE BASIC CONNECTION DIAGRAM FOR INSTALLING A GLS-LOL PHOTOCELL WITH A GLS-SIM INTERFACE. SET THE FIRST DIP SWITCH ( OR ) FOR THE INPUT "ON" AND THE SECOND DIP SWITCH ( OR ) "OFF". GLS-LOL PLACEMENT SENSOR G WHITE ( ) ( ) (-) (+) SECOND GLS-LOL FIRST GLS-LOL GLS-LOL WITH GLS-SIM WIRING DETAIL (SHA CRESNET CABLE METHOD) IN THIS EXAMPLE, BOTH GLS-LOL SENSORS ARE CONNECTED TO THE SIM WITH THE SAME CRESNET CABLE, WHICH CONTAINS WIRES. SINCE EACH SENSOR ONLY REQUIRES WIRES THEY MAY USE THE SAME CONDUCTORS FOR POWER ( & ) WHILE STILL ALLOWING EACH A SEPARATE CONDUCTOR ( OR WHITE) FOR SIGNAL. EACH SENSOR DETECTS DAYLIGHT AND TURNS ON OR OFF ONLY ITS SPECIFIC LIGHTS INDEPENDENT OF THE OTHER SENSOR. THIS ALLOWS FEWER CABLE RUNS TO SENSORS WITHIN THE SAME PROXIMITY. SPECIAL CARE MUST BE TAKEN WITH THIS METHOD TO INSURE THAT THE TERMINATIONS ARE MADE CORRECTLY OR THE SYSTEM MAY NOT FUNCTION AS DESI. DO NOT CONNECT TWO GLS-LOL SENSORS TO THE SAME INPUT. TWO SENSORS CONNECTED TOGETHER MAY PROVIDE CONFLICTING DATA AND RESULT IN THE SYSTEM NOT OPERATING CORRECTLY. GLS-LOL OPEN LOOP PHOTOCELL DESCRIPTION: 00 DATE: 0/5/0 REVISION: NOTES: WHITE OR ( ) G G 5 6 7 8 I/O Y Z G NET Y Z G PHOTOCELLS G WHITE OR ( ) (-) GLPAC PANELS INCLUDE DEDICATED TERMINALS FOR PHOTCELLS AND OTHER SENSORS. FOUR INDEPENDENT TERMINALS ARE PROVIDED. ALL V AND GROUND TERMINALS ARE CONNECTED IN PARALLEL WITH SIMILAR TERMINALS. SHOULD THERE BE INSUFFICIENT OCCUPANCY SENSOR TERMINALS FOR V IT IS ACCEPTABLE TO USE OTHER V TERMINALS WITHIN THE SAME GLPAC. 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 (-) (+) GLS-LOL WITH OTHER INTERFACES TYPES OTHER INTERFACE TYPES ARE AVAILABLE ON PAC, DIN-I08, DIN-AP AND OTHER DEVICES. ALL FEATURE CONNECTIONS SIMILAR TO THE ONES SHOWN HERE. GLS-LOL WIRING DETAILS (+) GLS-ODT GLS-LOL WITH GLPAC WIRING DETAIL GLS-LOL OPEN-LOOP PHOTOCELL DRAWING: of

NOTE: PHYSICAL APPEARANCE VARIES SLIGHTLY BETWEEN 500 FT², 000 FT², & 000 FT² MODELS. DIFFERENT MODELS MAY HAVE DIFFERENT ARRANGEMENTS OF ULTRASONIC SENSORS. OUTSIDE DIMENSIONS, MOUNTING, AND WIRING ARE IDENTICAL FOR ALL MODELS. 9 6 " SIDE VIEW 6 " KNOB COLOR DIP SWITCH DIP SWITCH SETTINGS BANK A- FUNCTIONS OFF ON A SINGLE/DUAL TECH MODE DUAL TECH SINGLE TECH A* PIR/ULTRASONIC MODE PIR ULTRASONIC A MANUAL MODE AUTO ADAPT ENABLE AUTO ADAPT DISABLE A WALK-THRU DISABLE ENABLED DISABLED DIP SWITCH BANK B- FUNCTIONS OFF ON B OVERRIDE TO ON AUTO MODE LIGHTS FORCED ON B OVERRIDE TO OFF AUTO MODE LIGHTS FORCED OFF B TEST MODE OFF > ON > OFF ENTER/EXIT TEST MODE B LEDs DISABLE LEDs ENABLED LEDs DISABLED *THIS SETTING ONLY USED IN SINGLE TECH MODE KNOB ICON FUNCTION GREEN EAR SETS ULTRASONIC RANGE EYE SETS INFRA RANGE CLOCK DELAYED-OFF TIME SUN AMBIENT LIGHT OVERRIDE (GRAY WIRE CONNECTED) ADJUSTMENT KNOBS A KNOB SETTING FULL CCW = MIN (OFF) FULL CW = MAX FULL CCW = MIN (OFF) FULL CW = MAX FULL CCW = MIN (0 SEC) FULL CW = MAX (0 MIN) FULL CCW = LIGHTS STAY OFF FULL CW = LIGHTS ALWAYS TURN ON RANGE- 00-000 LUX B DEFAULT SETTING 50% 75% 50% (0 MIN.) 00% FEATURES & INSTALLATION BASICS AN INSTALLATION GUIDE SHIPS WITH EACH SENSOR. PLEASE SEE THAT DOCUMENT FOR FULL INSTRUCTIONS. THIS SHEET IS INTENDED AS AN OVERVIEW OF CAPABILITIES ONLY. MODEL DESCRIPTION MODEL/FEATURE BASICS CURRENT CONSUMPTION OPERATING FREQUENCY GLS-ODT-C-500 -WAY DUAL TECH 0mA 0KHz GLS-ODT-C-000 -WAY DUAL TECH 0mA 0KHz GLS-ODT-C-000 -WAY DUAL TECH ma KHz COVERAGE 500 FT² (6.5m²) 000 FT² (9.9m²) 000 FT² (85.8m²) SUGGESTED LOCATION MOUNT IN CORNER/OVER DOORWAY MOUNT IN CENTER OF ROOM/AREA MOUNT IN CENTER OF ROOM/AREA MOUNTING OPTIONS:. DROP CEILING MOUNT USING THREADED ROD (INCLUDED).. DROP CEILING MOUNT USING SCREWS (INCLUDED).. BACK BOX OR SURFACE MOUNT RACEWAY MOUNTING (BOX/RACEWAY FBO). CRESTRON RECOMMENDS USING AN OCTAGONAL " X -/" DEEP BACK BOX FOR THESE SENSORS. A GLS-SIM, IF REQUI, MAY MOUNT INSIDE THE SAME BACKBOX GIVEN SUFFICIENT DEPTH. ALL GLS-ODT-C SENSORS ARE DESIGNED FOR OPTIMAL MOUNTING AT 8'. HEIGHTS OF 8'-0' ARE ACCEPTABLE. SPECIAL-ORDER SENSORS MAY BE ADDED TO AN ORDER FOR AN ADDITIONAL CHARGE ALLOWING MOUNTING HEIGHTS OF UP TO 0'. SEE INSTALLATION INSTRUCTIONS FOR FULL INFORMATION. OPERATION DESCRIPTIONS: DUAL-TECH MODE. THIS IS THE DEFAULT MODE FOR THE SENSOR. PASSIVE INFRA TECHNOLOGY (PIR) TURNS LIGHTS ON IN THIS MODE; HOWEVER, MOTION DETECTION BY EITHER TECHNOLOGY (PIR OR ULTRASONIC) WILL KEEP THE LIGHTS ON. IF NEITHER TECHNOLOGY DETECTS MOTION, THE LIGHTS WILL TURN OFF AFTER THE DELAYED-OFF TIME. SINGLE-TECH MODE. ONLY ONE TECHNOLOGY IS ACTIVE IN THIS MODE. THE TECHNOLOGY IS SELECTED BY THE DIP SWITCHES. MOTION DETECTION BY THE SELECTED TECHNOLOGY (PIR OR ULTRASONIC) WILL TURN THE LIGHTS ON AS WELL AS KEEP THEM ON. WHEN MOTION IS NOT DETECTED, THE LIGHTS WILL TURN OFF AFTER THE DELAYED-OFF TIME. GLS-ODT-C-x OCCUPANCY SENSOR- 500, 000, 000 SQ. FT. RANGE DESCRIPTION: 000 DATE: 6//0 REVISION: NOTES: TOP VIEW BOTTOW VIEW (BOTTOM COVER REMOVED) DELAYED-OFF TIME. THE SENSOR IS DESIGNED TO TURN THE LIGHTS OFF IF NO MOTION IS DETECTED FOR A SPECIFIED TIME. THIS LENGTH OF TIME IS CALLED THE DELAYED-OFF TIME AND IS SET USING THE TIMER () KNOB ON THE SENSOR. THE ADAPTING PATTERNS WILL MODIFY THE DELAYED-OFF TIME TO FIT THE PARAMETERS OF EACH INSTALLATION BASED ON THE ENVIRONMENTAL CONDITIONS AND OCCUPANCY PATTERNS. PHYSICAL DETAILS NOTES KEY IR SENSOR AND INTEGRATED PHOTOSENSOR. ULTRASONIC SENSORS (QUANTITY VARIES PER MODEL) MODE SETTING DIP SWITCHES ADJUSTMENT KNOBS WALK-THRU MODE. THE WALK-THRU FEATURE IS USEFUL WHEN A ROOM IS MOMENTARILY OCCUPIED. WITH THIS FEATURE, THE SENSOR WILL TURN THE LIGHTS OFF SHORTLY AFTER THE PERSON LEAVES THE ROOM. THE WALK-THRU FEATURE WORKS AS FOLLOWS: WHEN A PERSON ENTERS THE ROOM THE LIGHTS WILL TURN ON. IF THE PERSON LEAVES THE ROOM BEFORE THE WALK-THRU TIME-OUT OF.5 MINUTES, THE SENSOR WILL TURN THE LIGHTS OFF. IF THE PERSON REMAINS IN THE ROOM LONGER THAN.5 MINUTES THE SENSOR WILL PROCEED TO OCCUPIED MODE AND THE DELAY-OFF TIME WILL BE USED. LED OPERATION. THERE ARE TWO LED INDICATORS THAT WILL FLASH WHEN MOTION IS DETECTED. THE LED FLASH CAN BE DISABLED USING THE LED DISABLE SWITCH SETTING. GREEN FLASHES INDICATE MOTION DETECTED BY ULTRASONIC TECHNOLOGY; FLASHES INDICATE MOTION DETECTION BY INFRA TECHNOLOGY. 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 GLS-ODT-C-x (-500, -000, OR -000) OCCUPANCY SENSOR DRAWING: of

FIELD OF VIEW RANGES- GLS-ODT-C-500 TOP VIEW FIELD OF VIEW RANGES- GLS-ODT-C-000 TOP VIEW 0 FIELD OF VIEW RANGES- GLS-ODT-C-000 TOP VIEW 6.5 CONFERENCE ROOM CONFERENCE ROOM CORRIDOR 0 SIDE VIEW Major Motion, IR Minor Motion, Ultrasonic Major Motion, Ultrasonic SENSOR G WHITE OR FIRST GLS-ODT GRAY (CAP OFF*) SIDE VIEW GRAY (CAP OFF*) SECOND GLS-ODT (OPTIONAL- MAX PER INPUT) Major Motion, IR Minor Motion, Ultrasonic Major Motion, Ultrasonic GLS-ODT (ALL TYPES) WITH GLS-SIM WIRING DETAIL SET BOTH DIP SWITCHES ON THE GLS-SIM FOR THE INPUT THE SENSOR IS CONNECTED TO "ON".5 6 0 8 0 5 9 5.5 0 5.5 9 5 0.5.5 GLS-ODT-C SERIES FIELD OF VIEW RANGES IN THIS EXAMPLE, THE OPTIONAL SECOND GLS-ODT SENSOR IS CONNECTED WITH THE FIRST. EITHER SENSOR WILL ACTIVATE LIGHTING IF IT DETECTS OCCUPANCY, AND NEITHER MAY DETECT OCCUPANCY BEFORE LIGHTING IS DEACTIVATED. SENSOR G WHITE SIDE VIEW SECOND GLS-ODT GRAY (CAP OFF*) Major Motion, IR Minor Motion, Ultrasonic Major Motion, Ultrasonic FIRST GLS-ODT TWO EXAMPLES- MOUNTING & MASKING OPTIONS: IN THE EXAMPLE ABOVE TWO CONFERENCE ROOMS ARE ALONG A CORRIDOR. IT IS UNDESIRABLE FOR CORRIDOR TRAFFIC TO TURN ON THE LIGHTS IN THE CONFERENCE ROOMS. IN THE ROOM ON THE LEFT, A 500 FT² OCCUPANCY SENSOR IS MOUNTED IN A CORNER, COVERING THE ROOM BUT NOT THE CORRIDOR. IN THE ROOM ON THE RIGHT, A 000 FT² OR 000² SENSOR IS LOCATED OVER THE CENTER OF THE ROOM. THIS SENSOR HAS A MASK INSTALLED SIMILAR TO THE ONE BELOW WHICH PREVENTS THE SENSOR FROM SEEING CORRIDOR TRAFFIC WHILE STILL COVERING MOST OF THE ROOM. EACH SENSOR IS SUPPLIED WITH ONE HALF-MASK, PERFORATED IN INCREMENTS THAT MAY BE LEFT IN PLACE OR REMOVED TO MASK OR REVEAL CERTAIN AREAS. NOTE THAT THE MASK IS PRE-INSTALLED TO SHOW THE MOUNTING METHOD AND SHOULD BE REMOVED IF NOT REQUI. GRAY (CAP OFF*) GLS-ODT (ALL TYPES) WITH GLS-SIM WIRING DETAIL (SHA CRESNET CABLE METHOD) SET ALL DIP SWITCHES ON THE GLS-SIM TO "ON" IN THIS EXAMPLE, BOTH GLS-ODT SENSORS ARE CONNECTED TO THE SIM WITH THE SAME CRESNET CABLE, WHICH CONTAINS WIRES. SINCE EACH SENSOR ONLY REQUIRES WIRES THEY MAY USE THE SAME CONDUCTORS FOR POWER ( & ) WHILE STILL ALLOWING EACH A SEPARATE CONDUCTOR ( OR WHITE) FOR SIGNAL. EACH SENSOR DETECTS OCCUPANCY AND TURNS ON OR OFF ONLY ITS SPECIFIC LIGHTS INDEPENDENT OF THE OTHER SENSOR. THIS ALLOWS FEWER CABLE RUNS TO SENSORS WITHIN THE SAME PROXIMITY. SPECIAL CARE MUST BE TAKEN WITH THIS METHOD TO INSURE THAT THE TERMINATIONS ARE MADE CORRECTLY OR THE SYSTEM MAY NOT FUNCTION AS DESI. GLS-ODT-C-x OCCUPANCY SENSOR- 500, 000, 000 SQ. FT. RANGE DESCRIPTION: 00 DATE: 0//0 REVISION: NOTES: WHITE OR GRAY (CAP OFF*) G G 5 6 7 8 I/O NET Y Z G Y Z G GLS-ODT (ALL TYPES) WITH OTHER INTERFACES TYPES OTHER INTERFACE TYPES ARE AVAILABLE ON PAC, DIN-I08, DIN-AP AND OTHER DEVICES. ALL FEATURE CONNECTIONS SIMILAR TO THE ONES SHOWN HERE. OCC SENSORS G *GRAY WIRE MAY BE CONNECTED INSTEAD OF WIRE IF USE OF INTERNAL PHOTOSENSOR IS DESI. PHOTOSENSOR IS NOT NORMALLY UTILIZED AND DOES NOT OFFER THE FULL FUNCTIONALITY OF A GLS-LOL PHOTOSENSOR. GLS-ODT-C SERIES WIRING DETAILS WHITE OR GLS-ODT GRAY (CAP OFF*) GLS-ODT (ALL TYPES) WITH GLPAC WIRING DETAIL GLPAC PANELS INCLUDE DEDICATED TERMINALS FOR OCCUPANCY AND OTHER SENSORS. FOUR INDEPENDENT TERMINALS ARE PROVIDED. ALL V AND GROUND TERMINALS ARE CONNECTED IN PARALLEL WITH SIMILAR TERMINALS. SHOULD THERE BE INSUFFICIENT OCCUPANCY SENSOR TERMINALS FOR V IT IS ACCEPTABLE TO USE OTHER V TERMINALS WITHIN THE SAME GLPAC. 5 Volvo Drive Rockleigh NJ 0767 Tel: 888-7-7876 Fax: 0-767-60 GLS-ODT-C-x (-500, -000, OR -000) OCCUPANCY SENSOR DRAWING: of

CN-SDC Shade and Drape Controller, 0V AC The CN-SDC is a -channel Shade and Drape Controller designed to provide a convenient and cost-effective solution for controlling a variety of motorized window treatments as well as motorized doors, sunroofs, lifts and projection screens. The CN-SDC is a Cresnet device with two independently controlled 0V AC outputs. Each output provides up/down or open/close control of a conventional three-wire bidirectional type motor. Built-in timing and interlock logic make it easy to program the CN-SDC for failsafe operation. The CN-SDC mounts in the wall or ceiling using an off-the-shelf square or -gang electrical box. Pushbuttons on the front of the unit allow for manual operation of the motors during installation and setup. SPECIFICATIONS Load Ratings Motor Control Channels: Per Channel: 7.5 Amps, / HP Total: 5 Amps Load Types: -Wire 0V AC bidirectional motors Power Requirements Line Power: 0 Volts AC, 50-60Hz, single-phase Cresnet Power Usage: Watts (0.5 Amps @ Volts DC) Connections (rear) Hot: () Class flying lead, AWG, black, line power input Neutral: () Class flying lead, AWG, white, neutral Ground: () Class flying lead, AWG, green, ground Load - : () -pin terminal blocks comprising () independent 0V AC -wire bidirectional motor control outputs; Includes terminals for up/open drive (U), down/close drive (D), common/ neutral (C), and ground; Maximum Wire Size: AWG Connectors (front) NET: () -pin.5mm detachable terminal blocks; Cresnet slave ports, paralleled; Connect to Cresnet control network LED Indicators PWR: (green) Indicates DC power supplied from Cresnet network NET: (yellow) Indicates communication with the Cresnet system SETUP: (red) used for touch-settable ID (TSID) Environmental Temperature: to F (5 to 50 C) Humidity: 0% to 90% RH (non-condensing) Enclosure Flat metal plate mountable in a -inch square or -gang electrical box,.5 inch minimum depth; mount -gang box horizontally to maintain correct orientation Dimensions Height:.0 in (0. mm) Width:.0 in (0. mm) Depth:.5 in (9. mm) Weight 0.55 lb (0.5 kg) Buttons UP/DOWN: () buttons for local control of output # UP/DOWN: () buttons for local control of output # SETUP: () button used for touch-settable ID (TSID) crestron.com 800.7.0

CN-SDC Shade and Drape Controller, 0V AC MODELS & ACCESSORIES Available Models CN-SDC: Shade and Drape Controller, outputs for 0 VAC -wire bidirectional motors Available Accessories CRESNET-HP-NP: Cresnet High-Power Control Cable, non-plenum CRESNET-NP: Cresnet Control Cable, non-plenum CRESNET-P: Cresnet Control Cable, plenum Notes: This product may be purchased from an authorized Crestron dealer. To find a dealer, please contact the Crestron sales representative for your area. A list of sales representatives is available online at /salesreps or by calling 800-7-0. Specifications subject to change without notice. Crestron is not responsible for errors in typography or photography. Crestron, the Crestron logo, and Cresnet are trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and other countries. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. 0 Crestron Electronics, Inc. crestron.com 800.7.0

CN-SDC Shade and Drape Controller, 0V AC CAD DRAWINGS Crestron Electronics, Inc. 5 Volvo Drive Rockleigh, NJ 0767 Tel: 800.7.0 / 0.767.00 Fax: 0.767.90 All Crestron products are proudly manufactured in the United States. All brand names, product names and trademarks are the property of their respective owners. 0 Crestron Electronics, Inc. Specifications subject to change without notice. Revised 0/7/

GLS-LOL Crestron Green Light Photocell, Open-Loop > > Photocell sensor that mounts to a wall or ceiling > > Measure the light level from a natural daylight source > > Vertical or horizontal surface mount > > 60 degree field of view > > 0 to 0 Volt DC analog control output > > Control system interface via Cresnet [] or analog input > > EMerge Alliance Compatible The GLS-LOL is a photocell sensor designed for daylight harvesting applications to provide control of room lighting based on the presence of natural daylight. Intended for use with an open-loop type system, the GLS-LOL continually monitors the amount of daylight coming through a window or skylight, allowing room lighting to be dimmed or switched off when there is sufficient daylight available. Open-loop photocell sensing provides a cost-effective solution for daylight harvesting, allowing multiple lighting zones to be controlled by a single sensor. In a typical office, classroom, or similar space, the GLS-LOL is installed on the ceiling near a window, or in the light well of a skylight, directed toward the incoming daylight and away from any electrical lighting fixtures. The system estimates the total amount of ambient lighting in the room according to the light level measured by the photocell. The GLS-LOL can be mounted to a drywall or drop-tile surface. Its simple -wire interface allows for direct connection to a Crestron control system via a single Versiport I/O or analog input port, with Volt power taken from the Cresnet control bus []. Using the optional GLS-SIM Sensor Integration Module, the GLS-LOL becomes a full-featured Cresnet device, streamlining the total lighting system. Cresnet provides a simpler solution for configuring and wiring sensors as part of any complete Crestron system. Cresnet is the communications backbone for Crestron lighting dimmers, keypads, touch screens, shades, thermostats, and many other devices. This flexible -wire bus provides data communications and Volts DC power for all of the devices on the Cresnet network. Emerge Alliance Registered This device is EMerge Alliance registered and designed to work within a VDC room-level power distribution system. The EMerge Alliance is a non-for-profit open industry association leading the rapid adoption of safe DC power distribution in commercial buildings through the development of Emerge Alliance standards [5]. Crestron is a proud member and supporter of the Alliance. For more information about Crestron Solutions for EMerge Alliance Applications visit: /emerge. SPECIFICATIONS Sensing Field of View: 60 degree cone Center Axis: 5 degrees from mounting surface Light Sensitivity: to 6000 foot-candles Connections [,] Plus: () captive screw terminal, + Volt DC power input Minus: () captive screw terminal, Power and control signal common Arrow: () captive screw terminal, Light level control signal output, 0-0 Volts DC Controls (Behind Cover) Light Level Range: Jumper-selectable -00, 0-000, or 60-6000 fc Power Requirements Current Consumption: ma @ Volts DC Cresnet Power Usage: Watt [] Housing Construction: Plastic, white Mounting: Surface mounts directly to drywall or drop-tile Dimensions Height:.0 in (.05 cm) Diameter:.0 in (5.08 cm) crestron.com 800.7.0

GLS-LOL Crestron Green Light Photocell, Open-Loop MODELS & ACCESSORIES Available Models GLS-LOL: Crestron Green Light Photocell, Open-Loop Available Accessories GLS-SIM: Crestron Green Light Sensor Integration Module Notes:. Cresnet communications requires GLS-SIM Sensor Integration Module (sold separately).. Recommended Wire Size: AWG.. Connects to a GLS-SIM Integration Module or to a Versiport I/O or Analog Input control port on any Crestron control system.. Power may be taken from Cresnet bus regardless of interface method. 5. Information regarding the EMerge Alliance can be found at www.emergealliance.org. This product may be purchased from an authorized Crestron dealer. To find a dealer, please contact the Crestron sales representative for your area. A list of sales representatives is available online at /salesreps or by calling 800-7-0. The specific patents that cover Crestron products are listed online at: patents.crestron.com. Crestron, the Crestron logo, Cresnet and Crestron Green Light are trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. EMerge Alliance and the EMerge Alliance logo are either trademarks or registered trademarks of EMerge Alliance Corporation in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. Specifications are subject to change without notice. 0 Crestron Electronics, Inc. Crestron Electronics, Inc. 5 Volvo Drive Rockleigh, NJ 0767 Tel: 800.7.0 / 0.767.00 Fax: 0.76790 All Crestron products are proudly manufactured in the United States. All brand names, product names and trademarks are the property of their respective owners. 0 Crestron Electronics, Inc. Specifications subject to change without notice. Revised 0/8/

GLS-ODT-C-000 Dual-Technology Ceiling Mount Occupancy Sensor, 000 Sq. Ft. > > Ceiling mount occupancy sensor > > Dual-technology motion detection > > 60 degree, 000 square feet coverage > > Discreet, low-profile appearance > > Extremely accurate and reliable sensing > > Microprocessor-controlled self-adapting operation > > Fully-digital circuitry for low cost and high reliability > > Built-in ambient light recognition > > Control system interface via Cresnet [] or Versiport I/O input > > EMerge Alliance Compatible Crestron Green Light sensors deliver a powerful and cost-effective solution for reducing energy costs and enhancing the functionality of lighting and environmental systems. The GLS-ODT-C-000 is a low-profile ceiling mount occupancy sensor designed for large areas up to 000 square feet to detect when the room is occupied. Advanced self-adaptive, dual-technology motion sensing affords extreme reliability for control of lighting, climate control and other devices in the room. Dual-Technology Occupancy Sensing Achieving consistent and dependable occupancy sensing is accomplished using a combination of ultrasonic and passive infrared technologies. Ultrasonic motion detection achieves high sensitivity to small movements over a large area, while passive infrared ensures superior immunity to false triggering from air currents, inanimate objects, or movement in an adjacent corridor. The GLS-ODT-C-000 allows independent sensitivity adjustment of each sensor type for optimum performance in any space. Self-Adaptive Adjustment Under the control of its internal microprocessor, the GLS-ODT-C-000 continually analyzes occupancy behavior and environmental conditions in the room, adjusting itself for optimal functionality so lights turn on and stay on while the room is occupied, and remain off when no one is present. Sensor sensitivity and delayed-off time adjustments are optimized automatically based on day-to-day use of the room to prevent false-on and off conditions. A walk-thru mode provides specialized behavior in instances of brief occupancy, turning lights off quickly when a person enters and exits the room within a period of.5 minutes. Ambient Light Recognition A built-in photocell is included for detection of natural daylight in the room. When enabled, the photocell can override the occupancy sensor if the ambient light level is above a set threshold, preventing lights from turning on when there is sufficient daylight in the room. Versatile Installation The GLS-ODT-C-000 is designed to achieve a discreet, nearly hidden appearance when installed on a typical drywall or drop-tile ceiling. Hardware is included for fast and simple mounting to either surface, or to a standard -inch octagon box. Its simple -wire interface allows for direct connection to a Crestron control system via a single Versiport I/O input port, with Volt power taken from the Cresnet control bus []. Cresnet Option Cresnet provides a simpler solution for configuring and wiring sensors as part of any complete Crestron system. Cresnet is the communications backbone for Crestron lighting dimmers, keypads, touchpanels, shade controllers, thermostats, and many other devices. This flexible -wire bus provides data communications and Volts DC power for all of the devices on the Cresnet network. Using the optional GLS-SIM Sensor Integration Module, the GLS-ODT-C-000 becomes a full-featured Cresnet device, streamlining the total lighting system. Additional features enable quick and easy setup for use with a Crestron IPAC or ilux system. Emerge Alliance Registered This device is EMerge Alliance registered and designed to work within a VDC room-level power distribution system. The EMerge Alliance is a non-for-profit open industry association leading the rapid adoption of safe DC power distribution in commercial buildings through the development of Emerge Alliance standards []. Crestron is a proud member and supporter of the Alliance. For more information about Crestron Solutions for EMerge Alliance Applications visit: /emerge. SPECIFICATIONS Sensing Sensor Technology: Dual-Technology Passive Infrared and Ultrasonic khz Auto-Adjustment: Microprocessor-based self-adaptive Ambient Light Recognition: Built-in photocell for ambient light override Coverage Area: 000 sq. ft. Coverage Pattern: 60 degrees Major Motion Area: 6 x feet Minor Motion Area: 5 x feet crestron.com 800.7.0

GLS-ODT-C-000 Dual-Technology Ceiling Mount Occupancy Sensor, 000 Sq. Ft. Memory Environmental Built-in non-volatile memory retains all settings in case of power loss LED Indicators IR: () Red LED, indicates infrared motion Ultrasonic: () Green LED, indicates ultrasonic motion Controls (Behind Cover) Ultrasonic Range: () Green adjustment knob; Adjusts sensitivity of ultrasonic motion sensor; Adjustment Range: 0% to 00% (50% factory default) Infrared Range: () Red adjustment knob; Adjusts sensitivity of infrared motion sensor; Adjustment Range: 0% to 00% (75% factory default) Delayed-Off Time: () Black adjustment knob; Adjusts delayed-off time duration; Adjustment Range: 0 seconds to 0 minutes (0 minutes factory default, 6 seconds in test mode) Ambient Light Threshold: () Blue adjustment knob; Adjusts threshold for ambient light override; Adjustment Range: 00 to 000 Lux (000 Lux factory default) DIP Switch A: () -position DIP switch : Enables single-technology mode; : Selects infrared or ultrasonic when in single-technology mode; : Disables auto-adapting;. Disables walk-thru mode DIP Switch B: () -position DIP switch : Forces control signal output high (room lights on); : Forces control signal output low (room lights off); : Enters or exits Test Mode (toggle on then off ); : Disables both LED indicators Connections Power: () Red 6 flying lead, AWG; + Volt DC power input Common: () Black 6 flying lead, AWG; Power and control signal common Occupancy: () Blue 6 flying lead, AWG; Occupancy sensor control signal output; Provides Volts DC high logic signal when occupancy is detected; Short circuit protected; Connects to a GLS-SIM Integration Module [], or to a Versiport I/O control port on any Crestron control system Occupancy w/photocell: () Gray 6 flying lead, AWG; Occupancy sensor control signal output with ambient light override; Provides Volts DC high logic signal when occupancy is detected and ambient light is below set threshold; Short circuit protected; Used instead of the blue Occupancy connection when ambient light override is desired Temperature: to 0 F (0 to 0 C) Humidity: 0% to 95% RH (non-condensing) Power Requirements Current Consumption: ma @ Volts DC Cresnet Power Usage: Watt [] Housing Construction: High-impact injection-molded plastic, white Mounting: Surface mount directly to drop-tile or drywall, octagon box (.5 minimum depth), or round fixture box (Wiremold V578 or equivalent) Dimensions Height:.55 in (.9 cm) Diameter:.0 in (0.67 cm) Weight 5.0 oz ( g) Standards & Certifications CUL/US Listed 90, ANCE Compliant, NOM 057, California Title Code Compliant, ASHRAE Standard 90. Compliant, FCC Compliant MODELS & ACCESSORIES Available Models GLS-ODT-C-000: Crestron Green Light Dual-Technology Ceiling Mount Occupancy Sensor, 000 Sq. Ft. Available Accessories GLS-SIM: Crestron Green Light Sensor Integration Module Notes:. Power may be taken from Crestnet bus regardless of interface method.. Cresnet communication requires GLS-SIM Sensor Integration Module (sold separately).. Information regarding the EMerge Alliance can be found at www.emergealliance.org This product may be purchased from an authorized Crestron dealer. To find a dealer, please contact the Crestron sales representative for your area. A list of sales representatives is available online at /salesreps or by calling 800-7-0. Specifications subject to change without notice. Crestron is not responsible for errors in typography or photography. Crestron, the Crestron logo, Crestron Green Light, Cresnet and ilux are trademarks or registered trademarks of Crestron Electronics, Inc. in the United States, other countries or both. EMerge Alliance is a trademark or registered trademark of the EMerge Alliance in the United States, other countries or both. Other trademarks and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims proprietary interest in the marks and names of others. 0 Crestron Electronics, Inc. crestron.com 800.7.0

GLS-ODT-C-000 Dual-Technology Ceiling Mount Occupancy Sensor, 000 Sq. Ft. COVERAGE DIAGRAMS TOP VIEW 0 6.5 0.5 6 0 8 SIDE VIEW Major Motion, IR Minor Motion, Ultrasonic Major Motion, Ultrasonic 0 5 9 5.5 0 5.59 5 0.5.5 Crestron Electronics, Inc. 5 Volvo Drive Rockleigh, NJ 0767 Tel: 800.7.0 / 0.767.00 Fax: 0.767.90 crestron.com All brand names, product names and trademarks are the property of their respective owners. 0 Crestron Electronics, Inc. Specifications subject to change without notice. Revised 0/07/

GLA-PWS50 Wall Mount 50 Watt Cresnet Power Supply The GLA-PWS50 is a 50 Watt Cresnet Power Supply designed for use with a Crestron Green Light system, or anywhere a wall-mountable Cresnet power supply is needed. The GLA-PWS50 mounts conveniently over a " square or -gang electrical box. All connections are made inside the electrical box via flying leads using twist-on wire connectors. A partition is included to isolate high voltage from Class wiring within the box. > 50 Watt Cresnet power supply > Powers the IPAC and other Cresnet devices > Provides backup power for Crestron Green Light cabinets > Mounts to a " square or -gang electrical box > Euro/UK mountable version also available (GLA-PWSI50) SPECIFICATIONS Output Power Output Power: 50 Watts (. Amps) @ Volts DC, regulated, limited power source Ripple/Noise: <% Power Requirements Line Power: Amp @ 00-0 Volts AC, 50/60 Hz Depth:.7 in (5.76 cm) without partition Weight. lb (0.5 kg) Available Models GLA-PWS50: Wall Mount 50 Watt Cresnet Power Supply Connections Line Power: () 6 flying leads, 8 AWG, line power input; Hot (black), neutral (white), and ground (green w/yellow) connections Output: () 6 flying leads, 8 AWG, Cresnet power output; Volts DC (red) and Ground (black w/white); Connects to and G connections of the Cresnet control network, or directly to a Volt DC powered Crestron device Fuse: DC output fuse, T.5AH; (5x0mm, 50V,.5A, time-lag, ceramic cartridge) LED Indicators VDC: () green LED, indicates Volts DC output, extinguishes when fuse is blown Environmental Temperature: to 0 F (0 to 0 C) Humidity: 0% to 90% RH (non-condensing) Heat Dissipation: 6 BTU/hr Enclosure Metal construction, mounts to a -inch square or -gang electrical box, includes low-voltage partition Dimensions Height:.00 in (0.6 cm) Width: 5.55 in (.09 cm) 800.7.0

GLA-PWS50 Wall Mount 50 Watt Cresnet Power Supply Crestron Electronics, Inc. 5 Volvo Drive Rockleigh, NJ 0767 Tel: 800.7.0 / 0.767.00 Fax: 0.767.905 All brand names, product names and trademarks are the property of their respective owners. 0 Crestron Electronics, Inc. Specifications subject to change without notice. 6/6/0

GLPAC-DIMFLV Crestron Green Light Integrated Lighting System > > Up to 8 channels of 0-0 Volt fluorescent and LED dimming > > Works in 00 to 77 VAC systems > > 6-Amp load rating per channel > > Built-in Control System with Cresnet and Ethernet port > > Preloaded program for quick setup > > Optional real-time power monitoring > > Supports keypad control, occupancy sensing, and daylight harvesting for up to rooms > > Positive air gap at each output > > Phase-independent channels > > Local controls for setup, testing, and verification > > Local and remote override capability > > Non-volatile power failure memory > > High-speed Ethernet LAN port The GLPAC-DIMFLV is a Crestron Green Light integrated lighting system, designed for use as a standalone lighting controller in classrooms, conference rooms, and offices. While able to control or 8 channels of dimmable fluorescent loads, each GLPAC-DIMFLV also provides a link to a centralized Crestron lighting control system for control and monitoring. Add optional real-time power monitoring and Crestron Fusion EM Energy Management Software to help track and minimize energy usage throughout a facility. Cresnet and Ethernet connectivity afford extensive system configuration using keypads, touch screens, shade controllers, and more. Flexibility Each GLPAC-DIMFLV can be used to control a single room, or up to four independent rooms. Single-room control is available right out of the box, with no additional configuration. Multi-room control and other system adjustments are accomplished using local controls on the GLPAC-DIMFLV or via the built-in web interface. And because the GLPAC-DIMFLV is a Crestron -Series control processor, limitless customization is possible for specialized applications. Save Energy Built-in support for occupancy and photo sensors helps to strike a perfect balance between daylight harvesting and comfort, reducing energy costs. Automatically turn off lights in unoccupied areas and maintain balanced bulb brightness with the natural light level in the room. Crestron GLS sensors can be placed strategically in each space to maximize the benefits of energy management. Built-in Power Monitoring Optional power monitoring tracks the real time energy usage of each load, thereby delivering statistics to help control energy costs. By analyzing real data, organizations can make more educated decisions regarding energy resources, which will have greater impact on the bottom line. GLPAC-DIMFLV8 shown in photo Easy Deployment Packaged in one metal enclosure, the GLPAC-DIMFLV can be deployed in small spaces, including plenum ceilings. The surface-mount GLPAC-DIMFLV can be affixed to a wall or ceiling rafter, cleanly out of sight. Standard wire-entry knockouts are provided. For more information on Crestron Green Light commercial lighting products, please contact Crestron Sales Support Services. SPECIFICATIONS Load Ratings Dimmer Channels: GLPAC-DIMFLV(-PM): GLPAC-DIMFLV8(-PM): 8 Per Channel: 6 Amps @ 00 to 77 Volts AC, 50/60 Hz Dim Load Types: 0-0 Volt fluorescent ballast (-wire); 0-0V LED drivers; 60 ma max current sink Switch Load Types: Fluorescent Ballast, Incandescent, Magnetic Low-Voltage, Electronic Low-Voltage, Neon/Cold Cathode, High-Intensity Discharge, LED, Motor Relay Lifetime: Resistive rating: 00,000 on/off operations, 50A @ 77 VAC; General rating: 50,000 on/off operations, 6A @ 0/77 VAC Power Requirements Main Power: 00-77 Volts AC, 50/60Hz, supplied via channel (LINE, NEUT) Available Cresnet Power: 0 Watts at Volts DC, shared with occupancy and photocell sensor ports Connectors (Class ) -Channel Models Only NEUT: () terminal blocks, paralleled, line input neutral LINE - LINE : (8) terminal blocks, paralleled, line power inputs SW - SW: () terminal blocks, switch channel outputs crestron.com 800.7.0

GLPAC-DIMFLV Crestron Green Light Integrated Lighting System 0-0V DIM (+,-) -: () 8 position terminal block, dim channel output, galvanically isolated; may be wired as Class or Class Connectors (Class ) 8-Channel Models Only NEUT: () terminal blocks, paralleled, line input neutral LINE - LINE 8: (6) terminal blocks; connections per channel, paralleled, allows for easy daisy chaining; line power inputs SW - SW8: (8) terminal blocks, switch channel outputs 0-0V DIM (+,-) -8: () 8 position terminal block, dim channel output, gavanically isolated; may be wired as Class or Class Connectors (Class ) NET SLAVE: () -pin.5mm detachable terminal block; Cresnet ports for connection to main control processor or other GLPAC-DIMFLVs, does not output Volts DC OVR: () -pin.5mm detachable terminal block, comprising () inputs for external contact closures to trigger the preset Override state NET LOCAL: () -pin.5mm detachable terminal block; Cresnet ports for connection to local devices such as keypads, shade controllers, and touch screens; outputs Volts DC RELAY - (-PM models only): () 8-pin.5mm detachable terminal blocks comprising () normally open, isolated relays; Programmable or used for interfacing to local Variable Air Volume box to indicate room occupancy; Rated Amp, 0 Volts DC INPUT -8: () 9-pin.5mm detachable terminal block comprising (8) digital input ports, referenced to ground OCCUPANCY SENSOR INPUT -: () 6-pin.5mm detachable terminal block comprising () occupancy sensor inputs, () +VDC, and () GND port (provides sensors with power) PHOTOCELL -: () 6-pin.5mm detachable terminal block comprising () photocell sensor inputs, () +VDC, and () GND port (provides sensors with power); Min-change setting can be adjusted to control how often sensor reports changes in values USB: () USB Type B console port, for communication with Crestron Toolbox LAN: () 8-wire RJ5 with LED indicators; 0/00BaseT Ethernet port; Green LED indicates link status; Yellow LED indicates Ethernet activity Controls & Indicators MODE: () 7-Segment green LED digits and () miniature pushbuttons for setting mode during setup or local control VALUE: () 7-Segment green LED digits and () miniature pushbuttons for setting value SAVE: () Red LED and () miniature pushbutton for saving settings CANCEL: () Red LED and () miniature pushbutton for cancelling current operation PWR: () Green LED; solid illumination indicates line power is applied to NEUT and LINE HW-R: () Recessed miniature pushbutton for hardware reset (reboots the processor) SW-R: () Recessed miniature pushbutton for software reset (restarts the SIMPL program) NET-C: () Yellow LED; indicates communication with main control processor (if being used) NET-L: () Yellow LED; indicates communication with local devices MSG: () Red LED; indicates control system has generated an error message OVR: () Red LED and () miniature pushbutton for enabling override mode ON/OFF: (8) Red LEDs and (8) miniature pushbuttons for individual manual channel activation and dimming Enclosure Surface mount metal box enclosure, suitable for mounting in plenum airspace Environmental Temperature: to 0 F (0 to 0 C) Humidity: 0% to 90% RH (non-condensing) Dimensions Height:. in (08 mm) Width:. in (59 mm) Depth:.06 in (0 mm) Electrical Regulatory Certifications Relays tested and certified for Electronic Ballasts according to UL508, Section (Endurance Test) and Section 6C (Electronic Ballasts) IEC60669--, Section 9.0 (Contact mechanisms incorporated in electronic switches, intended for fluorescent lamp circuits or other capacitive loads) CE UL9 Listed upon request MODELS & ACCESSORIES Available Models GLPAC-DIMFLV: Green Light Integrated Lighting System, -Channel GLPAC-DIMFLV-CP: Green Light Integrated Lighting System, -Channel w/chicago Plenum Enclosure GLPAC-DIMFLV-PM: Green Light Integrated Lighting System, -Channel w/power Monitoring GLPAC-DIMFLV-PM-CP: Green Light Integrated Lighting System, -Channel w/power Monitoring & Chicago Plenum Enclosure GLPAC-DIMFLV8: Green Light Integrated Lighting System, 8-Channel GLPAC-DIMFLV8-CP: Green Light Integrated Lighting System, 8-Channel w/chicago Plenum Enclosure GLPAC-DIMFLV8-PM: Green Light Integrated Lighting System, 8-Channel w/power Monitoring GLPAC-DIMFLV8-PM-CP: Green Light Integrated Lighting System, 8-Channel w/power Monitoring & Chicago Plenum Enclosure crestron.com 800.7.0

GLPAC-DIMFLV Crestron Green Light Integrated Lighting System Available Accessories CNX-BB Series: Designer Keypads CN-CBD-E Series: Cameo Express Keypads, Standard Mount CN-CBD-P Series: Cameo Keypads, Standard Mount CN-CBF-P Series: Cameo Keypads, Flush Mount GLS-SIM: Crestron Green Light Sensor Integration Module GLS-LEXT: Crestron Green Light Photocell, Outdoor GLS-LOL: Crestron Green Light Photocell, Open-Loop GLS-LCL: Crestron Green Light Photocell, Closed-Loop GLS-ODT-C-CN: Dual-Technology Occupancy Sensor with Cresnet, 000 Sq. Ft. GLS-OIR-C-CN: Passive Infrared Occupancy Sensor with Cresnet GLS-ODT-C-500: Crestron Green Light Dual-Technology Ceiling Mount Occupancy Sensor, 500 Sq. Ft GLS-ODT-C-000: Crestron Green Light Dual-Technology Ceiling Mount Occupancy Sensor, 000 Sq. Ft. GLS-ODT-C-000: Crestron Green Light Dual-Technology Ceiling Mount Occupancy Sensor, 000 Sq. Ft. GLS-ODT-W-00: Crestron Green Light Dual-Technology Wall Mount Occupancy Sensor, 00 Sq. Ft. GLS-OIR-C-50: Crestron Green Light Passive Infrared Ceiling Mount Occupancy Sensor, 50 Sq. Ft. GLS-OIR-C-500: Crestron Green Light Passive Infrared Ceiling Mount Occupancy Sensor, 500 Sq. Ft. GLS-OIR-W-500: Crestron Green Light Passive Infrared Wall Mount Occupancy Sensor, 500 Sq. Ft. GLS-PLS-0/77: Power Loss Sensor, -Phase, 0 or 77 Volts DIN-PWS50: DIN Rail 50 Watt Cresnet Power Supply GLA-PWS50: Wall Mount 50 Watt Cresnet Power Supply Notes: This product may be purchased from an authorized Crestron dealer. To find a dealer, please contact the Crestron sales representative for your area. A list of sales representatives is available online at /salesreps or by calling 800-7-0. The specific patents that cover Crestron products are listed online at: patents.crestron.com. Crestron, the Crestron logo, Cresnet, Crestron Green Light, Crestron Toolbox, and Crestron Fusion EM are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. Specifications are subject to change without notice. 0 Crestron Electronics, Inc. crestron.com 800.7.0

GLPAC-DIMFLV Crestron Green Light Integrated Lighting System CAD DRAWING (GLPAC-DIMFLV8-PM SHOWN) crestron.com 800.7.0

GLPAC-DIMFLV Crestron Green Light Integrated Lighting System APPLICATION DIAGRAM Crestron Electronics, Inc. 5 Volvo Drive Rockleigh, NJ 0767 Tel: 800.7.0 / 0.767.00 Fax: 0.767.90 All brand names, product names and trademarks are the property of their respective owners. 0 Crestron Electronics, Inc. Specifications subject to change without notice. Revised 05/0/

CN-CBD-P Cameo Keypad, Standard Mount > > Stylish and versatile wall mount keypad > > Standard electrical box installation > > color-matched smooth and textured finishes > > Ascent solid metal faceplates available separately [] > > Versatile combinations of to 8 pushbuttons > > Installer-configurable with choice of button sizes > > Split buttons for up/down and on/off functions [] > > Button Events enable tap, double-tap, and hold functionality > > Customizable backlit button engraving [] > > White LED feedback indicators > > Built-in LED blinking and bargraph logic > > Auto-dimmable backlight and LED intensity > > Ambient light sensor > > Dual digital/analog input ports for external sensors > > Quick and easy installation > > Cresnet wired communications > > EMerge Alliance compatible The Cameo Standard Mount Keypad (CN-CBD-P) from Crestron presents a fresh, innovative concept in keypad design, featuring a highly configurable one-gang wall mount form factor that is at once inviting to the touch and appealing to the eye. The CN-CBD-P easily installs alongside other low-voltage in-wall devices to deliver an advanced custom keypad control solution as part of a complete Crestron control system. Customizable Buttons Exquisitely simple yet highly customizable, a single Cameo Keypad can be configured easily by the installer to provide from two to eight buttons. Each keypad is actually furnished with an assortment of button caps in four different sizes to support a variety of physical layouts. Button caps may also be ordered with custom backlit laser engraving to clearly designate each button s function. [] Through programming, each button can be configured to use button events, affording up to three separate functions per button by tapping, double-tapping, or holding the button. Shift key functionality is even possible, allowing any button to be held while pressing another. Auto-dimming Backlight High-quality backlit laser-engraving [] provides customizable button text that s easy to read under any lighting condition. A built-in light sensor controls the backlight intensity automatically to achieve a crisp, legible appearance in both darkened and fully lit rooms. Actual colors may vary. crestron.com 800.7.0

CN-CBD-P Cameo Keypad, Standard Mount Enhanced LED Feedback Six pinhead-sized white LEDs afford fully customizable feedback to show the status of each button. Ten blink patterns are built in, enabling blinking LED feedback with simplified programming and reduced traffic on the Cresnet network. Onboard bargraph logic allows the feedback LEDs to function as a 6-segment bargraph display, providing clear level indication while adjusting lighting and audio settings. Auto-dimming LED intensity ensures optimal visibility under varying lighting conditions. Ambient Light Sensor In addition to controlling the backlight and LED intensity, the built-in light sensor can also be utilized by the control system to support basic daylight harvesting and other programmatic functions. Control Ports Dual digital/analog input ports onboard the CN-CBD-P provide a local interface for a range of devices including Crestron GLS Occupancy Sensors and Photocells, or any device providing a contact closure, DC logic, or 0-0VDC analog voltage. Using the control ports, it s possible to add monitoring of room occupancy, ambient light level, door closures, and other conditions without having to home run extra wiring to the central equipment location. Cresnet Reliable wired connectivity is afforded via the Cresnet network, utilizing a simple -conductor interface carrying Volt DC power and bidirectional communications between the Cameo keypad and Crestron control system. Cresnet supports up to 5 keypads and other devices. Standard Wall Mount Cameo Standard Mount Keypads are designed for installation in a standard electrical wall box, perfect for installation in a multi-gang box alongside other low-voltage devices. Available in a selection of Smooth and Textured finishes, Cameo Keypads match perfectly with popular off-theshelf decorator-style faceplates. Ascent Metal Faceplates For the ultimate in style and elegance, Crestron offers the Ascent collection of solid metal faceplates (CBD-FP-ASCENT [] ), providing Cameo keypads with a contemporary appearance in a range of luxurious designer finishes. EMerge Alliance Registered This device is EMerge Alliance registered and designed to work within a VDC room-level power distribution system. The EMerge Alliance is a not-for-profit open industry association leading the rapid adoption of safe DC power distribution in commercial buildings through the development of EMerge Alliance standards []. Crestron is a proud member and supporter of the Alliance. For more information about Crestron Solutions for EMerge Alliance Applications visit: /emerge. SPECIFICATIONS Buttons Keypad Buttons: Configurable for to 8 single-action pushbuttons Button Events: Programmable for Normal, Tap, Double-Tap, and Hold Button Caps: Includes () large, () medium, (5) small, and ( pair) split small button caps []. All button caps are blank. Custom backlit engraved button caps are available separately. Backlight: White LED backlight for button engraving, software-adjustable intensity, auto-dimmable LED Indicators Feedback: (6) White LEDs, one per each of 6 small button positions; Programmable, auto-dimmable, software-adjustable intensity, 0 blinking patterns Bargraph: () 6-segment bargraph display utilizing the 6 feedback LEDs Light Sensor Photosensor for control of auto-dimming function; Can be configured to report ambient light level to control system Connectors NET: -pin.5mm detachable terminal block; Cresnet slave port, connects to Cresnet control network INPUT : () -pin.5mm detachable terminal block comprising () digital/analog input ports (referenced to GND); Digital Input: Rated for 0- Volts DC, input impedance 00k Ohms, logic threshold. Volts DC; Analog Input: Rated for 0-0 Volts DC, protected to Volts DC maximum, input impedance 00k Ohms; Programmable 5 Volts, k Ohms pull-up resistor per pin Power Requirements Cresnet Power Usage: Watt (0.05 Amps @ Volts DC) Environmental Temperature: to F (0 to 5 C) Humidity: 0% to 90% RH (non-condensing) Heat Dissipation:. BTU/Hr Construction Chassis: Plastic Mounting: Mounts in a -gang or larger electrical box or mud ring Faceplates: Requires a decorator style faceplate (not included) or Crestron CBD-FP-ASCENT series faceplate [] crestron.com 800.7.0

CN-CBD-P Cameo Keypad, Standard Mount Dimensions Notes: Height:. in (05 mm) without faceplate Width:.75 in (5 mm) without faceplate Depth:.9 in ( mm) without connector Weight. oz (6 g) MODELS & ACCESSORIES Available Models CN-CBD-P-A-S: Cameo Keypad, Standard Mount, Almond Smooth CN-CBD-P-A-T: Cameo Keypad, Standard Mount, Almond Textured CN-CBD-P-B-S: Cameo Keypad, Standard Mount, Black Smooth CN-CBD-P-B-T: Cameo Keypad, Standard Mount, Black Textured CN-CBD-P-BRN-S: Cameo Keypad, Standard Mount, Brown Smooth CN-CBD-P-DA-S: Cameo Keypad, Standard Mount, Dark Almond Smooth CN-CBD-P-DSK-T: Cameo Keypad, Standard Mount, Dusk Textured CN-CBD-P-GRY-S: Cameo Keypad, Standard Mount, Gray Smooth CN-CBD-P-IVR-S: Cameo Keypad, Standard Mount, Ivory Smooth CN-CBD-P-LAT-T: Cameo Keypad, Standard Mount, Latte Textured CN-CBD-P-W-S: Cameo Keypad, Standard Mount, White Smooth CN-CBD-P-W-T: Cameo Keypad, Standard Mount, White Textured. Custom engraving sold separately.. Item(s) sold separately.. Information regarding the EMerge Alliance can be found at www.emergealliance.org. Split small buttons may be installed in the bottom two positions only. This product may be purchased from an authorized Crestron dealer. To find a dealer, please contact the Crestron sales representative for your area. A list of sales representatives is available online at /salesreps or by calling 800-7-0. The specific patents that cover Crestron products are listed online at: patents.crestron.com. Crestron, the Crestron logo, Ascent, Cameo, and Cresnet are either trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other countries. EMerge Alliance and the EMerge Alliance logo are either trademarks or registered trademarks of EMerge Alliance Corporation in the United States and/or other countries. Other trademarks, registered trademarks, and trade names may be used in this document to refer to either the entities claiming the marks and names or their products. Crestron disclaims any proprietary interest in the marks and names of others. Crestron is not responsible for errors in typography or photography. Specifications are subject to change without notice. 0 Crestron Electronics, Inc. Available Accessories CB-BTN: Large Backlit Engravable Button Cap for Cameo Keypads, [Specify Color] CB-BTN: Medium Backlit Engravable Button Cap for Cameo Keypads, [Specify Color] CB6-BTN: Small Backlit Engravable Button Cap for Cameo Keypads, [Specify Color] CB6S-BTN: Split Small Backlit Engravable Button Cap Pair for Cameo Keypads, [Specify Color] CBD-FP-ASCENT: Ascent Solid Metal Faceplate for Cameo Keypad, Standard Mount [specify button layout and finish] CCR-L-: Crestron Color Ring CCR-FP-ASCENT-: Ascent Color Ring CRESNET-HP-NP: Cresnet High-Power Control Cable, non-plenum CRESNET-NP: Cresnet Control Cable, non-plenum CRESNET-P: Cresnet Control Cable, plenum crestron.com 800.7.0

CN-CBD-P Cameo Keypad, Standard Mount Crestron Electronics, Inc. 5 Volvo Drive Rockleigh, NJ 0767 Tel: 800.7.0 / 0.767.00 Fax: 0.767.90 All brand names, product names and trademarks are the property of their respective owners. 0 Crestron Electronics, Inc. Specifications subject to change without notice. Revised 0/7/