Imaging ultrasound field and shear wave propagation using acoustooptic laser speckle contrast analysis (AO-LASCA)

Similar documents
BIOMEDICAL ULTRASOUND

Synthetic Sensing: Proximity / Distance Sensors

A Guide to Acousto-Optic Modulators

Acousto-optic modulator

Laser-induced surface phonons and their excitation of nanostructures

arxiv:astro-ph/ v1 15 Sep 2005

Hunting Bats. Diagnostic Ultrasound. Ultrasound Real-time modality

Waves - Transverse and Longitudinal Waves

Optical Coherence Tomography detection of shear wave propagation. in layered tissue equivalent phantoms

Ultrasonic Wave Propagation Review

Introduction to acoustic imaging

Scanning Near Field Optical Microscopy: Principle, Instrumentation and Applications

Acoustic GHz-Microscopy: Potential, Challenges and Applications

Development of Optical Wave Microphone Measuring Sound Waves with No Diaphragm

Advancements in High Frequency, High Resolution Acoustic Micro Imaging for Thin Silicon Applications

Lab 9: The Acousto-Optic Effect

Principles of Medical Ultrasound. Pai-Chi Li Department of Electrical Engineering National Taiwan University

A pulse is a collection of cycles that travel together. the cycles ( on or transmit time), and. the dead time ( off or receive time)

AS COMPETITION PAPER 2008

Introduction to Optics

Ultrasound Distance Measurement

LBS-300 Beam Sampler for C-mount Cameras. YAG Focal Spot Analysis Adapter. User Notes

On the beam deflection method applied to ultrasound absorption measurements

7. DYNAMIC LIGHT SCATTERING 7.1 First order temporal autocorrelation function.

DESIGN AND EVALUATION OF PROBE WITH THREE DEGREE- OF-FREEDOM FOR NON-DESTRUCTIVE TEST USING THREE- DIMENSIONAL FINITE ELEMENT METHOD

Optical Communications

Robot Perception Continued

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

Optical Fibres. Introduction. Safety precautions. For your safety. For the safety of the apparatus

OPTICAL FIBERS INTRODUCTION

STATISTICAL ANALYSIS OF ULTRASOUND ECHO FOR SKIN LESIONS CLASSIFICATION HANNA PIOTRZKOWSKA, JERZY LITNIEWSKI, ELŻBIETA SZYMAŃSKA *, ANDRZEJ NOWICKI

Module 13 : Measurements on Fiber Optic Systems

Rock Bolt Condition Monitoring Using Ultrasonic Guided Waves

Polarization of Light

Revision problem. Chapter 18 problem 37 page 612. Suppose you point a pinhole camera at a 15m tall tree that is 75m away.

Study of the Human Eye Working Principle: An impressive high angular resolution system with simple array detectors

PIPELINE LEAKAGE DETECTION USING FIBER-OPTIC DISTRIBUTED STRAIN AND TEMPERATURE SENSORS WHITE PAPER

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Antennas & Propagation. CS 6710 Spring 2010 Rajmohan Rajaraman

VECTORIAL ELECTRIC FIELD MONTE CARO SIMULA- TIONS FOR FOCUSED LASER BEAMS (800 nm 2220 nm) IN A BIOLOGICAL SAMPLE

v = fλ PROGRESSIVE WAVES 1 Candidates should be able to :

Today. next two weeks

AP Physics B Ch. 23 and Ch. 24 Geometric Optics and Wave Nature of Light

Doppler. Doppler. Doppler shift. Doppler Frequency. Doppler shift. Doppler shift. Chapter 19

Scanning Near-Field Optical Microscopy for Measuring Materials Properties at the Nanoscale

Optical Metrology. Third Edition. Kjell J. Gasvik Spectra Vision AS, Trondheim, Norway JOHN WILEY & SONS, LTD

TISSUE MIMICKING GEL QUALITY LE PHANTOM SERIES DESIGN. performance the ultrasound labs ofand. icking material has the same attenuation mim-

Physical Science Study Guide Unit 7 Wave properties and behaviors, electromagnetic spectrum, Doppler Effect

MEASURING THE 3D PROPAGATION OF SOUND WAVES USING SCANNING LASER VIBROMETRY

Ultrasonic Echosignal Applied to Human Skin Lesions Characterization

Encoders for Linear Motors in the Electronics Industry

Advances in scmos Camera Technology Benefit Bio Research

The promise of ultrasonic phased arrays and the role of modeling in specifying systems

Lecture 14. Point Spread Function (PSF)

Limiting factors in fiber optic transmissions

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

A More Efficient Way to De-shelve 137 Ba +

10ème Congrès Français d'acoustique Lyon, Avril 2010

RAY TRACING UNIFIED FIELD TRACING

Endoscope Optics. Chapter Introduction

Original Research Articles

Modern Classical Optics

A Measurement of 3-D Water Velocity Components During ROV Tether Simulations in a Test Tank Using Hydroacoustic Doppler Velocimeter

physics 1/12/2016 Chapter 20 Lecture Chapter 20 Traveling Waves

It has long been a goal to achieve higher spatial resolution in optical imaging and

Waves Sound and Light

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

E190Q Lecture 5 Autonomous Robot Navigation

Nano Meter Stepping Drive of Surface Acoustic Wave Motor

Self-Mixing Laser Diode Vibrometer with Wide Dynamic Range

APPLICATION NOTE AP050830

Projects. Objective To gain hands-on design and measurement experience with real-world applications. Contents

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

High-quality/High-resolution Digital Ultrasound Diagnostic Scanner

Theremino System Theremino Spectrometer Technology

A PHOTOGRAMMETRIC APPRAOCH FOR AUTOMATIC TRAFFIC ASSESSMENT USING CONVENTIONAL CCTV CAMERA

Laboratory #3 Guide: Optical and Electrical Properties of Transparent Conductors -- September 23, 2014

- thus, the total number of atoms per second that absorb a photon is

Describing Sound Waves. Period. Frequency. Parameters used to completely characterize a sound wave. Chapter 3. Period Frequency Amplitude Power

Using light scattering method to find The surface tension of water

Incoherent beam combining using stimulated Brillouin scattering in multimode fibers

Holographically corrected microscope with a large working distance (as appears in Applied Optics, Vol. 37, No. 10, , 1 April 1998)

Axial intensity distribution of lens axicon illuminated by Gaussian-Schell model beam

Physics 441/2: Transmission Electron Microscope

Diffraction and Young s Single Slit Experiment

Acoustic Terms, Definitions and General Information

Light Control and Efficacy using Light Guides and Diffusers

Fig.1. The DAWN spacecraft

One example: Michelson interferometer

Fundamentals of modern UV-visible spectroscopy. Presentation Materials

3D ACOUTIC SIMULATIONS FOR NONLINEAR ACOUTIC CONCEALED WEAPONS DETECTION

Copyright 2008 Pearson Education, Inc., publishing as Pearson Addison-Wesley.

Raman Spectroscopy Basics

Biomedical Optics Theory

Proposed experiment to test the non-locality hypothesis in transient light-interference phenomena

Fast Varifocal Lenses Based on KTa 1-x Nb x O 3 (KTN) Single Crystals

CREOL, College of Optics & Photonics, University of Central Florida

Scanning Acoustic Microscopy Training

Towards large dynamic range beam diagnostics and beam dynamics studies. Pavel Evtushenko

Antonio Rampoldi Struttura Complessa di Radiologia Interventistica Azienda Ospedale Niguarda Ca Granda, Milano. Terminology

Transcription:

Imaging ultrasound field and shear wave propagation using acoustooptic laser speckle contrast analysis (AO-LASCA) Lipei Song a,b, Yi Cheng c, Rui Li c, Meng-Xing Tang c, Daniel S. Elson a,b a Department of Surgery and Cancer, Imperial College London, United Kingdom b Hamlyn Centre for Robotic Surgery, Imperial College London, United Kingdom c Department of Bioengineering, Imperial College London, United Kingdom ABSTRACT In this paper we present a method to visualize the pressure field of an ultrasound beam in a single shot of the CCD and to image the shear wave propagation based on acousto-optic laser speckle contrast analysis. The contrast images show features in the near field, far field and central region of the ultrasound beam and the pressure profile fits with that measured with a hydrophone. The shear wave propagation was acquired by changing the imaging delay time after the ultrasound burst. This method can be used to study the shear wave properties of common tissue phantoms to guide experiments on tissue. Key words: Imaging ultrasound field, laser speckle contrast, single shot, shear wave propagation 1. INTRODUCTION The measurement of the pressure field of an ultrasound beam and the shear wave propagation is important for investigating the ultrasonic properties of the medium, which is highly desirable in disease diagnosis. The measurement of ultrasound beams is also important for understanding and controlling the properties of the ultrasound in real media. Currently hydrophones provide the gold standard method for measuring the ultrasonic field of the transducers, but this method is time consuming due to the requirement to scan the ultrasonic field, and additionally the medium needs to be fluid to allow the free positioning of the hydrophone [1]. The pressure of the ultrasonic changes the refractive index of the material and generates refractive index gratings. Schlieren systems have previously been used to visualise the ultrasound field using the diffraction effect when incident light passes through this grating. Schlieren systems have a high spatial resolution and are able to detect the ultrasound wave period in the media by using pulsed illumination and short camera integration times. However the requirement for a relatively static grating within the acquisition period demands short illumination and therefore low signal levels. Furthermore for imaging the whole ultrasonic field in the media, a series of individual images are acquired with different delay times according to the propagation speed of sound and then these images are stitched together [2]. Previously lock-in detection methods have also been proposed to detect the ultrasound wave in clear media, but this technique requires multiple images to be acquired with different phases between the ultrasound and illumination modulated light [3]. Shear wave propagation in tissue has been investigated for the purpose of diagnosis and disease identification [4-6]. The speed and intensity of shear waves vary depending on the mechanical and acoustic properties of the tissue, such as the tissue elasticity and the absorption coefficient of sound. These properties may be related to pathological changes. The most common method of detecting the shear wave propagation is to measure the time delay of the shear wave generated remotely with a focused ultrasound beam. Some researchers have tried detecting the shear wave propagation optically. by focussing a light beam onto an optically absorbing particle and detecting the light alternatively transmitted and blocked by the particle due to its shear wave-induced displacement [5]. Bossy et al. made use of the temporal decorrelation of the light passing through an ultrasound field to acquire a full field shear wave image and its propagation could be detected by using different delay times between the ultrasound and optical acquisition [7]. However this method requires a fast detector, operating at 2 khz, and a sequence of images are needed to calculate the decorrelation. A fast and full-field imaging method for the US pressure field and shear wave propagation can help to identify the location of the ultrasound field in US related experiments, to investigate the tissue elastic properties, which are related to the propagation speed of the shear wave, and may potentially assist the diagnosis for cancer and other diseases.

In this paper we present a method to visualize the pressure field of ultrasound beam and shear wave propagation with pseudo-colour based laser speckle contrast analysis (LASCA). It is a fast and full-field technique and the ultrasound field can be imaged in a single shot and its propagation recorded. The method is applicable not only in water but also solid or gel-like materials, such as agar with intralipid, a common tissue phantom. 2. METHODS When an ultrasound beam is applied to a medium, the particles in the medium are oscillating at the ultrasound frequency while being gradually displaced due to the acoustic radiation force. Once equilibrium is reached the particles only oscillate about that displaced position at the ultrasound frequency. If we ignore nonlinear effects, there are two waves propagating the media: one is the US beam which travels by the simple harmonic oscillation of the particles at the frequency of the ultrasound and the other is the shear wave that propagates perpendicular to the US beam. The generation and propagation of the shear wave depends on the US absorption of the media. When a laser beam passes through an optically scattering material, a speckle pattern is generated at the image plane due to the random interference of the arriving photons that have travelled through different path lengths. The ultrasound field influences this interference speckle pattern because the phase of the light passing through the ultrasound is modulated due to the acoustic radiance force and the ultrasound induced particle oscillation. The contrast found within the speckle pattern reflects the modulation depth and the speed of the motion, and can be used to detect properties of the ultrasound field [8, 9]. Since the average particle speed depends on the applied pressure, the contrast distribution indicates the pressure field of the ultrasound beam. If an optical image of the ultrasound field can be formed then the effects and spatial location of the ultrasound oscillation and shear wave can be distinguished, as described below. Figure 1. Experiment setup Two experiments were preformed: one to image the US field and the other to capture the propagation of the shear wave. The experimental setup is shown in Fig 1. A laser beam (Excelsior 532, Newport, Incorporated, U.S., 532 nm, 100 mw) was expanded using a lens and was incident on the phantom. The focused ultrasound beam (5 MHz, 1 mm and 10 mm lateral focal width and focal length respectively at 50 mm working distance) was aligned to pass through the output surface of the phantom and the output surface was imaged onto a CCD (QImaging, Fast Exi, cooled) using a lens (f=30 mm, Thorlabs). The phantom consisted of two layers: one was 2% Agar in water (the transparent layer to US) and the other had the same concentration of agar but was mixed with 10 % intralipid. For the first experiment the US field was applied on the layer with pure agar. This is because Agar lightly scatters the light, so it can generate a clear US beam shape. In the second experiment the phantom was reversed to locate the layer with agar and intralipid in the US field. This time the intralipid played the role of a US absorber to generate the shear wave [10]. A bandpass filter and a polarizer (B in Fig. 1) were added after the lens to eliminate the stray light and maintain the linear polarization

respectively. The speckle size was controlled to be equal to two CCD pixels by an aperture (A in Fig. 1) in front of the lens, thereby satisfying the Nyquist criterion. The FOV was 20 mm x 30 mm to record a large region of the ultrasound beam and the exposure time was set to 2 ms with a trigger system [8] used to control the delay time at which the CCD was exposed. A 7 by 7 moving window was used to calculate the contrast map of the speckle images and then the contrast difference map was derived by subtracting the contrast value of the speckle images captured at the different delay times from that of the initial contrast map when the US was off. The higher the contrast difference, the higher the pressure of the ultrasound. In the first experiment to image the US beam, the output surface contained only agar. 20 images were recorded both before and after ultrasound was applied. A delay time of 1 ms was used after the ultrasound was turned on so that the modulation reached a stable state before capturing the image. The contrast difference of the ultrasound pressure was averaged over 20 images to reduce the noise and a colour map was applied to illustrate the contrast difference. In the second experiment a US burst which lasted 2 ms was applied to the phantom. A series of speckle images were recorded after the ultrasound signal was turned on with a step size of 0.5 ms. One image was captured before and after the ultrasound was turned on for each delay time for calculating the contrast difference. 3. RESULTS The contrast difference image of the ultrasound field is shown in Fig 2 where the ultrasound propagation direction is from top to bottom. The shape of the focused ultrasound beam is clearly evident in Fig. 2 (a), and the focus, which was located in the middle of the image, can be identified not only by the shape of the beam but also by the higher contrast difference in this area. This implies that the particles have a higher average speed and displacement at the focus. The near field structure of the ultrasound can also be observed, especially when imaging at higher magnification as shown in Fig 2 (b). X Y (a) Figure 2: Contrast difference map. (a) the ultrasound beam and (b) the near field area. Spatial profiles of the contrast were calculated along the ultrasound axis by averaging the three central pixels in x direction at each y position. The result is shown in Fig 3 (a) alongside comparative data acquired with the hydrophone in water. The data sets are scaled to compare the profile shape only, and show good agreement except for some spikes in the experimental result. This same calculation was repeated for the x-direction in the range of -3 to +3 mm corresponding to the central point of the US focus and the result is shown in Fig 3 (b). Again there is a close match to the hydrophone data and the FWHM diameter of the ultrasound was calculated to be around 0.8 mm using both methods. Therefore there appears to be a relationship between the contrast difference and the ultrasound pressure, which could enable the retrieval of the pressure field simply by recording the contrast distribution. Fig. 4 demonstrates the propagation of the shear wave. Fig. 4(a) was acquired when the ultrasound had been on for 1 ms. Fig. 4(b) was captured 1 ms after the ultrasound was turned off. The ultrasound shape was still perceivable but less (b)

clear than in (a). Fig. 4(c) shows the contrast difference map after 2 ms delay. The shear wave propagated mainly in the x direction. And (d) shows more expanded shear wave field after 3 ms delay. The spread of the shear wave in the X direction was around 6 mm suggesting that the shear wave velocity was 2 mm/ms. Contrast difference [a.u.] 0.09 0.06 0.03 645 430 215 Pressure [mvpp] (a) 0-3 -2-1 0 1 2 3 0 Position in X direction (mm) (b) Figure 3. the profile of the ultrasound field in (a) Y direction and (b) X direction. (a) (b) (c) (d) Figure 4. Propagation of the shear wave. (a) the ultrasound is on; (b) to (d): 1ms, 2ms and 3ms delay after the ultrasound was turned off 4. DISCUSSION Acousto-optic laser speckle contrast analysis is a fast imaging method to measure the pressure field of the ultrasound. The pressure field is shown in a pseudo-colour image. The CCD exposure time needs to be adjusted to achieve the best image contrast. Otherwise the contrast value in the ultrasound area may be too close to the surrounding area and unperceivable. Here we chose 2 ms after some testing using shorter and longer exposure times. The experimental results showed that LASCA can capture the ultrasonic beam in a single shot, but loses the spatial resolution and the ultrasound wave period is not resolvable. This is because the ultrasound propagates more than one period during the CCD exposure time and the light field collected by the CCD is therefore an averaged modulation of multiple periods. The ultrasound beam has to be located at the output surface of the phantom otherwise the laser modulated by the shear wave will be scattered randomly and the spatial resolution reduced. 5. CONCLUSION

Based on the light modulation induced by the ultrasound, LASCA can capture both the pressure field of the focused ultrasound signal in a single shot and the propagation of the shear wave generated by the radiation force in a timelapse sequence of images. The contrast profile from the image fits well with the hydrophone data. By changing the delay time of the CCD exposure after turning off the ultrasound modulation, we can capture the propagation of the shear wave. The image noise can be deduced by the average over multiple contrast images acquired at the same delay time. REFERENCES [1] B. Schneider, and K. K. Shung, Quantitative analysis of pulsed ultrasonic beam patterns using a schlieren system, Ultrasonics, Ferroelectrics and Frequency Control, IEEE Transactions on, vol. 43, no. 6, pp. 1181 1186, (1996). [2] T. Neumann, and H. Ermert, Schlieren visualization of ultrasonic wave fields with high spatial resolution, Ultrasonics, vol. 44, pp. e1561 e1566, (2006). [3] G. Yao, Full field mapping of ultrasonic field by light source synchronized projection, The Journal of the Acoustical Society of America, vol. 106, no. 4, pp. L36, (1999). [4] J. L. Gennisson, S. Catheline, S. Chaffaï et al., Transient elastography in anisotropic medium: application to the measurement of slow and fast shear wave speeds in muscles, The Journal of the Acoustical Society of America, vol. 114, pp. 536, (2003). [5] A. P. Sarvazyan, O. V. Rudenko, S. D. Swanson et al., Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics, Ultrasound in medicine & biology, vol. 24, no. 9, pp. 1419 1435, (1998). [6] S. Chen, M. Fatemi, and J. F. Greenleaf, Quantifying elasticity and viscosity from measurement of shear wave speed dispersion, The Journal of the Acoustical Society of America, vol. 115, pp. 2781, (2004). [7] E. Bossy, A. R. Funke, K. Daoudi et al., Transient optoelastography in optically diffusive media, Applied physics letters, vol. 90, pp. 174111, (2007). [8] R. Li, L. Song, D. S. Elson et al., Parallel detection of amplitude modulated, ultrasound modulated optical signals, Opt. Lett., vol. 35, no. 15, pp. 2633 2635,(2010). [9] R. J. Zemp, C. Kim, and L. V. Wang, Ultrasound modulated optical tomography with intense acoustic bursts, Applied Optics, vol. 46, no. 10, pp. 1615 1623,( 2007). [10] N. Parmar, and M. C. Kolios, An investigation of the use of transmission ultrasound to measure acoustic attenuation changes in thermal therapy, Medical and Biological Engineering and Computing, vol. 44, no. 7, pp. 583 591, (2006).