How can a charging station for electric vehicles be set up simply and safely?



Similar documents
5SV Residual Current Protective Devices

Residual Current Protective Devices

The complete range of consumer switchboards and switchgear

SURGE PROTECTIVE DEVICES

R.C.C.B. s two-pole LEXIC

W DATA SHEET: RESIDUAL CURRENT CIRCUIT BREAKER A, SERIES BCF0 AND BCF6

Circuit Breakers. Next Generation of Protection Capabilities

USER MANUAL CHARGING STATIONS FOR ELECTRIC VEHICLES

Certificate of Compliance

Electronic overload relay EF19 and EF45

Technical data. RCBO s DS 261 / DS 271 Residual current operated circuit breakers with integral overcurrent protection

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

3RT1015-1BB41 CONTACTOR, AC-3 3 KW/400 V,

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

BETA Switching. Switching Devices. 5TT5 8 Insta contactors, AC technology. Overview

Notes on Product Changeover

SELECTION OF FINAL CIRCUIT PROTECTION

Electric Vehicle Charging Solutions

Remote Monitoring and REC 501 Control Unit Product Guide

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Electronic overload relay EF65, EF96 and EF146

What ensures easy and fast wiring?

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Electric Vehicle Charging Station Products EVoReel Charge Cable Management Solutions

SENTRON Switching and Protection Devices Air Circuit Breakers

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

JUNE emobility. Charging Stations DOWNLOAD DATA SHEETS AND TENDER TEXTS. for charging stations emh1 here:

Charge Controller CC611/CC612 Preliminary datasheet

Switching Devices Contactors and Contactor Assemblies Special Applications

CHARGING STATIONS FOR ELECTRIC VEHICLES QUICK CHARGER

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Maximum Demand Control

Safety technique. Emergency stop module BO 5988 safemaster

Quick Connect. quick - simple - efficient.

Controls Solid-State Switching Devices

Digital input modules

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Product Information DBT-CEV CHARGING SOLUTIONS FOR ELECTRIC VEHICLES CATALOGUE

AF / AF09Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

E-STOP relays, safety gate monitors

TX OPEN RS232/485 module

Thyristor-controlled power supplies and battery chargers

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Fundamentals of Power

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

D-Line Contactors, Overload Relays and Accessories

SITOP power supply. Technical data. SITOP Power Supply. Answers for industry.

J TB/TW Temperature limiter, temperature monitor

CONFIGURABLE SAFETY RELAYS

PSR The compact range Description

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

MOTOR PROTECTIVE DEVICES

49 Series - Relay interface modules A. Features

QUICK REFERENCE PRICE GUIDE JULY 2015

Switching Devices. 8/2 Introduction. 8/5 5TE8 control switches. 8/8 5TE4 pushbuttons. 8/11 5TE5 light indicators. 8/13 5TE On/Off switches

HERZ-Thermal Actuators

Relés e Contatores de Estado Sólido SIRIUS

Digital display DA 48

ASSEMBLED SOCKET-COMBINATIONS

Three-phase monitoring relay CM-PFE

Figure 1 - Crydom 3RHP Three-phase Hybrid Solid State Contactor. Crydom Inc.

The power distribution board that sets new standards

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Mini Motor Contactor J7KNA Main contactor Accessories Approved Standards Standard Guide No (US,C) Ordering Information tage Model Number Legend gear

ABB solutions for photovoltaics Protection and other modular devices

48 SERIES Relay interface modules 10 A

38 Series - Relay interface modules A

PCS0100en Persy Control Services B.V. Netherlands

MasterINTERFACE 39 Series - Relay interface modules

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Catalog. Modular DIN rail components Installation contactors

SYSTEM MONITORING Locally and remotely

Intersection Preassembled 19-inch Rack

Installation Contactors. Technical Catalogue. Type ESB. abb. ABB STOTZ-KONTAKT GmbH 1 2CDC C0201

Residual Current Circuit Breaker

Products and solutions for pumping, irrigation and piping

3-phase, bidirectional energy meter

CONFIGURABLE SAFETY RELAYS

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

ISIO 200. Binary Input/Output (I/O) Terminal with IEC Interface

ABB 1. Three-phase monitoring relay CM-PFS. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories. Application.

Bimetallic Overload Relay Specifications

Our brand POWER DYNAMIC PASSION COMMITMENT CREATIVITY. A strong brand for strong products: 8PU Premium. MV Energy

38 Series - Relay interface modules A

A project to optimise quality and energy efficiency must include metering

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Guide to the China Compulsory Certification System December 2009 OMRON Corporation Industrial Automation Company

Product Guide. Low voltage grounding system. Answers for industry.

Product and functional description

ISL Insulation monitoring devices Continuous monitoring of IT systems from photovoltaic to industrial applications.

Electrical safety and protection devices

Features. Display. Measurements. Intelligent. Accuracy. Models. Installation DEIF A/S. Multi-instrument D

Number 1 in efficiency

C E R T I F I C A T E O F C O M P L I A N C E

NF71E-.. / NFZ71E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Transcription:

SB18 Building > Electromobility > Charging Station Design How can a charging station for electric vehicles be set up simply and safely? Requirement In order to supply electric vehicles with electric power, charging stations and car parks must be equipped with charging points. This means combining different functionalities with attractive design. The right low-voltage energy distribution components must be used to suit the prevailing charging power, environmental conditions and location. Pre-defined solution packages are expected here to be scaled in functionality and performance class. The charging stations must comply with the applicable standards and connection conditions, such as IEC 61851. Reliable electromobility Charging an electric vehicle www.siemens.com/ee-applications

Our answer: Standard-compliant protection, switching and measuring equipment for scalable solutions Siemens offers the right protection, switching and measuring equipment for installing in charging stations. The products meet the requirements regarding short-circuit protection, climatic environmental conditions, system configuration and safety engineering. 1 Monitoring device 7KT PAC1500 3 5SM3 residual current circuit breaker Branch option A 4A Miniature circuit breaker 5SY4 5A Insta contactor 5TT5 Charging socket 6 Charging controller 6 Charging controller 2 Surge arrester 5SD7, type 2 Branch option B 4B SIRIUS circuit breaker 5B Power contactor Branch option A contains a miniature circuit breaker and an Insta contactor, Branch option B contains a circuit breaker and a power contactor from the SIRIUS product range. Highlights Comprehensive portfolio for maximum safety Control modules for charging interfaces Field-proven, high-quality protection, switching, measuring and monitoring equipment Wide range of circuit breakers and miniature circuit breakers with accessories such as remote drive and auxiliary circuit switches Universal-current-sensitive residual-current circuit breakers (RCCBs) type B (SIQUENCE) Monitoring device 7KT PAC1500 with communication interface Standard compliance The products meet configuration functionality requirements for electric vehicle charging stations in accordance with IEC 61851 and IEC 60364 Customer-friendly design Simple installation and wiring since all components are suitable for DIN rail mounting

Siemens offers products for charging stations matched according to rated performance classes: Example of single-phase charging station, 230 V, 3 kw Charging controller 230 V supplied, for changing interfaces 16 A, 230 V Alternative: charging controller 24 V supplied, for charging unit 16 A, Alternative: charging controller with Ethernet interface stand-alone 24 V supplied, for charging unit 6 80 A 5TT3 200-2KK20 5TT3 200-2KK30 Surge arrester, type 2, 350 V AC (with remote signaling) 5SD7 461-1 RCCB, type B, 30 ma, 25 A recommended (or RCCB, type A super resistant K, 30 ma, 25 A) 5SM3 322-4 (5SM3 312-6KK01) MCB, 16 A, 1+N, C char., 10 ka 5SY4 516-7 Insta contactor, 2 NO contacts, 20 A 5TT5 800-0 Optional: Measuring device 7KT PAC1500 7KT1 530 Enclosure (e.g. ALPHA SIMBOX WP 280 x 410 x 140 mm) 8GB1 371-3 Example of single-phase charging station, 230 V, 7 kw Charging controller for charging unit 32 A, Surge arrester, type 2, AC 350 V (with remote signaling) Alternative: charging controller with Ethernet interface stand-alone 24 V supplied, for charging unit 6 80 A RCCB, type B, 30 ma, 40 A recommended (or RCCB, type A super resistant K, 30 ma, 40 A) 5TT3 20-4KK20 5SD7 461-1 5SM3 324-4 (5SM3 314-6KK01) MCB, 32 A, 1+N, C char., 10 ka 5SY4 532-7 Optional: Measuring device 7KT PAC1500 7KT1 530 Enclosure (e.g. ALPHA SIMBOX WP 280 x 410 x 140 mm) 8GB1 371-3 Example of 3-phase charging station, 400 V, 11 kw Charging controller 230 V supplied, for charging unit 16 A, Alternative: charging controller 24 V supplied, for charging unit 16 A, Alternative: charging controller with Ethernet interface stand-alone 24 V supplied, for charging unit 6...80 A TT3 200-2KK20 5TT3 200-2KK30 Surge arrester, type 2, AC 350 V (with remote signaling) 5SD7 464-1 RCCB, type B, 30 ma, 25 A recommended (or RCCB, type A super resistant K, 30 ma, 25 A) 5SM3 342-4 (5SM3 342-6KK01) Branch option A Miniature circuit breaker, 16 A, 3+N, C char., 10 ka 5SY4 616-7 Branch option B SIRIUS circuit breaker 11...16 A, 3-pole, 55 ka 3RV20 21-4AA10-0DA0 SIRIUS power contactor, 4-pole, 18 A (AC-1), coil AC 230 V, 50/60 Hz 3RT23 16-1AP00 Optional: Measuring device 7KT PAC1500 7KT1 543 Enclosure (e.g. ALPHA SIMBOX WP 463 x 410 x 140 mm) 8GB1 372-3 Example of 3-phase charging station, 400 V, 22 kw Charging controller for charging unit 32 A, Surge arrester, type 2, AC 350 V (with remote signaling) Alternative: charging controller with Ethernet interface stand-alone 24 V supplied, for charging unit 6 80 A RCCB, type B, 30 ma, 40 A recommended (or RCCB, type A super resistant K, 30 ma, 40 A) 5TT3 200-4KK20 5SD7 464-1 5SM3 344-4 (5SM3 344-6KK01) Branch option A MCB, 32 A, 3+N, C char., 10 ka 5SY4 632-7 Optional: according to charging mode: miniature circuit breaker, 16 A, 3+N, C char., 10 ka 5SY4 616-7 Branch option B SIRIUS circuit breaker 27...32 A, 3-pole, 55 ka 3RV20 21-4EA10-0DA0 SIRIUS power contactor, 4-pole, 40 A (AC-1), coil AC 230 V, 50 Hz, integral auxiliary contacts 1 NO contact + 1 NC contact 3RT23 26-1AP00 Optional: according to charging mode*: SIRIUS circuit breaker, 11...16 A, 3-pole, 55 ka Optional: according to charging mode*: SIRIUS power contactor, 4-pole, 18 A (AC-1), coil AC 230 V, 50/60 Hz 3RV20 21-4AA10-0DA0 3RT23 16-1AP00 Optional: Measuring device 7KT PAC1500 7KT1 543 Enclosure (e.g. ALPHA SIMBOX WP 463 x 410 x 140 mm) 8GB1 372-3

Example of 3-phase charging station, 400 V, 43 kw Surge arrester, type 2, AC 350 V (with remote signaling) Charging controller with Ethernet interface stand-alone 24 V supplied, for charging unit 6 80 A 5SD7 464-1 RCCB, type B, 30 ma, 80 A recommended (or RCCB, type A super resistant K, 30 ma, 80 A) 5SM347-4 (5SM3 347-6KK01) Branch option A MCB, 63 A, 3+N, C char., 10 ka 5SY4 663-7 Optional: according to charging mode: miniature circuit breaker, 16 A, 3+N, C char., 10 ka 5SY4 616-7 Optional: according to charging mode: miniature circuit breaker, 32 A, 3+N, C char., 10 ka 5SY4 632-7 Branch option B SIRIUS circuit breaker 45...63 A, 3-pole, 55 ka 3RV10 41-4JA10-0DA0 SIRIUS power contactor, 4-pole, 100 A (AC-1), coil AC 230 V, 50 Hz 3RT13 44-1AP00 Optional: according to charging mode*: SIRIUS circuit breaker 11...16 A, 3-pole, 55 ka 3RV20 21-4AA10-0DA0 Optional: according to charging mode*: SIRIUS power contactor, 4-pole, 40 A (AC-1), coil AC 230 V, 50 Hz, integral auxiliary contacts 1 NO contact + 1 NC contact 3RT23 26-1AP00 Optional: according to charging mode*: SIRIUS circuit breaker 27...32 A, 3-pole, 55 ka Optional: according to charging mode*: SIRIUS power contactor, 4-pole, 18 A (AC-1), coil AC 230 V, 50/60 Hz 3RV20 21-4EA10-0DA0 3RT23 16-1AP00 Optional: Measuring device 7KT PAC1500 7KT1 543 Enclosure (e.g. ALPHA SIMBOX WP 463 x 410 x 140 mm) 8GB1 372-3 Accessories Auxiliary circuit switch, 1 NO contact + 1 NC contact (RCCB) 5SW3 300 Remote drive (RCCB) 5ST3 051 Auxiliary circuit switch, 1 NO contact + 1 NC contact (miniature circuit breaker) 5ST3 010 Remote drive (miniature circuit breaker) 5ST3 050 Auxiliary circuit switch, 1 NO contact + 1 NC contact (Insta contactor) 5TT5 910-1 Auxiliary switch with mirror contacts (1 NO contact + 1 NC contact) for SIRIUS power contactor (charging station 16 A, 32 A) 3RH29 11-1HA11 Auxiliary switch (1 NO contact + 1 NC contact) for SIRIUS power contactor (charging station 16 A, 32 A) 3RH19 21-1CA10 Link module circuit breaker/sirius power contactor (charging station 16 A) 3RA19 21-1DA00 Auxiliary switch (1 NO contact + 1 NC contact) for SIRIUS circuit breaker (charging station 63 A) 3RV29 01-1E Signaling switch for tripping method for SIRIUS circuit breaker (charging station 16 A, 32 A) 3RV29 21-1M Signaling switch for tripping method for SIRIUS circuit breaker (charging station 63 A) 3RV19 21-1M When used with remote drive, cost savings with 2-in-1 device (RCBO) RCBO, type A, 30 ma, 16 A, C char., 1P+N, 10 ka 5SU1 354-7KK16 RCBO, type A, 30 ma, 32 A, C char., 1P+N, 10 ka 5SU1 354-7KK32 Remote drive (RCBO) 5ST3 050 Subsystems Fully configured, pre-assembled and tested subsystems can also be supplied for setting up charging stations based on the above sample combinations of individual products. 6FE1086* on request * Charging modes in accordance with IEC 61851. Please observe the applicable regulations and environmental conditions, such as humidity, temperature, etc.

Main components required Product Description of functions 1 Measuring device 7KT PAC1500 7KT1 5 Digital electric meters record the active and reactive energy with high accuracy. They are available in calibrated versions in accordance with the new measuring instruments directive 2004/22/EC (MID). They can thus also be used for billing of the energy drawn. 2 Surge arrester 5SD7, type 2 5SD7 4 Lightning conductors and surge arresters protect the charging infrastructure and the electric vehicle against overvoltages and surge currents. Failure of a device can be reported via remote signaling. 3 Residual current circuit breaker 5SM3 5SM3 Residual current circuit breakers are used for personnel and property protection, protection against fire and additional protection in the event of direct contact. A universal current-sensitive residual current circuit breaker Type B (SIQUENCE) is recommended for the charging station. In addition to AC and pulsing DC residual currents, it also detects smooth DC residual currents and thus secures the desired protection function in case of all residual current types. 4A Miniature circuit breaker 5SY4, 10 ka 5SY4 Miniature circuit breakers offer reliable protection against overload and short circuit. They can be supplemented with additional components and can thus also be integrated into a control system to allow the operating status of the charging station to be detected. 4B 5A SIRIUS circuit breakers 27...32 A, 3-pole, 55 ka 3RV20 21-4EA10-0DA0 Insta contactor 5TT5 5TT5 8 SIRIUS circuit breakers offer reliable protection against overload and short circuit, even in case of ambient temperatures up to 70 C (up to 60 C without derating). The devices enable low-cost and fault-proof installation and are also optionally available with spring-loaded terminals and connection module for the circuit breaker and contactor. In addition, versions with overload relay function are available, making mechanical restarting superfluous after an overload trip. Auxiliary and signaling switches, available as accessories, communicate the current switching status as well as the tripping method. Insta contactors switch the voltage supply on and off at the charging sockets. They are switched by the charging station controller. 5B SIRIUS power contactor 4-pole, 40 A (AC-1) integrated auxiliary contacts 1 NO + 1 NC contact 3RT23 26-1AP00 SIRIUS power contactors switch the power supply of the charging sockets on and off, with a long life span and at ambient temperatures up to 70 C (60 C without derating). The auxiliary contacts available as accessories are designed as mirror contacts in accordance with IEC EN60947-4-1. This meets the requirements for safety technology in personnel protection. Basic devices and accessories are optionally available with springloaded terminals. 6 SIPLUS ECC1000 CM-100 5TT3 2 The charging controller enables charging in in accordance with the IEC standard. It communicates with the electric vehicle, identifies the charging cable, and controls and monitors the switching devices and the plug interlock. The charging controller thus ensures maximum safety for the charging operation. Communication between the charging column and the electric vehicle by means of a pulse-width modulated signal.

Main components required Product Description of functions 6 SIPLUS ECC2000 CM-230 CM-230 standalone Optional. In addition to the functions of the charging controller CM-100 the CM-230 has an integrated Ethernet interface which makes communication with an intelligent load management possible. 6FE1021-3CM10-1AA0 CM-230 managed Further information For details on individual products: www.siemens.com/lowvoltage www.siemens.com/sirius For technical assistance regarding the use of products: www.siemens.com/lowvoltage/technical-support www.siemens.com/automation/support-request Siemens AG Industry Sector P.O. Box 48 48 90026 NUREMBERG GERMANY Subject to change without prior notice 10/11 Order No. E20001-A1060-M102-X-7600 Printed in Germany Siemens AG 2011 The information provided in this brochure contains merely general descriptions or characteristics of performance which in actual case of use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. www.siemens.com/ee-applications All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.