DETAILED DRAWINGS. Batten Fixing. Internal Wall Lining. Min. Rebate Depth as per NCC. Reinforced Concrete Slab. Nasahi Approved Coating.

Similar documents
NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Linea Weatherboard DIRECT FIX CONCRETE SLAB AND SOFFIT FIGURE 1

Fig. 2 WALL-TO-WALL PANEL CONNECTIONS CORNER WALL CONNECTION

The WANZ Guide to Window Installation

Superform Products Ltd.

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

SG Series 65mm Frame Windows (Fixed Lite Window Illustrated)

!!!!!! !!! Decra Plus DPSW010 DPSTW011 DPSW012 DPSW013 DPSW014 DPSW015 DPSW016 DPSW020 DPSW021 DPSW024 DPSW030 DPSW031 DPSW035 DPSW030 DPSW031 DPSW035

Contents. APA Construction Details. Full fill cavity walls Partial fill cavity walls Solid externally insulated walls 26-37

Melbourne balcony Assessments

The WANZ Guide to Window Installation

STEEL BUILDINGS RECOMMENDED INSTALLATION GUIDE

INSTALLATION OF A BAY WINDOW

Residential Inspection Guidelines

300mm. 2mm MIN GAP. PLACE 100mm X 100mm. SO THAT IT IS 38mm INTO

TECHNICAL MANUAL. airlite.com.au

COMMONLY USED RESIDENTIAL BUILDING CODES

KAHU RESIDENTIAL ROOFING RRKA DETAIL LIST

Installation Window Building In Details

FLAT ROOF BOX SPAN CARPORTS

Wet Area Construction. Carpentry - Residential Construction. Product Code: 5603

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

Leaky Homes Financial Assistance Package (FAP) Repair plan example

The formation of roof waterproofing details calls for

CARPENTRY - HOUSING. This is the sloping length of a right-angled triangle.

FLAT ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

BUILD A CARPORT. 2 - Planning the carport. 3 - Designing the carport

How To Build A Gambrel Roof And A Gable End Roof

Instruction Manual 19/9/01. Flat Roof Carport

The better way to build TM. Installation Manual. FOUNDATION SIPs & FROST WALLS SIPs

EDW + FS, VS, VSE, GGL, GGU, GHL. EDW Deck Mounted Skylight and Roof Window Flashing Installation Instructions VAS

HORIZONTAL INSTALLATION

Good Craftsmanship Guide. Carpentry and Joinery- Carcassing

PB301 July Lightweight Building Solutions. Bushfire Protection.

TIMBER FRAME STANDARD DETAILS SEPTEMBER 09

Mark Cramer Inspection Services, Inc.

HfHMD uses LP SmartSide siding and trim.

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: Purpose

K. D. FRAME ASSEMBLY FOR CLOSED STEEL STUD WALLS...Ins 10. FRAME INSTALLATION DETAILS FOR CLOSED STEEL STUD WALLS...Ins 11

rationel WINDOWS WITH VISION

Energy Company Obligation (ECO): Technical Monitoring Questions

House building is changing fast NHBC unveils new Standards Chapters on curtain walling and cladding, and light steel framed walls and floors

GYPROCK PARTY WALL INTERTENANCY WALL SYSTEMS FOR CLASS 1 BUILDINGS

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

Wisconsin Building Products Evaluation

EXAMPLE BILL OF MATERIALS

Ubiflex. Non-lead flashing system

Sun Windows General Information Sun New Construction Window Installation Instructions

March 14, Installation of Bay, Bow and Garden Windows

Additions and Alterations

Module 3.7. Thermal bridging

Free 12 x 8 Shed Plan With Illustrations, Blueprints & Step By Step Details

Residential Decks. Planning and Development Services Department

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

Window Installation Instructions

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Custom 30 x 20-8 Garage Plan Plan #g233 By SDS-CAD Specialized Design Systems

UBBINK SOLAR IN-ROOF SYSTEM

INSTRUCTIONS: LocknCharge Laptop Carts

2.1. Architectural Character. Mountain. Agrarian. Craftsman. Gold Rush

4 5/16 Subframe Installation

KITCHENS. Tip PAGE 1 FITTING YOUR KITCHEN GUIDE. How to mark out a kitchen. Tools required for installing a kitchen STEP ONE STEP TWO STEP THREE

H-Stud Area Separation Wall System

MUNICODE SERVICES LTD.

4. ANCHOR BOLTS AND STRAPS a. ½" anchor bolts shall be embedded 7" into concrete a maximum of 6' on center and 12" from corners and ends of plates.

IMPORTANT INSTALLATION GUIDE VALENCIA SQUARE CORNER SHOWER READ ALL INSTRUCTIONS CAREFULLY BEFORE STARTING THE INSTALLATION

STANDARD OPEN PATIO COVER

IRISH BUILDING CONTROL INSTITUTE HOTEL COURT HOTEL BALLYCONNELL CO CAVAN. 26 th MARCH 2009 TIMBER FRAME CONSTRUCTION

The minimum reinforcement for the stem wall is the placement of:

If stepping is required, step at 180mm as seen in this picture.

PANELIZED HOME INSTALLATION GUIDELINE

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

How To Repair A Boat Landing Deck With A Boat Bed

RESIDENTIAL FOUNDATION GUIDELINE Johnson County, KS

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

CONSTRUCTION DETAILS & LOAD DESIGN CHARTS

TYPICAL PATIO COVERS 111

AA Solar and Sun Power Plus

We urge you to read and follow the attached installation instructions. Failure to do so may void the warranty of this garden window unit.

Chapter 3 Pre-Installation, Foundations and Piers

Sliding and Folding Door Fittings Sliding Door Accessories

Repairing storm damaged roofs

Installation Guide. Bath and Wall Surrounds SERIES B

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

TFL CUSTOM FIREPLACES WITH MASONRY BRICK LININGS. standard INSTALLATION SPECIFICATION INTO TIMBER FRAMING

The better way to build TM. Installation Manual. EXTERIOR WALL SIPs

609 West Rock Road, Radford,VA / (fax) RECOMMENDED ATTACHMENTS & CONNECTION DETAILS

LAYING BLOCK AND BRICK

Is Your Envelope Effective? Mark Lawton P.Eng Morrison Hershfield Limited Vancouver

Envelope INSULATION BATT (2) Avoid Using Batt Insulation With Metal Framing. Pressure or Friction Fit

Clad Direct Glaze Window Installation Instructions

ENERGY STAR Qualified New Homes Thermal Enclosure Checklist. Water Management Checklist. Eli Caudill

Installation Instructions For Slider Casement Air Conditioners

UNIVERSAL ASSEMBLY INSTRUCTIONS FOR VERSATUBE BUILDINGS CONTRACTOR SERIES 2 X 4 FRAMES

Residential Roofing Guide

Installation Instructions and Ordering Information

PERIMETER FLASHING. Table of Contents

HURRICANE MITIGATION RETROFITS FOR EXISTING SITE-BUILT SINGLE FAMILY RESIDENTIAL STRUCTURES

Transcription:

DPC 2-3mm Gap F.G.L Max. Panel Overhang 250mm Min. Rebate Depth as per NCC Reinforced Concrete Slab Slab Edge Detail (Rebate) 20mm Min. DPC FGL Cavity Closer Strip Slab Edge Detail (Overhanging) Cavity Closer Strip DPC Masonry Bolts (ø8mm Zinc Plated) FGL 20mm Min. Slab Edge Detail (Overhanging Deepened Edge Beam)

DETAILED DRAWINGS Stepdown as per NCC Engineered Floor Joists Cement Sheet Caulking Skirting Tile (Optional) Screed (Slope as per NCC) Waterproof Membrane Paving Tiles Cement Sheet DETAIL 1.4 - Balcony Detail (Timber Frame) (Min. height 150mm) Skirting Tile (Optional) Stepdown as per NCC Screed (Slope as per NCC) Paving Tiles Waterproofing Membrane DETAIL 1.5 - Balcony Detail (Concrete Slab)

100mm Bugle Head Fixing @ 600mm Ctrs DETAIL 2.1 - External Corner Detail 5-10mm Extra Stud Expansion Joint DETAIL 2.2 - Internal Corner Detail *NOTE: Internal corners require an extra stud for panel attachment 150mm back from the internal corner.

Window DETAIL 3.1 - Window Head Window Window DETAIL 3.2 - Window Jamb Rubber Seal (By Window Manufacturer) 10mm Min. Min. 15º Fall Optional Decorative Trim DETAIL 3.3 - Window Sill (Decorative Trim) Window Rubber Seal (By Window Manufacturer) 10mm Min. Min. 15º Fall DETAIL 3.4 - Window Sill

DETAIL 4.1 - Flush Eave Quad Trim (Optional) DETAIL 4.2 - Eave Detail (Panel Under) Quad Trim (Optional) DETAIL 4.3 - Eave Detail (Panel Flush With Lining)

Z (Behind ) 5-10mm Gap DETAIL 5.1 - Cladding To Brick Detail Roof Tiles 10mm Min. Cavity Closer Strip (Behind ) DETAIL 5.2 - Panel to Angle Roof Detail (Up to 25º) Roofing 35mm Min. Cavity Closer Strip Roof Structure DETAIL 5.3 - Panel to Flat Roof Detail

(Control Joint) DETAIL 6.1 - Inter Floor Junction (Panel Joint in Joist Zone) Engineered Floor Joists ( Note: For engineered floor joists, shrinkage panel gap of 5-10mm is acceptable. For non-engineered floor joists, panel gap of 15-20mm is required Inter Floor Joist Zone Inter Floor Joist Zone Engineered Floor Joists Note: To avoid control joint the joist must close within 600mm panel Inter Floor Joist Zone DETAIL 6.2 - Inter Floor Junction (No Panel Joint in Joist Zone) Meter Box Panel to Panel 100mm Bugle Head Fixing @ 600mm Centres DETAIL 7.1 - Meter Box Installation DETAIL 8.1 - Column Detail

Min. 10mm Parapet Capping (By Others) Cavity Closer Strip Metal Roofing Fixing Roof Batten DETAIL 9.1 - Parapet Detail Panel Gap* 5-10mm DETAIL 10.1 - Expansion Joint (Horizontal) *NOTE: Panel gap can be between 5-8mm for an engineered joist frame (shrinkage less than 1%), for non-seasoned joists check with frame manufacturer, or provide 15-20mm. DETAIL 10.2 - Expansion Joint (Vertical) Light Duty Fixing Anchor Rainwater Downpipe Bracket Fixing DETAIL 11.1 - External Fixings to Wall

16mm Batten To Every Stud (Max 600mm Crs) To Be Used Where External Access To Wall Is Available DETAIL 12.1 - Standard External Wall Detail Existing Building 20mm Or 50mm Depending On Boundary Wall Installation Method (Stand Up Frame Or Slide In Panels) (45mm Hex Head Screws) Top Hat Top Hat Fixing (1 leg fixed @ 600mm crs the second leg fixed to top plate, noggins and bottom plates) To Be Used Where External Access To Wall Is Not Available DETAIL 12.2 - Boundary Wall Fixing Detail A Existing Building 20mm Or 50mm Depending On Boundary Wall Installation Method (Stand Up Frame Or Slide In Panels) Batten Clip To Top Plate, Noggings & Bottom Plate (Max 600mm Crs) To Be Used Where External Access To Wall Is Not Available DETAIL 12.3 - Boundary Wall Fixing Detail B

min. 50mm min. 50mm Capping over Boundary Wall Cavity Existing Dwelling Capping over Boundary Wall Cavity Roof Detail as per NCC Roof Detail as per NCC Existing Dwelling Metal Tophat Metal Tophat Tophat fixing Tophat fixing DPC 150 step down 2-3mm Gap DPC 150 step down 2-3mm Gap min. 70mm DETAIL 13.1 - Boundary Wall Detail (Even Slab) min. 70mm DETAIL 13.2 - Boundary Wall Detail (Uneven Slabs)

min. 20mm min. 20mm Capping over Boundary Wall Cavity (Required) Existing Dwelling Capping over Boundary Wall Cavity (Required) Roof Detail as per NCC Metal Tophat Roof Detail as per NCC Metal Tophat Existing Dwelling Tophat fixing Tophat fixing DETAIL 13.3 - Boundary Wall Detail (Even Slab, Without Slab Rebate) DETAIL 13.4 - Boundary Wall Detail (Uneven Slabs, Without Slab Rebate)