VisionPRO Series with RedLINK. Installation Guide

Similar documents
Installation Guide. Prestige IAQ with Equipment Interface Module. RedLINK to Equipment Interface Module. RedLINK to TrueZONE Wireless Adapter

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

VisionPRO 8000 with RedLINK

Installation Guide. LR-HWLV-HVAC TouchPRO Wireless. System Types

Installation Guide. Programmable Thermostat TH6220D

RedLINK Wireless Comfort Systems. RedLINK Connects.

Wireless and Prestige Comfort Systems. Frequently Asked Questions Guide

Alerts and Delta T Diagnostics with the Prestige 2.0 IAQ Thermostat

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Operating Manual. Prestige THX9000 Touch-screen Thermostat Thermostat à écran tactile Termostato con pantalla táctil

Professional Contractor INSTALLATION GUIDE

CONTROLS KITS AND ACCESSORIES /2014 Supersedes10/2014

Wireless Solutions. Application Selection Guide

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Installation Instructions

Installer Guide smart connect

UV100A Ultraviolet Air Treatment System

Install Guide CT101. Caution. Caution

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT

Communicating Wall Control Installation Manual TSTAT0101SC

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

HEAT PUMP PROGRAMMABLE THERMOSTAT

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

User Manual THR840DUK Digital Thermostat

COMFORT CONTROL - 4 HEAT (GAS, OIL*, OR ELECTRIC)/3 COOL/HEAT PUMP COMMUNICATING PROGRAMMABLE 3 WIRE HOOKUP

APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!

Drayton Digistat +2RF/+3RF

INSTALLATION INSTRUCTIONS

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

How To Control A Thermostat

HMI display Installation Guide

Technical support is also available by or by phone: (North America) (International)

T7079A,B Solid State Remote Temperature Controllers

Install Guide CT100. Caution. Caution ENGLISH. disconnect the power supply before beginning work.

Table of Contents. 1 - Specifications Installation Wiring User controls...7

QUICK INSTALLATION GUIDE

Data logger. Installation and operating instructions. Read carefully before installation, commissioning and operation.

Install Guide 3M-50. Caution. Caution

HP Port Switches Quick Setup Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

THX9321 Prestige 2.0 THX9421 Prestige IAQ 2.0 with EIM

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

T-100-R Installation Guide

WHITE-RODGERS COMFORT-SET 90 SERIES

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Portable Air Conditioner

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

VIVA 4G LTE Mini Router. Quick Start Guide

HEAT HEAT COOL HEAT PUMP COOL

Quick Start Guide. WRV210 Wireless-G VPN Router with RangeBooster. Cisco Small Business

HP ProDisplay P19A LED Backlit Monitor. User Guide

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss Heating Solutions

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

The THERMOSTAT THE EVOLUTION OF CAPABILITIES INTO A PLATFORM FOR ENERGY MANAGEMENT

Windows 10.1 Tablet (UB-15MS10 and UB-15MS10SA) FAQ December 2014

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Wireless Indoor/ Outdoor Thermometer

Energy Communication Unit (ECU)

Safety & Installation Instructions

Nest Learning Thermostat Pro installation & configuration guide

Installation Instructions

Quick Start Guide. RV0xx Series Routers

SPL 2-00/-01 OPERATION INSTRUCTIONS

FIREDEX Conventional Fire Panels

ADSL Modem Installation Guide. Model # 36R515 Part # Rev. D Revision Date 12/2000. ADSL Modem Installation Guide

HP ProDisplay P17A LED Backlit Monitor. User Guide

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

Back-UPS Pro 1300/1500 Installation and Operation

Rock-Ola Music Center Set-Up and Installation Guide For all Q-Series models 230V, Export

Energy Communication Unit (ECU)

WPR400 Wireless Portable Reader

ComfortLink II Installation Guide. 3 Zone Panel (optional) 4 Zone Sensor with Display (optional) 5 Zone Sensor (optional) 6 Zone Dampers (optional)

Wireless 7 Day Programmable Room Thermostat

Powerline 1200 User Manual

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Quick Start Guide. RV 120W Wireless-N VPN Firewall. Cisco Small Business

User Guide. Linksys PLWK400. Powerline AV Wireless Network Extender Kit

INSTALLER S & OWNER S MANUAL

Alpha Climatic Programmable Modulating Boiler Energy Manager. Installation and User Instructions

CT3200 Programmable Thermostat

Lenovo IdeaPad. User Guide. Read the safety notices and important tips in the included manuals before using your computer.

=============================== WARNING

User Guide ecobee ecobee 250 University Ave Suite 400 Toronto Ontario M5H 3E5 Canada Toll free

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

UP400 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

Installation and Operation Back-UPS 1250, 1300, 1500

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

CW-5000/ 5200,1'8675,$/ &+,//(5 86(5 0$18$/

BLU Vivo 4.3 User Manual

ETHERNET IRRIGATION CONTROLLER. Irrigation Caddy Model: ICEthS1. User Manual and Installation Instructions

Transcription:

VisionPRO Series with RedLINK Installation Guide

Reference to key features * Password is the date code. Current display. Underlined label signifies the current display. Mode control buttons. Use to change settings for Fan or System Heat/Cool. Menu. Select options to: set schedules, view equipment status, change IAQ settings, access installer options*, etc. Current status. Shows system mode (heat/cool), outdoor temperature and humidity (with optional outdoor sensor). Current schedule. Shows desired temperature and schedule status. Indoor conditions. Shows indoor temperature and humidity. Current Time. Alert Light. On when alert message is active or system is set to Em Heat. Flashes for battery-only power; on continuous for 24 VAC. microsd Card Port. Use card to load settings and dealer information. Getting started Follow these basic steps to install this thermostat, link it with the wireless accessories, and set installer options. 1 2 3 4 Installing the thermostat Powering optional RedLINK accessories Performing initial setup Finding your password (Date Code) To add or remove RedLINK accessories To make changes to Installer Setup To perform an Installer Test Thermostat (back view) Password (Date Code) 2

1 Installing the thermostat Thermostat Button NOTE: For best RedLINK performance, mount thermostats at least 2 feet apart. 1.1 Separate wallplate from thermostat. Press button on top and pull to remove the wallplate. Wallplate (back view) 1.2 Mount wallplate as shown. Mount new wallplate using screws and anchors included with the thermostat. Drill 3/16-in holes for drywall. Drill 7/32-in holes for plaster. Wallplate 1.3 Connect power. 1.3a Insert supplied AA alkaline batteries for primary or backup power. NOTE: When the thermostat is NOT used with the Equipment Interface Module or the TrueZONE Wireless Adapter, a C wire is required for RedLINK. Thermostat (back view) 1.3b For 24VAC primary power, connect common side of transformer to C terminal. 3

1.4 Wire the thermostat. Is the thermostat wired directly to the equipment? If the thermostat is wired directly to the equipment: a Refer to the table and wiring diagrams on the next page. b Turn on 24VAC NOW. 24VAC (C wire) is required to connect RedLINK accessories. If the thermostat is used with an Equipment Interface Module or TrueZONE Wireless Adapter, power the thermostat using Rc and C terminals or with batteries. NOTE: The relay outputs and inputs on the thermostat do not function when used with an Equipment Interface Module or TrueZONE Wireless Adapter. 1.5 Remove coin cell battery tab 1.5a Remove tab to activate coin cell battery. NOTE: Coin cell battery saves time and date during a power loss. Coin cell battery tab Wallplate 1.6 Mount thermostat on wallplate. Align thermostat at bottom and snap into place as shown. Thermostat 4

Terminal Designations Conventional System Heat Pump Terminal Description Terminal Description C Common wire from secondary side of cooling transformer (if 2 transformers). C Common wire from secondary side of cooling transformer. Rc* Cooling power. Rc Cooling power. R* Heating power. R Heating power. W Heat Stage 1 O/B Changeover valve for heat pumps. W2 Heat Stage 2 AUX-E Backup Heat/Emergency Heat Y Compressor Stage 1 Y Compressor Stage 1 Y2 Compressor Stage 2 Y2 Compressor Stage 2 G Fan Relay G Fan Relay A U1 / U1 S1 / S1 Connect to Economizer Module or Lighting Panel (TOD). Universal relay for humidification, dehumidification, ventilation, or a stage of heating/cooling. Universal input for a wired indoor, outdoor or discharge sensor. L/A U1 / U1 S1 / S1 Connect to Compressor Monitor, Zone Panel, Economizer Module or Lighting Panel (TOD). Universal relay for humidification, dehumidification, ventilation, or a stage of heating/cooling. Universal input for a wired indoor, outdoor or discharge sensor. K** Connect to K on Wire Saver module. K** Connect to K on Wire Saver module. * Remove factory installed jumper for two transformer systems. ** The THP9045A1023 Wire Saver module is used on heat/cool systems when you only have four wires at the thermostat and you would like the thermostat to be powered with a common wire. Use the K terminal in place of the Y and G terminals on conventional or heat pump systems to provide control of the fan and the compressor through a single wire the unused wire then becomes your common wire. See THP9045 instructions for more information. POWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILATOR NON-POWERED HUMIDIFIER, DEHUMIDIFIER OR VENTILATOR DEHUMIDIFICATION WITH LOW SPEED FAN CONNECTING A HEAT OR COOL STAGE TO U1 Wire the thermostat universal relay to the low speed fan thermostat relay can be set to normally open or normally closed in the thermostat installer setup. Normally open, dry contacts Normally closed, dry contacts 5 U1 terminals are normally open dry contacts when set up for a stage of heating or cooling. or cooling is powered by system transformer. Do NOT transformer.

2 Powering optional RedLINK accessories 2.1 Install batteries in RedLINK accessories. Portable Comfort Control Wireless Outdoor Sensor* Wireless Indoor Sensor* Wireless Entry/Exit Remote* Wireless Vent and Filter Boost Remote* NOTE: If the thermostat is wired directly to the equipment, 24VAC (C wire) is required to connect RedLINK accessories. Turn on 24VAC before performing initial setup in Step 3. 2.2a 2.2 Connect gateway to internet and connect to power. 2.2a Connect RedLINK Internet Gateway to router or modem with Ethernet cable (RJ45). 2.2b Connect gateway s power cord to an electrical outlet that is not controlled by a wall switch. 2.2b 3 Performing initial setup Initial setup options define the type of system you are installing: Residential or commercial Non-zoned or zoned Used with or without an Equipment Interface Module (THM5421) Used with or without the TrueZONE Wireless Adapter (THM4000) 3.1 Follow prompts on the screen to select the appropriate options. NOTE: If you are connecting the thermostat to the TrueZONE Wireless Adapter (THM4000), refer to the TrueZONE instructions to link the thermostat and RedLINK accessories. Then go to Step 3.4. 3.2 When you see the prompt Connect RedLINK Accessories? Touch No or Yes. If you select No, continue to Step 3.4. If you select Yes, you will be prompted to Press Connect on New Accessories. Continue to Step 3.3. 6

3.3 Connect each RedLINK accessory. NOTE: Accessories must be at least 2 feet away from the thermostat during the linking process. 3.3a While the Press Connect message is displayed (listening mode), press and quickly release the CONNECT button on each new RedLINK accessory. 3.3b After a short delay (up to 15 seconds), check thermostat to confirm the connection of each RedLINK accessory. Touch or to review the list. 3.3c Touch Done at the thermostat after all new RedLINK accessories are connected. NOTE: Thermostat displays a countdown timer while in the listening mode. If it detects no activity for 15 minutes, it exits listening mode. Listening mode 3.4 Finish the initial setup. Finish the setup by selecting the desired options. Touch Done after you select the last option you want to change. The thermostat now displays its Home screen and the thermostat setup is complete. 7

4 Finding your password (Date Code) To add or remove RedLINK accessories To make changes to Installer Setup To perform an Installer Test Thermostat (back view) Finding your password You can find the date code on the back of the thermostat, or 1 Touch Menu. Password (Date Code) 2 Select Dealer Information. 3 Scroll down to see the Date Code. Linking RedLINK accessories to the thermostat 1 Touch Menu. 2 Select Installer Options. 3 Enter password (date code) and touch Done. 4 Select Wireless Manager. 8

5 Select Add Device. The screen displays Press Connect on New Accessories. The thermostat is now in listening mode. NOTE: Accessories must be at least 2 feet away from the thermostat during the linking process. 5a Press and quickly release the CONNECT button on each new RedLINK accessory. 5b After a short delay (up to 15 seconds), check thermostat to confirm the connection of each RedLINK accessory. Touch or to review the list. 5c Touch Done at the thermostat after all new RedLINK accessories are connected. NOTE: Thermostat displays a count-down timer while in the listening mode. If it detects no activity for 15 minutes, it exits listening mode. Listening mode Making changes to Installer Setup and performing an Installer Test NOTE: Use a microsd card to save set up time. See next page. 1 Touch Menu. 2 Select Installer Options. 3 Enter password (date code) and touch Done. 4 Select Installer Setup or Installer Test. 5 Follow prompts on the screen to select the desired setup options or to perform an equipment test. 9

Using a microsd card for setup, data logs and software upgrades Use a microsd (secure digital) card to save setup time by loading Installer Setup settings, Dealer Information, Holiday Schedules, and Custom Reminders to multiple thermostats. For troubleshooting help, you can save the thermostat Data Logs (Alerts Log and Interaction Log) to a microsd card - then view them on your computer. Also use the microsd card to upgrade the thermostat software. Loading Dealer Information and New Thermostat Software: 1 Visit http://thermostatsetup.honeywell.com Computer to enter your dealer information or load new thermostat software. 2 Connect a microsd USB Adapter to your computer to download the file(s). 3 After the file(s) are downloaded, remove the microsd card from the adapter and insert into thermostat. To use the microsd card in the thermostat: 1 Slide card into the bottom of thermostat. 2 Select the item to load or save. 3 Follow the prompts on the screen. To add information from the card to the thermostat, select Load from SD Card. To put thermostat information on the card, select Save to SD Card. 4 When you are finished, touch Done, then Home, and remove the microsd card. USB adapter Thermostat microsd card microsd card To replace a thermostat When you replace a thermostat, you must reset the RedLINK accessories before connecting them to the new thermostat. Follow the instructions below: At the Portable Comfort Control: Press and hold the blank space (or arrow) in the lower right hand corner of the screen until the display changes (hold for about 4 seconds). Press REMOVE, then YES to disconnect from the old thermostats. To reconnect the thermostat, go to Step 3.2. At the Indoor Sensor, RedLINK Internet Gateway, Entry/Exit Remote, Vent-Filter Boost Remote or TrueSTEAM Wireless Adapter: Press and hold the CONNECT button on the accessory until the status light glows amber (hold for about 10 seconds). To reconnect the thermostat, go to Step 3.2. At the Equipment Interface Module (EIM): Press and hold the CONNECT button on the EIM until the CONNECTED LED glows amber (hold for about 10 seconds). Follow the prompts on the screen to connect the new thermostat to the EIM. 10 Portable Comfort Control Press and hold

Specifications and replacement parts Operating Ambient Temperature Thermostat: 32 to 120 F (0 to 48.9 C) Portable Comfort Control: 32 to 120 F (0 to 48.9 C) Wireless Outdoor Sensor: -40 to 140 F (-40 to 60 C) Wireless Indoor Sensor: 0 to 120 F (-17.8 to 48.9 C) -For Optimal Battery Life: 35 to 114 F (1.7 to 45.6 C) Equipment Interface Module: -40 to 165 F (-40 to 73.9 C) Return Air Sensor: 0 to 200 F (-17.8 to 93.3 C) Discharge Air Sensor: 0 to 200 F (-17.8 to 93.3 C) RedLINK Internet Gateway: 32 to 120 F (0 to 48.9 C) Operating Relative Humidity Thermostat: 5% to 90% (non-condensing) Portable Comfort Control: 5% to 90% (non-condensing) Wireless Outdoor Sensor: 0% to 100% (condensing) Wireless Indoor Sensor: 5% to 90% (non-condensing) Equipment Interface Module: 5% to 95% (non-condensing) RedLINK Internet Gateway: 5% to 95% (non-condensing) Physical Dimensions (height, width, depth) Thermostat: 4-15/16 x 4-5/8 x 1-1/8 inches (126 mm x 118 mm x 29 mm) Equipment Interface Module: 9-5/16 x 4-13/16 x 1-19/32 inches (91 x 147 x 42 mm) Wireless Outdoor Sensor: 5 x 3-1/2 x 1-11/16 inches (127 x 89 x 43 mm) Wireless Indoor Sensor: 2-7/8 x 1-7/8 x 15/16 inches (74 x 48 x 24 mm) Portable Comfort Control: 6-1/4 x 3-1/8 x 1-5/8 inches (158 x 80 x 38 mm) RedLINK Internet Gateway: 6 x 4-7/8 x 2-1/2 inches (152 x 124 x 64 mm) RedLINK Communication Frequency: 900 Mhz frequency range Re-Sync Time: RedLINK devices re-establish communication within 6 minutes after AC power resumes. Electrical ratings Terminal Voltage (50/60 Hz) Max. Current Rating W - OB 18 to 30 VAC and 750 mvdc 1.00A Y (cooling) 18 to 30 VAC 1.00A G (fan) 18 to 30 VAC 0.50A W2 - Aux (heating) 18 to 30 VAC 0.60A Y2 (cooling) 18 to 30 VAC 0.60A A-L/A (output) 18 to 30 VAC 1.00A U1/U1 30 VAC max. 0.50A Accessories and replacement parts Accessories / Replacement Parts Equipment Interface Module Wireless Adapter for TrueZone, TrueSteam, or extend wireless range of EIM RedLINK Internet Gateway Wireless Entry/Exit Remote Wireless Vent and Filter Boost Remote Portable Comfort Control Wireless Outdoor Sensor Wireless Indoor Sensor Wireless Outdoor Sensor 10k ohm NTC Wired Wall-mount Indoor Sensor 10k ohm NTC Wired Flush-mount Indoor Sensor 20k ohm NTC Wired Wall-mount Indoor Sensor 20k ohm NTC Wired Wall-mount Indoor Sensor 10k ohm NTC Supply or Return Air Sensor 10k ohm NTC Supply or Return Air Sensor 20k ohm NTC Supply or Return Air Sensor 20k ohm NTC Cover Plate (covers marks left by old thermostats) Wire Saver Module 11 Part Number YTHM5421R1010, THM5421R1021 THM4000R1000 THM6000R1002 REM1000R1003 HVC20A1000 REM5000R1001 C7089R1013 C7189R1004 C7089U1006 C7189U1005 C7772A1004, C7772A1012 TR21 TR21-A C7735A1000 C7041 C7770A1006 THP2400A1019 THP9045A1023

Stages Model Numbering TH8321 TH8320 TH8110 3H/2C HP 2H/2C CONV 3H/2C HP 2H/2C CONV 1H/1C HP 1H/1C CONV Residential or Commercial Dual Powered - C Wire or Battery Onboard Humidity Sensor Number of Universal Relays 1 0 0 Number of Universal Sensor Inputs 1 1 1 Economizer / TOD Output Works with Optional Equipment Interface Module* Works with Optional TrueZONE Wireless Adapter* * The relay outputs and inputs on the thermostat do not function when used with an Equipment Interface Module or the TrueZONE Wireless Adapter. * If the thermostat has been setup WITHOUT an Equipment Interface Module or the TrueZONE Wireless Adapter and you would like to add one, you must reset the thermostat back to factory defaults. Press MENU > Installer Options > scroll down to select Reset to Defaults. DISCONNECT POWER BEFORE INSTALLATION. Can cause electrical shock or equipment damage. This thermostat contains a Lithium battery which may contain Perchlorate material. Perchlorate Material special handling may apply. See www.dtsc.ca.gov/hazardouswaste/ perchlorate MERCURY NOTICE: If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash. Contact the Thermostat Recycling Corporation at www.thermostat-recycle.org or 800-238-8192 for information on how and where to properly and safely dispose of your old thermostat. Must be installed by a trained, experience technician. Read these instructions carefully. Failure to follow these instructions can damage the product or cause a hazardous condition. Need Help? For assistance please visit http://customer.honeywell.com, or call toll-free: 1-800-468-1502 (residential installation) 1-888-245-1051 (commecial installation) Scan for more information Automation and Control Systems Honeywell International Inc. 1985 Douglas Drive North Golden Valley, MN 55422 http://customer.honeywell.com U.S. Registered Trademark. 2012 Honeywell International Inc. 69-2760 01 M.S. 11-12 Printed in U.S.A.