Switch Actuator, 8-fold, 10 A, MDRC AT/S 8.10.1, GH Q631 0075 R0111



Similar documents
Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

ABB i-bus EIB / KNX EIB Monitoring Unit EUB/S 1.1

ABB i-bus EIB / KNX Switch Actuator Modules for the Room Controller SA/M ES/M , ES/M

ABB i-bus EIB Logic Module LM/S 1.1

Product Manual. ABB i-bus KNX. Universal Dim Actuator, MDRC UD/S Intelligent Installation Systems ABB

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Busch-Watchdog Presence EIB Type:

Time functions. Functions of the relay. instabus EIB Application program description. September A1 Binary 510D01

Shutter Actuator, 8-fold, 230 V AC, MDRC JA/S , GH Q R0111. ABB i-bus EIB / KNX

ABB i-bus EIB / KNX DALI-Gateway DG/S 8.1

Inwall Room Temperature Unit

Application Unit, MDRC AB/S 1.1, GH Q R0111

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

Inwall 4 Input / 4 Output Module

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

ABB i-bus KNX Security Terminals MT/U , MT/S M and M Product Manual

Product and functional description

ABB i-bus KNX SA/S Switch Actuators Product Manual

ABB i-bus KNX Fan Coil Controller FC/S 1.1

ABB i-bus EIB Universal Interfaces US/U 4.2 US/U 2.2

Movement/monitoring 1307/1.0 (6325xx)

HDL KNX / EIB BUS. Switch Actuators. Guangzhou Hedong Electronic Co.,Ltd (HDL) 1/50

DALI RC BASIC SO. Control unit Operating instructions

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

HERZ-Thermal Actuators

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus KNX DALI-Gateway DG/S 8.1

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Push button 3gang standard flush-mounted xx

38 Series - Relay interface modules A

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

IntesisBox KNX Modbus TCP master

MasterINTERFACE 39 Series - Relay interface modules

How To Use A Power Supply On A Powerline 2.2 (Ai)

38 Series - Relay interface modules A

MasterINTERFACE 39 Series - Relay interface modules

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Safety technique. Emergency stop module BO 5988 safemaster

Light scene push button 8gang comfort flush-mounted xx

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

13 SERIES. Electronic step relays A

TCR easy Plus Alarm. Operating Instructions

Safety automation solutions

93.68/ Time scale: from 0.1s to 6h Multi-function For use with (EMR) and (SSR) relays. Screw terminal and push-in terminal

ABB i-bus EIB / KNX Weather Station WS/S 4.1

80 Series - Modular timers 16 A. Features

IntesisBox KNX Modbus RTU master

Cable Plug acc. to DIN EN , Form A

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

is then retained absolutely without interruption.

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Safety Manual BT50(T) Safety relay / Expansion relay

ABB i-bus EIB / KNX DALI-Gateway DG/S 1.1

E-STOP relays, safety gate monitors

LINETRAXX VMD460-NA. Network and system protection (NS protection) for monitoring the power feed-in of power generation systems

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Pluggable interface relays CR-P Pcb relays

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Operating instructions IV / 2007

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

CONFIGURABLE SAFETY RELAYS

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

RY2 miniature industrial relays

PRODUCT MANUAL LUMENTO X4 LED. LED Controller ZN1DI-RGBX4. Program version: 1.0 Manual edition: a

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

Quick Connect. quick - simple - efficient.

IntesisBox KNX LG Air Conditioning

Transmitter Actuator 230V wave UP 560. Operation

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Automatic start of a generator

Electric Rotary Actuator - On/Off or programmable control actuator

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Push button 2, 3, 5gang with room thermostat (RTR) and display flush-mounted xx, xx, xx

IntesisBox KNX - LON

KNX Panasonic Air Conditioners

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

AC-115 Compact Networked Single Door Controller. Installation and User Manual

Fixed - Over/Under voltage limits, ( ) U N respectivity Link selectable - 5 min or 10 min delay. Fixed limits

48 SERIES Relay interface modules 10 A

15 Series - Electronic step relay and dimmer. Features SERIE

Panel Meters and Controllers Modular Panel Meter Type EDM 35

34 Series - Slim electromechanical PCB relays 6 A. Features SERIES 34.51

ABB STOTZ-KONTAKT GmbH ABB i-bus KNX Switch Actuators SA/S

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Combi B Alarm box. Mounting instructions

Belimo Gateway MP to Modbus RTU - UK24MOD

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

Transcription:

, GH Q631 0075 R0111 The 8-fold switch actuator is a DIN rail mounted device for insertion in the distribution board. It is connected to the EIB via a bus terminal. In the event of bus voltage failure, the actuator can activate the load circuit (e.g. for workplace or emergency lighting). SK 0181 B 02 The device does not require an additional power supply. It switches eight independent groups of electrical loads with eight floating contacts. The following functions can be implemented using the parameter settings in ETS2: Selection of default position on bus voltage failure and recovery, Inversion of the outputs, 5 Logic operation, 5 Status response, ON/OFF delay and staircase lighting function. Technical data Power supply EIB 24 VDC, via the bus line Outputs 8 floating contacts Nominal voltage min. 5 V DC up to max. 253 V AC, 50 60 Hz Nominal current at 5 V DC min. 100 ma Nominal current at 10 V DC min. 10 ma Nominal current at 24 V DC min. 1 ma Nominal current at 230 V AC max. 10 A per output Operating and display elements Red LED and push button for entering the physical address Connections Load circuit 2 screw terminals each output Wire range: 0.2 2.5 mm 2 finely-stranded 0.2 4.0 mm 2 single core EIB Bus connecting terminal (supplied) Type of protection IP 20, in accordance with EN 60 529 Ambient temperature range Operation - 5 C 45 C Storage -25 C 55 C Transport -25 C 70 C Design Modular installation device, prom Housing, colour Plastic housing, grey Mounting on 35 mm mounting rail, DIN EN 50022 Dimensions 90 x 144 x 64 mm (H x W x D) Mounting depth/width 68 mm / 8 modules at 18 mm Weight 0.6 kg Certification EIB-certified CE norm in accordance with the EMC guideline and the low voltage guideline Page 1 of 8

, GH Q631 0075 R0111 Application programs Number ofmax. number ofmax. number of communication objects group addresses associations Switch Logic Status Time /6 24 35 36 5 5 Wiring diagram SK 0119 Z 02 1 Programming push button and LED 3 Connecting terminals for 2 Marker tags outputs A H 4 Bus connecting terminal Note Caution: Prior to programming the according actual version of ETS2 V1.1 or higher must be installed on the commissioning-pc. If this is not carried out, the device cannot function and can no longer be programmed. In order to avoid the danger of electric shock due to feedback from various external conductors, an all-pole disconnection must be complied with. The basic time delay is extended if the outputs are switched several times in succession. Page 2 of 8

, GH Q631 0075 R0111 Switch Logic Status Time /6 Selection in ETS2 ABB Output The application program makes the same number of parameters and communication objects available for each output. Depending on the settings selected in the individual parameters, various communication objects and parameters are displayed or hidden. Switch In the default setting, the actuator switches the relay on when it receives a 5 Binary output, 8-fold telegram with the value 1 and swit- 5 ches it off on receipt of a telegram with the value 0. If the parameter Switching mode is set to normally closed contact, the actuator switches the relay on when it receives a telegram with the value 0 and switches it off on receipt of a telegram with the value 1. Status The individual outputs can send their status on the bus. The parameter Operation mode must be set to switch with active status feedback in order to do so. In this mode, the current output status is sent via a further communication object Output... / Status telegr.. Depending on the setting selected in the parameter Send status feedback, this object can always send its status on the bus or only if the value changes. In the setting always, if the Switch object receives a telegram that does not cause a change at the output, the status object continues to send, regardless of its status. This status signal is also sent even if the same status has previously been sent. In the setting only if value changes, the output status is only sent after a change in the output value. Logic A logic AND or a logic OR function can be selected with the parameter Logical connection. In both cases, ETS2 displays an additional communication object for the output. The actuator then links the values of communication objects 0 and 8 for output A and objects 1 and 9 for output B etc. and switches the relay according to the result. The parameter Invert object no.... is available to implement for example a logic AND or logic OR function with an inverted input. Normally all communication objects have the value 0 after bus voltage recovery. If a logical connection has been assigned, it is possible to specify a definite value using the parameters Value of object no. 8/.../no. 15 at bus voltage recovery. The logical connection is evaluated immediately after bus voltage recovery. Time A time function can be assigned separately to each output. The parameter Time function must therefore be activated. In case a time function is assigned, it is possible to choose between a staircase lighting function and an ON/OFF delay. If a logical connection has already been assigned, only an ON and/or OFF delay can be assigned. The time for the staircase lighting function and the ON/OFF delay is calculated using a base and factor. The smallest possible base and the largest possible factor should be selected when setting these two values. It is also possible to invert the status response. As a result, a 0 is sent after switching on while a 1 is sent after switching off. The following applies for both time function: after the receipt of each telegram that triggers a time function, the respective time function is restarted. Staircase lighting function The staircase lighting function is activated by a telegram with the value 1 at the Switch communication object. After the set time, the output is automatically switched off again. Page 3 of 8

, GH Q631 0075 R0111 In addition, it is possible to activate or deactivate the staircase lighting function via the communication object Operation mode. The parameter Staircase lighting function can be activated/deactivated by object no. must be set to yes so that the communication object Operation mode can be enabled. If a 0 is sent to this object, the staircase lighting function is activated. If a 1 is sent, it is deactivated. 5 5 If the staircase lighting function is activated and a 1 is sent to the Operation mode object, the staircase lighting function remains active until the set period has elapsed. It is then deactivated and the actuator output can be switched on permanently with a 1 to the Switch communication object or permanently switched off with a 0. Default The default position of the relay contact on bus voltage failure and recovery can be set separately for each output. The two parameters Preferred position at... are available for this purpose. This setting refers to the relay contact and is independent of the setting normally opened contact or normally closed contact that has been selected for the switching mode. Bus voltage failure/recovery There is the possibility with the general parameter Inactive waiting time after bus voltage recovery to set the period after which the execution or sending of incoming telegrams shall be triggered again after bus voltage recovery. If the output is switched on and a 0 is sent to the Operation mode object, the staircase lighting function switches on and the output is switched off after the preset time. With the parameter Invert object no...., it is also possible to invert the Operation mode object. In this case, the staircase lighting function switches on with a 1 and switches off again with a 0. ON/OFF delay If the type of the time function is set to switch ON/OFF delay, the output switches on with the set ON delay after the receipt of a 1 at the Switch communication object. If a 0 is received at the Switch object, the output switches off with the set delay. If a logical connection has been assigned, the ON delay only becomes active once the logical condition has been met. The OFF delay is only active when the logical condition is no longer being met. The behaviour after bus voltage recovery can be set separately for each output with the parameter Value of obj. no.... at bus voltage recovery. Directly after bus voltage recovery, the individual outputs assume the set default positions of the contacts. During the inactive waiting time, incoming telegrams are registered but not evaluated. Once the waiting time has elapsed, the objects assume the value that has been defined in the parameters Value of obj. no.... at bus voltage recovery. If however this parameter has been set to read value via EIB, the actuator sends a read telegram and then assumes the value of the response telegram. If the parameter Preferred position after inactive waiting time is set at depending on obj. no., the output contact is switched according to the value of object no.. If the parameter Preferred position after inactive waiting time is set at unchanged, the output contact remains in the position that has been set for bus voltage recovery until new telegrams are received via the EIB. After the programming of the device the default position of the outputs is open (switched off). In the following inactive waiting time the devices behave as after bus voltage recovery. Page 4 of 8

, GH Q631 0075 R0111 0 1 bit Output A Switch 1 1 bit Output B Switch 2 1 bit Output C Switch 3 1 bit Output D Switch 4 1 bit Output E Switch 5 1 bit Output F Switch 6 1 bit Output G Switch 7 1 bit Output H Switch 5 with status response 5 16 1 bit Output A Status telegr. 17 1 bit Output B Status telegr. 18 1 bit Output C Status telegr. 19 1 bit Output D Status telegr. 20 1 bit Output E Status telegr. 21 1 bit Output F Status telegr. 22 1 bit Output G Status telegr. 23 1 bit Output H Status telegr. with inverted status response 16 1 bit Output A Invert status telegr. 17 1 bit Output B Invert status telegr. 18 1 bit Output C Invert status telegr. 19 1 bit Output D Invert status telegr. 20 1 bit Output E Invert status telegr. 21 1 bit Output F Invert status telegr. 22 1 bit Output G Invert status telegr. 23 1 bit Output H Invert status telegr. with logical OR connection 0 1 bit Output A Logical OR connection 1 1 bit Output B Logical OR connection 2 1 bit Output C Logical OR connection 3 1 bit Output D Logical OR connection 4 1 bit Output E Logical OR connection 5 1 bit Output F Logical OR connection 6 1 bit Output G Logical OR connection 7 1 bit Output H Logical OR connection 8 1 bit Output A Logical OR connection 9 1 bit Output B Logical OR connection 10 1 bit Output C Logical OR connection 11 1 bit Output D Logical OR connection 12 1 bit Output E Logical OR connection 13 1 bit Output F Logical OR connection 14 1 bit Output G Logical OR connection 15 1 bit Output H Logical OR connection Page 5 of 8

, GH Q631 0075 R0111 with logical AND connection 0 1 bit Output A Logical AND connection 1 1 bit Output B Logical AND connection 2 1 bit Output C Logical AND connection 3 1 bit Output D Logical AND connection 4 1 bit Output E Logical AND connection 5 1 bit Output F Logical AND connection 6 1 bit Output G Logical AND connection 7 1 bit Output H Logical AND connection 8 1 bit Output A Logical AND connection 9 1 bit Output B Logical AND connection 10 1 bit Output C Logical AND connection 5 11 1 bit Output D Logical AND connection 5 12 1 bit Output E Logical AND connection 13 1 bit Output F Logical AND connection 14 1 bit Output G Logical AND connection 15 1 bit Output H Logical AND connection with inverted logical connection 8 1 bit Output A Invert logical... connection 9 1 bit Output B Invert logical... connection 10 1 bit Output C Invert logical... connection 11 1 bit Output D Invert logical... connection 12 1 bit Output E Invert logical... connection 13 1 bit Output F Invert logical... connection 14 1 bit Output G Invert logical... connection 15 1 bit Output H Invert logical... connection with activation/deactivation of staircase lighting function 8 1 bit Output A Operation mode 9 1 bit Output B Operation mode 10 1 bit Output C Operation mode 11 1 bit Output D Operation mode 12 1 bit Output E Operation mode 13 1 bit Output F Operation mode 14 1 bit Output G Operation mode 15 1 bit Output H Operation mode with inverted activation/deactivation of staircase lighting function 8 1 bit Output A Invert operation mode 9 1 bit Output B Invert operation mode 10 1 bit Output C Invert operation mode 11 1 bit Output D Invert operation mode 12 1 bit Output E Invert operation mode 13 1 bit Output F Invert operation mode 14 1 bit Output G Invert operation mode 15 1 bit Output H Invert operation mode Page 6 of 8

, GH Q631 0075 R0111 Parameters The default setting for the values is printed in bold type. General: Inactive waiting time after bus 5 s / 10 s / 15 s /... / 60 s voltage recovery: At bus voltage recovery, during this time, no telegrams will be sent and incoming telegrams will not be executed Separate for each output (Output A is used here as an example): Switching mode normally opened contact normally closed contact Operation mode switch 5 switch with active status feedback 5 only if status response is selected: Invert status feedback yes no Send status feedback always only if value changes Logical connection no logical connection logical OR connection logical AND connection only if logical connection is assigned: Invert object no. 8 yes no Value of obj. no. 8 at bus read value via ABB i-bus EIB voltage recovery logic 0 logic 1 Value of obj. no. 0 at bus read value via ABB i-bus EIB voltage recovery logic 0 logic 1 Preferred position at bus voltage contact opened failure contact closed contact unchanged Preferred position at bus voltage contact opened recovery contact closed contact unchanged Preferred position after unchanged inactive waiting time depending on obj. no. 0 Page 7 of 8

, GH Q631 0075 R0111 Parameters The default setting for the values is printed in bold type. Output A - time Time function deactivated activated Note: If a logical function is chosen, no staircase lighting function is available. only if time function is activated: Type of time function staircase lighting switch ON/OFF delay only for staircase lighting function: 5 Time base 130 ms / 260 ms /... / 35 min / 1.2 h 5 Factor for duration of 5 staircase lighting (5...127) Staircase lighting function can yes be activated/deactivated by no object no. 8 only if yes is selected: Invert obj. no. 8 yes no Value of obj. no. 8 at bus read value via ABB i-bus EIB voltage recovery logic 0 logic 1 only for ON/OFF delay: Time base 130 ms / 260 ms /... / 35 min / 1.2 h Factor for switch ON delay 0 (0127) Factor for switch OFF delay 0 (0127) Page 8 of 8