1 IP CONNECT MODULE SIMPLE USER INSTRUCTIONS 1.1 Background Module Connection and Addressing 1.2 Setting UP Simple HTTP Web Server 1.

Similar documents
To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Connecting the DG-102S VoIP Gateway to your network

Prestige 650R-31/33 Read Me First

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

1 Serial RS232 to Ethernet Adapter Installation Guide

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

Prestige 324. Prestige 324. Intelligent Broadband Sharing Gateway. Version 3.60 January 2003 Quick Start Guide

Quick Note 32. Using Digi RealPort with a Digi TransPort Router. UK Support September 2012

T3 Mux M13 Multiplexer

50-Port 10/100/1000Mbps with 4 Shared SFP. Managed Gigabit Switch WGSW Quick Installation Guide

Prestige 314 Read Me First

Setup Manual and Programming Reference. RGA Ethernet Adapter. Stanford Research Systems. Revision 1.05 (11/2010)

User s Manual TCP/IP TO RS-232/422/485 CONVERTER. 1.1 Introduction. 1.2 Main features. Dynamic DNS

ETHERNET WEATHER STATION CONNECTIONS Application Note 33

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Prestige 324 Quick Start Guide. Prestige 324. Intelligent Broadband Sharing Gateway. Version V3.61(JF.0) May 2004 Quick Start Guide

Voice Over Internet Protocol (VoIP) Configuration

ACCESS 9340 and 9360 Meter Ethernet Communications Card ETHER

TCP/IP Converter DDS EX-9132 Operation Manual for 8051 Series

Prestige 623R-T. Quick Start Guide. ADSL Dual-link Router. Version 3.40

Ethernet. Customer Provided Equipment Configuring the Ethernet port.

One Port Serial Server Users Manual Model ESP901, ESP901E

Industrial L2+ Managed Gigabit/ 10 Gigabit Ethernet Switch. IGS-5225 Series. Quick Installation Guide

Connecting and Setting Up Your Laptop Computer

Different Ways of Connecting to. 3DLevelScanner II. A.P.M Automation Solutions LTD. Version 3.0

Vantage RADIUS 50. Quick Start Guide Version 1.0 3/2005

IP SERIAL DEVICE SERVER

Easy Setup Guide for the Sony Network Camera

PRILINK PRI Management System

ReadMe File. Installing the Unified Messaging Application for

LAN / WAN Connection Of Instruments with Serial Interface By Using a Terminal Server

3.5 EXTERNAL NETWORK HDD. User s Manual

1 INTRODUCTION. This document describes the procedure to upgrade LTMR.

Application & Quick-Start Guide

GV-Data Capture V3 Series User's Manual

1. Hardware Installation

ACU-1000 Manual Addendum Replacement of CPM-2 with CPM-4

MODBUS TCP to RTU/ASCII Gateway. User s Manual

WRE6505. User s Guide. Quick Start Guide. Wireless AC750 Range Extender. Default Login Details. Version 1.00 Edition 1,

E-Mon Communication Gateway Utility Instructions for BACnet/mstp

UPS Network Interface. Quick InstallationGuide

Atop ABLELink Ethernet-Serial Server GW51C- MAXI

FINS Gateway For OMRON PLCs

3.5 LAN HDD Enclosure User s Manual

PePWave Surf Series PePWave Surf Indoor Series: Surf 200, AP 200, AP 400

SDN INSTRUCTIONS 07/10, Ver 1.2. Somfy Digital Network (SDN) Installation and Programming

ADSL Router Quick Installation Guide Revised, edited and illustrated by Neo

Chapter 6 Using Network Monitoring Tools

RN-XV-RD2 Evaluation Board

DSA-1000 / PRT-1000 Device Server / Thermal Printer

Follow these steps to prepare the module and evaluation board for testing.

Virtual Integrated Design Getting started with RS232 Hex Com Tool v6.0

EZ-View Network Communications Guide

LS-101 LAN to Serial Device server. User s Manual

PLC training panel (Twido version)

Prestige 660R-6x Read Me First

Wireless LAN g USB Adapter

Ethernet Interface Manual Thermal / Label Printer. Rev Metapace T-1. Metapace T-2 Metapace L-1 Metapace L-2

APPLICATION NOTE. Ethernet Configuration Guide for D-500 D-700

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM Version 1.32r 10/9/2012 USER MANUAL

Internet-bridge XPort

Wireless G Broadband quick install

How to setup the UCW232C Serial WiFi adapter

RS-232/422/485, Power over Ethernet

Using IDENT M System T with Modbus/TCP

1.1 Connection Direct COM port connection. 1. Half duplex RS232 spy cable without handshaking

Intel Active Management Technology with System Defense Feature Quick Start Guide

ECcom. Signal Monitor Communications Software Operations Manual

Chapter 6 Using Network Monitoring Tools

Liebert IntelliSlot Web Cards

Arduino Wifi shield And reciever. 5V adapter. Connecting wifi module on shield: Make sure the wifi unit is connected the following way on the shield:

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

INTRODUCTION FEATURES OF THE ICM

SecureLinx Spider Duo Quick Start Guide

Mobile Router MR600 User Guide

Application Note. Equipment Needed

Kramer Electronics, Ltd. Site-CTRL and Web Access Online User Guide (Documentation Revision 2)

CS 326e F2002 Lab 1. Basic Network Setup & Ethereal Time: 2 hrs

P-660R-TxC Series. ADSL2+ Access Router. Quick Start Guide

Software User Guide UG-461

MODBUS TCP to RTU/ASCII Gateway

Ethernet Port Quick Start Manual

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

Schneider OS-Loader usage via Ethernet or USB.

Broadband Router ESG-103. User s Guide

Serial Over IP Ethernet Device Server

Chapter 10 Troubleshooting

Advantech WebAccess Device Driver Guide. BwSNMP Advantech WebAccess to SNMP Agent (Simple Network Management Protocol) Device Driver Guide

Starting a Management Session

Knowledge Base Article. Integrating ISONAS Access Control System with TagMaster LR-series RFID Readers

EMG Ethernet Modbus Gateway User Manual

7.7 Ethernet Communication (AFPX-COM5)

TDP43ME NetPS. Network Printer Server. Control Center. for Ethernet Module

GE Security. FHSD Monitor / Web Server user manual

Using HyperTerminal with Agilent General Purpose Instruments

Digicom Remote Control for the SRT

Allworx Installation Course

Transcription:

1 IP CONNECT MODULE SIMPLE USER INSTRUCTIONS 1.1 Background 1.1.1 Module Connection and Addressing 1.2 Setting UP Simple HTTP Web Server 1.3 Setting UP RS232 / RS485 Serial Port 1.3.1 Port Configuration 1.3.2 Communications Protocol 1.3.3 Module Unified Address 1.3.4 RS485 Operation 1.3.5 Some Useful Commands 1.3.6 Module Status Register 1.4 IP CONNECT USB to PC Communications 1.4.1 USB Class, Vendor and Product 1.4.2 Connection and Driver Setup 1.4.3 Communications Protocol 2 APPENDICES 2.1 Register Mappings Screen Modules 2.1.1 Btimapped Registers 74 & 75 2.1.2 DIAGNOSTICS Registers 32 to 63 2.1.3 STATUS Register 32 2.2 Register Mappings D1322_13 IP Connect Module

The IP CONNECT Module is a versatile communications interface which allows a PC to inter-work with the Connect Network System of Screen controllers. This document provides simplified instructions on how to connect the IP CONNECT module, and basic usage of the module. For more detailed information consult the document D1322_User_Manal_Ver_1_9.doc 1.1 BACKGROUND The IP CONNECT module connects into the Connect Network in the same way as the other modules, and works with the same addressing scheme. The module can interface with a host PC or controller in a number of ways:- (a) Serial RS232 (b) Serial RS485 (c) USB (d) TCP/IP The module communicates over the serial ports and USB using a simple ASCII protocol. The TCP/IP connection provides a simple HTTP Web Server or can use the Control Port with a Telnet type of application and the same ASCII protocol as for the serial ports Separate ports on the USB and TCP/IP can be linked through to the RS232 port. Data is transmitted transparently between the linked ports. The following ports and connections are available: Interface Connector Port Connections RS232 Link Thru CONNECT RJ12 IN 1 CONNECT RJ12 OUT 1 Control Port RS232 Screw Term 1 Y Y RS485 Screw Term 1 Y USB USB-B D132213_A 1 Y D132213_B 1 Y Y HTTP RJ45 80 3 Y TCP/IP 3002 3 Y TCP/IP 3001 1 Y Y

Module Connection and Addressing The IP module is connected to the Connect Network using the 6wire RJ12 cables. The modules are connected as a daisy chain from each module s OUT socket to the next module s IN socket. EG:- MODULE A IN OU T MODULE B IN OU T IN MODULE C OU T IP CONNECT MODULE IN OU T Each module has 2 addresses: (1) Relative (MAF) address In the example above IP Connect Module Always starts with MAF = 1 MODULE A MAF = 2 MODULE B MAF = 3 MODULE C MAF = 4 (2) Module ID this address is assigned by programming the Module ID Register Module ID can also be programmed using special Quick Configure commands. Module Addresses are always in the range 1 to 9

1.2 SETTING UP SIMPLE HTTP WEB SERVER The IP CONNECT module can be connected to a Local Area Network (LAN) and the HTTP on port 80 can be accessed by a standard Web Browser such as Windows Internet Explorer. The simple web browser allows a user to view and change the module configurations and also to perform some control functions with status updates. The following steps should allow connection to the HTTP web server from a PC STEP 1. Connect the RJ45 port to from the IP CONNECT module to the LAN port of the PC STEP 2. Power-up the IP CONNECT Module. Note if the IP address or subnet mask have been changed in the module then should powerup with the small switch on side of the module depress and then release after a few seconds. This will set the module IP address and subnet mask back to the following factory defaults: DEFAULT IP ADDRESS = 192.168.1.253 DEFAULT SUBNET MASK = 255.255.255.0 DEAFULT GATEWAY = 192.168.1.1 STEP 2A. Change Network Settings in the PC The PC Network Settings must match the IP address (first 3 numbers) and subnet mask of the IP CONNECT module. The last number (eg IP address 34 in the example below must be different) This is done in Windows NT by opening the Control Panel \ Network Connections. Then select the LAN Connection and Right Click to view Properties. Then select Internet Protocol (TCP/IP) and view Properties The following Window should appear. Make a note of the values as these will need to be changed Change the IP Address and Subnet Mask as shown Once the changes are made select OK to save it. STEP 2B An ALTERNATIVE to changing the Network Settings in the PC is to change the Network settings in the IP CONNECT module to match those of the PC & Local Area network. Using the procedure in STEP 2B to view the TCP/IP properties on the PC. Make a note of the IP Address and Subnet Mask. Connect a PC to the RS232 Serial Port or USB (see procedures in next section 1.4).

Then using the Register Set command to change the IP Address (Registers 68 and 69) and Subnet Mask (Registers 70, 71) to the required values. Note the 4 byte address is converted to the 2 integer address as follows:- If the 4 Byte IP address is AAA.BBB.CCC.DDD Then for the CONNECT IP module registers values are set to Register 68 IP Address (H) = AAA x 256 + BBB Register 69 IP Address (L) = CCC x 256 + DDD The subnet mask determines which bits of the IP Address should be matching for the devices to be able to communicate. For small networks it is normally set to 255.255.255.0 This means that the first 4 numbers of the IP Address need to be matching, and the last one should be unique. STEP 3. Run the Web Browser eg Windows Internet Explorer Type the IP Address for the IP CONNECT module into the browser s address bar at the top LHS of the Window. Note : The IP Address should be written for example as http://192.168.1.253 The following Opening screen should then be shown. STEP 4. Enter the User Name and Password The factory Defaults are: User Name: Admin Password: Connect If the Username or password has been changed and forgotten, the IP CONNECT module can be returned to the Factory defaults by powering-up with the side Push-button pressed. Once the Username / Password are successfully entered then the main menu screen will be shown.

1.3 SETTING UP RS232 / RS485 SERIAL PORT 1.3.1 PORT CONFIGURATION The Default settings are :- Baud Rate 9600 Bits 8 Parity None Stop 1 Flow Control None / Hardware Note baud rate may be changed in the configuration registers 1.3.2 COMMUNICATIONS PROTOCOL The Serial Protocol is an ASCII text based protocol which can be accessed by a user using Windows Hyperterm or it can be interfaced to an automated controller Note the default setting is for character echo to be switched off. This may be switched on by sending the command 062 0 3781 <Enter> Responses are returned with the Command number incremented by +100. The second field returns a response code, with the status of the response:- Response STATUS Code 1 Data Valid/Action Completed OK/LEFT PORT 2 Data Valid / More Data to Come/LEFT PORT 3 Data Valid/ Buffer is Full /LEFT PORT 4 Address Error 5 Address Error 6 IP Module is Busy 7 No Module Response 8 Bad Value 1.3.3 MODULE UNIFIED ADDRESS Commands for a particular module require a module address which can be represented in 2 ways: (1) As the Module ID (1 to 9) assigned by programming. (2) As the Relative or MAF address (1 to 9) +16 Eg MAF address 3 becomes Unified Address 3 + 16 = 19.

1.3.4 RS485 OPERATION The module sits in Receive mode and when it Receives a command it switches to TX to send the response and then back to receive. When it switches from RX to TX allow 50ms for slow PC applications. 1.3.5 SOME USEFUL COMMANDS COMMAND DESCRIPTION COMMAND NUMBER VALUE1 VALUE2 VALUE3 READ REGISTER 1 ADDRESS REGISTERE NUMBER WRITE REGISTER 2 ADDRESS REGISTER NUMBER OPERATE IR 20 IR GROUP UP GROUP OPERATE IR 23 IR GROUP DOWN OPERATE MODULE DIRECT UP OPERATE MODULE DIRECT DOWN GET MODULE STATUS GROUP 30 ADDRESS 33 ADDRESS 50 VALUE 1.3.6 MODULE STATUS REGISTER The Module Status register returns the current state of each module. This can show if a module is moving up or down or is stopped at top or bottom When modules are operated, they will transmit a change in their status. The IP CONNECT module receives these status values and stores them in a buffer. This buffer can be Polled (Command 50) regularly to provide a live indication of the module activity. MODULE ACTION STATUS 0 Moving top 1 Moving bot 6 At TOP 7 At BOTTOM 10 Stopped manual 11 Error

1.4 IP CONNECT USB TO PC COMMUNICATIONS 1.4.1 USB CLASS, VENDOR AND PRODUCT The IP CONNECT module (D132217) is supplied with Vendor ID 0x1150 Product ID 8 & 9 Serial Number Always 00000000 Driver Representation USB\VID_1150&PID_0007 The Vendor ID 0X1150 is owned by Don Alan Pty Ltd is made available for use on this product on this instance for this product as it stands. No further right to this vendor ID is provided. The module implements CDC class which means it will appear as a com port on the PC. Although the PC may allow com port parameters such as baud rate to be set they have no effect. 1.4.2 CONNECTION AND DRIVER SETUP For use on most operating systems there is no driver as such as the CDC class licence for the operating system will be invoked. A usbser.inf file is provided that allows easy connection to Microsoft Windows 2000 and later systems. When the USB cable is plugged into the PC, the user will be prompted to install the device information (.inf) file. Select the option Search Specific location and point it to the folder where the usbser.inf file is located. Two virtual COMM Ports are created, and so the driver installation will prompt for the.inf file to be installed twice. Port D132213_A uses the command interpreter Port D132213_B uses the command interpreter This port can also be set for direct link through to the RS232 Port Once the driver is installed a user can access the virtual COMM port using Hyperterm or similar console application. 1.4.3 COMMUNICATIONS PROTOCOL This serial command protocol is essentially the same as for the other Serial RS232 and RS485 ports. Refer Section 1.4 for further details.

2 APPENDICES 2.1 REGISTER MAPPINGS SCREEN MODULES Registers Supported Register No. Description D13221 D13225 D13226 D132217 SPECIAL 0 Special Register Y Y Y Y READ ONLY DEC HEX 1 01 S/W Version Y Y Y Y 2 02 Hardware Version Y Y Y Y 3 03 Batch Number Y Y Y Y 4 04 Serial Number Y Y Y Y 5 05 Module Type Y Y Y Y 6.. 7 06.. 07 Spare 8.. 15 08.. 0F Bit map of Y Y Y Y supported registers 16.. 31 Spare DIAGNOSTICS DEC HEX 32 20 STATUS See Y Y Y Y Table 2.1.3 33 21 COMMANDS Y Y Y Y See Table Error! Reference source not found. 34 22 Left Packet Errors Y Y Y Y 35 23 Right Packet Errors Y Y Y Y 36 24 Motor Operates Up Y Y Y 37 25 Motor Operates Y Y Y Down 38 26 Motor Operate Y Y Y Time (Minutes) 39 27 Motor Current Y Max 40 28 Motor Current Y Ave 41 29 Number of Power- Y Y Y Y Restarts 42 2A Poweron Secs- Lo Y Y Y Y 43 2B Poweron Secs -Hi Y Y Y Y 44 2C Failures timeout Y Y Y 45 2D Failures - current Y 46 2E Process_State Y Y Y Y 46..63 2C..3F Spare

PROGRAMMING - EEROM DEC HEX 64 40 Magic 1 (Fixed Y Y Y Y 43981) 65. 41 Operation PIN Y Y Y Y 66. 42 Programming PIN Y Y Y Y 67 43 Partial Pos 1 Lo Y Y Y 68 44 Partial Pos 1 Hi Y Y Y 69 45 Partial Pos 2 Lo Y Y Y 70 46 Partial Pos 2 Hi Y Y Y 71 47 SWITCH MODE Y Y Y Y 72 48 Partial 1 Open Y Y Y Mode 73 49 Partial 2 Open Y Y Y Mode 74 4A SWITCH GROUP Y Y Y Bitmapped Register See below 75 4B IR GROUP Y Y Y Bitmapped Register See below 76 4C Timer Up Y Y Y 77 4D Timer Down Y Y Y Y 78 4E MODULE_ID Y Y Y 79 4F Motor Current Trip Y Threshold 80 50 Motor Run Y Y Y Timeout 81 51 Diagnostics Log Y Y Y Y Time 82 52 Time_delay_up Y Y Y (100mS) 83 53 Time_delay_down Y Y Y (100mS) 84 54 Magic 2 (fixed Y Y Y Y 47637) 83..127 53.. 7F Spare

2.1.1 BITMAPPED REGISTERS 74 & 75 The group is selected by setting the respective binary bit. The number is then the decimal conversion of the binary number Bit N0 B8 B8 B7 B6 B5 B4 B3 B2 B1 B0 Group GRP9 GRP8 GRP7 GRP6 GRP5 GRP4 GRP3 GRP2 GRP1 0 Value 512 256 128 64 32 16 8 4 2 0 Alternatively, simply add the table values assigned to the required groups 2.1.2 DIAGNOSTICS REGISTERS 32 TO 63 These registers provide important diagnostic information about the current state of the module, the operating conditions and various fault conditions. The Diagnostics Registers are saved to EEPROM every 3600 seconds (1 Hour). This period may be changed with Register 0x51. 2.1.3 STATUS REGISTER 32 The STATUS register is special in that it is used for feeding back response information to the Connect IP module. Response Type No MODULE FUNCTION D13221 D13225 D13226 D132217 0 Moving top Moving top OK Moving top 1 Moving bot Moving bot Moving bot 2 Moving PP1 Moving PP1 Moving PP1 3 Moving PP2 Moving PP2 Moving PP2 4 Moving PPT Moving PPT Moving PPT 5 Moving PPB Moving PPB Moving PPB 6 At TOP At TOP At TOP 7 At BOTTOM At BOTTOM At BOTTOM 8 At PP1 At PP1 At PP1 9 At PP2 At PP2 At PP2 10 Stopped manual Stopped manual Stopped manual 11 Error Error Error Error 12 13 Fail-timeout Fail-timeout Fail-timeout 14 Fail current Fail current Fail current 15 Rattle Rattle Rattle 16 At PPB At PPB At PPB

2.2 REGISTER MAPPINGS D1322_13 IP CONNECT MODULE Register No. Description SPECIAL 0 Special Register READ ONLY 1 S/W Version 2 Hardware Version 3 Batch Number 4 Serial Number 5 Module Type 6.7 Spare 8..15 Bit map of supported registers 16.. 31 Spare DIAGNOSTICS 32 Status 33 COMMAND Future 34 Left Packet Errors 35 Right Packet Errors 36..40 Spare 41 Buffer IP CONNECT Module ID (MAF=2) 42 Buffer Module ID MAF=2 43 Buffer Module ID MAF=3 44 Buffer Module ID MAF=4 45 Buffer Module ID MAF=5 46 Buffer Module ID MAF=6 47 Buffer Module ID MAF=7 48 Buffer Module ID MAF=8 49 Buffer Module ID MAF=9 50 Spare 51 Buffer IP MODULE STATUS (MAF=1) 52 Buffer Module STATUS MAF=2 53 Buffer Module STATUS MAF=3 54 Buffer Module STATUS MAF=4 55 Buffer Module STATUS MAF=5 56 Buffer Module STATUS MAF=6 57 Buffer Module STATUS MAF=7

58 Buffer Module STATUS MAF=8 59 Buffer Module STATUS MAF=9 60..63 PROGRAMMING - EEROM 64 RS232 Baud Rate /10 65 RS232 bitmapped options B0 Echo on B1 Handshake B2 1=7 or 0=8 bits B3 0=1 Stop bit 1=2 Stop Bits 66 RS485 Baud Rate /10 67 RS485 bitmapped options B0 B1 B2 1=7 or 0=8 bits B3 0=1 Stop bit 1=2 Stop Bits 68 IP Address (H) 69 IP Address (L) 70 Subnet mask (H) 71 Subnet mask (L) 72 Gateway (H) 73 Gateway (L) 74 MAC Address (H) 75 MAC Address (M) 76 MAC Address (L) 77 Diagnostics Log Time (Seconds) 78 Module ID 79 Buffer Refresh Rate (Seconds) 80 Bitmapped Options B0 AMX Discoverable Enabled B1 RS232 Linked to TCP/IP B2 RS232 Linked to USB Spare 81.. 127 Spare MODULE ID BUFFER and MODULE STATUS BUFFER Registers are special registers used to store quick lookup of particular module information.