Mechanics and electronics perfectly combined. Safety can be intelligent.

Similar documents
PK-01. Standalone door control module. SATEL sp. z o.o. ul. Schuberta Gdańsk POLAND tel

contents Leading the way in intelligent automation INELS Wireless? Why Click Accessories Complete control

Digital Keypad Use s Manual

Shunt lock function 3066

PAC1 Door Access Controller

INTRIC E. D Vers. 02 SELF-LEARNING ROLLING-CODE EXTERNAL RECEIVER

FIREDEX Conventional Fire Panels

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

GSM Alarm System User Manual

Product Information Sheet UH36 Hi Pot Tester

Hotel Smart Locking Management System

INSTALLATION MANUAL XM3 Reader

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Instruction Manual. This Manual covers the use of: SmartSwitch Servo Kit. DCC Stationary Decoder PLEASE READ THESE INSTRUCTIONS FULLY BEFORE USE

garage door operators

CKM-EP2500, CKM-EP1501, and CKM-EP1502 Mercury Network Controllers

ABLOY EXIT. Functional and technical descriptions Single and double leaf doors. An ASSA ABLOY Group brand

V1504 Vertical Platform Lift OWNER S MANUAL

MOOVO, BEAUTIFULLY PRACTICAL

GSM ATT Modules Simply effective remote control

VARIO PROX CARD READER INSTALLATION MANUAL

VIPER 400 ENGLISH ENGLISH

ELITE-L Series. ELITE - Low Voltage / Dry contact Remote Control System

Programming A PLC. Standard Instructions

Operating Guide. Alert 8D Version 8 Zone Controller Arrowhead Alarm Products Ltd

CHAPTER 1. GETTING STARTED... 1

ACCESS CONTROL SECURITY SYSTEMS TRANSMITTERS SHOW-WINDOWS PROTECTION COMPONENTS FOR GATES AUTOMATION

WIRELESS MAGNETIC CONTACT

EQUIPMENT SPECIFICATIONS

Anti Shock CD / USB / SD Card Reader / Remote Control Player RM-CD

Secure Keypads for access control

Getting to Know Xsight Home Screen and Everyday Use Settings PC Setup

Product Information Sheet UH28CS-12kV Hi Pot Tester

V1504 Vertical Platform Lift OWNER S MANUAL

AC-115 Compact Networked Single Door Controller. Installation and User Manual

FC6 FOOT CONTROLLER OWNER S MANUAL

GSM ALARM SYSTEM GCM 8

PowerCode Wireless. Fully supervised wireless system. Features


ALWAYS THE SAFE CHOICE! Electronic door locking systems.

Transponder reader CÉLIANE TECHNICAL GUIDE

SYSTEM 7000 IRIS+ USER MANUAL

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

ReSound Unite TV FREQUENTLY ASKED QUESTIONS. Setup & Configuration. Use & Operation. Troubleshooting

Connecting your Victron product to a computer with VE Configure

Shunt lock function 3066 Operator Instructions

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Electric Landing Gear controllers and sequencer LGC12 / LGC 13C

Elvey is a leading distributor of electronic security equipment in Africa. Our vision is to assist in the protection of people and property by

Temperature & Humidity SMS Alert Controller

Always on the Lookout Perfect Protection against Burglary

40.3. Control Relays and Timers

ACCESS CONTROL SYSTEM

Programming and Installation Instructions. Passed ISO international system ratification

MAGICAR M871A. Car alarm with two-way remote User s guide

Adaptability to Enhanced Security

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

wireless alarm system reliable protection for small-size buildings

PUSH BUTTON START INSTALLATION MANUAL

Solution Ultima ICP-CC488 Home security you can rely on

PowerLogic Sub Meter Display (SMD and SMDOPN)

IN-OUT Thermometer with Cable Free Sensor and Clock

FSLIMRF

3500/93 System Display

LUCCI AIRFUSION QUEST II CEILING FAN

USER MANUAL

Adaptability to Enhanced Security

BSCAN DW VOX SAVE BEEP CHANNEL CALL VOX

Monitoring and security of vehicles

POCKET READER AND POCKET READER EX MANUAL

Keymaker_for_ML. Connect adapter to USB port of your PC and install drivers. Find it on CD.

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

enter the smart house

RUST ELECTRONICS LTD. Remote Switching Unit RCU-O4

GSM HOME SECURITY SYSTEM

Programming Logic controllers

PROFESSIONAL HOME ALARM SYSTEM. Important! Please read these instructions carefully.

Everything you need for protection scheme testing

Points Position Indicator (PPI1) for Points Motors with Common Ground

Key in Knob & Key in Lever

e-ask System (electronic Access & Security Keyless-entry)

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.3

Shortform Catalogue. Solutions for appliance & electronic applications. rocker switches. lever. switches. push. switches.

BIBUS VOP. large blocks of flats with switchboard and mixed mainly audio systems. Ideal for door phone systems with up to 250 users.

Operating Manual for the Electronic Built-in Interval Timer. Micro II (Countdown Timer)

Mini Timer Owner's Manual. Model MT13A

BARCODE TICKET SOLUTION RF CARD SOLUTION MAGNETIC TICKET SOLUTION

Hills wireless security alarm DIY range

ZC-24DO CANopen I/O Module: 24 Digital Outputs

INTRUSION DETECTION SYSTEM Section

3. Security System Requirements

FMT600BT Transmitter

SECTION LOW VOLTAGE LIGHTING CONTROLS

RFID Based Solution for Asset Tracking, Location Awareness and Safety Management

OZW30. Central Unit SYNERGYR

Input module, input/output module

NC-12 Modbus Application

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation

PROBA 4. In control of banana ripening. World leaders in process control.

Transcription:

«There are those who look at things the way they are and ask Why? I dream of things that never were and ask Why not?». J.F. Kennedy Mechanics and electronics perfectly combined. Safety can be intelligent.

The new FIAM x1r electronic locks are interchangeable with dimensional standards adopted for most common mechanical locks, have the same range of accessories and the electrical connections required, both during construction of the door and during installation, are much simpler than you would think at this moment in time... Opening a car by simply approaching it, and starting it with an electronic code generated by a personal card rather than with a traditional key is now an increasingly more common event within everybody s reach. A small revolution that will radically change our habits is also taking place in the field of security doors. Today safety is also intelligent.

The basic mechanical lock has been enhanced with electronic components of the latest generation, meaning access to our homes can be intelligent, but above all practical and safe, offering a radical change in performance. Security doors can now recognise us, they open on our arrival and close as soon as we enter our home. They can communicate with the alarm system if required. All automatically. All in absolute safety. Why not open the door to technology and innovation? Why not?

The experience acquired by FIAM over the last 50 years, and the knowledge gained in the field of electronics with the creation of the Hi-Tech laboratory, have allowed them to create a truly innovative and reliable product. The stress tests and other tests to which the x1r has been subjected to allow us to offer the greatest technological results possible at this moment in time. The alkaline battery-operated model guarantees no less than 23,000 opening and closing cycles in optimum working conditions. Take a look at the gear release device: a brilliant system, as simple as it is precise, ensuring that the door can always be opened using the mechanical key, even in critical situations.

Even assembly of the various components has been carefully studied and some very practical improvements have been made. Both the TAG, and the keypad and programming logic positioned on the internal side of the door, have been inserted into practical Ø 45 mm boxes that can in turn be adapted and installed exactly like normal faceplates using concealed screws. Simple electrical connections make assembly quick and easy. The faceplates are made of brass and are available in various finishes, including PVD if required. The new x1r 2008 models, unlike the previous models, offer various ways of managing the access code. Based on your specific needs you can choose whether to create a door that can be opened using a transponder reader (TAG), a numeric code (backlit keypad for optimum night vision) or a Rolling Code radio control, that can even interact with alarm systems and other access barriers such gates, garage doors, etc, even when already installed. For the more demanding, x1r can also communicate and exchange data with all domotic systems using an I/O card. In developing this new version we have given ample space to design and the appearance of visible accessories in order to avoid altering the door s final appearance and make it compatible with normal construction standards. The result is that all electronic access controls have been inserted in the same faceplate that is normally used to decorate the cylinder and protect it externally. In the event of a power cut or if any other electrical problem should prevent it from working correctly, no problem: for your safety you can always open and close your home using a traditional mechanical key, which if you wish can accompany you discreetly at all times inside the transponder xkey.

Access controls Transponder reader (TAG) Locks equipped with this electronic system can be opened by simply placing the electronic xkey containing the transponder close to the external faceplate. xkey can be programmed by the end user with two hierarchical levels, master and slave, in order to define the rights attributed to each possessor related to system programming access, to vary the mode of operation, to disable or enable new keys or whatever else. Or only and exclusively to open the lock. A mechanical key can be housed inside the TAG for emergency use. Keypad The insertion of a numeric code (up to a maximum of 8 digits) is processed by the internal electronic board processing unit, and if acknowledged as valid causes the lock to open. Keypad tampering will not allow ill-intentioned people to gain access to your home as the encrypted code is stored in the lock s electronic memory. The standard keypad also has an integrated transponder reader with the same performance as described above. The keypad backlighting, to aid night vision, can be activated by pressing any key. Radio control The radio control is the Rolling Code type, in other words the radio frequency transmitted code changes every time that the control button is pressed. One channel (key) is used to open the lock, and the others can be programmed to control other access ways in the home (a gate, a garage door, etc.) by simply integrating the appropriate control module into the system (see the accessories section on the last page). The user can use radio control as an additional opening system, irrespective of whether it has been equipped with a TAG reader or a keypad. Radio control can only be used when installed with a direct power supply or with rechargeable batteries (installation diagrams 2 and 3). Internal programming logic Used to program the system s performance and mode of operation, but also includes a key for quick opening of the lock from inside the home, a LED light signal and a buzzer for acoustic warnings, including one for the amount of charge left in the batteries. I/O interface card (In & Out) The I/O module is a bidirectional communication interface that can be used with all alarm and domotic systems. It sends a remote signal related to all status warnings originating from the lock (door status, bolt position status, latch status). It also has a dedicated relay enabling operation of the lock to be coordinated with a motor-driven door opening device, and an input for the management of a remote opening button.

Installation diagrams and possible ac EXTERNAL SIDE EXTERNAL SIDE 1 1.2 1 9 1.1 3 1.1 7 8 2 2.1 6 2 2.1 1 INTERNAL SIDE 2 INTERNAL SID Alkaline battery operated model Rechargeable battery operated model 1. lock for application for insertion 1. lock for application 1.1 Door contact (supplied with the lock) 1.2 Remote button cable (supplied with the lock) 2. Battery holder complete with power supply cable 2.1 Set of alkaline batteries 3. Cable gland 4. Pair of faceplates for mechanical control (specify finish) 4.1 Internal faceplate for the cylinder 4.2 External faceplate for the cylinder 4.3 Cylinder guard Ø 46 H 26 mm 5. Internal programming logic faceplate 6. xkey (specify number and type) 1.1 Door contact (supplied with the lock) 1.2 Remote button cable (supplied with the lock) 2. Battery holder complete with power supply cable 2.1 Set of rechargeable batteries 3. Cable gland 4. Pair of faceplates for mechanical control (specify finis 4.1 Internal faceplate for the cylinder 4.2 External faceplate for the cylinder 4.3 Cylinder guard Ø 46 H 26 mm 5. Internal programming logic faceplate 6. xkey (specify number and type) 7. Battery charger 8. Transformer 9. Radio control receiver Access control variations applicable to the system Transponder reader (TAG) Access control variations applicable to th Transponder reader (TAG) Keypad with integrated TAG reader Keypad with integrated TAG reader Radio control

cess control variations EXTERNAL SIDE 4 1.2 3 3.3 3.2 3 1 1.1 8 1.2 3.1 2 5 7 6 6 E 3 INTERNAL SIDE Direct power supply operated model for insertion 1. lock for application for insertion 1.1 Door contact (supplied with the lock) 1.2 Remote button cable (supplied with the lock) h) 2. Cable gland 3. Pair of faceplates for mechanical control (specify finish) 3.1 Internal faceplate for the cylinder 3.2 External faceplate for the cylinder 3.3 Cylinder guard Ø 46 H 26 mm 4. Internal programming logic faceplate 5. Power supply unit 6. xkey (specify number and type) 7. I/O logic 8. Radio control receiver e system Access control variations applicable to the system Business logic for radio frequency control of access ways Transponder reader (TAG) Business logic for radio frequency control of access ways Keypad with integrated TAG reader I/O Logic Radio control

Synua Door OIKOS production

The range and the accessories Bolt variations Parts supplied Code Number Protrusion Centre-line distance 4 3 28 0698.03.28 4 13 37 lock, cylinder support, door contact and 0698.13.28 3 3 28 remote pushbutton cable 0698.03.37 3 13 37 0698.13.37 lock, cylinder support, door contact and 4-28 remote pushbutton cable 0698.00.28 3-37 0698.00.37 Battery holder batteries must be ordered separately 587.00.698.0000 Trasponder xkey only transponder with 0698.0000 mechanical keys 0698.0100 Programming logic metal cover must be ordered 98.PI.0698 separately Transponder reader (TAG) metal cover must be ordered 98.TE.0698 separately Keypad with integrated TAG reader metal cover must be ordered 98.PE.0698 separately polished brass 98.00.XOLV Faceplate polished chrome 98.00.XCRL satin chrome 98.00.XCRS satin chrome 98.00.XBRO Rolling code radio control radio control 587.00.0698.0003 receiver 587.00.0698.0008 Business logic for radio frequency optional for installations 587.00.0698.0006 control of access ways with radio control I/O logic 587.00.0698.0007 Battery charger Input 12 VAC Output 6,5 V 50 ma 582.00.6001.0016 Transformer Input 220 VAC Output 12 V 15 VA 582.00.0698.0000 Set of batteries Alkaline 582.00.6000.0006 rechargeable 582.00.6000.0016 Chrome-plated steel cable gland spring-loaded 8810 6013.0000 Cod. 600.00.0698.0009 FIAM s.r.l. Via Don Fasola, 4-22069 Rovellasca (Co) Italy - Tel. +39 02 96740420 www.fiamserrature.it