Measurement Automation Software for the 8510 Network Analyzer

Similar documents
81110A Pulse Pattern Generator Simulating Distorted Signals for Tolerance Testing

Agilent Electronic Calibration (ECal) Modules for Vector Network Analyzers

Agilent Split Post Dielectric Resonators for Dielectric Measurements of Substrates. Application Note

Agilent Measuring Noninsertable Devices

Agilent Test Solutions for Multiport and Balanced Devices

Agilent 8720 Family Microwave Vector Network Analyzers

Selecting RJ Bandwidth in EZJIT Plus Software

Agilent 8753ET/8753ES Network Analyzers

Agilent N2717A Service Software Performance Verification and Adjustment Software for the Agilent ESA Spectrum Analyzers Product Overview

Agilent E5100A Network Analyzer

Agilent N8973A, N8974A, N8975A NFA Series Noise Figure Analyzers. Data Sheet

Agilent Technologies E8047B Analysis Probe System for the Intel Xeon Processor Family

Agilent E4980A Precision LCR Meter 20 Hz to 2 MHz

Agilent Evolution of Test Automation Using the Built-In VBA with the ENA Series RF Network Analyzers

Agilent 8762/3/4A,B,C Coaxial Switches

Agilent Creating Multi-tone Signals With the N7509A Waveform Generation Toolbox. Application Note

2. The Vector Network Analyzer

Agilent Automotive Power Window Regulator Testing. Application Note

Agilent E6481A OPAS32 Engineering Information Management and Analysis Software Configuration Guide

Loop Bandwidth and Clock Data Recovery (CDR) in Oscilloscope Measurements. Application Note

Agilent GSM/EDGE Base Station Test with the E4406A VSA and ESG-D Series RF Signal Generators Product Overview

Impedance 50 (75 connectors via adapters)

Improving Chromatic Dispersion and PMD Measurement Accuracy

HP 8753E RF Vector Network Analyzer

Agilent Network Analysis Applying the 8510 TRL Calibration for Non-Coaxial Measurements

Agilent PNA Network Analyzers 10 MHz to 110 GHz

Agilent E3830 Series Wide-bandwidth Signal Analyzer Custom Systems 100 MHz Bandwidth Microwave Vector Signal Analysis

Agilent 8757D Scalar Network Analyzer 10 MHz to 110 GHz

Agilent E6832A W-CDMA Calibration Application

Agilent E5063A ENA Series Network Analyzer

HEWLETT PACKARD. HP 8510C Network Analyzer 45 MHz to 110 GHz. Unmatched excellence in microwave network analysis

Applying Error Correction to Network Analyzer Measurements. Application Note Table of Contents. Page

Trace Port Analysis for ARM7-ETM and ARM9-ETM Microprocessors

Vector Network Analyzer Techniques to Measure WR340 Waveguide Windows

The Next Generation in Automated Oscilloscope Test

Agilent EEsof EDA.

Agilent 8509C Lightwave Polarization Analyzer

Agilent PN Extending Vector Signal Analysis to 26.5 GHz with 20 MHz Information Bandwidth

Agilent U2000 Series USB Power Sensors

Agilent U2000 Series USB Power Sensors

Agilent 4338B Milliohm Meter

Microwave Multiplexer Module

One Port Network Analyzer

Agilent PN RF Component Measurements: Amplifier Measurements Using the Agilent 8753 Network Analyzer. Product Note

Agilent 8510C Network Analyzer

Experiments Using the HP8714 RF Network Analyzer

Agilent AN 1316 Optimizing Spectrum Analyzer Amplitude Accuracy

Agilent 8712ET/ES, 8714ET/ES RF Economy Network Analyzers Product Overview. Speed, accuracy, and productivity features, at a price you can afford

RF Network Analyzer Basics

Agilent Television Power Consumption Testing. Application Note

ECE 435 INTRODUCTION TO THE MICROWAVE NETWORK ANALYZER

R3765/67 CG Network Analyzer

Agilent 87421A/87422A Power Supply

802.11ac Power Measurement and Timing Analysis

Agilent Balanced Measurement Example: Differential Amplifiers

Wireless Connectivity Testing

Scalar Network Analysis with the HP 8590 Series Spectrum Analyzers Product Overview

Agilent Specifying Calibration Standards for the Agilent 8510 Network Analyzer

Agilent ENA-L RF Network Analyzers

Spectrum Analyzers And Network Analyzers. The Whats, Whys and Hows...

Agilent AN Improving Throughput in Network Analyzer Applications. Application Note

February 2010 Number Vector Network Analyzer upgrade to SureCAL Power Sensor and RF Components Packages

Technical Datasheet Scalar Network Analyzer Model MHz to 40 GHz

PCI Express Probes for Agilent E2960B PCI Express Analysis Systems

Agilent Testing Push-to-talk Over Cellular. Application Note

Agilent Technologies 3000 Series Oscilloscopes

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

Agilent 10 Hints for Making Better Network Analyzer Measurements. Application Note B

PCI Express 1.0 (2.5 GT/s) Protocol Test

X-Series Signal Analysis. Future-ready instruments Consistent measurement framework Broadest set of applications and software

How to Measure 5 ns Rise/Fall Time on an RF Pulsed Power Amplifier Using the 8990B Peak Power Analyzer

Agilent E7475A GSM Based Drive-Test System Configuration Guide

Agilent Technologies Storage Area Network (SAN) Test System 1730 Series 1, 2 and 4Gb/s Fibre Channel Traffic Generators and Analyzers

Multi-Range Programmable DC Power Supplies 9115 Series

Advanced Test Equipment Rentals ATEC (2832)

High Power Amplifier Measurements Using Agilent s Nonlinear Vector Network Analyzer

USB to VGA Adapter USB2VGAE2. Instruction Manual. USB 2.0 to VGA Multi Monitor External Video Adapter

PRODUCT INFORMATION. Insight+ Uses and Features

Software for Agilent Technologies Vector Series Network Analyzers

Keysight M9485A PXIe Multiport Vector Network Analyzer. Configuration Guide

IR-PRO IR-PRO. Operation Guide. Professional Infrared Code Capture System

Network Analysis. Specifying calibration standards for the HP 8510 network analyzer Product Note A

Agilent P940xA/C Solid State PIN Diode Switches

Agilent Technologies E7475A GSM Drive-Test System Product Overview

Antenna Trainer EAN. Technical Teaching Equipment INTRODUCTION

Agilent EEsof EDA.

HP 8970B Option 020. Service Manual Supplement

PLANAR 304/1 Vector Network Analyzer. Operating Manual

a 1 a 2 2 Port b 2 b 1 Multi-Port Handset Switch S-Parameters Application Note AN20 Seven-Port S-Parameter Definition Introduction Summary:

Creating Datalogging Applications in Microsoft Excel

Agilent E5063A ENA Series Network Analyzer. 100 khz to 4.5/ 8.5/18 GHz

AUTOMATIC NETWORK ANALYZER PROCEDURES FOR 5045 KLYSTRON CAVITIES * J.G. Judkins

Field Calibration Software

Agilent 8590C/E Series Spectrum Analyzers and Accessories Configuration Guide

Utilizing Time Domain (TDR) Test Methods For Maximizing Microwave Board Performance

Agilent U2000 Series USB Power Sensors

DDR Memory Overview, Development Cycle, and Challenges

Agilent BenchVue Software (34840B) Data capture simplified. Click, capture, done. Data Sheet

Communicate with Test Instruments Over LAN Using Visual Basic

Transcription:

Agilent 85161B Measurement Automation Software for the 8510 Network Analyzer Product Note Discontinued Product Information For Support Reference Only Information herein, may refer to products/services no longer supported. We regret any inconvenience caused by obsolete information. For the latest information on Agilent s test and measurement products go to: www.agilent.com/find/products In the US, call Agilent Technologies at 1-800-829-4444 (any weekday between 8am 5pm in any U.S. time zone) World-wide Agilent sales office contact information is available at: www.agilent.com/find/contactus This product note provides useful information about the 85161B measurement automation software, including hardware and software requirements, and information that may be useful for specialized uses and advanced applications. The software itself is designed to be self-contained and self-explanatory, and the best way to learn how to use the software is to use it. Try out its features, test its capabilities. Except for specialized applications, a manual is not necessary, and creative experimentation is the best and fastest way to learn.

The manual supplied with the 85161B measurement automation software has eight chapters, three appendices, and a complete alphabetical index. A brief summary of the manual contents follows below. Chapter 1 Product Features describes the main features of the 85161B measurement automation software and explains briefly some of the ways it can be used to make measurements with the 8510 network analyzer. Chapter 2 Hardware and Software Requirements describes the hardware and software required to use the 85161B measurement automation software. The 85161B software is designed to be used with HP 9000 Series 200 or Series 300 computers, or a PC with Windows that runs HP Basic for Windows. It can be used with 8510 network analyzers, with any 8510-system S-parameter test set, and with either the 8360 synthesized sweeper, the 8340A/B or 8341B synthesized sweeper, or the 8350B sweep oscillator. It can also be used with the 85106 millimeter-wave network analyzer system. The software is written in BASIC, and BASIC 3.0 (or higher) and a number of binary fields must be installed in order to use it. Memory and operating system requirements are explained in Chapter 2. Binary files are listed in Chapter 3. Chapter 3 Setting Up a System tells how to set up a device measurement system using the 85161B software and the recommended hardware. Chapter 4 Installing the 85161B Software tells how to install and run the software on an HP 9000 Series 200 or Series 300 computer. It tells how to install the BASIC operating system and binary files required by the 85161B program and how to install the 85161B software itself into flexible-desk, shared resource management (SRM), and hard disk drive systems. Chapter 4 also tells how to make a working copy of the software and how to run the program when it has been stored in an SRM system or onto a hard disk drive. It also explains screen display and keyboard differences between Series 200 and Series 300 computers when the program is run. Chapter 6 Calibrating the System tells how to use the 85161B software in measurement calibration of the 8510 network analyzer. Measurement calibration is done to produce fully error-corrected measurements and the software guides the user step-by-step through this process. Chapter 6 also covers storing and recalling measurement calibrations. Chapter 7 Measuring Devices tells how to measure devices using the 85161B software, including how to add electrical delay to measurements. This chapter also explains how to use the measurement loops available in the 85161B software to make the same or similar measurements more than once without having to configure the measurement each time. Chapter 8 Plotting, Printing, and Storing Data tells how to plot, print, store, and recall measurement data using the 85161B software. Chapter 8 also tells how to use measurement data in computer-aided engineering applications with the MDS (CITIFile), as well as the Touchstone and Super Compact linear circuit simulation programs and how to convert device files from one format to another. Appendix A Principal Screens and User-Definable Functions summarizes information presented in detail elsewhere in the manual. It offers a program flowchart, illustrations of the principal screen displays, and a list of user-defined numerical values and major functions. Appendix B Error Messages lists the error messages that may appear when the program is run and recommends responses to these messages. Appendix C Modifying the Program tells how to customize the software by modifying the program. The 85161B measurement automation software is written in BASIC and is not secured, so it is easy to use as a starting-point for custom-designed automated measurement programs. The Index gives immediate, direct access to detailed information on topics that may come up while the software is actually being used. Chapter 5 Configuring Measurements is the first of four chapters that tells how to use the 85161B measurement automation software. Although these chapters are designed mainly as a reference, they also offer (through examples) a tutorial that explains all of the main features of the software. Chapter 5 begins with an overall view of how measurements are made using the 85161B software. Individual sections in this chapter then explain in detail how to set start and stop frequencies, how to choose the number of points in each measurement sweep, and how to set up other details of the measurement. This chapter also tells how to store and recall measurement configurations. 2

85161B Guided measurements The 85161B Measurement Automation Software offers a simple, menu-driven way of making general-purpose measurements over the entire frequency range of the 8510 network analyzer. Depending on the test set, this range is between 45 MHz and 50 GHz (coaxial), or between 8.2 GHz and 110 GHz (waveguide). The software takes complete control of the network analyzer and leads the user step-by-step through the measurement. In this way, repeatable, high-quality magnitude, phase, and group delay measurements can be made with a minimum of training or previous experience, and with no need to learn the network analyzer front panel. Measurement configuration Measurements are configured using the 85161B configuration screen. This screen makes available the main measurement capabilities of the 8510 network analyzer. Choices can be made before each measurement, or they can be made once and recalled together as a stored configuration. Choices on the 85161B configuration screen make it easy to set or modify all of the following details of the measurement directly, without using or referring to the front panel of the 8510 network analyzer: Start and stop frequencies from 45 MHz to 110 GHz, depending on the test set. If desired, the advanced configuration screen can be used instead to specify frequencies in terms of the center frequency and frequency span or in up to 30 separate (non-continuous) frequency segments or single frequency points. Number of points per data trace: five different choices are available directly, from 51 to 801 points; other choices are available by listing frequency segments. RF source power level, sweep time, and if the source is an 8360 series, 8340A/B or 8341B synthesized sweeperramp or step sweep mode. Port 1 and Port 2 attenuators can be set to increase dynamic range (except for test sets with Option 002 which has no attenuators). Noise reduction through trace averaging can be specified also, using the advanced configuration screen. 3

Calibration for error correction When the desired measurement configuration has been set up, a guided step-by-step measurement calibration sequence begins. The calibration type is chosen in response to the user s answers to questions about the type of calibration that will be done and the kind of device that will be measured: 1-port reflection calibration for one-port devices. One path 2-port calibration for two port devices measured on a reflection/transmission only test set. Full 2-port OSLT (open-short-load-through) or TRL (through-reflect-line) calibration for two-port devices measured on an S-parameter test set. If non-insertable two-port devices will be measured, guided full 2-port calibration is available using either the adapter removal or equal-length-adapter technique. This is also true of transitional devices, in which the input and output ports have different connector types. When the calibration has been chosen, the software guides the user step-by-step through the calibration even if the calibration requires connecting and disconnecting adapters or using a different calibration kit for each test port. If desired, the network analyzer can be calibrated manually using the front panel. The calibration sequence can also be omitted to make measurements immediately, or a calibration that has been done and stored earlier can be recalled and used again. Different calibration (and measurement) interfaces can be specified according to connector type: 7 mm, 3.5 mm, 2.4 mm, 1.85 mm, type-n, or X/P/K/R/Q/U/V/W-bands. Measurement calibration is performed at the actual measurement reference plane, and in the connector type of the device-under-test, regardless of the connector type of the test set. When the device-under-test has SMA connectors, measurement calibration is performed in 3.5mm. When the calibration type and measurement interface have been specified, the software guides the user step-by-step through the calibration process. Screen prompts tell which calibration device to use, and when to connect and disconnect each one. Storing configurations and calibrations Measurement configurations and calibrations can be saved in disk files and recalled whenever needed. These can then be recalled and done in exactly the same way every time, no matter how long or complicated the instructions would be if the tests were performed manually. Plotting and printing data Display and plot options Test data can be displayed (and plotted) in linear or log magnitude, SWR, phase, polar, or Smith Chart formats. Start and stop frequencies different from those in the measured data can be specified to magnify a particular area of interest for closer examination. Both axes are labeled for easy interpretation, and both axes can be scaled manually for optimum data resolution. Print options Measurement data in numerical form can be displayed on the computer or printed on any GPIB compatible printer. Up to nine columns of data can be printed to represent frequency and test data in linear or log magnitude, phase, SWR, or group delay for all four S-parameters. H, Y, or Z parameter conversion is also available. Data storage and CAE applications Device measurement data can be stored on flexible disks in binary format or in formats compatible with the 85161B Measurement Automation Software, as well as the Touchstone or Super Compact linear circuit simulation programs used in computer-aided engineering (CAE). Data that has been stored in binary format can be recalled later for further examination or statistical analysis. Compatibility with well-known circuit simulation programs makes it possible to use actual device data in CAE applications. In addition, files can be converted from one storage format to another, allowing previously measured device data to be moved between CAE programs. When the calibration sequence has been completed, the calibration data can be stored in a calibration file and used either immediately or later. It can also be used immediately without storing it, for one-of-a-kind measurements. 4

Program flowchart (1 of 3) configuring measurements Figure 1. 5

Program flowchart (continued) Figure 2. 6

Program flowchart (continued) Figure 3. 7

Useful Web Reference For the latest component test information, visit our website at: www.agilent.com/find/component_test Agilent Email Updates www.agilent.com/find/emailupdates Get the latest information on the products and applications you select. Agilent Direct www.agilent.com/find/agilentdirect Quickly choose and use your test equipment solutions with confidence. Agilent Open www.agilent.com/find/open Agilent Open simplifies the process of connecting and programming test systems to help engineers design, validate and manufacture electronic products. Agilent offers open connectivity for a broad range of systemready instruments, open industry software, PC-standard I/O and global support, which are combined to more easily integrate test system development. www.agilent.com Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Two concepts underlie Agilent s overall support policy: Our Promise and Your Advantage. Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you receive your new Agilent equipment, we can help verify that it works properly and help with initial product operation. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and onsite education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. United States: Korea: (tel) 800 829 4444 (tel) (080) 769 0800 (fax) 800 829 4433 (fax) (080) 769 0900 Canada: Latin America: (tel) 877 894 4414 (tel) (305) 269 7500 (fax) 800 746 4866 Taiwan: China: (tel) 0800 047 866 (tel) 800 810 0189 (fax) 0800 286 331 (fax) 800 820 2816 Other Asia Pacific Europe: Countries: (tel) 31 20 547 2111 (tel) (65) 6375 8100 Japan: (fax) (65) 6755 0042 (tel) (81) 426 56 7832 Email: tm_ap@agilent.com (fax) (81) 426 56 7840 Contacts revised: 09/26/05 For more information on Agilent Technologies products, applications or services, please contact your local Agilent office. The complete list is available at: www.agilent.com/find/contactus Product specifications and descriptions in this document subject to change without notice. Agilent Technologies, Inc. 2000, 2006 Printed in USA, July 13, 2006 5980-0391E