Quick Reference Guide Mechanical Shearbolt Connectors. te.com/energy

Similar documents
Quick Reference Guide Euro Style Terminal Blocks

SlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version

5.2. Overview. The better method to install solderless compression connectors on power cable

Quick Reference Guide AMP CT Connector Series

Tape Wound, Split Core and Ebony Current Transformers

Storage Area Management (SAM) Clutter-Free, Super-Efficient Network Infrastructure Management

How To Terminate Copper Magnet Wire On Aluminum Wire

PPS-PPQ-BT-PIAS RESIN INSULATORS FOR OIL INSULATED ELECTRICAL MACHINES

Tape Wound, Split Core and Ebony Current Transformers

Wireless Applications. Host Interfaces. te.com/products/ngff. TE Connectivity. M.2 (NGFF) Connector. Ultrabook/ Notebook. Smart TV. Server.

DL AND DBA SERIES CONNECTORS QUALIFIED TO MIL-DTL SERIES III Weight-saving aluminum connectors designed for rugged use and high temperatures

369 SERIES CONNECTORS

How To Build A Powerline Box Powerline Generator

Connection Solutions

INTO THE INEVITABLE. CONVERTING THE POTENTIAL ELECTRIC VEHICLE & INFRASTRUCTURE EVERY CONNECTION COUNTS

Takfan Machinery and Mould Co Ltd. Plug in Bushing. LV Monoblock. RMU Bushing. 4 Way CT Terminal.

Bolted Connectors & Terminals

Quick Reference Guide Micro USB Connectors

Infrastructure for the next three generations

Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series

Quick Reference Guide 1.5 mm AMP Mini CT Connector Series

Copper and Aluminum busbars

M8 / M12 CONNECTOR SYSTEM

AMP Standard Terminals and Splices. RoHS. Ready

ScottishPower Distribution Cables & Equipment. Metal Theft

The Quality Connection. BETAflam Fire Resistant Safety Cables

Important Information: Complete Terms and Conditions are printed on sales invoices

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

KOLMA and IHDA Indoor type Cable Current Transformers Catalogue ABB Power Distribution ABB Transmit 1 KKOLMA 1 GB

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

FLEXIBLE COPPER & ALUMINIUM CONNECTIONS. Product Range 1 VGL - ALLIED CONNECTORS

HEAT SHRINK RAYCHEM PRODUCT TECHNOLOGY A PROVEN TRACK RECORD OF SOLVING THE WORLD S HARSHEST CHALLENGES

Power cable compression lugs Installation of solderless compression lugs on power cables

Gas Discharge Tubes GTCX26-XXXM-R05 Series

Specialist Electrical Distributor [ ]

Quick Reference Guide High Speed Input/Output Solutions

Directory chapter 04

Installation. Smart-UPS VT MGE Galaxy Maintenance Bypass Panel kva 400 V

SUPERSEDED REVISION. Gas Discharge Tubes GTCX28-XXXM-R20 Series. Features: Benefits: Applications

Gas Discharge Tubes GTCX36-XXXM-R05 Series

SMD High Power Precision Resistors

Powermate Range Pitch 7.62

<< Previous Page Next Page >>

Raychem Custom Multicore (Multiconductor) Cables

RE-ENTERABLE SPLICE CLOSURE KITS. (For Air Core None Pressurized Cable)

Quick Reference Guide 1.5 mm AMP Mini CT Connector Series

VDE Information. Degree of Pollution, Clearances and Creepage Distances and Insulating Materials

OUTDOOR DISCONNECTORS A division of ACTOM (Pty) Ltd

SECTION DRY-TYPE TRANSFORMERS

White paper. SACE Tmax XT Circuit-Breaker Terminals and Connection

Specification for Cable Accessories, Termination and Jointing Materials for Underground Electrical Power Cables for Nominal System Voltage Up to 33kV

Gulf Cable & Electrical Ind. Co.

COAXICON Contacts. RF Coax Connectors. Product Facts

ASSEMBLY INSTRUCTIONS Residential Roof solutions

Gas Discharge Tubes GTCX38-XXXM-R10 Series

3M Quick Connect System (QCS) 2814

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

Figure 1 (end) Updated document to corporate requirements Added text to Paragraph 2.4

PC/104, PC/104 -Plus, VarPol connectors

INCORPORATING WEIGHT-SAVING TECHNOLOGY IN AEROSPACE APPLICATIONS: AT WHAT RISK?

VIPERFLEX ELECTRIC CABLE

NTC Thermistors, Mini Lug Sensors

HarnWare V6 Computer-Aided Electrical Wiring Harness Design Software

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

Network Standard Advice No. 1420C 9/6/2011

Upgrading a GainMaker Line Extender from a Line-Powered Source to a 120 V AC-Powered Source Installation Instructions

3M Mini D Ribbon (MDR) Connectors.050 Surface Mount Right Angle Receptacle - Shielded 102 Series

a Nexans company Catalogue 2013

08. SEK IDC CONNECTORS

Transformer Bushings for GIS

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Product Overview 2Pro AC Devices Provide Overcurrent/ Overvoltage/Overtemperature Protection for AC Industrial and Appliance Applications

Universal MATE-N-LOK Connectors

Faster Method for Connecting Customers in the Colocation Data Center

Termination solutions Easily and reliably connect your wires

Standard Buccaneer - Ethernet

400 Series Buccaneer BUCCANEER POWER. bulgin

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Temperature Sensors. Accessories. for Injection Molding. Types 6192B, 6193B,

e-mobility Special cables for electric vehicles Coroplast Fritz Müller GmbH & Co. KG Tapes Cables Cable Assemblies

The range of rail-mounted terminal blocks. for a perfect electrical installation.

Copper wire figures. AWG Table

5SV Residual Current Protective Devices

Mounting instructions for SOT78 (TO-220AB); SOT186A (TO-220F)

Canopy Surge. User Manual

Airdac CNE and SNE, 600/1000V, Polyethylene Sheath, SANS 1507, NRS 063 & NRS 017

MiCAFIL. 1 RIP Technology. Bushings. Z. Zic 09/2003

FASTON Terminals and Connectors

Elo Touch Solutions Wall-mounting Kit for the 5501L IDS Touchmonitors

AMF112 Instruction Manual

The complete guide to Low Voltage switchgear

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

CABLES FOR PHOTOVOLTAIC SOLAR ENERGY INSTALLATIONS FOR CLEAN ENERGY

Medium Voltage Terminations, 5 kv 46 kv

Type RP73 Series. SMD High Power Precision Resistors. Key Features. Applications. Characteristics - Electrical - RP73 Series - Standard

6000 Series Buccaneer

HUS-HR Stainless steel Concrete Screw A CE conformity. Corrosion resistance. European Technical Approval

Premolded cable termination, indoors SOT 7.2 kv

Transcription:

Quick Guide Mechanical Shearbolt Connectors te.com/energy

Contents Bi-Metal Connectors BLMT Mechanical Lugs BLMC Mechanical Lugs - Centre Palm 6 VCXI Bolted Lugs 8 BSMB Mechanical Links 9 BSMV Mechanical Split Connectors 11 899 Bolted Connectors 12 89 Bolted Connectors - Brass Screws 1 HEL Bolted Connectors - Removable Screws 1 BLSB Bolted Connectors - Sector Shaped 15 HVBRM Underground Medium Voltage Branch Joint Connectors 16 uminium Connectors LVET Low Voltage End Terminations 17 UST Underground Low Voltage Straight Connectors 18 UBR Underground Low Voltage Branch Joint Connectors 19 UBRD Underground Low Voltage Double Branch Joint Connectors 20 Copper Connectors BET Underground Brass End Terminations 21 BTC Brass Tunnel Connectors 22 BCNE Underground Connectors for Waveform 2 te.com/energy Page

Mechanical Lugs blmt Cable Range: Installation Tool: Termination Indoor and Outdoor uminium and Copper Conductors Low and Medium Voltage up to 2kV High Tensile, Tin Plated uminium loy uminium loy / Multi Shear Refer to tables IT-1000-0-AU Sector Stranded Core Sector Solid Core Sector Stranded Core Sector Solid Core Stud Size LB Dimensions Contact Bolts Head size L1 L2 D1 D2 Quantity AF BLMT-25/95-1 M12 60 0 2 12.8 1 1 BLMT-25/95-17 M16 60 0 2 12.8 1 1 BLMT-5/150-1 M12 86 8 28 15.8 1 17 BLMT-5/150-17 M16 86 8 28 15.8 1 17 BLMT-95/20-1 M12 112 60 20 2 19 BLMT-95/20-17 M16 112 60 20 2 19 BLMT-120/00-1 M12 115 65 7 2 2 22 BLMT-120/00-17 M16 115 65 7 2 2 22 BLMT-185/00-1 M12 17 80 2 25.5 22 BLMT-185/00-17 M16 17 80 2 25.5 22 BLMT-185/00-21 M20 17 80 2 25.5 22 BLMT-500/60-1 M12 150 95 50 27 BLMT-500/60-17 M16 150 95 50 27 BLMT-500/60-21 M20 150 95 50 27 AF LB L1 L2 D2 D1 te.com/energy Page

Application Range Conductor Type BLMT-25/95-XX 25 95 25 95 25 70-16 95 10 50 25 70 - - 95* - - - 95* 5.7 12.5 5.5 11.0 -.8 12.5.6 8.0 - BLMT-5/150-XX 5 150 5 150 50 95 50 120 5 150 5 50 50 95 - - 120* 150* - - - 120* 150* 6.8 15.0 6.5 1.0 - - 6.6 15.0 6.5 8.0 - BLMT-95/20-XX 95-20 95-20 95-150 95-150 95-20 95-150 - - 185* - 20* 185 (90 ) - - - 11.0 19.2 10.5 18.0 - - - 11.0 19.2 - BLMT-120/00-XX 120 00 150 00 120 185 120 20 120 00 120 185 - - 20* 00* - - - - 12.7 2.1 12.9 19.8 - - - 12.7 22.6 - BLMT-185/00-XX 185 00 185 00 185 20 185 20 185 00 185 20 - - 00* 00* 00 (90 ) - 27 15.5 2.6 1.8 2.6 - - 15.5 2.6 - - BLMT-500/60-XX 500 60 500 60 - - 500 60 - - - - - - - - - * pressed round 25. 2.5 2.0 28.6 - - 25. 2.5 - - te.com/energy Page 5

Mechanical Lugs Centre Palm blmc Cable Range: Installation Tool: uminium and Copper Conductors for Switchgear Low and Medium Voltage up to 2kV High Tensile, Tin Plated uminium loy uminium loy Refer to tables IT-1000-0-AU Sector Stranded Core Sector Solid Core Sector Stranded Core Sector Solid Core Stud Size LB Dimensions Contact Bolts Head size L1 L2 D1 D2 Quantity AF BLMC-25/95-16-800A M16 77.5 1.5 29 16. 1 12 BLMC-95/20-16-800A M16 107.5 61.5.5 19.5 2 18 BLMC-500/60-16-1250A M16 155 100 50 27 BLMC-800-16-1250A M16 185 10 6 56 27 LB AF L2 L1 D2 D1 te.com/energy Page 6

Application Range Conductor Type BLMC-25/95-16-800A BLMC-95/20-16-800A BLMC-500/60-16-1250A BLMC-800-16-1250A * pressed round 25-95 16-95 25-70 - 16-95 10-50 25-70 - - 95* - - - 95* 5.6-12.5.1-11 - -.8-12.5.6-8 - 95-20 95-20 95-150 95-150 95-20 - 95-150 - - 185* - 50* 185 (90 ) - - - 11.0 19.2 10.5 18.0 - - - 11.0 19.2-500 - 60 500-60 - - 500-60 - - - - - - - - - 25. - 2.5 2-28. - - 25. - 2.5 - - 800 800 - - - 800 - - - - - - - - 2.5-5. 0.9-2.1 - - - 2.5-5. - Mechanical Connectors Installation Easy and secure installation l it takes to tighten bolts is a wrench and hexagon socket, or an installation tool is available Same cut-back length for each type Inserts are included Shear head bolts with predetermined torque ensure a reliable and secure contact The use of a support tool is recommended to prevent conductor bending Separate installation instructions included with every connector or cable lug Installation Tool: IT-1000-0-AU Holding Tool: IT-1000-019 te.com/energy Page 7

Bi-Metallic Bolted Lugs vcxi Indoor Busbar Termination of uminium Conductor to Copper Palm Low Voltage up to 1kV Friction Welded uminium Barrel Link to Copper Palm uminium loy Cable Range: 25-500mm 2 Installation Tool: IT-1000-0-AU Cross Section Range Dimensions Contact Bolts Stud Max uminium Copper Size LB L1 B Ø D2 Intensity Head Size Quantity AF VCXI-11 25-70 25-50 M6 0 8 16 160A 1 10 VCXI-1 50-120 50-95 M10 60 10 20 250A 1 10 VCXI-18 95-185 95-120 M10 72 12.5 25 15A 1 1 VCXI-22 150-00 150-185 M12 89 15.5 1 00A 1 1 VCXI-29 20-500 20 M16 105 20 0 60A 1 1 AF L1 LB B D2 te.com/energy Page 8

Mechanical Links BSMB Cable Range: Installation Tool: Indoor and Outdoor uminium and Copper Conductors Low and Medium Voltage up to 2kV High Tensile, Tin Plated uminium loy uminium loy Refer to tables IT-1000-0-AU Sector Stranded Core Sector Solid Core Sector Stranded Core Sector Solid Core Barrier Dimensions Contact Bolts Head Size AF L1 L2 D1 D2 Quantity BSMB-10/5 yes 5 20 19 8.5 2 10 BSM-25/95 yes 65 0 2 12.8 2 1 BSM-25/95-U no 65 2 12.8 2 1 BSMB-5/150 yes 80 5 28 15.8 2 17 BSMU-5/150 no 80 28 15.8 2 17 BSM-95/20 yes 125 60 20.0 19 BSM-95/20-U no 125 20.0 19 BSMB-95/20- yes 125 60 22.0 19 BSMB-120/00 yes 10 65 7 2.0 22 BSMU-120/00 no 10 7 2.0 22 BSM-185/00 yes 170 80 2 25.5 6 22 BSM-185/00-U no 170 2 25.5 6 22 BSMB-500 yes 190 90 6 0.0 6 27 BSMU-500 no 190-6 0.0 6 27 BSMB-60 yes 200 95 50.0 6 27 BSMB-800 yes 270 10 56 6.0 8 27 BSMB-1000 yes 180 86 60 0.0 8 1 If links are to be used in 6.6 up to kv applications, TE Connectivity need to be consulted to check suitability before jointing. Failure to consult TE Connectivity will void connector warranty. AF L2 L1 L2 D2 D1 te.com/energy Page 9

BSM-10/5 BSM-25/95 BSM-25/95-U BSMB-5/150 BSMU-5/150 BSM-95/20 BSM-95/20-U BSMB-95/20- BSMB-120/00 BSMU-120/00 Application Range Conductor Type 10-5 10-50 10-25 - 10-5 10-5 10-25 - - 5* - - - 5*.7-7.5. - 7.8 - -.7-7.5. - 6.7-25 - 95 25-95 25-70 - 16-95 10-50 25-70 - - 95* - - - 95* 5.7-12.5 5.5-11.0 - -.8-12.5.6-8.0-5 - 150 5-150 50-95 50-120 5-150 5-50 50-95 - - 120* - 150* - - - 120* - 150* 6.8-15.0 6.5-1.0 - - 6.6-15.0 6.5-8.0-95 - 20 95-20 95-150 95-150 95-20 - 95-150 - - 185-20* 185 (90 ) - - 185-20* 11.0-20.8 10.5-18.0 - - 11.0-19.2 - - 95-20 95-20 95-150 95-185 95-20 - 95-150 - - 185* - 20* - - - 185* - 20* 11.0-20.8 10.5-18.0 - - 11.0-19.2 - - 120-00 150-00 120-185 120-20 120-00 - 120-185 - - 20-00* - - - 20-00* 12.7-2.1 12.9-19.8 - - 12.7-22.6 - - BSM-185/00 BSM-185/00-U 185-00 185-00 185-20 185-20 185-00 - 185-20 - - 00-00 00 (90 ) - - 00-00 15.5-2.6 1.8-2.6 - - 15.5-2.6 - - BSMB-500 BSMU-500 500 500 - - 500 - - 25. - 28.9 2.0-25.1 - - 25. - 28.6 - - BSMB-60 BSMB-800 BSMB-1000 * pressed round 60 60 - - 60 - - 28.7-2.5 27. - 28. - - 28.7-2.5 - - 800 800 - - 800 - - 2.5-5. 0.9-2.1 - - 2.5-5. - - 1000 1000 - - 1000 - - 7-9.5.8-6 - - 7-9.5 - - te.com/energy Page 10

Mechanical Split Connectors BSMV Indoor and Outdoor uminium and Copper Conductors Low and Medium Voltage up to 2kV High Tensile, Tin Plated uminium loy uminium loy Cable Range: 120-00mm 2 Installation Tool: IT-1000-0-AU Sector Stranded Core Sector Solid Core Sector Stranded Core Sector Solid Core Barrier Dimensions Contact Bolts Contact Bolts L1 L2 D1 D2 Quantity Head size AF Quantity Head size AF2 BSMV-120/00 yes 160 65 7 2 22 1 21 BSMV-185/00 yes 190 80 2 25.5 6 22 1 19 Application Range Conductor Type BSMV-120/00 BSMV-185/00 * pressed round 120-00 150-00 120-185 120-20 120-00 - 120-185 - - 20* - 00* - - - 20* - 00* 12.7-2.1 12.9-19.8 - - 12.7-22.6 - - 185-00 185-00 185-20 185-20 185-00 - 185-20 - - 00* - 00* 00 (90 ) - - 00* - 00* 15.5-2.6 1.8-2.6 - - 15.5-2.6 - - If links are to be used in 6.6 up to kv applications, TE Connectivity need to be consulted to check suitability before jointing. Failure to consult TE Connectivity will void connector warranty. AF2 AF1 L2 L1 L2 D2 D1 te.com/energy Page 11

Bolted Connectors 899 Indoor and Outdoor uminium and Copper Conductors Low Voltage up to 1kV High Strength, Tin Plated uminium loy, Corrosion Resistant Uncoated uminium Cable Range: -50mm 2 Installation Tool: IT-1000-0-AU Sector Stranded Core Sector Solid Core Sector Stranded Core Sector Solid Core Barrier Sector Stranded Cross Section Range Dimensions Set Screws Sector Solid Round Stranded Round Solid d l Quantity Wrench Size HEL-899-Z-AK no 50 5 50 5 16 0 2 10 te.com/energy Page 12

Bolted Connectors - Brass Screws 89 Indoor and Outdoor uminium and Copper Conductors Low Voltage up to 1kV High Strength, Tin Plated uminium loy, Corrosion Resistant Electro-Tinned Brass Cable Range: -185mm 2 Installation Tool: IT-1000-0-AU Sector Stranded Core Sector Solid Core Sector Stranded Core Sector Solid Core Barrier Sector Stranded Cross Section Range Dimensions Set Screws Sector Solid Round Stranded Round Solid d l Quantity Wrench Size HEL-897-Z-AK no - 5-50 - 5-50 16 0 2 HEL-6897-Z-AAK no 10-50 10-50 10-50 10-50 18 0 2 /10 HEL-887-Z-AK no 25-70 5-95 16-70 16-95 25 55 2 5 HEL-888-Z-AK no 25-185 5-185 5-185 10-95 2 80 2 6 HEL-6888-Z-AK no 5-120 50-150 5-150 50-95 28 75 2 6 te.com/energy Page 1

Bolted Connectors - Removable Screws hel Indoor and Outdoor uminium and Copper Conductors Low Voltage up to 1kV High Strength, Tin Plated uminium loy, Corrosion Resistant Electro-Tinned Brass Cable Range: 25-20mm 2 Installation Tool: IT-1000-0-AU Sector Stranded Core Sector Solid Core Sector Stranded Core Sector Solid Core Barrier Sector Stranded Cross Section Range Dimensions Set Screws Sector Solid Round Stranded Round Solid d l Quantity Wrench Size HEL-6988-T-Z-AK-AS yes 120-185 + 20* 120-20 120-20 120-20 8 128 6 HEL-968-Z-AK no 25-185 5-185 5-185 10-95 CU 16-185 AL 2 108 6 * Stranded -shaped conductor 20 mm2 has to be rounded. te.com/energy Page 1

Bolted Connectors - Sector Shaped bslb Underground uminium and Copper Conductors Low Voltage up to 1kV High Strength, Tin Plated uminium loy uminium loy Cable Range: 6-150mm 2 Installation Tool: IT-1000-0-AU Sector Stranded Core Sector Solid Core Sector Stranded Core Sector Solid Core Barrier Dimensions Contact Bolts Head size AF L1 L2 D1 D2 Quantity BSLB-25/150-S-AS yes 70 5 28 20.5 2 1 BSLB-25/150-S-AS Cross-section range Application Range Conductor Type Contact Bolts Qty Head size AF2 25-95 25-95 25-150 25-150 - - 25-150 2 1 AF L2 L2 D2 L1 D1 te.com/energy Page 15

Underground MV Branch Joint Connectors hvbrm Medium Voltage Branch Joint for uminium and Copper Conductors Medium Voltage up to 2kV uminium loy - Brass gauze may be used for copper conductors Brass range taking Cable Range: 25-00mm 2 Installation Tool: IT-1000-0-AU Type Stud Size Cross Section Range Dimensions L W D H I HVBRM18SOUTC Solid blocked M18 25-185 15 61 1 5 62 HVBRM18SPUCT Split blocked M18 25-185 15 61 1 5 62 HVBRM22SOUTC Solid blocked M20 25-00 15 77 6 2 62 HVBRM22SPUCT Split blocked M20 25-00 15 77 6 2 62 If links are to be used in 6.6 up to kv applications, TE Connectivity need to be consulted to check suitability before jointing. Failure to consult TE Connectivity will void connector warranty. te.com/energy Page 16

uminium Mechanical Connectors End Terminations lvet Termination of uminium & Core Solid Conductors Low Voltage up to 1kV Cast uminium Brass Cable Range: 90-00mm 2 Installation Tool: IT-1000-0-AU Sector Solid Core Sector Solid Core Stud Size Cross Section Range Dimensions L I D W Socket Size (A/F) LVET120-12 M12 90-120 86 0 28 2 1 LVET120-16 M16 90-120 86 0 28 2 1 LVET185-12 M12 120-185 10 56 5 9 19 LVET185-16 M16 120-185 10 56 5 9 19 LVET20-12-UTB M12 20 98 8 2 2 1 LVET120-12 M12 90-120 86 0 28 2 1 LVET00-12-UTB M12 00 116 56 19 LVET00-16 M16 20-00 116 56 1 19 te.com/energy Page 17

uminium Mechanical Connectors Underground LV Straight Connectors UST Underground uminium Conductors Low Voltage up to 1kV uminium loy uminium loy Cable Range: 5-00mm 2 Installation Tool: IT-1000-0-AU Sector Stranded Core Sector Solid Core With Shroud Barrier Conductor Size Range Dimensions L H W Socket Size (A/F) UST95 UST95INS no 5-95 80 27 26 1 UST185 UST185INS no 5-185 108 5 19 UST00 UST00INS no 70-00 108 8 1 19 The moulded orange shrouds offer reliable and robust insulation reducing installation time and making live working easier. Breather holes on the shroud allow 2 and part resins to flow freely and encapsulate the connector and shroud assembly te.com/energy Page 18

uminium Mechanical Connectors Underground Universal LV Branch Joint UBR Transition between Different uminium Conductors Low Voltage up to 1kV uminium loy Refer to table Cable Range: 5-00mm 2 Installation Tool: IT-1000-0-AU Sector Stranded Core Sector Solid Core Sector Stranded Core Sector Solid Core With Shroud Barrier Conductor Size Range Dimensions L H W Bolt Material Socket Size (A/F) UBR95 UBR95INS no 5-95 0 8 50 uminium loy 1 UBR185 UBR185INS no 5-185 5 7 67 uminium loy 19 UBR00 UBR00INS no 70-00 5 5 78 uminium loy 19 UBR00 - no 185-00 5 62 78 Brass 19 The moulded orange shrouds offer reliable and robust insulation reducing installation time and making live working easier. Breather holes on the shroud allow 2 and part resins to flow freely and encapsulate the connector and shroud assembly. te.com/energy Page 19

uminium Mechanical Connectors Underground Universal LV Double Branch UBRD Transition Where Two Cables are Jointed at the Main Low Voltage up to 1kV uminium loy uminium loy Cable Range: 5-00mm 2 Installation Tool: IT-1000-0-AU Sector Stranded Core Sector Solid Core Sector Stranded Core Sector Solid Core Conductor Size Range Dimensions L H W Socket Size (A/F) UBRD95 5-95 80 8 50 1 UBRD185 5-185 108 7 67 19 UBRD00 70-00 108 5 78 19 te.com/energy Page 20

Copper Mechanical Connectors Underground Brass End Terminations BET Copper Stranded or Solid Conductors Brass Brass Cable Range: 10-120mm 2 Installation Tool: IT-1000-0-AU Stud Size Max Conductor Size Dimensions L I W Installation Type BET5-12 M12 5 55 25 20 mm len BET60-12 M12 60 70 25 1mm Socket BET120-12 M12 120 86 6 28 16mm Socket BET5-16 M16 5 55 25 20 mm len BET60-16 M16 60 70 25 1mm Socket BET120-16 M16 120 86 6 28 16mm Socket te.com/energy Page 21

Copper Mechanical Connectors Brass Tunnel Connectors btc Copper Stranded Conductors Low Voltage up to 1kV Brass Brass Cable Range: 10-70mm 2 Installation Tool: IT-1000-0-AU Barrier Stud Size Conductor Range Rifled Bore Nominal Diameter BTC--0T no M6 10-5 8 BTC--5W yes M6 10-5 8 BTC-5-50T no M8 10-50 10 BTC-5-55W yes M8 10-50 10 BTC-6-55T no M10 10-70 11 BTC-6-60W yes M10 10-70 11 te.com/energy Page 22

Copper Mechanical Connectors Underground Connectors for Waveform CNE Bcne Combined Neutral and Earth Copper Conductors Low Voltage up to 1kV Brass Brass Cable Range: 10-20mm 2 Installation Tool: IT-1000-0-AU Circular Flexible Total Cross Section Dimensions L H W BCNE-1S 10-125 16 1 0 BCNE-S 125-20 16 50 29 H W L te.com/energy Page 2

About TE Connectivity TE Connectivity is a global, $12.1 billion company that designs and manufactures over 500,000 products that connect and protect the flow of power and data inside the products that touch every aspect of our lives. Our nearly 100,000 employees partner with customers in virtually every industry from consumer electronics, energy and healthcare, to automotive, aerospace and communication networks enabling smarter, faster, better technologies to connect products to possibilities. FOR MORE INFORMATION TE Technical Support Centre NSW: +61 (2) 955 269 QLD: +61 (2) 955 2627 VIC/TAS/SA/NT: +61 () 8562 7966 WA: +61 (8) 958 7805 New Zealand: +6 (9) 6 580 Part numbers in this brochure are RoHS Compliant*, unless marked otherwise. *as defined www.te.com/leadfree te.com 2012 Tyco Electronics Energy Pty Ltd, a TE Connectivity Ltd. Company. l Rights Reserved. EPP-1927-AU-5/12 ENG KK 200 While TE Connectivity (TE) has made every reasonable effort to ensure the accuracy of the information in this catalogue, TE does not guarantee that it is error-free, nor does TE make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE reserves the right to make any adjustments to the information contained herein at any time without notice. TE expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this catalogue are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE for the latest dimensions and design specifications. Raychem, Utilux, TE Connectivity and the TE connectivity (logo) are trademarks. Other logos, product and/or company names might be trademarks of their respective owners.