Miniature Rotary Actuator MRD-S with IndraDrive CS control unit Commissioning

Similar documents
Compensation Unit in X-, Y-, and Z-Direction AGE-S-XYZ

Using the WAGO PROFINET Coupler as Remote I/O with a Siemens S7 PLC

Brake module AX5021. Documentation. Please read this document carefully before installing and commissioning the brake module!

The modular Line and Room Gantry design from SCHUNK

Universal Serial Bus (USB) to DH-485 Interface Converter

MINIMAT-EC-Servo Screwdriver Spindles

Operating Instructions Drill rig DRU160

USER GUIDE. Ethernet Configuration Guide (Lantronix) P/N: Rev 6

Operating instructions. AS-i Profibus gateway AC1411 / AC /00 04/2014

Cisco - Configure the 1721 Router for VLANs Using a Switch Module (WIC-4ESW)

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Remote Connection to a WAGO using a High-Speed Internet connection Application note

PG DRIVES TECHNOLOGY R-NET PROGRAMMER R-NET PROGRAMMING SOFTWARE - DEALER ELECTRONIC MANUAL SK78809/2 SK78809/2 1

Changing Your Cameleon Server IP

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Ethernet Radio Configuration Guide

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

IDDERO HOME SERVER. Quick start guide

Servo drives. Compact converter IndraDrive Cs

CMC III Temperatur-/ Feuchtesensor CMC III Temperature/ Humidity Sensor

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

Amcrest 960H DVR Quick Start Guide

Application Note (Revision A) Original Instructions. Visual C++ Installation

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library. Deleting program block Main [OB1] Copying program blocks

xepi 2 Installation Guide Diagnostic Unit and Configuration Interface Doc. Version 4.0 English

E&P HYDRAULICS Remote control EPRC-01 Level System Camper

QUICKSTORE PORTABLE USB3.0

Intel Active Management Technology with System Defense Feature Quick Start Guide

WinCC Runtime Professional Readme SIMATIC HMI. WinCC V11 SP1. Readme WinCC Runtime Professional. Special considerations for Windows 7.

Remote Operation of R&S Instruments Using Remote Desktop Connection via LAN

ABB Drives. User s Manual. Pulse Encoder Interface Module RTAC-01

Schneider OS-Loader usage via Ethernet or USB.

Accessing EtherNet/IP Network Variables in a WAGO with a ControlLogix PLC Application note

Short Manual Intellect v SP2 module Unipos Contents:

Technical Note. Setting ACS drive IP address automatically with Rockwell BOOTP/DHCP Server. Contents

Configuring Windows 7 64 bit for AutoVISION

IDDERO HCx-KNX TOUCH PANELS. Quick start guide

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

Foreword 1. Bosch Rexroth AG I RE 00853/ Foreword

MAGPOWR Spyder Firmware Update Instruction Manual

Cisco Unified IP Conference Phone 8831 Installation

Quick Start Guide. Cisco Small Business. 200 Series 8-Port Smart Switches

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

PLC Control Unit for a CSM-C Steam Compact Clean Steam Generator

INSTALLATION INSTRUCTIONS

CPU PN/DP: Configuring an ET. 200S as PROFINET IO device SIMATIC. PROFINET CPU PN/DP: Configuring an ET 200S as PROFINET IO device

JUSTOP Smart TV Player With Android 4.0. User Manual

Product Information. Gateway For Connecting EnDat Encoders to PROFIBUS-DP

How to read this guide

Installation & Operations Manual

User Manual Revision English

STAR Linear Bushings and Shafts Supplement RE / Linear Motion and Assembly Technologies

Network Time Accessories LED CLOCK. (for NTP Synchronization)

JDSU PathTrak. HCU200 Install User s Guide

Quick Setup Guide High Power Wireless Ethernet Converter WLI-TX4-G54HP

Foglight Experience Monitor and Foglight Experience Viewer

Overview 1. Document Objectives 1. Document Organization 1. Preparation before VIP-280/VIP-320 administration 1

Quick Start Guide. Cisco Small Business. 300 Series Managed Switches

Tina 2A/B Adaptor unit

Hypercom Key Loading and Management (HKLM) RS232 PPP Key Injection PC Setup Guide

Operation Manual. Model : Compact THC Controller SD. ( Step / Dir PID generator) A new generation height controller of plasma torach

Connecting the DG-102S VoIP Gateway to your network

SLC 5/05 Processors Firmware/Operating System ControlFLASH Upgrade

SYNCHRONIZE DIGITAL CLOCK SYSTEM NETWORK DIGITAL CLOCK VER 1.0 DYNATEK

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

User Manual Revision English

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

Contents. ST9612 Model WIC Printer. Get the original printer s information. Edited 11/04/15

Manual TC3 PLC HMI. TwinCAT 3. Version: Date: Order No.: TF1800

Integration of DTV Recorder Generator DVRG into a TCP/IP Network

Windows XP Home Edition / Windows XP Professional

Mounting Instructions. Torque Transducer. A en

Configuring an A Series LED Sign Controller for your Network

Quick Start Guide. Cisco SPA232D Mobility Enhanced ATA

Addendum to the Operating Instructions

user manual IH-W350DB IH-W351DW MyLife webcam pro 5.0 megapixel max resolution

R&S AFQ100A, R&S AFQ100B I/Q Modulation Generator Supplement

Getting Started - SINAMICS Startdrive. Startdrive. SINAMICS Getting Started - SINAMICS Startdrive. Introduction 1

VKD4net Internet. Figure 1. The VKD4net mode of operation

Communication Interface for SMA Inverters SMA BLUETOOTH PIGGY-BACK

Connecting to a Soundweb TM. London Network

5. Tutorial. Starting FlashCut CNC

Business Audio System: Music & Messaging MP3 Player. by Grace Digital Audio. User Guide. Model No. GDI-USBM10

Training Document for Comprehensive Automation Solutions Totally Integrated Automation (T I A) MODULE A5 Programming the CPU 314C-2DP

WAGO PFC 750-8xx Interface to Horner HMI Application note

LED MOTION ACTIVATED FLOOD LIGHT

How To Use Mview On A Powerline 2.2 (Powerline) On A Pc Or Macbook 2 (Powerplst) On An Iphone Or Ipa 2 (Aldo) On Your Iphon 2 (

Instructions for the installation of drivers and data reading software (TOOLBOX 4) The simple and reliable way to measure radioactivity.

Interfacing Basler GigE Cameras With Cognex VisionPro 7.2

AXIS 205 Network Camera Quick Installation Guide

Smile 11 AS-i Emergency stop with safe AS-i input node

Original instructions Tina 3A/Aps Adaptor unit

Quick Start Guide. WAP371 Wireless AC/N Dual Radio Access Point with Single Point Setup Quick Start Guide. Cisco Small Business

Application Note: Connecting to a 2500 Series Processor using PLC Workshop

1000-LB. TRAILER JACK OWNER S MANUAL

Hands-On Microsoft Windows Server Chapter 12 Managing System Reliability and Availability

Wireless-N. User Guide. PCI Adapter WMP300N (EU) WIRELESS. Model No.

Point of view HDMI Smart TV dongle Mini RF Keyboard

DisplayPort 2-Port KVM Switch Installation Guide

Transcription:

Miniature Rotary Actuator MRD-S with IndraDrive CS control unit Commissioning 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW Document-last updated: 2010-07

Translation of the original commissioning manual Dear Customer, Congratulations on choosing a SCHUNK product. By choosing SCHUNK, you have opted for the highest precision, top quality and best service. You are going to increase the process reliability of your production and achieve best machining results to the customer's complete satisfaction. SCHUNK products are inspiring. Our detailed assembly and operation manual will support you. Do you have further questions? You may contact us at any time even after purchase. You can reach us directly at the mentioned addresses in the last chapter of these instructions. Kindest Regards, Your SCHUNK GmbH & Co. KG Precision Workholding Systems Bahnhofstr. 106 134 D-74348 Lauffen/Neckar Tel. +49-7133-103-2503 Fax +49-7133-103-2189 automation@de.schunk.com www.schunk.com 2 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW

Table of contents Table of contents 1 About this manual... 4 1.1 Purpose/validity... 4 1.2 Target groups... 4 1.3 Applicable documents... 4 1.4 Symbols in the manual... 5 2 Basic safety notes... 5 2.1 Intended use... 5 2.2 Environmental and operating conditions... 6 2.3 Controlled production... 6 2.3.1 Protective equipment... 6 2.3.2 Constructional changes, attachments, or modifications... 6 2.4 Personnel qualification... 7 2.5 Safety-conscious working... 7 3 Commissioning... 7 3.1 Required equipment... 7 3.2 Commissioning tasks... 8 3.2.1 Loading motor parameters... 10 3.2.2 Starting field bus... 12 3.2.3 Selecting operating mode... 12 3.2.4 Testing measuring system... 13 3.2.5 Control loop monitoring... 14 3.2.6 Connecting drive control unit IndraDrive CS to the power supply... 14 3.2.7 Controller enable (AF)... 15 3.2.8 Mounting the drive... 15 3.2.9 Set the parameters for the software controlled limits... 16 3.2.10 Set the parameters for the position and speed controllers... 17 4 Appendices... 18 4.1 Connection diagram IndraDrive CS... 18 4.2 Designation key of files for motors... 20 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW 3

About this manual 1 About this manual 1.1 Purpose/validity This manual is part of the drive control unit IndraDrive CS and describes the safe and proper start up of an electrically miniature rotary actuator MRDS-CS. This manual is valid only for the module specified on the front page. 1.2 Target groups Target group Manufacturer, operator Skilled personnel, fitter Tab. 1 Task Keep this manual available for the personnel at all times. Require personnel to read and observe this manual and the applicable documents, especially the safety notes and warnings. Read, observe and follow this manual and the applicable documents, especially the safety notes and warnings. 1.3 Applicable documents You can find the following documents on our homepage: Document Catalog Assembly and operating manuals for Rotary Actuators Manual and references for drive control unit IndraDrive CS General terms of business Purpose Technical data or application parameters of the module and information on accessories. The last version is always valid. Detailed information about assembly, adjustment and commissioning of the rotary actuator. Detailed information about assembly, adjustment and commissioning of the drive control unit IndraDrive CS. Including notes on the warranty. Tab. 2 4 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW

Basic safety notes 1.4 Symbols in the manual To give you quick access to information, the following symbols will be used in this manual: Symbol DANGER WARNING CAUTION NOTICE 1. 2. Meaning Dangers for persons. Nonobservance causes death or serious injuries. Dangers for persons. Nonobservance can cause death or serious injuries. Dangers for persons. Nonobservance can cause slight injuries. Information on avoiding material damage. Prerequisite for a handling instruction. Handling instruction, also measures in a warning or note. Step-by-step handling instruction. Observe the order. 3.... < > Menus and menu items Tab. 3 2 Basic safety notes 2.1 Intended use The module is intended for installation in a machine. The requirements of the applicable guidelines must be observed and complied with. The module may be used only in the context of its defined application parameters. Any other use or use exceeding that specified is an infringement of use for intended purpose. The manufacturer bears no liability for damage resulting from such use. 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW 5

Basic safety notes 2.2 Environmental and operating conditions The module may be used only in the context of its defined application parameters (see catalog and applicable documents). Make sure that the environment is free from splash water and vapors as well as from abrasion or processing dust. Excepted are modules that are designed especially for contaminated environments. 2.3 Controlled production The module represents the state of the art and the recognized safety rules at the time of delivery. However, it can present risks if, for example: The module is not used in accordance with its intended purpose. The module is not installed or maintained properly. The EC Machinery Directive, the VDE directives, the safety and accident-prevention regulations valid at the usage site, or the safety and installation notes are not observed. 2.3.1 Protective equipment Provide protective equipment per EC Machinery Directive. 2.3.2 Constructional changes, attachments, or modifications Additional drill holes, threads, or attachments that are not offered as accessories by SCHUNK may be attached only with permission of SCHUNK. 6 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW

2.4 Personnel qualification The assembly, initial commissioning, maintenance, and repair of the drive control unit may be performed only by trained specialist personnel. Every person called upon by the operator to work on the module must have read and understood the complete Assembly and Operating Manual, especially chapter 2 Basic safety note. This applies particularly to occasional personnel such as maintenance personnel. 2.5 Safety-conscious working Avoid any manner of working that may interfere with the function and operational safety of the drive control unit. Observe the safety and accident-prevention regulations valid at the usage site. 3 Commissioning 3.1 Required equipment The following equipment/requirements are necessary for commissioning a drive with IndraDrive CS: a fully installed drive with an IndraDrive CS drive control unit (for connection schematics, see chapter 4.1 ) PC with Ethernet TCP/IP interface IndraWorks operating software (from Version 08Vxx) Ethernet (Patch cable) PC connection cable - IndraDrive (order no. 329 962) Commissioning CD with the motor parameters and the files for parameter selection. 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW 7

3.2 Commissioning tasks DANGER Danger to life due to electric shock! Touching live parts can cause death. Only professional electricians may carry out work on electrical systems and equipment under compliance of the rules for working with electrical systems.. WARNING Risk of injury due to unwanted movement of the system! Activating the Automatic set up of the control circuit command can lead to a crash of the guided slide. Under no circumstances activate the automatic set up of the control circuit for motors. 1. Wire drive control unit IndraDrive to motor and higherorder controller in accordance with the connection schematics. (see Chapter 4, page 18) 2. Create connection between PC and controller. Note The control unit has the IP address 192.168.0.1 (default setting) The PC interface must have a similar IP address, e.g. 192.168.0.11 and the subnet mask must also be identical: 255.255.255.0. 3. Set the controller to Sercos III communication. This is done using the front side panel. 8 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW

Fig. 1 Front Side Panel 3.1 Press the [Enter] key four times. The desired field bus option flashes on the display. 3.2 Use the arrow keys to select Sercos III.. 3.3 Confirm your selection with the [Enter] key.. The display now shows Sercos III and does not flash. 3.4 Switch off the 24V supply and switch it back on again. The controller reboots and Sercos III is activated. To verify: After start-up the display should show P -1 (see Fig. 1). 4. Start IndraWorks DS on PC. Fig. 2 5. Select Ethernet and set the IP address search range. Note Operation of IndraWorks is explained in the help menu of the program. 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW 9

3.2.1 Loading motor parameters 1 In the main window of IndraWorks, select <View> <Project Explorer>. The Project Explorer appears. Fig. 3 Project Explorer 2 Select the project explorer via the overview structure: <IndraDrive> <Motion> data file <Axis>. Fig. 4 Selectingmotor type 3 Select <IndraDrive> with right mouse button and then in the context menu <Parameter handling> <Import>. 10 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW

The dialog box appears Fig. 5 import motor parameters 6. Select file <Motor parameter> under <MRD-S Torque motor> and <IndraDrive> on the commissioning-cd IndraDrive. 7. Select the appropriate motor parameter file. 8. Select the folder of the desired torque motor type in the dialog box. Fig. 6 load motor parameter 9. Select desired motor parameter file in the next dialog box and open it. The motor parameters are loaded. 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW 11

3.2.2 Starting field bus 1. Configure field bus interface in accordance with IndraDrive CS manufacturer documentation and control cabinet documentation. 2. Connect and start field bus. 3. Implement and check the wiring for controller enable, stop, reference switch and limit switch, depending on the field bus interface. 3.2.3 Selecting operating mode WARNING Risk of injury when the machine/system moves unexpectedly! An improperly set operating mode can lead to undesired drive movement. Under no circumstances set the operating modes Torque control or Speed control Activate the drag fault monitoring and configure it sensibly.. Switch the control unit into the operating mode (phase 4). In the standard control display on drive control unit IndraDrive CS BB will be displayed. 12 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW

3.2.4 Testing measuring system 1. In the tree view of the project Explorer, select <IndraDrive> folder <axis>. Fig. 7 checking status 2. Right click <Type of application> and then select <Diagnostics> from the resulting context menu Select <Status>. The window for the <Status> folder will open. 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW 13

3.2.5 Control loop monitoring Fig. 8 control loop monitoring In the tree view of the project Explorer, select <IndraDrive> <Motion> <Axis> <Control> <Axis control> <control loop monitoring>. The dialog box <Control loop monitoring> appears: 3.2.6 Connecting drive control unit IndraDrive CS to the power supply Switch on power at the control switch cabinet (power supply connection 380 V). AB appears on the display of the standard operating field of the drive control unit IndraDrive CS which indicates that the drive control unit IndraDrive CS is connected to the power supply 14 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW

3.2.7 Controller enable (AF) Note The controller enable can be activated with either hardware or software, depending on the field bus system. 1. Activate controller enable (AF). 2. Activate stop. AF appears on the display of the standard operating field of the drive control unit IndraDrive CS. The drive automatically determines the commutation offset (sinus method) via the measuring system. The drive is set on control. 3.2.8 Mounting the drive 1. Mount all moving modules (moving mass). 2. Move drive to the intended position. 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW 15

3.2.9 Set the parameters for the software controlled limits Fig. 9 Travel limits 1. In the tree view of the Project Explorer, select <IndraDrive> <Motion> <Axis> <Travel limits>. The <Travel limits> window will open: 2. Activate the <Position limit monitor> field 3. Activate the <Travel limit switch> field 4. Configure the travel limit values in the window 16 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW

3.2.10 Set the parameters for the position and speed controllers Fig. 10 Axis control settings In the tree view of the Project Explorer, select <IndraDrive> <Motion> <Axis> <Axis control> Select <Axis control settings> The <Axis control settings> window will open 5. Make the fine adjustments for the position and speed controllers. Note Set the parameters as specified in the functional description in the documentation for the Rexroth IndraDrive (chapter <Drive controller>, section <axis control (closed loop mode)>. 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW 17

Appendices 4 Appendices 4.1 Connection diagram IndraDrive CS Fig. 11 Connection diagram IndraDrive CS (Drawing-No. 360218) 18 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW

Appendices Fig. 12 connection diagram IndraDrive CS 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW 19

Appendices 4.2 Designation key of files for motors AAAAA A - BBB - CCC - DDD - EE - F - G - HH - III - JJJ - KKK - LLL - VVV Motor type with size Length in mm Width in mm Height in mm Winding code Standard winding 01 Encoder type LS100 Sin/Cos, 1 Vss, 1 mm period (SIKO) 1 LE100 Sin/Cos, 1 Vss period (SIKO) with reference mark 1 LIDA489 Sin/Cos, 1 Vss, 20 µm period (Heidenhain) 2 LIA22 Sin/Cos, 1 Vss, 20 µm period (NUMERIK) 2 Reserved 3 RS40,5/25/2048 Sin/Cos, 1 Vss, 2048 period/rotation (NUMERIK) 4 RS30/16/1000 Reserved Sin/Cos, 1 Vss, 1000 period/rotation (NUMERIK) 5 6 Shaft type with rotary feed -through 1 Hall sensortype Standard 1 VSS, 120 01 special design 1 1 Vss, 120, without protective resistors 02 special design 2 1 VSS, 90 03 Controller type IndraDrive CS controller EcoDrive IndraDrive CS IDR SCX ECO IDC Control component Advanced Basic ADV BAS Option 1 Encoder HSF / RSF Encoder ENDat / 1Vss / TTL Encoder IndraDyn / Hyperface Encoder 1 Vss EN1 EN2 ENS EC Option 2 Encoder HSF / RSF Encoder ENDat / 1Vss / TTL Encoder IndraDyn / Hyperface EN1 EN2 ENS Version State of delivery Vxx Fig. 13 Designation key of files for motors 20 01/MRD-S IndraDrive CS/Nr. 360219/en/2011-11-24/CW