Section H. Ground Fault Products????? Index. Ground Fault Products. Index

Similar documents
Cable and Cord Reels. Section R. Cable and Cord Reels Index. Index

Datasheet. AC Outlet DIN-Rail Mountable Receptacles

B. Related Sections: 1. Section Raceway and Boxes for Electrical Systems.

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION , PAGE 1 SECTION WIRING DEVICES

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

Fundamentals of Power

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

SUGGESTED SPECIFICATION for Series 185 Service Entrance Rated Automatic Transfer Switches

Protect your home and family with Advanced Technology from Cutler-Hammer

AdvAntAge SerieS Switch-rAted iec Pin And Sleeve

Advantium 2 Plus Alarm

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

PLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL

Generator DoCKInG StatIonS

SWITCH! DESCRIPTION. ENVIRONMENTAL SPECIFICATIONS Operating Temperature: 0 C to +40 C SPECIFICATION SHEET:

Common Electrical Hazards in the Workplace Including Arc Flash. Presented by Ken Cohen, PhD, PE & CIH (Ret.)

Electrical Grounding. Appendix C

Magnum Mobile Generator MMG55 Specifications

Three-Phase Electric Power Distribution for Computer Data Centers

Extension Cord Safety Policy

USA: 866.LAWSON4U ( ) Canada: lawsonproducts.com. Electrical Industrial and Fleet Solutions

Universal MATE-N-LOK Connectors

TSn SERIES Surge Protective Device

Electrical Hazards. Power Tools. Extension Cords

AMPSEAL* Automotive Plug Connector and Header Assembly

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

The Different Types of AC Power Connectors in North America

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Digital input modules

EKOS Cart. Instructions for Use

CAT ATC POWER BREAKER & POWER CASE SWITCH AUTOMATIC TRANSFER SWITCH

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

Utility Distribution Systems

Instruction / Installation Sheet DataComm Electronics WH-KIT Flat Panel TV Cable Organizer Kit with Duplex Power Solution

picomax The Pluggable Connection System

LIEBERT VNSA Installation Sheet

HARTING Ethernet Cabling 8-poles Overview

INDUSTRY WIDE LABOR-MANAGEMENT SAFETY COMMITTEE SAFETY BULLETIN #23

USER GUIDE TURBOCORD TM PORTABLE CHARGER 120V/240V: DUAL VOLTAGE. AeroVironment EV Solutions

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

Title: Grounding and Bonding Rev-01

Arc Fault Circuit Interrupters Frequently Asked Questions

LOXONE 12 Channel Amplifier

Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Cable/Conduit Conversion

What are the basic electrical safety issues and remedies in solar photovoltaic installations?

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

TWIST-LOCK and HUBBELLOCK Devices

The Different Types of AC Power Connectors in North America

General 1-2-Opto-electronics Safety Switches 4-Emergency

PRODUCT GUIDE. SL Medium Voltage IEC Vacuum Contactors

IEC 309 INTERLOCKS NORTH AMERICAN

mpm DIN CONNECTORS

Amphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH

Instructions & Safety Information Models A220-20D and A220-20L Version 2

For Models #6-5001, #6-7501, # & #10-12K1

2a. IEM Indoor Metal Clad Medium Voltage Switchgear 15KV a. Section INDOOR METAL CLAD MEDIUM VOLTAGE SWTICHGEAR (Std.

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

400 Series - Mini USB Buccaneer

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

QuickSpecs. HP 480/277 Volt Solutions. Overview

Mini USB and USB 2.0-IP67 Connector System

IMMS-CCC. IMMS-CCC Hardwire Central Interface. Installation Instructions

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

Cable Plug acc. to DIN EN , Form A

LOW-VOLTAGE TRANSFORMER QUICK START GUIDE PLANNING GUIDE INSTALLATION GUIDE

IEC Connectors. Introduction

Match. GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match UPS. GE Digital Energy.

Operating Instructions. UL325 Compliant Non-monitored

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

pole, 8 A Safety relay. Screw terminal. 35 mm rail (EN 60715) mounting. 2 CO (DPDT) 8/15 250/400 2, /0.65/0.

Relés e Contatores de Estado Sólido SIRIUS

D-13. temporary / mobile power. for harsh & hazardous (classfied) locations. Construction Demolition Maintenance Turnarounds Shutdowns

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Mureva Assembly surface mounted wiring devices

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

WHOLESALE DIRECT INC WEST 65TH STREET

PowlVac Vacuum Integrity Tester

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

VS CONTROL PACK INSTALLATION INSTRUCTIONS

Telephone- and leased line modem for industrial applications TD-36

EVC40 EMERGENCY VOICE COMMUNICATION SYSTEM

The complete range of consumer switchboards and switchgear

CURRENT TRANSFORMER MODEL 546 UL1015 #16 AWG LEAD WIRE, STANDARD LENGTH IS 24" 1 X

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications

ULTIMATE SNAP-N-SEAL

Transcription:

Section H Index Products Page Number Features and Benefits H-2 Heavy Duty Hospital Grade / Heavy Duty Industrial Grade GFCI Receptacles H-3 Commercial Grade GFCI Receptacles H-4 Commercial Hospital Grade GFCI Receptacles H-4 GFCI Plugs H-5 Portable Plug In GFCI Devices H-6 Portable GFCI Line Cords H-7 9 Multi Outlet Portable GFCI H-10 GFCI Module H-10 Hard Wired 30A GFCI H-11 Portable 30A GFCI H-12????? Index www.hubbell-wiring.com

Features and Benefits Features and Benefits Heavy Duty, Hospital Grade, GFCI Duplex Receptacle Impact resistant nylon face for abusive environments. Pretensioned ground contacts for superior ground blade retention. Tandem modified bypass power contacts increase spring characteristics for greater contact forces and lower operating temperatures. Shielded coil for RFI/EMI protection of nuisance tripping. All glass PC board provides superior moisture immunity for longer life in humid environments. Conformal coating on PC board for additional moisture immunity. Feed through protection. Hubbell GFCI receptacles are built for quality, designed for easy installation and packaged for convenience. Multiple grades fulfill every need. Each type of receptacle is built from materials chosen for that particular application and GF8200IA packaged with the required hardware. All Circuit Guard GFCI receptacles are Class A, listed to UL standards 498 and 943 2003 requirements and certified to CSA standard CSA 22.2 No. 144. The operating temperature range is -35 C to +66 C. H-2 www.hubbell-wiring.com

15 and 20 Ampere, 120 Volt AC Straight Blade Heavy Duty, Industrial Specification Grade and Hospital Grade, Duplex Receptacles Heavy Duty Specification Grade GFCI Duplex Receptacles Color Catalog Numbers Flush nylon face, side wired, Brown GF5262A GF5362A multiple drive screws. Ivory GF5262IA GF5362IA Gray GF5262GYA GF5362GYA Red GF5262RA GF5362RA White GF5262WA GF5362WA Circuit Guard Heavy Duty Hospital Grade, GFCI Duplex Receptacles Color Catalog Numbers Flush nylon face, side wired, Brown GF8200A GF8300A multiple drive screws. Ivory GF8200IA GF8300IA Gray GF8200GYA GF8300GYA Red GF8200RA GF8300RA White GF8200WA GF8300WA Notes: GFCI type receptacles should not be used in critical care patient areas or for electrical life support equipment applications because of the possibility of power interruption. All GFCI receptacles listed above are furnished with both the proper color nylon wall plate, and, a S26 302/304 super stainless steel wall plate. 4 to 6 ma. Trip Time.025 sec. nominal. Voltage 120V AC +10% - 15%. Amperage 15A/20A, 20A Feed Thru. Maximum Interrupting Capacity 2000A. -35 C to +66 C or -30 F to +150 F. Maximum Humidity 95%. Listings & Standards Meets UL498 for receptacles, UL943 2003 Class A for GFCIs UL File E41978. CSA Certified. Codes Meets all NEC & CEC requirements. G W NEMA 5-15R 15A 125V UL CSA G W NEMA 5-20R 20A 125V UL CSA 3.28" 2.62" (83.3) (66.5) 3.28" 2.62" (83.3) (66.5) 1.81" (46.0) GF5262A 1.81" (46.0) 1.13" (28 7) 1.13" (28.7) GF8200A Heavy Duty GFCI Receptacles www.hubbell-wiring.com H-3

Commercial GFCI Receptacles 15 and 20 Ampere, 120 Volt AC Straight Blade Commercial Specification Grade and Commercial Hospital Grade GFCI Duplex Receptacles 3.28" 2.62" (83.3) (66.5) 1.66" (42.2) GFR5252IA 1.64" (41.7) GFR5350BK 1.64" (41.7) GF8300HI 1.06" (27.1) 2.75" (69.8) 1.13" (28.7) 2.61" (66.3) 1.13" (28.7) 3.28" (83.3) 3.28" (83.3) 2.61" (66.3) Commercial Specification Grade GFCI Duplex Receptacles Color Catalog Numbers Flush, nylon face, Brown GFR5252A back & side wired, Ivory GFR5252IA multiple drive screws. Gray GFR5252GYA Matching nylon wallplate White GFR5252WA included. Black GFR5252BKA Office White GFR5252OWA Red GFR5252RA Bulk packed, 50 pieces. Brown GFR5252AM1 Ivory GFR5252IAM1 Gray GFR5252GYAM1 White GFR5252WAM1 Black GFR5252BKAM1 Circuit Guard Faceless GFCI Color Catalog Numbers Faceless, back and side wired, Brown - GFR5350 multiple drive screws. Ivory - GFR5350I Matching nylon wallplate White - GFR5350W included. Black - GFR5350BK Circuit Guard Commercial Hospital Grade GFCI Duplex Receptacles Color Catalog Numbers Flush, nylon face, Brown GF8200H GF8300H back and side wired, multiple drive Ivory GF8200HI GF8300HI screws. Matching nylon wallplate Gray GF8200HGY GF8300HGY included. Red GF8200HR GF8300HR White GF8200HW GF8300HW Office White GF8200HOW GF8300HOW Note: GFCI type receptacles should not be used in critical care patient areas or for electrical life support equipment applications because of the possibility of power interruption. 4 to 6 ma. Trip Time.025 sec. nominal. Voltage 120V AC +10% - 15%. Amperage 15A/20A, 20A Feed Thru. Maximum Interrupting Capacity 2000A. -35 C to +66 C or -30 F to +150 F. Maximum Humidity 95%. Listings & Standards Meets UL498 for receptacles, UL943 2003 Class A for GFCIs UL File E41978. CSA Certified. Codes Meets all NEC & CEC requirements. G W NEMA 5-15R 15A 125V UL CSA G W NEMA 5-20R 20A 125V UL CSA GFR5352A GFR5352IA GFR5352GYA GFR5352WA GFR5352BKA GFR5352OWA GFR5352RA GFR5352AM1 GFR5352IAM1 GFR5352GYAM1 GFR5352WAM1 GFR5352BKAM1 H-4 www.hubbell-wiring.com

15 Ampere, 120 Volt AC Straight Blade Portable GFCI Plugs Wired On Industrial Portable GFCI Plug Rating Catalog Numbers GFCI plug, manual set, black. 2 pole, 3 wire grounding, GFP5266C 15A, 125V, NEMA 5-15P. GFCI plug, manual set, yellow. 2 pole, 3 wire grounding, GFP5266CY 15A, 125V, NEMA 5-15P. GFCI plug with 1 foot line cord, 2 pole, 3 wire grounding, GFP1C manual set, yellow, with 15A, 125V, NEMA 5-15P, connector body. NEMA 5-15R. Wired On Commercial Portable GFCI Plug Rating Catalog Numbers GFCI plug, automatic set 2 pole, 3 wire grounding, GFP515A field wireable, black. 15A, 125V, NEMA 5-15P. GFCI plug, manual set 2 pole, 3 wire grounding, GFP515M field wireable, black. 15A, 125V, NEMA 5-15P. 4 to 6 ma. Trip Time.025 sec. nominal. Voltage 120V AC +10% 15%. Incorporates no voltage release feature. Amperage 15A. Maximum Interrupting Capacity 2000A. -35 C to +66 C or -30 F to +150 F. Maximum Humidity 95%. Housing High-impact, UV stabilized rigid PVC. UL 94V-0 flammability classification. Input NEMA 5-15P. Cord Range 16/3 12/3 Type SJ, 18/3 12/3 Type S Cord Type: Length (GFP1C) 14/3 Type SJTW-A (UL), SJTW (CSA); 1 foot; NEMA 5-15R. Power ON Indication Neon indicator light. Listings Meets UL943 2003 Class A Listed, CSA Certified. Codes Meets all NEC and CEC requirements. GFP5266C Series- Dimensions W G NEMA 5-15P 15A 125V UL CSA 0.5 HP GFP515A GFP515- Dimensions GFP5266CY Portable GFCI Products www.hubbell-wiring.com H-5

Portable GFCI Products 15 Ampere, 120 Volt AC Straight Blade Portable Plug-In GFCI Devices and GFCI Tester GFP315A GFT2G Circuit Guard Portable Plug-In GFCI 15A 120V AC Three outlet plug-in. Catalog Number GFP315A GFP315A 4 to 6 ma. Trip Time.025 sec. nominal. Voltage 120V AC +10% - 15%. Incorporates no voltage release feature. Current 15A. Maximum Interrupting Capacity 2000A. -35 C to +66 C or -30 F to +150 F. Maximum Humidity 95%. Housing High-impact ABS. Input NEMA 5-15P. Output 3 NEMA 5-15R. Fault Indication Neon indicator light. Center Screw For optional permanent mounting. Listings & Standards Meets UL498 for receptacles, UL943 2003 Class A for GFCIs UL File E41978, CSA Certified. Codes Meets all NEC & CEC requirements. GFI Tester Rating Catalog Number Ground fault tester. 120V AC GFT2G Designed to measure the trip level of portable or wired-in GFCI s in a range of 2-7mA. Leakage level can be adjusted from 2-7mA. Will measure leakage level in small portable tools and appliances from 1-7mA. Ideal for measuring leakage level of GFCI breakers, GFCI portables and GFCI receptacles. H-6 www.hubbell-wiring.com

Features and Benefits Straight Blade Automatic and Manual Set Portable GFCI Line Cords Manual Set GFCI Line Cord All glass circuit board provides superior moisture immunity. High impact UV stabilized housing resists dust, sunlight and chemicals for long life. Heavy-duty molded plug and connector for reliable connection. One-piece flush sealed keypads for greater reliability and resistance to damage due to impact. Solid (not formed) plug blades are crimped and soldered for a better connection and longer life. Bright fault indicator light provides fault confirmation from a distance. Watertight GFCI housing for use in harsh environments. Heavy-duty molded strain relief prevents conductor strain and resulting failure. Available in Manual or Automatic Set. Portable GFCI Line Cords provide ground fault protection both indoors and out. They interrupt electrical power for equipment loads when leakage to ground is 4-6 milliamperes. Available in lengths GFP4C15M of 18 (45.7 cm), 6 (182.9 cm), and 25 (762 cm). A 15 (457.2 cm) OEM version with stripped leads is also available. They are offered with an Automatic Set or Manual Set feature to meet your application. Features and Benefits www.hubbell-wiring.com H-7

Portable GFCI Products Industrial Grade, Straight Blade Automatic and Manual Set Portable GFCI Line Cords Twist-Lock Manual Set Portable GFCI Line Cords IP21 SUITABILITY Automatic Set 15A Portable GFCI Line Cords 120V AC Catalog Numbers 18 (45.7 cm) GFCI line cord. GFP4C15A 6 (182.9 cm) GFCI line cord. GFP6C15A 25 (762 cm) GFCI line cord. GFP25C15A 15 (457.2 cm) GFCI power supply cord with GFPOEMA* stripped leads. Circuit Guard Manual Set 15A 20A Portable GFCI Line Cords 120V AC 120V AC Catalog Numbers 18 (45.7 cm) GFCI line cord. GFP4C15M 3 (91.4 cm) GFCI line cord. GFP3C20M 6 (182.9 cm) GFCI line cord. GFP6C15M 25 (762 cm) GFCI line cord. GFP25C15M 15 (457.2 cm) GFCI power supply cord with GFPOEMM* stripped leads. 50 (1524 cm) GFCI power supply with Elastogrip GFP50C15WM watertight straight blade. 100 (3048 cm) GFCI power supply with Elastogrip GFP100C15WM watertight straight blade. *Total length is 15 4.5 (468.6 cm) including leads: green 4.5 (114.3), black and white 3.5 (88.9). Each prestripped.375 (9.5). Circuit Guard Manual Set Twist-Lock Portable 15A 20A GFCI Line Cords 120V AC 120V AC Catalog Numbers 3 (91.4 cm) GFCI line cord. GFP3C15MTL GFP3C20MTL Automatic Set GFCI Automatically energizes or sets the GFCI for use upon plug in and after the loss of primary power (power failure or unplugging the device). After a ground fault condition, unit must be reset by pushing the reset button. This feature eliminates the need for unit to be reset each time it is plugged in or powered up. Ideal for equipment intended for continuous use where a temporary power failure is likely and undesirable. Examples are pumps, pressure washers, portable signs or lighting and engine heaters. Portable GFCI Line Cords 4 to 6 ma. Trip Time.025 sec. nominal. Voltage 120V AC +10% - 15%. Incorporates no voltage release feature. Current 15A/20A. Maximum Interrupting Capacity 2000A. -35 C to +66 C or -30 F to +150 F. Maximum Humidity 95%. Housing High-impact, UV stabilized PVC. UL 94V-0 flammability classification. Meets UL and CSA watertight requirements. Adhesive bonded. Cord Type SJTW-A (UL), SJTW (CSA). Visual Fault Indication Light On Indicates fault. Listing and Standards Meets UL943 2003 Class A UL File E41978 CSA Certified. Code Meets all NEC & CEC requirements. Manual Set GFCI Requires the GFCI to be manually set for use by pressing the reset button upon plug in and after loss of primary power (power failure or unplugging the device). Must be manually reset after a ground fault condition. Ideal for applications where operator injury might occur if equipment were to restart after a power failure. Typical equipment includes power drills, saws, lathes and grinders. GFP4C15A GFP3C20M GFPOEMM GFP3C20MTL Straight Blade Input 15A NEMA 5-15P, 20A NEMA 5-20P. Output 15A NEMA 5-15R (except GFPOEMM), 20A NEMA 5-20R. Twist-Lock Input 15A NEMA L5-15P HBL47CM20C, 20A NEMA L5-20P HBL23CM11. Output 15A NEMA L5-15R HBL47CM29C, 20A NEMA L5-20R HBL23CM13. H-8 www.hubbell-wiring.com

Commercial Grade Straight Blade Automatic and Manual Set Portable GFCI Line Cords 15A Portable GFCI Single Outlet 120V AC Catalog Numbers 2 (45.7 cm) GFCI line cord, automatic set. GFP2CA 2 (45.7 cm) GFCI line cord, manual set. GFP2CM 25 (45.7 cm) GFCI line cord, automatic set. GFP25CA 25 (45.7 cm) GFCI line cord, manual set. GFP25CM 15A Portable GFCI Triple Tap Outlet 120V AC Catalog Numbers 2 (45.7 cm) GFCI line cord, automatic set. GFP2TTA 2 (45.7 cm) GFCI line cord, manual set. GFP2TTM 25 (45.7 cm) GFCI line cord, automatic set. GFP25TTA 25 (45.7 cm) GFCI line cord, manual set. GFP25TTM 15A OEM Equipment Integrated Cord Sets 120V AC Catalog Numbers 15 (45.7 cm) GFCI with /flying leads, automatic set. GFP15LA 15 (45.7 cm) GFCI with /flying leads, manual set. GFP15LM 35 (45.7 cm) GFCI with /flying leads, automatic set. GFP35LA 35 (45.7 cm) GFCI with /flying leads, manual set. GFP35LM Portable GFCI Line Cords 4 to 6 ma. Trip Time.025 sec. nominal. Voltage 120V AC +10% - 15%. Incorporates no voltage release feature. Current 15A. Maximum Interrupting Capacity 2000A. -35 C to +66 C or -30 F to +150 F. Maximum Humidity 95%. Housing High-impact, UV stabilized PVC. UL 94V-0 flammability classification. Meets UL and CSA watertight requirements. Adhesive bonded. Cord Type #14 AWG SJTW-A (UL), SJTW (CSA). Visual Fault Indication Light On Indicates fault. Listing and Standards Meets UL943 2003 Class A UL File E41978 CSA Certified. Code Meets all NEC & CEC requirements. GFP2CA GFP2TTA GFP15LA Portable GFCI Products www.hubbell-wiring.com H-9

Portable GFCI Products Multiple Outlet Portable GFCI and GFCI Module GFP15M GFM20 Multiple Outlet Portable GFCI Rating Receptacles Plug Catalog Numbers 4 outlet, yellow. 15A,120V AC 2-Duplex 5-15R NEMA 5-15P GFP15M 4 outlet, yellow. 20A,120V AC 2-Duplex 5-20R NEMA 5-20P GFP20M GFCI Module IP21 SUITABILITY Rating Catalog Number GFCI module, 20A, 120V AC, 60 Hz GFM20 manual set, yellow. GFP15M/20M GFM20 4 to 6 ma. 4 to 6 ma. Trip Time.025 sec. nominal..025 sec. nominal. Voltage 120V AC +10% - 15%. 120V AC +10% - 15%. No voltage release feature. No voltage release feature. Max. Interrupting Capacity 5000A. 5000A. Current 15A/20A. 20A. -35 C to +66 C or -30 F to +150 F. -35 C to +66 C or -30 F to +150 F. Housing High-impact, yellow VALOX High-impact, UV stabilized, rigid PVC. with protective lift covers. UL 94V-0 flammability classification. Input 5-15P, 15A / 5-20P, 20A. #12 AWG stranded conductors (black/white/green). Output 5-15R(4), 15 Amp / 5-20R(4), 20 Amp. #12 AWG stranded conductors (red/gray). Power Supply Cord 6 (182.9 cm) STOW-A (STW FT2 CSA). N/A Mounting Screws N/A Self-tapping, combination, #6-32. Power ON Indication Neon indicator light. Neon indicator light. Agency Approvals UL Listed, UL948 for receptacles, UL Listed, CSA Certified. Meets UL943 2003, Class A for GFCI s. Meets UL943 2003, Class A for GFCI s. Codes Meets all NEC & CEC requirements. Meets all NEC and CEC requirements.????? H-10 www.hubbell-wiring.com

Hard Wired 30 Ampere GFCI Circuit Guard Hard Wired 30A GFCI Voltage Alarm Manual Set Automatic Set Hard wired, manual set 120V AC None GFHW13005 GFHW13105 and automatic set GFCIs. 120V AC Audible GFHW13015 GFHW13115 240V AC None GFHW23005 GFHW23105 240V AC Audible GFHW23015 GFHW23115 120/240V AC Audible GFHW33015 GFHW33115 3 250V AC Audible GFHW530 GFHW531 3 120/208V AC Audible GFHW430 GFHW431 Note: All units above are stock items. Build Your Own Catalog Number Catalog Number Configurator: Example: Catalog Number: GFHW23015 GF HW 2 3 0 1 5 Voltage Amperage Reset Type Output Signal Mounting Style Ground Hard- 1-120 V AC 3-30 Amp 0 - Manual 0 - none 5 - Panel Mount/ Fault Wired 2-240 V AC 1 - Automatic 1 - Audible Alarm Surface Mount 3-120/240V AC 4-3 120/208V AC 5-3 250V AC 2 - Line Voltage 3-24 Volt DC 4-12 Volt DC Note: 2 to 3 week lead time for all build your own catalog numbers. Electrical Ratings Rated Voltage 120V AC, 240V AC and 120/240V, 3 250V AC, 3 120/208V AC. Operating Voltage Range 85% to 110%. Current Up to 30A or device rating. 4-6 ma. Phase Single. Response Time.025 sec. Max. Dielectric Withstand 1500 VRMS across contact, 4000 VRMS between conductors and enclosure. Surge Withstand 6000V impulse,0.5 microseconds rise time 100 khz ringing frequency with 40% decay per cycle. Let go line voltage Grounded neutral detection Power up 60% of rated. 6 Ohms or less. Manual or automatic reset. Environmental Ratings Housing Rating UL Type 4X. Construction Industrial grade design. Type Class A GFCI. -35 C to +66 C. Leakage current @ 93% humidity Zero. Features Life (Endurance) Open neutral protection Grounded neutral protection Power on indicator Power off indicator Wiring application Switch interface Latching Mechanism 10,000 cycles (6000 w/ load & 4000 w/o load). Trips upon loss of neutral. Trips if ground and neutral touch at load side. Green light on. Red blinking light plus optional audible alarm. 3 Wire Single Phase (Hot, Neutral & Ground) 4 Wire Single Phase (Line 1, Line 2, Neutral and Ground). Double Insulated. Electromagnetic. Physical Wire Leads #10 AWG, 24 long. Unit Color Gray with black cover. Label color on portable and Automatic reset: yellow background w/ black hard wired units lettering. Manual reset: black background w/ yellow lettering. Weight 1.40 lbs. Dimensional Drawing Automatic Reset GFCI Manual Reset GFCI Hard Wired 30A GFCI www.hubbell-wiring.com H-11

Portable 30A GFCI Portable 30 Ampere GFCI GFP1311 Dimensional Drawing Electrical Ratings Rated Voltage Circuit Guard Portable 30A GFCI Cord Length Voltage Manual Set Automatic Set Portable, manual set 2 Foot 120V AC GFP1301 GFP1311 and automatic set GFCIs. 25 Feet 120V AC GFP1302 GFP1312 2 Foot 240V AC GFP2301 GFP2311 25 Feet 240V AC GFP2302 GFP2312 6 Feet 120/240V AC GFP3305 GFP3315 6 Feet 3 250V AC GFP5305 GFP5315 6 Feet 3 120/208V AC GFP4305 GFP4315 Note: All units above are stock items. Note: 2 to 3 week lead time for all build your own catalog numbers. 120V AC, 240V AC, 120/240V AC, 3 250V AC, 3 120/208V AC. Operating Voltage Range 85% to 110%. Current Up to 30A or device rating. 4-6 ma. Phase Single. Response Time 25 ms Max. Dielectric Withstand 1500 VRMS across contact, 4000 VRMS between conductors and enclosure. Surge Withstand 6000V impulse,0.5 microseconds rise time 100 khz ringing frequency with 40% decay per cycle. Let go line voltage Grounded neutral detection Power up Environmental Ratings Build Your Own Catalog Number 60% of rated. 6 Ohms or less. Manual or Automatic reset. Housing Rating UL Type 4X Construction Industrial grade design. Type Meets UL943 2003 Class A GFCI -35 C to +66 C Leakage current @ 93% humidity Zero Catalog Number Configurator: Example: Catalog Number: GFP2311 GF P 2 3 1 1 Voltage Amperage Reset Type Cord Length Ground Portable Hard- 1-120V AC 3-30 Amp 0 - Manual 1-2 Feet Fault Wired 2-240V AC 3-120/240V AC 4-3 120/208V AC 5-3 250V AC 1 - Automatic 2-25 Feet 3-50 Feet 4-100 Feet 5-6 Feet Features Life (Endurance) Open neutral protection Grounded neutral protection Power on indicator Power off indicator Wiring application Switch interface Latching Mechanism Physical 10,000 cycles (6000 w/ load & 4000 w/o load). Trips upon loss of neutral. Trips if ground and neutral touch at load side. Green light on. Red blinking light plus optional audible alarm. 3 Wire Single Phase (Hot, Neutral & Ground) 4 Wire Single Phase (Line 1, Line 2, Neutral and Ground.) Double Insulated. Electromagnetic. Cord Type 2-50, 10/3 SJGOOW, 100, 8/3 SEOW. Unit Color Gray with black cover. Label color on portable and Automatic reset: Yellow background w/ black hard wired units lettering. Manual reset: Black background w/ yellow lettering. Plug and Connector Selector Chart (partial listing) The chart below is a list of possible Hubbell plug and connector body products that can be used with the Hubbell Portable GFCIs. Family Hubbell Part Numbers Amps Voltage Style Insulgrip HBL5266C & HBL5269C 15 120V AC Straight Blade Ergo Grip HBL5567EY & HBL5579EY 20 240V AC Straight Blade Insulgrip HBL2621 & HBL2623 30 240V AC Twist-Lock Watertight Safety-Shroud HBL2621SW & HBL2623SW 30 240V AC Twist-Lock IEC Pin & Sleeve HBL330P6W & HBL330C6W 30 240V AC Watertight Pin & Sleeve Insulgrip Pin & Sleeve HBL330PS2W & HBL330CS2W 30 240V AC Insulgrip Pin & Sleeve Hubbellock HBL23035B & HBL23032B 20 120V AC Hubbellock Weight- 2 ft. 1.8 lbs., 6 ft. 2.7 lbs.,25 ft. 6.8 lbs., 50 ft. 12.4 lbs.,100 ft. 23.3 lbs. H-12 www.hubbell-wiring.com