TWIST-LOCK and HUBBELLOCK Devices
|
|
- Ethan Owens
- 8 years ago
- Views:
Transcription
1 Section B TIST-LOCK and HUBBELLOCK Devices Index Rating Type Page Number 15A 125V 2P 2, Midget Twist-Lock Non-rounding Devices B-2 15A 125V 2P 2, Twist-Lock Non-rounding Devices B-3 20A 250V 2P 2, Twist-Lock Non-rounding Devices B-4 Features and Benefits Midget Twist-Lock Devices B-5 15A 125V 2P 3, Midget Twist-Lock rounding Devices B-6 7 Features and Benefits 15A Twist-Lock Devices B-9 15A 125V, 250V and 277V AC 2P 3, Twist-Lock rounding Devices B Features and Benefits 20A and 30A Twist-Lock Devices B Features and Benefits 50A Twist-Lock Devices B-16 Features and Benefits 20A and 30A atertight Safety-Shroud Twist-Lock Devices B Features and Benefits 20A and 30A Safety-Shroud Twist-Lock Devices B-19 Features and Benefits CIRCUIT-LOCK Unfused Safety-Shroud Mechanical Interlock B-20 Compatibility Chart Twist-Lock Devices B-21 20A 125V, 250V and 277V AC 2P 3, Twist-Lock rounding Devices B A 125V, 250V and 277V AC 2P 3, Valise Twist-Lock rounding Devices B-25 20A 347V, 480V AC and 600V AC 2P 3, Twist-Lock rounding Devices B-26 30A 125V, 250V and 277V AC 2P 3, Twist-Lock rounding Devices B A 125V, and 250V 2P 3, Valise Twist-Lock rounding Devices B-30 30A 480V AC and 600V AC 2P 3, Twist-Lock rounding Devices B-31 50A 125V, 250V and 480V AC 2P 3, Twist-Lock rounding Devices B-32 50A 250V DC and 600V AC 2P 3, Twist-Lock rounding Devices B-33 15A 125/250V 3P 3, Midget Twist-Lock Non-rounding Devices B and 30A 125/250V 3P 3, Twist-Lock Non-rounding Devices B-36 20A 125/250V, 3Ø 250V AC and 3Ø 480V AC 3P 4, Twist-Lock rounding Devices B A 125/250V and 3Ø 250V AC 3P 4, Twist-Lock rounding Devices B A 3Ø 480V AC and 3Ø 600V AC 3P 4, Twist-Lock rounding Devices B A 125/250V, 3Ø 250V AC, and 3Ø 480V AC 3P 4, Twist-Lock rounding Devices B-46 50A 600V AC, 250V DC 3P 4, Twist-Lock rounding Devices B-47 20A 3Ø 120/208V AC, 277/480V AC and 347/600V AC 4P 4, Twist-Lock Non-rounding Devices B-48 30A 3Ø 120/208V AC, 277/480V AC and 347/600V AC 4P 4, Twist-Lock Non-rounding Devices B-49 20A and 30A 3Ø 120/208V AC 4P 4, Twist-Lock Non-NEMA, Non-rounding Devices B-50 20A 3Ø 120/208V AC, 277/480V AC and 347/600V AC 4P 5, Twist-Lock rounding Devices B A 3Ø 120/208V AC, 277/480V AC and 347/600V AC 4P 5, Twist-Lock rounding Device B A 250V, 10A 600V AC 4P 5, Twist-Lock Non-NEMA, rounding Devices B-57 30A 250V, 600V AC and 20A 3Ø 120/208V AC 400 Hz 4P 5, Variload Twist-Lock rounding Devices B-58 10A, 15A, 20A, and 30A 125V and 250V Non-NEMA, Not UL Listed Devices B Switched Twist-Lock and Hubbellock Enclosures B Switched Safety-Shroud Twist-Lock Enclosure B Accessories B Back Boxes for atertight Receptacles B-72 Add-A-Shroud B Amp Twist-Lock Accessories B-74 Features and Benefits Hubbellock Devices B-75 20A 125V 2P 3, Hubbellock rounding Devices B-76 30A 600V AC, 20A 250V DC 3P 4, Hubbellock rounding Devices B-77 30A 480V AC 3P 4, Hubbellock rounding Devices B-78 60A 600V AC 3P 4, Hubbellock rounding Devices B-79 30A 600V AC, 20A 250V DC 4P 5, Hubbellock rounding Devices B-80 60A 600V AC 4P 5, Hubbellock rounding Devices B-81 20A 125V AC or DC or 10A 250V DC and 480V AC 2P 3, Hubbellock rounding Not UL Listed Devices B-82 Technical Information B Locking Devices Index
2 2P 2, 15A, 125V Locking Devices TIST-LOCK Devices 2 Pole, 2 ire, Non-rounding 15 Ampere, 125 Volts Midget TIST-LOCK Flanged Receptacle, Plug, Connector Body and Flanged Inlet.16" (4.1).97" (24.6).16" (4.1) 1.63" (41.4) 1.38" (35.1) 1.03" (26.2) HBL " (31.8) HBL7465V HBL7464V 1.63" (41.4) 1.38" (35.1) 1.06" (26.9) 1.77" (45.0) HBL7466, HBL7467 HBL4890 HBL7459V.94" (23.9).78" (19.8) 1.06" (26.9) 1.06" (26.9) Flanged Receptacle Stainless steel flange, exposed terminals. Male Plug HBL7468 Cord Dia. Valise plug, black nylon HBL7465V ( ) Connector Body IP20 SUITABILIT Cord Dia. Valise connector body, black nylon, HBL7464V polarized. ( ) Flanged Inlets Stainless steel flange, polarized, HBL7467 exposed terminals. Stainless steel flange, not polarized, HBL7466 exposed terminals. eatherproofing Accessories NEMA ML-1R 15A 125V Seal-tite cover, black elastomer, for use with a HBL7465V when HBL7490V** * used with a HBL7464V connector body or a HBL7464V connector when used with a flanged inlet. Seal-tite cover, black elastomer, for use with a HBL7464V connector HBL7459V** * body and combination of HBL7465V plug and HBL7490V cover. Closure cover for use with HBL7466 or HBL7467. HBL4890 * Bead chain is nickel-plated. ** body IP55 combinations. suitability when installed and used properly with plug and connector * Not UL Listed. HBL7490V IP20 SUITABILIT NEMA ML-1P 15A 125V B-2
3 TIST-LOCK Devices 2 Pole, 2 ire Non-rounding 15 Ampere, 125 Volts Receptacles, INSULRIP Plug, Connector Body, Flanged Inlet and Flanged Receptacles Receptacles Duplex, flush, black phenolic. HBL7540 Single, flush, black phenolic. HBL7535 Single, panel mount, 1 15 /16 (49.2) HBL7498 centers, black phenolic. Insulgrip Plug IP20 SUITABILIT Cord Dia. Black and white nylon, polarized HBL7545C Multiple drive screws. ( ) Insulgrip Connector Body IP20 SUITABILIT Cord Dia. Black and white nylon HBL7506C Multiple drive screws. ( ) Insulgrip Flanged Inlet Nylon casing, polarized, backwired, HBL7524C Multiple drive screws. Flanged Receptacles Insulgrip nylon casing, backwired. HBL7526C Multiple drive screws. Metal flange, stainless steel casing, HBL7526 black phenolic, exposed terminals. Notes: Only receptacles and plugs are HP rated. HP ratings are AC only. See pages B-66 and B-67 for accessories..16" (4.1) 2.56" (65.0) 2.19" (55.6) HBL7524C 1.72" (43.7) 1.69" (42.9).16" (4.1) 2.19" (55.6) 2.56" (65.0) 1.72" (43.7) NEMA L1-15R 15A 125V UL Listed 0.5 HP 1.69" (42.9) NEMA L1-15P 15A 125V UL Listed 0.5 HP 3.28" (83.3) 3.28" 1.39" (83.3) (60.5) 2.38" (35.3) 1.94" 1.39" (49.3)(35.3) 1.53" (38.9) #6-32 TAP 1.53" (38.8) 1.11" (28.2) #8-32TAP #6-32 TAP HBL7540 HBL " (35.3) HBL7498 HBL7545C 2.78" (70.6) 1.33" (33.8) 1.91" (48.5) HBL7506C 1.00" (25.4) 1.19" (30.2) 1.19" (30.2) 1.00" (25.4) 1.63" (41.4) 1.00" (25.4) 1.63" (41.4) 1.19" (30.2) 1.53" (38.9) 2.75" (69.9) 1.41" (35.8) Locking Devices 2P 2, 15A, 125V B-3
4 2P 2, 20A, 250V Locking Devices TIST-LOCK Devices 2 Pole, 2 ire Non-rounding 20 Ampere, 250 Volts Receptacles, INSULRIP Plug, Connector Body Flanged Inlet, Flanged Receptacles 1.53" (38.9) 2.09" (53.1).16" (4.1).16" (4.1) 1.30" (33.0) 1.11" (28.2) 1.41" (35.8) HBL7210B 2.78" (70.6) HBL7101C 2.56" (65.0) 2.19" (55.6) 1.69" (42.9) HBL8815C 2.56" (65.0) 1.69" (42.9) HBL8809C 1.88" (47.8) 1.42" (36.1) HBL " (35.3) (60.5) 2.38" (83.3) 3.28" #6-32 TAP 1.91" (48.5) HBL7102C 1.72" (43.7) 1.72" (43.7) 1.83" (46.4) 2.19" (55.6) 1.53" (38.9) 1.41" (35.8).16"(4.1) Receptacles Single, black phenolic. HBL7210B Single, mounted on 4 (101.6) HBL7217B round box cover, black phenolic. Insulgrip Plug Cord Dia. Black and white nylon, polarized HBL7102C Multiple drive screws. ( ) Insulgrip Connector Body Cord Dia. Black and white nylon HBL7101C Multiple drive screws. ( ) Insulgrip Flanged Inlet Nylon casing, back wired, polarized. HBL8815C Multiple drive screws. Flanged Receptacles NEMA L2-20R 20A 250V UL Listed 2 HP NEMA L2-20P 20A 250V UL Listed 2 HP Insulgrip nylon casing, back wired. HBL8809C Multiple drive screws. Metal flange, stainless steel casing, HBL3226 black phenolic, exposed terminals. Notes: Only receptacles and plugs are HP rated. Horsepower ratings listed above are AC only. See pages B-66 and B-67 for accessories. B-4
5 TIST-LOCK Devices Midget TIST-LOCK Devices Assembly screws have multiple drive heads for screwdriver versatility. Only two assembly screws are needed to close this device, make the wire terminations and retain the cord. Powerful, cord-gripping jaws designed to eliminate conductor slip and strain on terminals. Hubbell s Valise insulation displacement terminal for Midget Twist-Lock plugs and connector bodies are the right choice for economy, wiring speed and long life. Totally insulated body adds extra measure of safety. Abuse resistant nylon housing. Patented locking lugs interlock the two sections together when the device is assembled providing a secure assembly in abusive environment. Nylon webs join two sections together which makes assembly of the device quick and easy. The insulation displacement terminal reduces the time required for wire preparation and provides uniformity in the quality of termination. TURN & PULL marking is highly visible, reducing possible damages to equipment by attempting disconnection prior to unlocking. Locking Devices Features and Benefits B-5
6 2P 3, 15A, 125V Locking Devices TIST-LOCK Devices 2 Pole, 3 ire rounding 15 Ampere, 125 Volts Midget TIST-LOCK Devices 1.17" (29.7) 1.00" (25.4).16" (4.1) 1.19" (30.2) 2.06" (52.3) 1.75" (44.5) 1.14" (29.0) HBL7596N 2.06" (52.3) 1.75" (44.5) 1.17" (29.7) HBL " (52.3) 1.75" (44.5) 1.17" (29.7) HBL7598 HBL7594V 2.00" (50.8) 1.61" (40.9) 1.59" (40.4) HBL " (24.6) 1.25" (31.8).15" (3.8).16" (4.1) 1.13" (28.7) Flanged Receptacles Exposed terminals, black nylon flange. HBL7596N Exposed terminals, stainless steel flange. HBL7596 Covered terminals, stainless steel flange, HBL7598 accepts cord.500 (12.7) in dia. Male Plugs IP20 SUITABILIT Cord Dia. Valise male plug, black nylon, insulation HBL7594V displacement terminals. ( ) Black nylon cover, phenolic body, HBL7594 multiple drive screw terminals. ( ) Angle plug, black nylon cover, phenolic HBL7570 body, multiple drive screw terminals. ( ) eatherproof Accessory IP55** SUITABILIT Seal-Tite cover, black elastomer, for use with a HBL7594V plug HBL7495V** * when used with a HBL7593V connector body or a HBL7593V connector body when used with a flanged inlet. Notes: These devices are not interchangeable with any other devices in this catalog. All male ground pins are sleeves and female device grounds are split pin. **IP55 Suitability when installed and used properly with plug and connector body combination. * Not UL Listed..86" (21.8) 1.69" (42.9) 1.17" (29.7) HBL7570 R NEMA ML-2R 15A 125V HBL7495V NEMA ML-2P 15A 125V R B-6
7 TIST-LOCK Devices 2 Pole, 3 ire rounding 15 Ampere, 125 Volts Midget TIST-LOCK Devices Connector Bodies IP20 SUITABILIT Cord Dia. Valise connector body, black nylon, HBL7593V insulation displacement terminals. ( ) Black nylon cover, phenolic body, HBL7593 screw terminals. ( ) Angle connector body, black nylon cover, HBL7571 phenolic body, screw terminals. ( ) Flanged Inlets Exposed terminals, black nylon flange. HBL7595N Exposed terminals, stainless steel flange. HBL7595 Covered terminals, stainless steel flange, HBL7551 accepts cord.500 (12.7) dia. eatherproof Accessories IP55** SUITABILIT Seal-Tite cover, black elastomer, for use with a HBL7593V HBL7440V** * connector body and a combination of HBL7594V plug and HBL7495V cover. Closure cover for use with HBL7595 or HBL7595N. HBL4889 * Notes: These devices are not interchangeable with any other devices in this catalog. All male ground pins are sleeves and female device grounds are split pin. **IP55 Suitability when installed and used properly with plug cover and connector body combination. * Not UL Listed. HBL7440V R HBL4889 NEMA ML-2R 15A 125V NEMA ML-2P 15A 125V R 1.13" (28.7) 1.28" (32.5) 1.00" (25.4).16" (4.1) 1.98" (50.4) HBL7593V 2.42" (61.5) HBL " (42.9) 1.17" (29.7) HBL " (52.3) 1.75" (44.5) 1.28" (32.5) HBL7595N 2.06" (52.3) 1.75" (44.5) 1.22" (31.0) HBL " (3.8) 1.00" (25.4) 1.19" (30.2) 1.17" (29.7) Locking Devices 2P 3, 15A, 125V B-7
8 Locking Devices TIST-LOCK Devices
9 TIST-LOCK Devices INSULRIP 15 Ampere Plugs and Connector Bodies Featuring Integral VARI-SIE Cord rip Individually molded face for each blade configuration keeps debris out of plug interior. Roomy wiring chamber provides ample space for wiring. Individual wiring terminals are completely enclosed in their own separate chambers. Powerful, offsetting cord grips clamp on individual conductors and outer cord jacket to prevent strain on terminals. Ribbed nylon housing is impact and chemical resistant. Beveled housing prevents snagging when dragged across uneven surfaces. Integral VARI-SIE insert adjusts to a wide range of cord sizes: ( ). VARI-SIE pointer set to smaller than gauge position. Cord diameter range is ( ). Accepts slotted and Phillips head drivers. Catalog number is visible on the device while in use for easy identification. Multiple drive screw heads provide screwdriver versatility. Pocketed recess for cord grip screws deters slippage of the screwdriver. Transparent angled wiring entrance holes permit straight in conductor insertion. Powerful offsetting cord grips clamp on individual conductors and outer cord jacket to prevent strain on terminations. Locking Devices Features and Benefits B-9
10 2P 3, 15A, 125V, 250V and 277V AC Locking Devices TIST-LOCK Devices 2 Pole, 3 ire rounding 15 Ampere, 125, 250 Volts and 277 Volts AC Duplex and Single Receptacles 3.28" (83.3) 2.38" (60.5) 1.38" (35.1) 1.94" 1.75" 1.38" (49.3)(44.5)(35.1) 1.70" (43.2) HBL " (32.3) HBL " (32.3) HBL " (69.5) 3.28" (83.3) 1.42" (36.1) Duplex Receptacles, Back and Side ired Flush, brown RTP face. HBL4700* HBL4550* HBL4750* Flush, ivory RTP face. HBL4700I* Fed Spec C596 Special Purpose Duplex Receptacles Back and Side ired Isolated ground, flush, orange RTP face. I4700A* I4550A* Corrosion resistant, yellow RTP face. HBL47CM00* Fed Spec C596 Single Receptacle, Back and Side ired Flush, black nylon face. HBL4710 HBL4560 HBL4760 Special Purpose Single Receptacles, Back and Side ired Isolated ground, flush, orange nylon face. I4710 I4560 Single, black nylon face mounted on a HBL4711 HBL (101.6) round box cover. Panel mount, black nylon face, side wired HBL4713 HBL4563 HBL4763 only, 1.75 or (44.5 or 49.2) mounting centers. Notes: HP ratings are AC only. RTP is an abbreviation for reinforced thermoplastic polyester. See Section J for full line of isolated ground devices. See pages B-66 and B-67 for accessories. *Supplied with break-off tabs for split circuit wiring. NEMA L5-15R 15A 125V 0.5 HP NEMA L6-15R 15A 250V 1.5 HP NEMA L7-15R 15A 277V AC 2 HP B-10
11 TIST-LOCK Devices 2 Pole, 3 ire rounding 15 Ampere, 125, 250 Volts and 277 Volts AC Plugs and Connector Bodies Plugs IP20 SUITABILIT Cord Dia. Insulgrip plug, HBL4720C HBL4570C HBL4770C black and white nylon. ( ) Multiple drive screws. Fed Spec C596 Insulgrip plug, HBL47CM20C HBL45CM70C HBL47CM70C corrosion resistant, ( ) yellow and white nylon. Multiple drive screws. Fed Spec C596 Elastogrip plug, yellow HBL2447 elastomer, dust tight. ( ) Elastogrip plug, yellow HBL2447* elastomer, water/dust tight.( ) Valise plug, HBL4723V HBL4573V HBL4773V yellow nylon. ( ) Valise plug, HBL4723VBK HBL4573VBK HBL4773VBK black nylon. ( ) Note: *atertight plug IP55 suitability when installed and used with watertight connector body. Connector Bodies Cord Dia. Insulgrip connector HBL4729C HBL4579C HBL4779C body, black and white nylon.( ) Multiple drive screws. Insulgrip connector body, HBL47CM29C HBL45CM79C HBL47CM79C corrosion resistant, ( ) yellow and white nylon. Multiple drive screws. Elastogrip connector body, HBL2547 yellow elastomer, dust tight. ( ) Elastogrip connector body, HBL2547* yellow elastomer, ( ) water/dust tight. Valise connector body, HBL4729V HBL4579V HBL4779V yellow nylon. ( ) Valise connector body, HBL4729VBK HBL4579VBK HBL4779VBK black nylon. ( ) Notes: See pages B-66 and B-67 for accessories. HP ratings are AC only. Only plugs are HP rated. For technical information on Insulgrip devices see page B-83. *atertight connector body IP55 suitability when closure plug inserted or when installed and used properly with watertight plug. NEMA L5-15P 15A 125V 0.5 HP NEMA L5-15R 15A 125V NEMA L6-15P 15A 250V 1.5 HP NEMA L6-15R 15A 250V NEMA L7-15P 15A 277V AC 2 HP NEMA L7-15R 15A 277V AC 1.56" (39.6) 1.53" (38.9) 1.50" (38.1) HBL4729C HBL " (65.8) HBL4720C HBL " (47.8) HBL4723V 2.78" (70.6) 1.75" (44.5) 1.91" (48.5) HBL4729V 2.63" (66.8) 4.00" (101.6) 1.50" (38.1) 1.53" (38.9) 1.41" (35.8) Locking Devices 2P 3, 15A, 125V, 250V and 277V AC B-11
12 2P 3, 15A, 125V, 250V and 277V AC Locking Devices TIST-LOCK Devices 2 Pole, 3 ire rounding 15 Ampere, 125, 250 Volts and 277 Volts AC Angle Devices, Flanged Inlets, and Flanged Receptacles.16" (4.1).16" (4.1).16" (4.1).16" (4.1) 1.22" (30.9) 1.53" (38.9) HBL4720CA 2.56" (65.0) 2.19" (55.6) 1.69" (42.9) HBL4715C 2.31" (58.7) 1.94" (49.3) 1.50" (38.1) HBL " (52.3) 2.19" (55.6) 1.69" (42.9) HBL4716C 2.31" (58.7) 1.94" (49.3) 1.50" (38.1) HBL " (53.6) 1.72" (43.7) 1.75" (44.5) 1.36" (34.5) 1.72" (43.7) 1.75" (44.5) 1.09" (27.7) IP20 SUITABILIT Angle Plugs Cord Dia. Insulgrip plug, HBL4720CA HBL4570CA HBL4770CA 8 position angle, ( ) black and white nylon. Multiple drive screws. IP20 SUITABILIT Angle Connector Body Cord Dia. Insulgrip connector body, HBL4729CA 8 position angle, ( ) black and white nylon. Multiple drive screws. Flanged Receptacles Insulgrip flanged receptacle, HBL4715C HBL4585C HBL4785C nylon casing, back wired. Stainless steel casing, HBL4715 HBL4585 HBL4785 brown phenolic. Corrosion resistant, stainless steel HBL47CM15 casing, yellow melamine. Flanged Inlets Insulgrip flanged inlet, HBL4716C HBL4586C HBL4786C nylon casing, back wired. Stainless steel casing, HBL4716* HBL4586* HBL4786* brown phenolic. Corrosion resistant, stainless steel HBL47CM16* casing, yellow melamine. Notes: See pages B-66 and B-67 for accessories. Only plugs are HP rated. HP ratings are AC only. *These flanged inlets will not accept Valise connector bodies. NEMA L5-15P 15A 125V 0.5 HP NEMA L5-15R 15A 125V NEMA L5-15R 15A 125V NEMA L5-15P 15A 125V NEMA L6-15P 15A 250V 1.5 HP NEMA L6-15R 15A 250V NEMA L6-15R 15A 250V NEMA L6-15P 15A 250V NEMA L7-15P 15A 277V AC 2 HP NEMA L7-15R 15A 277V AC NEMA L7-15R 15A 277V AC NEMA L7-15P 15A 277V AC B-12
13 TIST-LOCK Devices Locking Devices
14 Features and Benefits Locking Devices The Standard for Locking Receptacles Features and Benefits Boss diameter is 1.562" on 20 and 30A devices for simplifying installation and accessory selection. lass-reinforced thermoplastic polyester base (RTP) has the desirable characteristics of a thermoset material, including heat, flame resistance and dimensional stability. The impact resistance it provides, however, is much greater than that of a thermoset. One-piece contact with long spring arm (low stress) and oxide cutting nibs: prevents stress and overheating associated with riveted contact and short spring arms. High-impact, abuse-resistant nylon face. Face color coding by voltage facilitates locating and mating of proper devices. On the high-impact nylon face of each Hubbell Twist-Lock receptacle is a ring of color. Keyed to an internationally recognized color coding scheme, this ring enables mating devices to be matched quickly. It s just one more example of user-oriented thinking at Hubbell. Twist-Lock receptacles have always held advantages over conventional ones. Today s Twist- Lock receptacles maintain the advantage by combining functional design features, unparalleled quality and pace-setting performance. The terminals in each Hubbell Twist-Lock receptacle are mechanically and electrically the finest available. These terminals incorporate unique design features to contain and hold conductors, including an external backwiring #10 silicon bronze terminal screw provides greater strength and resistance to corrosion and stripping. Anti-rotational clamp has a stop to limit the amount of cocking when only one side is used. Accommodates both back and side wiring. All-brass mounting and grounding system provides a lower resistance ground path and greater resistance to corrosion than steel mounting systems. ire restraint recess for both back and side wiring, greatly reduces the possibility of loosening the terminal connection. wraparound clamp, a wire restraint recess and more. The materials used in every receptacle are of the highest quality. The all brass mounting system provides a safer, lower resistance ground path than those made of steel. The thick wall base is constructed of an engineered thermoplastic to offer the benefits of a thermoset, yet with much greater impact resistance. Hubbell Twist-Lock Receptacles: Voltage color coding on the outside. Proven designs and quality materials on the inside. Any way you look at them, they re the standard of the industry. 125V 250V 277V AC 480V AC 600V AC 125/250V B-14
15 20 and 30 Ampere Plugs and Connector Bodies: The Difference Is INSULRIP...and a hole Lot More Features and Benefits Tough ribbed nylon housing for secure gripping. Two-part cord grip tightens with two screws for maximum retention force. Broad gripping area to accommodate wide range of cable diameters. iring chambers separate and positively insulate conductors and promote easy inspection. Insulated nylon construction to keep non-current carrying parts from becoming energized. They re new and better than ever. They re the same and better than anything else on the market. They re 20 and 30 amp Insulgrip plugs and connectors. e kept the same classic integrity, rock-solid construction and safety features that have made these devices the industry standard. But, we added enhancements because good is never good enough for Hubbell. e improved the contacts with better terminations and an exclusive double rivet design for the female contacts. e restyled the cord grips for a clean, one-piece look and made them stronger at the same time. And we introduced a whole new easier to read identification system. And more, all the while, of Improved terminations include #10 multiple drive screws and thicker.080" clamping nuts. Funneled holes to permit "straightin" conductor insertion. Self-threading screws specially designed for secure assembly. Product indentification is visible while device is in use. Markings include catalog number and ratings printed in the IEC color scheme on the current-carrying portion of the device. Integral dust shield protects wiring chamber from dust or contaminants. Single-piece shield/housing eliminates need for separate step at installation. course, we maintained traditional Insulgrip features and benefits. Like the most powerful cord grip in the industry. Insulgrip s cord gripping design actually clamps the conductors, not just the cable jacket. e kept the same nylon body and housing material for resistance to industrial chemicals, solvents and hydrocarbons. And, the front of each plug is still molded to its specific blade configuration, leaving no holes to invite debris or contamination (plus we added a new dust shield). Of course, the Hubbell Twist-Lock line of plugs and connectors remains the broadest in the industry. So if you prefer proven performance, innovation and selection Hubbell has you covered. Locking Devices Features and Benefits B-15
16 Features and Benefits Locking Devices 50 Ampere Plugs and Connector Bodies: The Difference Is INSULRIP...and a hole Lot More Features and Benefits Padlockable shroud allows compliance to OSHA lockout tagout regulation 29 CFR Three-piece thermoplastic clamp assembly with stainless steel fast lead screws provides a more consistent, durable grip. Sealed cable entry keeps out moisture and dust. Stainless steel shroud cannot be distorted to mate with the wrong device. Box terminal with hex socket threaded slug is superior because it permits high clamping pressure on conductors without damaging strands. Heavy-duty design for heavy-duty applications. These Hubbell 50A Twist-Lock plugs and connector bodies are built to go where you need power...even in some of the harshest environments. On the outside, 50A plugs and connectors are made of Super tough nylon for better impact resistance. On the plug, the stainless steel shroud not only provides protection and durability, but safety as well. That s because the rigid construction cannot be distorted, thus minimizing the possibility of mating incorrect devices. Rynite is a registered trademark of E. I. Dupont. Super tough nylon housing offers better impact qualities than regular nylon. Housing assembly latch slotted to fit standard flat-blade screwdriver providing secure assembly and fast disassembly for wiring. Thermoplastic polyester interior provides heat resistance and impact strength. 6/6 nylon nose thermoplastic polyester terminal cover provides heat resistance in terminal area and impact strength of nose piece. One-piece grounding contact on 4-wire devices provides a more reliable grounding system for a safer device. On the inside are the kinds of features that separate Hubbell from all the rest. The cord grip has been designed with offset gripping jaws to securely hold the conductors not just the cord jacket. Hubbell s box terminals speed wiring and provide a superior termination. The plug s Rynite thermoplastic interior provides excellent heat resistance without compromising strength. In all, it s the combination of function and performance that Hubbell demands of all its products. And it s why we ll never add a feature that compromises performance. B-16
17 Safety-Shroud TIST-LOCK System Hubbell Leads the ay in Safety Again Features and Benefits Next-eneration Hubbell Twist-Lock: Here Today Introducing the next generation of the original: the Hubbell Twist-Lock. The Hubbell 20A and 30A Insulgrip Twist-Lock product line has been expanded to provide a complete family of Safety-Shroud Twist- Lock devices. In this all-new line, plug blades are protected by a fixed shroud that shields the blades from possible deformation and, even more importantly, virtually eliminates user contact with an energized partially connected plug. These products set an entirely new standard for improved safety and reliability, and are available in two distinct series: Safety-Shroud Twist-Lock atertight Safety-Shroud Twist-Lock The atertight Safety-Shroud Twist-Lock series has achieved a UL Type 4 rating, which is capable of withstanding the ingress of water under hose-down conditions. The entire outer shell is molded of a high impact UL 94V-0 rated engineered thermoplastic. A complete line of receptacles, plugs, connector bodies and inlets is available in the most commonly required configurations and ratings. The Safety-Shroud Twist-Lock series is intended for installation where watertightness is not a factor, but the added safety of the shrouded design is highly desirable. Here again, the Safety-Shroud is molded of an engineered thermoplastic for a very high level of impact resistance. In order to satisfy every application and every need, Hubbell offers this series in three different styles of receptacles surface, angle and semi-flush. hether the needs are maintenance and repair, renovation or new construction, there is a receptacle design to accommodate your needs. In addition, this series offers Safety-Shroud plugs and even a separate Safety-Shroud kit that can be used to convert the standard Insulgrip Twist-Lock plug into the shrouded design. To provide an additional measure of safety in the workplace, Hubbell goes beyond shrouding to provide mechanically interlocked enclosures, designed expressly for use with this series, that virtually prevent the connecting and disconnecting of equipment under load. It s another Hubbell first in the industry...the Mechanically Interlocked Twist-Lock. As always, it s extremely important to us that all our products achieve a high level of compatibility with your existing Twist-Lock device installations. First and foremost, the new Safety-Shroud series embodies the basic NEMA configurations. Therefore, all shrouded receptacles easily accept the standard NEMA locking plugs already in use in your facility. A complete compatibility chart appears on page B-21 to explain every circumstance. Hubbell Twist-Lock with our new Safety-Shroud: changes the standard of safety forever. atertight Mechanical Interlock For Safety- Shroud Twist-Lock Hubbell s CIRCUIT-LOCK enclosure line has been expanded to include a mechanical interlock designed for use with the new Safety- Shroud Twist-Lock line. The addition of this mechanical interlock will complete your Safety-Shroud Twist-Lock industrial wiring system. The mechanical interlock is a breakthrough in design and virtually eliminates the possibility of making or breaking the circuit under load. Back Boxes Hubbell manufactures an extensive line of back boxes for use with the new Safety Shroud Twist-Lock system. Each back box is designed to give the user the maximum amount of wiring room while achieving grounding to metallic conduit. Hubbell back boxes are available in non-metallic and cast metal versions. atertight Safety-Shroud Twist-Lock This Type 4 rated product line is offered in a complete family consisting of plugs, connector bodies, receptacles and inlets. Tough and tight, these products are unequaled in performance in even the most hostile applications. Safety-Shroud Twist-Lock here watertightness is not a factor but the added margin of safety from the Hubbell Safety-Shroud Twist-Lock is we offer a total product line for all applications. In addition to Safety-Shroud plugs, the new line includes nonwatertight receptacles in three styles angle, surface and semi-flush to satisfy every installation need. Locking Devices Introduction B-17
18 Features and Benefits Locking Devices atertight Safety-Shroud TIST-LOCK System Receptacles, Plugs, Connector Bodies and Flanged Inlets Features and Benefits Closure cap is included for environmental seal when device is not in use. One-piece, engineered thermoplastic housing is impact-resistant for heavyduty industrial environments. All screws are #10 multiple drive head. Catalog number and color-coded voltage rating are easily visible even when in use. Universal Neoprene Diaphragm Seal Seal accommodates a wide range of cord sizes from #16-3 Type SJ to #8-5 Type S, SO. Panel Or Box Mount Receptacles And Inlets High impact, thermoplastic housing for heavy-duty industrial environments. Catalog number and color-coded voltage rating are easily visible when in use. Stainless Steel 302/304, #10 multiple drive head mounting screws provide corrosion resistance. Mounting screw recesses minimize screwdriver slippage. Lockout/tagout hole on inlets allow compliance to OSHA regulation 29 CFR Neoprene closure cap provided with inlets for environmental seal when not in use. Accepts all mating NEMA locking plugs and most connector bodies, allowing interchangeability with existing devices. External keying provides quick mating of devices. Blades are recessed for protection against bending and breaking. Alignment arrows and lock and unlock symbols provide a visual indication that devices are properly connected. Cord grip screw recess minimizes screwdriver slippage. One-step automatic Neoprene sealing gland and engineered thermoplastic guard assure sealing when device is fully connected. Spring-Loaded Cover One-step push-to-close spring-loaded cover with latch allows for fast opening and closing of lift cover. Result: environmental sealing is assured. Safety-Shroud Virtually eliminates bent and broken plug blades, leading to longer equipment life. Extends life of mating receptacles by eliminating damage caused by insertion of bent blades. Extra protection for personnel by significantly reducing chance of inadvertent contact with blades when connecting or disconnecting energized receptacles and connector bodies. Reduces exposure to arcing when connecting or disconnecting plugs under load. Compliance with California Code of Regulations, Title 8, Article 51, subsection (b), which requires shrouding for devices exceeding 300 volts. Lockout/tagout hole allows compliance with OSHA regulation 29 CFR Sealing gland and thermoplastic guard assure sealing when fully connected. B-18
19 Safety-Shroud TIST-LOCK System Receptacles and Plugs Features and Benefits Impact resistant shroud made of engineered thermoplastic protects blades against bending or breaking. External keying on plug devices allows quick mating of devices. All screws are #10 multiple drive head. Semi-flush receptacle mounting provides lowest installed profile when plug is not in use with receptacle. This device is designed for installation on 2 gang boxes. Alignment arrows and lock and unlock symbols provide a visual indication that devices are properly connected. Lockout/tagout hole allows compliance with OSHA regulation 29 CFR Safety-Shroud Plug Features and Benefits Mates with most NEMA locking Extends life of mating receptacles by connector bodies. eliminating damage caused by Virtually eliminates bent and broken insertion of bent blades. plug blades. Complies with California Code of Provides protection for personnel by Regulation, which requires shrouding reducing chance of inadvertent contact for devices exceeding 300 volts. with blades when connecting or Lockout/tagout hole allows compliance disconnecting energized devices. to OSHA regulation 29 CFR Reduces exposure to arcing when Allows engagement with Mechanical connecting or disconnecting under Interlock Enclosure which virtually load. prevents make and break under load. Straight receptacle housing provides a low installed profile when plug is not in use with receptacle. This device is designed for installation on singlegang boxes. Receptacle Features and Benefits Internal keying on receptacles aligns Catalog number and color-coded blades for quick mating of devices. voltage rating are visible when in use. Accepts all NEMA locking plugs, All screws are #10 multiple drive head. allowing interchangeability with existing devices. Catalog number and color-coded voltage rating are visible even when in use. Engineered thermoplastic housing is impact and corrosion resistant, making it suitable for heavy-duty industrial environments. Angle receptacle housing provides low installed profile when plug is in use with receptacle. This device is designed for installation on single-gang boxes. Engineered thermoplastic housing is impact and corrosion-resistant, for use in heavy-duty industrial environments. Locking Devices Features and Benefits B-19
20 Features and Benefits Locking Devices Switched Safety Enclosures CIRCUIT-LOCK Unfused Safety-Shroud TIST-LOCK Mechanical Interlock Features and Benefits Lockable handle provides lockout protection for greater safety and compliance with OSHA lockout requirements. Heavy-duty interlock linkage prevents make and break under load. Horsepower rated switch. Heavy-duty internal frame bonds conduit and all grounds and has a DIN rail to accommodate the switch. Hubbell introduces the first mechanical interlock for Twist- Lock. This new, unfused mechanical interlock for watertight Safety-Shroud Twist- Lock integrates a watertight receptacle with a linked disconnect switch to provide a mechanically interlocked receptacle. This virtually eliminates the possibility of making or breaking the circuit Moveable feet may be used in horizontal or vertical position. while under load or making a casual or lazy connection. The switch cannot be turned ON until the plug is properly inserted and locked, and the plug cannot be removed until the switch is turned OFF. All these protective features are included in a compact Type 4 hose-directed water and corrosion resistant enclosure that allows for top, bottom or back feed options. The Angled 20 or 30 Amp Hubbell atertight Safety-Shroud Twist-Lock receptacle provides watertight, low profile and mechanical interlock capabilities. Enclosure back is designed for top, bottom or back feed options. Premolded conduit entry hole is offset to prevent water condensation from falling directly on to interior electrical components. Also speeds installation by making it easier to pull conductors. non-metallic enclosure is nonconductive, yet has an internal frame to assure ground continuity with metallic conduit. In addition, this interlock works with all Safety-Shroud Twist-Lock plugs. The new unfused mechanical interlock for watertight Safety-Shroud Twist- Lock can be locked out as a method of compliance with OSHA lockout/tagout regulations. B-20
21 TIST-LOCK System Compatibility and Environmental Protection atertight Safety-Shroud, Safety-Shroud and NEMA Devices Twist-Lock Plugs Twist-Lock Receptacles Switched Twist-Lock Enclosure PSJO IST OTN CAT. NO. SSFIT ISTI ERQ QQ FIT TIEH SALAKJ SKA OFF ON CAUTION: Saitiew ietioeta sitieb owtosntownf wthuil sothe othes ot istelsls tiesntofoenls. ATTENTION: Alsritwheta dithe otehl sothe toehs wopt thlslei toenll sl lsjtel oetyhenl iteh sithe ithelsl tihehhll. Twist-Lock Connector Bodies atertight Safety- Shroud Mechanical atertight atertight Interlock Switched Safety- Safety-Shroud Enclosure Safety-Shroud Enclosure NEMA Shroud NEMA atertight ES ES ES NO NO ES ES Safety- Type 4, Type 4, Type 1 Type 4, Type 1 Shroud Type 12 Type 12K Type 12 Safety- ES ES ES NO NO ES ES Shroud Type 1 Type 1 Type 1 Type 1 Type 1 NEMA ES NO ES ES ES ES ES Type 1 Type 1 Type 3R Type 1 Type 1 Type 1 Twist-Lock Inlets NEMA NA NA NA NA NA NO ES Type 1 atertight NA NA NA NA NA ES ES Safety- Type 4, Type 1 Shroud Type 12 Type 1 Indoor Type 3R Raintight Type 4 Hose-directed water and corrosion resistant Type 12 Dust tight, dripproof without knockouts Type 12K Dust tight, dripproof with knockouts ES Interchangeable NO Does not interchange NA Not Applicable Refer to section for full description of enclosure types. Locking Devices Compatibility and Environmental Protection Chart B-21
22 2P 3, 20A, 125V, 250V and 277V AC Locking Devices TIST-LOCK Devices 2 Pole, 3 ire rounding 20 Ampere, 125, 250 Volts and 277 Volts AC Receptacles, INSULRIP Connector Bodies, Flanged Devices and Plugs 2.26" (57.4) 1.25" R. (31.8) 1.97" (50.0) 2.67" (67.8).98" (24.9) 1.25" R. (31.8) 1.70" (43.2) HBL HBL " (51.8) HBL " (98.0) 2.88" (73.2) 2.75" (69.9) HBL " (73.2) 1.23" (31.2) 2.04" (51.8) HBL " 2.38" (39.6)(60.5)(83.3) 3.28" #6-32 TAP.19" (4.8) " (53.1).19" (4.8) " (53.1) 1.97" (50.0) 2.26" (57.4) Single Flush Receptacles, Back and Side ired Black nylon face. HBL2310 HBL2320 HBL2330 Isolated ground, orange nylon face. I2310 I2320 Corrosion resistant, yellow nylon face. HBL23CM10 Insulgrip Connector Bodies Black and white nylon. HBL2313 HBL2323 HBL2333 Corrosion resistant, yellow nylon. HBL23CM13 HBL23CM23 Note: Cord clamp range (9-24). Insulgrip Flanged Receptacles Nylon casing, back wired. HBL2316 HBL2326 HBL2336 Insulgrip Plugs IP20 SUITABILIT Black and white nylon. HBL2311 HBL2321 HBL2331 Corrosion resistant, yellow nylon. HBL23CM11 HBL23CM21 Notes: Cord grip range (9-24). See page B-73 for Add-A-Shroud kit. NEMA L5-20R 20A 125V 1 HP Insulgrip Flanged Inlets Nylon casing, back wired. HBL2315 HBL2325 HBL2335 Notes: See pages B-68 and B-69 for accessories. See page B-63 for switched enclosure. For technical information see page B-83. HP ratings are AC only. Only receptacles and plugs are HP rated. IP20 SUITABILIT NEMA L5-20P 20A 125V 1 HP NEMA L6-20R 20A 250V 2 HP NEMA L6-20P 20A 250V 2 HP NEMA L7-20R 20A 277V AC 2 HP NEMA L7-20P 20A 277V AC 2 HP B-22
23 TIST-LOCK Devices 2 Pole, 3 ire rounding 20 Ampere, 125, 250 Volts and 277 Volts AC atertight Safety-Shroud TIST-LOCK System UL Listed, CSA Certified to Type 4, 4, & 12 atertight Safety-Shroud Receptacles, Back ired ray Valox housing & flange. HBL2310S HBL2320S HBL2330S Note: Receptacles only fit boxes listed on Page B-72. atertight Safety-Shroud Connector Bodies Black Valox housing, HBL2313S HBL2323S HBL2333S hite Valox clamps. atertight Safety-Shroud Plugs Black Valox housing, HBL2311S HBL2321S HBL2331S hite Valox clamps. atertight Safety-Shroud Flanged Inlets ray Valox housing and flange. HBL2315S HBL2325S HBL2335S Notes: Only receptacles and plugs 480V AC or less are HP rated. *Also suitable for 208V. HP ratings are AC only. Cord grip range for plugs and connector bodies (9 24), #16-3 Type SJ to #8-3 Type S, SO. For technical information see page B-84. CIRCUIT-LOCK Unfused Safety-Shroud Mechanical Interlock for Twist-Lock Receptacles Mechanical Interlock accommodates HBLMITL** 20A and 30A watertight safety-shroud receptacles. Note: **Not shown, see pages B-64 and B-65 for details. NEMA L5-20R 20A 125V 1 HP NEMA L5-20P 20A 125V 1 HP Valox is a registered trademark of eneral Electric Company. NEMA L6-20R 20A 250V 2 HP* NEMA L6-20P* 20A 250V 2 HP* IP66 SUITABILIT NEMA L7-20R 20A 277V AC 2 HP NEMA L7-20P 20A 277V AC 2 HP 3.75" (95.3) 2.56" (65.0) 2.78" (70.6) 3.75" (95.3) 3.75" (95.3) 2.69" (68.3) HBL2320S 4.38" (111.1) HBL2323S 4.50" (114.3) HBL2321S 2.28" (57.9) 3.75" (95.3) HBL2325S 1.50" (38.1) 1.63" (41.4) Locking Devices 2P 3, 20A, 125V, 250V and 277V AC B-23
24 2P 3, 20A, 125V, 250V and 277V AC Locking Devices TIST-LOCK Devices 2 Pole, 3 ire rounding 20 Ampere, 125, 250 Volts and 277 Volts AC Safety-Shroud TIST-LOCK System 2.26" (57.4) 2.04" (51.8) 5.12" (130.0) 2.88" (73.2) HBL2320AR 4.56" (115.8) 5.12" (130.0) HBL2320SR2 3.86" (98.0) 3.14" (79.8) HBL " (40.1) 2.84" (72.1) HBL2320SR.77" (19.6) 3.97" (100.8) HBL2321S 4.57" (116.1) 1.97" (50.0) 2.26" (57.4) Safety-Shroud Twist-Lock Receptacles, Back ired Angle housing one gang. HBL2310AR HBL2320AR HBL2330AR Surface mounting one gang. HBL2310SR HBL2320SR HBL2330SR Semi-flush two gang. HBL2310SR2 HBL2320SR2 HBL2330SR2 Notes: See page B-72 for box mounting application. Housing and flange, gray Valox. IP20 SUITABILIT Insulgrip Connector Bodies Black and white nylon. HBL2313 HBL2323 HBL2333 Note: Cord grip range (9-24). IP20 SUITABILIT Safety-Shroud Male Plugs NEMA L5-20R 20A 125V 1 HP Black and white nylon body, HBL2311S HBL2321S HBL2331S white Valox shroud. Note: Cord clamp range (9-24). Insulgrip Flanged Inlets Nylon casing, back wired. HBL2315 HBL2325 HBL2335 Note: Only receptacles and plugs 480V AC or less are HP rated. *Also suitable for 208V AC. HP ratings are AC only. For technical information, see page B-83. Valox is a registered trademark of eneral Electric Company. NEMA L5-20R 20A 125V NEMA L5-20P 20A 125V 1 HP NEMA L5-20P 20A 125V NEMA L6-20R 20A 250V 2 HP* NEMA L6-20R 20A 250V NEMA L6-20P* 20A 250V 2 HP* NEMA L6-20P 20A 250V 2 HP NEMA L7-20R 20A 277V AC 2 HP NEMA L7-20R 20A 277V AC NEMA L7-20P 20A 277V AC 2 HP NEMA L7-20P 20A 277V AC 2 HP B-24
25 TIST-LOCK Devices 2 Pole, 3 ire rounding 20 Ampere, 125, 250 Volts and 277 Volts AC VALISE Plugs and Connector Bodies IP20 SUITABILIT Valise Plugs Cord Dia. ellow nylon HBL2311V HBL2321V HBL2331V ( ) Corrosion resistant, HBL23CM11V yellow nylon. ( ) Black nylon HBL2311VBK HBL2321VBK HBL2331VBK ( ) Valise Connector Bodies NEMA L5-20P 20A 125V 1 HP Cord Dia. ellow nylon HBL2313V HBL2323V ( ) Black nylon HBL2313VBK HBL2323VBK HBL2333VBK ( ) Notes: Connector bodies are not HP rated. HP ratings are AC only. See page B-88 for technical information. eatherproof Accessories IP55** SUITABILIT ellow Seal-Tite elastomer triple seal cover for use with Valise HBL60CM31V* plugs when used in cord set and Valise connector bodies when used with flanged inlet. ellow Seal-Tite elastomer triple seal cover for use with HBL60CM32V* Valise connector bodies. Note: **hen installed and used properly with plug and connector body combinations. * Not UL Listed, CSA Certified NEMA L5-20R 20A 125V NEMA L6-20P 20A 250V 2 HP NEMA L6-20R 20A 250V NEMA L7-20P 20A 277V AC 2 HP NEMA L7-20R 20A 277V AC 1.78" (45.2) 1.78" (45.2) 2.50" (63.5) HBL2311V 2.60" (66.0) HBL2313V HBL60CM31V HBL60CM32V Locking Devices 2P 3, 20A, 125V, 250V and 277V AC B-25
26 2P 3, 20A, 347V AC, 480V AC and 600V AC Locking Devices TIST-LOCK Devices 2 Pole, 3 ire rounding 20 Ampere, 347, 480 and 600 Volts AC Receptacles, INSULRIP Connector Bodies, Flanged Devices and Plugs 2.26" (57.4) 1.97" (50.0) 2.67" (67.8).98" (24.9) " (4.8).19" 120 (4.8) 1.70" (43.2) HBL " (98.0) HBL " (73.2) 2.04" (51.8) HBL2346 HBL " (73.2) " (69.9) " (51.8) HBL " (31.2) 1.56" 2.38" (39.6) (60.5) (83.3) 3.28" #6-32 TAP 2.09" (53.1) 1.25" R (31.8) 2.09" (53.1) 1.25" R (31.8) 1.97" (50.0) 2.26" (57.4) Single Flush Receptacles, Back and Side ired Isolated ground, orange nylon face. I2340 Insulgrip Connector Bodies Black and white nylon. HBL3723 HBL2343 HBL2353 Note: Cord clamp range (9-24). Insulgrip Flanged Receptacles Nylon casing, back wired. HBL3726 HBL2346 HBL2356 Insulgrip Plugs NEMA L8-20R 20A 480V AC 3 HP Black and white nylon. HBL3721 HBL2341 HBL2351 Notes: Cord clamp range (9-24). See page B-73 for Add-A-Shroud kit. Insulgrip Flanged Inlets Nylon casing, back wired. HBL3725 HBL2345 HBL2355 Notes: Only receptacles and plugs up to 480V AC are HP rated. For technical information see page B-83. See pages B-68 and B-69 for accessories. See page B-63 for switched enclosure. HP ratings are AC only. NEMA L9-20R 20A 600V AC NEMA L24-20R 20A 347V AC Black nylon face. HBL3720 HBL2340 HBL2350 IP20 SUITABILIT IP20 SUITABILIT NEMA L8-20P NEMA L24-20P 20A 480V AC 20A 347V AC 3 HP NEMA L9-20P 20A 600V AC B-26
27 TIST-LOCK Devices 2 Pole, 3 ire rounding 30 Ampere, 125, 250 Volts and 277 Volts AC Receptacles, INSULRIP Connector Bodies, Flanged Devices and Plugs Single Flush Receptacles, Back and Side ired Black nylon face. HBL2610 HBL2620 HBL2630 Isolated ground, orange nylon face. I2610 I2620 Corrosion resistant, yellow nylon face. HBL26CM10 Insulgrip Connector Bodies Black and white nylon. HBL2613 HBL2623 HBL2633 Heat stabilized, gray nylon, 220 F (104 C). HBL2613F HBL2623F Corrosion resistant, yellow nylon. HBL26CM13 HBL26CM23 Note: Cord clamp range (9-24). Insulgrip Flanged Receptacles Nylon casing, back wired. HBL2616 HBL2626 HBL2636 Heat stabilized, gray nylon, 220 F (104 C). HBL2616F HBL2626F Insulgrip Plugs IP20 SUITABILIT Black and white nylon. HBL2611 HBL2621 HBL2631 Heat stabilized, gray nylon, 220 F (104 C). HBL2611F HBL2621F Corrosion resistant, yellow nylon. HBL26CM11 HBL26CM21 Notes: Cord clamp range (9-24). See page B-73 for Add-A-Shroud kit. Insulgrip Flanged Inlets Nylon casing, back wired. HBL2615 HBL2625 HBL2635 Heat stabilized, gray nylon, 220 F (104 C). HBL2615F HBL2625F Notes: All HP ratings are AC only. Only receptacles and plugs are HP rated. For technical information see page B-83. For accessories see pages B-68 and B-69. See page B-63 for switched enclosure. NEMA L5-30R 30A 125V 2 HP IP20 SUITABILIT NEMA L5-30P 30A 125V 2 HP NEMA L6-30R 30A 250V 2 HP NEMA L6-30P 30A 250V 2 HP NEMA L7-30R 30A 277V AC 3 HP NEMA L7-20P 20A 277V AC 2 HP 2.26" (57.4) 1.97" (50.0) 2.67" (67.8).98" (24.9).19" (4.8).19" (4.8) " (43.2) HBL " (98.0) HBL " (73.2) 2.04" (51.8) HBL2626 HBL " (73.2) 2.04" (51.8) 2.75" (69.9) 120 HBL " (31.2) 1.56" 2.38" (39.6)(60.5)(83.3) 3.28" #6-32 TAP " (53.1) 2.09" (53.1) 1.25" R (31.8) 2.26" (57.4) 1.25" R (31.8) 1.97" (50.0) Locking Devices 2P 3, 30A, 125V, 250V and 277V AC B-27
28 2P 3, 30A, 125V, 250V Locking Devices 3.75" (95.3) 2.56" (65.0) 2.78" (70.6) TIST-LOCK Devices 2 Pole, 3 ire rounding 30 Ampere, 125 and 250 Volts atertight Safety-Shroud TIST-LOCK System 3.75" (95.3) 2.69" (68.3) 3.75" (95.3) HBL2610S 4.38" (111.1) HBL2613S HBL2611S 2.28" (57.9) 3.75" (95.3) HBL2615S 1.50" (38.1) 4.50" (114.3) 1.63" (41.4) UL Listed, CSA Certified to Type 4, 4, & 12 atertight Safety-Shroud Receptacles, Back ired ray Valox housing and flange. HBL2610S HBL2620S Note: Receptacles only fit boxes listed on page B-72. atertight Safety-Shroud Connector Bodies Black Valox housing, white Valox clamps. HBL2613S HBL2623S atertight Safety-Shroud Plugs Black Valox housing, white Valox clamps. HBL2611S HBL2621S atertight Safety-Shroud Flanged Inlets ray Valox housing and flange. HBL2615S HBL2625S Notes: Only receptacles and plugs 480V AC or less are HP rated. *Also suitable for 208V. HP ratings are AC only. Cord grip range for plugs and connector bodies (9-24). #16-3 Type SJ to #8-3 Type S, SO. For technical information see page B-84. CIRCUIT-LOCK Unfused Safety-Shroud Mechanical Interlock for Twist-Lock Receptacles Mechanical Interlock accommodates 30A HBLMITL** watertight Safety-Shroud receptacles. Note: **Not shown, see pages B-64 and B-65. Valox is a registered trademark of eneral Electric Company. NEMA L5-30R 30A 125V 2 HP NEMA L5-30P 30A 125V 2 HP IP66 SUITABILIT NEMA L6-30R 30A 250V 2 HP* NEMA L6-30P 30A 250V 2 HP* B-28
29 TIST-LOCK Devices 2 Pole, 3 ire rounding 30 Ampere, 125 and 250 Volts Safety-Shroud TIST-LOCK System Safety-Shroud Twist-Lock Receptacles, Back ired Angle housing one gang. HBL2610AR HBL2620AR Surface mounting one gang. HBL2610SR HBL2620SR Semi-flush two gang. HBL2610SR2 HBL2620SR2 Notes: See page B-72 for box mounting application. Housing and flange, gray Valox. Insulgrip Connector Bodies IP20 SUITABILIT Black and white nylon. HBL2613 HBL2623 Note: Cord clamp range (9-24). Safety-Shroud Male Plug IP20 SUITABILIT Black and white nylon body, HBL2611S HBL2621S white Valox shroud. Note: Cord clamp range (9-24). Insulgrip Flanged Inlets Nylon casing, back wired. HBL2615 HBL2625 Notes: Only receptacles and plugs 480V AC or less are HP rated. *Also suitable for 208V. HP ratings are AC only. For technical information see page B-83. Valox is a registered trademark of eneral Electric Company. NEMA L5-30R 30A 125V 2 HP NEMA L5-30R 30A 125V NEMA L5-30P 30A 125V 2 HP NEMA L5-30P 30A 125V 2 HP NEMA L6-30R 30A 250V 2 HP* NEMA L6-30R 30A 250V NEMA L6-30P 30A 250V 2 HP* NEMA L6-30P 30A 250V 2 HP 2.26" (57.4) 2.04" (51.8) 5.12" (130.0) 4.56" (115.8) 2.88" (73.2) HBL2620AR 5.12" (130.0) HBL2620SR2 3.86" (98.0) HBL " (100.8) 3.14" (79.8) 1.58" (40.1) 2.84" (72.1) HBL2620SR HBL2621S.77" (19.6) 4.57" (116.1) 1.97" (50.0) 2.26" (57.4) Locking Devices 2P 3, 30A, 125V, 250V B-29
Straight Blade Devices Index
Section A Straight Blade Devices Index Product Page Hospital rade Duplex Receptacles... A-3 Duplex, Illuminated Face, Tamper Resistant and Isolated round... A-4 SNAPConnect, Single and 4-PLEX... A-5 Plugs,
More informationAdvAntAge SerieS Switch-rAted iec Pin And Sleeve
AdvAntAge SerieS Switch-rAted iec Pin And Sleeve now AvAilAble in 30 & 60 AmP Highest Performing IEC Pin and Sleeve Connections for the Most Demanding Environments Hubbell s Pin and Sleeve connections
More informationArktite Heavy Duty Circuit Breaking Plugs and Receptacles
1312-1313.qxp 12/16/2013 7:04 PM Page 1312 Arktite Heavy Duty Circuit Breaking Plugs and Receptacles Industrial Heavy Duty Non-hazardous Areas Features: Arktite circuit breaking plugs and receptacles are
More informationAMPSEAL* Automotive Plug Connector and Header Assembly
AMPSEAL* Automotive Plug Connector and Header Assembly Application Specification 24 SEP 97 Rev E All dimensions are given in millimeters unless otherwise specified. All dimensional tolerances are +0.2
More informationELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION 26 27 26, PAGE 1 SECTION 26 27 26 WIRING DEVICES
KNOXVILLE, TENNESSEE SECTION 26 27 26, PAGE 1 PART 1 - GENERAL 1.01 DESCRIPTION OF WORK: SECTION 26 27 26 A. The extent of wiring device work is indicated by drawings and schedules. Wiring devices are
More informationCable and Cord Reels. Section R. Cable and Cord Reels Index. Index
Section R Index Product Page Number and R-2 3 Weatherproof Cable and Static Discharge Reels R-4 R-5 R-6 Index www.hubbell-wiring.com and and Hubbell Electric Cord and Cable Reels Hubbell Wiring Device
More informationPLUGS & RECEPTACLES. INNOVATIVE EXPLOSION PROTECTION by R. STAHL 1-800-782-4357
Series Features: Color coding and pin configuration makes it physically impossible to mate plugs and receptacles of different voltages and current ratings (per IEC 60 309-2). Interlocked switch mechanism
More informationTMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations
TMC CableReady Connectors For Jacketed Metal Clad Cable TMC For Non-Hazardous Locations CableReady connectors are designed for use with the following cables: Type MC jacketed corrugated aluminum, interlocked
More informationLIEBERT VNSA Installation Sheet
LIEBERT VNSA Installation Sheet Description The Liebert vnsa network switch is designed for connecting multiple Ethernet-ready devices and comes in various models. The unit may have: A Liebert icom display
More informationRMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions
Heat-Tracing Remote Monitoring Module for the NGC Control System Installation Instructions Tools Required 3 mm slotted screwdriver 3/8 hex key (for -4X only) Approvals Nonhazardous locations Type NM LISTED
More informationThe Different Types of AC Power Connectors in North America
The Different Types of AC Power Connectors in North America White Paper #20 Executive Summary A confusing array of AC power plugs and receptacles exist to deliver power to various electronic loads. This
More informationScepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" We build tough products for tough environments Standing Still is Not an Option. We re proud to introduce the NEW
More informationRugged & Reliable Power Connections
Rugged & Reliable Power Connections featuring: DECONTACTOR TM Series Switch Rated Plugs & Receptacles High Amperage Plugs & Receptacles Multipin Connectors Benefit from Meltric Plugs, Receptacles, and
More informationD e s c r i p t i o n a n d De s i g n Fe a t u r e s
R igp o w e r RMP II Se r i e s R igp o w e r RMP II Se r i e s D e s c r i p t i o n a n d De s i g n Fe a t u r e s RigPower, LLC s mission is to create new industry standards in industrial electrical
More informationMini USB and USB 2.0-IP67 Connector System
Mini USB and USB 2.0-IP67 Connector System Section 12 Mini USB and USB 2.0-IP67 Connector System CONEC has added the Mini-USB connector. This Mini-USB IP67 receptacle and plug family, feature a bayonet
More informationScepter PVC Molded Junction Boxes
Scepter PVC Molded Junction Boxes TM ELECTRICAL SYSTEMS PVC MOLDED JUNCTION BOXES 4" to 12" Fully Certified: NEMA, UL & CSA We build tough products for tough environments Standing Still is Not an Option.
More informationpicomax The Pluggable Connection System
picomax The Pluggable Connection System TECHNOLOGY THIS SPECIALIZED CAN T MEET ALL REQUIREMENTS. YES IT CAN. CONTENTS picomax Pin spacing: 3. mm/0.138 in;.0 mm/0.197 in; 7. mm/0.29 in Versatile Pluggable
More informationUniversal MATE-N-LOK Connector System
Universal MATE-N-LOK Connector System 2011 Tyco Electronics Corporation. All Rights Reserved. MATE-N-LOK, TE Connectivity, TE Connectivity (logo) and TE (logo) are trademarks. Other logos, products and/or
More information* Please visit the product pages on our website for the most up-to-date product information. Con-X Molded Cable Assembly Checklist...
TABLE OF CONTENTS Custom Molded Cable Assemblies and Connectors..........................2 Capabilities.....................................................................3 Standard Connector Products.......................................................4
More informationELECTRIC METERING COMMERCIAL & INDUSTRIAL
ELECTRIC METERING COMMERCIAL & 1.0 INDEX 1.0 INDEX 2.0 SCOPE 3.0 GENERAL REQUIREMENTS 4.0 METER LOCATIONS 5.0 UNDERGROUND TERMINATIONS 6.0 METERING TRANSFORMER ENCLOSURES 7.0 SINGLE CUSTOMER METER INSTALLATIONS
More informationUniversal MATE-N-LOK Connectors
Product Facts Pins and sockets can be intermixed in the same housing Positive polarization Rear cavity identification completely enclosed in housings Positive locking housings Insulation capability to.00
More informationIEC 309 INTERLOCKS NORTH AMERICAN
IEC 309 INTERLOCKS NORTH AMERICAN SWITCH VERSION with MCB (Circuit Breakers) 20, 30, 60 Amp NEMA 4X Watertight (IP67) Drawing A (See Drawing on Specification Page) 20, 30, 60 Amp Spashproof (IP44) Drawing
More informationVOYAGER 570G. 744A Sprayer Control
VOYAGER 570G 744A Sprayer Control U S E R M A N U A L U S E R M A N U A L Table of Contents CHAPTER 1 - INTRODUCTION...1 SYSTEM CONFIGURATIONS...1 KIT CONTENTS...3 CONTROL HOUSING ASSEMBLY...5 CHAPTER
More informationAmphenol C 091 A/B/D. Circular Connectors. Amphenol-Tuchel Electronics GmbH
Amphenol C 091 A/B/D Circular Connectors Amphenol-Tuchel Electronics GmbH C 091 A Main Features Metal threaded coupling acc. to IEC. Number of contacts are 2 to 8, 12 and 14. Internal metal strain relief
More informationThe Different Types of AC Power Connectors in North America
The Different Types of AC Power Connectors in North America White Paper 20 Revision 1 by James Spitaels > Executive summary A confusing array of AC power plugs and receptacles exist to deliver power to
More informationC O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S
C O N V E Y O R C O M P O N E N T S C H A I N S B E L T S B E A R I N G S January 2009 Issue 6 Valu Guide Brackets The Ultimate in Adjustability and Cost Savings Valu Guide brackets are part of a family
More informationLighting Packages. 230 VAC Fluorescent Enclosure Light:
Spec-00581 H763.422.2211 763.422.2600 Electrical Lighting Packages Electrical Lighting Packages PANELITE Enclosure Lights Overview FEATURES Slim profile allows light to be tucked up out of the way for
More informationQuick Connect Boxes Inside Gloveboxes
ULC Series Junction Boxes Quick Connect Boxes Inside Gloveboxes The ULC quick connect junction boxes are the essential elements to optimize the cabling inside gloveboxes. Large range Designed for nuclear
More informationPlugs and Receptacles
Plugs and Receptacles Industrial Heavy Duty Interlocked Application and Selection Applications: Where extra protection is a requirement; interlocked units provide dead front receptacles; connection cannot
More informationELECTRICAL CONNECTORS
ELECTRICAL CONNECTORS 07-09 00-09 04-09 99-09 116 ELECTRICAL CONNECTORS LIGHT POWER MODULES WORKS WITH STANDARD & LED BULBS! WORKS WITH STANDARD & LED BULBS! CALL US TODAY FOR YOUR MODULITE VEHICLE APPLICATION
More informationAMP Standard Terminals and Splices. RoHS. Ready
AMP Standard Terminals and Splices RoHS Ready Table of Contents Product Facts Solderless terminals and splices performs up to today s standards for reliable termination in applications ranging from control
More informationUtility Distribution Systems
Utility Distribution Systems 6/2012 A0011037 1 WARRANTY This equipment is warranted to be free from defects in materials and workmanship, under normal use and service, for a period of 12 months from date
More informationBERTHOLD ELECTRIC GENERATOR CONNECTION CABINET
BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET Berthold Electric Company s Generator Connection Cabinet provides a quick and convenient station to connect a portable generator to a facility s main service
More informationHIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015
HIROSE ELECTRIC U.S.A. Fiber Optic VAR July, 2015 Fiber Optic VAR Program Hirose Launches Fiber Optic Cabling VAR Program to provide a complete fiber optic cable assembly and wire harness solutions to
More informationOutdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series
COMPONENTS PRODUCT INFORMATION RoHS Compliant NEW Outdoor Use Waterproof I/O Connectors (Optical / Modular / Electrical) FO-BH, FO-BC, NT5, JN2 / W Series Optical FO-BH Series (Compact Type) CONNECTOR
More informationHP UPS R1500 Generation 3
HP UPS R1500 Generation 3 Installation Instructions Part Number 650952-001 NOTE: The rating label on the device provides the class (A or B) of the equipment. Class B devices have a Federal Communications
More informationTRAILER WIRING AND COMMUNICATION SYSTEMS Systèmes de Communication et Filage de Remorques Sistemas de Comunicación y Cableado para Caravanas
162 Ultra-Pin Receptacle, Two Hole Mount Redundant ground through frame No rust, die-cast zinc Heavy bosses for extra rigidity Barrel slanted to drain moisture Mounting holes slotted for universal fit
More informationGenerator DoCKInG StatIonS
Generator DOCKING STATIONS TRYSTAR Portable Power Cable Cam to cam cable extensions 2000V, 100A-400A rated to NEC table 400.5 (B) All portable power cable sold is highly flexible and UL & C-UL or CSA Listed
More informationUSA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com. Electrical Industrial and Fleet Solutions
USA: 866.LAWSON4U (866.529.7664) Canada: 800.563.1717 lawsonproducts.com Electrical Industrial and Fleet Solutions Lawson's ELECTRICAL SOLUTIONS Electrical Wire Low voltage (60V) and high voltage (300/600V)
More informationMueller. Pipe Repair Products. Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source.
Mueller Pipe Repair Products Saddles Tapping Sleeves Pipe Repair Clamps A complete selection for all types of pipe... all from a single source. SERVICE SADDLES Mueller service saddles, available in bronze,
More informationSlimSeal SSL Connector. Now Available in 1 Position. Free Hanging Version
Now Available in 1 Position Free Hanging Version SlimSeal SSL Connector The SlimSeal SSL connectors are low profile, single row connectors developed for indoor and outdoor LED lighting applications. These
More informationTERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246
TERMINATION EQUIPMENT INSTRUCTION MANUAL TELE-PIERCE P/N 356-246 OPERATION AND SERVICE INSTRUCTIONS AMPHENOL 157 SERIES TELE-PIERCE MULTI-WIRE TERMINATION TOOL 356-246 AMPHENOL TERMINATION SYSTEMS 1830
More informationSeries 8146/5-V37 and Series 8150/5-V37
www.stahl.de > Clear assignment safe technology easy installation > Intelligent structure only one rotary actuator for frequency-controlled drives ) 20 ms leading auxiliary contact for safe motor disconnection
More informationInstallation Instructions For Slider Casement Air Conditioners
Installation Instructions For Slider Casement Air Conditioners NOTE: These instructions describe installation in a typical wood framed window with a wood SLIDE-BY sash, or installation in a metal CASEMENT
More informationgesis IP + Heavy Duty Class I, Zone 2
gesis IP + Heavy Duty gesis IP+ 20i HD Z2 Heavy-Duty Connectors for Class 1, Zone 2 Hazardous Locations Catalog 2012 Catch the Next Wave in Modular Connections Plug & Go Heavy-Duty Connectors for areas
More informationExpress5800/120Ed. Rack Mount Kit Installation Procedures PN: 455-01607-001
Express5800/120Ed Rack Mount Kit Installation Procedures PN: 455-01607-001 Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials,
More informationAnderson Power Products
Anderson Power Products Anderson Power Products APP s philosophy is to provide products and services within the trading markets of our customers. We currently serve our world-wide customer base from customer
More informationArecont Vision H.264 Color or Day/Night SurroundVideo Series Installation Manual
0 P a g e H.264 Color or Day/Night SurroundVideo Installation Manual Inside the box: A. Arecont Vision SurroundVideo camera B. Mounting template C. RJ45 female to female coupler D. Hex key E. Security
More informationMetallic and Non-Metallic Air Conditioning Disconnects. A Complete Family of. Disconnects with Exclusive Time Saving Features
Metallic and Non-Metallic Air Conditioning Disconnects A Complete Family of Disconnects with Exclusive Time Saving Features Enclosed Molded Case Disconnect Switch Not-Fusible The preferred molded case
More informationAdvantium 2 Plus Alarm
ADI 9510-B Advantium 2 Plus Alarm INSTALLATION AND OPERATING INSTRUCTIONS Carefully Read These Instructions Before Operating Carefully Read These Controls Corporation of America 1501 Harpers Road Virginia
More informationArbiter Systems Test Leads: Engineered for Optimum Performance and Safety
Arbiter Systems Test Leads: Engineered for Optimum Performance and Safety Arbiter Systems, Inc. test equipment offers outstanding performance, flexibility, and value. Our test leads offer nothing less.
More informationDirectory chapter 04
M Directory chapter 04 D-Sub Mixed subminiature D connectors New Page D-Sub mixed connector system general information................... 04.02 Contact arrangements............................................
More informationNavico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement
Navico-Northstar 2kW JRC Radar Package, Scanner Cable Removal and Replacement This work instruction describes the methods and means for which to remove and reinstall optional scanner cable configurations
More information14 PHOENIX CONTACT Courtesy of Power/mation. 1310 Energy Lane, Saint Paul, MN 55108. info@powermation.com - 800-843-9859 - www.powermation.
14 PHOENIX CONTACT PLUSCON circular is a circular connector for use in industrial automation. The range of design sizes available is varied, starting with the design sizes M5 to M8 and M1, for sensor/actuator
More informationPAM Connectors. PAM Bayonet Connectors
PAM Bayonet Tel : 33 (0)1 60 84 21 40 Fax : 33 (0)1 60 84 43 81 info@bernier.tm.fr www.bernier.tm.fr Overview Miniature audio connectors with bayonet locking system, equipped with 07 or 10 contacts, and
More information25-kV Apparatus Bushings B Series (bolt-in) for Elbow to Air-Insulated Service 200 Amp, 600 Amp and 1250 Amp
Page 1 2015 Grounded Metal Equipment Plate Equipment Connection Bus Bar or Other Component 15 kv or 25 kv Separable Insulated Connector (elbow) Equipment Connection Power Cable Power Cable Grounded Metal
More informationMETER REQUIREMENTS GENERAL REQUIREMENTS SECTION D
12 - ELECTRIC SERVICE HANDBOOK SECTION D METER REQUIREMENTS This chapter gives you information on Central Lincoln s metering requirements. It's divided into three sections: General requirements This section
More informationELECTRIC KNIFE SHARPENER
PRODUCT MANUAL- M109 MODEL 401 ELECTRIC KNIFE SHARPENER Please read thoroughly before operation and keep for future reference Model 401 Knife Sharpener Specifications Model No. #401 Power Requirements
More informationRAY-MAX Integrated Solar Power Strip
RAY-MAX Integrated Solar Power Strip 600008, 600009, 600010, 600208, 600209, 600210 Owner s Manual NEXTRONEX, INC. Revision Date: 10/27/14 Contents 1. Safety Instructions... 3 2. General Equipment Warnings...
More informationCustom Cable Assemblies for Medical Applications and more.
Custom Cable Assemblies for Medical Applications and more. National Cable Molding is one of the United States premier suppliers of custom molded electrical assemblies for medical applications. Our capability
More information5800 Temperature Sensor Cable Assembly
5800 Temperature Sensor Cable Assembly Removal and Replacement Instruction Sheet #60-4702-070 Revision D, January 14, 2013 Overview The 5800 has two refrigeration temperature sensors, one attached to the
More informationPump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling
Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling 250_P1 R10/7/2015 Copyright 2015 Liberty Pumps Inc. All rights reserved. Specifications subject to change without notice.
More informationINSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks
Securitron Magnalock Corp. www.securitron.com ASSA ABLOY, the global leader Tel 800.624.5625 techsupport@securitron.com in door opening solutions INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate
More informationMicrio WS1 Replacement Wind Speed Sensor and WC1 Replacement Wind Compass Sensor for Raymarine ST50 and ST60 Wind Instruments. Rev 4.
Micrio WS1 Replacement Wind Speed Sensor and WC1 Replacement Wind Compass Sensor for Raymarine ST50 and ST60 Wind Instruments. Rev 4.1 The Micrio WS1 Wind Speed Sensor and WC1 Compass Sensor are direct
More informationAutoDome Easy II. VEZ Series. Mounting Manual
AutoDome Easy II VEZ Series en Mounting Manual AutoDome Easy II Table of Contents en 3 Table of Contents 1 Important Safety Instructions 5 2 Unpacking 7 2.1 Parts List 7 3 Description 9 4 Installing a
More informationDirectory chapter 02 - DIN Power (to 6 A) Types D, E, F, FM, 2F, F9, interface connectors I/U 02. 01. Technical characteristics types D and E... 02.
Directory chapter 02 - () Types D, E, F, FM, 2F, F9, interface connectors I/U Page Technical characteristics types D and E.............................. 02.10 Type D connectors.................... 02.11
More informationWiser Panel Meter, Model Number WISERCTPM200 Installer s Guide
Instruction Bulletin EAV85226 08/2014 Wiser Panel Meter, Model Number WISERCTPM200 Installer s Guide Retain for future use. Product Description Kit Contents The Wiser Panel Meter is for use in energy management
More informationTesting Accessories. Test PaddleS. Insulated Socket Wrench Jumper Strips Test Lead Kit. Test Paddle Attachment Clips Plugs Binding Posts
Testing Accessories Test Paddles Test Paddle Attachment Clips Plugs Binding Posts Insulated Socket Wrench Jumper Strips Test Lead Kit Test PaddleS The 10 and 14 pole potential test paddles are feature
More informationINSTALLATION INSTRUCTION SPEC. SHEET 7/00. City of New York Calendar #40747 ETL LISTED UNDER U.L. STD. 2108 LOW VOLTAGE TRACK LIGHTING SYSTEM
7/00 INSTALLATION INSTRUCTION SPEC. SHEET 99052 99063 City of New York Calendar #40747 Copyright c 2000 ALFA Lighting, Inc. All rights reserved. Call:1-415-975-8080 QUICK JACK QJS R LISTED 9901483 ETL
More information3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE
4 3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE A. Changing the Control Board B. Replacing a Heating Element C. Thermistor Replacement D. High Limit Switch Replacement E. Level Detector Replacement
More informationTriac Printed Circuit Board Replacement
Technical Service Bulletin: Triac Printed Circuit Board Replacement TRONIC 5000C Pro Models: WH17, WH27, WH36 Introduction Fig. 1 ELECTRICITY IS EXTREMELY DANGEROUS. TAKE EXTRA PRECAUTIONS AND ENSURE ALL
More informationLU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions
LORTONE LU6X-130 Item # 061-092 LU6X Basic Item # 061-090 LU6X-130 Instructions and Parts List (including LU6X Basic) Operating Instructions Introduction The LU6X is one the most versatile pieces of equipment
More informationNEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series. Quick Install Guide
NEI-30 VEI-30 Dinion Infrared Imager NEI VEI Series en Quick Install Guide NEI-30 VEI-30 Dinion Infrared Imager Table of Contents en 3 Table of Contents 1 Planning 4 1.1 Hardware Requirements 4 1.2 Pre-installation
More informationElectrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016. Underground branch circuit feeding a detached garage:
Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, 2016 * Garage construction requires permits (electrical, building) * Permits must be applied for at the time. * Dial
More informationBUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS
BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS PLEASE READ COMPLETE INSTRUCTIONS BEFORE YOU BEGIN LEAVE INSTALLATION INSTRUCTIONS AND USER'S GUIDE WITH OWNER ALL ELECTRIC WIRING AND PLUMBING MUST BE DONE
More informationAll work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.
DIVISION 16 ELECTRICAL SECTION 16100 - ELECTRICAL PART 1 - GENERAL SCOPE All electrical work as shown on the drawings and as necessary to provide a complete electrical system. Include primary service,
More informationInstallation Instructions
READ BEFORE INSTALLING UNIT For Slider Casement Air Conditioners To avoid risk of personal injury, property damage, or product damage due to the weight of this device and sharp edges that may be exposed:
More informationWaterproof Connectors for Outdoor Use
Waterproof Connectors for Outdoor Use HR41A Series Mated condition diagram Nut-tightening rear mount type (panel thickness=mm) 70.5 Features 1. Waterproof connector designed for outdoor use Light-weight
More informationStandard Buccaneer - Ethernet
IP6 rated compliant PUR jacket on cable Shielded system shielded coupler Shroud on RJ45 Screw coupling Rewireable flex connector PCB mounted panel connector IDC termination panel connector Earth lead version
More informationULTIMATE SNAP-N-SEAL
ULTIMATE SNAP-N-SEAL F Series Compression Connectors Thomas & Betts introduces the Ultimate Snap-N-Seal Compression Connector, the newest addition to the Snap-N-Seal system. Look for the classic design
More informationNow Available in Black Zinc Nickel
847/848 Series Power Supply up to 63 Now vailable in lack Zinc Nickel The 847/848 bayonet Series has been especially designed for light and harsh environment. Its physical characteristics and performances
More informationLSA-PLUS Series 2 Connection and Disconnection Modules and Accessories
LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories 2015 PRODUCT CATALOG 2ND EDITION LSA-PLUS Series 2 Connection and Disconnection Modules and Accessories A technically and commercially
More informationAnderson Powerpoles. Powerpole Assembly Instructions for SCOUT, NAVIGATOR AND RANGER ROV s
Anderson Powerpoles Powerpole Assembly Instructions for SCOUT, NAVIGATOR AND RANGER ROV s Anderson Powerpoles Power Connections NEW in 2016!!! ELEC-010E: Power supply connections will be Red/Black Anderson
More informationTS93 EMR T/PT/TDE. Surface applied door closer
TS EMR T/PT/TDE Surface applied door closer Installation instructions: Pull side track mount door closer with smoke detector (EMR T) Push side track mount door closer with smoke detector (EMR PT) Double
More informationJumper bar BJM. Assembled jumper bar BJD. Assembled jumper bar
BJ Jumper bar Use the BJ jumper bar to connect consecutive and nonconsecutive terminal blocks with the same spacing. Two types of jumper bars are available : an assembled unit and a nonassembled unit.
More informationFront axle components, overview
just a test. Front axle components, overview 40-1 General Information Load bearing components and parts of the suspension must not be welded or straightened. Vehicles without drive axle must not be moved,
More information758 Heavy-duty Ratchet Guy Wire Cutter
INSTRUCTION MANUAL 758 Heavy-duty Ratchet Guy Wire Cutter Read and understand all of the instructions and safety information in this manual before operating or servicing this tool. Register this product
More informationTrillium 40 Axis Spring Tensioner Wire Replacement Instructions
Trillium 40 Axis Spring Tensioner Wire Replacement Instructions 1 Overview The objective is to replace the broken axis spring tensioner wire. This requires the following tasks: 1. Remove the seismometer
More informationAMERBRITE UNDERWATER WHITE LED POOL LAMP
AMERBRITE UNDERWATER WHITE LED POOL LAMP FOR USE ONLY WITH PENTAIR AMERLITE LUMINAIRE INSTALLATION AND USER S GUIDE IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS
More informationSubmit shop drawings for equipment provided under this section Shop drawings shall indicate:
Section 16435 - SWITCHBOARDS Introduction Part 1 - General Reference The work under this section is subject to requirements of the Contract Documents including the General Conditions, Supplementary Conditions,
More informationB. Related Sections: 1. Section 26 05 33 - Raceway and Boxes for Electrical Systems.
SECTION 262726 - WIRING DEVICES PART 1 - GENERAL 1.1 SUMMARY A. Section includes wall switches; wall dimmers; receptacles; multioutlet assembly; and device plates and decorative box covers. B. Related
More informationTrade of Electrician. Three-phase Distribution Boards And Socket Circuits
Trade of Electrician Standards Based Apprenticeship Three-phase Distribution Boards And Socket Circuits Phase 2 Module No. 2.3 Unit No. 2.3.2 COURSE NOTES Created by Charlie Walsh - Athlone TC Revision
More informationSarasota Splash Back Prep and Shine Paint Restorer Inside Front Cover
Caution: Read entire label before using product. Do-It-Yourself PAINT RESTORER KIT Kit Contains: 1-16 oz. Water-based, Biodegradeable Liquid Prep 1-16 oz. Aerosol Shine Spray 1 - Spray Nozzle 2 - Scrub
More informationHorizontal Jet Pumps 1/3-1-1/2 HP
Horizontal Jet s 1/3-1-1/2 FW01 0909 Supersedes 0409 The CPJ, CPH and EK models feature the famous Flint and Walling Service Plus motor, available in either NEMA J or Uni-frame flange construction. The
More informationType 1, 3, & 3R Enclosures
Junction oxes Type 1 Screw over....................................................................... 50-53 Junction oxes Type 1 Hinge over........................................................................
More informationFASTON Terminals and Connectors
Introduction Product Facts Straight, right-angle and receptacle-tab combinations available Receptacles available for 6.3 mm, 4.8 mm and 2.8 mm tab size (.250,.187 and.110 Series) Receptacles mate with
More informationTrident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications
Trident Connector Family Offers the Versatility and Reliability Required in Industrial & Transportation Applications Industrial and transportation applications require robust connections with superior
More informationDTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR. Installation and Operation Manual
DTM04 TANK MONITOR DTM08 TANK MONITOR Dtm12 TANK MONITOR Installation and Operation Manual 1 ENGLISH Safety Instructions 2 Features 2-3 Specifications 3 Installation 4-5 Wiring Diagrams 6-7 Warranty 8
More informationTitle: Grounding and Bonding Rev-01
Procedure No.: BMEHS-002-012 Page: 1 of 12 Preparer: Owner: Approver: EHS Team Member S/H Manager Site Manager Signed Copy on File Signed Copy on File Signed Copy on File Document Revision Change Table
More informationOperating Instructions
Operating Instructions Series L 000 Cord Reels Model Numbers: L 000 L 0 0 L 0 B L 0 X L 00 L A X L 0 L 0 0 L 00 L 0 L 0 B L 0 0 X L 00 L 0 A L 0 X IMPORTANT Read this manual carefully before installing,
More information