PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8

Similar documents
4 Posiflow Proportional Solenoid Valves

Assisted lift operated 2/2-way solenoid valves Type EV250B

3/2-way Solenoid Valve, direct-acting, NC or NO

SPOOL & SLEEVE VALVES solenoid air operated monostable / bistable function threaded ports G 1/8-G 1/4

type V46, solenoid or pneumatic operated

4/2-Way Pneumatic Solenoid Valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

2.12. page Products for Explosion hazardous Environment

Solenoid valves 2/2-way direct-operated Type EV210A

Electro-pneumatic control valves

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

3/2- and 2/2-way cartridge valve type BVE

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

3/2, 5/2, 5/2 bistable and 5/3 way pneumatic solenoid valve

% ^ ) 0.55 W Low Power Solenoid Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT. 2/2 3/2 4/2 5/2 5/3 SERIES Low Power

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Solenoid valves Type EVU

System 8. ü ( System 8

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

servo-controlled 3-WaY vacuum solenoid valves WiTH

Single sub-base valve

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Proportional pressure regulators VPPE

3/2-way Mini Solenoid Valve

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

3/2-way pneumatic cartridge solenoid valve

POWER PULSE VALVES remote pilot threaded or Quick Mount connection 3/4 to 1 1/2

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

SOLENOID VALVE FOR REFRIGERATING SYSTEMS

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Sporlan V-Series Ruby Seat Solenoid Valves

Line-Mounted Valves L Series

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

SOLENOID VALVES AND PNEUMATIC VALVES

Series 8146/5-V37 and Series 8150/5-V37

STC 3S A Series Solenoid Valves

G1/4 Q8. Standard with biased position

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

High Flow High Pressure Solenoid Valve. Double 3/2 N.C. solenoid valve with manual override

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Directional seated valves type VP 1

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Solenoid/pneumatic valves, Tiger Classic

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Scraper Passage Indicator. Electrical Indicator. Features

Four-Way Valves. Accessories TABLE OF. Rotary and Smart. Actuator Motors

2/2 and 3/2 Way Size 6 Seat Valves

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Series P215PR/RM Direct- and Remote-Mount Pressure-Actuated Condenser Fan Speed Controllers for Single-Phase Motors

3 Port Solenoid Valve

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

Cable Plug acc. to DIN EN , Form A

Position Transducers with Restoring Spring 10, 25, 50, 75, 100 mm TR, TRS Series

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

SQUARE D INDUSTRIAL CONTROL PRODUCTS

Valves. Sub-Base Mounted Valves to ISO 5599/2

OUT. The SF2 series suction filter are designed for reservoir side-wall applications. This completely new design of filter allows the filter

zamak nitrile rubber self-extinguishing technopolymer aluminum

Pressure monitoring equipment for oil-sf 6. bushings, type GOEK

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Mustang Series PRESSURE REDUCING CONTROL VALVE WITH PRESSURE SUSTAINING FEATURE. M115-2 (Globe) M (Angle) Schematic. Standard Components

Terminal Boxes Series 8146

Plastic tube flowmeters Series PT/PS

Solenoid Valve Type 3962

3/2 Solenoid Cartridge Valve, Size 6

Solenoid Valve Island Type 3965

PRESSURE REDUCING CONTROL VALVE

On-off valves MS-EM/EE, MS series, NPT

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

SOLENOID VALVES 3-4 WAY

Telephone- and leased line modem for industrial applications TD-36

size size

CompactLogix Power Supplies Specifications

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

How To Build A Low Voltage Capacitor Lvcp

Explosion-Proof Electric Unit Heaters

Ammeter / Voltmeter Series 8402, 8403, 8405, 8404

Linear Luminaire with LED Series EXLUX 6402/2

Solenoid Valves 3- & 4-way valves for actuator control

C 50 μm filtered air, with or without lubrication spool 10 bar G/18 G1/4 6,5 8,5 890

Chapter 5: Flow Valves

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

RY2 miniature industrial relays

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

SICONT Limit Switches Type 3SE3 upto 500 VAC, 600 VDC, 10A

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

Chapter 6: Check Valves

How To Use A Flowmeter

Mini USB and USB 2.0-IP67 Connector System

Compact pressure switch Flameproof enclosure Ex d Model PCA

3 Port Solenoid Valve

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Transcription:

PILOT VALVE BOXES containing 2 to 12 valves 2/2 normally closed, direct operated 1/8 NC OUT IN 2/2 Series 110 EATURES Compact pilot boxes with direct operated, integrated pilot valves Especially designed for the remote control of pulse valves (series 353) Valve seats are integrated in base plate Common exhaust connection for just 1 or 2 (G 3/8") silencers Builtin heating elements for trouble free operation at low ambient temperatures Degree of protection: IP 65 acilities for integrated quick fittings The components satisfy all relevant EC directives General Differential pressure (PS) Response times 0 to 8,5 bar [1 bar = 100kPa] 5 25 ms fluid temperature range (TS) seal material air 20 to +80 C NBR (nitrile) X003GB2009/R8 CONSTRUCTION Baseplate Anodised aluminium Cover ABS (polysterene) UV stabilized Core tube Brass Core and plugnut Spring Disc NBR (nitrile) Shading coil Copper Coil insulation class Electrical connection Spades according to DIN 46244 ELECTRICAL CHARACTERISTICS Standard voltages DC (=) 24V AC () 24V 115V 230V/50Hz coil type nominal power ratings ambient inrush holding cold temperature protection = range (2) (VA) (VA) (W) (W) ( C) UCM22I (1) 20,4 14 10 22 SPECIICATIONS of pilot valves 2 3 4 5 6 7 8 9 10 11 12 pipe G orifice (mm) flow coefficient Kv (m 3 /h) (l/min) 40 to +85 moulded operating pressure differential (bar) maximum (PS) min. air (1) Intermittent duty, Relative Duty Time is 10%. Max on time is 1 min. (2) Minimum ambient temperature without heating elements : 0 C Minimum ambient temperature with 1 heating element : 40 C (2 to 6 pilots) : 15 C (7 to 12 pilots) Minimum ambient temperature with 2 heating elements : 40 C (7 to 12 pilots) (3) Heating element(s) 220240 VDC / VAC 5060 Hz standard, for other voltages see ordering information. Heating element(s) rating 80 watt each. /= 1/8 3,6 0,35 5,8 0 8,5 1/8 3,6 0,35 5,8 0 8,5 without heating S G110A020 S G110A030 S G110A040 S G110A050 S G110A060 S G110A070 S G110A080 S G110A090 S G110A100 S G110A110 S G110A120 catalogue for the boxes (2) 1 heating element (3) S G110A021 S G110A031 S G110A041 S G110A051 S G110A061 S G110A071 S G110A081 S G110A091 S G110A101 S G110A111 S G110A121 2 heating elements (3) S G110A072 S G110A082 S G110A092 S G110A102 S G110A112 S G110A122 X00329

PILOT VALVE BOXES SERIES 110 OPTIONS Pilot boxes with metal cover for harsh conditions and dust approved to ATEX heavy duty applications (prefix: WP) Integrated quick fittings for 6 or 8 mm tubes Special customer adapted executions INSTALLATION The pilot boxes can be mounted in any position without affecting operation Pipe connections are: G 1/8 according to ISO 228 for pilot connection G 3/8 according to ISO 228 for common exhaust Cable entries: control cable on box with 2 6 pilot valves : cable Ø 10 14 mm control cable on box with 7 12 pilot valves : cable Ø 13 18 mm connection cable heating element : cable Ø 5 10 mm Installation/maintenance instructions are included with each pilot box Spare parts kit and replacement coils are available DIMENSIONS (mm), WEIGHT (kg) ORDERING INORMATION (WP) S G110 A 12 0 230/50 Volts/ Hz Optional execution 0 = no heating element 1 = 1 heating element 230V/50Hz 2 = 2 heating elements 230V/50Hz 3 = 1 heating element 24V DC 4 = 2 heating elements 24V DC 5 = 1 heating element 115V/50Hz 6 = 2 heating elements 115V/50Hz 2 Number of pilots 02 = 2 pilot valves 03 = 3 pilot valves etc. (max. 12) 77 3 of pilot valves A B C D E G H J 2 to 6 187 G 1/8 22,5 156 98 26 103 12 27 7 to 12 322 G 1/8 22,5 266 98 26 103 12 27 (1) incl. coil and connector (2) mounting: 2 holes Ø10 with pitch D X00330 K 83 83 Change letter Basic G110 = threaded ports G120 = 6 mm quick fitting + TPL 22467 G130 = 8 mm quick fitting + TPL 22386 Electrical connection spade terminals 6,3 x 0,8 Prefix (optional) WP: Waterproof IP 65 metal enclosure and cover weight (1) 1 2,2 X003GB2009/R8

PILOT VALVE BOXES for explosive atmospheres, zone 22 II 3 D IP65 T85 C to T200 C 2 to 12 valves NC OUT 2/2 Series 110 EATURES Pilot box intended for use in potentially explosive dusty atmospheres, according to Directive ATEX 94/9/EC Compliance with the Essential Health and Safety Requirements has been assured by European Standards EN 50014, EN 5028111 and EN 134631 Containing 2 to 12 valves, 2/2 normally closed, direct operated Common exhaust connection for 1 or 2 (G 3/8") silencers Degree of protection: IP65 acilities for integrated quick fittings The components satisfy all relevant EC directives General Differential pressure (PS) Response times 0 to 8,5 bar [1 bar = 100kPa] 5 25 ms fluid temperature range (TS) seal material air 20 to +80 C NBR (nitrile) CONSTRUCTION Baseplate Anodised aluminium Cover Aluminium Core tube Brass Core and plugnut Spring Disc NBR (nitrile) Shading coil Copper Coil insulation class Electrical connection Spades according to DIN 46244 ELECTRICAL CHARACTERISTICS Standard voltages DC (=) 24V; AC () 24V 115V 230V/50Hz coil type nominal power ratings ambient inrush holding cold temperature protection = range (2) (VA) (VA) (W) (W) ( C) UCM22I (1) 20,4 14 10 22 40 to +75 moulded X003GB2009/R8 TEMPERATURE CLASSIICATION TABLES AC () Solenoids power level (watt) 10,0 SPECIICATIONS of pilot valves 2 3 4 5 6 7 8 9 10 11 12 isolation class pipe G maximum ambient C surface temperature 85 C 40 C 100 C 60 C orifice (mm) 135 C 75 C flow coefficient Kv (m 3 /h) (l/min) DC (=) Solenoids power level (watt) 22,0 isolation class operating pressure differential (bar) maximum (PS) min. air /= 1/8 3,6 0,35 5,8 0 8,5 1/8 3,6 0,35 5,8 0 8,5 (1) Intermittent duty, Relative Duty Time is 10%. Max on time is 1 min. (3) Heating element(s) 220240 VDC / VAC 5060 Hz standard, for other voltages see ordering information. Heating element(s) rating 80 watt each. maximum ambient C surface temperature 85 C 40 C 100 C 60 C 135 C 75 C without heating WPSDU G110A020 WPSDU G110A030 WPSDU G110A040 WPSDU G110A050 WPSDU G110A060 WPSDU G110A070 WPSDU G110A080 WPSDU G110A090 WPSDU G110A100 WPSDU G110A110 WPSDU G110A120 catalogue for ATEX approved boxes (2) 1 heating element (3) WPSDU G110A021 WPSDU G110A031 WPSDU G110A041 WPSDU G110A051 WPSDU G110A061 WPSDU G110A071 WPSDU G110A081 WPSDU G110A091 WPSDU G110A101 WPSDU G110A111 WPSDU G110A121 2 heating elements (3) WPSDU G110A072 WPSDU G110A082 WPSDU G110A092 WPSDU G110A102 WPSDU G110A112 WPSDU G110A122 (2) Minimum ambient temperature without heating elements: 0 C Minimum ambient temperature with 1 heating element : 40 C (2 to 6 pilots) : 15 C (7 to 12 pilots) Minimum ambient temperature with 2 heating elements : 40 C (7 to 12 pilots) X00331

PILOT VALVE BOXES SERIES WPSDU 110 OPTIONS Integrated quick fittings for 6 or 8 mm tubes Special customer adapted executions INSTALLATION The pilot boxes can be mounted in any position without affecting operation Pipe connections are: G 1/8 according to ISO 228 for pilot connection G 3/8 according to ISO 228 for common exhaust Cable entries: control cable on box with 2 6 pilot valves : cable Ø 7 12 mm control cable on box with 7 12 pilot valves : cable Ø 9 16 mm connection cable heating element : cable Ø 5 10 mm Installation/maintenance instructions are included with each pilot box Spare parts kit and replacement coils are available DIMENSIONS (mm), WEIGHT (kg) ORDERING INORMATION WP S DU G110 A 12 0 230/50 Volts/ Hz Optional execution 0 = no heating element 1 = 1 heating element 230V/50Hz 2 = 2 heating elements 230V/50Hz 3 = 1 heating element 24V DC 4 = 2 heating elements 24V DC 5 = 1 heating element 115V/50Hz 6 = 2 heating elements 115V/50Hz Number of pilots 02 = 2 pilot valves 03 = 3 pilot valves etc. (max. 12) Change letter of pilot valves A B C D 2 to 6 190 156 183 86 7 to 12 328 266 318 95 X00332 Basic G110 = threaded ports G120 = 6 mm quick fitting + TPL 22467 G130 = 8 mm quick fitting + TPL 22386 Approval according to Directive ATEX 94/9/EC Electrical connection spade terminals 6,3 x 0,8 Prefix (optional) WP: Waterproof IP 65 metal enclosure and cover X003GB2009/R8

PILOT VALVE BOXES containing 4 to 6 valves 2/2 normally closed, direct operated 1/4 NC OUT IN 2/2 Series C20 EATURES Compact pilot boxes with direct operated, integrated pilot valves Especially designed for the remote control of pulse valves (series 353) Pilot valves are assembled in base plate Heating element for trouble free operation at low ambient temperatures Class of protection: IP 65 The components satisfy all relevant EC directives General Differential pressure (PS) Response times fluid 0 7 bar [1 bar = 100kPa] 5 25 ms temperature range (TS) diaphragms air 20 to +80 C NBR (nitrile) CONSTRUCTION Baseplate Cover Core tube Core and plugnut Spring Disc Pilot body Shading coil Coil insulation class Electrical connection Steel (zinc plated) Castaluminium NBR (nitrile) Brass Copper Coil with screw terminal X003GB2009/R8 ELECTRICAL CHARACTERISTICS Standard voltages DC (=) 24V AC () 24V 115V 230V/50Hz nominal power ratings ambient coil inrush holding cold temperature protection type = range (2) (VA) (VA) (W) (W) ( C) SMXXB SMXXI (1) SPECIICATIONS of pilot valves 4 5 6 pipe Rp 56 orifice (mm) 35 16,7 flow coefficient kv (m 3 /h) (l/min) 30 15 to +85 15 to +85 moulded moulded operating pressure differential (bar) maximum (PS) min. air 1/4 5,6 0,71 11,8 0 7 (1) Intermittent duty, Relative Duty Time is 10%. Max on time 1 min. (2) Without heating elements: minimum ambient temperature 0 C: with one heating element: 15 C (3) Heating element: refer to "Ordering Information". Heating element rating: 80 watt. /= without heating C204220 C205220 C206220 catalogue for boxes (2) with 1 heating element (3) C204221 C205221 C206221 X00333

PILOT VALVE BOXES SERIES C20 OPTIONS Heating element for low ambient temperatures Special customer adapted executions on request INSTALLATION The pilot boxes can be mounted in any position without affecting operation Pipe connections are: Rp 1/4 according to ISO 7/1 for pilot connection Cable entries: control cable on box : cable Ø 13 18 mm connection cable heating element : cable Ø 6 12 mm Spare parts kit and replacement coils are available DIMENSIONS (mm), WEIGHT (kg) ORDERING INORMATION C20 6 2 2 0 230/50 100 94 Volts / Hz Optional execution 0 = no heating element 1 = element with same voltage as coils. If coil voltage deviates from heating element voltage, please consult us for exact codification Pipe Rp 1/4 Coil type only SMXX 3 105 34 Change letter Number of pilots 4 = 4 pilot valves 5 = 5 pilot valves 6 = 6 pilot valves Basic C20 83 94 1 Mounting : 2 holes Ø 10 with pitch D pipe connections C204 C205 Rp 1/4 C206 1 weight 3,7 4,1 4,6 Rp 1/4 X00334 336 47 266 X003GB2009/R8

PILOT VALVE BOXES for explosive atmospheres, zone 22 II 3 D IP65 T85 C to T200 C 4 to 6 valves NC OUT IN 2/2 Series C20 EATURES Pilot box intended for use in potentially explosive dusty atmospheres, according to Directive ATEX 94/9/EC Compliance with the Essential Health and Safety Requirements has been assured by European Standards EN 50014, EN 5028111 and EN 134631 Containing 4 to 6 valves, 2/2 normally closed, direct operated Pilot valves are assembled in base plate Heating element for trouble free operation at low ambient temperatures Class of protection: IP65 The components satisfy all relevant EC directives General Differential pressure (PS) Response times fluid 0 7 bar [1 bar = 100kPa] 5 25 ms temperature range (TS) seal material air 20 to +80 C NBR (nitrile) CONSTRUCTION Baseplate Cover Core tube Core and plugnut Spring Disc Pilot body Shading coil Coil insulation class Electrical connection Steel (zinc plated) Aluminium NBR (nitrile) Brass Copper Coil with screw terminal ELECTRICAL CHARACTERISTICS Standard voltages DC (=) 24V AC () 24V 115V 230V/50Hz coil inrush nominal power ratings holding cold ambient temperature protection type = range (2) (VA) (VA) (W) (W) ( C) SMXXB SMXXI (1) 56 35 16,7 30 15 to +75 15 to +75 moulded moulded X003GB2009/R8 TEMPERATURE CLASSIICATION TABLES AC () Solenoids power level (watt) 16,7 SPECIICATIONS of pilot valves 4 5 6 isolation class maximum ambient C surface temperature 85 C 40 C pipe Rp 100 C 60 C orifice (mm) 135 C 75 C flow coefficient kv (m 3 /h) (l/min) DC (=) Solenoids power level (watt) 30,0 isolation class maximum ambient C surface temperature 85 C 40 C 100 C operating pressure differential (bar) maximum (PS) min. air 1/4 5,6 0,71 11,8 0 7 60 C (1) Intermittent duty, Relative Duty Time is 10%. Max on time 1 min. (2) Without heating elements: minimum ambient temperature 0 C: with one heating element: 15 C (3) Heating element: refer to "Ordering Information". Heating element rating: 80 watt. /= 135 C 75 C catalogue for ATEX approved boxes (2) without heating DU C204220 DU C205220 DU C206220 with 1 heating element (3) DU C204221 DU C205221 DU C206221 X00335

PILOT VALVE BOXES SERIES DU C20 OPTIONS Heating element for low ambient temperatures 40 C Special customer adapted executions on request INSTALLATION The pilot boxes can be mounted in any position without affecting operation Pipe connections are: Rp 1/4 according to ISO 7/1 for pilot connection Cable entries: control cable on box : cable Ø 9 16 mm connection cable heating element : cable Ø 7 12 mm Spare parts kit and replacement coils are available DIMENSIONS (mm), WEIGHT (kg) ORDERING INORMATION DU C20 6 2 2 0 230/50 Volts / Hz Optional execution 0 = no heating element 1 = element with same voltage as coils. If coil voltage deviates from heating element voltage, please consult us for exact codification pipe connections C204 C205 Rp 1/4 C206 weight 3,7 4,1 4,6 328 10 Rp1/4 47 X00336 266 Pipe Rp 1/4 Coil type only SMXX Change letter Number of pilots 4 = 4 pilot valves 5 = 5 pilot valves 6 = 6 pilot valves Basic C20 Approval according to Directive ATEX 94/9/EC 75,5 6,5 10,5 X003GB2009/R8