Power Quality of Commercial Buildings

Similar documents
Power Quality Issues, Impacts, and Mitigation for Industrial Customers

Coordination of Telecommunications Surge Protective Devices in Countries with Unstable AC Power

Power Quality for Information Technology System

Power surges can also be generated by equipment in your facility such as:

Power Quality. Uninterruptible Power Supply

POWER QUALITY IN YOUR HOME

The Different Types of UPS Systems

Product Data Bulletin

Power Quality Standards for Electric Service

The Different Types of UPS Systems

Line Reactors and AC Drives

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

The Different Types of UPS Systems

D. Infrared scanning reports with pictures printed in a final report with any deficiencies and actions taken to rectify.

SIZING THE PRIMARY POWER SYSTEM FOR RESISTANCE WELDERS

Common Power Problems & Power Protection Solutions

Harmonics and Noise in Photovoltaic (PV) Inverter and the Mitigation Strategies

Typical Data Requirements Data Required for Power System Evaluation

Supply Standards: Electricity Supply Standard July JULY 2011 ISSUE 6 UNCLASSIFIED UNCONTROLLED COPY IF PRINTED

How the National Grid System Operates. Chris Gorman Lead Account Executive Syracuse

Power Quality. Voltage Sag Ride-through Mitigation in Sequence by Increasing Cost

Specifying a Variable Frequency Drive s

Uninterruptible Power Supplies (UPS) 1

Fundamentals of Power

Diesel Engine Driven Generators Page 1 of 6

Voltage Tolerance Boundary

21 st Century Facilities

Services. Three Phase Service

The Facts About Harmonics and Power Factor. Power Quality: Harmonics & Power Factor Correction

The Seven Types of Power Problems

ENGINEERING REPORT. XYZ Corporation 100 Anyplace Drive Chicago, Illinois 60613

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

ECE 586b Course Project Report. Auto-Reclosing

RVH/BCH Data Centres Proposals for Surge Protection and Ventilation

Specification guide no. 9 Active harmonic conditioner from 20 to 480 A

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

Video Camera Installation Guide

General Validation Test Program for Wind Power Plants Connected to the Hydro-Québec Transmission System

White Paper: Electrical Ground Rules

Engineering innovation

Technical Comparison of On-line vs. Line-interactive UPS designs

Power Quality For The Digital Age INVERTING SOLAR POWER A N E N V IRONME N TA L P OT E N T I A L S W HI T E PA PER

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

Current Transformers

PMCS. Integrated Energy Management Solution. Unlock the Full Potential of Power Networks Through Integration. Complete Solution. Informed Decisions

Power Quality & Custom Power

Working definitions of terms: Commercial vs. Industrial UPS Systems:

When power interruptions happen.

Cahier technique no. 196

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Fortune Oregon Data Center Increases Reliability with a High Resistance Grounding System

Theoretical review. Contents

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

Paralleling Power Sources Which Share a Common Neutral

POWER SYSTEM HARMONICS. A Reference Guide to Causes, Effects and Corrective Measures AN ALLEN-BRADLEY SERIES OF ISSUES AND ANSWERS

Guidance on Proper Use of EXTENSION CORDS, POWER STRIPS & SURGE PROTECTORS

Bypass transfer switch mechanisms

How To Understand The Electrical Power Supply Of A Power Supply System

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Mitigating data center harmonics

FACTS. Solutions to optimise network performance GRID

Emergency Power System Services Industrial UPS, Batteries, Chargers, Inverters and Static Switches

OPTIMIZING POWER SYSTEM PROTECTION FOR MODERN DATA CENTERS

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 1000VA, 2000VA & 3000VA Smart-UPS RC 230VAC Uninterruptible Power Supply

Session 10: General Overview of Interconnection Standards & Grid Codes for High Penetration PV October 21, 2015 Santiago, Chile

A COMPARISON OF TYPICAL UNINTERRUPTIBLE POWER SUPPLY (UPS) DESIGNS IN TODAY S MARKETS

Design of electrical power system for a 1000MW nuclear power generating station

Predictive Maintenance

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Troubleshooting accelerometer installations

CHAPTER 5 PHOTOVOLTAIC SYSTEM DESIGN

The reliability of the grid

Introduction. Harmonics and IEEE 519 Page 1 of 19

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Electrical Power System Fundamentals for Non-Electrical Engineers

Security+ Guide to Network Security Fundamentals, Fourth Edition. Chapter 13 Business Continuity

Eco-mode: Benefits and Risks of Energy-saving Modes of UPS Operation

System Grounding and Ground-Fault Protection Methods for UPS-Supplied Power Systems

Coaxial Cable Entry Panels, Coax and Grounding Connectors. Technical Note

Enhance Power Equipment Reliability with Predictive Maintenance Technologies

AC-Synchronous Generator

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Harmonic Distortion and Variable Frequency Drives

Considering the effects of UPS operation with leading power factor loads

Harmonics in your electrical system

Shunt Capacitor Bank Fundamentals and Protection

VOLTAGE REGULATOR AND PARALLEL OPERATION

SECTION STATIC UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Specification Requirements DBL 700MX and 1000MX Series UPS

TROUBLESHOOTING PRELIMINARY

A program for co-funded ASHRAE research relating to response to extreme events and anticipated harsh power system environments.

1+1 PROTECTION WITHOUT RELAYS USING IDT82V2044/48/48L & IDT82V2054/58/58L HITLESS PROTECTION SWITCHING

415V DISTRIBUTION FOR GREEN DATA CENTERS

POWERING LARGE SCALE HFC NETWORK

Power System Harmonics

Enhancement of load balancing for dynamic loads using D-STATCOM

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

LAP ENERGIA PARA DATACENTERS

Inverter / Charger Installation General Operations and AC and DC Connections

Transcription:

Hartford Steam Boiler One State Street P.O. Box 5024 Hartford, CT 06102-5024 Tel: (800) 472-1866 www.munichre.com/hsb June 2015 Background Power quality is a general term used to describe the quality of several different power-related characteristics. These characteristics are the frequency and amplitude of the voltage, the balance between phases on a three phase system and the distortion level of the waveform. Which of these characteristics are important and what is considered an acceptable level of power quality will vary from facility to facility. Most of the older electro-mechanical was robust and could handle minor power quality related issues with little or no effect on operations. But, due to the shift in the type of loads from electromechanical to electronic, power quality has become a real concern in all types of businesses. This includes hospitals, universities, commercial buildings and industrial facilities. Poor power quality results in a random misoperation of ; data corruption; loss of process control; and heating of cables, motors and transformers. Power Source An ideal power source offers a continuous, smooth sinusoidal voltage, as shown in Figure 1. Figure 1 Poor quality power as shown in Figure 2 contains noise, harmonic distortion, voltage sags and swells, interruptions and voltage surge. Figure 2

Page 2/5 s of Poor Power Quality The most obvious source of poor power quality would appear to be weather-related and utility-related disturbances. However, studies have shown that issues such as lightning, other natural phenomena, and utility operations, account for only a small portion of all electrical disturbances. A large portion of electrical disturbances are from internal sources or from neighboring businesses that share the same building or are in close proximity. Internal sources can be fax machines, copiers, air conditioners, elevators, and variable frequency drives just to name a few. Power Quality s Typical power quality issues include: voltage transients (surge), harmonics, voltage sag and swell, voltage imbalance and interruptions. Voltage Transient (Surge) Harmonic Distortion Voltage Sag / Swell Voltage Imbalance A sudden high energy disturbance in line voltage typically lasting less than one cycle (< one second) which causes the normal waveform to be discontinuous. Switching type loads. Data corruption, misoperation, damage and process interruption. Distortion of the current and voltage waveforms caused by the momentary on/off switching of nonlinear loads. Elevators, HVAC, rectifiers and welding machines. Data corruption, data loss, misoperation of computer controlled, excessive heat and failure. A decrease (sag) or increase (swell) in line voltage lasting at least 1/2 cycle (1/120 of a second) to several seconds. Utility related events, starting and stopping of large loads. If is operated slightly outside the design envelope, random misoperation and failure may occur. If the is operated significantly outside the design envelope, the will not operate and may fail prematurely. The effects are based on the length, magnitude and timing of the sag or swell. Differing voltage levels on each leg of a three phase system, typically < +/-2% of the average. Large loads in a building such as HVAC and elevators are three phase loads. The small but numerous loads such as copiers, control and computers are single phase loads. Single phase loads should be equally distributed among the three phases to prevent imbalance. Imbalance can also be caused by poor connections or blown fuses. Depending on the level of imbalance, loads can operate erratically, not operate at all or fail. courtesy of Advanced Protection Technologies Interruptions A significant or complete loss of voltage. The loss can be momentary or sustained. Weather, utility failures, internal faults or internal failures. A momentary interruption can damage computers and other electronically controlled or disrupt processes. The damage can occur on both the loss and the reenergization of power. Electro-mechanical is generally not affected by these brief outages. Sustained interruptions can last from hours to days. Contingency plans should be developed to address orderly and process shutdown and restarts.

Page 3/5 Solutions Each type of occupancy will have a different sensitivity level to poor power quality and will have different sources of poor power quality. However, common to all businesses is the importance of a wellmaintained electrical distribution and grounding system. The importance of these systems cannot be overstated. When addressing potential or actual power quality issues, the power and grounding system should be the first item addressed. This will ensure personnel safety, allow for the proper operation of surge protection devices, minimize the potential for currents on neutral conductors, and provide an adequate reference plane to electronic. Once the power and grounding system deficiencies have been addressed, the next steps include: power quality walk-throughs, power quality inspections / surveys, and mitigation. Walk-throughs are a means to understand a facility from a power quality standpoint. In addition to housekeeping and the overall appearance of electrical, items to note during a power quality walk-through include: Type of that is installed Concentration of computer and electronic Presence of welders, power factor correction capacitors, or variable frequency drives Heat discoloration of electrical Communication and control wiring in close proximity to power wiring Condition of the grounding system Presence of surge protection installed on power and data lines The conditions below are considered warning signs for potential power quality issues in a facility. These conditions do not guarantee a problem; however, a facility with these conditions will have an increased likelihood of power quality issues. History of power related issues Poorly maintained electrical system Failure of surge protection Weather and utility disturbances common High concentration of electronic Infrared surveys which identify current flow (heat) on grounding conductors and/or system neutrals Repeating and random misoperation, failures, tripping of breakers or blown fuses with no identified causes Equipment running hot Frequent switching to backup power systems Lost data or data corruption Based on the results of the power quality walk-through and the type of processes and at the insured s location, the following recommendations may be appropriate: Infrared thermography to locate troubled areas. Not all power quality related issues will cause hot spots but loose connections, harmonics and undervoltage will cause an increase in the operating temperature of. A power quality inspection and survey performed by a properly trained and experienced individual. The results of the inspection and survey should be reviewed by a trained and experienced engineer. A power quality study if an expansion is planned or a large load is being added. This study should be completed during the design of the expansion or during the specification process of the new piece of. Power quality inspections and surveys identify if there is a problem, the types of problems, the extent of the problems, and the potential solutions. Power quality inspections and surveys should only be completed by individuals with the required specific experience and training. In many commercial or light industrial type businesses, only a few loads are sources of power quality issues and only a few loads are susceptible to poor power quality. By identifying these loads during a survey, targeted and therefore less expensive mitigation techniques can be utilized. A power quality survey is the monitoring and recording of the power supplied to a building or in specific areas of a building. It is important to measure power continuously over an extended period of time such as days or weeks. This will permit all the intermittent events to be captured. Due to the difficulties in identifying power quality related issues, it is highly recommended that only electricians trained and experienced in power quality complete the surveys using the appropriate monitoring. The should be capable of recording very fast events (less than one cycle) and have data storage capabilities. Since it is physically impossible to monitor all points at the same time, selecting the best points to monitor is extremely important. This should be done based on the areas of concern identified during the

Page 4/5 inspection. The of concern must be energized and operating during the monitoring period. Do not perform a power quality survey during a shutdown. The review of the data from the survey will determine if a problem exists, identify the type and severity of the problem, and assist in recommending mitigation techniques. The review is performed by qualified and experienced engineers. Prior to selecting any type of mitigation, the power quality deficiencies responsible for operational issues and failures must be clearly identified. The next step is to estimate the costs of the power quality related issues. This aids in determining an expenditure target for the required mitigation. A wide variety of power quality correction products is available utilizing a range of technologies and providing a range of protection. Common mitigation techniques include surge protection devices, isolation transformers, voltage regulators, motor generators, standby power supplies, uninterruptible power supplies and harmonic filters. Each technique has advantages and disadvantages and should be applied based on the situation. This list is a good overall representation of the different types of mitigation techniques available but it is not a complete list of all the available techniques. Surge Protection Devices (SPD) Isolation Transformers Voltage Regulator Motor Generator Diverts surge events to ground. A device connected between line and ground which has high impedance at normal frequency (50 or 60 Hz) and very low impedance at the high frequencies associated with surge events. Because of this low impedance, the SPD acts as a shunt to ground for surge events. Devices vary in their surge current-handling capability and voltage-limiting capability. Since devices have different voltage and current capabilities, a multi level approach is required to protect against surge events. The multi level approach is also known as zones of protection. Each zone experiences a different level of surge event and therefore the SPD should be sized appropriately based on the zone. In general terms, the zones of protection are the service entrance, the load side of the main feeder, and the branch panels. If a device is connected to a modem or a data line, these lines represent a backdoor opportunity for surges to enter and destroy circuit boards. These lines must also be protected by surge protectors. Many types of claim to have built in surge protection. But these are often inexpensive varistors, which may or may not provide sufficient protection. They should not be relied upon to protect a piece of. Attenuates common-mode disturbances on the power supply conductors, provides a local ground reference point and with taps, allows compensation of steady-state voltage drop in feeders. A transformer with built-in surge protection and special windings with a grounded electrostatic shield between the primary and secondary windings. This grounded shield provides a path to ground which prevents high frequency noise from reaching the transformer output. Isolation transformers may step-down the voltage (i.e. 480v to 208v) or may provide just one-to-one isolation (208 V in and 208 V out). Provide a constant steady-state output voltage level for a range of input voltages. A variety of voltage regulation techniques is utilized. Common techniques include ferroresonant transformers, electronic tap-switching transformers, and saturable reactor regulators. Provides voltage regulation, noise/surge elimination, waveform correction for voltage distortion and electrical isolation between the electrical system and the loads. Two separate devices, a motor and an alternator (generator), interconnected by a shaft or other mechanical means. Typically the utility is the power supply for the motor which drives the generator to produce clean power.

Page 5/5 Standby Power Supply Inverter and battery backup power system operating as an outage protection system. In normal mode, the inverter is in a standby mode and the load is directly supplied from the input power source. On a loss of input power, the load is switched to the battery supply. There is a momentary break in power when the transfer to and from input power occurs. Usually comprised of a solid-state inverter, battery, and battery charger. Uninterruptible Power Supply (UPS) Maintain uninterrupted supply of regulated voltage for a period of time after a power failure. A variety of technologies exists. The two common types are rotary and static. A rotary unit consists of a motor generator set with a short ride through capability. A static unit utilizes power electronics and a battery string or other energy storage means as a source of energy during loss of input power. These units are only as good as their batteries. The battery system needs to be sized based on the load and duration of required time and needs to be well maintained. Other types include combinations of rotary and static units or UPS systems supplemented with engine driven generators for extended outages. The design of the backup power supply capability should reflect the criticality and size of the loads to be supplied. Redundancy should be in proportion to the level of risk. Each element of the backup power scheme needs to be viewed as a point of failure; if appropriate the design should provide for functional duplication of each. Harmonic Filters Acts to reduce the level of harmonic distortion on a power system. There are two types: series circuit and parallel circuit. Series inductor/capacitor (LC) circuits have a low impedance to harmonic currents and therefore act as a sink, preventing the harmonics from being fed back to line. Parallel inductor/ capacitor (LC) circuits have a high impedance to harmonic currents, and therefore block the flow of harmonic currents. NOT IF, BUT HOW 2011, 2015 The Hartford Steam Boiler Inspection and Insurance Company All rights reserved. ES004 Power Quality Advanced