FAAST. Fire Alarm Aspiration Sensing Technology



Similar documents
8251F FAAST Fire Alarm Aspiration Sensing Technology

HART HSSD High Sensitivity Smoke Detection

Advanced Fire Protection in Data Centres

Buys Time. Air Sampling Smoke Detection

SPECIAL APPLICATIONS

E-PDD Duct Smoke Detector Installation Sheet

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Aspirating Smoke Detectors 420 Series Special environments require very early detection

SSI. Modbus Analogue Output DEVICENET ETHERNETIP. Zero Slip, Zero Wear. Exact Measurement. No Moving Parts. Permanently Calibrated.

Flexible Aspirating Smoke Detection

PROTEC CIRRUS HYBRID ASPIRATING SMOKE DETECTION SYSTEMS

SMART SENSOR COLLECTION

Building Technologies

conventional system operation

Manual for Fire Suppression & Methane Detection System

CenterMind G+ Smart and Proactive Environment Monitoring

Passive Infrared Motion Detector 5420/90. Installation Instructions

How the People Counter Works. Enhanced Building Security and Improved Marketing Intelligence. 3D MLI Sensor Technology

Smoke Detectors Ordering Information DS230 DS230 Series Heat Detectors DS230F DS233F Peripheral Accessories EOL200 TP280 Bases Features

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

Introduction. Refrigerant Leak Detecting System. Feature and Benefits

Fire detection equipment

GE Security. FHSD Monitor / Web Server user manual

FIRERAY 2000 Installation Guide

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

DUCT SMOKE DETECTOR D4120

SECTION DETECTION AND ALARM

FIRE ALARM SYSTEM. reliable fire detection and alarm signalling system

Motion Detector 360 Degrees 5420/360. Installation Instructions REGISTERED DESIGN REGISTERED PATENT

Section 6 Fire Detection and Alarm Systems Russell Porteous Chief Executive Officer Firewize Services

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

TS93 EMR T/PT/TDE. Surface applied door closer

FIREDEX Conventional Fire Panels

Shunt lock function 3066

Industrial Control Solutions

Triple Waveband Infra-Red Flame Detection

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

Technical Overview CM-16 Climate Monitor. Get yours direct at:

Electronic Control Devices The European Product Catalogue 2007

The World's No. 1 Brand of Air-sampling Smoke Detector

Laser Technology Smoke Detector

Installation Manual. Rental Services. Air Handling Units CHS-SVN01A-EN. July 2008

T7560A,B,C Digital Wall Module

IS3016A Passive Infrared Motion Sensor with Anti-Mask - Installation Instructions

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

Tk20 Network Infrastructure

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 19

BERKELEY NUCLEONICS USER MANUAL BNC MODEL 960. This manual covers installation and operation procedures for BNC AM members:

ABLOY DOOR AUTOMATICS Easy access for all types of swing doors

IFC 070 Technical Datasheet

86 C Freezer Accessories. More Choices. Choose from a Wide Selection of Racks, Monitoring Systems and Other New Brunswick Freezer Accessories

HYDRUS ULTRASONIC METER

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

PD Monitor GIS. 24/7 Partial Discharge (PD) monitoring system for Gas Insulated Switchgear. Benefits NEW PRODUCT

2.0 Installation 1. Remove the cover using a small flat blade screwdriver. Figure 2: Cover Removal

QuickSpecs. Overview. HP Power Distribution Rack. HP Power Distribution Rack. DA North America Version 5 August 22, 2008 Page 1

HomeSafe-Basic VT-PS99E. User s Manual. PSTN Home Alarm System. Page: 1 / 15

Web-Based Remote Monitoring & Datalogging

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

AMI MARINE (UK) LTD BRIDGE NAVIGATIONAL WATCH ALARM SYSTEM (BNWAS) Operation Manual KW810

BroadBand PowerShield. User Manual

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

MONITOR ISM / AFx Multi-Tenant Security System User Guide V1.3

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

ALARMLINE ANALOGUE Linear Heat Detection System

WD-AMX Water Detection Controllers

INTREPID Perimeter Intrusion Detection System

Perimeter Security System

Fire Alarm system Installation Guide

SECTION FIRE ALARM AND SMOKE DETECTION SYSTEMS

Overview of Fire Alarm Systems and Maintenance

PSTN Home Alarm System

Technical Overview CM-2 Climate Monitor. Get yours direct at:

Aspirating Smoke Detection

Duct Humidity Transmitter

Data Centre Services. JT First Tower Lane Data Centre Facility Product Description

How To Control A Medical Device With A Pc System

MSL1000 Monitored Serial Link Interface Manual V1.01

Sensor Monitoring and Remote Technologies 9 Voyager St, Linbro Park, Johannesburg Tel: ;

CoolTeg Plus Chilled Water (CW) version: AC-TCW

Major Risks and Recommended Solutions

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

Aspirating Smoke Detection

/ Our accessories complement all PV systems, simplify installation and ensure that the system meets the required safety standards.

Y7230A CO 2 Alarm System

ENAiKOON ultrasonic fuel-level sensor

Best Practices for Wire-free Environmental Monitoring in the Data Center

Ademco Vista-20P/First Alert FA-168C Basic Commands

Model 201 Wiegand Touchpad Reader Installation Guide

QuickSpecs. HP Fixed Cord PDUs & Extension Bars (Zero-U/1U Modular PDUs) Overview

ACTIVE 5 ENGINEERING MANUAL

FAST, INTELLIGENT FIRE ALARM SYSTEMS THAT DELIVER IT ALL

TrueAlarm Fire Alarm Systems

Galaxy Flex SECURITY THAT FITS WITH YOUR BUSINESS AND LIFESTYLE. Protect your property

WIRELESS ALARM KIT INSTRUCTION MANUAL COMPLETE ALARM SYSTEM FOR HOME OR BUSINESS. Model Number: IT214054


Transcription:

FAAST Fire Alarm Aspiration Sensing Technology

The world s finest manufacturing facility System Sensor s European products are researched, designed and manufactured at our 10,000m2 state-ofthe-art facility in Trieste, Italy. Quite simply, it s the best of its kind. Advanced technology and manufacturing processes coupled with dedicated staff ensure precision manufacturing and incomparable quality control. And 100% testing ensures that nothing leaves our doors unless it s in perfect working order and capable of providing years of trouble-free protection. We complement this unique offering with a global network of fire systems integration and distribution partners who serve end-users, consulting engineers and specifiers in more than forty countries. All share in our business expertise and, of course, our passion for perfection.

Dual Vision. One Focus. When very early warning fire detection is essential FAAST is a ground breaking aspiration solution designed to deliver highly accurate and discrete early warning fire detection. Using unique dual vision technology and intuitive features that allow access to data from anywhere in the world, the product outperforms other aspiration systems on the market. FAAST not only delivers zero false alarms, zero downtime and 100% business confidence, integration into the main fire system reduces the overall cost of maintenance. FAAST Applications FAAST has one focus. To protect people, mission critical facilities and high value assets from the faintest traces of smoke, in a wide range of challenging environments. Mission Critical For these environments, there is no downtime. Every second lost, every transaction missed, any data or equipment destroyed can mean huge financial losses. FAAST alerts facility managers hours, even days before the first indication of system trouble helping them keep their mission critical facilities up and running 24/7 and preventing unnecessary activation of suppression systems. Discrete Detection When aesthetics matter, such as in museums, churches or mansions, FAAST provides a discrete smoke detection solution that is nearly invisible to the public. At the same time, it provides the earliest and most accurate smoke detection available to protect high-value items from fire. Restricted Access Some fire systems must protect areas such as prisons and public spaces, where there is a concern for tampering. The FAAST device can be mounted in a secure area while air sampling points are located in the protected environment minimising the potential for tampering. Public Protection In large public areas like shopping centres, airports, or stadiums, evacuations can be difficult. FAAST provides highly accurate fire detection for these areas to avoid nuisance alarms and various alert levels to enable an appropriate and informed response to any situation. Extreme Environments Some areas, like cold storage facilities or spaces with highairflow, have environmental conditions outside the tolerance of typical fire detection technologies. Because the FAAST device can be mounted at a temperate, easy-to-access location while sampling points can be located in the extreme environment, it enables reliable fire detection for areas with challenging conditions.

Features Detection as precise as 0.00046 %/ft obscuration Five alarm levels and two sensitivity modes provide application flexibility Dual flow detection including both ultrasonic and electronic sensing for pipe and chamber air flow measurement A single device protects up to 2,000 square metres Advanced detection algorithms reject common nuisance conditions Patented particle separator and field-replaceable filter remove contaminants from the system PipeIQ software provides intuitive system layout, configuration and monitoring all in one package Integral Ethernet interface enables remote monitoring and e-mail status updates Fault indictors provide a broad spectrum of events FAAST Delivers Dual Vision. One Focus. FAAST s dual vision sensing technology uses a blue LED to detect a wide variety of fires with extremely low concentrations of smoke and an infrared laser to identify nuisances (like dust) which can cause false alarms and downtime. Advanced algorithms interpret signals from both sources to meet one single focus to protect your facility, people and assets with the earliest and most accurate smoke detection available. Unique air flow pendulum graph verifies pipe network functionality Particulate graph displays subtle environmental changes for early problem indications Quick Set-Up FAAST s all-in-one system configuration and monitoring software, PipeIQ, guides you through initial pipe layout and system configuration. Once the system is installed, it enables ongoing configuration and system monitoring from anywhere in the world, via the Internet, using FAAST s onboard Ethernet connection. The PipeIQ software is included with FAAST. Intuitive Data FAAST provides you with the data you need to manage your environment. It includes 5 alarm levels, 10 pre-alarm particulate levels and a 10-level airflow pendulum which verifies that air is flowing effectively through the pipe network. It also includes a full range of fault indications. All of this information can be read quickly and easily on the device s intuitive integral display* or through a variety of remote devices. *Multiple language cards available. See Ordering Information. Stay Connected If there is a situation at your facility, you need to know about it instantly. FAAST s unique onboard Ethernet interface enables you to monitor the detector from any Internet browser, smart phone or mobile device with VPN capability. You can also configure the detector to deliver e-mail status updates to appropriate personnel. This means you will be advised of whatever you need to know to protect your facility no matter where you are.

The Aspirating Detection System The FAAST solution for Aspiration detection. Physical Specification Height 33.7 cm (13.25 inches) Width 33 cm (13.0 inches) Depth 12.7 cm (5.0 inches) Cable Access 2.54 cm cable entry holes on top and bottom of unit Wire Gauge 12 AWG (2.05 mm) max. to 24 AWG (0.5 mm) min. Maximum Single Pipe Length Maximum Branched (2) Pipe Length Maximum Air Inlet Holes 120m (390ft) 2 x 100m (328ft) of pipe or 4 x 90m (295ft) of pipe 36 holes Network Outside Pipe Diameter 25 mm (.98 inches) Internal Pipe Diameter 15-21 mm (0.591 to 0.827 inches) Sensitivity Range 0.00151 %/m. obs 13.1 %/m. obscuration Relays 8 form C, 3 AMP, programmable latching or non-latching Event Log 18,000 events stored Communication Network Ethernet monitoring, 6 E-mail address alerts Shipping Weight 3.8kg (8.5 lbs), includes packing material Electrical Specifications External Supply Voltage Remote Reset Time Power Reset Avg. Operating Current Alarm 18-30 VDC External monitor must be pulled low for a minimum of 100 ms 1 sec. 500 ma @ 24 VDC 650 ma All relays active, all alarm levels displayed. Voltage @ 24 VDC Maximum Current Draw 650 ma Voltage at 18 VDC Environmental Specifications Operating Temperature 0 C (32 F) to 38 C (100 F) Sampled Air Temperature Humidity Range IP Rating Coverage Area -20 C (-4 F ) to 60 C (140 F) 10 to 95% (non-condensing) IP30 Up to 2000sq. m (20,000 sq. ft.) Air Movement 0-1,219 m/min. (0-4,000 ft./min. )

European Head Office System Sensor Europe Javastrasse 2 8604 Hegnau Switzerland Tel: 0041 44 944 00 Email: sse.sales@systemsensor.com www.systemsensoreurope.com Copyright 2011 System Sensor. All rights reserved. All technical data is correct at time of publication and is subject to change without notice. All trademarks acknowledged. Installation information: in order to ensure full functionality, refer to the installation instructions as supplied. LTR1201-1