FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Similar documents
Recommended Product Specifications Fuel Day Tank System Tramont UTRS Fuel Day Tank

Reliant Series Fuel Tanks. Day Tanks Filtration Tanks Specialty Tanks

Morrison Bros. Co. General Product Specifications

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

Fire Pump Plan Review March 2010

Oil and Coolant Circulating Heating System. Model - OCSM

Midwest Industrial Tanks

Industrial Generator Set Accessories

NFPA31FuelOilPiping 1 Revised


Spill Containers. 517 Series 3 ½ Gallons AST Spill Container. 518 Series 7 ½ Gallon AST Spill Container. 515 Series AST Remote Spill Container

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Diesel Engine Driven Generators Page 1 of 6

BERMAD Fire Protection

STEAM AND CONDENSATE PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD PART 1: GENERAL Purpose:

REGULATORS 175/153 Series

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

with MERCURY FREE 1 HP Relays ! WARNING Before using this product read and understand instructions.

FUEL SYSTEMS OUR PARTS PUT YOU IN THE PASSING LANE. Protect your fuel system. velvac.com

Model: 400E-2M. Bermad Electrically Controlled Deluge Valve with Easy Lock Manual Reset. Installation Operation Maintenance. Application Engineering

BERMAD Fire Protection

MAC-120HE-01 Air-Cooled Chiller

Commercial Semi-Instantaneous Water Heaters

300 Series PA Pump and Cooler Assemblies

Horizontal Split Case Fire Pumpset Diesel Engine Driven

Application for the Construction or Installation of Aboveground Storage Tank (AST) Systems or Associated Underground or Over-water Piping Systems

OREGON FIRE CODE Interpretations and Technical Advisories

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

TECHNICAL BROCHURE BAQUABII. * Available up to 100 GPM systems. Aquavar ABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

UST RULES CHANGES. Heather Peters, Environmental Specialist

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

Northern Region. Underground Storage Tank

HENRY TECHNOLOGIES - OIL LEVEL REGULATORS (CONVENTIONAL)

Medical Air Systems: Scroll

Explosion-Proof Electric Unit Heaters

HELIPORT FUEL/WATER SEPARATOR MODEL H-200

Model 1210C Battery Powered Pump Shown. Description

Section 8 Storage Tanks & Equipment

2010 Residential Water Heater Replacement Check List

An Engineering Guide to Modern Fuel Systems

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Horizontal Jet Pumps 1/3-1-1/2 HP

Chapter 5. Components, Symbols, and Circuitry of Air-Conditioning Wiring Diagrams

GE Oil & Gas. Texsteam * Pumps: precise chemical injection pumping

ELECTRIC/DIESEL FIRE PUMP CHECK LIST

DIESEL & JET FUEL FILTRATION EQUIPMENT. Applications:

Magnum Mobile Generator MMG55 Specifications

Element D Services Plumbing

LOADING DOCK EQUIPMENT. A. Section Concrete Forms and Accessories: Placement of anchors into concrete.

Trash Pumps Models: 56200, , 56201, , 56300, , 56301,

OPL BASIC. Dosing System for Professional Laundry machines. Contents

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

FUEL-OIL PIPING AND STORAGE

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

Technical Requirements for Aboveground Storage Tanks (ASTs) Storing Class IIIB Liquids (other than used oil)

Heavy-Duty Lube and Fuel Truck Sales Tool

SECTION VARIABLE FREQUENCY DRIVES

AIR RELEASE, CLEANOUT, AND SEWER MANHOLES

BERMAD Waterworks. Quick Active Check Valve. 700 Series. Model 740Q. Features and Benefits. Major Additional Features

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

FAIRBANKS NIJHUIS FIRE PUMPS.

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

Low Profile Unit Cooler

Pump Specifications 405 Series Commercial Drain Pump (High-Temp) 2 Solids handling

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

TMS TANK MANAGEMENT SYSTEM

FLASH TANK ECONOMIZER PRODUCT GUIDE

SECTION 13XXX DISPERSAL PUMP STATION (4x4 DiPS)

Air Eliminators and Combination Air Eliminators Strainers

Centro-Matic Automatic Lubrication Systems System Controls

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

ETZGAR CONVEYOR COMPANY Controls Section v12.05

HVAC Preventative Maintenance Basics. Presented by Mike Crawley

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

JOB or CUSTOMER: ENGINEER: CONTRACTOR: SUBMITTED BY: SPECIFICATION REF: QUANTITY TAG NO. MODEL NO. GPM FEET LEAD LENGTH COMMENTS.

Dual wall sub-base fuel tanks-ibc Certified kw DGHCA/CB/CC/DA/DB (4BT3.3G5) DSFAA/B/C/D/E (QSB5G3) DSGAA/B/C/D/E (QSB7G5) DSHAA/B/C/D (QSL9G2)

SPACE COOLERS. P.O. Box 956 Paoli, PA (800) FAX (610) The leader in packaged Space Cooling.

SUMP PUMP. Sump Pump Backup Systems. City of Ann Arbor B A C K U P O P T I O N S. Does everyone need a backup system?

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

Heating, Ventilation, Air Conditioning and Refrigeration (HVACR)

Model 763 AURORA. 750/760 Series APCO-PM CONSTANT PRESSURE BOOSTER SYSTEMS

VLT Series 300 Watt True Sine Wave Inverter

VOYAGER 570G. 744A Sprayer Control

Electric Motor Operator for: Gate Valves / Butterfly Valves / Plug Valves M&H VALVE

*.ppt 11/2/ :48 PM 1

SENTRA SERIES WATER UNITS. 30 to 300 F Process Temperatures. 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 10 to 34 KW Stainless Steel Heaters

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

AIR LINE VALVES AND GAUGES

understanding medium frequency induction melting furnace and its components

Electronic Flow Switches

CONTROL PANEL INSTALLATION INSTRUCTIONS. Single Phase Simplex Page Phase Simplex Page 8-13

TorqPlus TM Electric Valve Actuators and Controls

What Does A Sump Pump Do?

Horizontal Split Case Fire Pumpset Electric Motor Driven 50 Hz

The following definitions apply with regard to requirements specified in this document:

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

ENGINE COOLING SYSTEM

Transcription:

FUEL OIL DAY TANKS SST Series - Engineering Submittal SST Series - Advanced Line Day Tanks Construction: UL 142 aboveground steel tank all seam welded, square, atmospheric tank of heavy gauge steel with internal reinforcements, tested to 5 PSI test pressure. Welded flange pipe fittings for fuel return, overflow, vent, drain. Submerged fuel oil supply drop tube. Heavy gauge steel channel feet with mounting holes. Separate mechanical and electrical compartments, each with steel housing and removable access covers. Standard equipment: MODELS SST 10 10 gal. SST 25 25 gal. SST 50 50 gal. SST 75 75 gal. SST 100 100 gal. SST 150 150 gal. SST 200 200 gal. SST 275 275 gal. SST 325 325 gal. SST 400 400 gal. 2 GPM SUPER-XL Pump SST Controller Secondary Containment Option 190: Option 191: UL142 Secondary Containment Dike Leak Sensor SST Level Controller: UL 508 LISTED Super-XL Pump: The SUPER-XL Pump consists of the following: 2 GPM, high vacuum, positive displacement gear pump consisting of two pressure loaded, intermeshing, hardened steel, precision ground gear assemblies within a high strength die cast aluminum housing. Mechanical shaft seal. Pressure loaded to be self-compensating for internal wear. 1/3 HP, 120V, single-phase ODP motor. Oversized for high starting torque. Motor overload protection Optional pumps-motors available. Indication Functions Indicators are long life, extra-bright large display, L.E.D. s: Fuel level Power available Switch off (flashing) Pump running Low level alarm Overflow alarm/pump control backup activated Outputs Pump start-stop (1HP) Low level alarm (60W) High level alarm (60W) Control Functions 120V AC or 24V DC Auto-off-manual pump control switch Press to test pump push-button Pump start-stop automatic level control Automatic disconnect of pump on overflow/high level alarm

FUEL OIL DAY TANKS - SST Series Engineering Submittal page 2 Fuel Supply Network This is an industrial product, not a consumer product. It must be specified, installed, operated and maintained by individuals equipped with the appropriate training and skills. This tank conforms to applicable portions of the following standards: NFPA 30 and NFPA 37, UL 142, UL 508. All fuel piping should be of black iron or copper pipe. Pipe sizes should follow engine manufacturer s recommendations based on KW of generator set. WARNING A Dangerous Installation Will Result If Properly Sized Overflow And Vent Pipes Are Not Connected To This Tank. Overflow Pipe Should the tank be overfilled as a result of misadjustment of fuel level controls, fuel spillage or overpressurization of the tank may result. An overflow pipe back to the main storage tank of at least double the size of the fill pipe must be installed with consideration given to length of run and vertical drop. (Use min. 1" I.D.) Vent Pipe A properly sized and installed vent pipe is mandatory. The vent provides a means for tank to breathe when fuel is withdrawn or added to tank. Venting also provides pressure relief in case of overfill or rapid expansion or gasification of contents in event of fire. Portions of this tank may become permanently distorted at pressures above 5 PSI, and may rupture at pressures above the designed maximum withstand pressure of 25 PSI. To avoid overpressurization a vent pipe to atmosphere (outside of the building) of the same diameter as the threaded vent fitting installed in the tank must be provided to extend a minimum of 5 ft. above tank top, however, no portion of this vent should extend or terminate more than 12 ft. above this tank. There must be no low portions or sags in the vent pipe which can trap liquid. Protect the open end by suitable means to prevent entry by insects, foreign matter and precipitation. NOTE: The emergency vent line capacity specified on the placard at the top of the tank must be considered in order to maintain the fire safety factors established by NFPA 30 and UL 142. If installation is intended to conform and benefit from the inherent safety advantages of the NFPA 30 and UL 142 installation standards, observance of the value is mandatory. It may be necessary to increase the vent pipe diameter if the run is long, or install an emergency vent at the tank. Maintenance Every Six Months: Inspect this tank at least every six months for damage, leakage, or rust on both inside and outside of the tank. Promptly repair or replace any significantly damaged or deteriorated tank. Annually: Drain water and sediment from day tank sump at least once each year, or more frequently depending on usage and condition of the fuel. Recommended Options Main Storage Tank Is Underground: When the main fuel storage tank is located underground, one of the following options is recommended to assure maintenance of day tank pump prime. Option 070: Check valve on pump intake, Option 080, 083: Solenoid valve on pump intake, Option 090: Foot valve. Initial Installation: Hand pump is recommended for use as a backup to the motor pump and to prime the motor pump on initial installation. Option 015: 5 GPM (5 strokes/gallon) hand pump. Special Requirements Above Ground Storage Tank: When the main fuel storage tank is located above the level of the day tank, the following options are required; Options 060, 080, 087: Solenoid valve, with fuel strainer, on intake to prevent tank flooding. Consider also: #190/191: Overflow basin and overflow alarm, #383: Overflow-return tank, #390: Overflow return pump and controller.

FUEL OIL DAY TANKS - SST Series Engineering Submittal page 3 Piping & Installation Note: All fuel piping should be of black iron or copper pipe. Pipe sizes should follow engine manufacturer s recommendations based on KW of generator set. Emergency Vent: For tanks equipped with emergency tank vent (100-400 gallon), install weighted type emergency vent cap (Option #064) at this fitting. Install vent on 18-inch riser.

FUEL OIL DAY TANKS - SST Series Engineering Submittal page 4 Tank Dimensions 10-25 Gallon Tanks Size W" D" H" Wgt. 10 24.00 16.00 39.81 126 lbs. 10* 29.25 26.00 41.42 188 lbs. 25 24.00 16.00 52.56 169 lbs. 25* 29.25 26.00 54.17 277 lbs. 50 24.00 22.75 57.06 210 lbs. 50* 31.25 32.50 58.67 398 lbs. 75 24.00 22.75 72.31 212 lbs. 75* 31.25 32.50 73.81 360 lbs. 100 24.00 28.50 72.31 232 lbs. 100* 31.25 38.38 73.81 478 lbs. 150 32.13 28.00 76.56 550 lbs. 150* 42.00 35.00 78.06 826 lbs. 200 32.13 37.50 76.56 610 lbs. 200* 42.00 44.50 78.05 810 lbs. 275 32.13 52.00 76.56 700 lbs. 275* 42.00 59.00 78.05 820 lbs. 325 32.13 60.50 76.56 900 lbs. 325* 42.00 67.75 78.05 1090 lbs. 400 32.13 74.00 76.56 1000 lbs. 400* 42.00 81.25 78.05 1200 lbs. *with rupture basin with rupture basin 50-400 Gallon Tanks with rupture basin

FUEL OIL DAY TANKS - SST Series Engineering Submittal page 5 10-25 Gal. 50-400 Gal. Port Description Size " Size " A Engine Supply Drop Tube 0.50 0.75 B Siphon Drain Drop Tube 0.50 0.75 C Overflow Port 1.00 1.00 D Engine Return Port 1.00 1.00 E Extra Pipe Flange 1.00 1.00 F Tank Vent Port 1.50 2.00 G Manual Fill Port 2.00 2.00 H Hand Pump Mounting Port 0.75 0.75 J Pump Connection To Tank Drop Tube 0.50 0.50 K Floatswitch Mtg./Inspection Port 3.50 3.50 L Pump Motor Mounting Bracket M Emergency Tank Vent (100-400 gal.) 4.00 Tank Fittings 10-25 GALLON TANK FITTINGS - TOP VIEW 100-400 GALLON TANK FITTINGS - TOP VIEW 50-75 GALLON TANK FITTINGS - TOP VIEW Finish Rust-inhibitor coated interior. Exterior of tank chemically treated to resist corrosion, primed and finish painted light gray. Top cover painted blue.

FUEL OIL DAY TANKS - SST Series Engineering Submittal page 6 Control Panel Wiring Legend/Parts List ITEM PART NO. DESCRIPTION FS1-FS4... 25242150... Float Switch vertical float activation SPST, 20 VA pilot duty switch logic by reversing float MOT... 24626100... Motor Standard 1/3 Hp, 115V, 1ø, 60 Hz, 6.6 Fla, thermally protected, auto reset MOT... 24630000... Optional Motor Option 700 1/2 Hp, 115V, 1ø, 60 Hz, 9.2 Fla, thermally protected, auto reset TB PS... 25663400... Terminal Block 20A, 30V, 12 line SST Day Tank... 50001000... Liquid Level Controller P.C.B.1 printed circuit board, 24VDC input supply voltage, 4 liquid level inputs Standard... 50016500... Power Supply Power Supply printed circuit board P.C.B.2 120 VAC input, 2 A fused, 24 DC output (full wave rectified), 56 VA Serviceable SST PCB Component Parts SIMPLEX ITEM PART NO. DESCRIPTION Indicators... 24249650... Green LED, Socket Mount 24249700 Amber LED, Socket Mount 24249600 Red LED, Socket Mount PCRX... 24832000... Motor Starting Contactor 24 VDC Coil, 1 pole, normally open Contacts rated at 1 Hp @ 125 VAC 2 Hp @ 250 VAC 30 Amp, 277 VAC (resistive) F1-F3... 14010000... Fuse 2A, 250 VAC, AGC-2

FUEL OIL DAY TANKS - SST Series Engineering Submittal page 7 Mechanical 010 Auxiliary hand pump 015 Auxiliary hand pump 025 Locking manual fuel fill cap 040 Wall-mounting brackets 050 Pipe stand adapter 060 Fuel strainer 062 Duplex strainer 063 Vent cap 064 Emergency vent 065 Drain hand valve 068 Emergency quick-drain 070 Priming tee & check valve assembly 080 AC Solenoid valve 083 DC Solenoid valve 087 Manual shut-off valve, bronze 088 Manual shut-off valve, fire rated 090 Foot valve 093 Fusible link valve 095 Pressure relief valve 100 Pressure gauge 101 Vacuum gauge 103 Flow gauge 104 Ball motion flow indicator 120 Extra 1 NPT pipe connection 125 Extra supply suction tube 130 Oversize pipe connection, 1 ¼" to 2 ½" NPT 131 Oversize pipe connection, 3 to 6 NPT 140 Special paint color 141 Epoxy primer 150 Extra-heavy tank construction 180 Weatherproof Modification 185 2 or 3 complete day tanks mounted on common base 190 Overflow basin 191 Rupture float switch 192 Basin drain hand valve 194 Gravity drain for overflow basin, use with option 190 195 Screen top for overflow basin 196 Weatherproof cover for overflow basin Control Devices and Alarms 260 Disconnect switch 261 System circuit breaker 262 Control power transformer 265 Day tank heater 270 Power available green pilot light 280 Operation mode selector switch 285 Loss of flow alarm 295 Remote low fuel level alarm dry signal contacts 080 Solenoid valve 376 Manual reset solenoid valve 180 Weatherproof Modification 190 Overflow basin 196 Weatherproof cover 297 Remote high fuel level alarm dry signal contacts 299 Auxiliary relay, use w/options 295 & 297 above 311 Local/remote low fuel level alarm, sensing 30% of capacity 312 Local/remote high fuel level alarm, sensing 103% of capacity 325 High fuel level emergency pump-stop switch 326 High level cutout for SDE Series only 329 Low fuel level red light 333 Critical low fuel level alarm-engine shut down 334 Alarm horn 340 Pump Running amber light Options Checklist

FUEL OIL DAY TANKS - SST Series Engineering Submittal page 8 Options Checklist cont d Duplex Pump Systems 345 Multifunction duplex pump controller 346 Two running time meters 347 Manual duplex pump selector switch Gravity Fed Day Tanks 060, Solenoid valve, 080, with fuel strainer, on 087 intake to prevent tank flooding 376 Manual reset, normally open, electrically operated valve 377 Siphon-break solenoid valve for remote installation 378 Anti-siphon valve 383 Overflow-return tank 390 Overflow return pump & controller 150 Extra-heavy tank construction 190, Overflow basin and 191 Overflow alarm Sight Glasses 211 Safety sight glass without rupture basins 212 Electric level gauge on tanks, 12" min. tank depth 214 Digital fuel flow indicator Fuel Oil Coolers 396 Radiator with electric fan, flow switch Pumps and Motors 002 Deletion of Standard Pump & Motor. 10A @ 125/250V AC, 10A @ 30V DC, Form C contacts provided 400 7 GPM pump 410 10 GPM pump 415 17 GPM pump 417 25 GPM pump 420 3 GPM pump 422 5 GPM pump 424 11 GPM pump 426 13 GPM pump 428 36 GPM pump 430 45 GPM pump 432 61 GPM pump 510 Transformer, 480/120V AC, 1ø, 50-60 Hz 511 Transformer, 480/120V AC, 1ø, 50-60 Hz 605 1 /3 HP, 230V AC, 1ø, 60 Hz motor, ODP 615 1 /3 HP, 110V AC, 1ø, 50 Hz motor, ODP 616 1 /3 HP, 220V AC, 1ø, 50 Hz motor, ODP 621 1 /3 HP, 230/460V AC, 3ø motor, ODP, w/starter 622 1 /3 HP, 230/460V AC, 3ø motor, TEFC, w/starter 630 1 /3 HP, 12V DC motor 635 1 /3 HP, 24V DC motor 645 1 /3 HP, 115V AC, 1ø, 60 Hz, motor, TEFC 700 ½ HP, 115V AC, 1ø, 60 Hz motor, ODP 705 ½ HP, 230V AC, 1ø, 60 Hz motor, ODP 715 ½ HP, 110V AC, 1ø, 50 Hz motor, ODP 716 ½ HP, 220V AC, 1ø, 50 Hz motor, ODP 721 ½ HP, 230/460V AC, 3ø motor, ODP 722 ½ HP, 230/460V AC, 3ø motor, TEFC, w/starter 730 ½ HP, 12V DC motor 735 ½ HP, 24V DC motor 745 ½ HP, 230/115V AC, 1ø, 60 Hz motor, TEFC 768 Single phase magnetic motor starter 770 3-phase magnetic motor starter 800 ¾ HP, 115V AC, 1ø, 60 Hz motor, ODP 805 ¾ HP, 230V AC, 1ø, 60 Hz motor, ODP 825 ¾ HP, 230/460V AC, 3ø, 60 Hz 900 1 HP, 115V AC, 1ø, 60 Hz motor, ODP 905 1 HP, 230V AC, 1ø, 60 Hz motor, ODP 925 1 HP, 230/460V AC, 3ø, 60 Hz motor, ODP, w/starter Optional motors requiring SPS/SKS Pump Set when used with 10 through 400 gallon models 1000 1½ HP, 115V AC, 1ø, 60 Hz motor, ODP 1005 1½ HP, 230V AC, 1ø, 60 Hz motor, ODP 1025 1½ HP, 230/460V AC, 3ø, 60 Hz 1100 2 HP, 115V AC, 1ø, 60 Hz motor, ODP 1105 2 HP, 230V AC, 1ø, 60 Hz motor, ODP 1125 2 HP, 230/460V AC, 3ø, 60 Hz 1200 3 HP, 115V AC, 1ø, 60 Hz motor, ODP 1205 3 HP, 230V AC, 1ø, 60 Hz motor, ODP 1225 3 HP, 230/460V AC, 3ø, 60 Hz 1305 5 HP, 230V AC, 1ø, 60 Hz motor, ODP 1322 5 HP, 230V AC, 3ø, 60 Hz motor, TEFC 1325 5 HP, 230/460V AC, 3ø, 60 Hz 1405 7½ HP, 230V AC, 1ø, 60 Hz motor, ODP 1422 7½ HP, 208V AC, 3ø, 60 Hz motor, ODP 1425 7½ HP, 230/460V AC, 3ø, 60 Hz