Demand-controlled ventilation with Air Comfort Control

Similar documents
MODEL: DV72. Mechanical Ventilation with Heat Recovery Installation Instructions and User Manual. Configuration Left Hand Right Hand

Supplying. your home with. Our wall-mounted ventilator range: flexible, powerful ventilation technology for a healthy environment.

Duplexvent DV72 EC So light, so slim it fits inside a 600mm cupboard

Indoor Air Quality FILL YOUR HOME WITH AIR THAT IS AS CLEAN AS IT IS COMFORTABLE. READ ONLY

HERZ-Thermal Actuators

Mistrale. Fusion Terminal

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

RRV934. Multi-controller. Synco living

EFA PSBP. Natural Ventilation Strategy. Introduction. 1.1 Relevant legislation The Building Regulations 2010

Flexit air handling unit K2 R

Solar Homes Catch the Sun. Are you planning a new house? Discover how you can apply solar architecture principles to:

RPV - RP - RA air handling units

Zehnder Focus 200. Ventilation device

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

air conditioners how to choose a cooling system

Delivering exceptional performance and Ecovalue. Ecocent

Energy Efficiency HOSPITALITY.

06150 PORVOO, FINLAND Pelican eco ED(D), Pelican eco EDE(D), Pelican eco EDW(D), Pelican eco EDX(D)

How To Get A Passive House

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

HRU ECO 4. System 4 Continuous Mechanical Supply and Extract Ventilation with Heat Recovery Appendix Q Eligible

ECOCIAT. Domestic hot water heat recovery unit

BACKGROUND VENTILATION SOLUTIONS FOR DOMESTIC BUILDINGS

york air-conditioning products Residential & VRF News 2015

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Under sill units. Type FSL-B-ZAS

WHOLE-HOUSE VENTILATION SYSTEMS

KNX TH65-AP. Thermo-Hygrometer. Technical specifications and installation instructions Item number 70184

All the best brands all under one roof

Horizontal ventilation units

Drayton Digistat +2RF/+3RF

Installation, operation and maintenance manual TX 35A

Combi Unit Genius. The energy efficient Building Service Centre

Ductless Systemss A COMFORTABLE, CONVENIENT SOLUTION BUILT TO A HIGHER STANDARD. READ ONLY

Rittal TopTherm fan-and-filter unit

Brochure EX

Industrial infrared heater IR For premises with large volumes and high ceilings

How To Make Your House Breathe

Residential HVAC Load Sizing Training October 14, David Kaiser Green Code Plan Reviewer

KONRAD. Hybrid Fancoil Series

Accessory Manual Ventilation Section Model Comfort Circle

ECO-VENTILATION Single-room energy recovery ventilators

Energy Efficiency. Bars & RestauRants.

1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

Défumair XR. ventilation and cmv. fire grade - label CE. smoke-extraction fan extraction casing for kitchen at F advantages.

UDSA - UDSBD unit heater

News! Flexit S20 R. Air Handling Unit. A new generation of Air Handling Units. For a healthy indoor envionment

FULL DC INVERTER SYSTEMS

Flexit SPIRIT K2R. Air handling unit with integrated kitchen hood

Energy savings in the residential area are essential in

TYXIA. * _Rev.1* Installation and User Guide. Wireless receiver. TYXIA RF channel

Heating and cooling. Insulation. Quick facts on insulation:

Energy Efficient Air Distribution Systems

New Deluxe Wall Mounted Heat Pump Series EXTERIOS

Operation and Installation Manual. Max Series

IH E Sigma Island 90

FLEXIT S4 R S6 R S7 R

Mechanical and Natural Ventilation

FTXS. Wall Mount Heat Pump or Cooling Only

Unico Inverter. Unique and efficient.

SERVICE MANUAL. Domestic Air Conditioner. Model. Feature HW-05LN03

CONTENTS 1. IMPORTANT NOTICE 2 2. TECHNICAL SPECIFICATION 3 3. OPERATION DETAILS 4 4. WIRING DIAGRAM EXPLOSION VIEW 12 6.

Filterfans. Air Flow data: PF 1000 PF 2000 PF 2500 PF 3000 PF 5000 PF 6000 PF 7000

We have been working in an ideal climate for thirty years.

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

KNX for building and room automation simple and efficient

CEN/TC 156. pren Date: CEN/TC 156. Secretariat: BSI ICS: Descriptors:

Heating / Ventilation / Air Conditioning Room Climate Control with ABB i-bus KNX

Material test chamber with mechanical convection

Ventilation Solutions Fresh Air Solutions for Ductless Heating & Cooling. fantech

CADB and CADT-D / DI / DC Series

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

Model: AC-S13CG x 2. Model No: AC-S13CGx2.doc Version 1.0

Digital inductive conductivity transmitter

The Finnish Classification of Indoor Environment and Material Emissions

HDA

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Air Movement. Heaters Desk Fans Wall Fans Pedestal Fans Ceiling Fans Extractor Fans Hand Dryers Air Conditioners. Pg

MULTISPLIT SYSTEMS AIR CONDITIONING SYSTEMS

Comfosystems Systems with heat recovery for a comfortable indoor climate

saving energy in comfort Factsheet Recair Enthalpy

2014 Performance RAK-PPA/PPB. 19th December 2013 RAC Product Planning Division

PCRNZ0710H. the. ultimate. heat pump air conditioning guide

Installation and maintenance instructions. Danfoss Vent

Important Safeguards

IEQ-15 Air Distribution System

Portable Air Conditioner

Dehumidifier D 850E. - Instruction manual version 02

TD-SILENT Series (160 to 1000 models) TD-SILENT Series (1300 and 2000 models) NEW TD-SILENT. In-Line duct fans

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

Heat Recovery based on Exhaust Air

your comfort. our world. User Guide Altherma HT For your new Daikin Altherma high temperature heat pump

2006 APC corporation. Cooling Solutions and Selling Strategies for Wiring Closets and Small IT Rooms

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

8W! SILENT-100 Series. 26,5 db BATHROOM EXTRACT FANS. Bathroom and toilet extract fans SILENT-100. Low noise! Water protected! Energy efficient!

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

USER S MANUAL HSC-24A

forair optimal air environments ResidentialPresentation

Solar Heating Basics Page 1. a lot on the shape, colour, and texture of the surrounding

Transcription:

Demand-controlled ventilation with Air Comfort Control

Efficien new and EPC gains up to 0.24! THE SYSTEM ADVANTAGES Demand-controlled ventilation Effective decentralised mechanical air supply Very high sound attenuation Air filtration Central mechanical air extraction Manual, programme or CO 2 sensor control Very easy installation Plug and play Air Comfort Control (ACC) by Brink Climate Systems is a whole-house ventilation system that automatically controls the ventilation on-demand. With its simple installation, ACC offers a unique ventilation concept to create a healthy and comfortable indoor climate in new as well as existing buildings efficiently. 2

t ventilation of existing buildings air in the winter and cooling warm ventilation air during the hot summer nights. EPC gains up to 0.24 are possible. AIR COMFORT CONTROL With Air Comfort Control (ACC), Brink Climate Systems offers a simple, effective and efficient method for ventilating both new and existing buildings. The ACC system combines air supply, air extraction and demand control. Every habitable room receives fresh outdoor air through our air supply units Sonair (wall-mounted) or Innoventus (mounted behind a radiator). A central mechanical extraction unit extracts stale indoor air from the wet rooms. DEMAND-CONTROLLED VENTILATION The control panel, which communicates with the above units through the electrical ring mains, controls the ventilation in each room individually and based on occupancy, either by manual, programme or CO 2 -sensor control. The system can be set to ventilate at a minimum rate to remove other pollutants, such as VOC s, formaldehyde and radon. That result is a healthy, comfortable, and low-energy indoor climate. Please read the ACC checklist for more information about the system. ENERGY SAVINGS The ACC system ensures that the rooms are only ventilated when necessary. This prevents excessive and uncontrolled ventilation (as well as draught) and limits thermal loss due to heating cold ventilation THERMAL COMFORT Independent studies have shown that the controlled supply of fresh outdoor air by Sonair and Innoventus is extremely comfortable, even when the outdoor air temperature is very low. This guarantees a comfortable indoor climate without draught, even when it is cold outside NOISE INSULATION The ACC system is an excellent choice for dwellings and schools where attenuation of outdoor sound is necessary. Sonair can attenuate up to 56 db of outdoor noise. SIMPLE INSTALLATION The individual components of the ACC system are very easy to install. They communicatie with each other over the electrical ring mains. This makes installation of separate control cabling superfluous. As a result, ACC can easily be applied to both new and exisiting dwellings. 3

A healthy indoor cl Independent studies show that the physical properties of the air supply units result in a very high thermal comfort. Air supply unit Sonair Sonair attenuates sound and is extremely quiet in operation. The appliance is mounted on the wall. With two types of air supply units (wall-mounted or mounted behind a radiator), Brink Climate Systems offers various solutions for dwellings and schools. These units are sound attenuating and Air supply unit Innoventus Innoventus ensures the demand-controlled supply of fresh, filtered outdoor air. The appliance is mounted behind a radiator. extremely quiet in operation. They also filter outdoor air and ventilate without draughts. With continuous, balanced mechanical extract from the wet rooms, a healthy and comfortable indoor climate is guaranteed. 4

BASIC DIAGRAM AIR SUPPLY UNITS Sonair A + Sonair F + Innoventus TECHNICAL SPECIFICATIONS AIR SUPPLY UNITS Appliance type Sonair ACC Innoventus ACC Dimensions H x W x D [mm] 455 x 310 x 134 370 x 410 x 142 Housing Synthetic, colour white Metal, colour white (RAL 9003) (RAL 9010) Power supply [V~/Hz] 230/50 230/50 Ventilation capacity Max. flow rate 62.5 dm 3 /s Max. flow rate 62.5 dm 3 /s (225 m 3 /h) with G3 filter, (225 m 3 /h) with G3 filter, continuously adjustable on the continuously adjustable on the Control Panel Control Panel Rated power [W] 9.6 at 17 dm 3 /s (60 m 3 /h) 9.6 at 17 dm 3 /s (60 m 3 /h) 52.3 at 62.5 dm 3 /s (225 m 3 /h) 52.3 at 62.5 dm 3 /s (225 m 3 /h) White mains cable [m] 1.80 1.80 and comfortable imate guaranteed AIR FILTERING The air supply units Sonair and Innoventus come standard with a filter (class G3). This filter is used in conditions with normal dust levels. The G3 filter removes 70 to 85% of the particles larger than10 μm, including sand, fabric fibres, pollen, hairs and spores. It is also possible to fit Sonair and Innoventus with filters (F6) which can filter extremely small dust particles. SONAIR ACC The air supply units Sonair A + and F + guarantee a demand-controlled supply of fresh, filtered outdoor air. Sonair is mounted on the inside of an exterior wall. Sonair sucks in outdoor air through a wall sleeve. The fan is mounted in a sound-absorbing chamber, which absorbs outdoor and fan noise. The fresh air is blown vertically into the room through a filter, resulting in a healthy and comfortable indoor climate. The rate at which fresh air is supplied is controlled by pushing buttons on the top of the unit or by using the control panel. INNOVENTUS ACC The Innoventus guarantees a demand controlled supply of fresh, filtered outdoor air. It differs from the Sonair in that the Innoventus is mounted behind a radiator. Like Sonair, Innoventus has excellent sound proofing characteristics and sucks in fresh outdoor air through the wall sleeve. The fresh air is blown vertically into the room through a filter, resulting in a healthy and comfortable indoor climate. There are no controls on the Innoventus appliance itself. The air supply rate is controlled by a control panel. FILTER COMPARISON Filter G3 G3K* F6 F9K* Dust (10 μm) Fine dust (2.5 μm) Pollen Spores Hairs Sand Textile threads Cement dust Bacteria Odour * Only available for Sonair = good = very good 5

A ven An extensive range of accessories makes it possible to integrate ACC into nearly all types of dwellings and schools. In addition to the air supply units Sonair and Innoventus, the ACC system requires the ACC control panel, the ACC CME unit and one or more ACC CO 2 sensors. An extensive range of wall From top to bottom: The ACC Control Panel, the ACC CME unit and the ACC CO 2 sensor. sleeves, grilles and other accessories makes it possible to integrate ACC into nearly all types of dwellings and schools. 6

gecertificeerd TECHNICAL SPECIFICATIONS SYSTEM ELEMENTS Technical specifications Control Panel CO 2 sensor Dimensions Ø x D [mm] Ø 100 x 30* Ø 100 x 25* Power supply [V~/Hz] 230/50 230/50 * Mounting in standard junction box 40 mm minimum TECHNICAL SPECIFICATIONS ACC EXHAUST BOX Technical specifications ACC exhaust box Dimensions H x W x D [mm] 260 x 380 x 340 Power supply [V~/Hz] 230/50 (1 phase with europlug) Sound pressure level [db(a)] 28 at 75 m 3 /h, 20 Pa Rated power Max. 55 at 300 m 3 /h Maximum ventilation capacity 440 m 3 /h at 150 Pa MILIEUZORG 001 ISO 14001 MILIEU MILIEU Brink Climate Systems, member of Centrotec Group, develops and produces high-quality climate control systems. These systems can be found all over the world in dwellings, office buildings, health centres, sports centres, schools, workshops, showrooms and production halls. LEDs on the sensor itself informs the user about the indoor air quality, without having to walk to the Control Panel. whole-house tilation system MAINS FILTER The ACC system must be fitted with a mains filter to comply with mandatory EMC requirements. The mains filter keeps the powerline signal within the dwelling and contributes to reliable communication. In new buildings the ACC system must be connected to its own mains group to exclude external interference sources. The mains filter is available in a surface-mounted version and in version for mounting on a DIN rail. CONTROL PANEL The Control Panel is the heart of the ACC system. The required ventilation times and rates can be programmed using a rotary ring and push buttons and a simple menu structure in the Control Panel. A boost function makes it possible for users to boost the central mechanical extract for 30 minutes when cooking or having a shower. EXTRACTION UNIT The special ACC central mechanical extract (CME) unit is an integrated part of the ACC system. This ACC CME unit is characterized by a high ventilation capacity, extremely quiet operation and an optional wired or RF boost switch. ACCESSOIRES An extensive range of accessories are available for the ACC system. Rigid and flexible wall sleeves are available depending on the required sound proofing through the wall. The wall grilles are available in round, square or wall brick designs. Side or top connections are available for situations where there is insufficient room to install the Sonair. CO 2 SENSOR The CO 2 sensor measures the air quality in the habitable room and can be used to automatically control the ventilation rate. This guarantees a good indoor air quality and maximum energy savings. The CO 2 level is displayed on the Control Panel. The sensor Various wall grilles are available for the ACC system. 7

Tel :0579336999 Mob:0876427830 Emai l :i nf o@f l ynnheat r ecover y. com Web:www. f l ynnheat r ecover y. com