Ontario Fire Code SECTION 5.11 COMBUSTIBLE FIBRES. Illustrated Commentary. Office of the Ontario Fire Marshal

Similar documents
Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Overview of Hotel Fire Safety Requirements

HealthandSafetyOntario.ca. Introduction. Storage Containers. Storing Flammable Liquids

Flammable Liquids Storage

Flammable Liquids Storage

Excerpts from the Canadian National Building Code (NBC)

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

HOT WORK PERMIT PROGRAM TRAINING. John Braun

Warehouse Checklist. Warehouse Construction

Insight. Storage Fires. Balanced Risk Engineering Solutions. Understanding the Risk. Commodity Classification. Storage Configuration

General Fire Code Requirements Within Commercial Tenant Spaces

ALVERNIA UNIVERSITY OSHA REGULATION: 29 CFR WELDING, CUTTING, AND BRAZING ( HOT WORK ) SECTION: 3600

An inventory of hazardous materials used in your workplace will prove useful.

How To Build A Two Hour Firewall In Calgary

SECTION 903 AUTOMATIC SPRINKLER SYSTEMS

We hope these Frequently Asked Questions will be of use both to municipal officials and fire inspectors.

CONSTRUCTION FIRE SAFETY PLANNING GUIDELINES

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS November 2011

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS. 1. All Floors (inspect from top floor to basement): Yes No

Certification: Building Plans Examiner. Exam ID: B3

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

FIRE AND LIFE SAFETY REQUIREMENTS FOR CONVENTIONS, TRADE SHOWS AND EXHIBITS

Fire Safety Requirements for Child Care Centre

Fire-Rated Glass and Glazing START

FLAMMABLE AND COMBUSTIBLE LIQUIDS. n OSHA Changes

A Code Review for Emergency Generators and Indoor Use of Portable Generators

#506 New Multi-Family Buildings & Additions Plan Intake Submittal Checklist

Important Ontario Fire Code Information for Building Owners in the City of Windsor

FIRE SAFETY SELF-INSPECTION FORM FOR CULTURAL INSTITUTIONS

Indiana Building Rehabilitation Standard

Terms and Definitions In Canada

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

Fire Safety In High Rise Building

Executive Summary Inclusion of Current Firewall Requirements in NBCC

FIRE-RESISTANCE-RATED CONSTRUCTION

- 5 - Table1. Maximum Compartment Volumes

FIRE-RESISTANCE-RATED CONSTRUCTION

FIRE SAFETY ONLINE TRAINING

Exit Routes, Emergency Action Plans, Fire Prevention Plans, and Fire Protection. OSHA Office of Training and Education 1

Proposed Residential Complex At Holding No. - 98, B.T. Road, Kolkata Developer Premier Mica Mining And Manufacturing Company

CHAPTER 9 FIRE PROTECTION SYSTEMS

Decree of the Ministry of the Environment. on fire safety of garages

The Commonwealth of Massachusetts Executive Office of Public Safety Department of Fire Services

General Safety & Health Standards Published by the Division of Building Safety In Cooperation with the Idaho Industrial Commission

Law No. (9) of 2012 Amending some provisions of Law No. (13) of 1997 Concerning the Civil Defense

Flammable Liquids 29 CFR

Queen's University Environmental Health and Safety

HOT WORK PERMIT PROCEDURES

A. Fire Protection Plan. B. Access and Parking

Fire Safety Risk Assessment Checklist for Residential Care Premises

c. As mandated by law, facilities must obtain and maintain valid zoning permits as well as permits for intended use.

Town of Horseheads Code Enforcement Vacant and At- Risk Property Registration

FIRE SAFETY HANDBOOK

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

Number of Sides Required to Have a Handrail

Flammable liquid classes: Combustible Liquid Classes. Class IC. Class II. Class IB F.P. below 22.8 C (73 F), boiling point at or above 37.

Safe Operating Procedure

BUILDING INSPECTORS INSPECTION FORM FOR CHILD CARE CENTERS

Errata has been identified as follows:

CHILD CARE CENTER INFORMATION SHEET

FLAMMABLE AND COMBUSTIBLE LIQUIDS

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Firefighter Review. Instructor Guide

Static Electricity. A Health and Safety Guideline for Your Workplace. What Are Some Sources of Static Electricity? What is Static Electricity?

SCHOOL FIRE AND LIFE SAFETY INSPECTION CHECKLIST

Ethanol Vehicle and Infrastructure Codes and Standards Citations

GENERAL FIRE SAFETY TERMS & DEFINITIONS

Building Code Clarifications - 7. Fire Resistance

THE FACTORIES A D OTHER PLACES OF WORK ACT (Cap 514)

Educational. Educational-Existing 1/28/2014. OCCUPANT LOADS [no change] Application. Application

Requirements for Hydrogen Storage and Use

Fire Alarm System Standpipes Sprinkler Systems Fire Drills Commercial Cooking Hood and more

city of edmonds development information

Ontario Association of Fire Chiefs Position Paper Residential Fire Sprinklers

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

Guidance on the use of Marquees, Tents and other Temporary Structures

Minnesota State Department of Public Safety

Building Codes Update: The 2009 International Fire Code and the Apartment Industry

MINIMUM STANDARDS FOR HIGH-RISE BUILDINGS

St. John s University

How To Write A Fire Risk Assessment

Area of Rescue Assistance Communication System ADA Code Applicable excerpts:

Denver Fire Department Idle Pallet Storage Guidelines Per NFPA 13_Chpt 12

Medicine Hat Fire Department. Special Event Requirements. medicinehat.ca/fire. August 2012

Fire Alarm Systems Requirements by Occupancy Type

Name Of Occupancy Date. Yes No Describe

GENERAL + MEANS OF ESCAPE (Part One) By Mdm Eng Yew Hoon (SIA)

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

The Accord on Fire and Building Safety in Bangladesh Building Standard

EMERGENCY ACTION, EVACUATION AND FIRE PREVENTION SAFETY PROGRAM

UCL FIRE RISK ASSESSMENT POLICY& ARRANGEMENTS

ALBERTA FIRE CODE SAFETY EQUIPMENT MAINTENANCE REQUIREMENTS

Tremco Fire Protection Systems Group Technical Bulletin

February 2014 Alberta Fire Code Page 1 of 5. Fire Safety and Hand Hygiene in Healthcare Facilities

Fire Safety Risk Assessment

Walking and Working Surface Checklist:

Monthly Warehouse Inspection Checklist

Action required (Please tick) If you answered YES, record Action Points at STEP 4

Module 5. Fire and Emergency Alarm System Part I- Basics

Transcription:

Ontario Fire Code SECTION 5.11 COMBUSTIBLE FIBRES Illustrated Commentary Office of the Ontario Fire Marshal

Combustible Fibres Illustrated Commentary 1 5.11.1. Storage Building sizes 5.11.1.1. Buildings used for the storage and handling of baled combustible fibres shall comply with the height and area limitations of the Building Code for Group F Division 2 occupancies. The Building Code classifies industrial occupancies into 3 divisions. These include: High Hazard Group F Division 1, Medium Hazard Group F, Division 2, and Low Hazard Group F, Division 3. Even though warehouses are classified as Group F, Division 2 or 3, depending upon their combustible loading, the Fire Code classifies a building containing combustible fibres as a Group F, Division 2 occupancy because of the inherent flash fire hazard. Application of this requirement is intended to prevent or minimize fire spread and collapse caused by a fire. To apply this requirement, refer to the applicable articles contained in subsection 3.2.2. of the Building Code that apply to Group F, Division 2 structures. Building means any structure used or intended for supporting or sheltering any use or occupancy. Building Code means the Ontario Building Code made under the Building Code Act or a predecessor to that Act. Combustible fibres means finely divided combustible vegetable or animal fibres and thin sheets or flakes of such materials that in a loose, unbaled condition present a flash fire hazard, and includes cotton, wool, hemp, sisal, jute, kapok, paper and cloth. Occupancy means the use or intended use of a building or part thereof for the shelter or support of persons, animals or property.

2 Illustrated Commentary Combustible Fibres 5.11.1 Storage Loose fibre storage 5.11.1.2.(1) Up to 3 m 3 of loose combustible fibres may be kept in any building provided storage is in a container complying with Article 2.4.1.9. and 2.4.1.10. (2) Quantities of loose combustible fibres exceeding 3 m 3 but not exceeding 15 m 3 shall be stored in rooms separated from the remainder of the building by a fire separation having a 1-hr fireresistance rating. (3) Quantities of loose combustible fibres exceeding 15 m 3 but not exceeding 30 m 3 shall be stored in rooms separated from the remainder of the building by a fire separation having a 2-hr fireresistance rating. (4) Quantities of more than 30 m 3 of loose combustible fibres shall not be stored in an individual room unless the room is sprinklered and separated from the remainder of the building by a fire separation having a 2-hr fire-resistance rating. Recognizing that combustible fibres may be present in a loose condition, the measures outlined in this requirements are intended to minimize damage that may result in the event of a fire. This is accomplished by limiting the quantities of loose combustible fibres permitted in a building based upon the level of protection provided. Quantity permitted 4. Stored in room with a 2 hour fireresistance rating and sprinklered. 3. Stored in room with a 2 hour fireresistance rating. 2. Stored in room with a 1 hour fireresistance rating. 1. Stored in a container conforming to Articles 2.4.1.9. and 2.4.1.10. Protection provided Building means any structure used or intended for supporting or sheltering any use or occupancy. Combustible fibres means finely divided combustible vegetable or animal fibres and thin sheets or flakes of such materials that in a loose, unbaled condition present a flash fire hazard, and includes cotton, wool, hemp, sisal, jute, kapok, paper and cloth. Fire separation means a construction assembly that acts as a barrier against the spread of fire and may or may not have a fire-resistance rating or a fire-protection rating. Fire-resistance rating means the time in hours or fraction thereof that a material or assembly of materials will withstand the passage of flame and the transmission of heat when exposed to fire under specified conditions of test and performance criteria, or as determined by extension or interpretation of information derived therefrom as prescribed in the Building Code. Sprinklered (as applying to a building or part thereof) means that the building or part thereof is equipped with a system of automatic sprinklers.

Combustible Fibres Illustrated Commentary 3 5.11.1. Storage Baled fibre storage 5.11.1.3.(1) Baled combustible fibres shall be stored so that (a) a single pile will not contain more than 700 m 3, (b) the maximum height of any single pile will not exceed 4.5 m, (c) piles are separated by aisles not less than 1.5 m wide, and (d) the clearance between piles and building walls is not less than 1 m. Clauses (a) (b) and (c) are intended to facilitate fire fighting efforts by limiting the fire load in any particular pile and providing access to the piles. Clause (d) is intended to prevent structural failure of the walls caused by the expansion of the baled fibres when they become wet. 700 m 3 (a) 4.5 m (b) 1.0 m (d) 1.5 m (c) Building means any structure used or intended for supporting or sheltering any use or occupancy. Combustible fibres means finely divided combustible vegetable or animal fibres and thin sheets or flakes of such materials that in a loose, unbaled condition present a flash fire hazard, and includes cotton, wool, hemp, sisal, jute, kapok, paper and cloth.

4 Illustrated Commentary Combustible Fibres 5.11.1. Storage Baled storage piles 5.11.1.4. The sides of baled storage piles shall be inclined back from the base of the pile with a slope of not less than 1 m for each 10 m of height. Baled combustible fibres will expand when they become wet and may become unstable. Some combustible fibres may absorb their own weight in water. It is important therefore to arrange the storage piles in an inclined manner. This will reduce the likelihood of the pile collapsing. This would require the setback of 0.45 meters for a pile having a maximum height of 4.5 meters.

Combustible Fibres Illustrated Commentary 5 5.11.1. Storage Baled storage piles 5.11.1.5.(1) The clearance between the sprinkler head deflectors and the tops of piles shall not be less than 457 mm. (2) Where the storage piles are above the lower chords of floor or roof structural framing members, a horizontal clear space of 300 mm shall be maintained between the storage and the structural members. Sentences (1) and (2) are intended to ensure that water discharging from automatic sprinklers or from a hand-held hose is not obstructed by the stored baled materials. Sprinkler deflectors 300 mm 457 mm Lower chord of floor or roof

6 Illustrated Commentary Combustible Fibres 5.11.1. Storage Heating equipment 5.11.1.6.(1) Storage areas for combustible fibres shall not contain fuel fired appliances or electrical heating elements. (2) Shields shall be provided that will prevent stored material from coming within 300 mm of any part of the heating system. These requirements are intended to minimize the possibility of heating equipment becoming a source of ignition in areas where combustible fibres are stored. Shields Heating appliances must be situated in a different room Appliance means a device to convert fuel into energy, and includes all components, controls, wiring and piping required to be part of the device by the applicable standard referred to in this Code. Combustible fibres means finely divided combustible vegetable or animal fibres and thin sheets or flakes of such materials that in a loose, unbaled condition present a flash fire hazard, and includes cotton, wool, hemp, sisal, jute, kapok, paper and cloth.

Combustible Fibres Illustrated Commentary 7 5.11.2. Fire Protection Standpipe and hose system installations 5.11.2.1. Combustible fibres shall be stored only in warehouses which are protected by standpipe and hose systems installed in conformance with the Building Code. Since a fire involving combustible fibres has the potential to spread rapidly, it is mandatory for a warehouse containing stored combustible fibres to be equipped with a fire standpipe system. A standpipe system conforming to the Building Code would provide the necessary water supply, fire hoses and related equipment that would be used to fight a fire. Building Code means the Ontario Building Code made under the Building Code Act or a predecessor to that Act. Combustible fibres means finely divided combustible vegetable or animal fibres and thin sheets or flakes of such materials that in a loose, unbaled condition present a flash fire hazard, and includes cotton, wool, hemp, sisal, jute, kapok, paper and cloth.

8 Illustrated Commentary Combustible Fibres 5.11.2. Fire Protection Portable extinguishers 5.11.2.2. Portable extinguishers shall be provided in conformance with Section 6.2. This requirement is a reminder to owners that portable fire extinguishers must be provided as required by Section 6.2.

Combustible Fibres Illustrated Commentary 9 5.11.2. Fire Protection Smoke vents 5.11.2.3. Where combustible fibres are stored in buildings, automatic smoke venting hatches manually operable from remote locations and having a combined opening area of 64 cm 2 for each square metre of floor area shall be provided. Smoke venting hatches let smoke and hot gases escape from a building to allow more effective manual fire fighting. Typically, local smoke detectors or fusible links are the devices used to automatically open smoke vents in the vicinity of the fire. The smoke venting hatches must also be manually operable from remote locations. The combined size of the smoke venting hatches is determined by the size of the building floor area (64 cm 2 for each square metre of floor area). For example, a floor area of 1000 square metres would require 6.4 square metres of smoke venting. Building Code means the Ontario Building Code made under the Building Code Act or a predecessor to that Act. Combustible fibres means finely divided combustible vegetable or animal fibres and thin sheets or flakes of such materials that in a loose, unbaled condition present a flash fire hazard, and includes cotton, wool, hemp, sisal, jute, kapok, paper and cloth. Floor Area means the space on any storey of a building between exterior walls and required firewalls and includes the space occupied by interior walls and partitions, but does not include exits and vertical service spaces that pierce the storey.

10 Questions and References Combustible Fibres Q1 A1 What is meant by combustible fibres? Combustible fibres means finely divided combustible vegetable or animal fibres and thin sheets or flakes of such materials that in a loose, unbaled condition present a flash fire hazard, and includes cotton, wool, hemp, sisal, jute, kapok, paper and cloth. Q2 How should baled combustible fibres be stored? A2 Refer to Ontario Fire Code 5.11.1.3. to 5.11.1.5. Q3 Should storage areas for combustible fibres contain electrical heating elements or fuel fired appliances? A3 Refer to Ontario Fire Code 5.11.1.6. Q4 What is the purpose of the standpipe and hose system with respect to combustible fibres? A4 Refer to Ontario Fire Code 5.11.2.1. Q5 What is the purpose of smoke vents in buildings where combustible fibres are stored? A5 Refer to Ontario Fire Code 5.11.2.3.