How to Reduce Your Lab s Capital & Operating Costs

Similar documents
VAV Laboratory Room Airflow The Lowdown on Turndown

Metrics That Matter: Pam Greenley MIT EHS Associate Director Steve Lanou MIT Deputy Director, Sustainability

Sustainable Smart Laboratories

Metrics for Energy Efficiency

SAM HOUSTON STATE UNIVERSITY

The Green Labs Symposium Driving Lab Sustainability in the Boston Area

Raising the Bar: A Comparison Study of Iowa s Current and Proposed Energy Code

Continuous Energy Management at UC San Diego. Anna Levitt, P.E. Assistant Energy Manager June 13, 2013

HVAC Systems in Schools & Commercial Buildings and Radon

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

Energy-Efficient Laboratory Design

Top 10 Energy Efficiency Opportunities

ASHRAE Rocky Mountain Chapter. RickPhillips Phillips, P.E., PE LEED AP Senior Mechanical Engineer The RMH Group, Inc.

IES <Virtual Environment> training. Trainee notes. ASHRAE 90.1 Appendix G - PRM Navigator. Version

HVAC Systems and Indoor Air Quality. Douglas K. Spratt, M.Sc., P.Eng.

PERCENT OUTDOOR AIR (%OA) CALCULATION AND ITS USE

Advanced Energy Design Guide LEED Strategies for Schools. and High Performance Buildings

85 F 80 F 50% 75 F 70 F 73.0/ F 10% Figure 1

DATA CENTER COOLING INNOVATIVE COOLING TECHNOLOGIES FOR YOUR DATA CENTER

SPECIAL ISSUE: NATIONAL SCIENCE FOUNDATION WORKSHOP

High Altitude HVAC. Silvertip Integrated Engineering Consultants

Case Studies: Infrared Heating in Industrial Applications

Example Retrocommissioning Measure: Opening Throttled Discharge Valves

Met r i c s a n d Ben c h M a r k s f o r ene r g y efficiency in LaB o r a t o r i e s

Dr. Michael K. West, PE 1 Dr. Richard S. Combes, PE 2 Advantek Consulting / Melbourne, Florida

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

HVAC. Kitchen Exhaust. rooftop equipment! let s drop on a few exhaust fans! it doesn t get easier!

SIMULATION OF RADIANT COOLING PERFORMANCE WITH

APPLICATION GUIDE. Comparison of Latent Cooling Performance of Various HVAC systems in a Classroom Application

HVAC Technologies for Building Energy Efficiency Improvements 2013 National Symposium on Market Transformation. Richard Lord Carrier Fellow

CETA Application Guide for the Exhaust System Requirements of Class II, Type B Biosafety Cabinets CAG March 24, 2010

Geothermal Heat Pumps: A Pathway to Zero Net Energy (ZNE) for Schools, Homes and Businesses

Liquid Cooling Solutions for DATA CENTERS - R.M.IYENGAR BLUESTAR LIMITED.

Dual Maximum VAV Box Controls

CURBING THE COST OF DATA CENTER COOLING. Charles B. Kensky, PE, LEED AP BD+C, CEA Executive Vice President Bala Consulting Engineers

Building Energy Analysis Report

The ASHRAE HQ Building Can the energy efficiency of the different mechanical systems really be compared? RESIDENTIAL LIGHT COMMERCIAL COMMERCIAL

ENHANCED LABORATORY HVAC SYSTEM

Preliminary Final Proposal

FLORIDA SOLAR ENERGY CENTER

Ventilation Standard For Health Care Facilities

Air Side Economizers and Energy Recovery - Improvements and New Regulations. Richard Lord

The New Data Center Cooling Paradigm The Tiered Approach

ULTRA-EFFICIENT HVAC DESIGN AND CONTROL

Selecting the Supply Air Conditions for a Dedicated Outdoor Air System Working in Parallel with Distributed Sensible Cooling Terminal Equipment

An energy and economic modeling study of exhaust ventilation systems compared to balanced ventilation systems with energy recovery

How to Build a Data Centre Cooling Budget. Ian Cathcart

290 Pratt St LLC, Connecticut's Department of Energy and Environmental Protection (DEEP) and Lockheed Martin. Powered for Progress

HPPR Data Center Improvements Projects Towards Energy Efficiency (CFD Analysis, Monitoring, etc.)

Presentation Outline. Common Terms / Concepts HVAC Building Blocks. Links. Plant Level Building Blocks. Air Distribution Building Blocks

Walking the Walk. case Study Science & Technology Facility

LOW-PRESSURE-DROP HVAC DESIGN FOR LABORATORIES

Arizona State University. Understanding the Impact of Urban Heat Island in Phoenix

10/9/2012. Poultry Farm Water Supply. Alabama Burglar & Alarm System. Industry Upgrades. Drinkers Fans Water Supply

Benefits of. Air Flow Management. Data Center

6 MECHANICAL HVAC SYSTEMS

Free Cooling in Data Centers. John Speck, RCDD, DCDC JFC Solutions

Heating & Cooling Efficiency

Collaborative Laboratory Commissioning and Sustaining the Optimal Building. By E. Lon Brightbill, P.E Facility Dynamics

for K-12 School Buildings

HIGH PERFORMANCE CHILLED WATER SYSTEMS. EarthWise HVAC. EarthWise HVAC High Performance CHW Plants

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Data Centers WHAT S ONTHEHORIZON FOR NR HVAC IN TITLE ? SLIDE 1

Integrating Kitchen Exhaust Systems with Building HVAC

Air Conditioning in Green Office Buildings?

Data Center Optimization Services. Maximize Your Data Center

LABORATORY DESIGN HANDBOOK

Energy Efficient HVAC-system and Building Design

NFPA Combustible Dust Compliance and the Industrial Ventilation System

On-Bill Financing. Frank Spasaro. OBF Webinar June 29, 2010

University of Maryland s Gossett Field House College Park, MD

REAL OPERATING COST SAVINGS FROM RETRO- COMMISSIONING OPPORTUNITIES FOR SAVINGS IN ACADEMIC MEDICAL CENTERS

Improving Data Center Energy Efficiency Through Environmental Optimization

Centrifugal Fans and Pumps are sized to meet the maximum

Energy Efficiency in New and Existing Data Centers-Where the Opportunities May Lie

Commercial & Municipal Retrofit 2015 VFD Rebate

Using Simulation to Improve Data Center Efficiency

Using Simulation to Improve Data Center Efficiency

DEVELOPMENT OF AN OPEN SOURCE HOURLY BUILDING ENERGY MODELING SOFTWARE TOOL

Xcel Business Customers: Program and Rebate Summary

Economics of Passive Solar and Zero Energy Homes

Mechanical and Natural Ventilation

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

Re Engineering to a "Green" Data Center, with Measurable ROI

2006 Delta T Corporation dba Big Ass Fan Company

Business Energy Efficiency. Webinar August 29, 2012

COMPARATIVE LIFE-CYCLE ANALYSIS OF ENERGY-EFFICIENCY MEASURES AT TVA S CHATTANOOGA OFFICE COMPLEX: PHASE II RESULTS & FINAL DESIGN

CCC/IOU Energy Efficiency Partnership and Campus Budget Challenges

By Donald Fisher, P.Eng., Associate Member ASHRAE

A Design Guidelines Sourcebook January High Performance Laboratories

Relative Sensitivity based Fire Detection Systems used in High Density Computer Rooms with In-Row Air Conditioning Units

Optimizing Network Performance through PASSIVE AIR FLOW MANAGEMENT IN THE DATA CENTER

Enclosed Football Stadium Design History and Lessons Learned

Demand Based Static Pressure Reset Control for Laboratories

On-Demand Ventilation Energy Saving in Industrial Applications

Science and Technology Facility, L a b o r a t o r i e s f o r t h e 2 1 s t C e n t u r y : C a s e S t u d i e s.

Control of Computer Room Air Handlers Using Wireless Sensors. Energy Efficient Data Center Demonstration Project

34% 81% 84% 19% GOLD PROJECT HIGHLIGHTS. LEED Facts. Stubbs Laboratory

Energy Efficiency Analysis for a Multi-Story Commercial Office Building. (LG Multi V Water II Heat Recovery VRF System)

Measuring Power in your Data Center: The Roadmap to your PUE and Carbon Footprint

Transcription:

How to Reduce Your Lab s Capital & Operating Costs University California Irvine Grand Mosque, Mecca Bank of America Largest LEED Plat. UHN: MaRS TMDT MGM Macau Casino

Presentation Overview For Deep Energy Reduction! Introduce low flow lab design innovation! Introduce a new tool for lab energy analysis! Describe approaches/issues to safely hit 2 ACH! Explain Demand Based Control 1 st cost & energy savings impacts! Describe low ACH case studies! Analyze other innovative technologies

Low Flow/Energy Lab Design: A New Paradigm! A focus on max savings Not a grab bag of many ideas Focus on a few, high impact concepts! The foundation: Airflow reduction Airflow has greatest energy impact Can also reduce lab s first cost!! Need for a holistic approach to technologies Use energy models for first cost & energy impact Impact of low flow design & combining concepts often non-intuitive In God We Trust, All Others Must Provide Data!

Goal: Dramatically Reduce Lab Energy Use! Outside air use: Largest energy driver Reducing OA reduces many energy uses! New technologies can help: Demand Based Control of ACH Chilled beams! Plus codes/standards also changing New versions of NFPA 45, Z9.5, ASHRAE! Result: Dramatic cut in energy use Labs can often run as low as 2 ACH Vivariums can run as low as 4 to 8 ACH If these approaches are used a Net Zero lab is possible even in Abu Dhabi, although many would call that not just mission difficult but: Mission Impossible!

Holistic Strategies for Increased Savings! Individually evaluating systems is suboptimal DBC, chilled beams, hoods & heat recovery all interact! To optimize lab safety, first cost & energy: Combining systems based on analysis of Net benefits Also use a layered or pyramid approach: *Heat Recovery HR* Chilled Beams VAV Exh Fan Demand Based Control/ FH Min VAV Lab Control Recover some of heating and cooling energy Decouple heat load from ventilation flows VAV Exit Velocity Flow Reduce flow requirements Basic control approaches

Energy, First Cost, & Payback Analysis Tool! Lab focused design analysis Customized lab analysis engine Calculates both energy & 1 st cost Powerful What If tool for design! Reviewed & approved by utilities PG&E, S. Cal. Edison, Con Ed Calculates Rebate incentives! Validated by Emcor & JCI! Holistic broad range tool For many technologies & concepts Heat recovery, chilled beams, etc.

Toronto Example Analysis Assumptions! Model typical bldg. w/ 125K GSF Lab & lab support area: 50K NSF Office area: 30K NSF! Base dilution ventilation: Typically 6 to 12 ACH, assume avg. of 8! Energy Cost Assumptions: Electric: $0.13/kWh Avg Heating: $0.80/therm $800/kW Demand & $.1/m3 gas incentive! Low to moderate hoods: One 6 hood/ 667 ft. 2 module (75)! Manifolded exhaust fans: 4 fans are staged plus 1 spare

8 ACH Baseline Energy Costs For Toronto! Skin & solar gains typically small compared to OA! Base flow rate (including offices): 151.6K m 3 /hr day & 138K m 3 /hr night! Total baseline energy use is $474K/ year

Holistic Strategies for Increased Savings! Individually evaluating systems is suboptimal DBC, chilled beams, hoods & heat recovery! To optimize lab safety, first cost & energy: Combining systems appropriately is best Also use a layered or pyramid approach: *Heat Recovery HR* Chilled Beams VAV Exh Fan Demand Based Control/ FH Min VAV Lab Control Recover some of heating and cooling energy Decouple heat load from ventilation flows VAV Exit Velocity Flow Reduce flow requirements Basic control approaches

Achieving Down to 2 ACH Safely in Labs! Goal: Achieve 2 ACH day/night or 3-4 day / 2 night! What are the drivers of lab airflow that affect this? Hood flows, thermal loads & ACH rates Ventilation rate (cfm) VAV Hoods Min Flow VAV Supply Min Load Demand Based Control of ACH 2 ACH Min Hoods Thermal Load ACH / Dilution Requirement To achieve lab flows down to 2 ACH to reduce energy & 1 st cost, all flow requirements need to be reduced

Reducing the Fume Hood Flow Drivers! For low fume hood density: Use VAV hoods, low FV not required For poor sash behavior, use sash closers! For moderate density: Also use new ANSI Z9.5 fume hood min: Old 6 fume hood min was ~250 cfm New 6 fume hood min as low as ~100 cfm! For high hood density: Use VAV low FV hoods or VAV & sash closer Ability to hit 2/4 ACH depends on density Up to three 6 hoods per 900 ft 2 = 2 ACH Up to six 6 hoods per 900 ft 2 = 4 ACH For most labs: min hood flow < 2 to 4 ACH

What is the VAV Fume Hood Minimum Flow Rate? Flow in CFM 1000 800 600 400 200 0 Old Min (250 CFM) Fume Hood Exhaust 6" 18" Sash Position! Fume Hood Min: For VAV hoods Only affects hood flow for small or closed sash positions Independent of face velocity Changing min will not reduce face velocity Constant Volume Mode Variable Volume Mode

What is the VAV Fume Hood Minimum Flow Rate? Flow in CFM 1000 800 600 400 200 100 0 Old Min (250 CFM) Fume Hood Exhaust New min range down to ~100 CFM for 6 hood 2.4" 18" Sash Position! Fume Hood Min: For VAV hoods Only affects hood flow for small or closed sash positions Independent of face velocity Changing min will not reduce face velocity Constant Volume Mode Variable Volume Mode

Reducing the Fume Hood Flow Drivers! For low fume hood density: Use VAV hoods, low FV not required Helpful to use 18 design opening For poor sash behavior, use sash closers! For moderate density: Also use new ANSI Z9.5 fume hood min: Old 6 fume hood min was ~250 cfm New 6 fume hood min as low as ~100 cfm! For high hood density: Use VAV low FV hoods or VAV & sash closer Ability to hit 2/4 ACH depends on density Up to three 6 hoods per 900 ft 2 = 2 ACH Up to six 6 hoods per 900 ft 2 = 4 ACH For most labs: min hood flow < 2 to 4 ACH