LINE INTERACTIVE UPS OF 650VA CAPACITY WITH QUASI SINE WAVE OUTPUT TECHNICAL SPECIFICATIONS

Similar documents
TECHNICAL SPECIFICATIONS FOR 1.5 KVA ONLINE UPS

EXPRESSION OF INTEREST (EOI) 001/ DT

UNINTERRUPTIBLE POWER SUPPLIES >9900AUPS UNINTERRUPTIBLE POWER SUPPLIES

MAJORSINE Power Inverter

Always On UPS Systems Inc., # Campion Road, Kelowna, BC Canada V1X 7S8

SmartPro 230V 3kVA 2.25kW Line-Interactive UPS, Extended Run, SNMP, Webcard, Tower, USB, DB9 Serial

LTR Series Uninterruptible Power Systems 700 VA KVA. General Specification

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

SmartPro 230V 750VA 500W Line-Interactive Sine Wave UPS, SNMP, Webcard, Tower, USB, DB9 Serial

DC UPS. RTB.e A. IMB.e/ITB.e kva. E2001.e/E3001.e kva. Input voltage: 110/125/220 Vdc. 115/120/230 Vac, 1-phase (IMB.

PowerGem Pro Uninterruptible Power Supply

Audio/Video AVR Series UPS - Intelligent Automatic Voltage Regulated Power Management System

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

SmartOnline Expandable Rack / Tower UPS System Online, double-conversion protection for mission critical applications

SmartOnline V 6kVA 4.2kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 6U Rack/Tower, DB9 Serial, Hardwire

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

LAP ENERGIA PARA DATACENTERS

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Galleon 6-10K Online UPS. Voltronic Power Technology Corporation

Power Quality. Uninterruptible Power Supply

SmartPro 120V 500VA 300W Line-Interactive UPS, SNMP, Webcard, 1U Rack/Tower, USB, DB9 Serial

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

SmartOnline V 5kVA 4.5kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

Model #: SMART2200CRMXL

City of Leesburg, Florida I.T. Data Center APPENDIX A TOSHIBA UPS INFORMATION

SmartPro 100/110/120V 1.5kVA 900W Line-Interactive Sine Wave UPS, Tower, SNMP, Webcard, USB, DB9 Serial

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

Model #: SMART2200VS. 2200VA / 2.2kVA line interactive tower UPS. Maintains 120V nominal output over an input range of 79 to 147V

Liebert GXT MT+ CX UPS, 1000VA VA Intelligent, Reliable UPS Protection. AC Power for Business-Critical Continuity

Industrial Tower Uninterruptible Power Supply Specifications Bulletin Numbers 1609-P

SmartPro 230V 1000VA 900W Line-Interactive Sine Wave UPS, SNMP, Webcard, 2U Rack/Tower, USB, DB9 Serial

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

SmartPro 120V 2.2kVA 1.92kW Line-Interactive Sine Wave UPS, SNMP, Webcard option, 2U Rack/Tower, LCD, USB, DB9 Serial

Eaton 93PM UPS Where aesthetics meet intelligence.

Smart Pro Rack/Tower UPS Intelligent, line interactive network power management system

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 15kVA and 20kVA Smart-UPS RT 230VAC Uninterruptible Power Supply

Smart-UPS APC Smart-UPS 1000VA USB & Serial 230V

3U, 2200 VA Audio/Video Pure Sine Wave UPS System

Galaxy 7000: Unitary Specification guide: Single UPS, three-phase, 160 to 500 kva

Assembled in Florida, USA.

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

QuickSpecs. Models HP T1500 UPS JPN/TWN. HP UPS T1000 G2, T1500 G2 Models Overview

TIG INVERTER INSTRUCTION MANUAL

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Three-phase UPS DELPHYS MX from 250 to 900 kva the Mega Power protection up to 5.4 MVA

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 3000VA, 5000VA and 6000 VA Smart-UPS RT 230VAC Uninterruptible Power Supply

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Technical Data. back-up time in minutes 100% load % load

Uninterruptible Power Supply

PC Personal 120V 600VA 375W Standby UPS with Pure Sine Wave Output, Tower, 6 Outlets

TOSHIBA G /100/160/225 kva

Internet Office 500VA Tower Standby 120V UPS with USB port

VISION UPS UPS PRODUCT CATALOGUE

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 30 kva 30 kw

GE Digital Energy. TLE Series UPS kw three phase 400 Vac. with best-in-class efficiency. gimagination at work

LIBRA USV-Anlagen von EBT (10-800KVA) LIBRA pro. UPS kva three-phase / single-phase kva three-phase / three-phase.

Thyristor-controlled power supplies and battery chargers

BB800 Off-Grid Solar System

Single Output Switching Power Supply

NEW APC Smart-UPS. Advanced line interactive power protection for servers and network equipment. The world s most popular network and server UPS.

Uninterruptible power supplies Meissner. Efficient and reliable backup where electricity is critical to you

TLE Series UPS kva/kw three phase 400 Vac with best-in-class efficiency

User Manual 1K/2K/3K Online UPS

A COMPARISON OF TYPICAL UNINTERRUPTIBLE POWER SUPPLY (UPS) DESIGNS IN TODAY S MARKETS

Energy Management Energy Meter Type EM23 DIN

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

SG Series UPS kva three phase 400 Vac

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

Transformerless UPS systems and the 9900 By: John Steele, EIT Engineering Manager

Online UPS. PowerWalker VFI 1000R/1U

Eaton UPS kVA. Energía. 20 kva/18 kw and 30 kva/27 kw 0.9 power factor. True double-conversion online UPS.

TRAMS TROLLEY-BUSES SUBWAY

Remote Monitoring and REC 501 Control Unit Product Guide

RIELLO ELETTRONICA. Master HP

Specification Requirements DBL 700MX and 1000MX Series UPS

UNINTERRUPTIBLE POWER SUPPLY (UPS)

BC Pro UPS System Standby UPS System

Internet Office UPS System Standby UPS for PCs, workstations and more

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

on-line LOCAL AREA NETWORKS (LAN) SERVERS DATA CENTERS internet centers (isp/asp/pop) industrial plcs industrial applications

AIS 3000 APC AIS kVA 208V w/2 Batt. Module Exp. To 4, Start-Up 5X8, Internal Maintenance Bypass

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

Polyphase kwh Electricity Meter

GE Consumer & Industrial Power Protection UPS. Uninterruptible Power Supplies. GE imagination at work

PHOENIX CONTACT Features

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Rack mounted telephone- and leased line modem for industrial applications

The UPS for the highest security in industry and data centres

Internet Office 750VA Ultra-compact Standby 120V UPS with USB port

NO-BREAK KS 7e. Concentrated Energy kva (50Hz) 3000 kva (60Hz) DIESEL ROTARY UNINTERRUPTIBLE POWER SUPPLY SYSTEM

Liebert GXT3 Reliable On-Line UPS Protection In A Compact 2U Package 700VA -3000VA

SP SP SP SP SP SP /60 Hz +/- 0,5% instelbaar/selectable. 700Watt. max 810Watt.

Phase Modular Finally the benefits of Modular ups are for all

Low and High Voltage Power Supplies

zseries 18-Slot Chassis 18-Slot 3U PXI Express Chassis with AC Up to 8 GB/s

Stroom voor elke toepassing

Transcription:

Annexure-D1 LINE INTERACTIVE UPS OF 650VA CAPACITY WITH QUASI SINE WAVE OUTPUT TECHNICAL SPECIFICATIONS I. Test 1. Input AC Voltage 165V-265 V 2. Buck and Boost operation ± 12% 3. Output Voltage (Battery Mode) 230V ± 8% 4. Output frequency (Battery Mode) 50Hz ± 0.5% 5. Transfer Time (Mains to Battery and Battery to Mains) < 5ms 6. Capacity (in Watts) >360W 7. (i) Backup time on Full Load in Battery Mode >5 minutes (ii) Battery Energy Storage capacity (with original new SMF lead acid Batteries*) >84 Whr II. Other Requirements 1. Temperature and Humidity i) Operating Temperature Range upto 40 C ii) Humidity upto 95% Rh 2. Noise level (at 1 meter) 50dB 3. Conformance to Standards i) EMC Standards IEC 801-2,3,4,5 ii) Emission Standard EN55022 Class B iii) Safety Standard EN50091-1 4. Cold start feature at full load 5. Standard hardware / software support for serial communication interface 6. Free Software Package for advanced UPS Power Management and Diagnostics 7. Protection features including lightning and surge protection 8. Network grade line conditioning to prevent glitches 9. Intelligent Battery Management Feature 10. Three years Warranty Period for UPS and Battery *Provide the batteries of SMF type from the following manufacturer i.e Hitachi, Panasonic, Global Yuasa, Yuasa, Exide, CSB or Amar Raja

Annexure-D2 LINE INTERACTIVE UPS OF 1000VA CAPACITY WITH QUASI SINE WAVE OUTPUT I. Test TECHNICAL SPECIFICATIONS 1. Input AC Voltage 175V-275 V 2. Buck and Boost operation 12% 3. Output Voltage (Battery Mode) 230V ± 8% 4. Output frequency (Battery Mode) 50Hz ± 0.5% 5. Transfer Time (Mains to Battery and Battery to Mains) < 5ms 6. Capacity (in Watts) >600W 7. (i) Backup time on Full Load in Battery Mode >5 minutes (ii) Battery Energy Storage capacity (with original new SMF lead acid Batteries*) >216 Whr II. Other Requirements 1. Temperature and Humidity i) Operating Temperature Range Upto 40 C ii) Humidity Upto 95% Rh 2. Noise level (at 1 meter) 50dB 3. Conformance to Standards i) EMC Standards IEC 801-2,3,4,5 ii) Emission Standard EN55022 Class B iii) Safety Standard EN50091-1 4. Cold start feature at full load 5. Standard hardware / software support for serial communication interface 6. Free Software Package for advanced UPS Power Management and Diagnostics 7. Protection features including lightning and surge protection 8. Network grade line conditioning to prevent glitches 9. Intelligent Battery Management Feature 10. Three years Warranty Period for UPS and Battery *Provide the batteries of SMF type from the following manufacturer i.e Hitachi, Panasonic, Global Yuasa, Yuasa, Exide, CSB or Amar Raja

I. Test LINE INTERACTIVE UPS OF 1000VA CAPACITY WITH SINE WAVE OUTPUT TECHNICAL SPECIFICATIONS 1. Input AC Voltage 175V-275 V 2. Buck and Boost operation 12% 3. Output Voltage (Battery Mode) 230V ± 8% 4. Output frequency (Battery Mode) 50Hz ± 0.5% 5. Transfer Time (Mains to Battery and Battery to Mains) < 6ms 6. Capacity (in Watts) >600W 7. (i) Backup time on Full Load in Battery Mode >5 minutes (ii) Battery Energy Storage capacity (with original new SMF lead acid Batteries*) >168 Whr Annexure-D3 II. Other Requirements 1. Temperature and Humidity i) Operating Temperature Range Upto 40 C ii) Humidity Upto 95% Rh 2. Noise level (at 1 meter) 50dB 3. Conformance to Standards i) EMC Standards IEC 801-2,3,4,5 ii) Emission Standard EN55022 Class B iii) Safety Standard EN50091-1 4. Cold start feature at full load 5. Standard hardware / software support for serial communication interface 6. Free Software Package for advanced UPS Power Management and Diagnostics 7. Protection features including lightning and surge protection 8. Network grade line conditioning to prevent glitches 9. Intelligent Battery Management Feature 10. Three years Warranty Period for UPS and Battery *Provide the batteries of SMF type from the following manufacturer i.e Hitachi, Panasonic, Global Yuasa, Yuasa, Exide, CSB or Amar Raja

I. Test LINE INTERACTIVE UPS OF 1500VA CAPACITY WITH SINE WAVE OUTPUT TECHNICAL SPECIFICATIONS 1. Input AC Voltage 175V-275 V 2. Buck and Boost operation 12% 3. Output Voltage (Battery Mode) 230V ± 8% 4. Output frequency (Battery Mode) 50Hz ± 0.5% 5. Transfer Time (Mains to Battery and Battery to Mains) < 6ms 6. Capacity (in Watts) >900W 7. (i) Backup time on Full Load in Battery Mode >5 minutes (ii) Battery Energy Storage capacity (with original new SMF lead acid Batteries*) >216 Whr Annexure-D4 II. Other Requirements 1. Temperature and Humidity i) Operating Temperature Range Upto 40 C ii) Humidity Upto 95% Rh 2. Noise level (at 1 meter) 50dB 3. Conformance to Standards i) EMC Standards IEC 801-2,3,4,5 ii) Emission Standard EN55022 Class B iii) Safety Standard EN50091-1 4. Cold start feature at full load 5. Standard hardware / software support for serial communication interface 6. Free Software Package for advanced UPS Power Management and Diagnostics 7. Protection features including lightning and surge protection 8. Network grade line conditioning to prevent glitches 9. Intelligent Battery Management Feature 10. Three years Warranty Period for UPS and Battery *Provide the batteries of SMF type from the following manufacturer i.e Hitachi, Panasonic, Global Yuasa, Yuasa, Exide, CSB or Amar Raja

TECHNICAL SPECIFICATIONS Annexure-D5 1kVA UPS True On Line, Sine wave Output Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 180V-270V AC 2. Input Power Factor @ F.L > 0.95 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment Backup time Watt Hr. required 36V Bus 48V Bus For 30 min > 864 Watt Hr > 864 Watt Hr For 60 min > 1440 Watt Hr > 1440 Watt Hr 5. AC Output Voltage and steady state Regulation @ FL 230V AC; better than ± 1% 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power > 800W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 80% (ii) Mains mode > 80% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS

TECHNICAL SPECIFICATIONS 2kVA UPS True On Line, Sine wave Output Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 170V-270V AC 2. Input Power Factor @ F.L > 0.95 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment Backup time Watt Hr. required 48 V Bus 72 / 96 V Bus For 30 min > 2016 Watt Hr > 2304 Watt Hr For 60 min > 3120 Watt Hr > 3648 Watt Hr 5. AC Output Voltage and steady state Regulation @ FL 230V AC; better than ± 1% 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power > 1600W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 80% (ii) Mains mode > 80% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS

TECHNICAL SPECIFICATIONS 3kVA UPS True On Line, Sine wave Output Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 170V-270V AC 2. Input Power Factor @ F.L > 0.95 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment Backup time Watt Hr. required 96 V Bus 192 V Bus For 30 min > 2880 Watt Hr > 2880 Watt Hr For 60 min > 6240 Watt Hr > 4608 Watt Hr 5. AC Output Voltage and steady state Regulation @ FL 230V AC; better than ± 1% 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power > 2400W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 83% (ii) Mains mode > 85% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS

TECHNICAL SPECIFICATIONS 5kVA UPS True On Line, Sine wave Output Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 180V-270 V AC 2. Input Power Factor @ F.L > 0.95 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment Backup time For 30 min For 60 min Watt Hr. required 192 V Bus > 4608 Watt Hr > 7680 Watt Hr 5. AC Output Voltage and steady state Regulation @ FL 230V AC; better than ± 1% 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power >4000W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 87% (ii) Mains mode > 85% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS

TECHNICAL SPECIFICATIONS 10kVA UPS True On Line, Sine wave Output (3 ø i/p & 1 ø o/p) Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 374V-506 V AC 2. Input Power Factor @ F.L > 0.95 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment Backup time For 30 min For 60 min Watt Hr. required 240 V Bus > 9600 Watt Hr > 15600 Watt Hr 5. AC Output Voltage and steady state Regulation @ FL 230V AC; better than ± 1% 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power > 8000W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 84% (ii) Mains mode > 89% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS

TECHNICAL SPECIFICATIONS 10kVA UPS True On Line, Sine wave Output (1 ø i/p & 1 ø o/p) Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 180V-270 V AC 2. Input Power Factor @ F.L > 0.95 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment Backup time For 30 min For 60 min Watt Hr. required 240 V Bus > 9600 Watt Hr > 15600 Watt Hr 5. AC Output Voltage and steady state Regulation @ FL 230V AC; better than ± 1% 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power > 8000W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 84% (ii) Mains mode > 89% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS

TECHNICAL SPECIFICATIONS 15kVA UPS True On Line, Sine wave Output (3 ø i/p & 1 ø o/p) Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 415V ± 15% 2. Input Power Factor @ F.L > 0.93 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment Backup time For 30 min For 60 min Watt Hr. required 240 V Bus > 15600 Watt Hr > 24000 Watt Hr 5. AC Output Voltage and steady state Regulation @ FL 230V AC; better than ± 1% 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power > 12000W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 84% (ii) Mains mode > 89% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS

TECHNICAL SPECIFICATIONS 15kVA UPS True On Line, Sine wave Output (3 ø i/p & 3 ø o/p) Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 415V ± 15% 2. Input Power Factor @ F.L > 0.93 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment 5 a. AC Output Voltage and steady state Regulation @ FL 415V AC; < 1% (for balanced load) < 2% (for 100% unbalanced load) 5 b. Phase displacement < 1º (for balanced load) < 2º (for 100% unbalanced load) 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power > 12000W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 84% (ii) Mains mode > 89% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity Backup time For 30 min For 60 min Watt Hr. required 240 V Bus > 15600 Watt Hr > 24000 Watt Hr (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS

TECHNICAL SPECIFICATIONS 20kVA UPS True On Line, Sine wave Output (3 ø i/p & 1 ø o/p) Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 415V ± 15% 2. Input Power Factor @ F.L > 0.95 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment Backup time For 30 min For 60 min Watt Hr. required 240 V Bus > 15600 Watt Hr > 24000 Watt Hr 5. AC Output Voltage and steady state Regulation @ FL 230V AC; better than ± 1% 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power >16000W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 84% (ii) Mains mode > 89% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS

TECHNICAL SPECIFICATIONS 20kVA UPS True On Line, Sine wave Output (3 ø i/p & 3 ø o/p) Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 415V ± 15% 2. Input Power Factor @ F.L > 0.95 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment 5 a. AC Output Voltage and steady state Regulation @ FL 415V AC; < 1% (for balanced load) < 2% (for 100% unbalanced load) 5 b. Phase displacement < 1º (for balanced load) < 2º (for 100% unbalanced load) 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power > 16000W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 84% (ii) Mains mode > 89% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity Backup time For 30 min For 60 min Watt Hr. required 240 V Bus > 15600 Watt Hr > 24000 Watt Hr (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS

TECHNICAL SPECIFICATIONS 30kVA UPS True On Line, Sine wave Output (3 ø i/p & 1 ø o/p) Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 415V ± 15% 2. Input Power Factor @ F.L > 0.93 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment Backup time For 30 min For 60 min Watt Hr. required 360 V Bus > 28800 Watt Hr > 46800 Watt Hr 5. AC Output Voltage and steady state Regulation @ FL 230V AC; better than ± 1% 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power > 24000W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 84% (ii) Mains mode > 89% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS

TECHNICAL SPECIFICATIONS 30kVA UPS True On Line, Sine wave Output (3 ø i/p & 3 ø o/p) Technology PWM technology in True on-line operation, employing double conversion method using MOSFETs / IGBTs. Method of Inversion Adaptive pulse width modulation or weighted pulse width modulation with high Frequency switching (>10 khz for MOSFETs and >5kHz for IGBTs). Test Parameters 1. Input Voltage Range @ F.L 415V ± 15% 2. Input Power Factor @ F.L > 0.93 3. Input Frequency Variation 50 Hz ± 5% 4. Total Energy storage capacity of Battery (in one string) @ F.L and @ Non-A/C environment 5 a. AC Output Voltage and steady state Regulation @ FL 415V AC; < 1% (for balanced load) < 2% (for 100% unbalanced load) 5 b. Phase displacement < 1º (for balanced load) < 2º (for 100% unbalanced load) 6. Transient Voltage Regulation at Step Load < 5% 7. Maximum deliverable continuous Output Power > 24000W 8. Output Frequency 50 Hz 4% (Synchronous to mains) 50 Hz 0.5% (Free running) 9. Efficiency (i) Battery mode > 84% (ii) Mains mode > 89% 10. THD @ F.L < 3% (for linear load); < 5% (for nonlinear load) 11. Crest Factor @ F.L > 3 1 12. Over Load Duration @ 110%, 125% and 150% of F.L 5 min, 1 min and 2 sec respectively 13. Static bypass switch Bi-directional with change over time less than 10 milliseconds in free running mode and instantaneous in synchronous mode from Inverter to Bypass and vice-versa. 14. Temperature and Humidity Backup time For 30 min For 60 min Watt Hr. required 360 V Bus > 28800 Watt Hr > 46800 Watt Hr (i) Operating Temperature Range upto 40ºC (ii) Humidity upto 95% Rh 15. Noise level (at 1 meter) < 45 db 16. Conformance to Standards (i) EMC Standards IEC 801-2,3,4,5 (ii) Emission Standard EN55022 Class B (iii) Safety Standard EN 50091-1

Battery Charger Operation Float-cum-boost charger with automatic boost/trickle charger modes with current limiting features. It s characteristics shall be such as to match the float/ boost charging of the batteries as per battery characteristic, for battery life enhancement. High frequency chargers preferred. Protection Features a) Isolation - Output shall be fully isolated from mains and with surge /spike suppressors incorporated. b) Current limiting, over load and Short circuit protection. c) Phase locking mechanism with mains frequency. d) Over voltage / Under voltage protection. e) All other protection systems as required for safety of the system. Other Features 1. Cold start feature under full load condition. 2. Standard hardware / software support for serial communication interface and SNMP / Web monitoring. 3. Auto shut down and energy saving features. 4. Temperature compensated battery charging for battery life enhancement. 3. Automated battery testing and advanced battery management features. 4. Sufficient ventilation and forced air cooling through fans. 5. Documentation/Manuals support for component level Servicing. 6. Serviceability at component level. 7. Spares and accessories deliverable along with UPS for Servicing. Warranty and AMC 1. 3 years Warranty Period for UPS as well as Batteries. 2. Comprehensive AMC covering the batteries, after the expiry of warranty period for the configurations (i) to (iv) given below. Important instructions a) Separate quote is invited for each one of the following configurations (i) with built- in isolation transformer and 30 minutes back up time. (ii) with built- in isolation transformer and one hour back up time. (iii) with external isolation transformer and 30 minutes back up time. (iv) with external isolation transformer and one hour back up time. b) Batteries must be SMF type of following make Hitachi, Panasonic, Global Yuasa, Yuasa, Base or Rocket. c) Quote should indicate the Model/Series Name and Model Number of UPS