Design and Implementation of High Frequency Inductor for Simultaneous Hardening

Similar documents
Theory of Heating by Induction

Inductors & Inductance. Electronic Components

Circuits with inductors and alternating currents. Chapter 20 #45, 46, 47, 49

Edmund Li. Where is defined as the mutual inductance between and and has the SI units of Henries (H).

1. The diagram below represents magnetic lines of force within a region of space.

Application Note. So You Need to Measure Some Inductors?

Impedance Matching and Matching Networks. Valentin Todorow, December, 2009

6 ELECTRICAL PARAMETERS

An equivalent circuit of a loop antenna.

DC GENERATOR THEORY. LIST the three conditions necessary to induce a voltage into a conductor.

Iron Powder Cores for Switchmode Power Supply Inductors. by: Jim Cox

Objectives. Capacitors 262 CHAPTER 5 ENERGY

Induced voltages and Inductance Faraday s Law

ElectroMagnetic Induction. AP Physics B

Selecting IHLP Composite Inductors for Non-Isolated Converters Utilizing Vishay s Application Sheet

Direction of current flow through conductor. Fig. 1 Magnetic field generated by current flow

Module 2.2. Heat transfer mechanisms

Planar versus conventional transformer

DIRECT CURRENT GENERATORS

Motor-CAD Software for Thermal Analysis of Electrical Motors - Links to Electromagnetic and Drive Simulation Models

Voltage Loss Formula s

Introduction to Electricity & Magnetism. Dr Lisa Jardine-Wright Cavendish Laboratory

Human Exposure Limits

Vrieswijk, T & Srinivasan,A Amerongen,NL, 25 januari 2012

April 1. Physics 272. Spring Prof. Philip von Doetinchem

CHAPTER 4 DESIGN OF INTEGRAL SLOT AND FRACTIONAL SLOT BRUSHLESS DC MOTOR

Human Exposure to Outdoor PLC System

Improved PFC Boost Choke using a Quasi-Planar Winding Configuration Dave Shonts Schott Corporation 1000 Parkers Lake Road Wayzata, MN 55391

Objectives 200 CHAPTER 4 RESISTANCE

45. The peak value of an alternating current in a 1500-W device is 5.4 A. What is the rms voltage across?

BASIC ELECTRONICS AC CIRCUIT ANALYSIS. December 2011

Coupling Effect in Substation Ground Measurements

ENERGY CARRIERS AND CONVERSION SYSTEMS Vol. II - Liquid Hydrogen Storage - Takuji Hanada, Kunihiro Takahashi

2. A conductor of length 2m moves at 4m/s at 30 to a uniform magnetic field of 0.1T. Which one of the following gives the e.m.f. generated?

EXPERIMENTAL ANALYSIS OF HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE WITH DIFFERENT TWIST RATIO OF TWISTED TAPE INSERTS

Chapter 11. Inductors ISU EE. C.Y. Lee

Contactless Power Transfer : Inductive charging of EV

Energy and Energy Transformations Test Review

UNDERSTANDING AND CONTROLLING COMMON-MODE EMISSIONS IN HIGH-POWER ELECTRONICS

Line Reactors and AC Drives

Welding of Plastics. Amit Mukund Joshi. (B.E Mechanical, A.M.I.Prod.E)

Expansion and Implementation of a 3x3 Sobel and Prewitt Edge Detection Filter to a 5x5 Dimension Filter

Active noise control in practice: transformer station

Diodes have an arrow showing the direction of the flow.

The purposes of this experiment are to test Faraday's Law qualitatively and to test Lenz's Law.

13 ELECTRIC MOTORS Basic Relations

1. At which temperature would a source radiate the least amount of electromagnetic energy? 1) 273 K 3) 32 K 2) 212 K 4) 5 K

Consideration of a high-capacity foil cable:

Indiana's Academic Standards 2010 ICP Indiana's Academic Standards 2016 ICP. map) that describe the relationship acceleration, velocity and distance.

Radiant Temperature Sensor TY7321

CHAPTER - 1. Chapter ONE: WAVES CHAPTER - 2. Chapter TWO: RAY OPTICS AND OPTICAL INSTRUMENTS. CHAPTER - 3 Chapter THREE: WAVE OPTICS PERIODS PERIODS

ELECTRON SPIN RESONANCE Last Revised: July 2007

A METHOD OF CALIBRATING HELMHOLTZ COILS FOR THE MEASUREMENT OF PERMANENT MAGNETS

A wave lab inside a coaxial cable

Coupled Inductors. Introducing Coupled Inductors

1150 hp motor design, electromagnetic and thermal analysis

Product Specification

Solution Derivations for Capa #11

Inductors. AC Theory. Module 3

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

EFFECT OF OBSTRUCTION NEAR FAN INLET ON FAN HEAT SINK PERFORMANCE

Calculating Heat Loss by Mark Crombie, Chromalox

Chapter 10. AC Inductor Design. Copyright 2004 by Marcel Dekker, Inc. All Rights Reserved.

PHYS 222 Spring 2012 Final Exam. Closed books, notes, etc. No electronic device except a calculator.

Forms of Energy. Freshman Seminar

Welding. Module

iew Your partner for induction heating systems for manual and automated solutions

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

Chapter 22: Electric motors and electromagnetic induction

The Do s and Don ts of Pressure Transducers

Basics of Electricity

Estimation results on the location error when using cable locator

A Practical Guide to Free Energy Devices

Precision Analog Designs Demand Good PCB Layouts. John Wu

Eðlisfræði 2, vor 2007

FEATURES AND BENEFITS OF DIFFERENT PLATINUM ALLOYS. Kris Vaithinathan and Richard Lanam Engelhard Corporation

Weld Cracking. An Excerpt from The Fabricators' and Erectors' Guide to Welded Steel Construction. The James F. Lincoln Arc Welding Foundation

INNOVATIVE ELECTROMAGNETIC SENSORS

Thermal Effects of Mobile Phones

Coupling Magnetic Signals to a SQUID Amplifier

5. Measurement of a magnetic field

Tutorial One: Calculation of leakage inductance of transformer using FEM MVA, 132 kv/33kv, Y/, Ampere-turns: , No.

Magnetic Circuits. Outline. Ampere s Law Revisited Review of Last Time: Magnetic Materials Magnetic Circuits Examples

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Heat. LD Physics Leaflets. Determining the adiabatic exponent c P /c V of various gases using the gas elastic resonance apparatus P2.5.3.

Ferroxcube. For more information on Product Status Definitions, see page Sep CBW625

PS-6.2 Explain the factors that determine potential and kinetic energy and the transformation of one to the other.

The performance improvement by ferrite loading means - increasing, - increasing of ratio, implicitly related to the input impedance.

Calculation of Temperature in a Large Turbine Generator with Multilayer Roebel Transposition Coils

7. What is the current in a circuit if 15 coulombs of electric charge move past a given point in 3 seconds? (1) 5 A (3) 18 A (2) 12 A (4) 45 A

EMI and t Layout Fundamentals for Switched-Mode Circuits

MEASUREMENT SET-UP FOR TRAPS

International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

Slide 1 / 26. Inductance by Bryan Pflueger

Transformer Calculations

Tag Tuning/RFID. Application Note. Tag Tuning. Introduction. Antenna Equivalent Circuit

Transcription:

Design and Implementation of High Frequency Inductor for Simultaneous Hardening Mohammed. Ridha. Saeed. Al- Hendaw Al- Hussain Engineering University Collage. Iraq alhussainunv@gmail.com Abstract: This paper aimed at an investigating the design principles of coil and attempt manufacturing high frequency induction heating coils which are important elements in heat treatment process and the cost of importing such coils are not readily available upon request. A number of factors taken into consideration such as, dimension configuration of work- pieces, number of parts to be heated, temperature required, pattern of heat desired, applied frequency and level of power. In this work a design of two coils of ( Ø 40 mm) and (Ø 60 mm) inner diameter. The two coils are febracted from red copper. This design improved that the greatest number of flux lines in a solenoid coil is toward the center of the coil, also prevent the cancellation of the field of magnetic coils. The results show that the designed coils are of higher resistance (50 M Ω for Ø = 40 mm and 500 M Ω for Ø = 60 mm); also the coils resistances are (0.20Ω for Ø = 40 mm and 0.22 Ω for Ø = 60 mm) Keyword: Induction coil, Heat treatment, surface hardening, casus depth, frequency. الخلاصة: هذه المقالة تتناول التحري عن اختيار القواعد الا ساسية لتصنيع ملف حث للترددات العالية والذي هو يعتبر العنصر الا ساس في ا جراء عمليات المعالجة الحرارية ومقارنة ذلك مع كلفة استيراد الملف المماثل. تم اعتماد عدد من العوامل المهمة مثل ا بعاد وشكل القطع المعالجة حراريا وعددها درجة الحرارة المطلوبة نظام المعالجة الحرارية الترددات المستخدمة ومستوى القدرة. حيث تم في هذا البحث تصميم ملفين بقطر ٤٠ ملم و ٦٠ ملم واستخدمت ا نابيب النحاس الا حمر. في هذا التصميم تم استنتاج ا ن اكبر عدد من خطوط الفيض الكهرباي ي في الملف هي باتجاه محور المركز وهي تحقق منع الفيض المغناطيسي في الملف كما ا شارت نتاي ج التصميم ا لى ا ن الملفات ذات مقاومات عالية وكما يلي 50 MΩ for 40 mm و 500MΩ for 60mm وذلك في حالة عملها. الكلمات المفتاحية: المصطلحات الواردة: تردد عمق المو ثر تصليد سطحي معالجة حرارية ملف الحث. Introduction: Introduction heating is a process used to bond, harden or soften metals or other conductive materials. For many modern manufacturing processes, induction heating offers an attractive combination of speed, consistency and control. All induction heating applied systems are developed using electromagnetic induction which was first discovered by Michael Faraday in 1831. Electromagnetic induction refers to the phenomenon by which electric current is generated in a closed circuit by the fluctuation of current in another circuit placed in the next circuit. The basic principle of induction heating has been understood and applied to manufacturing since 1920. During world war LI, the technology developed rapidly to meet urgent war time requirements for a fast, reliable process to harden engine parts. More recently, the focus on lean manufacturing techniques and emphasis on improved quality control have led to a rediscovery of induction technology, along with the development of precisely controlled, all solid state induction power supplies, [Rudnev, 2003]. The development of high frequency induction power supplies provided means of using induction heating for surface hardening. The early use of induction involved trial and error with built up personal knowledge of specific application, but a lack of understanding of the basic principles, [Rudnev, 2005].Throughout the years the understanding of the basic principles has been expanded extending currently into computer modeling of heating application and processes, [Rudnev, 2005].

Knowledge of these basic theories of induction heating helps to understand the application of induction heating as applied to induction heat treating. Induction heating occurs due to electromagnetic force fields producing an electrical current in a part. The parts heat due to the resistance to the flow of this electric current. The induction heating method is a unique due to the fact that in the most common heating methods, a torch or open flam is directly applied to the metal part. But with induction heating, heat is actually "induced" within the part itself by circulating electrical currents, [Heat Treating, 1991]. Induction heating relies on the unique characteristic of radio frequency (RF) energy that portion of the electromagnetic spectrum below infrared and microwave energy. Since heat is transferred to the product via electromagnetic waves, the part never comes into direct contact with any flame, the inductor itself does not get hot (watch video at upper right), and there is no product contamination. When properly set up, the process becomes very repeatable and controllable. Heat loss, which occurs during the induction heating process, was major headache undermining the overall functionality of a system, [Induction Heating system Topology Review Rev, 2000]. The induction heating work according to the basic understanding of the principles of electricity. When an alternating electrical current is applied to the primary of transformer, an alternating magnetic field is created. According to Faraday's Law, if the secondary current of the transformer is located within the magnetic field, an electric current will be induced. The basic of induction heating is comprised of the three factors: electromagnetic induction, the skin effect, and heat transfer. The basic induction heating setup is shown in Fig.(1).A solid state (RF) power supply sends an AC current through an inductor (often a copper coil), and the part to be heated ( the work piece) is places inside the inductor. The inductor serves as the transformer primary and the part to be heated becomes a short circuit secondary. When a metal part is placed within the inductor and enters the magnetic field, circulating eddy currents are induced within the parts. As shown in Fig.(2), the eddy currents flow against the electrical resistivity of the metal, generating precise and localized heat without any direct contact between the part and the inductor. This heating occurs with both magnetic and non magnetic parts, [lozinskii, 1969]. The main parameters affected the inducting heating are types of material, [Heat treating device and treating method Us 7648600, Jan 29, 2009, Neturen Co. Ltd], magnetic and non magnetic, thickness and resistivity, [Inductive heating converter comprising a resonant circuit with simultinance multi-frequency current, 01/2/2010].

Fig. (1): typical Induction Heating set up Fig. (2): Induction current Experimental work: The experimental work included design and development of two induction unites. The design depend on a number of parameter such as resistance, electromagnetic, induction, shin effect and power system. All metals conduct electricity, while offering resistance to the flow of this electricity. The resistance of this flow of current causes losses in power in the form of heat. This due to the law of conservation of energy, which is transformed from one to another and not lost. As shown in Fig.(2).The losses produced by resistance are based upon the basic electrical formula [P = i 2 R],where (i) is the amount of current, and (R) is the resistance. Because the amount of loss is proportional to the square of the current, doubling the current significantly increases the loss (or heat) produced. Some metals, such as silver and copper, have very low resistance and, consequently, are very good conductors. Other metals, such as steel, have high steel resistance to an electric current, so that when an electric current is passed through them, substantial heat is produced. The steel heating coil on top of an electric stove is an example of heating due to the resistance to the flow of the household, 50 Hz electric current. The higher the frequency of the current administered to the coil, the more intensive is the induced current flowing around the surface of the load. The density of the induced current diminishes when flowing closer to the center as shown in formula (1) and (2). i x = i 0 e -x/d0.(1) Where: i x = distance from the skin (surface) of the object, current density at (x) i 0 = current density on skin depth (x = 0) d 0 = a constant determined by the frequency(current penetration depth)

d 0 = (2) where p = resistivity µ = permeability of the object = frequency of the current flowing through the object. In our coils design the distribution of current density with relation to the surface thickness is shown in Fig (3). Inductor design is one of the most important aspects of the overall system. A well designed inductor provides the proper heating pattern for a part and maximizes the efficiency of the induction heating power supply, while still allowing easy insertion and removed of the part. Any surface induction heat treatment required a carefully selection of equipment and understand the metallurgical variables that control the process. The most important equipment are inductor design, generator frequency, and applied power density. Solenoid coils designed according to the following factor: * Dimensions and configuration of work piece to be heat treated. * Number of work pieces. * Temperature required. *Heat treated depth. * Applied frequency and power level. The coil must be designed to prevent cancellation of the magnetic field induction by opposite sides of the inductor. The two coils are made of pure copper material with inner diameter of Ø40 mm and Ø60 mm, and the thickness of heating ring is 1.6 mm and for cooling ring 2.1 mm as shown in Schematic diagram in Fig. (4) and Fig. (5-A-B). Fig. (3) distribution Cart of current density and skin Thickness x= mm i 0 = Amp/mm 2

Fig. (4): Schematic diagram of induction coil Ø50 mm Fig. (5-A): Induction coil Ø 60 mm

Fig. (5-B): Induction coil Ø60 mm Fig (6): (A): Ratios of object thickness, a. (B): reference depth,b. Generator frequency is determined by the material, part size and the need for through or surface heating. Low frequencies, which provided large penetration depths of the induced eddy currents, are used for through heating treating. High frequencies

are used for surface heat treating. Heating efficiency is the percentage of the energy put through the coil that is transferred to the work piece by induction. As shown in Fig (6), if the ratio of work piece diameter to reference depth for a round bar drops below about (4 to1), the heating efficiency drops. This ratio becomes as defined for round bars to be heat treated, as the critical frequency for heating. Fig (7) shows the critical frequency as a function of diameter for round bars. Fig (7) Critical temperature as a function of diameter for round bars. Power density is the power per unit of surface area. The same power input can lead to a low heating rate for a large part or a high heating rate for a small part. As with frequency, power density levels is selected based on the need for through or surface heat treating. The size of the induction power supply required for heating a particular part can be calculated. First, it's important to determine how much energy need to be transferred to the work piece (part) to be heat treated. This depends on the mass of the material being heated, the specific heat of the material, and the rise in temperature required. Heat losses from conduction, convection and radiation should also be considered. The final design of the coil and power system is shown in Fig. (8). Result and discussion: The efficiency of the two manufactured coils compared with that of imported coil, when the subjected to the following inspections before installation on the machine, these test, are carried out in Quality control laboratory. In this test many trials are carried out using both imported coil of Ø60 mm and the manufactured coil of Ø60 mm. Medium carbon steel samples (A151 1045) are used for heat treatment and the result are shown in tables (1) and (2). Table (1) Trails of imported coil Ø60 mm Samples diameter Ø mm 90 85 80 75 70 Transformer secondary voltage (v 2 ) - v 450 321 281 280 280 Current (A) 180 180 180 160 150 Case Depth (mm) 1.3 1.7 1.2 0.9 0.7 Hardness H v 792 763 763 565 454

Table (2): trials of manufactured coil Ø60 mm Samples diameter Ø mm 90 85 80 75 70 Transformer secondary voltage (v 2 ) - v 450 320 280 280 280 Current (A) 180 180 170 160 160 Case Depth (mm) 1.4 1.8 1.6 1.0 0.8 Hardness Hv 690 700 710 570 460 Fig (8): Power system and induction coil with heat treated sample. The manufacturing coils are designed according to a number of conditions such as,the coil should be coupled to the part as closely as feasible for maximum energy transfer, and the greatest number of flux lines in a solenoid coils toward the center of the coil, also the sample or part should be placed in the center of the induction coil. The manufactured coils are inspected and the result is compared with the imported coil. Insulation resistance: 250 M Ω for manufactured coil Ø = 40 mm 500 M Ω for manufacture coil Ø = 60 mm. 100 M Ω for imported coil of Ø = 60 mm. Coil resistance 0.20 Ω for manufactured coil of Ø = 40 mm. 0.22 Ω for manufactured coil of Ø = 60 mm. 0.25 Ω for imported coil of Ø = 40 mm. Also the test results of the manufactured coil with that of imported coil are shown in Fig. (9) and Fig. (10). More similarities can be seen in behavior of the relation between case depth, current and between case depth and hardness.

Fig. (9) Comparison between Imported and Manufactured Coils Fig. (10) Comparison between Imported and Manufactured Coils Conclusions: 1. Induction heating is a process which is used to bond harden or soften metals. 2. High frequency induction depends mainly on Ohm's Law. 3.Hardening depth is dependent on penetration depth (p), which is calculated through frequency (f), and as frequency increased hardening depth increases. D = 3.5p p = 4. The inductor coil is device that shapes the electromagnetic field a round and into the part or material being heated. 5. The performance of the manufactured coils is the same as that of the imported coil. 6. The court of manufactured coils is very low as compared with that imported coils. References: Heat Treating, vol.4, ASM Handbook, ASM international, 1991. Heat treating device and treating method Us 7648600, Jan 29, 2009, Neturen Co. Ltd. Induction Heating system Topology Review Rev, D, July, 2000.

Inductive Heating converter comprising a resonant circuit with simultinance multifrequency current,01/2/2010. M.G.lozinskii,1969, Industrial Applications of induction Heating, pĕrgamon press. Rudnev,V., Loveless,D., cook R.,and Black, M.,2003, Marcel Dekker,Hand book of induction heating, New York. Rudnev,V., 2005,proceedings of A514 Heat Treating Society conference Pittsburgh, Failure Analysis of induction coils, Pa, Sept. Rudnev,V.,2005, Heat Treating progress, Electromagnetic Forcesin induction Heating vol5, No. 4, July.