GA1000 oscilloscope PC Software Instruction

Similar documents
Select Correct USB Driver

The serial port is another kind of transmission mode in some outdated PC as a supplementary in failure of USB transmission.

Resolving USB Driver Problems

Configuring Windows 7 64 bit for AutoVISION

Midland BT Updater BTUpdater Program Program file (x86) ), Midland

TouchKit Software User manual for Windows 7 Version:

FreeCapture - A PC remote control program for GDS-800

EXPERIMENT NUMBER 5 BASIC OSCILLOSCOPE OPERATIONS

CLEARONE DOCUMENT (REVISION 1.0) October, with Converge Pro Units

USING WINDOWS MOVIE MAKER TO CREATE THE MOMENT BEHIND THE PHOTO STORY PART 1

Mini Amazing Box Update for Windows XP with Microsoft Service Pack 2

Centurion PLUS CPC4 Download Guide

PicoScope 6 Self-Help Guide

Dash 8Xe / Dash 8X Data Acquisition Recorder

NOTE: PLEASE DO NOT ATTEMPT TO INSTALL THE SOFTWARE BEFORE READING THIS DOCUMENT.

Instructions for the installation of drivers and data reading software (TOOLBOX 4) The simple and reliable way to measure radioactivity.

Manual for the sound card oscilloscope V1.24 C. Zeitnitz english translation by P. van Gemmeren and K. Grady

SW43W. Users Manual. FlukeView Power Quality Analyzer Software Version 3.20 onwards

AC Measurements Using the Oscilloscope and Multimeter by Mr. David Fritz

Auto Clicker Tutorial

Building a Simulink model for real-time analysis V Copyright g.tec medical engineering GmbH

Dash 18X / Dash 18 Data Acquisition Recorder

User s Guide DSO-2150 USB PC Based Digital Oscilloscope Operation Manual

PN-L702B LCD MONITOR TOUCH PANEL DRIVER OPERATION MANUAL. Version 2.1

Installing Remote Desktop Connection

User s Guide DDS-3X25 USB ARBITRARY FUNCTION GENERATOR

Professional Surveillance System User s Manual

KCU-02 Monitor. Software Installation User Manual. For Windows XP and Windows 7

Instrument Software Update Instructions. Keysight X-Series Signal Analyzers (PXA/MXA/EXA/CXA) Upgrading an older version to A.12.

Table of Contents. 1. Overview Materials Required System Requirements User Mode Installation Instructions..

KI6501 Data Manager. Software User Manual

Embest DSO2300 USB Oscilloscope

PropScope USB Oscilloscope

ZKTime5.0 Attendance Management Software User Manual

ScanWin Installation and Windows 7-64 bit operating system

BodyMedia SenseWear Retrieve (V1)

Vmed QUICKSTART PC-DISPLAY INSTALLATION & PC-Display and Bluetooth Instructions

How to install USB driver (MICRO/I)

PP8X Printer Driver Installation Instruction

SAPIP GUI INSTALLATION. Table of Contents

Thuraya XT-DUAL. Software Upgrade Manual

Multi Channel software

Celluon Laserkey - User Guide for Microsoft Windows XP

SOFTWARE INSTALLATION INSTRUCTIONS

Installation Notes for Prolific PL-2303 USB Driver for USB - RS232 Adaptor Cable 1. Uninstall Existing USB-Serial Adaptor Drivers

Communication with BushingGard using computer USB port

OPERATION MANUAL. MV-410RGB Layout Editor. Version 2.1- higher

Getting to Know Your Mobile Internet Key

TR-3 Channel Editor. Software Manual

USER S MANUAL. Hantek6022BE. V1.0.3

USB 2.0 VGA ADAPTER USER MANUAL

Numerical Parameters Analysis of Boonton 4540 Peak Power Meter

VirtualXP Users Guide

CANON FAX L360 SOFTWARE MANUAL

User Guide. VT1708A VIA HD Audio Adeck For Windows 2000, Windows XP & Server Jun Revision 1.1e

Procedure for updating Firmware of EZ4 W or ICC50 W

Kodu Curriculum: Getting Started with Keyboard and Mouse

CACI Virtual Private Network (VPN) I N F O R M A T I O N D E P L O Y E D. S O L U T I O N S A D V A N C E D. M I S S I O N S A C C O M P L I S H E D.

USB FLASH DRIVE. User s Manual. USB 2.0 Compliant. Version A Version A10

Data Analysis 1. Click the 2-Cursor icon (Figure HH-7-L1) so that two blue vertical lines appear over the recording window.

Virtual Office Remote Installation Guide

COMBOGARDPRO. 39E Electronic Combination Lock SOFTWARE INSTALLATION INSTRUCTIONS

Field Calibration Software

BIGPOND ONLINE STORAGE USER GUIDE Issue August 2005

For Windows XP 64 bit

Outlook to Windows Live Mail

QUICK START GUIDE. SG2 Client - Programming Software SG2 Series Programmable Logic Relay

Using a USB to Serial adapter and Terminal Emulator in Windows 7 to communicate with a DM101

SCU-18 PC Connection Cable Driver Installation Manual

AUDITVIEW USER INSTRUCTIONS

Lab 4 - Data Acquisition

Installing Global Logger USB Drivers

VisTablet Manual. For 12 VT Original and Mini Mouse

Quick Start Using DASYLab with your Measurement Computing USB device

SHORETEL CALL MANAGER Installation Instructions:

Citrix Client Install Instructions

DriveClone Server. Users Manual

Page 1 S5.5 Monitoring Software Manual Rev 1.2 for Software Ver 1.0

Lab 1: The Digital Oscilloscope

StrikeRisk v6.0 IEC/EN Risk Management Software Getting Started

Power Log PC Application Software

Digital Video Recorder Client and Network Manual V1.1 Table of Contents

Software Manual Virtual COM for USB Driver / Configuration Tool


FACTORY AUTOMATION MANUAL USB VIRTUAL COM PORT DRIVER INSTALLATION UNDER WINDOWS XP/WINDOWS 2000

STEELSERIES FREE MOBILE WIRELESS CONTROLLER USER GUIDE

Testo FlashUpdate. Instument Software Update and Download Instructions How to Download Instrument Software and Updates from the Internet

User s Manual. Management Software for ATS

Supplemental USB Driver Installation Guide

Transferring Scans from your Dolphin into Destiny

Schneider OS-Loader usage via Ethernet or USB.

How to install USB driver (MICRO/I)

Data Logging Software and Cable Bundle Model DL-SC3 User Manual. Overview

computer (please download the software from the official website if there is no CD available).

Connecting your Omega/BetaPAT PLUS to a PC via a USB

Work with Arduino Hardware

4 Wire / 5 Wire Resistive Touchscreen

Motorola Phone Tools. Quick Start

LCD MONITOR TOUCH PANEL DRIVER 2 OPERATION MANUAL. for Mac. Version 1.0 PN-L703A/PN-70TA3/PN-L703B/PN-70TB3/PN-L603A/PN-60TA3/PN-L603B/PN-60TB3

Installing PowerLink on Windows 7 64-bit

Transcription:

GA1000 oscilloscope PC Software Instruction 1. GAScope PC Software Overview GAScope PC software is a supplementary software of oscilloscope GA1000 series. It could be used for observing waveforms and operating oscilloscopes by computer and meets the needs of particular circumstances when operating an oscilloscope. Kindly note that this program is for Windows operating systems only. Recommended for Win XP and WIN 7 (32 & 64 bit) operating system. 2. Installation Steps 2.1 Click GAScopeSetupCn.msi icon to start the installation, as shown in Figure 2 1. Click on the "Next", choose the installation path, and then click "Next" to continue with the installation, as shown in Figure 2 2. Figure 2 1

Figure 2 2 2.2. At the end of the installation procedure a pop up window SETUPV1.40 appears, which prompts to install the USB driver files. If the computer that you are installing does not be pre installed with the USB driver, then click INSTALL to install driver; if the diver is already installed in your computer, close the window, as shown in Figure2 3. Figure 2 3 2.3. Click Close to complete the installation, as shown in Figure 2 4.

Figure2 4 If you want to uninstall, find GAScope in the Start > All programs and click on the Uninstaller. 3. Instructions for Use 3.1 Overall Interface Channel settings Waveform display Acquisition settings Trigger settings Measurement results Language selection Figure3 1 Function keys

Figure 3 1 is the overall interface of GAScope, which is divided into waveform display area, measurement result area, language selection area, etc, as shown in the red box. Waveform display area: displays waveforms of the connected oscilloscope. Measurement results area: displays 6 sets of measured values of double channels. The default values include frequency, period, vpp, amplitude, average, positive pulse width. You can change the type of measurement by clicking "Measure" button. Language selection area: selects the appropriate language pack. Channel settings area: displays or sets channel control information of the connected oscilloscope, such as vertical position, offset, coupling, and so on. Acquisition settings area: displays or sets acquisition control information of the connected oscilloscope, such as timebase and acquisition types. Trigger settings area: displays or sets trigger control information of the connected oscilloscope, such as the trigger types, trigger level and so on. Function keys area: includes connections, waveform operation, measurement, cursors and so on. Below is the detailed description of various function keys. 3.2 Connection Click "Connect" button and the connection settings interface appears, as shown in Figure 3 2. The PC software could be connected with the oscilloscopes through two ways: RS232 and USB. USB connection is recommended for his quicker speed. When using a serial port connection, PC software and the oscilloscope must set to the same baud rate, or the connection is not successful. Figure 3 2 After a successful connection, the waveform display area simultaneously displays

the waveform of the oscilloscope. The top of the display area shows "Connected" prompt message, as shown in Figure 3 3. The top of waveform display area shows the trigger information " Triged" and a rising edge icon, the right side displays trigger level Information " T. The right control area shows the main set up information of the current scope, such us vertical sensitivity, time base, acquisition types, trigger types, trigger level. You can control the settings of the oscilloscope by changing corresponding settings. Figure 3 3 To disconnect the oscilloscope from the PC click the "Connect/Disconnect" button and then display "disconnected". The connection between oscilloscope and PC will be disconnected. "Run/stop" key controls the run and stop of the waveform. The "Automatic" key automatically sets the corresponding waveform and shows the appropriate parameters. 3.3 Virtual Panel Click on the "Panel" button and a virtual panel interface appears, as shown in Figure 3 4. This virtual panel is almost the same with the panel of the oscilloscope, which is also divided into function keys area, vertical control, level control, trigger control and so on. Note that the left "MB_1" to "MB_5"are digital oscilloscope's five soft keys, which play a different role in different menu structures. This Panel can be in place of the actual panel for oscilloscope operation. Contrasted with this virtual panel, Channel, trigger, acquisition control zones in Figure 1 are shortcut control of the common functions, and they also play a role of displaying related information.

Figure 3 4 3.4 Waveform math operation Figure 3 5 is a settings interface for waveform math operation and you can set up five math operation on it. (Note: You need to set relevant parameters of FFT when you select FFT). You can choose the appropriate Proportion so as to get a better look at the entire result of the operation in the waveform display area. For example, input a 1KHz square wave into channel 1 and 2, select A+B, Proportion 1, as shown in Figure 3 6, then the red wave is the result of adding. Figure 3 5

Figure 3 6 3.5 Measurement Click" Measure" button, will pop up the "Measure" setting interface as shown in Figure 3 7. Click the dropdown button of parameters 1 6 and select the corresponding measurement type. For example, select parameter 6, change "pulse width 1" into "bottom value 1", then you can see the relevant change happen in measure results area, as shown in Figure 3 8. Figure 3 7

Figure 3 8 3.6 Cursor Click on "cursor" button and the "cursor" setting interface appears, as shown in Figure 3 9. For example, select Ch 1 and Time and get the cursor test results as shown in Figure 3 10. You can measure the value of a period by using mouse to move both cursors. At that moment, a difference value "T=1.00ms" will be shown on the top of waveform display area. Figure 3 9

Figure 3 10 This software is concise and clear. It is an assistive software of GA1000 series. More operation about the oscilloscope, please see also the user manual of GA1000 series