2808 Absence Of Water Sensor

Similar documents
INSTALLATION / OWNERS MANUAL MODEL WB-200. PN # D-01 l-0007

DeltaSpan Submersible Pressure Level Transmitter Manual LD31 Series 22 AUG 08 Rev A

InHome Water Leak Detection Package

Water Leak Detection System

P R O D U C T S P E C I F I C A T I O N MSA Ultima X Series Sensor/Transmitter Specification

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Manual for Fire Suppression & Methane Detection System

Series 510 Submersible Level Transmitters

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

Operating Instructions. UL325 Compliant Non-monitored

Duct Humidity Transmitter

with Electronic Assistant

BACK PRESSURE MONITOR Operator Display with Exhaust Temperature KIT

Temperature & Humidity SMS Alert Controller

Operating Instructions

Solid State Timers Type F

TDAS G5-DB Hardware User s Manual

DORMA MODEL PS-406BB POWER SUPPLY INSTALLATION INSTRUCTIONS

Centro-Matic Automatic Lubrication Systems System Controls

SECTION DETECTION AND ALARM

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

O C M III. Open Channel Flow Monitor

IPX AUTOMATIC IP NETWORK LOSS BACKUP A/B SWITCH INSTRUCTION BOOK IB

SDX Submersible Depth Transmitter User Manual

Global Water Instrumentation, Inc.

EDD-600 FLOW TOTALIZER RATE INDICATOR OPERATION MANUAL. P.O. Box Odessa, Texas USA.

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Introduction. Safety Guidelines. Part Numbers. Operation and Maintenance Manual. Operation and Maintenance Manual

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

2.24. Pump Controller 704. Data Sheet

RAY-MAX Integrated Solar Power Strip

INSTALLATION INSTRUCTIONS

Signal Manager Installation and Operation Manual

Wireless Home Security Alarm System AM 500

WMT-3000 Wireless Transmitter. Owner s Manual

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

DTW Works Master Specification Version 2006

OPERATING MANUAL CONTRACTOR STYLE AXIAL FANS

ATL Fuel Level Sender Probes

SMART SENSOR COLLECTION

CruzPro VAF110. AC Volts, Amps, Frequency, kw Monitor

Temperature & Humidity SMS Alert Controller

AIM TECHNICAL MANUAL PATENT PENDING STOP REMEMBER TO ACTIVATE UNIT BEFORE TESTING. See page 9 for Activation Instructions

omega.com ΩOMEGA RS232 Multi-Drop FMA1600-MDB Multi-Drop Box

FIREDEX Conventional Fire Panels

CENTERLINE Motor Control Centers Bulletin 2100 Smoke Detector Unit

FIRERAY 2000 Installation Guide

Fiber Optics and Liquid Level Sensors Line Guide

Installation and Operation Manual. Digital Remote Meter for Monitoring System Performance. Version: RM-1

SPECIAL NOTICE. All references to NAT product part numbers (and associated images) are equivalent to AEM product part numbers.

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

AUTODIALLER / QUICKDIALLER - SA132

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Operating Instructions

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

CalMod Design-Build Electrification Services

Inductive Proximity Sensors

Programming Logic controllers

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

USER GUIDE. Studio Hotline Multi-line System Phone Flasher and Door/Alert Indicator Input Module and Indicator. DM Engineering. Version 1.

Installation guide H A. HSI hardwired system interface

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Solar Power Systems Models: PVS220W-24 and PVS220W-48 Installation Manual

CONTENTS. PAGE Chapter 1 General Information 1. Chapter 2 Setup 4 DP450-VDC 7 DP450-VAC 7 DP450-DCC 7 DP450-F 8 DP450-HACC 9 DP450-HDCC 11 DP450-E 13

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels

4-Wire Air Duct Smoke Detector. Protection Systems. A UTC Fire & Security Company. Models DH-60 FEATURES APPLICATION DESCRIPTION SAMPLING TUBES

12V Dimmable Driver EL-TMDRVR

User Manual for CH-PFC76810

HAM841K ALARM CONTROL PANEL FOR COMMERCIAL AND RESIDENTIAL SECURITY SYSTEMS

Owner's Manual [ S/N LABEL HERE ] Document # BW-BCU5DOC

SC100 Series Seismic Vibration Sensors. The Best Way to Protect High-Risk Commercial Assets

Troubleshooting accelerometer installations

IEI 232e Standalone TM Keypad Installation/ Programming Manual

PASSIVE INFRARED INTRUSION DETECTOR PASSIVE INFRAROOD DETECTOR DETECTEUR D INTRUSION PASSIF INFRAROUGE

Global Water Instrumentation, Inc.

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

POINTS POSITION INDICATOR PPI4

Technical Note Series

INTRUSION DETECTION SYSTEM Section

Transformer-coupled passive transmit path with a fixed insertion loss of approximately 1.0dB.

Recommended Tools and Supplies: Small Flat Blade Screwdriver, 35mm x 7.5mm DIN Rail. Qwik Install

Specifications for EM VDC 4 In/4 Out and EM VDC 4 In/4 Relay Out

User's Guide. Integrating Sound Level Datalogger. Model Introduction

STEALTH I DC MANUAL TECH SUPPORT WEB BLACK UNIT IS 24/36 ONLY

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

OPERATING INSTRUCTIONS

DIGITAL ALARM II FOR HOSPITALS AND LABORATORIES INSTALLATION AND OPERATING INSTRUCTIONS

PART 1 - INTRODUCTION...

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

SEMICONDUCTOR TECHNICAL DATA

Sample specifications for an effective Flow Monitoring Services RFP

tidesmarine Smart Seal Temperature Alarm System Generation II Installation Instructions Starboard side cable

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Home Security Alarm System

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

1/2 NPTM mm Nose cone fitting Ideal for clean liquids

CHAPTER 1. GETTING STARTED... 1

KCIEN KCIENSBP. Heavy Duty Stainless Steel Illuminated Keypads INSTALLATION MANUAL. Range: DIGICODE (Stand-Alone Keypad)

SECTION OPTICAL FIBER CABLES AND ACCESSORIES. A. Interior Raceways, Fittings, and Accessories: Section

Automatic Phone-Out Home Monitoring Systems

Transcription:

Home Products About GRI Contact GRI Where to Buy Testimonials What's New! Absence Of Water Sensor Microprocessor Controlled Detects Absence or Presence of Liquid Powered by 5 Year Lithium Battery Standard Sample Rate is Once Every 2.5 Minutes Form C Relay Absence of Water Sensor The GRI Absence of Water Sensor is a totally new innovative design that helps monitor the level of water and other non flammable liquids. The GRI is submersible, fully self-contained and responds reliably to the absence of or the presence of water. The GRI fits a multitude of applications in a wide range of environmental landscapes. The GRI microprocessor conducts a sample every 2.5 minutes. Optional custom sample rates are available. Call the factory for more information. The C-form relay gives the installer greater flexibility for triggering wireless and hardwired communication devices.

ABSENCE OF WATER DETECTOR Series! Senses The Lack Of Or Presence Of Any Non-Volatile Liquid! Microprocessor Controlled! Submersible and Fully Self Contained! 12 Cable GEORGE RISK INDUSTRIES, INC. G.R.I. PLAZA KIMBALL, NE 69145 The G.R.I. Absence of Water Detector is targeted for monitoring a fluid level height. This submersible sensor can safely and reliably sense and respond to the absence of or presence of a non-volatile liquid in a wide range of environmental conditions. The G.R.I. Series of Water Detectors are microprocessor controlled devices that produce an AC Signal between two stainless steel probes. Depending on the conductivity measured between the two probes, a set of internal relay contacts will be latched in an open or closed position. Sensor life span is optimized by periodically sampling for liquid at set timed intervals. Conductivity sampling between the two probes once every 2.5 minutes are used in the Standard Self Powered allowing for a 4-year expectancy. A sampling rate of once every 30 seconds is used with the Externally Powered -12V providing a 15+ year life expectancy. Instantaneous triggering and custom sampling rates are also available on request. External connections are made through the included 12 inches of Direct Burial cable allowing for up to a foot of total submersion, burial or harsh environmental exposure. Custom cable length are also available on request. Self Powered/2.5 minute sample rate/c form relay output -12V External 12VDC/30 Second Sample Rate/C form relay output Warranty: One year warranty against workmanship, material and factory defects. TOLL-FREE 1-800-445-5218 MADE IN U.S.A. TOLL-FREE 1-800-523-1227 (308) 235-4645 FAX (308) 235-3561 E-MAIL: sales@grisk.com WEB SITE: www.grisk.com

ABSENCE OF WATER DETECTOR INSTALLING THE G.R.I. : The G.R.I. Absence of Water Detector is installed by mounting the unit so that sensor probes are located at the desired fluid level position. Insertion of the into the liquid will confirm that mounting point as the minimum liquid level height. Mounting the above and out of the liquid will confirm that mounting point as the maxi- mum liquid level height. The latching C form relay output will set upon first initial sampling after mounting, and maintain that set during subsequent samplings up to and until a change in status occurs. At that time, the C form relay will reset, signalling that change. The device is secured in place using the provided plastic strap. Connections to the relay contact wires are made using a suitable wire connector. Note: Watertight connectors may be needed if connector location will be submerged. These detectors should be inspected and tested annually. If there is damage the detector should be replaced. 12VDC Ground -12V Wiring Diagram GEORGE RISK INDUSTRIES, INC. G.R.I. PLAZA KIMBALL, NE 69145 BA-185 Rev. G 6/24/2015-12V Only Operating Voltage 9 volts DC - 28 Volts DC Operating Current 7 ma nominal and -12V Operating Temperature: 70º C to -40 C MADE IN U.S.A. TOLL-FREE 1-800-445-5218 TOLL-FREE 1-800-523-1227 (308) 235-4645 FAX (308) 235-3561 E-MAIL: sales@grisk.com WEB SITE: www.grisk.com

PRODUCT DESCRIPTION FOR THE ABSENCE OF WATER DETECTOR GRI APPLICATION: The G.R.I. Absence of Water Detector is targeted for monitoring a fluid level height. This submersible fully selfcontained sensor can safely and reliably sense and respond to the absence of, or the presence of a non-volatile liquid in a wide range of environmental conditions. DESCRIPTION: The G.R.I. Absence of Water Detector is a microprocessor-controlled device. The sensor produces a one second signal between two stainless steel probes once every 2.5 minutes. Depending on the conductivity measured between the two probes, a set of internal relay contacts will be latched in an open or closed position. External wire connections are provided for control interface. Connection to a communication device such as a wireless transmitter or a signal processor will allow the to be used as a set and forget it liquid sensor. INSTALLATION INSTRUCTIONS INSTALLING THE G.R.I. : The G.R.I. Absence of Water Detector is installed by mounting the unit so that sensor probes are located at the desired fluid level position. Insertion of the into the liquid will confirm that mounting point as the minimum liquid level height. Mounting the above and out of the liquid will confirm that mounting point as the maximum liquid level height. With a sampling rate set at once every 2.5 minutes a latching C form relay output will set upon first initial sampling after mounting, and maintain that set during subsequent samplings, up to PRODUCT DESCRIPTION FOR THE ABSENCE OF WATER DETECTOR GRI APPLICATION: The G.R.I. Absence of Water Detector is targeted for monitoring a fluid level height. This submersible fully selfcontained sensor can safely and reliably sense and respond to the absence of, or the presence of a non-volatile liquid in a wide range of environmental conditions. DESCRIPTION: The G.R.I. Absence of Water Detector is a microprocessor-controlled device. The sensor produces a one second signal between two stainless steel probes once every 2.5 minutes. Depending on the conductivity measured between the two probes, a set of internal relay contacts will be latched in an open or closed position. External wire connections are provided for control interface. Connection to a communication device such as a wireless transmitter or a signal processor will allow the to be used as a set and forget it liquid sensor. INSTALLATION INSTRUCTIONS INSTALLING THE G.R.I. : The G.R.I. Absence of Water Detector is installed by mounting the unit so that sensor probes are located at the desired fluid level position. Insertion of the into the liquid will confirm that mounting point as the minimum liquid level height. Mounting the above and out of the liquid will confirm that mounting point as the maximum liquid level height. With a sampling rate set at once every 2.5 minutes a latching C form relay output will set upon first initial sampling after mounting, and maintain that set during subsequent samplings, up to

and until a change in status occurs. At that time, the C form relay will reset, signaling that change. The device is secured in place using the provided plastic strap. Connections to the relay control wires are made using a suitable wire connector. Note: Watertight connectors may be needed if connector location will be submerged. These detectors should be inspected and tested annually. If there is any damage the detector should be replaced. and until a change in status occurs. At that time, the C form relay will reset, signaling that change. The device is secured in place using the provided plastic strap. Connections to the relay control wires are made using a suitable wire connector. Note: Watertight connectors may be needed if connector location will be submerged. These detectors should be inspected and tested annually. If there is any damage the detector should be replaced. Operating Temperature: 0º C - 70º C Sample Rate: 24 Per Hour (Once Every 2.5 Minutes) Operating Temperature: 0º C - 70º C Sample Rate: 24 Per Hour (Once Every 2.5 Minutes) 7/12/2007 7/12/2007