Duct Construction and Design. Mark Terzigni SMACNA

Similar documents
Welcome. Green HVAC Ductwork Done Right! John Reints, PE Eugene Smithart, PE

VariTrane Duct Designer An in depth look...

HVAC Air Duct Leakage. November 2013 Presented By: Mark Terzigni Project Manager Technical Services SMACNA

Acoustical Design Guidelines for HVAC Systems in Schools

Duct Design. Presented by Dave Janquart

FUNDAMENTALS OF ACOUSTICS

Noise in the Classroom

Case Studies Illustrating Acoustic Design Guidelines for HVAC Systems in Schools

Air-side Systems: Air Duct Design

Basic Selection & Proper Application of Overhead Air Distribution Devices

Fan Performance By: Mark Stevens AMCA International Deputy Executive Director Technical Affairs

HVAC - How to Size and Design Ducts

Design Information. Designing Your Dust Collection System. Typical dust or fume collection system

product application guide

Design Calculation or Analysis Cover Sheet. Complete only applicable items M8C-VCTO B

UNIVERSITY OF MISSOURI Heating Ventilating and Air-Conditioning (HVAC) March

HVAC Calculations and Duct Sizing

EFFICIENT DUCT SYSTEM DESIGN

FIRE DAMPER APPLICATION GUIDE

INSTRUCTIONS FOR HOW TO PROPERLY SELECT A FAN OR BLOWER

ENGINEERING DATA. Fan Performance Troubleshooting Guide

Innovent LASER Packaged Fresh Air Conditioning Units

Fundamentals of Acoustics & Practical HVAC Design Considerations. Demir Doken Acoustic Engineer

Duct Leakage Testing. Ken Helfers, TSI Inc. 2011, TSI Incorporated

Fan Applications & System Guide

SECTION EG. Engineering Guide Air Distribution. Please refer to the Price Engineer s HVAC Handbook for more information on Air Distribution.

Ventilation Solutions Kitchens. fantech

Fans and Air Handling Units. Will Rea and Paul Pilutti February 16 th, 2011

Below are detailed instructions for using the EMS load calculator.

Exhaust Calculation Booklet

Centrifugal Fans and Pumps are sized to meet the maximum

MULTIZONE APPLICATION OF SOLUTION UNITS

ANSI/AHRI Standard 880 (I-P) with Addendum Standard for Performance Rating of Air Terminals

plenum slot diffusers

Demand Based Static Pressure Reset Control for Laboratories

AABC Specifications for Testing and Balancing HVAC Systems

Relationship between Sound Pressure and Sound Power Levels

DUCT SYSTEM DESIGN CONSIDERATIONS Part 1

HVAC SYSTEMS ACOUSTICAL, COST & ENERGY STUDY

HVAC Duct Construction. Bob Wasilewski Project Manager, Technical Resources SMACNA

Mechanical Heating Ventilation and Air Conditioning Ductwork and Duct Accessories

NEBB STANDARDS SECTION-8 AIR SYSTEM TAB PROCEDURES

SECTION TESTING, ADJUSTING, AND BALANCING FOR HVAC INTRODUCTORY INFORMATION

SECTION AIR INLETS AND OUTLETS

HVAC Ducting - Principles and Fundamentals

SAM HOUSTON STATE UNIVERSITY

DRYER VENTING SPECIFICATIONS DRYER SAFETY

Balancing of a water and air system

FAN PROTECTION AGAINST STALLING PHENOMENON

Top Ten Reasons Building HVAC Systems Do Not Perform as Intended

IDES-EDU. Educational Package Ventilation. Lecture 8: Sizing mechanical ventilation systems IEE/09/631/SI

VAV Laboratory Room Airflow The Lowdown on Turndown

SECTION HVAC AIR DISTRIBUTION

Element D Services Heating, Ventilating, and Air Conditioning

ENHANCED LABORATORY HVAC SYSTEM

Building Performance Solutions HVAC Design Guide, 2007

Air Conditioning Clinic

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

Acoustic Design Guide. NR and NC Curves CIBSE Noise Ratings Environmental Noise Control Maximum Air Velocities in Ducts Privacy in Cellular Offices

DESIGN AND INSTALLATION OF RESIDENTIAL FLEXIBLE DUCTWORK SYSTEMS

NADCA White Paper: Restoring Energy Efficiency Through HVAC Air Distribution System Cleaning

Characteristics of Evaporators

Central Plant Air Systems: Keeping the Heart and. Title Style. Better Buildings Summit May 2016

Residential Duct Systems for New and Retrofit Homes

security products metric sizes Redefine your comfort zone.

Type 1 dryers: Domestic dryers to be used primarily in a family living environment. Residences Individual apartments or condominiums

HVAC Code Requirements

Methods for Effective Room Air Distribution. Dan Int-Hout Chief Engineer, Krueger Richardson, Texas

AMD-33 Air Measuring Station with VCD-33 Control Damper

3.0 Exhaust Muffler Design Principles. 3.1 Basic Concepts

Ventilation Solutions Radon Mitigation

AIR DISTRIBUTION ENGINEERING

Operation and Installation Manual. Max Series

FAN ENGINEERING. ( ) ρ N. Fan Performance Troubleshooting Guide

How To Install A Perfect 16 Id Series Filter System

HVAC Checklist - Long Form

Components HVAC General Standards HVAC Guidelines HVAC System Selection Life Cycle Cost Analysis

Basics of HVAC Cleaning

ENGINEERING DATA. Fan Sound & Sound Ratings

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

FINAL December 2012 SECTION DUCTWORK

HVAC Systems: Overview

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

Technical Information

Pool Dehumidification Basics

Minor losses include head losses through/past hydrants, couplers, valves,

Comparing Energy Savings of Different VAV Systems

HVAC Air Duct Leakage. Eli P. Howard, III Group Director Technical Resources SMACNA

WORKSHEET FOR RESIDENTIAL AIR SYSTEM DESIGN page 1

Noise Control Solutions For Standby Power Generators

ICQ Series - square centrifugal

DSRQ - DSRSQ - DSRSQ-THERM

vav retrofit terminals

CURTAIN TYPE FIRE DAMPERS

SECTION MORTUARY REFRIGERATORS

Power and Cooling for Ultra-High Density Racks and Blade Servers

Impacts of Static Pressure Set Level on the HVAC Energy Consumption and Indoor Conditions

Case Studies: Infrared Heating in Industrial Applications

HIGH EFFICIENCY RTU. HIGH EFFICIENCY, PACKAGED SPACE CONDITIONING. DX System IEER> 13.2 Gas Heat Efficiency > 92% Capacities Tons

Transcription:

Duct Construction and Design Mark Terzigni SMACNA

Design Methods There are 3 typical methods used for designing non-residential duct systems Equal Friction Static Regain Constant Velocity (exhaust and industrial)

Equal Friction Designed so each path has the same resistance Typically based on duct sized at 0.8 in wg/100ft Works for supply and return Most versatile option Can be done manually Design wheel

Static Regain Similar to equal friction Recovery in static pressure total pressure loss Supply systems only Works best on medium to high pressure systems (upstream of VAV) Best done using software (iterative process)

Constant Velocity Design to maintain a minimum velocity Used for material handling/conveying Fitting choices extremely important Use wyes not tees (30 to 60 ) Never use crosses

Fittings Fittings are where the majority of pressure losses occur. Selecting the proper fittings in the proper places can have a significant impact on energy use, and even cost. Critical path

Fittings To vane or not to vane Often specifications require the use of turning vanes in all mitered elbows This is ok but on elbows at low velocity, or not on the critical path this could be wasting money without adding benefit Specifications should indicate the number of splitter vanes required (if required) these are not turning vanes.

Pressure Loss To evaluate the pressure lost (used) as air moves through a fitting you should first determine the velocity pressure V P V P = V 4005 2 V P (in. w.g.) which is a square function of V V (fpm)

Elbow Comparison

Example Scenario As designed the plans indicate that a 24 x 12 radiused elbow (r/w=1.5) be used. Because of field conditions that radiused elbow will not fit. The contractor is faced with finding an acceptable alternative that fits The designer wants to know what the impact of changing the elbow has on the system

Example Scenario It is fairly common for contractors to simply find an elbow that fits. Because of job schedule they are often reluctant to send an RFI about these kinds of situations. Many times specifications are written to force a particular type of elbow to be used.

Fitting Comparison Velocity (fpm) 2000 4000 Elbow C ΔP (in. w.g.) ΔP (in. w.g.) radiused throat heel, r/w=1.5 0.2 0.05 0.20 square throat rad heel 1.38 0.34 1.38 mitered no vanes 1.27 0.32 1.27 mitered vanes (single @ 3.25) 0.33 0.08 0.33 radiused throat heel, r/w=1.0 0.25 0.06 0.25 mitered vanes (single @ 1.5) 0.11 0.03 0.11

Low Velocity Velocity (fpm) 800 1000 1200 Elbow C ΔP (in. w.g.) ΔP (in. w.g.) ΔP (in. w.g.) radiused throat heel, r/w=1.5 0.2 0.01 0.01 0.02 square throat rad heel 1.38 0.06 0.09 0.12 mitered no vanes 1.27 0.05 0.08 0.11 mitered vanes (single @ 3.25) 0.33 0.01 0.02 0.03 radiused throat heel, r/w=1.0 0.25 0.01 0.02 0.02 mitered vanes (single @ 1.5) 0.11 0.00 0.01 0.01

Duct Design Basics One often misunderstood idea is the critical leg or critical path. All other paths are over pressurized by design Unless all paths are the same (great but not likely) The point is that fittings used in the non critical paths will not impact the energy required for the system unless, by using the fitting, the critical path changes.

Fittings and layout changes will not impact the fan unless they impact the critical path Duct Design Basics

Duct Design Basics Changing a fitting or layout can result in changing the critical path

Duct The reality is that pressure drops are fairly insignificant in the straight sections of duct However there are some good guidelines to follow There are some misconceptions as well

Duct Round duct should be the basis of design Systems should be designed in round and then converted where necessary For non-round duct keep the aspect ratio as close to 1:1 as possible This impacts cost and pressure drops (energy)

Convert Duct Shapes There are a number of reasons that duct shape is converted Coordination Primary design is often based on round duct Cost factors Availability

Misconceptions For a given footprint round duct has less resistance (pressure drop) than square duct. Is this true? Let s do an example calculation 1600 CFM, compare 12 inch round to 12 x 12 rectangular

Misconceptions First convert the rectangular to the equivalent round (SMACNA Duct Design or ASHRAE handbook) 0.625 D 1.3( ab) = e 0.250 ( a + b) 12 x 12 rectangular = 13.1 inch round Please note that equivalent area is not a correct way to convert

Misconceptions Velocity for the round duct V=Q/A = 1600/.785 (ft 3 /min, ft 2 ) = 2037 fpm Velocity for square duct V=Q/A = 1600/1 (ft3/min, ft2) = 1600 fpm

Misconceptions Pressure drop for 100 feet of 12 inch round @ 1600 CFM ~ 0.5 Pressure drop for 100 feet of 12 x 12 inch rectangular @ 1600 CFM ~ 0.3 in. w.g. That s almost 40% less friction

Misconceptions What about flat oval? D e = 1.55AR P 0.250 0.625 Oval 24 x 12 in. ~ 17.7 in. round Rectangular 24 x 12 in. ~ 18.3 in. round

Misconceptions Velocity in the Oval @ 1600 CFM V=Q/A = 1600/1.79 = 896 FPM Velocity in Rectangular V=Q/A = 1600/2 = 800 FPM Pressure drop for 100 feet Oval ~0.066 Rect ~0.057 14% less friction -but actually insignificant

System Effect Field measurements of fan performance often indicate lower values than manufacture's ratings. Are the manufacturer s lying? No. Three main causes to lower field values Improper outlet conditions Non-uniform inlet flow Swirl at the fan inlet

System Effect Outlet Conditions Fans for ducted systems, tested to AMCA 210 or ASHRAE 51, have outlet duct in place For 100% recovery use 100% effective length

System Effect Effective Length Depends on velocity If V<=2500 fpm Ao L e = 4.3 If V>2500 fpm L = e V o A o 10,600

System Effect Using 60 x 30 inch duct @ 30,000 CFM V=2400 fpm Le = 10 ft. @ 50,000 CFM V=4000 fpm Le = 16 ft. Using 60 x 50 inch duct @30,000 CFM V=1440 fpm Le=12.7 ft. @ 50,000 CFM V=2400 fpm Le= 13 ft.

System Effect Non-uniform inlet flow Major impact on fan performance Creates a new fan curve Use inlet duct 3 to 8 diameters Depends on velocity but losses without any inlet duct can add 3.5 inches of pressure loss

System Effect Inlet conditions Abrupt inlets actually reduce the effective inlet area because of vena contracta effect

System Effect If duct isn t used try using a bellmouth or other smooth inlet Ideal uses a smooth inlet with straight section of duct A good option at least provides a smooth transition into the fan

System Effect Inlet boxes are not ideal but will reduce system effect Avoid

System Effect Swirl In the direction of the impeller reduces the pressure/volume curve Opposite the direction of the impeller actually increases the pressure/volume curve slightly but greatly increases the power consumed

System Effect To address swirl you can increase the inlet duct length, or use vanes to correct the spin

System Effect The best way to eliminate or reduce system effect is to provide space. The better the inlet and outlet conditions the better the fan will perform. Even providing duct lengths of 25% of the ideal length can result in 80% gains, 50% lengths show up to 90% gains Leave room for expansion, as equipment becomes more efficient it typically increases in size

System Effect Adequate space not provided Less than ideal inlet and outlet conditions Detailed discussion on System effect can be found in Chapter 6 of SMACNA s Duct Design Guide

Insulation Most codes require some of the ductwork to be insulated. Insulation reduces the effects of heat gain/loss as the duct moves conditioned air. Internal liners can provide thermal resistance Be careful about through metal Consult the manufacturer s data for performance, make sure to use installed values

Insulation 75 of 24 round duct @ 6,500 CFM V = 2070 fpm Desired outlet temp 120 F Air temp where duct run is located 65 The temp required at the start of the duct 123 F The heat loss is 26,000 Btu/hour 7,643 watts (76-100 watt light bulbs)

Insulation 75 of 24 round duct @ 6,500 CFM with R6 (2 inches of insulation) V = 2070 fpm Desired outlet temp 120 F Air temp where duct run is located 65 The temp required at the start of the duct 121 F The heat loss is 5,800 Btu/hour 1,700 watts (17-100 watt light bulbs) 78% reduction in heat loss

Insulation Remember to account for the weight of insulation when specifying duct construction 1 in. w.g. = 5.2 lbs./ft 2 Duct liner provides thermal benefit, main purpose is sound attenuation Be careful of through metal (condensation)

Acoustics If it is good for airflow it is usually good for acoustics. Three components: Source Path Receiver

Acoustics

Acoustics

Easy Math Acoustics

Acoustics Weighting Human ear is less sensitive to low and high frequencies More sensitive to mid-frequencies

Acoustics A-Weighting NC Usually used for outdoor sound calculations Sound is fitted to a curve Based on 8 frequencies Does not evaluate the overall shape of the curve Most used method NC-35 63 Hz 8K Hz

Acoustics ROOM CRITERIA Mark II (RC) Evaluates the shape Currently ASHRAE S preferred method Addresses lower frequencies R rumble H hiss N neutral Data not always available for products

Acoustics Start with quiet equipment Locate air-handling equipment in less sensitive areas Allow for proper fan outlet conditions Rectangular length 1.5 x largest dimension Round length 1.5 x diameter system effect

Acoustics Use radiused elbows where possible Larger ductwork reduces velocity and reduces generated noise Avoid abrupt changes in layout Place dampers away from outlets Flexible connections to equipment

Acoustics Power splits Ratio of areas L1 = 10 log (A1 (A1 + A2)) L2 = 10 log (A2 (A1 + A2)) Units db Applies across all frequencies Straight subtraction

Power Split

Acoustics Low Frequency Noise Breakout Break in Rectangular Where breakout noise is beneficial Do not use where break in noise is a concern Round Does not allow as much breakout Does not allow as much break in Thicker liner attenuates lower frequencies More mass better at attenuating lower frequencies

Acoustics Medium-High frequency Easier to attenuate than low Lined or double walled duct Lengthen runs if necessary Silencers

Acoustics Silencers Can be very effective at attenuating sound Insertion loss Pressure drops Generated noise Elbow Locate in the wall or as close as possible Do not locate right off of a fan

Acoustics Reactive silencers Low to no pressure drops Dissipative No fill use baffles and chambers

Air Tightness/Leakage Duct Leakage Accessory Leakage Equipment Leakage

Air Tightness/Leakage Duct Leakage As the term should imply is the leakage of air from the duct Accessory Leakage Leakage of air from accessories (dampers, access doors) Equipment Leakage Leakage of air from equipment (AHU, VAV) System Leakage is the combination of the above

Air Tightness/Leakage Cost for air leaks - It is difficult to put an exact cost on leakage because it depends on energy costs, where the leak occurs, environmental conditions, even altitude. It is safe to say that leakage does not provide a benefit and should be reduced as appropriate for the application

Air Tightness/Leakage Avoid arbitrary % to design as pass fail for duct tests. It is perfectly acceptable to design with a % of leakage, but this should be converted to a leakage class for duct field tests. Using a leakage class provides a way to determine pass/fail for portions of duct and at different pressures

Air Tightness/Leakage If you end up with leakage classes below 3 you are not asking for good duct you are asking for high performance duct which will likely have a cost impact. Contractors not aware of this requirement are likely to have difficulty passing a leakage test with these lower leakage rates Make sure to provide allowance for accessories if they are included in the test

Misconceptions Leakage tests provide the actual leakage rate under operating conditions Not true, traditional tests would typically provide rates that are higher than actual leakage under operating conditions because the leakage is measured at a higher pressure than operating pressure.

Misconceptions Values for low leakage dampers should provide better performance for leakage tests This depends on what kind of leakage is being referenced Most damper leakage rates refer to the leakage across the blade(s) when the damper is closed These values do not represent sleeve leakage which is the leakage of air from inside the system to outside the system

Recommendations Require that all duct be sealed to Seal Class A Be careful not to create a pass/fail so low that meeting it would require voiding listings or warranties leakage class is best for duct Test some portion of the duct 10 20-100 Focus on critical areas Test early in the process

Summary Provide proper inlet and outlet conditions for the fan Space in the mechanical room Use a duct layout that is efficient (direct) with as few fittings as possible Fitting choices are important in the critical path. Other paths are not so critical Specify seal class A for ducts and fittings Insulate

Tools SMACNA apps http://www.smacna.org/technical/index.cfm?fuse action=apps Leakage Duct construction Fitting Losses SMACNA Duct Design Manual ASHRAE ~$160 App Store ($9.99)

THANK YOU Questions?