T-MAX Parameter Setting Guide for single 3-A timers and 3-A remote timer systems.

Similar documents
T-Max Manager/Pro and T-Max 3A User s Guide Page i. T-Max Manager/Pro and T-Max 3A User s Guide Page ii

Installing Your Vonage Device in Front of an Existing Router for customers with DSL INTERNET SERVICE

Technical Guide for Installation and Maintenance

Dock-N-Talk U S E R S G U I D E. Forming a New World of Communication. SM

Vista. Vista 150 User Guide

Rev E October 2004 ZZZ*(6HFXULW\FRP. Part No: R. CareGard. User Guide

Upgrade Instructions. View Manager 96 v Software Upgrade

Quick Start. PowerLINE WiFi 1000 Models PL1000 and PLW1000

Aastra 480i Broadsoft SIP VoIP Telephone User s Guide

Installation Guide (No Router)

Installation. Powerline 500 Model XAVB5221

2.4 GHz Dual Handset Cordless Telephone Answering System 2255 with Caller ID/Call Waiting

The following is a set of definitions used in FAQs for the Partner product line:

AT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974

T7400. Guest Paging System. Long Range Systems, Inc Chartwell Dr., Dallas, TX V6.21 and later

Quick Start Guide. Vonage VWR Device

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

3NNet KVM CP-104S /OSD / 19 KVM CP-108S / OSD / 19 KVM CP-116S / OSD / 19

COLLEGE OF MEDICINE. Sony Portable Video Conference Systems. Operations Manual

Medical Alarm Unit. Instruction Manual. TEST Your Medical Button Weekly. Traditional Installation USING BASIC LANDLINE

CONNECTING PHONES, FAXS & DEVICES TO TALKSWITCH

Wireless Genie Mini MODEL C41W

Four-Line Small Business System Speakerphone 945

Blue Point Engineering

ST815 Illumination Sensor with LCD

Personal Assistance System Owner's Guide

Optional Lab: Install, Configure, and Partition a Second Hard Drive in Windows Vista

QTRONIX Programmer Pad

Meridian 8314 Business Terminal User Guide

Quick start: Energy Switch EU

TelNet Digital Fax. Reference Guide..

SMART Board Troubleshooting

ReSound Unite TV FREQUENTLY ASKED QUESTIONS. Setup & Configuration. Use & Operation. Troubleshooting

Schlage Control Smart Locks

Printed in China. Issue 1.2 AT&T 03/07. Advanced American Telephones. AT&T and the AT&T logo are trademarks of AT&T Knowledge Ventures, licensed to

Quick Start Guide. Vonage Device Motorola VT2142

HP Advanced Wireless Docking Station. User Guide

ITC-BTTN Cellular Bluetooth Gateway. Owner s Manual 1

MIGRATION HEIGHT-ADJUSTABLE DESKS. Troubleshooting Guide

Time Warner Cable Home Phone. Easy Connect Guide. Better conversations begin with better Home Phone.

CISCO IP PHONE MODEL 7960 & UNITY VOIC . Getting Started Manual

AC1200 WiFi Range Extender

CS55H HOME EDITION... WIRELESS HEADSET SYSTEM

N300 WiFi Range Extender WN2000RPT User Manual

VMB070 QUICK START GUIDE

Four-Line Intercom Speakerphone 944

Supervised Security System

How To Program An Autodialer

User Installation Guide

Enterphone Solo. User/Installation Manual Part No

AT&T Consumer Services AT&T Voic Manager 200 User s Guide

2013 Brother International Corporation (Canada) Ltd. 1, rue Hôtel de Ville, Dollarddes-Ormeaux,

TL-PA411 AV500 Powerline Adapter

ADA COMPLIANT BOX STYLE TELEPHONE INSTALLATION, PROGRAMMING AND OPERATING INSTRUCTIONS FOR MODEL PBX

Welcome to life on. Get started with this easy Self-Installation Guide.

1-Port Wireless USB 2.0 Print Server Model # APSUSB201W. Quick Installation Guide. Ver. 2A

USER GUIDE. Cisco Small Business Pro. SPA 500 Series IP Phones Models 504G, 508G, and 509G. Provided by

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Turn on all of your network devices and then check to see if the LEDs on the Access Point display normally as the diagram below describes.

USER GUIDE CS50/55... WIRELESS OFFICE HEADSET SYSTEM

AP6511 First Time Configuration Procedure

TE100-P21/TEW-P21G Windows 7 Installation Instruction

You may refer the Quick Installation Guide in the package box for more information.

istar User Manual for Comsol USB Flash Drive

User s manual. w w w. v t e c h p h o n e s. c o m. Models: mi6885/mi6889/mi6890

510 / 511 Cardiorespiratory Monitor Preventative Maintenance Test Procedure

DPH-50U VoIP USB Phone Adapter Quick User Guide

Troubleshoot your ADSL Router/Modem Setup

Personal USB VoIP Gateway User s Guide

ON HOLD ANNOUNCER. Once you receive your audio announcer, check the packaging to ensure that all of the following items are enclosed:

V.I.P. Kit. Video Insight Pilot Kit. (Video Insight Pilot Kit).

If you are unable to set up your Linksys Router by using one of the above options, use the steps below to manually configure your router.

-Helping to make your life betterwww.person-to-person.net

élan Mira WiFi Wireless Communication User Guide

Hardware Overview. Ooma Linx devices These are installed around the office and are used to connect phones and other devices to your Ooma Office system

G.A.L. HANDS FREE EMERGENCY TELEPHONE MODEL GAL-6400

Cisco Model SPA 303 Quick Start Guide

Ericsson W25. Mobile Networks. Quick Installation Guide

Apple AirPort Extreme (ME918ZP/A) Router Guide (MAC OS version)

User Guide. F912 Rev

Setup Guide. CapTel 840i /13. Catch every word with CapTel from Access Comm

WIRELESS INTERNET TROUBLESHOOTING GUIDE Help Desk

User Guide. Linksys PLWK400. Powerline AV Wireless Network Extender Kit

CM500 High Speed Cable Modem User Manual

Four-Line Small Business System Speakerphone 945

Home Network. Installation Instructions

To use your Brother machine in an ad hoc network, complete the steps listed below:

Part 2. Copyright 1998 Philips Consumer Communications L.P. All rights reserved. Printed in Mexico. Issue 1AT&T

Enterprise Edge M7310 Quick Reference Guide

AT&T Small Business System Speakerphone with Intercom and Caller ID/Call Waiting 974

PEBBLE USER MANUAL. MODEL: GMR1888DAB DAB Digital & FM Radio. Hyper-link ALL text to corresponding sections

AC750 WiF Range Extender

PRODUCTIVITY THROUGH INNOVATION 600 CONTROL DIRECT DRIVE TECHNICAL/OPERATION MANUAL

To perform Ethernet setup and communication verification, first perform RS232 setup and communication verification:

1. Power Light: indicates whether AC power is available to the unit. 2. DS (Downstream): indicates downstream connectivity

20 minutes to unlimited calling within the US

Media Backup Storage Device. Operation Manual

Wespot. SecNurse A NEW GENERATION TECHNICAL AIDS USER S GUIDE

MultiModem ZBA. Quick Start Guide. MT9234ZBA-Series MT9234ZBA MT9234ZBA-V

SwannEye HD Security Camera Wi-Fi Connections Quick Setup Guide. Welcome! Lets get started.

Transcription:

T-MAX Parameter Setting Guide for single 3-A timers and 3-A remote timer systems. Getting into the parameters 1. Remove timer from any other timers (if any). 2. Cycle power to timer. 3. When the timer displays * 0*, press and hold the START/STOP and UP arrow at the same time until the display reads *.1* (Solid decimal, solid one.) Release the buttons. 4. After making any changes to any parameters, press and hold the UP and DOWN arrows at the same time to exit. Note: To exit, there must not be ANY numbers flashing. If there are, press START/STOP to exit that parameter, then try again. Setting bed address 1. Get into parameters mode. (see above) 2. Go to parameter *.1* (solid decimal, solid one). When you get into the parameters mode, you should start off at parameter *.1*. 3. Press the START/STOP button once. The numbers should be flashing. This is your bed address. 4. Use UP and DOWN arrows to change bed address. a. Solid decimal and 0~99 = 0~99 b. Flashing decimal and 0~28 = 100~128 c. Flashing decimal and 52~55 are not bed addresses. d. Setting the bed address to zero *.0* (solid decimal flashing zero) will make that timer a remote timer. 5. Once you have your bed address set, press the START/STOP button once. The display should then read *.1* (solid decimal, solid one). 6. Exit, unless you are making changes to other parameters. Setting the session delay 1. Get into parameters mode. (see above) 2. Press the UP arrow to take you to parameter *.3* (solid decimal, solid three) 3. Press the START/STOP button once. 4. Use the UP and DOWN arrows to set the amount of time, in minutes, that you want to give the person. This is the amount of time they have to get ready before the bed starts. a. Time can be set between 0~10 minutes. 5. Press the START/STOP button once, to set that parameter. 6. Exit, unless you are making changes to other parameters. Enable/ Disable the Clean Room Feature 1. Get into parameters mode. 2. Use the UP arrow to get to parameter *.9* (solid decimal, solid nine) 3. Press the START/STOP button once. A number will start flashing. 4. Set the parameter to a. 0= Clean Room off. b. 1= Clean Room on.

5. Press the START/STOP button once. 6. Exit. Unless you are making changes to other parameters. Troubleshooting A remote 3-A timer with a 3-A T-MAX timer on the bed. Remote 3-A counts down, but the bed timer reads * 0* 1. Get into parameters on the remote timer. 2. Set remote timer s bed address to *.0* 3. Exit parameters. Remote timer displays *39*. 1. Check bed address. Make sure bed address is set to *.1* (solid decimal, solid one). 2. Check timer cord (phone cord) between bed and remote timers. If another timer cord is available, try replacing the existing timer cord. Note: Do not replace timer cords with regular phone cords. They will not work, and may damage the timers. Bed timer (and remote timer if applicable) counts down, but the bed is not coming on 1. Check wire connections a. On the bed timer board (connector marked CONTACT). b. At the bed. Display is dead 1. Is the timer plugged in all the way? 2. Does the timer have it s own power supply? 3. Check power connections on timer board. (connector marked PWR IN 9-12V) 4. Check the wall outlet with another timer, or radio if another timer is not available, to make sure the wall outlet works. T-MAX PLUS/PRO Guide Initial Setup Before you plug in the T-MAX Manager Plus/PRO, make sure each bed has a different bed address. If there are two or more beds with the same address, the T-Max Manager Plus/Pro may not pick that address up and it may get confused and not pick up any other beds. 1. Apply power to the T-MAX Manager Plus/PRO. The T-MAX Manager Plus/PRO will scan the network to find all the 3-As. 2. Press the Call/Menu button. The display should show the following Security #. Enter your level 3 code. A sheet was provided with the T-MAX Manager Plus/PRO with the factory default settings for each security level. 3. The display should read: GET PARAMS? Press Next. 4. The display should read: SEND PARAMS? Press Next. 5. The display should read: MGR PARAMS? Press Enter. 6. The display should read: MGR DELAY TIME. Enter the amount of delay time, in minutes, you give your customers to get ready, then press Enter. (0~10 minutes available. 0= automatic start up.) 7. The display should read: MGR START MODE. a. Enter a 1 if you want the bed to automatically start up when the session delay ends (if any).

b. Enter a 0 if you want the person to have to press the start button in order for the bed to turn on after the session delay. If the session delay ends and the start button has not been pressed, the time will countdown, but the bed will not start until the start button is pressed. c. Enter a 2 if you want to set an infinite delay. The session will only start after the person has pressed the start button, and there is no time limit. d. Press Enter. 8. The display should read: MGR MAX BED. Enter the number of beds that is on your system of timers. Then press Enter. Note: If you only have 6 beds, but are addressed 1,2,3,4,5,and 8; enter 8 on the MAX BED. 9. The display should read: MANAGER NUM. a. If you are only running one T-MAX Manager Plus/PRO, you can either press 0 then Enter, or just press Enter. b. If you are running two or more T-MAX Manager Plus/PRO in a master/slave configuration, you must set the Master to 0, and the other(s) to a unique address (1~8). You will have to do this setup on each T-MAX Manager Plus/PRO individually. 10. The display should read: MGR RE-SCAN TIME. Without entering any numbers, press Enter. 11. The display should read: MAX SLAVE. If you are only using one T-MAX Manager Plus/PRO, then just press Enter. If you are running a Master/Slave configuration go as follows: a. Enter the number of the highest number you set any of the managers to. So if you only had three, and the Master was set to 0, and a slave to 1 and the other slave to 3, the MAX should be 3. The highest number you can enter is 7. 12. The display should read: SAVING PARAMS. It will re-scan for the timers. Enter your level 1 pass code, then the T-MAX Manager Plus/PRO should be ready for use. Call/Menu Functions Pass Code Levels 2. Your default codes should have been provided to you with your T-MAX Manager Plus/PRO. You must enter at least a code of level 1 or higher to send any time to a bed. 3. If a valid code has been entered, there should be an asterisk in the lower left-hand corner of the display. There will be an asterisk for each level of code. a. Level 1= * b. Level 2= ** c. Level 3= *** RE-SCAN 2. Enter 999 then press Enter. After the T-MAX Manager Plus/PRO re-scans, enter you re level 1 pass code. The T-MAX Manager Plus/PRO should then be ready for use. Adding Beds 2. Enter your level 3 pass code, then press Enter. 3. Go through like you are doing the Initial Setup, but when you get to MAX BED, remember to add however many you need. Note: Remember that if you are using non-consecutive bed addresses, to use the highest bed address as your MAX BED number. 4. Finish up with your Initial Setup. Let the T-MAX Manager Plus/PRO Re-Scan, and make sure all the beds are being picked up. Enter your level 1 pass code, then the T-MAX Manager Plus/PRO should be ready for use.

TROUBLESHOOTING Can t Send Time To Bed 1. Make sure you have entered a pass code that is at least a level 1 or higher. There should be at least one asterisk on the lower left-hand corner of the display. 2. Make sure that bed is available 3. Make sure your timer cord is plugged into the T-MAX Manager Plus/PRO and the bed timer. 4. Check to make sure the bed you are trying to send time to has a unique bed address. No Beds Are Showing Up 1. Is the timer cord plugged into the T-MAX Manager Plus/PRO and the first bed in the chain.(if daisy chained) 2. Do all of the timers have power? 3. Do all of the timers have unique bed addresses? 4. Check timer connections to beds. a. Is all of the timer wiring consistent? b. Is any of the timer wire damaged? (Snagged or torn.) Note: A torn timer wire any where in the system could short causing the whole timer system to not work and/or damage the timers and possibly the T-MAX Manager Plus/PRO. c. Is there a good connection to the timer cord ends? (The modular plugs.) d. Are any of the phone jacks on the timer boards damaged? (Usually if the whole timer system is down, and this is the problem, then it would be normally on the first timer in the chain.) One or More Beds Not Showing Up 1. Check bed addresses. 2. If it s the timer(s) at the end of the timer system, check timer wire. a. Is it plugged in? b. Is it damaged? Sends Time To the Wrong Bed 1. Check to make sure you are trying to send time to the right bed. 2. Check station address of the bed(s). Note: This part requires getting into the parameters on the timer itself. Please see instructions for setting bed address. Software For any software related problems, please contact the manufacturer of the software for technical support. Terms Cycle the power- means you need to unplug, or disconnect power to, the timer. We recommend waiting around 10 seconds, then reconnecting. Parameters- settings on the timer that are stored, some are used for information only, while others you can change (bed addresses, clean room feature, etc.) Helpful Hints If you can t get into parameters on a single T-MAX 3-A

1. Make sure the timer is not connected to any other timer or a T-MAX Manager Plus/PRO. 2. Remove power from the timer. 3. With the power removed, press and hold both the START/STOP and the UP arrow. 4. Apply power to the T-MAX 3-A timer. It should beep, and show a display of *.1* (solid decimal, solid one) 5. Release the buttons. You are in the parameters mode.