Multi-Pump and Fan Software Application

Similar documents
NX Series Inverters. HVAC Pocket Programming Guide

SmartVFD Frame 4 Wiring Diagrams and Dimensional Drawings

FlexPak 3000 Digital DC Drive Software Reference Manual Version 4.3

HITACHI INVERTER SJ/L100/300 SERIES PID CONTROL USERS GUIDE

Eaton s E-Series protective relay family

Number 1 in efficiency

GPD 506/P5 Start-up Procedure and Checklist

VLT 6000 HVAC. Contents

Controller Automation, Model II+

VARIABLE FREQUENCY DRIVES Revised 4/30/ Mechanical Systems

SUBJECT: How to wire a motor starter Number: AN-MC-004 Date Issued: 2/08/2005 Revision: Original

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

Product Description Full Voltage Starting Electric Fire Pump Controllers FTA1000

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

What s the Difference? 2 Pipe vs 4 Pipe Fan Coil

C441 series communication modules Accessories for electronic overload relays and soft starters. Monitoring and control made simple

THYRISTORS T1-1PH from 850A to 2700A Specifications Universal 1 Phase Thyristor Unit , March 2012

E-Series protective relay family

NXL Series Inverters. HVAC Inverters made simple

Comparison of NEMA and IEC schematic diagrams

Operational Overview and Controls Guide

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Model: DC-A2IO Advanced HVAC Controller

SECTION 13XXX CONTROL DESCRIPTION (DICP Models NC, 412, 622, 826, 1030)

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Install the DeviceNet Module using the following procedure:

SMS GSM Alarm Messenger

Reverse-feed applications for circuit breakers

GENERATOR START CONTROL MODULE - MINI (2 Wire to 3 Wire)

Torque control MSF Softstarter

NTE2053 Integrated Circuit 8 Bit MPU Compatible A/D Converter

Products and solutions for lifting systems

Programming A PLC. Standard Instructions

Protect IT MNS Motor Management INSUM. MPU - Multi Purpose Unit. - Catalogue - ABB

Limited Service Fire Pump Controllers Features

Analog Servo Drive 25A8

MC Series Drives. Flexible, simple, rugged, robust! Phone: Fax: Web: info@actechdrives.

A1000 Cheat Sheet (Open Loop Vector)

Ordering Part Numbers: Universal Signal Converter: USC-CVB Universal Signal Converter with a 4-20mA input and +/- 10V output: USC-CVB225-B10V

CONSTANT CURRENT REGULATOR INDUPERM TYPE CCR 951. Standarddescription of CONSTANT CURRENT REGULATOR TYPE CCR 951.

SmartVFD HVAC and BYPASS

Product Description Primary Resistance Starting Electric Fire Pump Controllers FTA1500

Product Description Digital Solid State Starting Electric Fire Pump Controllers FTA1930

Industrial Automation Training Academy. PLC, HMI & Drives Training Programs Duration: 6 Months (180 ~ 240 Hours)

Modular I/O System Analog and Digital Interface Modules

NC-12 Modbus Application

Configuring Alarms & Relays in the Enhanced Transformer Advantage

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

Nu-Lec Training Modules

HP 5 Microprocessor Control for Mammoth Water Source Heat Pumps

Datasheet of the Easy Servo Drive ES-D VDC, 8.2A Peak, Close-loop, No Tuning. Version

Products and solutions for pumping, irrigation and piping

The Interaction of Contactors with PLCs

mecotron Safety relay ESTOP-2 For emergency stop monitoring

Specifying a Variable Frequency Drive s

3BASIC RELAY INSTRUCTIONS

Technical Information POWER PLANT CONTROLLER

CHAPTER 11: Flip Flops

AC/DC Power Supply Reference Design. Advanced SMPS Applications using the dspic DSC SMPS Family

Additional Benefits of VFDs In addition to energy savings and better process control, VFDs can provide other benefits:

EET272 Worksheet Week 8

INSTALLATION/PROGRAMMING INSTRUCTIONS E4KP ENTRYCHECK

TwinCAT NC Configuration

DC Motor control Reversing

Unidirectional Transmitter/ Receiver Units Introduction

Electronic Control Devices The European Product Catalogue 2007

ACH550 BCR/BDR/VCR/VDR E-Clipse Bypass Drives. User s Manual. ACH550 E-Clipse Bypass User s Manual 2-1

Series /16 DIN Multi-Mode Bar Graph Display Timer TIMERS PRODUCT HIGHLIGHTS

MOTOR CONTROL IS OUR NATURE

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

SenseLink TM. End-Point Controller. Addendum

MIDECO 64-outputs MIDI note decoder USER MANUAL. Roman Sowa 2012

APPENDIX. SureSERVO QUICK START GUIDE. In This Appendix... Quick Start for SureServo Drives...A 2. Tuning Quick Start for SureServo Drives...

Electrical Symbols and Line Diagrams

XFE. The cost effective starter for all AC induction motors from 4A 2800A The choice for small to medium industrial applications

Installation & Operation Manual for Energenics Air-Flow Optimizer

EXPERIMENT 2 TRAFFIC LIGHT CONTROL SYSTEM FOR AN INTERSECTION USING S7-300 PLC

ZONE SELECTIVE INTERLOCKING (ZSI) APPLICATION AND TESTING GUIDE SIEMENS WL UL489 AND UL1066 AIR CIRCUIT BREAKERS

For a complete explanation of all the functions and configurations available please refer to the SC6006: Manual of operation.

1115 4G SERIES GOVERNOR ma ANALOGUE DIGITAL SPEED SETTING

9000X AF Drives. User Manual. May 2011 Supersedes June 2009

Current Loop Tuning Procedure. Servo Drive Current Loop Tuning Procedure (intended for Analog input PWM output servo drives) General Procedure AN-015

Sierra Dual 24 Volt Brushless DC Motor Controller Product Specification

EATON Diesel Plus Diesel Engine Fire Pump Controller

Fundamentals of HVAC Control Systems

Digital and Analog I/O

Control and Remote Supervision of Sewage Pump Station. AutoLog GSM-RTU and AutoLog ControlMan Web-SCADA Service. Specification V1.

Easy to connect - Easy to configure Easy to install

*.ppt 11/2/ :48 PM 1

ACS800. Master/Follower Application Guide Supplement to Firmware Manual for ACS800 Standard Application Program

Application Technique. Safety Function: Magnetic Door Switch Monitoring

Safety technique. Emergency stop module BO 5988 safemaster

Multi-Range Programmable DC Power Supplies 9115 Series

Programming Logic controllers

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Procidia Control Solutions Dedicated Backup in a Single Variable Control Loop

A relay capable of the generator s starter amps with a coil that draws no more than 12V.

Transcription:

Application Note AP040072EN Multi-Pump and Fan Software Application Introduction The PowerXL DG1 adjustable frequency drive Multi-Pump and Fan Control software application is designed to be utilized in applications where multiple pumps or fan systems are implemented to maintain a desired flow rate, pressure, or temperature value. It enables the drive to use a single PID loop to control auxiliary motors networked together to provide increase power on demand while reducing overall system control cost. The auxiliary motors can be powered by across the line starters, soft starters, or drives depending on the system performance requirements. There are two main features in the Multi-Pump and Fan Control software application: the auto-change feature, which will equalizes the run time of each motor; and the booster mode, that can add additional pumps or fans in periods of higher demand. Both features may also be used simultaneously and a total of five motors can be controlled by one PowerXL DG1 drive. Motor Control Sequence To provide a common example of how the system would operate, refer to Figure 1 and 2 on the next two pages. Figure 1 shows the basic control scheme used for the interlocked contactor system shown in Figure 2. In this configuration, the single PowerXL DG1 drive is controlling two motors. Upstream of each motor is a set of interlocked starters to both isolate and transfer power from the drive to a starter upon demand or vice versa. The interlocked starters are controlled by the relay output terminals on the drive. Once motor 1 ramps up to full speed, if additional demand is required, the second motor can be energized by the starter to provide increased capacity. If this configuration was using the auto-change features, the next time both motors reached zero speed, the interlocks would reverse via the drive relays, making motor 2 controlled by the drive and motor 1 by the starter. This would be done to equalize run time as discussed before. If they system had addition motors beyond these two, the same logic would apply as it system moved from motor to motor for run time equalization.

Application Note AP0400072EN Multi-Pump and Fan Software Application Ref. Output Voltage (+10V) 1 Analog Input 1 (AI1+) 2 Analog Input 1 Ground (AI1-) 3 Analog Input 2 Analog Input 2 Ground (AI2+) (AI2-) 4 5 Transducer (0/4-20mA) I/O Signal Ground (GND) 6 Motor Interlock 1 (DIN5) 7 Motor Interlock 2 (DIN6) 8 PID1 Control Enable (DIN7) 9 Force Remote (TI+) DI5 to DI8 Common (DIN8) (CMB) 10 11 Motor 2 Interlock Motor 1 Interlock I/O Signal Ground (GND) 12 +24 Vdc Output (24V) 13 Ready (DO1) 14 +24 Vdc Output (24V) 15 I/O Signal Ground (GND) 16 Output Frequency Motor Current (AO1+) (AO2+) 17 18 Command +24 Vdc Input (24Vin) 19 Forward (DIN1) 20 Reverse (DIN2) 21 External Fault (DIN3) 22 Fault Reset (DIN4) 23 DI1 to DI4 Common RS-485 Signal A (CMA) (A) 24 25 Motor 2 Start coil RS-485 Signal B (B) 26 Motor 2 Control (R3NO) 27 (R1NC) 28 (R1CM) 29 (R1NO) 30 Motor 2 Control Motor 1 Control (R3CM) (R2NC) 31 32 Motor 1 Start coil Motor 1 Control (R2CM) 33 Motor 1 Control (R2NO) 34 Figure 1: Multi-Pump Two Motor Control Scheme 2 EATON CORPORATION www.eaton.com

Multi-Pump and Fan Software Application Application Note AP040072EN Figure 2: Multi-Pump Two Motor Power Wiring Programming First the PowerXL DG1 application should be set to any application other than Standard (P21.1.2) to enable this functionality, then the initial motor name plate information should be entered into the basic parameter group, this will set up the initial V/Hz curve that the drive will output to the motor. Along with the motor parameters, the control scheme needs to be set for both the Local and Remote control place. Typically this would be set up as follows: P1.10: Local Control Keypad P1.11: Remote Control - I/O Terminal P1.12: Local Reference Keypad P1.14: Remote Reference PID1 Control Upon completion of the basic parameters, the next group to set up is the Analog inputs. In this example we will just us the default values being AI2 set up for 0-20mA (P2.11) and a range of 20-100% (P2.12). If either AI1 or AI2 require being changed from either Voltage or Current, there are dip switches on the side of the control module along with parameters that will need to be adjusted. For more information refer to the PowerXL DG1 Application Manual. Next will be the digital inputs that will require some additional configuration. With the default settings, the application will have the start command given on DIN1 for forward and DIN2 for Reverse. From this point, the number of motors will be need to be known to set up the required number of interlocks. (1 to 5 motors can be used in the sequence, refer to P3.37 to P3.41). These interlocks can be set up on any of digital EATON CORPORATION www.eaton.com 3

Application Note AP0400072EN Multi-Pump and Fan Software Application inputs from DIN3 through DIN8. It is suggested that the default settings be changed so that the functions are disabled in order for the inputs to not have multiple functions. Note: For most inputs, Force Open will cause the function to always be disabled, if Force Closed is used, that function is always enabled. See the PowerXL DG1 Application Manual for more parameter information. Once the I/O control logic is set, then the analog output signal can be set, but it is not required for this particular example. The Relay outputs are used to trigger the interlocked starters to supply power to the auxiliary motors when they are required. Depending on how many motors are in the system will determine how many relays are necessary. For this example, two relays are required for the motor contacts and we will use the third for a run indication. See the PowerXL DG1 Application Manual for more parameter information. P5.2: RO1 Function - P5.3: RO2 Function Motor 1 Control P5.4: RO3 Function Motor 2 Control The next steps would be to set up the PID function for the drive in order to try and maintain a required flow, pressure, or temperature. These values would be set in the PID1 Control group. For this example, the set point will be coming from the keypad P10.14, with the feedback being monitored at AI2 P10.32. The keypad set point would be set at P10.11. The P10 group also has addition values that will allow you for further tuning of the PID loop. After setting up the PID loop parameters the Multi Pump Control parameter can be setup P18 group. This is where the number of motors would be set, in this example there are two. Then the Bandwidth and Bandwidth Delay can be set for how the PID loop is tracked, if the feedback is outside the bandwidth value for the delay time, the drive will use the relay outputs to engage the next motor. In our case, we choose to use auxiliary contacts on the starters to indicate if they are connected, so this needs to be enabled. In addition, the Interlock Auto Change can be set up to equal the run time on each motor by setting up the parameters to control the auto change feature. At this point the drive should be set to run and maintain the set reference value, the system will start out using the first motor and if the set point can t be reached it will bring in the second motor online to assist. Once the auto change time and frequency is met the lead motor will switch. 4 EATON CORPORATION www.eaton.com

Multi-Pump and Fan Software Application Application Note AP040072EN Operation The below images show how the relay output interlock functions are used to tell it which motors are active, and then what the change sequence of motors that are running will be maintain to achieve the required set point. If one of the interlock drops out, the drive will continue to run, but the relay output that controls the starter powering a particular auxiliary motor will drop out. With each motor that is engaged, the main motor will slow down to compensate for the large inrush of bringing a motor on across the line. This helps to allow for improved performance in controlling the flow and these transitions occur based off the bandwidth values and the feedback from the system. Figure 3: Multi-Pump Interlock Control Scheme EATON CORPORATION www.eaton.com 5

Application Note AP040072EN Multi-Pump and Fan Application Additional Help In the US or Canada: please contact the Technical Resource Center at 1-877-ETN-CARE or 1-877-326-2273 option 2, option 6. All other supporting documentation is located on the Eaton web site at www.eaton.com/drives Eaton 1000 Eaton Boulevard Cleveland, OH 44122 USA Eaton.com 2014 Eaton All Rights Reserved Printed in USA Publication No. AP040072EN July 2014 Eaton is a registered trademark of Eaton Corporation. All other trademarks are property of their respective owners