Hardware Installation Guide

Similar documents
T7560A,B,C Digital Wall Module

TR21, TR22, TR23, and TR24 Wall Modules

Electronic Control Devices The European Product Catalogue 2007

ETC TWO STAGE ELECTRONIC TEMPERATURE CONTROL

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

HVAC and Lighting Control Products for Open Building Automation Systems

Installing the Tracer ZN517 Unitary Controller Ordering number: ,

HMI display Installation Guide

MCR1900 Media Converter 19-Slot Chassis

UniStream CPU-for-Panel

Duct Humidity Transmitter

Rack Installation. Unpacking the System. Choosing a Setup Location. General Server Precautions. Barracuda Appliances

Radiant Temperature Sensor TY7321

Serial ATA to Serial ATA

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Electronic Control Devices The European Product Catalogue 2007

MNL-10Rxx Series MNL-15Rxx Series MNL-20Rxx Series

ENCL-MZ800-WAL ENCL-MX800-PAN MNL TAC I/A Series MicroNet MN 800 Series Controller Installation Instructions. Application.

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

Table of Contents. 1 - Specifications Installation Wiring User controls...7

Wireless Alarm System. Panic Button. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

TAC I/NETTM MR-VAV-AX. Application Specific MicroRegulator TM

T0118 T2118 T3118. Instruction Manual

LIEBERT VNSA Installation Sheet

FX07 Field Controller

Short Range Wireless Switch System Handheld 8 Installation and Operations Guide

Installer Guide smart connect

INSTALLATION INSTRUCTIONS

T7079A,B Solid State Remote Temperature Controllers

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Measurement & Control. Features:

Installation Guide. Wyse D Class 4-GB RAM Upgrade Option Kit. Products: D90D7, D90DW. Issue: PN: L Rev. A

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

Advantium 2 Plus Alarm

SMART Board interactive flat panel with appliance Model 8055ie-SMP

STAT-RT Series.

READ THIS MANUAL BEFORE PROCEEDING WITH THE INSTALLATION. FAILURE TO FOLLOW THE INSTALLATION INSTRUCTIONS MAY VOID YOUR WARRANTY!

Drayton Digistat +2RF/+3RF

WIND ALARM. Wind Speed Alarm. Wind Speed. Set Point 2. Set Point 1 NEW BEDFORD, MA USA

Periodic Verification System Model 775PVS

AU-110 racking guide NBXPN: 023

MIC-BP4 Bi-Phase Converter Card For the MIC400 series camera

About the BitStorm 6051 POTS Splitter

INSTALLATION INSTRUCTIONS

Y7230A CO 2 Alarm System

Wireless Alarm System. Wireless Keypad. User s Manual. Choice ALERT. Control all sensors, accessories and remote transmitters from one location

MAKING MODERN LIVING POSSIBLE. AK-SC255 On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

SCREENLOGIC INTERFACE WIRELESS CONNECTION KIT

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

HP 16/18-Port Cable Management Kit Installation Guide

Portable Air Conditioner

INSTALLATION INSTRUCTIONS COMMERCIAL ROOM VENTILATORS WITH EXHAUST

Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

KNX L. Brightness Sensor. Technical specifications and installation instructions Item number 70119

2013 Wireless Video Intercom INSTALLATION GUIDE

Room Controllers. SER8300 Line Voltage Fan Coil Room Controller with SC3000 Relay Pack

GEU Port Gigabit Switch

A99B Series Temperature Sensors

Solid Core and Split Core Adjustable Current Status Switches CSS-O, CSS-C; CSP-O, CSP-C

Installation. Smart-UPS VT and MGE Galaxy Maintenance Bypass Panel with Power Distribution (wall-mount) kva 208 V

Wall-Mounting your HP computer. User Guide

Moxa EtherDevice Switch

PS6500 Storage Arrays Rack Mount Instructions

RI-215A Operator s Manual. Part Number: RK Revision 0 Released: 10/3/05

ScreenLogic Wireless Connection Kit. Installation Guide. pool/spa control system

About this Manual. Support for Your Product

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Senses SV series industrial monitor user manual

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

E-PDD Duct Smoke Detector Installation Sheet

Intel RAID Maintenance Free Backup Unit 4 Quick Installation User's Guide

Replacement Instructions. Warning: During this procedure, keep small parts away from children.

Mounting Plate / Screwdriver. Alignment Stickers Screws / Desiccant Bag / Double-sided Tape / Rubber Seal Plug / Rubber Washer

HP UPS R1500 Generation 3

Front Panel Board Cable Replacement Instructions

DS A 07/99 MN MI I/A SERIES MICRONET INTERFACE APPLICATION SPECIFICATION

Ducoterra Radiant Heating Panel Installation Manual

MicroTech II McQuay Maverick II Rooftop Unit Controller BACnet Communication Module (MS/TP)

RMM2 Heat-Tracing Remote Monitoring Module for the Raychem NGC Control System Installation Instructions

I NTERFACE CABLE ADAPTER MODULE

INSTALLATION INSTRUCTIONS MC95HAE-1 MASTER CONTROLLER

Processor Cage Fans, Front and Rear Replacement Instructions

DS DRTE. AIR ROOM TEMPERATURE SENSOR with fan speed control switches

Wireless Indoor/ Outdoor Thermometer

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Product Catalog BAS-PRC010-E4. Tracker Version 12 Building Automation System. August 2010

EMBEDDED ACCESS CONTROL Hardware Installation Guide

Global Water Instrumentation, Inc.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Power Supply Guide Version 1.0 for D-Show

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

IntesisBox KNX Mitsubishi Heavy Industries AC

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

WIRELESS STATUS MONITOR

OPTICAL HEADEND PLATFORM OTOHP-NMS NETWORK MONITORING MODULE INSTRUCTION MANUAL

CELO5. User & Installation Manual.

D7050/D7050TH. Installation Instructions. Multiplex Photoelectric Smoke Detectors

3 IN 1 BATHROOM HEATER

Cooktop Low-Profile Ventilation Hoods

5800 Temperature Sensor Cable Assembly

Transcription:

Hardware Installation Guide Toll-free: -800-0-00 Tel. International: 0--9898 Allure EC-Sensor Series: Space temperature sensors. Product Description. General Installation Requirements The Allure EC-Sensor series of analog wall sensors is designed to interface with controllers of fan coil, heat pump, roof top and terminal heating / cooling units. These sensors provide precision local temperature measurement with the capability of local setpoint adjustment, fan speed setting, and occupancy override. Each sensor in this series has internal communications terminals to connect it to a LON or BACnet network. In addition, a built-in communications jack exists, allowing a user to connect a computer to the communication network without having to open the sensor s cover. In addition, through this communication jack, an EC-Smart- Sensor-VAV can be used as a hand-held balancing tool to perform VAV airflow calibration. The EC-Sensor s modern, alluring profile enclosure is suitable for classrooms, hotels, executive areas, office spaces and other commercial areas. Mounting hardware with a separate sub-base is provided with the device for installation on a dry wall or on an electrical junction box. This document describes the hardware installation procedures for the following device models: EC-Sensor, EC-Sensor-O, EC-Sensor- S, EC-Sensor-SO, and EC-Sensor-SOF. Unless otherwise indicated, the term EC-Sensor will be used in this document to represent all the models of the Allure EC-Sensor Series. For proper installation and subsequent operation of the EC-Sensor, pay special attention to the following recommendations: - Upon unpacking the product, inspect the contents of the carton for shipping damages. Do not install damaged sensors. - Allow for proper clearance of device enclosure and wiring terminals for easy access, hardware configuration and maintenance. - The device is designed to operate under the following environmental conditions: Ambient temperature from F to F (0 C to 0 C) Relative humidity from 0% to 90%, non-condensing. - Ensure proper ventilation of device and avoid areas where corroding, deteriorating or explosive vapors, fumes or gases may be present. The device must be oriented with the ventilation slots towards the top to permit proper heat dissipation. Any type of modification to any Distech Controls product will void the product s warranty. Take reasonable precautions to prevent electrostatic discharges to the device when installing, servicing or operating it. Discharge accumulated static electricity by touching one s hand to a securely grounded object before working with the device.. General Wiring Recommendations Turn off power before any kind of servicing. - All wiring must comply with electrical wiring diagrams as well as national and local electrical codes. - To connect the wiring to the device, use the terminal connectors which are located inside the device s enclosure. Use a small flat screwdriver to tighten the terminal connector screws once the wires have been inserted. - The board connectors accept wires or flat cables ranging from to AWG (0.6-.60mm diameter) per pole. - It is recommended that all terminals be wired by 8AWG wire except for network communications. Figure -: EC-Sensor-SOF Distech Controls quality management system is ISO 900:000 certified

. Mounting Instructions. Device Components The EC-Sensor has been specially designed for easy installation. However, certain conditions apply when choosing a suitable location for the device: - Install the device in a location of average temperature approximately ft (. m) above the floor - The device should not be installed on an exterior wall. - The device should not be installed near a heat source. - The device should not be installed near an air discharge grill. - The device should not be installed in a place where it can be affected by the sun. - Install the device in an area that provides proper device ventilation. Nothing must restrain air circulation to the device. The EC-Sensor has not been designed for outdoor use. Wall Mounting Installation Procedure The EC-Sensor can be mounted on a dry wall using supplied screws. Remove the security screw from the device (Figure -).. Open the device by pressing in the two () tabs on the bottom of the device and pulling the bottom side of the front plate out.. Pull all cables 6 out of the wall, and insert them through the central hole of the back plate.. Align the back plate with the wall and mark the location of the mounting holes on the wall. Make sure to orient the proper side of the back plate facing upwards.. Remove the back plate and drill holes in the wall if necessary. 6. Install anchors in the wall if necessary. 7. Make sure that the mounting surface is flat and clean. 8. Screw the back plate onto the wall. Do not over tighten. 9. Strip each wire ¼ and insert each one according to the wiring diagrams shown in this document. 0. Gently push excess wiring back into the wall.. Reattach the front plate and make sure it clips tightly into place.. Install security screw. Electrical Junction box Installation Procedure The EC-Sensor can be mounted most American, European and Asian style electrical junction box using screws.. Remove the security screw from the device (Figure -).. Open the device by pressing in the two () tabs on the bottom of the device and pulling the bottom side of the front plate out.. Pull all cables 6 out of the wall, and insert them through the central hole of the back plate.. Screw the back plate onto the electrical junction box.. Strip each wire ¼ and insert each one according to the wiring diagrams shown in this document. 6. Gently push excess wiring back into the electrical junction box. 7. Reattach the front plate and make sure it clips tightly into place. 8. Install security screw. Figure -: Mounting a Smart-Sensor 6. Device Dimensions Unit Legend: mm (inches) Figure 6-: From top left to bottom: Front view, back plate, side view Toll-free: -800-0-00 Tel. International: 0--9898

WIRELESS HIGH 6 7. Device Wiring The EC-Sensor has physical connections for up to four () different features depending on the model. These features include the following: Thermistor Setpoint potentiometer Status indicator Fan speed rotary switch Wiring the 0kΩ Thermistor Terminals and MON are used for the 0kΩ type NTC thermistor, as well as for the override button (not available on EC-Sensor and EC-Sensor-S models). These two terminals are present on every EC-Sensor model. Input MON Figure 7-: 0kΩ NTC Thermistor input NTC Thermistor 0kΩ Override Button The override button creates a short circuit on the controller input, which is interpreted as an override signal. Wiring the 0kΩ Thermistor and the Setpoint Potentiometer Terminals and MON are used for the 0kΩ setpoint potentiometer. These terminals are present on the EC-Sensor-S, EC-Sensor-SO, and EC-Sensor-SOF models. Inputs MON NTC Thermistor 0kΩ Potentiometer 0kΩ Override Button Figure 7-: 0kΩ NTC Thermistor and setpoint potentiometer inputs Wiring a Status indicator Terminals and MON are used to connect a controller output to the status indicator. These terminals are present on the EC-Sensor-O, EC-Sensor-SO, and EC- Sensor-SOF. Vdc Output UO MON Figure 7-: Status indicator output Wiring a Five-Position Fan Speed Rotary Switch Terminals and MON are used to connect the five internal preset resistance values of the fan speed rotary switch to a controller input. These terminals are present on the EC-Sensor-SOF model. The following table shows the five fan speed settings and their corresponding resistance values. MON -position rotary switch Figure 7-: Five-position fan speed input resistors.kω.0kω 7.kΩ 0.0kΩ Wiring a EC-Smart-Sensor to a VAV for Air Flow Balancing (LON controllers only) The communications terminals ( and ) within the EC-Sensor can be connected to the and SMRTinputs of a VAV and facilitate VAV balancing with an EC- Smart-Sensor-VAV. In such a case, the EC-Sensor s communications jack would have to be used. To wire an EC-Smart-Sensor-VAV to a VAV via an EC- Sensor do the following:. Remove the front plate of the EC-. Connect the communications terminals ( and ) to the and SMRT- terminals of the VAV controller.. Remove the back plate of the EC-Smart-Sensor-VAV.. Connect the two () wires that terminate with the ⅛" audio cable to the and SMRT terminals of the EC-Smart-Sensor- VAV.. Insert the ⅛" audio cable into the communications jack of the EC- ECC-VAV LONWORKS LON LON SMRT- UO DO C- DO DO C- DO VAC V MON /8" SMRT Figure 7-: Wiring EC-Smart-Sensor to a VAV for airflow balancing The communications jack for both the EC-Smart-Sensor and EC-Sensor support mono and stereo audio cables. LON LON /8" Fan Speed Setting Auto Off Fan speed Fan speed Fan speed Corresponding Resistance Value 0Ω.kΩ.0kΩ 7.kΩ 0.0kΩ Toll-free: -800-0-00 Tel. International: 0--9898

WIRELESS HIGH 6 WIRELESS HIGH 6 Wiring an EC-Sensor to a LON network for Technician Use The communications terminals (, ) within the EC- Sensor can be optionally wired to a controller in a LON network To access the LON, a laptop can be connected to the EC-Sensor s communications jack by means of a ⅛" audio cable. If the distance between the EC-Sensor and the controller (Ttap length) is greater than 0ft (m), a bus topology must be used. The following figure shows how the EC-Sensor in bus topology LON network: AWG (0.6mm) unshielded twisted pair network cable The recommended cable type for LON communications is AWG (0.6mm), twisted pair, unshielded. The following figure shows how the EC-Sensor is connected in LON network with less than 0ft (m) T-tap length: Bus-topology network EC-Sensor AWG (0.6mm) unshielded twisted pair network cable <0ft (m) Bus-topology network Figure 7-6: LONWORKS Network Bus Topology with T-tap To wire a laptop to the LONWORKS network with T-tap via an EC-Sensor, do the following:. Remove the front plate of the EC-. Connect all three () LON cables coming from the previous device, going to the next device and going to the EC-Sensor to the LON and LON input terminals on the controller. If inserting multiple wires in the terminals, ensure to properly twist wires together prior to inserting them in the terminal connectors.. Connect the LON network cable coming from the controller to the and terminals on the EC-. Connect the two () wires that terminate with the ⅛" audio cable to the output terminals of the LonTalk adapter of the laptop.. Insert the ⅛" audio cable into the communications jack of the EC- ECC-VAV LONWORKS LON LON SMRT- UO DO C- DO DO C- DO VAC V From Previous To Next MON EC-Sensor Figure 7-8: LONWORKS Network Bus Topology To wire a laptop to a bus topology LONWORKS network via an EC-Sensor, do the following:. Remove the front plate of the EC-. Connect the LON cables coming from the previous device and going to the EC-Sensor to the LON and LON input terminals on the controller. If inserting multiple wires in the terminals, ensure to properly twist wires together prior to inserting them in the terminal connectors.. Connect the LON cables going to the next device and coming from the controller to the and input terminals on the EC- If inserting multiple wires in the terminals, ensure to properly twist wires together prior to inserting them in the terminal connectors.. Connect the two () wires that terminate with the ⅛" audio cable to the output terminals of the LonTalk adapter of the laptop.. Insert the ⅛" audio cable into the communications jack of the EC- ECC-VAV LONWORKS LON LON SMRT- UO DO C- DO DO C- DO VAC V From Previous To Next MON /8" /8" Figure 7-9: Wiring EC-Sensor to a LONWORKS Network Bus Topology Figure 7-7: Wiring EC-Sensor to a LONWORKS Network Bus Topology with T-tap For information and detailed explanations on network topology and wire length restrictions, please refer to the Junction Box and Wiring Guideline for Twisted Pair LONWORKS Networks, published by Echelon. Toll-free: -800-0-00 Tel. International: 0--9898

HIGH Wiring an EC-Sensor to a BACnet network for Technician Use The communications terminals (,, and ) within the EC-Sensor can be optionally wired to a controller in BACnet network. To access the BACnet networks, a laptop can be connected to the EC-Sensor s communications jack by means of a ⅛" audio cable. The recommended cable type for BACnet communication is AWG (0.mm), twisted pair, shielded. The following figure shows how the EC-Sensor is connected in BACnet network: ECB-VAV SUBNET VDC UO DO C- DO DO C- DO VAC V From Previous To Next MON /8" AWG (0.mm) shielded twisted pair network cable Bus-topology network EC-Sensor Figure 7-0: Wiring EC-Sensor to a BACnet network To wire a laptop to the BACnet network via an EC-Sensor, do the following: Figure 7-: Wiring EC-Sensor to a BACnet Network Bus Topology For information on best practices, specifications, and wiring rules, please refer to the BACnet Network Guide.. Remove the front plate of the EC-. Connect the BACnet cables coming from the previous device and going to the EC-Sensor to the and input terminals on the controller. Maintain consistent wire polarity. If inserting multiple wires in the terminals, ensure to properly twist wires together prior to inserting them in the terminal connectors. Also, connect the shield of the two () cables together while keeping it as short as possible.. Connect the BACnet cables going to the next device and coming from the controller to the and input terminals on the EC- If inserting multiple wires in the terminals, ensure to properly twist wires together prior to inserting them in the terminal connectors. Also, connect the shield of the two () cables to the input terminal on the EC-. Connect the three () wires that terminate with the ⅛" audio cable to the output terminals of the BACnet/IP to MS/TP Adapter.. Insert the ⅛" audio cable into the communications jack of the EC- Toll-free: -800-0-00 Tel. International: 0--9898

Hardware Installation Guide - 0DI-HIECSEN-0 EC-Sensor, EC-Sensor-O, EC-Sensor-S, EC-Sensor-SO, EC-Sensor-SOF Copyright Distech Controls Inc. First printed July 00 While all efforts have been made to verify the accuracy of information in this manual, Distech Controls is not responsible for damages or claims arising from the use of this manual. Persons using this manual are assumed to be trained HVAC specialist / installers and are responsible for using the correct wiring procedures and maintaining safe working conditions with fail-safe environments. Distech Controls reserves the right to change, delete or add to the information in this manual at any time without notice. Distech Controls and the Distech Controls logo are trademarks of Distech Controls Inc. Echelon, LON, LonTalk, LONMARK and LONWORKS are registered trademarks of Echelon Corporation registered in the United States and other countries. BACnet is a registered trademark of ASHRAE. *0DI-HIECSEN-0* 0DI-HIECSEN-0 Toll-free: -800-0-00 Tel. International: 0--9898