Vickers Solenoid Operated Directional Valves



Similar documents
Char-Lynn Hydraulic Motors. Repair Information. W Series Geroler Motors 002, 003. April, 1999

Char-Lynn Disc Valve Motors. Parts Information Compact Series

Solenoid Operated Directional Valves

Solenoid Operated Directional Valves

Directional Controls. Solenoid Operated Directional Valve DG4V-3S, EN 490 For Mobile Equipment

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

DIRECTIONAL CONTROL VALVES

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Vickers. Overhaul Manual. Directional Controls. Directional Control Valves. DG3V-8/DG5V-8 Hydraulic/Solenoid Pilot Operated 5007.

Industrial Valves. Marketing Catalog. Reliable and continuous performance in the world's most demanding and rigorous applications.

PVH131/141 Variable Displacement Piston Pump - 11 Design

Pressure Relief Valves for Pipe Mounting

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

5 Port Pilot Operated Solenoid Valve Rubber Seal. Specifications Fluid Operating pressure range. 2 position single/3 position 2 position double

Directional Control Valves

Directional Controls

Dual Path Mobile Pump

Electro-pneumatic control valves

Line-Mounted Valves L Series

Pressure Relief. Pressure Relief Valves. Vickers

3/2 Solenoid Cartridge Valve, Size 6

PVM Piston Pumps Service Manual

FT1380 & FT1390 Crimp Machines

3 Port Solenoid Valve

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

4 Posiflow Proportional Solenoid Valves

SOLENOID VALVES 3-4 WAY

Unit 24: Applications of Pneumatics and Hydraulics

2/2 and 3/2 Way Size 6 Seat Valves

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Proportional Pressure Reducing Valves

Assisted lift operated 2/2-way solenoid valves Type EV250B

2.12. page Products for Explosion hazardous Environment

3 Port Solenoid Valve

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

System 8. ü ( System 8

PVQ 40-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 PVQ 45-B2/M2 * *** - ** * * - 10 C**

UM/ /2 or 5/3 Solenoid and air pilot actuated soft spool valves

Denotes New Winner s Circle Product Line. Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI HIGH FLOW VALVE FAMILY

Chapter 6: Check Valves

2 WAY (2/2) AND 3 WAY (3/2) BRASS AND STAINLESS STEEL SOLENOID VALVES

Automated Lubrication Systems Parts & Accessories

Valves. Sub-Base Mounted Valves to ISO 5599/2

For latest information, PDF catalogs and operation manuals Features MPa {kgf/cm 2 } {175}

Round Housing with Side Ports

3 WAY (3/2) POPPET VALVES FOR AIR AND VACUUM SERVICE SOLENOID OR AIR ACTUATED BROCHURE N-223

Control block EDD Modular Directional Valve

SOLENOID VALVES AND PNEUMATIC VALVES

3/2- and 2/2-way cartridge valve type BVE

RA / Functional description 1/10. 4/3-, 4/2- and 3/2 Directional Control Valves Model WE 6.. /E, Series 6X with wet pin AC or DC solenoids

Inrush Apparent power (VA) Flow Characteristics/Weight. Port size Rc. Valve model VS VS VS VS VS

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

820 NOVA mv THERMOPILE POWER SUPPLY THERMOELECTRIC SAFETY DEVICE SERVO-CONTROLLED PRESSURE REGULATOR SHUT-OFF SOLENOID VALVE.

Single sub-base valve

Model 4418F. Overview. Typical applications. Key features and benefits. Accreditations. Starting air/gas valve Vented fuel gas valve

STC 3S A Series Solenoid Valves

Fluid Level Gauge Fluid Level Sensor Temperature Switch FSA / FSK / TS

size size

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Series Hose Reels

3/2-way Solenoid Valve, direct-acting, NC or NO

Cable Plug acc. to DIN EN , Form A

MDT5N25 & MTD5N40 SERVICE PARTS

PSS10H/B PSS12H/A ILLUSTRATED PARTS LISTS

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

2 position single. (Standard) 100V AC 50/60Hz 200V AC 50/60Hz 24V DC. 2 position double

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Electro-Pneumatic Bus Door Control Mechanism

IOM SERIES 820-E/P Electro-Pneumatic Positioner

On-off valves MS-EM/EE, MS series, NPT

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

AFE424 SERVICE PARTS

Port Solenoid Valve. Series VQZ100/200/300. Compact, High Flow. Power consumption: 0.35 W/0.9 W SYJ VQZ VP VG VP3

Safety for Hydraulics Leak free check valve, pilot operated, series ERV Cartridge type, two stage

INSTALLATION AND OPERATING INSTRUCTIONS For Model GL1 Gate Locks

Proportional Pressure Relief Valves

D. PARAMETER SPECIFICATION Measured Variable: Displacement

Chapter 5: Flow Valves

Table of Contents. MicroAir Series...3-9

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

zamak nitrile rubber self-extinguishing technopolymer aluminum

UM/ /2 & 5/3 valves, solenoid and pilot actuated ISO , ISO size 1, 2, 3 & 4 Sub-base mounted

7.1. Part Lists. Hardware Insertion Machine. Instructions. Instructions

Pressure relief valves Size 6

Air Vantage 500 Kubota

solenoid valves SV Series 2- and 3-way Solenoid Valves for Gas and Liquid

Installation Instructions

Parts. Ultra 395/495/595t Ultra Max II 490/495/595t V 120 VAC psi (228 bar, 22.8 MPa) Maximum Working Pressure.

SERVICE & OPERATING MANUAL ELECTRONIC LEAK DETECTOR WARNING VDC

RC 195 Multiple Input Receiver-Controller

Load-sensing control block in mono and sandwich plate design

Vickers. Overhaul Manual. Relief Valves. Balanced Piston Relief Valves. CG/CS/CS5-03/06/10 Series CT/CT5/CG5-06/10 Series

Transcription:

Vickers Solenoid Operated Directional Valves Parts Information Optimized - Soft Shift Function DG4V-3 -**(L) 3 - (P2) - (V) M - ****(L) - **H * - 60 - (P* - A* - B* - T*) ISO 4401, Size 03; ANSI/B93.7M-D03

Model DG4V-3-**(L) 3 Knob 998330 Core Tube S/A 02-344643 Restrictor Plug Install In P,T,A, Or B As Required CODE ORIFICE DIA. PART # 03 06 08 10 13 15 20 23 0,30 (0.012) 0,60 (0.024) 0,80 (0.030) 1,00 (0.040) 1,30 (0.050) 1,50 (0.060) 2,00 (0.080) 2,30 (0.090) 694341 694342 694343 694344 694345 694346 694347 694348 473710 Screw W/J models (2 Req'd) 473269 Screw P12L models (2 Req'd) Nameplate (see table) 02-113349 Screw (4 Req'd F models) 471277 Screw (2 Req'd U models) 348670 Screw (4 Req'd P12L models) 890333 Cover W/J models 890331 Gasket W/J models 890330 Strap W/J models 36212 Screw (2 Req'd) W/J models Terminal/Conduit box (See table) 890332 Gasket W/J models 471027 Washer P12L models (2 Req'd) 262327 O Ring P12L models (4 Req'd) C models 576915 Screw (ground) W/J models Body 507731 507731 866039 Type Flying lead coil Din 4400 coil Plug in coil Body (See table) 262342 O" Ring Plug in coil P12L" (see table) (1 req'd) A & B, (2 req'd) C models. Flying lead coil F" (see table) (1 req'd) A & B, (2 req'd) C models. 262332 O" Ring (4 Req'd) Core Tube S/A (see table) (includes push pin) 262353 O" Ring DIN 4400 coil (shown) (see table) U,KU,SP1,SP2 (1 req'd) A & B, (2 req'd) C models. 262392 O" Ring Knob (see table) 2 Orfice plug (see table) 472553 Roll pin Spool (see table) 458458 Washer Spring (see table) Omit A models this end Available in seal kit 858996 Omit for Din models Included in CoreTube S/A Available in qty's. of 25 or more only Not available for sale Torque 44-62 lbf. ft.(5,0-7,0 N.m) Torque 18-25 lbf. in.(2,3-2,8 N.m) Torque 22-27 lbf. ft.(30-36 N.m) Torque 21-26 lbf. in.(2.5-3.0 N.m)

Blank Nameplates (DG4V-3-60 High Performance Valve) Model Code DG4V-3-***-**-M-U-*7-60 DG4V-3-***-**-M-U-*2/*6-60 DG4V-3-***-**-M-F/FPA3/FPA5-*7-60 DG4V-3-***-**-M-FPB-**-60 DG4V-3-***-**-M-FPBL-**-60 DG4V-3-C/N**-**-M-P-**-60 DG4V-3-A/B/F**-**-M-P-**-60 DG4V-3-AL/BL/FL**-**-M-P-**-60 For more information on options refer to service drawing I-3886-S. Nameplate 694303 694451 694387 865929 865930 865933 865934 865935 507908 Plug 262353 O" Ring Spring (See table) 458458 Washer 676560 Plug (2 Req'd) DG4V-3-*A3 -(V)M-FW-60 Spring offset to CYL. A, shift to center. DG4V-3-*B3 -(V)M-FW-60 Spring centered, Sol. A removed. Refer to other end of valve for common part numbers except as noted. DG4V-3-*C3 -(V)M-FW-60 Spring centered, dual solenoid. Refer to other end of valve for common part numbers except as noted. NOTE Right hand assembly shown for all single solenoid valves, for left hand assembly all parts reversed except body (& spool on B builds) and electrical connectors (where applicable). 507972 Plug & manual overide S/A 262353 O" Ring Spring (See table) 1 req'd 458458 Washer 676560 Plug (2 Req'd) Model Code Coil Identification Letter Coil letter GH DTH HH DJH PH SH Voltage DC 12 VDC 18 VDC 24 VDC 98 VDC 110 VDC 220 VDC F models 02-123958 02-124394 02-123959 02-123960 02-123961 02-124260 U models 02-123938 02-124392 02-123939 02-123940 02-123941 02-124441 SP1 models 02-123950 02-124719 02-123951 02-123952 02-123953 SP2 models 02-123942 02-124389 02-123943 02-123944 02-123945 DG4V-3-*A3 -*P2-(V)M-FW-60 Manual override in end cover. Refer to other end of valve for common part numbers except as noted. KU models 02-140393 02-148712 Type F flying lead coils must be powered by DC electrical signal. Type P12L coils must be powered by 110-120, 50-60 Hz AC. DIN rectified connectors ( 11" or 12" in model code) can be used to convert AC volts to DC voltage to power the valve. P12L models 02-124274 02-124511 02-124275 02-124238 02-124276 3

Model Code DG4V3-A/B/C-W DG4V3-A/B/C-J DG4V3(S)-C-P12L DG4V3-A/B-P12L Terminal Box W/J Flying lead 890341 890342 Conduit Box P12L Plug in 866000 866001 Type Single/double coil Double coil with rectifier Single coil with rectifier Rotate conduit box/rectifier/light assembly 180 for models AL, BL, and 8B with solenoid mounted on B port side of body. Spool/Spring Arrangement DG4V3 Models Model Type DG4V3 Spool DG4V3 Spring -*B/C -*A 2* 3*/31* 6* 8* 33* 0* 2A 892913 927027 892914 02-303660 892915 02-148720 892916 694299 927200 Assemble type 3 spool in body with narrow center land towards A port. Assemble type 31 spool in body with narrow center land towards B port. 4

DG4V-3 Soft Shift Model Series DG4V - 3 - * * (L) 3 - (P2) - (V) M - * * * * (L) - *** 7-60 - (P*-A*-B*-T) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1 Valve Type D - Directional control valve G - Subplate mounted 4 - Solenoid operated V - Rated pressure (350 bar) 2 Interface 3 - ISO 4401-03, CETOP 3 (NFPA D03) (High performance only) 3 Spool Types 0 - Open center 2 - Closed center (all ports) 3 - P & B closed, A to T 6 - Closed center (P only) 8 - Tandem center (open crossover) 31 - P & A closed, B to T 33 - Closed center (bleed A & B) 4 Spool/Spring Arrangement A - Spring offset, single solenoid AL - Spring offset, single solenoid (left hand build) B - Spring centered, single solenoid BL - Spring centered, single solenoid (left hand build) C - Spring centered 5 Soft Shift Valve - Optimized Fixed Orifice 6 Manual Override Blank - Override in solenoid end only P2 - Manual override in end cap and solenoid, A & B models only. 7 Solenoid Energization identity Blank - ANSI B93 energize solenoid A to give flow P to A V - Solenoid identification determined by position of solenoid (i.e. solenoid A is at port A end of valve, solenoid B is at port B end of valve.) 8 Flag Symbol (Introduces electrical features and options) 9 Coil Types F - Flying lead type coils U - DIN 43650 coils SP1 - Single 1/4" male spade SP2 - Dual 1/4" male spade P12L - Plug-in coils w/rectifier in junction box, lights included. KU - Top exit flying leads 10 Coil Connectors ( U type coils only, omit if not required) 1 - Connector fitted 6 - Connector with light fitted 11 - Rectifier with lights fitted 12 - Rectifier fitted 11 Electrical Connections ( F type coils only, omit if not required) PA - Insta-plug male recpt. only PA3-3-pin receptacle PA5-5-pin receptacle PB - Insta-plug male & female recpt. T - Terminal block 5 12 Wiring Housing Thread ( F type coils only, omit if not required) W - 1/2" NPT J - M20 x 1.5-6H G - G1/2 13 Solenoid Indicator Lights (Not available on PA, U, SP1, SP2. Omit if not required.) 14 Coil Identification Letter GH - 12V DC DTH - 18V DC HH - 24VDC DJH - 98V DC (req d. for P12L models) PH - 110V DC SH - 220V DC 15 Tank Pressure Rating 7-210 bar (3045 psi) 15 Design Number 17 Port Orfices Blank - 00 03-0.3 mm dia. 06-0.6 mm dia. 08-0.8 mm dia. 10-1.0 mm dia. 13-1.3 mm dia 15-1.5 mm dia. 20-2.0 mm dia. 23-2.3 mm dia. (Example: P03 = 0.3 mm dia. orifice in P port of valve. Omit if not required.)

This page left blank intentionally 6

This page left blank intentionally 7

Eaton Fluid Power Group Hydraulics Group USA 14615 Lone Oak Road Eden Prairie, MN 55344 USA Tel: 952-937-9800 Fax: 952-294-7722 www.eaton.com/hydraulics Eaton Fluid Power Group Hydraulics Group Europe Route de la Longeraie 7 1110 Morges Switzerland Tel: +41 (0) 21 811 4600 Fax: +41 (0) 21 811 4601 Eaton Fluid Power Group Hydraulics Group Asia Pacific 11th Floor Hong Kong New World Tower 300 Huaihai Zhong Road Shanghai 200021 China Tel: 86-21-6387-9988 Fax: 86-21-6335-3912 2009 Eaton Corporation All Rights Reserved Printed in USA Document No. V-VLDI-TP002-E Supersedes 06-05-0001 EN 301 March 2009