Spelsberg Electrical circuit integrity at its best



Similar documents
PV-Lifeline Safety in case of danger

Passive Fire Protection

Tremco Fire Protection Systems Group Technical Bulletin

Composite Panel Firewall Systems

Introduction to cable fire stopping

CERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES

Excerpts from the Canadian National Building Code (NBC)

Fire Barriers & Fire Stopping

FIRESTOPPING. Cable. Firestopping is the technology used to

Fire Collars For Plastic Pipe Penetration

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

CERTIFICATE OF APPROVAL No CF 291 SCHOTT UK LIMITED

FIRESTOPPING & SMOKE SEALS

Flamesafe Firestopping Products. Firestopping Products.

Terms and Definitions In Canada

SECTION SECTIONAL OVERHEAD DOORS 521 SERIES ALUMINUM SECTIONAL OVERHEAD DOORS

Decree of the Ministry of the Environment on fire safety of ventilation systems

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

GPD Rubber Press Seals

GENERAL SHIELDING REQUIREMENTS FOR DIAGNOSTIC X-RAY FACILITIES. Major Medical (Radio/Fluoro/CT/Cardiac/Chiropractic)

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

WHI 90-Minute Rated Veneered Door Frame Installation Instructions

H45 LED - Direct and indirect pendant

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

12.1 Schlüter -KERDI-BOARD

sound reduction systems for commercial, educational and industrial environments

Company and Product Presentation

FLASHMAN WINDOW AND DOOR FLASHING SYSTEM. Product. Scope. Appraisal No. 573 [2013]

LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market

Services Enclosures and Protected Shafts - Maintaining Compartmentation

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

MERO Floor Systems - CleanRoom

800 Communications Circuits

Comprehensive safety concepts for building applications

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

2.8. Ex-Recess-mounted, ceiling emergency light fittings in compact metal design

opti-drän system Keeps your basement and building dry

Installation information. METTLER TOLEDO MultiRange DW150 / DW150T wall scale

Rf-Technologies welcomes you on its stand U48-50 (Hall 15) at the Mostra Convegno tradeshow, Fiera Milano, from 27 till 30 March 2012

How to build a Pizza Oven in 4 days

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

GYPSUM AREA SEPARATION FIREWALLS GA

Catalog Number Pillow Type Pillow Size

Terminal Boxes Series 8146

SECTION COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

NoteBox NoteBox with room for 16 tablets

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

INSTALLATION INSTRUCTIONS: Viewline 52 mm

Fire Barrier Duct Wrap 15A

C05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction

Hanson Building Products. precast basement solutions

PB301 July Lightweight Building Solutions. Bushfire Protection.

Sealfire W1000 Compound. (2 references for the same product) Fire Stopping and Sealing Product: Penetration Seals

Isover HVAC Application Handbook Installing fire protection insulation to metal ductwork

PRESENTATION ON REPAIR AND REHABILITATION OF BUILDINGS DAMAGED IN EARTHQUAKE. By H P Gupta & D K Gupta

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: JUNE 27, 2012

Mark Cramer Inspection Services, Inc.

2.9 WINDOW & DOOR BUCKS

Re-Enterable Solutions. Permanent Solutions. Fail Safe Firestop Solution

Blown Fibre Tube Cable Connectivity

MODEL HSR-007 Direct Drive Rolling Steel

nr 28 nr 68 nr 4 nr 1

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

Installation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details

NoteBox NoteBox with room for 16 tablets

GENERAL FIRE SAFETY TERMS & DEFINITIONS

ITS specification Jointing chambers and pull pits (ITS-02-02)

European Organisation for Technical Approvals

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

Product Information. Tel: x2426 or x2443 Fax:

FIRE RATED GLAZING System Guide

Installation Instructions

GK Packing System Welding Instructions

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

STRUCTURAL CONCEPT FOR LIGHT GAUGE STEEL FRAME SYSTEM

SCHOTT PYRANOVA Planline System

Sliding and Folding Door Fittings Sliding Door Accessories

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Schluter -KERDI-BOARD Substrate, building panel, bonded waterproofing

Knauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap

Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D.

Chimney systems ICOPAL WULKAN C/CI/C-eko/CI-eko

DUCT SMOKE DETECTOR D4120

IMPACT DAMAGE RESISTANT WALL SYSTEMS

1.1 SYSTEM DESCRIPTION.1 Data system includes data outlets and wiring for office and school applications.

NATUS NES / NES-H Draw-out Type Medium Voltage Switchgear Systems. Safe energy distribution that meets the highest industrial requirements


Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

Product Catalogue HW-B150H

Security steel door dw 52-1 Teckentrup DF WK 2 optionally with glazing/ventilation grille

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Rockwool Flexi Insulation Application Guide

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

Transcription:

WKE - FlexBox

Reliability and safety these are the most important requirements on electrical systems in modern buildings. That is especially true in case of fire, where Spelsberg products play a critical role in sustaining electrical circuit integrity. They delay the spread of smoke and fire and ensure that important safety equipment remains available during a fire. Cable penetration seals, junction and connection boxes, and small distributors from Spelsberg are part of safety planning for buildings all over the world. They protect sensitive electronics from fire, heat, smoke and moisture. Tested, proven, reliable. 2 Spelsberg Electrical circuit integrity at its best

FlexBox - highest standards in firestopping Cables and wires form a network throughout a building. In some cases, this network leads through walls that separate fire compartments. In spite of the resulting penetration, these walls must retain their fire resistance rating so that neither smoke nor fire can advance into protected areas: not a problem for the FlexBox cable penetration seal from Spelsberg. Fast, flexible, safe FlexBox is a ready-to-install cable penetration seal for varying wall thicknesses. No matter how large the opening or how thick the wall, the versatile cable penetration seal is easily installed. Its galvanised sheet steel housing with adhesive-mounted circumferential intumescent strips protects the cables passing through it. Two sealing plugs made of insulation-forming foam plastic seal off the external sides of the wall; in a fire, the material foams up and reliably prevents ingress of fire and smoke. 3

Applications Especially suitable for: Temporary or permanent firestopping for single cables or cable bundles up to Ø 60 mm Small firestops in light partitions with standard diameters (68 mm, 74 mm and 100 mm) created with hole saws. Additional frames of non-combustible structural panelling are no longer needed. Rooms sensitive to fibres and dust and sites with frequently changing electrical installation F90 wall: Installation in walls at least 10 cm thick, of masonry, concrete, reinforced concrete or aerated concrete, or light partition walls at least 10 cm thick Installation in light partition walls without jamb Through-penetration by empty conduits, with or without cabling Examples: IT facilities, hospitals, laboratories, warehouses, shopping centres, office buildings, industrial buildings, airports, factories Permissible firestop size: Arrangement of up to 9 FlexBoxes (3 x 3), resulting in a total area of 306 x 306 mm (outside) plus mortared edge joint 4 WKE FB FlexBox S90

Installation notes Clean the wall opening Fit the WKE FB snugly Fit the WKE FB sealing plugs Fill in and mount the firestop plate 2.5 cm maximum > 10 cm wall thickness The FlexBox can also be mounted flush with the wall on one side if the wall is at least 125 mm thick. Advantages Safe, ready-to-install cable penetration seal Fast and easy handling No jamb with light partition walls Sizes to match hole saws Non-destructive retrofitting Suitable for protection of existing cabling Easy installation with little effort Handling without dust and fibres Especially suitable for frequent retrofitting 5

Ready-to-install cable penetration seal for wall bushings to provide firestopping for single or bundled electrical cables and wires of all kinds (also fibre optic cables) as well as waveguides. Individual steel and plastic tubes 63 mm as well as RZD multitubes. Installation in walls at least 10 cm thick, of masonry, concrete, reinforced concrete or aerated concrete. Suitable for light partition walls at least 10 cm thick. Installation in light partition walls without jamb. 6 WKE FB FlexBox

WKE FB 01 Order no. 860 331 01 EAN 4013902 830 244 Outside diameter: 100 mm Inside diameter: 90 mm Length: 150 mm WKE FB 10 Order no. 860 321 01 EAN 4013902 830 237 Width: 100 mm Inside width: 90 mm Height: 100 mm Inside height: 90 mm Length: 150 mm WKE FB 06 Order no. 860 333 01 EAN 4013902 830 268 Outside diameter: 68 mm Inside diameter: 58 mm Length: 150 mm WKE FB 07 Order no. 860 332 01 EAN 4013902 830 251 Outside diameter: 74 mm Inside diameter: 64 mm Length: 150 mm 7

Günther Spelsberg GmbH + Co. KG VK20829-XXXXXX-0811-PDF Visit us at facebook! www.facebook.com/spelsberg.de Follow us at twitter! www.twitter.com/spelsberg Headquarter Im Gewerbepark 1, D-58579 Schalksmühle Postfach 15 20, D-58571 Schalksmühle Tel.: +49 (0) 23 55 / 8 92-0 Fax: +49 (0) 23 55 / 8 92-299 e-mail: info@spelsberg.de Internet: www.spelsberg.de Branch Office Vor dem Lohe 3, D-99628 Buttstädt Postfach 30, D-99627 Buttstädt Tel.: +49 (0) 3 63 73 / 98-400 Fax: +49 (0) 3 63 73 / 98-499