LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market
|
|
- Cassandra Harrington
- 8 years ago
- Views:
Transcription
1 LPCB Red Book Listed Products and Passive Fire Protection Installer Schemes Answering the needs of the market Ian Stewart Passive installer scheme manager September 2011
2 Introduction to BRE Global Research, innovation, consultancy, fire testing, certification, related installers, training. Working in the built environment, but also transport, manufacturing, electronics, agriculture
3 Our national and international standing Customers in 38 countries and recognised in 42 World-class facilities and experts Involved in the development of regulations, codes and standards Advisors on policy One-stop shop for testing and certification Strong links with industry and authoritative bodies
4 Why is passive fire protection in buildings so important? Maintains structural stability of steel frame buildings Reduces deflection of floors Maintains compartmentation Reduces spread of smoke Maintains escape routes What happens if it fails? Potential building collapse Potential loss of life Major rebuilding cost
5 The Red Books Products and services approved by us are listed in the Red Books Volume 1 Fire Detection and Alarm products and services. Related installers. Volume 2 Passive fire protection products and services. Security protection systems. Related installers. Management systems. Construction products. Available on-line at CD and hard copy
6 LPCB Passive installer schemes Installer schemes are available in the form of Loss Prevention Standard (LPS) for the following Passive Fire Protection products :- Fire doors (Maintenance and repair) LPS 1197 Fire shutters (Maintenance and repair) LPS 1197 Smoke barriers (Maintenance and repair) LPS 1197 Fire doors (Installation) LPS 1271 Security doors (Installation) LPS 1271 Fire shutters (Installation) LPS 1271 Smoke barriers (Installation) LPS 1271 Compartment wall systems (LPS 1208 tested) LPS 1500 Penetration, cavity barriers and linear gaps LPS 1531 Board fire protection LPS 1531 Intumescent coatings LPS 1531 Spray fire protection LPS 1531 Fire rated ductwork LPS 1531 Fire resistant dampers LPS 1531 Fire rated compartment walls LPS 1531 Offsite applied intumescent coatings LPS 1531
7 Why Passive installer schemes? Reduces the risk of loss of life and product failures by ensuring professional installation Reduces damage caused to property and hence insurance losses should a fire occur Allows installers to comply with AD-B Vol2 Encourages insurers and building control that fire safety has been given appropriate consideration Reduced liability
8 Benefits of Passive installer schemes Reduces risk for manufacturers, end users, insurers, clients, specifiers, contractors, legislators Differentiation for installers Installer self certifies his work Encourages maintenance of passive via O&M manuals Regulatory Reform order Reduced liability Create a level playing field for installers
9 LPS 1500 LPS 1500 Issue 2.0 Requirements for the LPCB Approval and Listing of companies installing fire resistant compartment wall systems in buildings This standard defines the requirements for companies installing fire resisting compartment walling systems approved by LPCB to the requirements of LPS 1208.
10 LPS 1500 New installer scheme specifically for the installation of LPCB Approved Composite Construction Elements. Load-bearing compartment walls and partitions Non Loading bearing compartment walls and partitions External wall Curtain wall Cavity Barriers Roofs (where fire resistance is required) Load-bearing compartment floors Insulated Panels for enclosing production and storage areas in food factories.
11 Typical composite panel application Screw fixings to steel Fast fire wall construction
12 Summary of LPS 1500 New Approach to Schemes for the Installers of Passive Fire Protection. Provides a link between LPCB Approved Products and competency and training of Installers Technical site inspection based assessment scheme.
13 Summary of LPS 1500 Applications 1 Processing 3 Companies approved Technical issues 1. Distance the panels can be unsupported or unrestrained 2. Fire break at wall and soffit 3. Door installation 4. Penetration details
14 LPS 1531 LPS 1531 Issue 1.0 Requirements for the LPCB Approval and Listing of companies installing or applying passive fire protection products This standard defines the requirements for companies installing or applying a generic range of passive fire protection products
15 LPS 1531 Installer scheme specifically for the installation of the following passive fire protection products or systems. Appendix: 1. Penetration, cavity barriers and linear gap seals 2. Fire rated board and cladding to structural elements 3. Intumescent coatings to structural elements 4. Fire rated spray materials 5. Fire rated ductwork systems 6. Fire resisting dampers 7. Fire resistant compartment wall systems 8. Offsite application of intumescent coatings to structural elements
16 Fire Stopping Allowing for new cables? Missed out floor penetration
17 Fire Stopping Channel or stud framing missing?
18 Fire Stopping How do you fire stop this?
19 Fire Stopping Patress seals? Use of Foam fillers? Fire curtains with dampers?
20 Intumescent coatings Exposed external steel balcony What went wrong?
21 Intumescent coatings on-site application Brush applied too thick High Humidity & low temp Water damage
22 Intumescent coatings offsite application Off-site intumescent touch up and damage repair
23 Summary of LPS 1531 New Approach to Schemes for the Installers of Passive Fire Protection. Installers will self certify their work with an LPCB Certificate of Conformity Improved standards of passive fire protection product installation Site surveillance inspection of up to 15% of installations. Technical site inspection based assessment scheme.
24 Summary of LPS 1531 Applications Processing 4 Approved 33 Technical issues 1. Fire rated damper installation. 2. Framing out penetrations in drywalls 3. Use of PU foams
25 LPS 1197 Service and Maintenance of Doors Maintenance contractors LPS1197: Issue 3.0 Requirements for the LPCB Approval and Listing of companies Undertaking the Maintenance and Repair of Doorsets, Shutters and Active Smoke/Fire Barriers LPCB approved maintenance contractors who repair and maintain firedoors and shutters are approved in accordance with LPS1197. Fire doors (Maintenance and repair) LPS 1197 Fire shutters (Maintenance and repair) LPS 1197 Smoke barriers (Maintenance and repair) LPS 1197
26 Summary of LPS1197 Applications Approved 12 Technical issues None to report Ensure performance criteria are met.
27 LPS 1271 Fire and Security Door Installers Installation contractors LPS1271: Issue 1.0 Requirements for the LPCB Approval and Listing of companies installing fire and security doorsets and shutters and smoke barriers LPCB approved maintenance contractors who repair and maintain firedoors and shutters are approved in accordance with LPS1271. Fire doors (Installation) LPS 1271 Security doors (Installation) LPS 1271 Fire shutters (Installation) LPS 1271 Smoke barriers (Installation) LPS 1271
28 Summary of LPS1271 Applications Processing 2 Approved 9 Technical issues None to report Ensure performance criteria are met
29 Fire doors
30 Fire door testing
31 Fire resistant shutters
32 BRE Passive inspection service An independent third party site inspection can: Provide confidence to all interested parties that the Passive Fire Protection has been installed correctly and in accordance with the manufacturers recommendations. Confirm that the choice of products is suitable for the application. Ensure that the workmanship is of a standard that ensures the fire protection will meet the design specification. Inspection is best carried out at an early stage during installation thus enabling the sub-contractor to have the opportunity to rectify any problems rather than impact on the critical path of the construction.
33 Thank you for your attention BRE Global answering the needs of the market Ian Stewart Passive installer scheme manager September 2011
Loss Prevention Standard
Loss Prevention Standard : ISSUE 3.0 Requirements for the LPCB Approval and Listing of Companies Undertaking the Maintenance and Repair of Doorsets, Shutters, and Active Smoke/Fire Barriers This standard
More informationThe risk assessment of fire damper installations
The risk assessment of fire damper installations June 2010 Paul White OVERVIEW OVERVIEW The purpose of this presentation is to highlight that fire dampers form a key part of the passive fire protection
More informationIntroduction to cable fire stopping
Introduction to cable fire stopping Duncan Alabaster Technical Director of PFC Corofil Effects of major fire damage on businesses 6% are sold or merged 23% fully operational again after one year 43% never
More informationFire and Security Products and Services
www.redbooklive.com Fire and Security Products and Services Making LPCB Approval work for you Not all fire and security products and services on the market can be trusted in the event of a fire or attempted
More informationASFP Ireland - Fire Safety Certification. Colin Keeley Senior Site Inspector & Training Officer 22 nd September 2011
ASFP Ireland - Fire Safety Certification Colin Keeley Senior Site Inspector & Training Officer 22 nd September 2011 Fires can be devastating with serious consequences Fires in Ireland Irish Fire Service
More informationFire 2This Technical Bulletin has been commissioned by the UK SIP Association in
REV 1-12.12.11/TB002 Technical Bulletin Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in conjunction with TRADA Technology and is intended to provide the reader with introductory
More informationPassive Fire Protection Guidance for the Fire Risk Assessor. Niall Rowan Technical Officer Association for Specialist Fire Protection
Passive Fire Protection Guidance for the Fire Risk Assessor Niall Rowan Technical Officer Association for Specialist Fire Protection ASFP has just completed a guide on what to look for when undertaking
More informationCERTIFICATE OF APPROVAL No CF 5055 ARABIAN VERMICULITE INDUSTRIES
CERTIFICATE OF APPROVAL No CF 5055 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of 1 st Industrial Area,
More informationModuSec. Secure and efficient IT room solutions. Turnkey Modular Construction Fast clean build to any size or shape
ModuSec Secure and efficient IT room solutions Turnkey Modular Construction Fast clean build to any size or shape Room in room Standalone external build Transportable Modusec SR Options Modusec SR Options
More informationComposite Panel Firewall Systems
Composite Panel Firewall Systems part of the Protecting more than your business Insulated mineral fibre panels have excellent thermal and acoustic properties, ideal for factory and office partition walls.
More informationGENERAL FIRE SAFETY TERMS & DEFINITIONS
UCL Fire Technical Note - TN006 Fire Safety Technical Guide GENERAL FIRE SAFETY TERMS & DEFINITIONS Reference: BS4422-2005 Fire Safety Vocabulary - for further information and definitions BS EN ISO 13943-2000:
More informationGuidance on loft conversions in two-storey houses
Guidance on loft conversions in two-storey houses Technical guidance for building control surveyors, designers and installers 01 Guidance on loft conversions in two-storey houses Technical guidance for
More informationFire Doors Explained. Presented by - Peter Barker
Fire Doors Explained Presented by - Peter Barker Objectives and Outline 1. The role of fire resisting doors 2. Proving the performance of fire resisting doors 3. Common problems and solutions The Role
More informationCode of Practice for fire resisting metal doorsets
COP 1005 Code of Practice for fire resisting metal doorsets Scope The aim of this document is to provide guidance on the best practice for, and a better understanding of, hinged or pivoted fire resisting
More informationAssociation of British nsurers LPC. A Code of Practice for the Protection of Business
Association of British nsurers THE LPC DESIGN GUIDE for the FIRE PROTECTION of BUILDINGS LPC A Code of Practice for the Protection of Business Each year in the UK there are losses of over 1 billion as
More informationLoss Prevention Standard
Loss Prevention Standard LPS 1581: Issue 2.1 Requirements and tests for LPCB approval of nonload This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for information
More informationHow To Comply With The Loss Prevention Certification Board
Loss Prevention Standard LPS 1014: Issue 5.3 This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for information purposes only. Its use for testing, assessment,
More informationThis handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.
Basement Finishing Guide Community Development Department Building Inspections Division 5200 85 th Avenue North / Brooklyn Park, MN 55443 Phone: (763) 488-6379 / Fax: (763) 493-8171 6/15 www.brooklynpark.org
More informationFire Protection Of Ventilation Systems DAMPERS & AIR TRANSFER GRILLES A PRESENTATION BY PHILLIP HORTON OF FIRE ENGINEERING SOLUTIONS
Fire Protection Of Ventilation Systems DAMPERS & AIR TRANSFER GRILLES A PRESENTATION BY PHILLIP HORTON OF FIRE ENGINEERING SOLUTIONS THE AIM OF THE WORKSHOP: Provide assistance in the selection, installation
More informationFIRE RISK ASSESSMENT COMPETENCY COUNCIL
FIRE RISK ASSESSMENT COMPETENCY COUNCIL Competency Criteria for Fire Risk Assessors Version 1 Published : 21/12/11 Page 1 Foreword Fire safety legislation requires that, for most premises except private
More informationServices Enclosures and Protected Shafts - Maintaining Compartmentation
Introduction When a fire resisting element is used to provide fire compartmentation, every opening that allows services to pass through the element must be adequately protected by sealing, or fire stopping
More informationExcerpts from the Canadian National Building Code (NBC)
Excerpts from the Canadian National Building Code (NBC) Reproduced here with Permission of the Copyright Owner, the National Research Council of Canada, Institute for Research in Construction. For more
More informationPassive Fire Protection
Firestopping Passive Fire Protection FS20 Firestop Compound 6 hour fire rated penetration seals for electrical and mechanical services FS20 Firestop Compound FS20 Firestop Compound is a Fire-Rated Penetration
More informationRESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS
RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS The following guidelines are intended to assist with the permit acquisition process with regard to Plumbing Alterations. Not all information, or additional
More informationUPP Residential Services Fire Risk Assessment
UPP Residential Services Fire Risk Assessment TS11151-R02-DRAFT1 15 August 2011 for: Keynes College University Road Canterbury Kent Recommended latest review date 14 August 2011 Executive summary This
More information- 5 - Table1. Maximum Compartment Volumes
- 5 - Part II - SPECIFIC REQUIREMENTS 5. Compartmentation 5.1 Every building should be divided into compartments by walls and floors to inhibit the spread of fire. 5.2 Compartment walls, compartment floors,
More informationDecree of the Ministry of the Environment on fire safety of ventilation systems
THE NATIONAL BUILDING CODE OF FINLAND MINISTRY OF THE ENVIRONMENT Housing and Building Department Decree of the Ministry of the Environment on fire safety of ventilation systems Adopted in Helsinki, 18
More informationIFE Level 4 Certificate in Fire Science and Fire Safety (HL)
IFE Level 4 Certificate in Fire Science and Fire Safety (HL) Unit 2: Fire Safety Unit Reference Number: D/505/5932 Introduction This unit focuses on the prevention and detection of fire in premises and
More informationQueensland Development Code Mandatory Part 6.1 Commissioning and maintenance of fire safety installation
Queensland Development Code Mandatory Part 6.1 Commissioning and maintenance of fire safety installation Guideline A guide to assist with achieving compliance with the Building Act 1975 and the Building
More informationFIRESTOPPING & SMOKE SEALS
SPECIFICATION SECTION 07 84 00 FIRESTOPPING & SMOKE SEALS 1 GENERAL 1.1 SECTION INCLUDES 1.1.1 Comply with Division 1, General Requirements and Documents referred to therein. 1.1.2 It is the intent of
More informationELECSA and the Fire Industry
ELECSA and the Fire Industry Guide to Fire Protection and Fire Risk Assessment schemes www.elecsa.co.uk 80% Black 100% Black Section 1: What are the opportunities in the Fire Industry? Regulation of the
More informationFire safety in timber buildings
Fire safety in timber buildings Introduction Fire spread in buildings is a risk to life safety for which the Building Regulations (for England and Wales 1,2, Scotland 3 and Northern Ireland 4 ) aims to
More informationProperty Accreditation Standards 2014/2015
Property Accreditation Standards 2014/2015 Promoting responsible renting of student housing in the city of Southampton Letting period 1st July 2014 to 30th June 2015 Version 1, 10/12/2013 All properties
More informationHOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663)
HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: 1-800-TEC-WOOD (832-9663) Fire-Retardant-Treated Wood Framed Wall Assemblies GENERAL INFORMATION Fire-resistant construction
More informationEnsuring Best Practice for passive fire protection in buildings
Ensuring Best Practice for passive fire protection in buildings I am pleased to introduce to you the Guidance Document from the Department of Trade and Industry sponsored Partners in Innovation project
More informationLoss Prevention Standard
Loss Prevention Standard LPS 1181: PART 1: ISSUE 1.1 Series of Fire Growth Tests for LPCB Approval and Listing of Construction Product Systems Part One: Requirements and Tests for Built-up Cladding and
More informationFire Safety Requirements for Child Care Centre
Fire Safety Requirements for Child Care Centre A. Restrictions on Location Child care centre shall not be located : - (a) (b) in any premises designed for residential use; in any industrial building, warehouses,
More informationCertification of construction products - Fire dampers. Certification Rules 032
Certification of construction products - Fire dampers Certification Rules 032 1 Contents Contents 1 0 Preface 1 1 Scope and intended application 2 2 Technical requirements 2 2.1 Properties 2 2.1.1 Protection
More informationFire Stopping and Penetration Seals for the Construction Industry SECOND EDITION
Fire Stopping and Penetration Seals for the Construction Industry SECOND EDITION Fire Test Study Group 1 INTRODUCTION The (ASFP) was formed in 1976. The objectives of the Association are to encourage,
More informationDesign, Build and Refurbishment of Food Manufacturing Premises: An Insurer s View. mark.newton@uk.royalsun.com 020 8881 7111 07785 710668
Design, Build and Refurbishment of Food Manufacturing Premises: An Insurer s View mark.newton@uk.royalsun.com 020 8881 7111 07785 710668 Types of Insurance Property Material damage Business interruption
More informationManaging Trade Contractors for High Performance Homes. Carl Seville
Managing Trade Contractors for High Performance Homes Carl Seville Overview Implementing Management Systems Why How Steps Troubleshooting Successes High Performance Buildings Attention to detail Management
More informationFire-Rated Glass and Glazing START
Fire-Rated Glass and Glazing START www.pilkington.com/fire Fire-Rated Glass and Glazing Pilkington Fire Protection Glass North America 946 Kane Street, Suite A Toledo, OH 43612 Provider Number: J200 Course
More informationAsbestos in the home. www.tworivershousing.org.uk. for you - for your community - not for profit
Asbestos in the home www.tworivershousing.org.uk for you - for your community - not for profit Facts about asbestos, where it may be used and what to do if you find it. Introduction This leaflet addresses
More informationPreventing arson in buildings
Preventing arson in buildings More than half of fires in commercial buildings are started deliberately. These maliciously started fires can be particularly dangerous because they often develop quickly,
More informationBuilding Control Guidance Note
Issued 01/10/10 Rev Page 1 A new updated version of Approved Document B comes into force from the 6 th April 2007. This revised guidance is split into two separate documents:- Volume 1 Dwelling Houses
More informationISO IEC 27002 2005 (17799 2005) INFORMATION SECURITY AUDIT TOOL
9.1 USE SECURITY AREAS TO PROTECT FACILITIES 1 GOAL Do you use physical methods to prevent unauthorized access to your organization s information and premises? 2 GOAL Do you use physical methods to prevent
More informationSolar Panel Installations
Solar Panel Installations Page 1 of 6 SINGLE-FAMILY RESIDENTIAL CHECKLIST City of Hayward Development Services Department Revised: 7-09-15 PERMIT REQUIREMENTS Permits are required for all solar panel installations.
More informationRequirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**
PHRC Webinar Series Tuesday, September 9, 2014 1:00 pm Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited** Presented by: Bryan Heitzmann Credit(s) earned on completion of
More informationProperty Services information sheet - number 3. Asbestos. December 2008 rev 1. You may have materials that contain asbestos in your house.
Property Services information sheet - number 3 Asbestos December 2008 rev 1 You may have materials that contain asbestos in your house. A. What is asbestos B. What do you do if you have asbestos in your
More informationASFPI Fire Compartmentation Seminar
ASFPI Fire Compartmentation Seminar David O Reilly TIFireE Operations Officer Association for Specialist Fire Protection in Ireland Republic of Ireland Branch Council Member Institution of Fire Engineers
More informationPartitioning & Ceiling Product Information
Partitioning & Ceiling Product Information tel + 44 (0) 1384 412448 fax + 44 (0) 1384 4494 email enquiries@drywallsteelsections.co.uk web www.drywallsteelsections.co.uk tel + 44 (0) 1384 412448 fax + 44
More informationManagement of Asbestos. Darren Arkins Senior Inspector Occupational Hygiene Unit Chemical Business Services Division
Management of Asbestos Darren Arkins Senior Inspector Occupational Hygiene Unit Chemical Business Services Division Getting it Wrong! Asbestos What is it? With the Naked Eye! Naturally occurring silicates
More informationHow To Write A Fire Risk Assessment
Fire Safety Risk Assessment This form is to aid you in carrying out a fire safety risk assessment of a property. The form is separated in to two parts: Part 1 initial assessment form and guidance notes
More informationTECHNICAL RECOMMENDATION
TECHNICAL RECOMMENDATION NO: 9 DESIGN OF LIGHT TIMBER FRAMED WALLS AND FLOORS FOR FIRE RESISTANCE Peter Collier Contents Design of Light Timber Framed Walls and Floors for Fire Resistance Relevance Acceptance
More informationHVAC INSTALLATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings
SUCCESS WITH 2012 IECC DELAWARE Recommended Practices for Optimized Energy Savings for Builders & Trades COPYRIGHT 2015 ADVANCED ENERGY. ALL RIGHTS RESERVED VERSION 2015.1.0 CHECKLIST: JOB READY 1. 2.
More informationFIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS
INFORMATION PAPER IP 21/10 FIRE PERFORMANCE OF STRUCTURAL INSULATED PANEL SYSTEMS Tom Lennon and Danny Hopkin The use of Structural Insulated Panel (SIP) systems in construction in the UK has increased
More informationHVAC INSTALLATION. Success with 2015 IECC Northeast & Mid-Atlantic. Checklist for Builders & Trades
Success with 2015 IECC Northeast & Mid-Atlantic Checklist for Builders & Trades COPYRIGHT 2015 ADVANCED ENERGY. ALL RIGHTS RESERVED TEMPLATE 2015.1.0 PAGE 1 CHECKLIST: JOB READY 1. 2. 3. 4. 5. 6. 7. 8.
More informationWatermist fire suppression systems for commercial low hazard occupancies
Watermist fire suppression systems for commercial low hazard occupancies Watermist fire protection systems are fire suppression systems that have emerged as an alternative fire safety solution for specific
More informationModuSec. Secure and efficient IT room solutions Composite Panel Systems Compared. Panel Systems are not all the same!
Secure and efficient IT room solutions Composite Panel Systems Compared Panel Systems are not all the same! When it comes to accommodating critical IT systems, the first issue to look at is the environment
More informationFire Barriers & Fire Stopping
Presented by: Bill Lauzon, PE Lauzon Life Safety Consulting, LLC 262-945-4567 Lauzon.lsc@gmail.com Web: Lauzon-LSC.com Environmental Part 2 Life Safety Code Chapter 8 Fire Barriers & Fire Stopping 1 Fire
More informationLee Baron FIRE RISK ASSESSMENT
FIRE RISK ASSESSMENT, 13/21 Cantelupe Road, East Grinstead Prepared for: Lee Baron 7 Swallow Place Oxford Circus London W1B 2AG Prepared by: Violet McIntyre CMIOSH William Martin Compliance Solutions Limited
More informationThe Danish Enterprise and Construction Authority to inspect CE marking of windows and pedestrian doors
23. december 2010 The Danish Enterprise and Construction Authority to inspect CE marking of windows and pedestrian doors The Danish Enterprise and Construction Authority s market surveillance of construction
More informationFire precautions in dwellings. Private sector housing Providing homes building communities
Fire precautions in dwellings Private sector housing Providing homes building communities Version 3 Published by Norwich City Council August 2011 Contents Page Introduction 1 2 Types of dwellings (A) Shared
More information07 21 19 Guide Specification STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM
07 21 19 STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM 7819 Broadview Road Cleveland, OH 44131 800-522-4522 February, 2011 SPEC NOTE: This guide specification is intended for use when specifying
More informationKnauf Aquapanel Interior. Tile Backing. Cement board for wet areas. Will not deteriorate in water. Easy to score and snap
Tile Backing Will not deteriorate in water Easy to score and snap Resistant to mould and mildew Knauf Aquapanel Interior Cement board for wet areas Knauf Aquapanel Interior Cement Board Drywall for Wet
More informationThe terms hazard and risk are often used, which we define as the following:
Fire Safety Last updated in October 2010 This information sheet aims to give safety reps a basic understanding of fire safety and fire risk assessments under the current law. More detailed information
More informationSECTION 07 21 16 - PRE-ENGINEERED BUILDING BLANKET INSULATION
PROJECT ARCHITECT RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
More informationFIRE AND SMOKE PROTECTION FEATURES
CHAPTER 7 FIRE AND SMOKE PROTECTION FEATURES SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials, systems and assemblies used for structural fire resistance and fire-resistance-rated
More informationCode Requirements for Existing Buildings
Code Requirements for Existing Buildings Kevin S. Hastings, P.E., LEED AP R. W. Sullivan, Inc. 529 Main St., Suite 203 Charlestown, MA (617) 523-8227 www.rwsullivan.com R.W. Sullivan Engineering (RWS)
More informationFIRE-RESISTANCE-RATED CONSTRUCTION
CHAPTER 7 FIRE-RESISTANCE-RATED CONSTRUCTION SECTION 70 GENERAL 70. Scope. The provisions of this chapter shall govern the materials and assemblies used for structural fire resistance and fire-resistance-rated
More informationBuilding Code Clarifications - 7. Fire Resistance
Building Code Clarifications - 7. Fire Resistance 7.1 (15-12-030) Use of combustibles in Type III construction roof assemblies Code Section (15-12-030) Use of Combustibles was revised on May 17, 2000,
More informationThe Role of Fire Doors. BWF-Certifire Fire Door and Doorset Scheme
The Role of Fire Doors BWF-Certifire Fire Door and Doorset Scheme Fire doors today s agenda 1. Fire doors are essential in passive fire protection A requirement in compartmenting a building Protecting
More informationFire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1
Fire Protection Program Of Chashma Nuclear Power Generating Station Pakistan Atomic Energy Commission 5/28/2015 1 Nuclear Power in Pakistan Nuclear Power Plants Capacity (MWe) Year of Commissioning In
More informationINTERNATIONAL FIRE PROTECTION
An MDM PUBLICATION Issue 39 August 2009 www.mdmpublishing.com INTERNATIONAL FIRE PROTECTION THE GLOBAL VOICE FOR PASSIVE & ACTIVE FIRE PROTECTION Progress with fire-resistant glass Limiting risk, reducing
More informationFiberglas, Exterior Wall Thermal Insulation
PROJECT ENGINEER RESPONSIBILITY: This is a general specification guide, intended to be used by experienced construction professionals, in conjunction with good construction practice and professional judgment.
More informationEuropean Technical Approval ETA 13/0526
European Technical Approval ETA 13/0526 Trade Name Holder of the approval Website Generic type and use of construction product DOLCEA i3 PCIM S.A. Rue du Péquet 54 5590 Achene (Ciney) Belgium www.isoproc.eu
More informationProject Close Out Summary
Project Close Out Summary 1. Final Cleaning and Inspection 2. Testing and Certification 3. Demonstration of Systems and Equipment 4. Inspections by Authorities Having Jurisdiction 5. O&M Manuals and As
More informationInstallation Details. D1 General D2 Walls D3 Ceilings D4 Reference. D Installation Details
D Installation Details D1 General D2 Walls D3 Ceilings D4 Reference D Installation Details D Contents D1 General Installation and Fastening Sequence for Steel Studs D1.1 Fastener Selection D1.3 D2 Walls
More informationArt Basel Miami Beach Dec 3 6 2015 Booth Design Regulations
1 6 1 BOOTH CONSTRUCTION The Art Basel in Miami Beach form an integral part of the contract between the exhibitor and Art Basel U.S. Corp. (see Art Basel in Miami Beach Exhibition Regulations). The following
More information*Trademark of The Dow Chemical Company A business unit of The Dow Chemical Company and its subsidiaries Copyright 2003 The Dow Chemical Company.
Dow Chemical is a Registered Provider with The American Institute of Architects Continuing Education Systems. Credit earned on completion of this program will be reported to CES Records for AIA members.
More informationFire doors guidance. Safety and Health Services. Document control information. Date issued: January 2011. Version: 2. Previous review dates: 2011
Document control information Fire doors guidance Published document name: Firedoors-gn.pdf Date issued: January 2011 Version: 2 Previous review dates: 2011 Next review date: Related documents: Governing
More informationPolicy for the Management of Asbestos in the Workplace
Southwark Council Management of Asbestos in the Workplace November 2011 Page 1 of 15 CONTENTS 1. INTRODUCTION... 3 2. POLICY STATEMENT... 3 3. ASBESTOS RISK CLASSIFICATION SCHEME... 5 4. SAMPLING OF ASBESTOS
More informationFireWall. High performance fireresistant. FireWall. www.british-gypsum.com
FireWall FireWall High performance fireresistant wall system FireWall is a non-loadbearing wall which provides up to 240 minutes fire resistance. It is used in certain ground floor basement situations
More informationEuropean Organisation for Technical Approvals
Warrington Certification Limited, Holmesfield Road, Warrington, WA1 2DS Tel. +44 (0) 1925-646777 Fax +44 (0) 1925-646667 Member of EOTA Authorised and notified according to Article 10 of the Council Directive
More informationFire Doors The Role of a Fire Door
Fire Doors The Role of a Fire Door BWF-Certifire Fire Door and Doorset Scheme Presented by John Fletcher John Fletcher Consulting Ltd. Fire doors main messages 1. Fire doors are essential in passive fire
More informationMarch 14, 2007. Installation of Bay, Bow and Garden Windows
March 14, 2007 Re: Installation of Bay, Bow and Garden Windows Attached are the Atrium Companies, Inc recommendation for the installation of bay, bow and garden windows. These instructions were developed
More informationThe Pennsylvania State University ------------- Physical Security Office. Intrusion Alarm. Performance Specification
The Pennsylvania State University ------------- Physical Security Office Intrusion Alarm Performance Specification By PHYSICAL SECURITY OFFICE Group (Access Controls & Electronic Security Programs) and
More informationFIRE SAFETY INSPECTION REPORT
FIRE SAFETY INSPECTION REPORT SINCERE KNIT GARMENTS LTD UNIT-1 EAST ISDAIR, CHANDMARI, FATULLAH OTHER FACTORIES: FAKIR KNIT LTD. July 20, 2014 Page 2 SUMMARY was surveyed for fire safety on 7/20/2014 by
More informationContents. APA Construction Details. Full fill cavity walls 2-13. Partial fill cavity walls 14-25. Solid externally insulated walls 26-37
Contents Pages Full fill cavity walls 2-13 Partial fill cavity walls 14-25 Solid externally insulated walls 26-37 Appendix (BRE confirmation of Ψ and y-values) 38-40 Page 1 of 40 APA Construction Details
More informationFACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST
FACILITY FIRE PREVENTION AND EMERGENCY PREPAREDNESS INSPECTION CHECKLIST Date of Inspection: Conducted by: Location: Reviewed by: Date of Review: Comments or additional corrective action taken as a result
More informationCERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011
CERTIFICATE NAME OF PRODUCT No VTT C-6044-10 Date of issue 11.10.2010, Updated July 1, 2011 H-CONTROL REFLEX+ reflective insulating vapour control layer for roof and wall applications MANUFACTURER ACTIS
More informationwww.bre.co.uk Security systems Protecting people and property
www.bre.co.uk Security systems Protecting people and property The correct specification of security products and systems is critical in protecting people and property from losses associated with crime
More informationAvoiding Air Barrier Pitfalls
Avoiding Air Barrier Pitfalls Design & Durability November 2013 Air barriers, when correctly installed, help buildings achieve high levels of energy efficiency by decreasing heat loss. For example, great
More informationC05. S03. P02 P08 FireWall. Including C05. S01. P02 Specialist partitions introduction
C05. S03. P02 P08 Including C05. S01. P02 Specialist partitions introduction C05 Specialist partitions Introduction Specialist partitions This section details specialist lightweight systems where high-security,
More informationFIRE RATED GLAZING System Guide
SYSTEM GUIDE Issue date: 05-05-2015 Expiry date: 31-12-2016 System Guide Introduction Pyropanel Developments are specialists in fire rated glazing solutions, and our systems are designed for easy installation
More informationNew Ontario Building Code Requirements for Mid-rise Wood Frame Buildings
New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings Note: This information addresses complex issues in a summary fashion. Consideration should be given to the official version of the
More informationISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK. Website www.iomfire.com
ISLE OF MAN FIRE & RESCUE SERVICE FIRE PRECAUTIONS LOGBOOK Website www.iomfire.com ADDRESS OF PREMISES FIRE CERTIFICATE No. (where applicable).. LOCATION OF LOG BOOK. CONTENTS OF LOG BOOK Useful telephone
More informationAVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839
AVAILABLE TO DOWNLOAD ON THE APOLLO APP a guide to Fire Alarm Systems Design BS5839 Part1:2013 The Regulatory Reform (Fire Safety) Order (FSO) became law on 1 October 2006 Legally you must comply! What
More information