U N D E R G R O U N D C A B L E S



Similar documents
GUIDELINES FOR UTILITY INSTALLATIONS Part 1 - Wire Lines and Communications Cables

CHAPTER VIII LINE PLANT SYSTEM COMMUNICATION THROUGH RE CABLE

EARTHING AND BONDING AT SECONDARY SUBSTATIONS

Preamble To Schedule A

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

For business. Wiring your business for broadband. What happens when copper is required?

Trial Exams C. Standards and Regulations. Examination No: GH-08-C- 1 hour and 5 minutes plus 10 minutes reading time

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE

TS 813 GROUNDING AND BONDING TTD TRAFFIC SIGNAL INSTALLATION AND CONTROLLER CABINET GROUNDING SYSTEM TTD CONTROLLER CABINET GROUNDING

SECTION SIGNAL WIRE AND CABLE

Operating Instructions

INDOOR PHONE INSTALLATION (CONCEALED) TECHNICAL SPECIFICATION

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND TELECOMMUNICATION CABLES IN THE VICINITY OF TRANSPORTATION FACILITIES

Operating Instructions

Aerial Fibre Optics. Complete One Stop Solution for Aerial Fibre Optics. OPGW Cable and Fittings for OPGW

Specifications for Lightning Protection. ASAE Engineering Practice

Underground Service Requirements and Instructions

Underground Commercial Electric Service

ELECTRICAL SERVICE REQUIREMENTS FOR MOBILE HOME DEVELOPMENTS

Requirements for the Attachment of Communication Cable Facilities on PPL Poles

Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

800 Communications Circuits

Optical Cable Pre-Construction Survey. Keywords Stationary Reel Method, empty innerducts, sub-ducts, microducts, Intermediate-feed manholes

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

PRIMARY SERVICE LINE: The Company's conductors which connect the supply line with a transformer located on private property.

EH-20 20m antenna. By VE3RGW

CONTENTS. Yale University Design Standards. Underground Electrical Duct Bank. A. Summary. B. System Design and Performance Requirements

TC Grounding and Bonding for Telecommunications Systems

Electric Engineering Division FIBER CONDUIT RULES AND REGULATIONS

Session 14 Cable Support Systems

Gas Meter Clearances and Service Installation Requirements

Town House Center Highway North Huntingdon, PA 15642

FACTORY AUTOMATION. Manual Laying loops for Loop detector LC10-1 and LC10-2

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

ELECTRICAL SAFETY Information Bulletin

Unarmored Variable Frequency Drive (VFD) Cable Termination Guide

12 Appendix 12 Earth Electrodes And Earth Electrode

Network Standard Advice No. 1420C 9/6/2011

Single Channel Loop Detector

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

COMMERCIAL CONDUIT RULES AND REGULATION

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

RZ Guardrail System Installation Manual

Please check with your local inspection authority for any additional requirements before installation.

How To Get A Power Line Extension

Gulf Cable & Electrical Ind. Co.

BLUE RIBBON CORP. BC001 Birdcage Installation Manual

Safe & Sound Bridge Terminology

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

AC and DC Drive System Installation Information

Chapter 9. Bonding and Grounding

BUILDERS AND CONTRACTORS GUIDE FOR ELECTRIC SERVICE

Interface between Eircom Network and Additional Telephone Equipment

Fault location on power cables. Fault location on power cables

FAQ s on Siemens Magmeters

Protection Systems. A UTC Fire & Security Company F Linear Heat Detector FEATURES DESCRIPTION APPLICATIONS BENEFITS

Design of Bridges. Introduction. 3 rd to 4 th July Lecture for SPIN Training at the University of Dar es Salaam

METER REQUIREMENTS GENERAL REQUIREMENTS SECTION D

CHAPTER 8 CIVIL DESIGN

Unit Price Averages Reports

Presenters Brett Weiss, Gabe Martinez, Brian Kroeger.

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Residential Deck Safety, Construction, and Repair

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

OVR-3SP Recloser with PCD Control Style Guide 1VAL SG March 30, 2009 Revision B

BUILT-IN DISHWASHER INSTALLATION INSTRUCTIONS

ARTICLE II (2) ARTICLE II - REQUIRED USE OF PUBLIC SEWERS. PARAGRAPH Purpose and Application.

Guide to working on Public Sewers

Standards. 5 ANSI/TIA/EIA-569-A (CSA T530)

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

Minimum Standards for Data/Voice Infrastructure in New Building Construction

CP2 Buried Cable Pedestal Initial & Rehab Installation Instructions

Hanna delivers the technical and marketing expertise needed to produce a car wash that meets the car wash customer's expectations.

Recommendations for Marking Communication Facilities with Use of 3M EMS Electronic Markers

1 Campus Cabling Systems Introduction

CUSTOMER REQUIREMENTS AT POWER SUBSTATIONS

AERIAL FIBER OPTIC CABLE PLACEMENT

CONSOLIDATED EDISON CO. OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING DEPARTMENT SUBSTATION & EQUIPMENT SECTION

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

Policy and Guidelines for Electric Service

DIVISION 26 - ELECTRICAL SECTION CABLES FOR INSTRUMENTATION

Undergrounding high voltage electricity transmission. The technical issues

HOUSTON COMMUNITY COLLEGE HCC ALIEF CAMPUS MAIN BUILDING, FIRST, SECOND & FOURTH FLOORS RENOVATION ISSUE DATE:

REQUIREMENTS AND SPECIFICATIONS FOR HIGH VOLTAGE CUSTOMER BUILT FACILITIES PEPCO ENGINEERING

The electrical energy produced at the gen

FAQs-Main switchboard design criteria

Table of Contents. Inductive Loop Vehicle Detector Applications

INSTALLATION GUIDELINES for SOLAR PHOTOVOLTAIC SYSTEMS 1

CONSTRUCTION STANDARD ELECTRIC OPERATIONS ORGANIZATION

The Basics of Loop Vehicle Detection

CTI TECHNICAL BULLETIN Number 9: A publication of the Cable Tray Institute

Visage. Digital. Digital diverter. Installation guide. Visage Digital diverter installation instructions Page 1

WIRE, TERMINAL AND CONNECTOR REPAIR CONDUCTORS

Transcription:

PIJF CABLE U N D E R G R O U N D C A B L E S Telecom Cables Require Protection:- From probable mechanical damages From water and chemical or soil condition From digging by different agencies From damages while handling Advantages of PIJF Cable Counting of Pairs easy Jointing easy, No chamber required Failure of Joint is less Entry of moisture is prevented Can be directly terminated to MDF/Pillar/DP etc Handling easy Life is more. Design of Cable Conductors Core Moisture Barrier Screen Sheath ( PVC ) Bedding Armouring Jacket. CODE FOR CONDUCTOR INSULATION Identification and Length markings on a Cable 1. Telephone handset emblem 4. Capacity of the cable in pairs 2. Name of the Manufacturer 5. Size of the conductor 3. Year of Manufacture 6. Length marking

Surveying The route should be as short as possible Normally laid along road and Railway Tracks Corrosive soil should be avoided Opening expensive pavements and roads should be avoided Consideration given to the existence, alteration and growth of services Proper co-ordination with other underground services like Water, Electricity, Sewage, Gas etc Permission for Digging From Municipal or Local Authorities Traffic Authorities Highway Authorities Railway Department Port Trust Authorities Co-ordination to be maintained Electric Supply Water supply Gas Pipeline Sewage system Construction practice (Cable Laying) Classified in to:- Receipt, Storage, Handling and Transport Surveying and selection of route Trenching and Laying Jointing of Cable & Termination Preparation of Cable Plan, Cable diagram and other records Acceptance Testing. 2

LAYING METHODS There are three methods normally adopted:- 1. Laying direct in the ground 2. Laying solid 3. Drawing through Duct / Duct laying. Trenching The Depth of trench should be 1.2Mts, and in any case it should not be less than 60 cms. The alignment should be straight at least 50 mts at a stretch. It should be at least 30 cms from the boundary walls. Width should be between 30 to 40 cms. A separation of 60 cms to be maintained while laying parallel to electric cables. Power Parallelism should not exceed 800 mts While crossing with Electric cables, telephone cable should be laid solid in between for 90 cms on either side The minimum-bending diameter for armoured cable should be 15 times of Diameter of the cable Road crossing Cable should be laid through G.I Pipes. The depth of pipe from the surface of road should be 1 mtr with a slope to pass water. The number of pipes should cater for 20 yrs. No Joints in the middle of the road. The trench should be reinstated with sand. Along National highways: - Cable should be laid at a distance of 457 cms from the centre of the road. Along over bridge/culvert/flyover Culverts should be paved by a concrete channel of 12 depth below the bed of the culvert While laying across small bridges Gi pipes to be clamped to and extend beyond piers for safety of cables 3

In the case of long bridges/flyovers liaison should be kept with authorities for suitable arrangements or can use concrete channel provided with removable covers at a depth of 90 cms Laying cable along Railways The trench should be at a distance more than 5.5 mts from the center of Railway track The Railway staff at the cost of BSNL should attend excavation and reinstatement within 3 mtrs Railway crossing:- Use G.I pipes of 75mm dia, and Minimum depth from rail level should be 1.25 mtrs, and the length of pipe should be sufficiently long and should not extend 4.5 meters from the center of last track. No overhead crossing permitted Crossing Culverts Use G.I Pipes cut at the ends in V- Shape on the outer surface and bend downwards so as to lead in the cable end to the trench Cable Jointing Jointing technique consists of: - 1.Conductor jointing (Uses UY Connector) For Cables more than 200 pairs jointing done by 20 pair modules 2. Protection against moisture entry Protect against corrosion & Mechanical damage Type of Jointing KITs and usage TSF 1 TSF 2 TSF 3 TSF 4 TSF 5 TSF 6 TSF 7 10, 20 Pair (straight joint) 50, 100 Pair 200 Pair 400 Pair 800 Pair 1000 Pair 1200 & Above Sequence of Joint closure 1) Cable Marking 7. Cable preparation 2) Armour continuity 8. Install sleeve 3) Conductor jointing 9. Thermo shrinking 4) Sheath continuity 10. Armour continuity completed 5) Filling compound 6) Metal canister 4

Location of Cabinet & Pillar Should be located at obstruction free place To be mounted on concrete Plinth Easily accessible Adequate space for jointing and other works Should not be in a curve, or a crowded place Should not obstruct pedestrians Avoid Marshy & Floods area Siting of Cabinets, Pillars & DP Cabinet & Pillars normally 800 and 1000 pair. DP s 3/5/10/20 pairs are available In Pillars and Cabinets CT-Boxes of terminating capacity of 100 pairs are mounted which is made up of Krone type modules of 10 numbers Krone tool is used for terminating wires. ( No stripping, No soldering, No screwing required) Leading in Distribution Cable to DP In case of external DPs, the cable is carried to DP box through GI pipe of 2 diameter. The GI pipe is fixed to the post by 2 nos of G.I clamps to hold the GI Pipe firmly. The lower end of the GI pipe should be about 30 cms below the ground surface. In case of internal DPs, the cable is lead into the building through a leading in pipe usually provided by the subscriber. Construction & Mtce of DP External DPs are fitted on posts by means of suitable size of U backs Internal DPs are fitted inside buildings on the wall at suitable location In cases of Multistoried buildings, where the telephone demand is very high the distribution cable of 20 pair or 10 pair size are taken to different floors or blocks and terminated on 10 or 20 pairs subs DPs. Individual wires are further provided from the subs DPs to the location of the telephone. 5

LOCATION OF DP ON THE POST DP should normally be fixed at minimum height of 6 feet from the ground or in cases where it is fitted still higher to avoid risk of damage or interference by unauthorized persons, its top should be 1 foot below the ultimate lowest bracket The DP is fitted to the post with the help of U backs. The cable tail is passed through the GI pipe and the pipe is pushed up so that the bottom of the DP sits on the upper end of the GI Pipe. MAINTENANCE OF CABLE RECORDS Cable records are very effective tools for the maintenance of cable networks. The cable records may be divided into three categories 1. Plan, 2. Line diagram and 3. cards. PLAN OR MAPS The following types of plans are generally maintained The exchange area layout map which show the following details:- Boundaries of existing exchange area Proposed boundaries of future exchanges but liable to alterations Location of existing exchanges Localities where future exchanges may be situated CABINET AND PILLAR AREA LAYOUT MAPS (xge wise) The location of the cabinets, Primary cable routes, Duct lines, Manholes etc. Location of pillar, Secondary cable route, Location of Secondary cable joints, Duct lines, Man-holes etc. Location of DPs (either internal or external) the distribution cable route, the location of joint etc. 6

LINE DIAGRAM These diagrams show the actual orientation of the cable network including the size of the joints, type and size of the DPs etc. Primary line diagram:- When the primary is laid through the duct, the diagram is named as primary duct lines diagram. It show all relevant information in respect of configuration of the primary cable, Ducts and Manholes for Primary cables. DISTRIBUTION LINE DIAGRAM This diagram represents the cable orientation for all the distribution cables emerging out of a particular Pillar One diagram is meant for a pillar and all the DPs connected to it. JUNCTION CABLE DIAGRAM This diagrams show the junction cable network in multi exchange area Drop wire Installation Drop wire normally used is two hard drawn copper cadmium conductor 1.25mm or 0.91 mm diameter laid parallel side by side and covered with black PVC of hard grade insulation. A ridge is provided between the two conductors so that they can be separated into two fully insulated conductors without any injury to the insulation of individual conductors Hardware accessories for Installation Drop wire Distribution Clamp:- It is intended for suspending the self supporting drop wires at DP s and intermediate point on poles Support clamp with U Back For supporting distribution clamp It is fixed on Channel Iron Bracket using U-Back DP CARDS These cards show the number, size, type (internal or external) and location of the DP and how each terminal of the DP is utilized. One card is required for each 10 or 20 pairs DP. 7

The cabinet and pillar cards One set of cards is required for each cabinet or pillar. The set contains one card for each 100 pair CT- box. Each card shows the following particulars:- Number,size, and type of the CT box, size of shell, location of the cabinet or pillar, Circuits working one each terminal of the CT box, The terminal to which The circuit is jumpered. The distant end code corresponding to each terminal of the CT box and the codes of cable pairs connected to the terminals. These cards must be filled in at the time of installation and subsequent additions or alterations effecting the entries must be incorporated. COMPUTERISATION OF CABLE RECORDS Objective of Cable Records Management System (CRMS) i.e. Digitization of cable records & drawings to facilitate BSNL Design & maintain a communication network model. To analyze the network model in different ways, distribute information as needed & interact with variety of enterprise systems. To manage the planning, design, construction, operation & maintenance of cable network. Development of centralized telecom database DATA INPUT TO COMPUTER The complete subscriber information has to be entered in computer, Fault control system is required to be fed to the computer in a suitable manner The complete subscriber information referred in manual fault control system is required to be fed to the computer in a suitable manner before the system can be made operation. (Information like Directory no, Address, Pillar - In/Out, DP termination, Category, VIP,PABX /CCB/STD PT etc) Numbering schemes of cabinet, pillar and DP 8

Cabinets are given two digits number in the series 01 to 20 Pillars are also given two digits numbers but in the series 21 to 99 Once the number is given to a Pillar, it must not be changed unless it is transferred to another exchange area. The verticals are numbered serially commencing from non-growing end in two digits 01 to 99. Coding of primary, secondary & Distribution cables Primary cables are given a single letter code A, B,C,D... etc. (I and O omitted) Secondary cables are coded with the cabinet number followed by single letter A,B,C,D,...etc. (Example 12 C ) The junction cable code consists of two letters denoting the exchanges at which the cable is terminated and digit denotes the serial number ( Eg:-Junction cable between City & Park exchanges are coded as CP 1, CP2, CP3...etc.) DPs are given four digit number The first two digits correspond to the number of pillar from which the DP is fed. In case of Inner zone DP the first two digit will be 00. The last two digits denote the serial number of DP with the pillar area or the inner zone 9

QUESTION _ UNDERGROUND CABLES Fill the blanks 1) The circuit between two exchanges in a local network is called.. 2).. Is the last cable termination point from where subscriber line is connected. 3) The cable connecting Pillar and DP is called 4) In ducted cable system we use.. --------------------cables 5) Entry of moisture into PIJF cables is prevented by filling.. 6) PCM cables are designed with a conductor diameter of..mm. 7) A 400 pair cable consist of. ------No of super units of.. Size. 8) while selecting the route for laying cable ------------------ ----------- route should selected. 9) While crossing power cables the telecom cables should be laid at ------ ---------- ------- to the power cables. 10) While crossing roads it should be ensure that --------------- should fall in between road crossing. 11) The bending diameter should be minimum of---------- ------- --- ---------- time the diameter of the cable. 12) The laying of telecom cables across railway crossing should be laid in -------------------- pipes. 13) The protective stone/ slabs which are placed over the cables after laying in the trench are called -------------- ---------------- and they help in preventing damages due to digging by other service utility personnel.

14) Indicator kept at 200 m apart in the route of the cable is called ------------ 15) The indicator kept at every joint place is called ------------. 16) While crossing the power cables the telecom cables should be laid in solid for a distance of ------------ on either 17) The jointing of pairs of one large size cable to two or more smaller size cables is called --------------- jointing. 18) The jointing of one cable to another cable of same size is called ------------------- jointing. 19) For jointing 100 pair PIJF cable conductors---------------- number of UY connectors are required. 20) For jointing conductors of bigger sizes of PIJF cables ------------ pair module are used. 21) Power induction in telecom lines is due to -------------- of power and telecommunication wires. 22) At the crossing of power lines, telecom wires or cables should be crossed at almost ------------------ with sufficient vertical separation. 23) The PTCC clearance is to be obtained if the length of parallelism between telecom and power lines is -------------and above. 24) The minimum vertical clearance between power and telecom line is --------. 2

25) Ensure sheath continuity at -------------- and earthing at DP pillar and MDF. 26) Ensure use of ------------------------ in the splice to avoid any possibility of ingress of moisture setting in to the joint of PIJF cables. 27) While crossing power cables the telecom cables should be laid at right angles and should be laid in -----------------------. 28) The quality of telecommunication circuit and signals are affected by the type of induction called ---------- 29) The arrangement provided above telecom lines or below the power lines to safe guard the personnel and equipment due to contact of the lines is called ---------- 30) Gas discharge Tubes are of --------------- restoring type. They come to normal position once the induced voltage drops down to with in limits. 31) CRMS stands for------------------------ 32) In case of PIJF cables ensure use of -------------- for pressing UY connectors for jointing the conductors instead of ordinary pliers to avoid break faults. 33) As far as possible a single length of drop wire should be run from -------------------------up to maximum length of four spans 34) Improper cable works and lack of Co-ordination with other public utility services result in cable ------------------------. 3

35) Elimination of ----------------------in drop wire reduces high resistance faults. Following accessories are to be used. 36) Fault Prone cables with low insulation should be -------------- All heavy overhead alignment should be --------------------by new DPs. 37) Cabinets and pillars should be installed for more than ------------ line exchanges. 38) In a local cable network where there are no cabinets and pillars then the network is called -------------------- system 39) In a local cable network where there are Pillars only then the cable connected to DP and pillar is called-------------------- cable and the cable connected to pillar and Exchange MDF is called -------------- --------- cable. 40) The size of the module used in Krone type CT Box termination of underground cables at Pillar or cabinet is -------------. 41) No soldering, no screwing and no stripping of insulation is required for termination of cable pairs on a ----------------- type of termination points 42) Service line is the portion of the ------------------------- from pole Mount DP to the terminating points. 43) Internal DP is the cable termination Point where underground cable is laid directly to the ------------------- 44) The Inspection of ---------------------- consists of the inspections carried out by checking DPs / cabinet Pillars and subscriber lines. 45) When the insulation between the earth and the conductor in test in a cable becomes very low the fault is called -------------------------- 4

46) When the insulation between conductors in the cable or between the pairs or between pair and earth falls below a prescribed limit (normally 0.5 meg ohm) the fault is called -------------------------- 47) When the Conductor is cut then the fault is called ----------------- 48) The existence of potential, even when the circuit is idle or isolated from the potential of exchange and subscriber premises equipment then the fault is called ------------------------------- 49) Bad constructional practices like in-efficient, nonstandard and careless work-man ship, specially during the time of laying & jointing of cable result in ------------------------ 50) This instrument is extensively used in all the cable maintenance sections for testing all types of faults which on Wheatstone Bridge principle is -------------------- INDICATE WHETHER TRUE OR FALSE 1. The material used as conductor in local telecom under ground cables is high conductivity annealed copper 2. The sheath of a underground cable protect the conductors from damage due to entry of moisture to safe guard the insulation resistance of pairs. 3. Jacket is the sheathing arrangement made over armoured cable to protect the armour against corrosion and rusting 4. Paper Insulated cables are now being replaced with Polythene insulated Jelly filled cables to improve efficiency of cable network 5

Write short notes A. What are the important cable record to be maintained. B. Write important features of maps and diagrams to be maintained. C. Write the details a DP card shows. D. Write the details a pillar card shows. E. Mention Three Advantages Of Computerizing The Fault Control System F. What are the points to be checked during inspection of External plant. The Points should be noted at cabinets and pillars while inspection?. 6